Industrial CPC TON-SCALE CANNABINOID
PURIFICATION BY CENTRIFUGAL PARTITION CHROMATOGRAPHY
Pharmaceutical Grade Purity RotaChrom has developed the most cost effective and efficient method for isolating cannabinoids to >99% purity from a crude cannabis extract.
Ton-Scale purification This industrial scale technique’s unparalleled throughput and loading capacity makes it capable of processing 500 kg input material per month on a single iCPC instrument.
rCPC
The first industrial scale CPC application
in the world.Loading Capacity:
up to 500 g Nominal flow rate:
2.5 L /min
Capacity (purified kg/Month):
up to 500 kg Dimensions (W x H x D):
4’11” x 5’11” x 4’9”Weight: 3,527 lbs
CPC is a liquid to liquid chromatographic technique, which means that both the mobile and stationary phases are liquid solvents. This highly scalable and adaptable technique is efficiently used to isolate cannabinoids, remediate pesticides or remove THC. RotaChrom offers research (r)CPC and industrial (i)CPC. RotaChrom’s iCPC is the largest CPC currently available in the world.
CPC – CENTRIFUGAL PARTITION CHROMATOGRAPHY
iCPC
Designed for research /pilot scale
purification Loading Capacity:
up to 50 g Nominal flow rate:
200 mL /min
Capacity (purified kg/Month):
up to 50 kgDimensions (W x H x D):
3’3” x 4’3” x 3’5” Weight: 1,036 lbs
CORE ADVANTAGESNO MORE SILICA GEL The iCPC only uses liquid solvents for the separation of the major and minor cannabinoids.
UNPARALLELED ADAPTABILITY The CPC infrastructure can be adapted for a new purification project within hours.
SUSTAINABLE Both liquid mobile and stationary phases can be recycled and recirculated into the system.
FEWER STEPS The highly resilient technique does not require dewaxing or winterization prior to processing.
>99% PURITY The iCPC platform is being used to isolate the major and minor cannabinoids to >99% purity, remediate pesticides, or remove THC.
pCPC RotaChrom’s pCPC (plant CPC) is a completely integrated industrial scale CPC purification platform with optimized solvent system preparation and recycling. This platform is capable of performing continuous batch production, processing 1 to 2 kg/hour of input material.
pCPC
Tel.: +36 70 885 6922 E-mail: [email protected] www.rotachrom.com
iCPC
PESTICIDE REMEDIATIONRotaChrom’s iCPC platform is capable of remediating the most commonly used pesticides from cannabis/hemp extracts and reduce their concentration below regulatory limits.
INCLUDING but not limited to:
Bifenazate<0.1 ppm
Spiromesifen<0.1 ppmSpinosad
<0.1 ppm
Myclobutanil<0.1 ppm
Carbaryl<0.5 ppm
rCPC