InnoClean PLUSWastewater Treatment Systems
Fully biologic SBR wastewater treatment systems according to Euronorm EN 12566-Part 3
Leading in drainage
2
InnoClean PLUS - the natural alternative
The InnoClean PLUS system is a decentralized wastewatertreatment system which naturally treats domestic wastewaterprior to release in drywells or local waters / streams.
InnoClean PLUS wastewater treatment systems treat dome-
stic wastewater on a completely natural basis using the en-
vironmentally friendly SBR process (Sequencial Batch Reactor).
The SBR Process
The SBR treatment process is based on the cleaning efficiencyof microorganisms that naturally occur in domestic wastewater.
These microorganisms exist in the activated sludge layer insidethe chamber. During the treatment phase these microorganismsare mixed with the wastewater and supplied with oxygen whichallows them to feed on the pollutants and treat the wastewateron a completely natural basis.
The KESSEL InnoClean PLUS Wastewater Treatment Process
Compared with all other treatment systems with wastewateraeration, the SBR process offers the highest treatment efficiencyin addition to providing extremely low operation costs.
TR
E
A T M E N T C Y CL
E
6 P H A S E
8 hour
wastewater
treatment
cycle
Incoming wastewater
Wastewater enters the pre-treatmentchamber where solids settle to thebottom.
Filling of treatment chamber
The pre-treated wastewater is pumpedto the treatment chamber.
Sludge transfer
Excess sludge is returned to the sludgestorage tank
Treatment / Ventilation
of wastewater
The 6 hour treatment phase begins - the wastewater is intermittently suppliedwith bursts of oxygen.
These bursts provide the microorganismswith required oxygen to begin their treatment process (denitrification).
Sedimentation phase
After the 6 hour treatment phase a 1 or 2 hoursedimentation phase begins where sludge settlesto the base and the treated wastewater clears.
Emptying of treated wastewater
The treated wastewater is then pumped out of the treatment chamber.
After 8 hours the complete cycle has ended.In the case that sufficient wastewater isavailable in the pre-treatment chamber, the entire 8 hours cycle begins again.
In the case that no or little wastewater has been collected, the InnoClean PLUSautomatically goes into energy savingsmode.
44
55
66
11
22
33
Description of operation:
3
InnoClean PLUS wastewater treatment system
�
�
�
�
�
�
�
�
�
�
�
�
�
Control unit and compressor
Wastewater inlet
KESSEL InnoClean PLUS tank
Child proof load class B (12.5 ton) cover
Treatment tower with integrated sampling
�
�
�
Pre-treatment chamber
Integrated separation wall
Activation chamber
Outlet to dry well
Additional ventilation pipes withactive charcoal filter (optional)
Installation example
Full line of system sizes
Available in size PE* 4 to PE* 50
Low maintenance costs
User friendly operation
Interactive control unit with LCD read-out anduser friendly touch pad
Child safe, 12.5 ton load class covers
InnoClean PLUS tanks are completely watertight and
fully resistant to root penetration
Low power usage
Sleep mode and vacation mode for additional power savings
20 year manufacturer’s guarantee on polyethylene
For additional safety, quality and peace of mind:
Low weight
Complete installation handled with standard constructionequipment.
Quick connection for ventilation hoses
Easy connection of air compressor – no tools required
Treatment tower is completely removable
for maintenance / inspection
Ready to go system provides simplified on-site installation
Compressor pump and aeration diffusor
easily removed for inspection and maintenance
Three different installation versions
to meet custom installation requirements
Variable upper section:
Installation advantages
* Population Equivalent (number of inhabitants in building)
inclinableheight adjustableprivate vehicle traffic proof
4
InnoClean PLUS wastewater treatment systems
InnoClean PLUSFully biological Wastewater Treatment System according to EN 12566 manufactured from polyethylene
Single body (monolythic) tank, for underground installation.Installation depth D = ..... mm. Chamber with gasketed inlet / outlet openings for con-nection of DN 150 (Ø 160 mm) PVC inlet and outlet piping according to DIN 19534 or for DN 150 (Ø 160 mm) PE-HD inlet and outlet piping according to DIN 19537.For installation in high groundwater areas, maximum groundwater level GW = 1840 mm. With integrated, pre-installed cleaning system. All ventilation hoses and clamps for con-nection of InnoClean PLUS tank to control unit / compressor are included with system.
With control unit and low maintenance compressor (230 V 50 Hz). Float switch and aircompressor connections to be made on-site.
Installation versions:
With polyethylene temporary construction debris cover (can be used as a coverin green areas if there is sufficient protection against unauthorised opening).With polymer vertically adjustable upper section, with polymer cover(600 kg load class).With polymer vertically adjustable upper section, with concrete / cast iron cover(Class B, 12.5 t).
Article descriptionIllustration
L B
h1 GWh empty
DEC
h2D
L
2382
GW = max. ground water level DEC = depth of earth coverage h empty = height of cable piping
Certification number: Z -55.3-185
Single tank system
Inle
t
�
Out
let
�
Product overview
DEC
in mm
= D
GW
in mm
D - 255D - 255D - 255D - 255
1775177517751775
L in mm
2350235034703470
D in mm
min. max.
800 - 1005800 - 1005800 - 1005800 - 1005
Total capacity
of the system
(liters)
4800480076007600
PE*
4
6
8
10
h2
in mm
1875187518751875
B
in mm
2000200020002000
h1
in mm
1775177517751775
h emptyin mm
2000200020002000
Weight
in kg
(approx.)
530530700700
97 804
97 806
97 808
97 810
97 804A
97 806A
97 808A
97 810A
97 804B
97 806B
97 808B
97 810B
Installation version
1 2 3
1
2
3
* Population Equivalent (number of inhabitants in building)
5
Siphons de sol pour parking couvert EcogussA l’intérieur des bâtiments selon la norme EN 1253InnoClean PLUS wastewater treatment systems
Product overview
DEC
in mm
= D
GW
in mm
D - 255D - 255D - 255D - 255D - 255D - 255D - 255D - 255D - 255D - 255
1775177517751775177517751775177517751775
L in mm
2350235023502350235023502350347034703470
2350235023503470347034703470235023502350
D in mm
min. max.
800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005
Total capacity
of the system
(liters)
31000310003100036600 36600 3660036600420004200042000
PE*
32
34
36
38
40
42
44
46
48
50
2350235023502350235023502350347034703470
h2
in mm
1875187518751875187518751875187518751875
B
in mm
2000200020002000200020002000200020002000
h1
in mm
1775177517751775177517751775177517751775
h emptyin mm
2000200020002000200020002000200020002000
Weight
in kg
(approx.)
2620262026202950295029502950315031503150
97 832
97 834
97 836
97 838
97 840
97 842
97 844
97 846
97 848
97 850
97 832A
97 834A
97 836A
97 838A
97 840A
97 842A
97 844A
97 846A
97 848A
97 850A
97 832B
97 834B
97 836B
97 838B
97 840B
97 842B
97 844B
97 846B
97 848B
97 850B
Installation version
Twin tank system
Three tank system
Six tank system
Tank 1Tank 2
Inlet�
Outlet
�
DEC
in mm
= D
GW
in mm
D - 255D - 255D - 255D - 255D - 255
17751775177517751775
L in mm
23503470347034703470
23502350235034703470
D in mm
min. max.
800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005
Total capacity
of the system
(liters)
9600124001240015200 15200
PE*
12
14
16
18
20
h2
in mm
18751875187518751875
B
in mm
20002000200020002000
h1
in mm
17751775177517751775
h emptyin mm
20002000200020002000
Weight
in kg
(approx.)
9701130113013001300
97 812
97 814
97 816
97 818
97 820
97 812A
97 814A
97 816A
97 818A
97 820A
97 812B
97 814B
97 816B
97 818B
97 820B
DEC
in mm
= D
GW
in mm
D - 255D - 255D - 255D - 255D - 255
17751775177517751775
L in mm
23503470347034703470
34702350235034703470
D in mm
min. max.
800 - 1005800 - 1005800 - 1005800 - 1005800 - 1005
Total capacity
of the system
(liters)
18300210002100023800 23800
PE*
22
24
26
28
30
23503470347034703470
h2
in mm
18751875187518751875
B
in mm
20002000200020002000
h1
in mm
17751775177517751775
h emptyin mm
20002000200020002000
Weight
in kg
(approx.)
12701570157017401740
97 822
97 824
97 826
97 828
97 830
97 822A
97 824A
97 826A
97 828A
97 830A
97 822B
97 824B
97 826B
97 828B
97 830B
Installation version
Tank 1 Tank 2 Tank 3
L 1
Inle
t
�
Out
let
�
L 1 L 1
Inle
t
�
Out
let
�
Out
let
�
Tank 1 Tank 2
Tank 3 Tank 4
Tank 5 Tank 6
L 1 L 1
L 1 L 1
L 1 L 1
1 2 3
1 2 3
Installation version
1 2 3
* Population Equivalent (number of inhabitants in building)
97 705-Polyethylene wall mount (includes mounting hardware)
For installation of control unit and compressor
6
Retro-fit or upgrade package
Art. #PE*Article descriptionIllustration
97 720
97 722
4/68/10
Retro-fit or upgrade package InnoClean PLUSSBR upgrade package for use in twin or multiplechamber concrete septic systems, for use withdivider walls up to 190 cm in height.
Package consists of:Air lift for loading water transfer and sludge return,quick release locks for compressor air hose, aeratorhose, valve block, air compressor, control unit and sampling chamber.
Cable and hose for connection from control unit to InnoClean PLUS - max length 15 m
97 7304-50OEM set InnoClean PLUSTreatment tower with integrated sampling forstandard equipping of twin tank pit made ofconcrete with fully biological treatment in anactivated sludge system
Package consists of:Air lift pumps for loading, water transfer pipes andsludge return with quick-release locks for the compressed air hose, aerator hose, valve block with float switch, compressor, control unit.
15 m compressed air hose.
Certification number: Z-55.32-460
Certification number: Z-55.31-454
* Population Equivalent (number of inhabitants in building)
Art. #ØArticle descriptionIllustration
97 718-Phosphate Treatment “+P”
For additional phosphate reduction for InnoClean PLUSWastewater Treatment Systems.Consists of: Dosing pump, plastic hose with screw connection and cable sleeve.
97 713-Thermostat / Hygrostat
For use in InnoClean PLUS outdoor kiosks For condensation reduction.
Accessories for InnoClean PLUS wastewater treatment systems
97 715-Warning beacon
For installation on InnoClean PLUS outdoor kiosks. For connection to InnoClean PLUS control unit.
97 712-InnoClean PLUS cable extension set
For extension of control unit and compressor cables.Max extension – 27.5 meters.
7
Siphons de sol pour parking couvert EcogussA l’intérieur des bâtiments selon la norme EN 1253Accessories for InnoClean PLUS wastewater treatment systems
Art. #ØArticle descriptionIllustration
97 716-Kiosk for control unit
and compressor housing for outdoor applications
917 406-Extension section made of polymerfor use with deeper installation depths
Extension height 510 mm; incl. gasket
smaller/larger extension sections available on request
850 114
850 116
850 117
850 118
850 119
Ø 50
Ø 75
Ø 110
Ø 125
Ø 160
Gasket for pipe conduit
860 131-Cover plate in concrete / cast iron
Class B. Traffic proof up to 12.5 ton.
860 136-Cover plate in cast iron
Class D. Traffic proof up to 40 ton.
860 117-Cover plate made of polymer
600 kg load class
860 150-Upper section made of polymer, surface water tight
For flexible adaption to the ground level, use in combinationwith covers Art. # 860 131, 860 136 and 860 117. Load class A/B or D locked, continuous height adjustmentfrom 50 mm up to 500 mm.
860 125-Upper section made of polymerfor standard manhole extension rings made of concreteand for concrete / cast iron coversCan be used in combination with standard concrete extension rings for a flexible adaption to the groundlevel. Continuous height adjustment from 50 mm up to 500 mm.
860 129-Clamping ring for upper section
for fixing the upper section during construction
860 116Ø 600Lip-sealing gasket
for connection between InnoClean PLUS tank andadjustable upper section
97 711-Cable entrance seal
Water /Odour tight seal for passage of ventilation hoseand single float switch cable. Includes additional passagefor electrical cable if required.
Leading in drainage
Right reserved for technical changes. KESSEL AG · Bahnhofstrasse 31 · 85101 Lenting · GERMANY · [email protected]
010-
342
KA
/AM
04/
13
www.kessel.com
Private homes without
public sewage connection
1 2 3 4 5
Public buildings
(e.g. leisure facility)
6 4
Private homes/mulifamily
apartments/flats
Public buildings
(e.g. gas/petrol station)
Public buildings
(e.g. hotel)
Public buildings
(e.g. hospital)
4 5
Public buildings
(e.g. industrial /
manufacturing facilities)
1 Backwater Valves 3 Lifting Stations 4 Drains / Channels 5 Separators 6 Wastewater TreatmentSystems
1 2 3 4 5
1 2 3 4 5
1 2 3 42 3 5
2 Backwater LiftingStations