The Quick4 High Capacity Chamber can be installed in a 36-inch widetrench. The MultiPort End Cap has eight molded-in high and low inletsto allow piping to enter or exit from multiple directions.
Quick4® High Capacity Chamber
Size (W x L x H)....................34" x 53" x 16" (86 cm x 135 cm x 41 cm)
Effective Length.................................................................48" (122 cm)
IINNFFIILLTTRRAATTOORR®® QQUUIICCKK44®® CCHHAAMMBBEERR SSYYSSTTEEMMSS
Size (W x L x H)......................34" x 19" x 16" (85 cm x 48 cm x 41 cm)
Additional Length per Trench...........................................2.4 ft (71.1 cm)
Invert Height ....................................................................11.5" (29 cm)
Quick4® Equalizer® 24 and EQ24 HD Chamber
Size (W x L x H).......................16" x 53" x 11" (41 cm x 135 cm x 28 cm)
Effective Length....................................................................48" (122m)
Size (W x L x H).........................16" x 14" x 12" (41 cm x 36 cm x 31 cm)
Additional Length per Trench............................................1.88 ft (57 cm)
Invert Height .........................................................................6" (15 cm)
The Quick4 Equalizer 36 Chamber can be installed in a 24-inch widetrench. The MultiPort End Cap has six molded-in high and low inlets toallow piping to enter or exit from multiple directions.
Quick4® Equalizer® 36 Chamber
Size (W x L x H).......................22" x 53" x 12" (56 cm x 135 cm x 31 cm)
Effective Length..................................................................48" (122 cm)
Size (W x L x H).........................22" x 18" x 12" (56 cm x 46 cm x 31 cm)
Additional Length per Trench.............................................2.1 ft (64 cm)
Invert Height .........................................................................6" (15 cm)
4
Benefits Include:
Ease of Installation• Can be delivered to the site in a pickup truck and hand-carried into position • For most jobs, two people can install a system in half the time it takes for a comparable stone and pipe leachfield• Ideal for curved or straight systems, the Contour Swivel ConnectionTM allows the chamber to swivel 10-15 degrees, right or left
Cost Savings• No stone or geotextile is typically required, which eliminates the need for heavy trucks used to transport stone• Because installations are faster with chambers, you save on heavy equipment operation and labor
Less Site Disruption• Chambers typically occupy a smaller total area than stone and pipe leachfields so there is less damage to landscaping• Elimination of stone means cleanup at the job site is much easier
The Quick4 Equalizer 24 and Equalizer 24 Heavy Duty (HD) Chambercan be installed in a 18-inch or 24-inch wide trench. The MultiPort EndCap has six molded-in high and low inlets to allow piping to enter or exitfrom multiple directions.
All measurements are nominal.
The Quick4 Standard Chamber can be installed in a 36-inch widetrench. The MultiPort End Cap has eight molded-in high and low inletsto allow piping to enter or exit from multiple directions.
Quick4® Standard Chamber
Size (W x L x H)....................34" x 53" x 12" (85 cm x 135 cm x 31 cm)
Effective Length.................................................................48" (122 cm)
Size (W x L x H)......................34" x 16" x 12" (85 cm x 41 cm x 31 cm)
Additional Length per Trench.............................................2.2 ft (66 cm)
Invert Height .........................................................................8" (20 cm)
The Quick4 Equalizer 36 StraightLock Chamber is specifically designedfor use in bed applications. The MultiPort End Cap has six molded-inhigh and low inlets to allow piping to enter from multiple directions.
Quick4® Equalizer® 36 StraightLockTM Chamber
Size (W x L x H)..........................22" x 53" x 12" (56 cm x 135 cm x 31 cm)
Effective Length.....................................................................48" (122 cm)
Size (W x L x H)..........................22" x 18" x 12" (56 cm x 46 cm x 31 cm)
Additional Length per Trench.................................................2.1 ft (64 cm)
Invert Height .............................................................................6" (15 cm)
The Quick4 Equalizer 24 Low Profile (LP) Chamber is designed forshallow placement applications. The MultiPort End Cap has six molded-in high and low inlets to allow piping to enter or exit from multipledirections.
Quick4® Equalizer® 24 Low Profile Chamber
Size (W x L x H)..........................16" x 53" x 8" (41 cm x 135 cm x 23 cm)
Effective Length.....................................................................48" (122 cm)
Size (W x L x H)...............................7" x 14" x 8" (18 cm x 36 cm x 23 cm)
Additional Length per Trench................................................1.88 ft (57 cm)
Invert Height ...............................................................................2" (5 cm)
5
Built to Last• Chambers are chemical-resistant and UV-stable• Powerful arch design supports axle loads of 16,000 lbs, with 12 inches of compacted cover, equivalent to an AASHTO H-10 load
rating• All products carry a limited warranty and are certified to the International Association of Plumbing and Mechanical Officials (IAPMO)
structural testing protocol • Infiltrator has a comprehensive quality control program at their company-owned, ISO 9001:2000 certified manufacturing facilities
MultiPortTM End Caps• Inlet/Outlets allow for maximum piping flexibility• Multiple ports eliminate pipe fittings • Tear-out seals provide a tight fit to pipe• Can fit on either end of the chambers