INDICOM 2010
News
Naming concept
Channel Browser
GigaBit support for IndiModul 622 & IndiSmart 612
Raw data streaming
Special measurement modes
Sensor Admin
Data Compression
INCA Interface
Enhancements
Copy Object Attributes
Interval Rounded
Extensions to CA Processor
8/11/2019 INDICOM 2010
3/20
3Gernot Hacker, October 2009
NAMING CONCEPT
By decision of the ITS top management the SPMTdeveloped a new concept for the AVL software Suite.This includes a naming concept as well as definition of
the life cycle of the Suite. This concept was agreed onMay 5th 2009 and is valid from this date.
The naming concept takes several boundary conditionsinto account defined by the messages that shall betransported:
Make it easy for customers to know which productsfit together
Keep value of product brands
Emphasize system approach
The name for the IndiCom version that will be releasedin October 2009 will be
AVL IndiCom 2010
8/11/2019 INDICOM 2010
4/20
4Gernot Hacker, October 2009
CHANNEL BROWSER
Channel Filter Set
Allows users to assign channel filter criteria to a set of filters and save themunder a definable name. The defined channel filter sets can be activatedquickly via the channel filter list
Data Point Filter
Via the Data Point Filter option in a datasets context menu you can filterout the data points from a long measurement that are relevant for anevaluation. This function is useful e.g. in cases where the measurementhas several curves which then need to be evaluated individually. You cannow define a filter for the data key that returns only those records from all
channels in which the value of the curve channel is 1. Data point filters areare ideally suited for control channels which contain the relevant curvenumbers (or phase, mode, cycle, etc.). It is then possible to filter by thesedata points.
Dataset Display
Datasets which are shown in any form in the current diagram window are
now marked in Channel Browser by the corresponding formatting.Modifying Graphics Attributes
Via the context auto toolbar of Channel Browser you can modify thegraphics attributes in one step in all tests and across the entire layout.Changes made at the file/test level will affect all displayed datasets of theselected test, at the channel/dataset level these will affect all displayed
datasets of the same name.
8/11/2019 INDICOM 2010
5/20
5Gernot Hacker, October 2009
GigaBit SUPPORT FOR INDIMODUL & INDISMART
The GigaBit device family is now completed withIndiModul and IndiSmart. All new devices aredelivered with IndiCom 2010. For more detailedinformation of the devices click on the pictures onthe left.
AVL IndiModul GigaBit TM
AVL IndiSmart GigaBitTM
Adobe AcrobatDocument
Adobe AcrobatDocument
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
6/20
6Gernot Hacker, October 2009
RAW DATA STREAMING
Raw Data Streaming is now available both on
a time and angle basis . This allows users toalso measure the time data in Streamingmode.
Benefits:
Parallel streaming of time- andcrankanglebased raw data
enables to perform realtime calculationof results on the PC (SoftRTP)
save time because on measurementcompletion all data have already beentransferred to the PC
new measurement solutions to recordall the necessary information
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
7/20
7Gernot Hacker, October 2009
COLD START MEASUREMENT
In this mode, normal angle-based parameters areautomatically converted internally into time values andmeasured. This way all signals involved in the cold start
process are available as time-based data which are thenalso converted into an angle-based IFile. During themeasurement, the time-based signals are plotted overangle base using a fast macro.
Benefits:
Measurement of effects happening already before firstengine rotation (e.g. battery voltage drop)
Data file with time- and crank angle based informationof all measured channels
No need of complicated time to crank angleconversion after the measurement
Online display of raw data and calculation results forfast engine start evaluation
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
8/20
8Gernot Hacker, October 2009
SIMULTANEOUS EVENT RECORDING
In this mode, if the Normal measurement mode isselected, a measurement can be saved to aseparate file after an event has occurred. This has
the advantage that the event measurement takesplace regardless of normal test bed operation.Simultaneous measurements (single-, snapshot-or PUMA measurements) are not affected by this.
Benefits:
Execution of two measurement at the sametime
Generation of separate measurement file foreasy data access
Capturing of events on cyclic basis evenduring averaged measurements takes place
Measurement 1
Event 1 Event 2 Event 3
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
9/20
9Gernot Hacker, October 2009
SNAPSHOT MEASUREMENT
In order to record events that occur suddenly, thiscan now also be triggered very simply by pressing thespace bar. This measurement is possible in all
measuring variants with Streaming and Monitoringand is independent of other measurements. Aseparate file (BackgroundFile) is created with adefinable name and path.
Benefits:
Capture of events even without defining anevent in the parameters
Measurement of unpredictable events
No disturbance of ongoing measurements
Easy data handling by saving a separate file
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
10/20
10Gernot Hacker, October 2009
MEASUREMENTS TRIGGERED VIA HARDWARE
For special applications in test bed operation ameasurement can be started via an externalsignal (e.g. via Digital In ). This enables users to
save data in sync with such an external signal.As of PUMA Open 2010 it is possible to performreal-time measurements using the function Bit-controlled measurement series .
Benefits:
Triggering a measurement via externalsurface feeler (e.g. two wheelerapplication)
Triggering of measurements via externalBits for synchronization of differentmeasurement systemsSupport for Puma 2010 real timemeasurement
Only fo GigaBit systems!!
8/11/2019 INDICOM 2010
11/20
11Gernot Hacker, October 2009
SENSOR ADMIN
The additional program Sensor Admin can be calledvia the Utilities option in the workflow bar.
Sensor Admin serves for sensor administration in anAccess database. When setting the parameters forthe amplifiers in IndiCom you can take over the
respective sensors calibration data automaticallyfrom this database.
With Sensor Admin you can add new sensors,delete old ones, make required adjustments anddisplay the sensitivity of the individual calibrations
over time as a trend.
8/11/2019 INDICOM 2010
12/20
12Gernot Hacker, October 2009
SENSOR ADMIN
8/11/2019 INDICOM 2010
13/20
13Gernot Hacker, October 2009
DATA COMPRESSION
IFiles can now be compressed automatically(xxx.zip). For this purpose, the Compress file(zip) check box under General tab underExtras | Pre-Sets Data Storage has to beactivated.
8/11/2019 INDICOM 2010
14/20
14Gernot Hacker, October 2009
INCA INTERFACE
IndiCom 2010 is fully integrated into thecalibration software INCA. The OpenHardware Interface (OHI) from ETAS is usedto communicate between IndiCom & INCA.
Benefits:
Measurement control from INCA
Data exchange from IndiCom to INCA
Synchronization of time based INCA data& crank angle based IndiCom data
Usage of IndiCom for thermodynamiconline calulation of indicating parameters
Advanced data post processing inConcerto (MDF & IFile)
Fast data check in IndiView (substitute ofMDA)
8/11/2019 INDICOM 2010
15/20
15Gernot Hacker, October 2009
INCA INTERFACE DEVICE INTEGRATION
8/11/2019 INDICOM 2010
16/20
8/11/2019 INDICOM 2010
17/20
17Gernot Hacker, October 2009
INCA INTERFACE LOAD PARAMETERFILE
8/11/2019 INDICOM 2010
18/20
18Gernot Hacker, October 2009
INCA INTERFACE CHANNEL LIST
8/11/2019 INDICOM 2010
19/20
19Gernot Hacker, October 2009
INCA INTERFACE ONLINE DISPLAY
8/11/2019 INDICOM 2010
20/20
20Gernot Hacker, October 2009
ENHANCEMENTS
Copy Object Attributes
The toolbar button Format Brush can be used to apply objectattributes (color, line width, line type, marker, label, font) of a
given object to other objects of the same type. If the userselects a target object by right-click, a context menu will openshowing a selection of the attributes to be copied. If the targetobject is selected by left-clicking it, all attributes will be copied.
Scale Range Property "Interval Rounded
The functionality Interval Rounded was reactivated for thescale range settings. By deactivating this setting it is nowpossible to define an exact scale range without causing the gridspacing to be rounded.
Extensions to CA Processor / 4CA1 CA calculator
The Double Gap Mode allows users to use double-gap disks.The Delay Compensation for Inductive Sensors function canbe used to compensate for the speed-dependent delay ofinductive sensors.