+ All Categories
Home > Documents > Industrial Gigabit Media Converters & Gigabit Ethernet...

Industrial Gigabit Media Converters & Gigabit Ethernet...

Date post: 17-Aug-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
32
N-Tron ® 1000 Series Industrial Gigabit Media Converters & Gigabit Ethernet Switches Hardware Guide | March 2015
Transcript
Page 1: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

N-Tron® 1000 Series

Industrial Gigabit Media Converters& Gigabit Ethernet Switches

Hardware Guide | March 2015

Page 2: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

COPYRIGHTCopyright, © 2015 Red Lion Controls, Inc.

20 Willow Springs Circle

York, PA 17406

All rights reserved. Red Lion, the Red Lion logo and N-Tron are registered trademarks of Red Lion Controls,Inc. All other company and product names are trademarks of their respective owners.

The information contained in this document is subject to change without notice. Red Lion makes no warrantyof any kind with regard to this material, including, but not limited to, the implied warranties of merchantabilityor fitness for a particular purpose. In no event shall Red Lion be liable for any incidental, special, indirect orconsequential damages whatsoever included but not limited to lost profits arising out of errors or omissionsin this manual or the information contained herein.

CONTACT INFORMATION :

AMERICASYork, PA: +1 (717) 767-6511Mobile, AL: +1 (251) 342-2164Ballston Lake, NY: +1 (518) 877-5173Hours: 8am-6pm Eastern Standard Time(UTC/GMT -5 hours)

ASIA-PACIFICShanghai, P.R. China: +86 21-6113-3688 x767Hours: 10am-6pm China Standard Time(UTC/GMT +8 hours)

EUROPEThe Netherlands: +31 33-4723-225Hours: 9am-6pm Central European Time(UTC/GMT +1 hour)

Website: www.redlion.net

Email: [email protected]

Page 3: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Table of Contents Revised 2015-03-24

Table of Contents

Preface

Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiiCompliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference . . . . . . iiiIndustry Canada . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii

Environmental Impact Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivToxic Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivTrademark Acknowledgments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivRelease Notes and Document Updates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

Publication History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivRelated Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivDocument Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv

Additional Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ivWarnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v

General Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vElectrical Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vEnvironmental Safety Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiHazardous Location Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viiLaser Safety Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii

Introduction and Specifications

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1Product Ordering Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2Model 1002MC Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3Model 1002MC Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4

Model 1003GX2 - Key Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5Model 1003GX2 Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6

N-Tron 1000 Series Hardware Guide i

Page 4: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Table of Contents Revised 2015-03-24

Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6Model 1005TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7Model 1005TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-8

Model 1008TX - Key Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9Model 1008TX Regulatory Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9EMI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-9EMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10

Installation

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11Installing/Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11

DIN-Rail Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13

Power Connection (Top View) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13 Ground Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13

N-Tron Series Switch Grounding Techniques for 1000 Series . . . . . . . . . . . . . . . . . . . . . . . . 2-13 Cable Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15

Operation and Maintenance

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17

Model 1002MC, 1003GX2, 1005TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-17 Model 1008TX Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-18

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19Verify/Troubleshoot Cable Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-19

Red Lion Controls N-Tron 1000 Series Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-20

ii N-Tron 1000 Series Hardware Guide

Page 5: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

Preface

DisclaimerPortions of this document are intended solely as an outline of methodologies to be followed during themaintenance and operation of N-Tron 1000 Series equipment. It is not intended as a step-by-step guide or acomplete set of all procedures necessary and sufficient to complete all operations.

While every effort has been made to ensure that this document is complete and accurate at the time of release, the information that it contains is subject to change. Red Lion Controls is not responsible for any additions to oralterations of the original document. Industrial networks vary widely in their configurations, topologies, and traffic conditions. This document is intended as a general guide only. It has not been tested for all possible applications, and it may not be complete or accurate for some situations.

Users of this document are urged to heed warnings and cautions summarized at the front of the document, such as electrical hazard warnings.

Compliance InformationIt is recommended that the owner of this equipment determine and ensure conformance with any specific and applicable local regulations.

Part 15 of the Federal Communications Commission (FCC) - A Rules: Interference Every effort has been made to ensure that this equipment is designed to comply with the limits for a Class A digital device, as described in the FCC Rules.

This product complies with Part 15 of the FCC-A Rules.

Operation is subject to the following conditions:

1. This device may not cause harmful Interference2. This device must accept any interference received, including interference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own expense.

Industry CanadaThis Class A digital apparatus meets all requirements of the Canadian Interference Causing EquipmentRegulations. Operation is subject to the following two conditions; (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y comprisl'interférence qui peut causer l'opération peu désirée.

N-Tron 1000 Series Hardware Guide iii

Page 6: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

Environmental Impact StatementRed Lion equipment contains no hazardous materials as defined by the United States Environmental Protection Agency (USEPA). Red Lion recommends that all failed product be returned to Red Lion for failure analysis and proper disposal.

Toxic EmissionsRed Lion equipment releases no toxic emissions.

Trademark AcknowledgmentsEthernet is a registered trademark of Xerox Corporation.

EtherNet/IPTM and CIPTM are registered trademarks of ODVA.

Release Notes and Document UpdatesThe hard copy and electronic media versions of this document are revised only at major releases and therefore, may not always contain the latest product information. As needed, Documentation Notes and or Product Bulletins will be provided between major releases to describe any new information or document changes.

The latest online version of this document and all product updates can be accessed through the Red Lion web site at http://www.redlion.net

Publication HistoryThe following information lists the release history of this document.

Related DocumentsVisit the Technical Resources page on the Red Lion website at the following link to view available documents related to this product.

http://www.redlion.net/documentation/red-lion-documentation

Document CommentsRed Lion appreciates all comments that will help us to improve our documentation quality. The user can submit comments through the Red Lion Customer Service. Simply email us at [email protected].

Additional Product InformationAdditional product information can be obtained by contacting the local sales representative or Red Lion through the contact numbers and/or e-mail addresses listed on the inside of the front cover.

ISSUE/REVISION RELEASE DATE CONTENT DESCRIPTION

Revised 2014-01-23 January 2014 Document Updates

Revised 2015-03-17 March 2015 Added 1008TX Model, Format Changes

Revised 2015-03-24 March 2015 Format Changes to Cover, Page Header and Tables

iv N-Tron 1000 Series Hardware Guide

Page 7: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

Warnings and CautionsWarnings apply to situations where personal injury or death may result.

Cautions apply to where reduced function or damage to equipment may result.

General Safety Cautions and Warnings

Electrical Safety Warnings

CAUTION: If the N-Tron series equipment is used in the manner not specified by Red Lion, the protection provided by the equipment may be impaired.ATTENTION: Si l' N-Tron série équipement est utilisé d'une manière non spécifiée par Red Lion, la protection fournie par l'équipement peut être compromise.

CAUTION: Do not perform any services on the unit unless qualified to do so. Do not substitute unauthorized parts or make unauthorized modifications to the unit.ATTENTION: Ne pas effectuer de services sur l'appareil s'il n'est pas qualifié pour le faire. Ne pas substituer pièces non autorisées ou de modifications non autorisées de l'appareil.

CAUTION: Do not operate the equipment in a manner not specified by this manual.ATTENTION: Ne pas faire fonctionner l'équipement d'une manière non spécifiée par ce manuel.

WARNING: Install only in accordance with Local and National Codes of authorities havingjurisdiction.ALERTE: Installer uniquement, conformément aux codes locaux et nationaux des autorités ayant compétence.

WARNING: Do not work on equipment or cables during periods of lightning activity.ALERTE: Ne pas travailler sur le matériel ou les câbles pendant les périodes d'activité de la foudre.

N-Tron 1000 Series Hardware Guide v

Page 8: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

WARNING: Properly ground the unit before connecting anything else to the unit. Units notproperly grounded may result in a safety risk and could be hazardous and may void the warranty. See the grounding technique section of this Hardware Guide for proper ways to ground the unit.ALERTE: Correctement à la terre de l'unité avant tout raccordement à l'unité. Unités pascorrectement mise à la terre peut entraîner un risque de sécurité et pourraient être dangereux et peut annuler la garantie. Voir la section technique de mise à la terre de ce mode d'emploi des moyens appropriés à la masse de l'appareil.

WARNING: This equipment must be used with a Listed UL Industrial Power Supply.ALERTE: Cet équipement doit être utilisé avec une alimentation UL Listed industrielle.

WARNING: This equipment (1005TX and 1008TX) must be used with a Listed UL Class 2 Power Supply.ALERTE: Cet équipement (1005TX and 1008TX) doit être utilisé avec une alimentation UL Listed Classe 2.

WARNING: A Recognized or Listed fuse, rated maximum 3A, minimum 30VDC, must be installed on the line side of the device.ALERTE: Un fusible reconnu ou classé, classé 3A maximale, 30VDC minimum, doit être installé sur le côté de la ligne de l'appareil.

WARNING: Use 110°C or higher rated copper wire, (0.22Nm) 2 lb/in tightening torque for field installed conductors.ALERTE: Utilisez 110°C ou nominale supérieure fil de cuivre, (0,22 Nm) 2 lb/pouce couple deserrage pour le champ installé conducteurs.

WARNING: Do not operate the unit with the end plates removed, as this could create a shock or fire hazard.ALERTE : Ne pas faire fonctionner l'unité avec les plaques d'extrémité retiré, ce qui pourrait créer une décharge électrique ou un incendie.

CAUTION: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage polarity can cause permanent damage to the unit and voids the warranty.ATTENTION: Respecter la polarité correcte de tension DC lors de l'installation des câblesd'alimentation d'entrée. Inversion de polarité de tension peut causer des dommages permanents à l'appareil et annule la garantie.

vi N-Tron 1000 Series Hardware Guide

Page 9: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

Environmental Safety Cautions and Warnings

Hazardous Location Warning

CAUTION: This equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D ornon-hazardous locations only.ATTENTION: Cet équipement est adapté pour une utilisation dans la classe I, Division 2, Groupes A, B, C et D ou non dangereux endroits seulement.

WARNING: Explosion Hazard – Substitution of components may impair suitability for Class I,Division 2.ALERTE - Risque d'explosion - Remplacement d'un composant peut empêcher la conformité de Classe I, Division 2.

WARNING: Do not operate the equipment in the presence of flammable gases or fumes. Operat-ing electrical equipment in such an environment constitutes a definite safety hazard.ALERTE : Ne pas utiliser le matériel en présence de gaz ou de vapeurs inflammables. L'utilisation de matériel électrique dans un tel environnement constitue un danger certain.

WARNING – Explosion Hazard – Do not connect or disconnect any connections while circuit is live unless area is known to be non-hazardous.ALERTE - Risque d'explosion - Ne pas brancher ou débrancher les connexions lorsque le circuit est sous tension sauf si la zone est connue pour être non dangereux.

WARNING: Disconnect the power and allow to cool 5 minutes before touching.ALERTE: Déconnectez le câble d'alimentation et laisser refroidir 5 minutes avant de la toucher.

WARNING (1005TX and 1008TX only): This equipment is open-type device and is meant to be installed in an enclosure suitable for the environment that is only accessible with the use of a tool.ALERTE (1005TX and 1008TX uniquement): Cet équipement est ouvert de type périphérique et est destiné à être installé dans un boîtier adapté à l'environnement qui n'est accessible qu'avec l'utilisation d'un outil.

N-Tron 1000 Series Hardware Guide vii

Page 10: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Preface Revised 2015-03-24

Laser Safety Warning

CAUTION (1002MC and 1003GX2 only): CLASS 1 LASER PRODUCT. Do not stare into the laser.

ATTENTION (1002MC et 1003GX2 uniquement): PRODUIT LASER CLASSE 1. Ne pas regarder dans le laser.

viii N-Tron 1000 Series Hardware Guide

Page 11: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Section 1 Introduction and Specifications

IntroductionThe N-Tron 1000 Series Unmanaged Industrial Gigabit Ethernet Switches support high speed layer 2 switching between ports. This series of switches are housed in a ruggedized aluminum enclosure, and provide Category-5 compliant 10/100/1000Base-T connections for high performance network design, and hub/repeater upgrades.

All fiber products utilize the IEEE compliant LC duplex connectors for fiber optic communications in a convenient SFP (Small Form Pluggable) modular design. All 10/100/1000Base-T ports utilize the RJ45 shielded connectors.

The 1002MC/MCE is a two port unmanaged media converter that converts 10/100/1000Base-T copper to 1000BaseSX/LX full duplex fiber.

The 1003GX2/GXE2 is a three port unmanaged switch that offers one 10/100/1000Base-T copper port and two 1000BaseT/SX/LX full duplex copper/fiber ports.

The 1005TX is a five port unmanaged switch that offers five 10/100/1000Base-T copper ports.

The 1008TX is an eight port unmanaged switch that offers eight 10/100/1000Base-T copper ports.

Key Features• Compact Space Saving Package• Full IEEE 802.3 Compliance• Unmanaged Operation• Jumbo Frame Support (1005TX and 1008TX only)• Extended Environmental Specifications• -40°C to 85°C Operating and Storage Temperature• Supports Full/Half Duplex Operation• Up to 16.0 Gb/s Maximum Throughput• MDIX Auto Sensing Cable• Auto Sensing Speed and Flow Control• Full Wire Speed Communication• Store-and-Forward Switching Technology• Redundant Power Inputs (10-30 VDC, 10-49VDC for 1008TX)• LED Link/Activity Status Indication• Hardened Metal Enclosure• Industry Standard 35mm DIN Rail Mounted Enclosure

N-Tron 1000 Series Hardware Guide 1-1

Page 12: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Product Ordering GuideThe 1000 Series Media Converter and Unmanaged Industrial Gigabit Ethernet Switch model part numbers and net-work applications are presented in Table 1.

Table 1. Ordering Guide

Where: “YY” or “ZZ” is: 10 for 10km maximum fiber segment length40 for 40km maximum fiber segment length80 for 80km maximum fiber segment length

PART NUMBER APPLICATION1002MC-SX 1000BaseSX Multimode fiber Media Converter1002MC-LX-YY 1000BaseLX Singlemode fiber Media Converter1003GX2 Three port; One 10/100/100BaseT; Two 1000BaseSX/LX Gigabit Ethernet Switch 1003GX2-B One 10/100/1000BaseT port; Two 1000BaseSX/LX ports with mix-and-match SFP Mini-GBIC

fiber transceivers. Note: Unit must be populated with two SFP transceivers upon shipment 1003GX2-SX One 10/100/1000BaseT port; Two (2) 1000BaseSX SFP Mini-GBIC fiber transceivers 1003GX2-LX-10 One 10/100/1000BaseT port; Two (2) 1000BaseLX-10 SFP transceivers 1003GX2-LX-40 One 10/100/1000BaseT port; Two (2) 1000BaseLX-40 SFP transceivers 1003GX2-LX-80 One 10/100/1000BaseT port; Two (2) 1000BaseLX-80 SFP transceivers1005TX Five port 10/100/1000BaseT Gigabit Ethernet switch1008TX Eight port 10/100/1000BaseT Gigabit Ethernet switchNTSFP-SX One 1000BaseSX Multimode SFP Gigabit Transceiver with LC Style Connector for up to

550m fiber segment length (two required per unit)NTSFP-LX-ZZ One 1000BaseLX Singlemode SFP Gigabit Transceiver with LC Style Connector for up to ZZ

fiber segment length (two required per unit)NTPS-24-1.3 DIN-Rail Power Supply [email protected] amp; Used with all models1000-PM Panel Mount kit; Used with all models

N-Tron 1000 Series Hardware Guide 1-2

Page 13: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1002MC Key Specifications Table 2. 1002MC - Key Specifications

Table 3. Gigabit Fiber Transceiver SFP Characteristics

PHYSICAL ELECTRICALHeight 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC

(Steady State)Depth w/ typical SFP installed 3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @

24VDCWeight 0.70 lbs (0.32 kg) Input Ripple Less than 100 mVDIN Rail 35 mm Input Wire Size 12-24 AWG

ENVIRONMENTAL NETWORK MEDIAOperating Temperature -40°C to 85°C 10BaseT Cat-3Storage Temperature -40°C to 85°C 100BaseT Cat-5Operating Humidity 10% to 90%

(Non Condensing)1000BaseT Cat-5e

Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125μm1000BaseLX Singlemode 7-10/125μm

CONNECTOR RECOMMENDED MINIMUM WIRING CLEARANCE10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)1000Base-X SFP One (1) SFP LC Duplex

Gigabit Fiber PortFront 4 " (10.16 cm)

NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80

FIBER LENGTH550m with 50/125μm275m @ 62.5/125μm

10km 40km 80km

TX POWER MIN -9.5dBm -9.5dBm -2dBm 0dBm

RX SENSITIVITY MAX -17dBm -20dBm -22dBm -24dBm

WAVELENGTH 850nm 1310nm 1310nm 1550nm

ASSUMED FIBER LOSS 3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km

LASER TYPE VCSEL FP DFB DFB

N-Tron 1000 Series Hardware Guide 1-3

Page 14: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1002MC Regulatory Approvals

SafetyFor use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.

• UL 508, Industrial Control Equipment.• ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous

(Classified) Locations Groups A, B, C, D. T4A.• cUL C22.2 No. 14-M05• cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.

EMI• EN61000-6-4, EN55011 - Class A• FCC Title 47, Part 15, Subpart B - Class A• ICES-003 – Class A

EMS• EN61000-6-2• EN61000-4-2 (ESD)• EN61000-4-3 (RS)• EN61000-4-4 (EFT)• EN61000-4-5 (Surge)• EN61000-4-6 (Conducted Disturbances)

Warranty3 years from the date of purchase.

N-Tron 1000 Series Hardware Guide 1-4

Page 15: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1003GX2 - Key SpecificationsTable 4. 1003GX2 Key Specifications

Table 5. Gigabit Fiber Transceiver (SFP) Characteristics

PHYSICAL ELECTRICALHeight 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)Width 1.0” (2.54 cm) Input Current 200mA max. @ 24VDC

(Steady State)Depth w/ typicalSFP installed

3.61” (9.165 cm) Inrush Current 13 Amp/0.8 ms max. @24VDC

Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mVDIN Rail 35 mm Input Wire Size 12-24 AWG

ENVIRONMENTAL NETWORK MEDIAOperating Temperature -40°C to 85°C 10BaseT Cat-3Storage Temperature -40°C to 85°C 100BaseT Cat-5Operating Humidity 10% to 90%

(Non Condensing)1000BaseT Cat-5e

Operating Altitude 0 to 10,000 ft. 1000BaseSX Multimode 50-62.5/125μm1000BaseLX Singlemode 7-10/125μm

CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE10/100/1000BaseTX One (1) RJ45 TX Copper Port Top 1 " (2.54 cm)1000Base-X SFP Up to two (2) SFP LC Duplex

Gigabit Fiber PortsFront 4 " (10.16 cm)

NTSFP-SX NTSFP-LX-10 NTSFP-LX-40 NTSFP-LX-80

FIBER LENGTH550m with 50/125μm275m @ 62.5/125μm

10km 40km 80km

TX POWER MIN -9.5dBm -9.5dBm -2dBm 0dBm

RX SENSITIVITY MAX -17dBm -20dBm -22dBm -24dBm

WAVELENGTH 850nm 1310nm 1310nm 1550nm

ASSUMED FIBER LOSS 3.5 to 3.75 dB/km 0.45 dB/km 0.35 dB/km 0.25 dB/km

LASER TYPE VCSEL FP DFB DFB

N-Tron 1000 Series Hardware Guide 1-5

Page 16: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1003GX2 Regulatory Approvals

SafetyFor use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.

• UL 508, Industrial Control Equipment.• ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous

(Classified) Locations Groups A, B, C, D. T4A.• cUL C22.2 No. 14-M05• cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.

EMI• EN61000-6-4, EN55011 - Class A• FCC Title 47, Part 15, Subpart B - Class A• ICES-003 – Class A

EMS• EN61000-6-2• EN61000-4-2 (ESD)• EN61000-4-3 (RS)• EN61000-4-4 (EFT)• EN61000-4-5 (Surge)• EN61000-4-6 (Conducted Disturbances)

Warranty3 years from the date of purchase.

N-Tron 1000 Series Hardware Guide 1-6

Page 17: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1005TX - Key SpecificationsTable 6. 1005TX Key Specifications

Model 1005TX Regulatory Approvals

SafetyFor use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.

• UL 508, Industrial Control Equipment• ANSI/ISA-12.12.01-2007 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous

(Classified) Locations Groups A, B, C, D. T4• cUL C22.2 No. 14-M05• cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.

EMI• EN61000-6-4, EN55011 - Class A• FCC Title 47, Part 15, Subpart B - Class A• ICES-003 – Class A

PHYSICAL ELECTRICALHeight 4.0” (10.16 cm) Input Voltage 10-30 VDC (Regulated)Width 1.0” (2.54 cm) Input Current 230mA max. @ 24VDC

(Steady State)Depth w/ typicalSFP installed

3.61” (9.165 cm) Inrush Current 13 Amp/0.61 ms max. @24VDC

Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mVDIN Rail 35 mm Input Wire Size 12-24 AWG

ENVIRONMENTAL NETWORK MEDIAOperating Temperature -40°C to 85°C 10BaseT Cat-3Storage Temperature -40°C to 85°C 100BaseT Cat-5Operating Humidity 10% to 90%

(Non Condensing)1000BaseT Cat-5e

Operating Altitude 0 to 10,000 ft.

CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE10/100/1000BaseTX Five (5) RJ45 TX Copper

PortsTop 1 " (2.54 cm)

Front 2 " (5.08 cm)

N-Tron 1000 Series Hardware Guide 1-7

Page 18: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

EMS• EN61000-6-2• EN61000-4-2 (ESD)• EN61000-4-3 (RS)• EN61000-4-4 (EFT)• EN61000-4-5 (Surge)• EN61000-4-6 (Conducted Disturbances)

Warranty3 years from the date of purchase.

N-Tron 1000 Series Hardware Guide 1-8

Page 19: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

Model 1008TX - Key SpecificationsTable 7. 1008TX Key Specifications

Model 1008TX Regulatory Approvals

SafetyFor use in Class I, Division 2, Groups A, B, C and D Hazardous Locations.

• UL 508, Industrial Control Equipment.• ANSI/ISA-12.12.01-2013 for use in Class I and II, Division 2 and Class III Divisions 1 and 2 Hazardous (Classi-

fied) Locations Groups A, B, C, D. T4.• cUL C22.2 No. 14-M05• cUL C22.2 No. 213-M1987 for use in Class I, Division 2 Hazardous Locations.

EMI• FCC Title 47, Part 15, Subpart B - Class A• Industry Canada ICES-003 – Class A• EN 55011 - Class A• EN 61000-6-4• EN 61000-3-2/3

PHYSICAL ELECTRICALHeight 4.63” (11.76 cm) Input Voltage 10-49 VDC (Regulated)Width 1.55” (3.94 cm) Input Current 290mA max. @ 24VDC

(Steady State)Depth w/ typicalSFP installed

4.08” (10.37 cm) Inrush Current 20 Amp/0.06 ms max. @24VDC

Weight 0.7 lbs (0.32 kg) Input Ripple Less than 100 mVDIN Rail 35 mm Input Wire Size 12-24 AWG

ENVIRONMENTAL NETWORK MEDIAOperating Temperature -40°C to 85°C 10BaseT Cat-3Storage Temperature -40°C to 85°C 100BaseT Cat-5Operating Humidity 10% to 90%(Non Condens-

ing)1000BaseT Cat-5e

Operating Altitude 0 to 10,000 ft.

CONNECTORS RECOMMENDED MINIMUM WIRING CLEARANCE10/100/1000BaseTX Eight (8) RJ45 TX Copper

PortsTop 1 " (2.54 cm)

Front 2 " (5.08 cm)

N-Tron 1000 Series Hardware Guide 1-9

Page 20: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Introduction and Specifications Revised 2015-03-24

EMS• EN 61000-6-2• EN 61000-4-2/3/4/5/6/8/11

Warranty3 years from the date of purchase.

N-Tron 1000 Series Hardware Guide 1-10

Page 21: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

Section 2 Installation

Introduction

This sections contains the information and procedures necessary to unpack, inspect, install and connect theN-Tron 1000 Series equipment.

Unpacking

Remove all the equipment from the packaging, and store the packaging in a safe place.

Inspection

Please ensure the shipping package contains the following items in undamaged condition:

1. N-Tron 1000 Series Media Converter or Ethernet Switch.2. Product CD.

If the package contents are damaged:

1. Contact your carrier.2. File any damage claims with the carrier.

Installing/Mounting

Read the following warning before beginning the installation:

Lire l'avertissement suivant avant de commencer l'installation:

WARNING: Never install or work on electrical equipment or cabling during peri-ods of lightning activity. Never connect or disconnect power when hazardousgases are present.ALERTE: Ne jamais installer ou de travailler sur un équipement électrique ou decâblage pendant les périodes d'activité de la foudre. Ne jamais brancher oudébrancher l'alimentation en gaz dangereux sont présents

N-Tron 1000 Series Hardware Guide 2-11

Page 22: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

DIN-Rail Mounting a. Install the unit in a standard DIN rail. Recess the unit to allow at least 2” of horizontal clearance for CAT5e

cable bend radius or 5” of horizontal clearance for Fiber Optic cable bend radius.

URMK 1000-PM

Most Red Lion N-Tron™ products are designed to be mounted on industry standard 35mm DIN rail. However, DIN rail mount-ing may not be suitable for all applications. Our Universal Rack Mount Kit (P/N: URMK) can be used to mount the 1000 Series enclosures to standard 19" racks, and our Panel Mount Assembly (P/N: 1000-PM) can be used to mount the 1000 Series enclosures to a panel or any other flat surface.

b. To install the unit to 35mm industrial DIN rail, place the top edge of the included mounting bracket on the back of the unit against the DIN rail at a 15° angle as shown. Rotate the bottom of the unit to the back (away from you) until it snaps into place.

c. To remove the unit from the 35mm industrial DIN rail, pull forward on the unit until it disen-gages from the bottom of the DIN rail. Rotate the bottom of the unit towards you and up at an approximate 15° upward angle to completely remove the unit.

N-Tron 1000 Series Hardware Guide 2-12

Page 23: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

Connections

Power Connection (Top View)

1. Unscrew & Remove the DC Voltage Input Plug from the top header.2. Install the DC Power Cables into the Plug (observing polarity on unit).3. Plug the Voltage Input Plug back into the top header.4. Tightening torque for the terminal block power plug is 0.5 Nm/0.368 Pound Foot.5. Verify the Power LED stays ON (GREEN).

Note: Either V1 or V2 can be connected to power for minimal operation. For redundant power opera-tion, V1 and V2 plugs must be connected to separate DC Voltage sources. Use wire sizes of 12-24 gauge. Limit he power cord length to less than 10 meters in order to ensure optimum performance.

Recommend using 24V DC Power Supplies, similar to:

• 100-240VAC:N-Tron NTPS-24-1.3, DC 24V/1.3A

Ground Connection

N-Tron Series Switch Grounding Techniques for 1000 SeriesThe grounding philosophy of any control system is an integral part of the design. N-Tron series switches are designed to be grounded, but the user has been given the flexibility to float the switch when required. The best noise immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via a drain wire. Some N-Tron series switches have metal din-rail brackets that can ground the switch if the din-rail is grounded. In some cases, N-Tron series switches with metal brackets can be supplied with optional plastic brackets if isolation is required.

N-Tron 1000 Series Hardware Guide 2-13

Page 24: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

Note: The V-legs of the power input connector are connected to the chassis internally on the 1002MC, 1003GX2 and 1005TX. Before applying power to the grounded switch, you must use a volt meter to verify there is no voltage difference between the power supply’s negative output ter-minal and the switch chassis grounding point.

If the use of shielded cables is required, it is generally recommended to only connect the shield at one end to pre-vent ground loops and interfere with low level signals (i.e. thermocouples, RTD, etc.). Cat5e cables manufactured to EIA-568A or 568B specifications are required for use with N-Tron series switches.

In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals.

Users may run a drain wire & lug from the screw provided on the back face of the enclosure. In the event the provided grounding screw has been lost, care should be taken to limit the penetration of the outer skin by less than 1/4". Failure to do so may cause irreversible damage to the internal components of the switch.

Note: Ensure the power supply is grounded properly before applying power to the grounded switch. This can be verified by using a voltmeter to determine that there is no voltage difference between the power supply’s negative output terminal and the chassis grounding point of the switch.

Drain wire with lug connecting switch chassisto known god grounding posts.

N-Tron 1000 Series Hardware Guide 2-14

Page 25: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

Cable Connection

Cable connections are dependent on the network configuration and N-Tron 1000 Series model in use.

1. For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector.2. For 100/1000Base-T ports, plug a Category 5e (or greater) twisted pair cable into the RJ45 connector. Con-

nect the other end to the far end station.3. Verify that the LNK/ACT LEDs are ON once the connection has been completed.4. To connect any other port to another Switch or Repeater, use a standard Cat5e straight through or crossover

cable.

CAUTION: Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and will create a broadcast storm which will crash the network!ATTENTION: Création d'un port de connexion du port sur le même commutateur(c.-à-boucle) est une opération illégale et va créer une tempête de diffusion qui va planter le réseau!

N-Tron 1000 Series Hardware Guide 2-15

Page 26: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Installation Revised 2015-03-24

N-Tron 1000 Series Hardware Guide 2-16

Page 27: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

Section 3 Operation and Maintenance

Introduction

The N-Tron 1000 Series Gigabit Media Converter & Industrial Gigabit Ethernet Switch devices provide operating status information through the LED indicators located on the front panel.

Controls and Indicators

Model 1002MC, 1003GX2, 1005TX Indicators

Table 8. Model 1002MC, 1003GX2, 1005TX Indicators (from top to bottom)

INDICATOR DESCRIPTION

Green LED lights when power is connected

LNK/ACT LED indicating link/activity

SPD1000 LED indicating 1000 Link data speed

N-Tron 1000 Series Hardware Guide 3-17

Page 28: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

Table 9 describes the indicator states and the operating modes:

Table 9. Model 1002MC, 1003GX2, 1005TX Indicator States

Model 1008TX Indicators

Table 10. Model 1008TX Indicators (from top to bottom)

INDICATOR STATE DESCRIPTION

ON Power is appliedOFF Power is offON Link established, no activity on cable

LNK/ACT BLINKING Link established, activity on cableOFF No link activity on cable

SPD1000 ON Link is operating at 1000MbpsOFF Link is operating at 10/100Mbps

INDICATOR DESCRIPTION

Green LED lights when power is connected

ACT LED indicating activity

1000 LED indicating 1000 Link data speed

3-18 N-Tron 1000 Series Hardware Guide

Page 29: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

Table 11 describes the indicator states and the operating modes:

Table 11. Model 1008TX Indicator States

Maintenance

Maintenance is limited to verifying the cable interface and unit cleaning.

Verify/Troubleshoot Cable Interface

1. Make sure the (Power LED) is ON.2. Make sure you are supplying sufficient current for the chosen switch version.

Note: The inrush current will exceed the steady state current by ~ 2X.

3. Verify that Link LEDs are ON for both ports.4. Verify cabling used between stations.5. Verify that cabling is Category 3 or greater for 10Mbps Operation.

CleaningClean hardware only with a damp cloth.

INDICATOR STATE DESCRIPTION

ON Power is appliedOFF Power is off

ACT ON/BLINKING Link established, activity on cableOFF No link activity on cable

1000 ON Link is operating at 1000MbpsOFF Link is operating at 10/100Mbps

N-Tron 1000 Series Hardware Guide 3-19

Page 30: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

Red Lion Controls N-Tron 1000 Series Limited Warranty

Red Lion warrants to the end user that this hardware product will be free from defects in workmanship and materi-als, under normal use and service, for the applicable warranty period from the date of purchase from Red Lion or its authorized reseller. If a product does not operate as warranted during the applicable warranty period, Red Lion shall, at its option and expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item, or refund to customer the purchase price paid for the defective product. All prod-ucts that are replaced will become the property of Red Lion. Replacement products may be new or reconditioned. Any replaced or repaired product or part has a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer. Red Lion shall not be responsible for any custom software or firmware, configuration information, or memory data of customer contained in, stored on, or integrated with any products returned to Red Lion pursuant to any warranty.

OBTAINING WARRANTY SERVICE: Customer must contact Red Lion within the applicable warranty period to obtain warranty service authorization. Dated proof of purchase from Red Lion or its authorized reseller may be required. Products returned to Red Lion must be pre-authorized by Red Lion with a Return Material Authorization (RMA) number marked on the outside of the package, and sent prepaid and packaged appropriately for safe ship-ment. Responsibility for loss or damage does not transfer to Red Lion until the returned item is received by Red Lion. The repaired or replaced item will be shipped to the customer, at Red Lion's expense, not later than thirty (30) days after Red Lion receives the product. Red Lion shall not be responsible for any software, firmware, information, or memory date of customer contained in, stored on, or integrated with any products returned to Red Lion for repair, whether under warranty or not.

ADVANCE REPLACEMENT OPTION: Upon registration, this product qualifies for advance replacement. A replacement product will be shipped within three (3) days after verification by Red Lion that the product is consid-ered defective. The shipment of advance replacement products is subject to local legal requirements and may not be available in all locations. When an advance replacement is provided and customer fails to return the original product to Red Lion within fifteen (15) days after shipment of the replacement, Red Lion will charge customer for the replacement product, at list price.

WARRANTIES EXCLUSIVE: IF A RED LION PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, CUS-TOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT RED LION’S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANT-ABILITY, FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. RED LION NEI-THER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. RED LION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUS-TOMER'S OR ANY THIRD PERSON'S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAU-THORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.

LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, RED LION ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEG-LIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION,

3-20 N-Tron 1000 Series Hardware Guide

Page 31: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF N-TRON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REM-EDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.

DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for personal injury, so the above limitations and exclusions may be limited in their application to you. When the implied warranties are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty. This warranty gives you specific legal rights which may vary depending on local law.

GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Delaware, U.S.A.

N-Tron 1000 Series Hardware Guide 3-21

Page 32: Industrial Gigabit Media Converters & Gigabit Ethernet ...store.express-inc.com/pdf/1000Series_UserManual.pdf · device, as described in the FCC Rules. This product complies with

Operation and Maintenance Revised 2015-03-24

3-22 N-Tron 1000 Series Hardware Guide


Recommended