26
S SPLIT TYPE M MONOBLOC TYPE Innovative Solution of Domestic Heating
Transcript
Page 1: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

SSPLIT TYPE

MMONOBLOC TYPE

Innovative Solution of Domestic Heating

Page 2: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

2 3

What’s a Heat Pump ? Absorbing the free energy from atmosphere. Heat pump system requires only 1 kW of electricity to generate 3 to 5 kW thermal energy. Primary Energy Usage Reduced Drastically!

Comfort heating

1 kWhElectricity

3 to 5 kWhof heat

2 to 4 kWhAmbient air

Direct electrical heating 278%

117%

109%

79%

Primary Energy Consumption*

Fuel boiler

Gas condensing boiler 100%

Energyheating

Outdoor unit Indoor unit

Heat

Heat

Heat

Expansionvalve

Compressor

Heat

Heat

Heat

Heat absorption

atattttatatatatttattatattttttHHHHHHHHHHHHHHeaeaHeaHeaHeaeaHeaHeaHeaHeaHeH

aattttttHHHHHHHeaaHeHe

atatattatatattttttttttttttHHHHHHHHHHHHHeaHeaHeaHeaeaHeaeaeaaaa

Emittererr

Heat

Heat

Heat

INDEX

21 Models

04 OVERVIEW

08 USAGE INTRODUCTION

14 PRODUCT TECHNOLOGY & FEATURES

20 PRODUCT LINEUP SPLIT TYPE MONOBLOC TYPE

28 SYSTEM CONFIGURATION & OPTIONAL PARTS

38 OTHERS SIMPLE INSTALLATION & MAINTENANCE INSTALLATION INFORMATION SPECIFICATIONS & DIMENSIONS MODEL SELECTION SOFTWARE

Page 3: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

4 5

Lowmaintenance

cost

Lowmainte

cos

Nopollution

NNopolluu

Nochimneysweep

OVERVIEWAdvantage

Advantage

LessCO2 Emissions

Cleanand Healthy

LowRunning Cost

EasyInstallation and Maintenance

This environmentally-friendly system substantially reduces CO2 emissions compared to conventional gas and hydro carbons combustion.

Since burners are unnecessary, NOx and other harmful substances are not generated.

*Calculations based on data provided by European Program-2001̀ for EU 27

*The values may vary depending on installation, location, and operating conditions.

pump technology.

Sophisticated arrangement of hydraulic units, allows easy piping and maintenance

All components are built into compact outdoor unit or hydraulic indoor unit.

Average annual CO2 emissions Average annual running cost

Well structured Hydraulic indoor unit.

Direct electric heating

Fuel boiler

Gas condensing boiler

0 50 100%

Direct electric heating

Fuel boiler

Gas condensing boiler

Environmentally friendly heating system

mentally friendly ating systemating system

Environmheahea

Page 4: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

7

The Energy Labelling Directive (EU)No 811/213

EHPA Quality label

Wide Comfort

OVERVIEW

The clean energy delivers “comfort” to all spaces in the home up to the living room, bedrooms, bath and swimming pool.

The Ecodesign Directive Lot1 Regulation 813/2013

The energy label aims to help consumers make direct comparisons of energy

different product labels for space heaters and combination heaters.

environmental performance of energy-related products(ErP)through design.

heaters(including heat pumps and fossil fuel boilers), combination heaters(for both space and water heating),water heaters and water storage tanks.All these products will have to meet minimum requirements for energy

s). This value is based upon the

obtained the EHPA Quality Label** by tests according to the international Standards EN14511 and EN17025. The EHPA Quality Label** is a label that shows the end-consumer a quality heat pump unit on the market.

it possible that the device can be integrated into a smart

Label, can receive signals from the power grid (and e.g. also from PV systems) about the available (unused renewable) energy (from wind, sun & water). Fujitsu

Heat Pumps series.

s < 98

s < 36

s < 34

Except low temp HP low temp HP

Heating

Swimming

temperature operation Symbol for hot water heating

Temperature map of Europe with three climate zones and the rated heat output of each

hot water heating

Optional symbol where operation is possible only in off-peak periods

temperature operation

Year when label issued Number of EU regulation

Trade markSymbol for space heating

class, from A++ (highest

Sound power level outdoors and (where relevant)

indoors

Page 5: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

Outdoor unit

Hydraulicindoorunit

DHW Tank 190 L

Heat up

19011919090900 LLLLL190190190919019019090190190909909 LLLLLLLLLL

OOutd

kkkkknnknknknkkkkkkkkkknnnnnknknknknnnaaaannnnnaaaaaaaaaTaTaaaDHW DHWDHWDHW DHWDHHW TTTTTTaTaaTaaTaaaDHW DHWDHW DHW DHW HDHW DHWDHW DHWWHWHH TTTTTTTTTTTTT

dooor unitOutdoor unit

Hydraulicindoorunit

1901901901909019019019090190909099090190900 LLLLLLLLLLLLLLLkkkkkkkkkkkkkknknknknknnknknknknknknknnnkn

HeatHeatHeatHeatHeatHeatHeaHeatateatHeat upuupupupupupupupupup

nnnnnnnnnaaaaaaaaa

eataaatateata upupuppupuuppeatatatataateataeaa upupupupupuupupup

ndondondondondodondondodondondondondondooorororororororroororunitunitunitunitunituniitnitnnitt

TaTaTaTaTaTaaTaaaDHWDHWDHWDHWDHWDHWHWDHWDHWDHWDHWDHWDHWHDHWDHWHWD W TTTTTTTTTTTTTTT

eateatatatatatata upupupuupuppHeHeHeHeHeHeHHeeHeHeHeHeHeHHeeeHeHeHeHeHeHHeeHee

iiiiiiiiiiiuuuuuuuuuu

HeHeHeHee

cccccccccccd lH d liccccccccccccHydrHydrHydrHydrHydrHydrHydrydrydrHydrydrdHydrHydrydrydrHydrdHydrraulauliauliauliauliauliauliauliauliauliauliauliuliauliiauliulHydrauliHHHHHHHHHHHHHHHHHyyyyyyyyyyyyyyndondondondondndondondondondondndondondoddodnd ororororoorrorororoorrndooryyyyyyy

iiiiiiiiiiiiiiiiyyyyyyyyy

unitunitunitunitunitunitunitunitnitunitunininitnitunittinnnunituuuuuuuuuuuuuu

Heat up

Outdoor unit

Hydraulicindoorunit

Heat up

DHW Tank 190 L

Outdoor unitOOutddoor unit

Heat upHydraulicindoorunit

190190119909900 LLLLL190190190190990190190909009099 LLLLLLLLLL

OOutdOOutd

kkknknknknknkkkkkkkkkknknnnknkknknknkkkaaananaanaaaaanaananaanaaDHWDHW DHW DHW DHWHDHWDHW TaTaTaTaTaaDHWDHW DHWDHWDHW HWHDHW DHHWHWHW H TaTTaTTaTTaTaTaTTT

dooor unitdooor unitOutdoor unit

Hydraulicindoorunit

190190190190190901901901909019090190990190901 LLLLLLLLLLLLLLL

atatataattatatatat uupupupupupuupupupuppatataatatatatatatat upupupupupuuppupup

kkkkkkkkkkkkkknknknknknknknknknknknknknkkanananaanananananana

ndondondondododondondooondondond orooroorororroorunitnititunitunitunitiuninitn

DHWDHWDHWDHWDHWDHWDHWHWDHWDHWDHWDHWDHWDHWWDHWW TaTaTaTaTaTaTaTaTTaTaTTaTaTa

HeHeHeaHeaHeaHeaHeaHeeeHeaHeaHeaHeaHeaHeHeHeHHHe

iiiniinininininiiiuuuuuuuu

ccccccccccccccd lH d liHydrHydrHydrHydrHydrHydrHydrydrydrydrHydrydrHydrydrdydrHydy rauliauliauliauliaulauliauliauliauliaulauliauliauliauliiauliuaulu ccccccccccccHydraulicHHHHHHHHHHHHHHHHHyyyyyyyyyyyyyyyndondondondondndndondndondondondondondddodd ororororoororororororondooryyyyyyyyyy

iiiiniinininininiiininniiiinyyyyyyyyyy

unitunituniunitunitunitunituniunitnitnitunitunitnnittinnnunituuuuuuuuuuuuuuu

Heat up

8

INTRODUCTION

series

series

series

All-in-one type without refrigerant piping workFor details, see page 14-15, 32-33

Split type with separate outdoor unit and hydraulic indoor unitFor details, see page 10-11, 24-27

Outdoor temperature -25°C

Outdoor temperature -20°C

Page 6: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

10 11

• Outdoor unit and hydraulic indoor unit can be installed freely, so installation is easy.

• Since hydraulic indoor unit is installed inside a house, freezing of circulated water can be prevented.

+ DHW Tankheating can be performed even at low outdoor temperature.

DHW tank (option) can be used to supply hot water by connecting it to the system.

300 Liter

Hydraulic indoor unit

All-in-one indoor unit

For cold regionsHigh Power series

Compact designComfort series

Outdoor units

page

page

page

Room heating& Domestic hot water

USAGE INTRODUCTION

Page 7: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

12 13

USAGE INTRODUCTION

Compact Design

+ DHW Tank

-ful heating can be performed even at low outdoor temperature.

DHW tank (option) can be used to supply hot water by connect-ing it to the system.

All in one model

Outdoor units

page

Weight

• Outdoor unit and hydraulic indoor unit can be installed anywhere due to compact size.

• Installation work can be performed easily only by connecting hydraulic pipes.

• DHW tank can be connected to indoor side.

300 Liter

Page 8: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

14 15

PRODUCT

&FEATURES

Page 9: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

17

Twin Rotary Compressor with Linear Control Injection Port

It realizes the high condensing temperature without overheating discharge gas temperature by Linear Control Injection process during compression. Therefore, the condensing temperature rises up higher than normal circuit. A higher hot water temperature is realized by controlling the injection amount according to the usage state.

Accurate temperature control by DC inverter technology

Time

High

Tem

pera

ture

Constant

V-PAM invertertechnology

Linear Control Injection

Evaporator

Heating cycle

Co-axial Heat Exchanger

Outdoor unit

Hydraulic unit

Linear Control Injection

Normalrefrigerantcircuit

Optimized circuit =higher water temperature

PRODUCT TECHNOLOGY

Product technology for Outdoor Unit

• Corrosion protected

• Anti-freeze-protection is unnecessary

High Durability Co-axial Heat Exchanger

Warm refrigerant flow

Heated water

Optimum Co-axialHeat Exchanger

Stainless steel buffer tank

Linear Control Injection Port

Twin Rotary Compressor

Automatic modeComfort/Reduce mode switching automatically according to time program

Reduce modeConstant reduce temperature

Comfort modeConstant comfort temperature

Protection modeStand-by mode with anti-frost protection

Class A Pump

Esay Control Hydraulic Indoor Unit Controler4 Heating mode

ClassA

Product technology for Hydraulic Indoor Unit

Page 10: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

18

Massage

MaintenanceError

Energy Saving

Safety Function

Comfort Control Programmable timer

Anti-legionella function

Automatic heating curve operation

2 Zone Individual Control*

Emergency operation

Anti-freeze function

Auto-changeover

Quick recovery from defrost operation

Backup heater operation

Error/Maintenance alarm

• The setting of timer operation can easily be adjusted.• Changing the heating mode linked with time is possible.

Day-Weekly timer setting• The day-weekly timer can be set up for up to 3 times per day.• Allows separate settings for each day of the week.

Holiday timer setting• The holiday timer can be set up for up to 8 periods• If you are absent for a long time in the winter, freezing of room

can be prevented.

The growth of Legionella in DHW tank is suppressed and safe and clean hot water is supplied at all times.

Automatic heating curve control based on outdoor temp and setting room temperature.

Even if hot water temperature is different in 2 heating systems, they can be controlled simultaneously.

System can continuously supply hot water by built in back up heater or boiler, as emergency, even if an error is occurred.

Water circulation and compressor can be automatically performed at low outdoor temperature. Freezing of circulated water can be pre-vented.

If the cooling operation function is set, the system can automatically switch to cooling or heating, depending on the outdoor temperature to provide all-season comfortable air conditioning.

Maintaining the room temperature during defrost operation by boost start operation

comfortable status can be maintained. The backup heater is controlled intelligently just as a security backup for very cold days/nights and only activated when really necessary.

Quick error handling service and maintenance are possible by this function.

Time

ON OFF

High

Low

Outdoor temperature

Anti-freeze mode

Settingtemperature

Radiator

Outdoor unit Hydraulic unit

Boiler*Backup heater

Floor heating

*When additional boiler connected

DHW Tank 300 L

55ºC ~ 75ºC30 ~ 360 min

Heater

Radiator

Floor heating

50°COver

possible

~40°C

2ndCircuit Kit

Peak Cut Function*

2 Stage Low Noise Mode*

This function performs operation by setting a peak current value and reducing the power consumption.

Outdoor unit can be switched to silent mode, depending on the installation environment.(Valid only for High Power)

34

Stage 2

Stage 1Low noise mode

Rated noise value-2dB -4dB

FEATURES

-10 -5 0 5 10 15 20-15

30

40

50

60

-20

Leav

ing

wat

er

Automatic temperature controlwith heating curve

Heating curve off-set: Adjust setting room temp.

Outdoor temperature (°C)Low High

High

Low

+4.5°C

-4.5°C

Setting heating curve

Leav

ing

wat

erte

mpe

ratu

re (

°C)

A program adjusts the hot water temperature automatically in advance based on the outdoor temperature, so hot water temperature can be controlled so that setting temperature is maintained constantly.

Page 11: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

20 21

PRODUCT LINEUP for various needs

-20°CUsable outdoortemperature:

-20°CUsable outdoortemperature:

-25°CUsable outdoortemperature:

Type

Hydraulic indoor unit

Outdoor unit

System

Power source

Capacity range

5 kW

8 kW

10 kW

11 kW

14 kW

1Ø 230 V/50 Hz 3Ø 400 V/50 Hz 1Ø 230 V/50 Hz 1Ø 230 V/50 Hz

Check the validity of label at www.ehpa.org/QL

11/14 kW 10 kW 8/10 kW

temperature

heating, radiators and others.*

• Heating and DHW in one system.*

• Additional electric heater for backup provided.

• Up to two independent control circuits.*

• Solar connection for hot water production.*

• Cascade connection up to three systems.*

• Cooling operation is possible.*

• 55°C hot water supply even at -10°C outdoor temperature

heating, radiators and others.*

• Heating and DHW in one system.*

• Additional electric heater for backup provided.

• Up to two independent control circuits.*

• Solar connection for hot water production.*

• Cascade connection up to three systems.*

• Cooling operation is possible.*

• 55°C hot water supply even at -20°C outdoor temperature

• Heating and DHW in one system.

• Additional base heater can be connected to prevent from freezing.*

• Cooling operation is possible.

Page 12: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

22 23

High Powerseries

FEATURES

Energy Saving

Single Phase power supply

3 Phase power supply

Hydraulic indoor unit

Hydraulic indoor unit

Outdoor unit

Outdoor unit

WOYK112LCTAWOYK140LCTA

11 kW

11 kW

14 kW

14 kW

*

Powerful HeatingHigh Power models realize high leaving water temperature and high heat-ing capacity even at low ambient temperature by newly developed “Linear Control Injection Technology”. It is possible to provide high water tempera-ture and warm rooms in cold regions.

and the optimization of refrigerant cycle control. High Power model

and control technology corresponding to hot water heating.

High Leaving Water Temperature

to -20°C outdoor temperature without using backup heater.

* If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation.

Extended Operation Range Down to -25°CImproved operation range down to -25°C outdoor temperature

heater*

Single Phase 3 PhaseA7W35 condition

High COP

Optimization of refrigerant cycle operation

High Power model realizes high performance and

technology corresponding to hot water heating.Outdoor unit Hydraulic indoor unit

Emitter system

Refrigerant

Hot water

Temperature sensor

Pressure sensor Co-axial Heat Exchanger

Hydraulic indoor units

Outdoorunits

Under floor heatingBalancing vessel(Required optional part)

Pump

Cascade connection

PRODUCT LINEUP

Outdoor temperature (°C)-10-15 -5 0 5

30

-20

60

Leav

ing

wat

erte

mpe

ratu

re (

°C)

High Power model

Page 13: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

FEATURES

Energy Saving

24 25

Hydraulic indoor unit

Hydraulic indoor unit

Outdoor unit

Outdoor unit

WOYA080LFCA

WOYA100LFTA

5 kW

10 kW

8 kW

Comfortseries

Wide Operation RangeImproved operation range down to -20°C outdoor temperature

High COP

Heated up Comfortablysuited for European environment. Hot water temperature can be

and domestic hot water are provided.

Hydraulic indoor units

Outdoorunits

Under floor heatingBalancing vessel(Required optional part)

Pump

DC InverterSmooth water temperature control realized by DC inverter control.

DC Twin Rotary Compressor-

pressor

DC Fan Motor

small DC fan motor mounted.62

0 m

m

830

mm

10 kW5 - 8 kW

Outdoor unit technologyCascade connection (10 kw model)

High Leaving Water TemperatureMaximum leaving water temperature is 55°C without backup heater. Hot water supply temperature can be maintained even at –10°C outdoor temperature.

* If you want to raise the hot water supply temperature, backup heater can be used for the auxiliary operation.

heater*

PRODUCT LINEUP

A7W35 condition

Outdoor temperature (°C)20151050-5

40

30

60

50

-10

Leaving watertemperature (°C) 55

Page 14: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

27

Control box

Outdoor unit

8 kW 10 kW High Performance

High COP 4.50 (8 kW model)

High COP is realized by using a DC twin rotary compressor,

High Leaving Water Temperature

Wide Operation Range

High leaving water temperature of 55°C keeps to -20°C outdoor temperature without additional heater.* If you want to raise the hot water supply temperature, backup

heater can be used for the auxiliary operation.

Improved operation range down to -20°C outdoor temperature

heater*

Compactseries

Heating emitter

Control boxMonobloc unit

Plate heat exchangerAmbient air

CompressorEvaporator

Heating circuit pump

Hot water

All-in-One Model

FEATURES

Energy Saving

Outdoor unit technology

DC Fan Motor DC Twin Rotary Compressor DC Inverter

Plate Heat Exchanger

small DC fan motor mounted. compressorSmooth water temperature control realized by DC inverter control.

Very compact size achieved by a thin

CompactDesign

Weight

72 kg8 kW model

Easy installation &maintenance!

PRODUCT LINEUP

Control box

Outdoor temperature (°C)-10-15 -5 0 5

40

50

60

-20

55

Leav

ing

wat

erte

mpe

ratu

re (°

C)

Page 15: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

28

SYSTEM

& OPTIONAL PARTS

Page 16: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

30 31

Simple operation mode setting• Selecting the heating mode and Domestic hot water operation

Large LCD display• Operation status display• Error display• plain text

Navigation and setting• Selecting the heating menu• Setting program timer

Adaptor for external device Individual Controller

Web server (option)UTW-KW1XDUTW-KW4XD

or

Service Tool (option)

Modbus clip (option)UTW-KMBXE

UTW-KW1XDUTW-KW4XD

Web server (option)Internet

Smartphone control

Home Automation system

Remote control system

Remote ControlUTW-C74TXF*1

UTW-C74HXF*1

HMI Kit (option)UTW-KHMXE

Corresponding to multi languages

or

Wired Remote Control(option)

Wireless Remote Control(option)

Remote ControlUTW-C78XD

Room ThermostatUTW-C58XD

Room ThermostatUTW-C55XA

Software

Service & Maintenance Tool

*1: 19 Languages included,no separate Estern European RC necessary

RF ModuleUTW-MRCXD

LPB clip (option)UTW-KL1XD

UTW-KPSXD*2 UTW-KPSXD*3 *2: UTW-KW1XD or UTW-KW4XD is required for the connection.*3: UTW-KL1XD is required for the connection.

Hydraulic Indoor Unit Controller

Solar connection

Control

Page 17: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

32 33

SYSTEM CONFIGURATION Split type

Controller(Optional Parts)

System Components(Optional Parts)

Heating& Hot Water

(Locally purchased)

Hot Water(Locally purchased)

Boiler(Locally purchased)

Solar(Locally purchased)

DHW Tank

Swimming PoolHeat ExchangerUTW-ESPXA

& Swimming Pool KitUTW-KSPXD*

Floor Heating

Hot Water

Shower

Bath

Radiator

Remote Controller Cable Domestic HotWater

Web server Cable

Gas Refrigerant

*Regulation Extension Kit (UTW-KREXD) is required.

Liquid Refrigerant

Flow pipe Return pipe

or

WiredRemote Control

WirelessRemote Control

Remote ControlUTW-C78XD

Room ThermostatUTW-C58XD

Room ThermostatUTW-C55XA

UTW-KW1XDUTW-KW4XD

Locally purchased

UTW-T20XAUTW-T30XAUTW-T30XD

Basic Unit

Comfort series

Comfort seriesWSYA100DG6

High Power series

High Power seriesWSYG140DG6WSYK160DG9

Outdoor Unit

Hydraulic Indoor Unit

WOYK112LCTAWOYK140LCTAWOYK160LCTA

WOYG112LCTAWOYG140LCTA

Internet

Web-Server

Cascade KitUTW-KCMXE(for master)UTW-KCSXE(for slave)

Fan Coil

Remote ControlUTW-C74TXF

RF ModuleUTW-MRCXD

WOYA100LFTA

WOYA060LFCAWOYA080LFCA

2nd Circuit KitUTW-KZDXD*

Boiler Connection KitUTW-KBDXD

& Balancing VesselUTW-TEVXA

System Case Studies

2 emitter simultaneous heating (Individual control)

2 emitter simultaneous heating & Domestic Hot Water (Cascade)

Boiler connected to heating (Boiler + Heating)

Hydraulic indoor units

Outdoor units

Valve Pump

Pump

Radiator

Hydraulic indoor units

Outdoor units

Valve

Valve Pump

Radiator

Boiler

Pump

Outdoor units

Hydraulic indoor units

Valve Pump

Pump

Balancing vessel (Option)Radiator

Tank

Hot water supply(e.g. for shower)Type

A

Valve

Hydraulic indoor units

Outdoor units

Valve

Valve

Pump

Balancing vessel (Option)Radiator

Tank

Hot water supply(e.g. for shower)

Pump

TypeB

Page 18: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

34 35

System Case Studies

or

WiredRemote Control

WirelessRemote Control

Remote ControlUTW-C78XD

Room ThermostatUTW-C58XD

Room ThermostatUTW-C55XA

Locally purchased

Remote ControlUTW-C74TXF

Controller(Optional Parts)

System Components(Optional Parts)

Heating & Hot Water(Locally purchased)

Hot Water(Locally purchased)

Boiler(Locally purchased)

DHW Tank

Swimming Pool

Heat ExchangerUTW-ESPXA

& Swimming Pool KitUTW-KSPXD*

Floor Heating

or

Hot Water

Shower

Bath

Radiator

UTW-T20XAUTW-T30XAUTW-T30XD

Basic Unit

Fan Coil

Flow pipe Return pipe

Remote Controller Cable

Domestic Hot Water

Web server Cable

1. Only one heating circuit can be connected.2. Only one Controller (Option) can be connected.

Note:

Monobloc Unit

WPYA080LGWPYA100LG

Control box

UTW-SCBYA

UTW-KW1XDUTW-KW4XD

Internet

Web-Server

RF ModuleUTW-MRCXD

Solar(Locally purchased)

Modbus ClipUTW-KMBXE Home Automation

SystemLocally purchased

Floor heating

Outdoor unit

Floor heating

Outdoor unit

Boiler

Valve

Floor heating

Outdoor unit

Valve

Hot water Supply(e.g. for shower)

SYSTEM CONFIGURATION Monobloc type

Single heating system

2 types of heat distribution

Boiler connected to heating (Boiler + Heating)

Page 19: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

37

OPTIONAL PARTS

Product Name

2nd Circuit Kit

BoilerConnection kit

Balancing vessel

DHW kit

Circulating pump

DHW tank

Swimming Pool kit

200 Liter300 Liter

300 Liter

Heat Exchanger for swimming pool kit

Cooling kit

Regulation Extension Kit

Low Noise Kit

Drain Pan

UTW-KZSXE

UTW-KBSXD

UTW-TEVXA

UTW-KDWXG

UTW-KDWXD

UTW-T20XAUTW-T30XA

UTW-T30XD

UTW-PHFXD

UTW-KSPXD

UTW-ESPXA

UTW-KCLXD

UTW-KREXD

UTW-KLNXE

UTW-KDPXA

UTW-KCMXE

UTW-KCSXE

Model Name

Split

High Power

1Ø 3Ø 1Ø

Comfort

11

14

11

14

16

5

6

8

10

Cascade Master Kit(incl. LPB Clip)

Cascade Slave Kit(incl. LPB Clip)

Monobloc

8

—*1

10

—*1

Compact

Split

Product Name Model Name High Power

1Ø 3Ø 1Ø

Comfort

Remote Controller

RoomThermostat

Outdoor SensorTransmitter

Web server

RF Modules

LPB Clip

Base Heater

Service ToolSoftware

External connect kit

Service Tool(incl.OCI700 adaptor)

Zone control kit

UTW-KHMXE*2

UTW-C74TXF*2

UTW-C74HXF*2

UTW-C78XD

UTW-C78XD-E*3

UTW-C55XA

UTW-C58XD

UTW-MOSXD

UTW-MRCXD

UTW-KL1XD

UTW-HAMXE

UTW-KZMXG

UTW-KSTXD

UTW-KPSXD

UTY-XWZXZ2

11

*4

*5

14

*4

*5

11

*4

*5

14

*4

*5

16

*4

*5

5

*4

*5

6

*4

*5

8

*4

*5

10

*4

*5

Wired

Wireless

Wireless

for BSB-Port

Wired

UTW-KW1XDUTW-KW4XD

HMI Kit

Monobloc

8

*4

*5

10

*4

*5

Compact

Optional parts compatibility for system Optional parts compatibility for control

Page 20: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

38

Page 21: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

40 41

Set temperature

Indoor unit

RadiatorValve

Valve

Pump

Pump

Tank

Outdoorunit

Under floor heating

Hot water shower

Indoor unit

Outdoorunit

OuunIndoor unit

Outdoorunit

Under floor heating

Indoor unit

Valve

Pump

Tank

Outdoorunit

Hot water shower

SIMPLE INSTALLATION & MAINTENANCE

Easy Installation & Maintenance

Maintenance Support

• All hydraulic safety & controlling components built in, no additional selection required

• Easy access for maintenance operations

• No installation of refrigerant circuit connections (Only Monobloc)

• Refrigerant pump down operation

Diagnotics function for trouble shooting

Controller features a large LCD display and buttons to make setting functions easy

Easy pre-setting 8 pattern systems (Duo heating : 12 patterns)

Outdoor temperature simulation

Floor drying

When installed, the controller makes it simple to set system settings without having to individually set the system’s components and units.

It can be checked whether each unit operates correctly under the set conditions and expected outdoor temperatures when the system is actually assembled.

Outdoor temperatures in the range from –50°C to +50°C can be simulated.

• DHW & solar control auto detection• pool heating & cooling optional

Pre setting 1 1 heating circuit

Pre setting 2 2 heating circuit

Pre setting 3 1 heating circuit & boiler backup

Pre setting 4 2 heating circuit & boiler backup

Pre setting 5 1/2 heating circuit & buffer control

1/2 heating circuit & buffer control & boiler backup

Pre setting 7 cascade connection Master

Pre setting 8 cascade connection A

Hydraulic Indoor unit

Radiator

Valve

Pump

Outdoorunit

Under floor heating

Pump

Flow Chart Example Item

User Setting Date and time, time program, Operation temperatur settingEnd users

Installers

workoutSetting Outdoor temperature simulator

ConvenientFunction

Automatic Heating curve setting, Floor controlled driving,Outdoor temperature adjiustment, Maintenance period srtting

Option Setting Cooling kit, DHW kit, Boiler kit, Swimming pool kit

Install Setting Pump speed setting,Configuration. Heating curve setting, Heat pump shout off

Confirmation Operation conform(Heating cooling, DHW, option,)

Display of all segments operation mode indicateLarge display

Simple setting

Error display

Hydraulic indoor unit error Outdoor unit error

Error symbol appearson the controller

When an error is occuring

Error codeError designationClear text info (UART)

Confirm flashing times Confirm blink code for error code indication

LED2(GEEN)LED1(RED)

Detailed information will be displayed

Check the error code table

i

press “Info”button

tton“Info” bu

When an error is occurring green and red LED flash along with error cause

When an error is occurring

: ON

: Blinks rapidly

POWER

MODE

ERROR

How to know which error has appeared

surrounding the hot water piping more quickly to shorten the construction period.

Page 22: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

42 43

INSTALLATION INFORMATION

Power supply cable to the electrical back-ups cable DHW power supply

cable

Interconnection between the outdoor unit and the hydraulic unit Phase, Neutral, Earth, Communication bus cable

Power supply cable

Electric panel

Remote control (option)

Room thermostat (option)

Remote control (option)

Room thermostat (option)or

or

or

Hydraulic unit

Outdoor sensor

Hydraulic indoor unit

Electrical Wiring Electrical Wiring

• Hydraulic unit is to be hang on the wall

• Distances for maintenance should be respected

Outdoor unit• Floor stand• Weight < 71 kg (without water)• Distances for maintenance should be kept

120 mm600 mm

120 mm

600 mm

300 mmmini 1000 mm

350 mmmini

Power supply cable

Outdoor sensorcable 2 x 0.75 mm2

Interconnection between the outdoor unit and the hydraulic unit Phase, Neutral, Earth, Communication bus Cable 4 x 1.5 mm2

Control box(UTW-SCBYA)

Remote control (option) :cable 3 x 0,5 mm2

Room thermostat (option) :cable 2 x 0,5 mm2

Remote control (option)

Room thermostat (option)

or

or

or

Electric panel

Page 23: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

44 45

Outdoor Unit Outdoor Unit Hydraulic Indoor Unit

450

800

832,

8

97 98

Heating return Ø25.4

Heating flowØ25.4

457 81

479

650

400

1290

900

21

33031 1277

1290

900

21

33031 12

650

400

Front view Side view

Front view

Top view

Front view

Top view

Side viewSide view

352

45.4

320

395

540 125

Drain port Ø20

20 790

620

20

62 290

Outdoor Unit Outdoor Unit Hydraulic Indoor UnitWOYA100LFTA

450

800

832,

8

97 98

Heating return Ø25.4

Heating flowØ25.4

457 81

479

77900

830

21

33031 12

650

400

Front view Side view

Front viewFront view

Top viewTop view

Side viewSide viewSide view

SPECIFICATIONS & DIMENSIONS Split type

(High Power series) (Comfort series)

Dimensions (High Power series) Dimensions (Comfort series)

11 14 11 14

7°C/35°C floor heating *Heating capacity

kW10.80 13.50 10.80 13.50 15.17

Input power 2.54 3.23 2.51 3.20 3.70COP 4.25 4.18 4.30 4.22 4.10

2°C/35°C floor heating *Heating capacity

kW10.77 12.00 10.77 13.00 13.50

Input power 3.44 3.87 3.40 4.15 4.34COP 3.13 3.10 3.17 3.13 3.11

-7°C/35°C floor heating*Heating capacity

kW10.38 11.54 10.38 12.20 13.50

Input power 4.32 5.08 4.28 5.13 5.40COP 2.40 2.27 2.43 2.38 2.50

Temperature application °C 55 35 55 35 55 35 55 35 55 35Energy efficiency class A+ A++ A+ A+ A+ A++ A+ A++ A+ A+Rated heat output(Prated) kW 11 11 13 11 11 13 13 14Seasonal space heating energy efficiency( S) 151 113 148 112 154 117 150 117Annual energy consumption kWh 8041 7803 7408

Sound power levelHydraulic indoor unit

Outdoor unit 70 71

Power source 1 Ø 230 V 50 Hz 3 N 400 V 50 HzDimensions H×W×D mm 800 × 450 × 457Weight (Net) kg 42Water circulation Min/Max L/min 24.4/48.7 24.4/48.7 27.4/54.8

LExpansion vessel capacity L 8Leaving water temperature range Max °CWater pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4

Capacity kW

Power source 1 Ø 230 V 50 Hz 3 N 400 V 50 HzCurrent Max A 22.0 25.0 8.5 10.5Dimensions H × W × D mmWeight (Net) kg

R410A (2,088)Refrigerant amount kg 2.50Additional refrigerant charge amount g/m 50

Connection pipe

DiameterLiquid

mmØ 15.88

Length Min/Max m 5/20Length(Pre-charge) m 15Height difference Max m 15

Operation range Heating °C -25 to 35

6 8

7°C/35°C floor heating *Heating capacity

kW4.50 7.50 10.00

Input power 1.41 1.84COP 4.52 4.27 4.08 4.02

2°C/35°C floor heating *Heating capacity

kW4.50 7.70

Input power 1.53 1.78 2.47COP 3.24 3.24 3.17 3.12

-7°C/35°C floor heating*Heating capacity

kW4.10 5.70 7.40

Input power 1.47 1.74 2.23COP

Temperature application °C 55 35 55 35 55 35 55 35Energy efficiency class A+ A++ A+ A++ A+ A++ A+ A++Rated heat output(Prated) kW 4 4 5 5 7 8 8Seasonal space heating energy efficiency( S) 115 115 118 113 155Annual energy consumption kWh 3180 2505 3375 5415 4415

Sound power levelHydraulic indoor unit

Outdoor unit

Power source 1 Ø 230 V 50 HzDimensions H×W×D mm 800 × 450 × 457Weight (Net) kg 42Water circulation Min/Max L/min 10.8/21.7 13.5/27.1

LExpansion vessel capacity L 8Leaving water temperature range Max °C 55Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4

Capacity kW

Power source 1 Ø 230 V 50 HzCurrent Max A 11.0 12.5 17.5 18.5Dimensions H × W × D mmWeight (Net) kg 41 42

R410A (2,088)Refrigerant amount kg 1.10 1.40 1.80Additional refrigerant charge amount g/m 25 40

Connection pipe

DiameterLiquid

mmØ 12.70 Ø 15.88

Length Min/Max m 5/30Length(Pre-charge) m 15Height difference Max m 20

Operation range Heating °C -20 to 35

Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.

-ucts/erp-ecodesign/index.html.

Page 24: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

47

SPECIFICATIONS & DIMENSIONS Monobloc type

8

7°C/35°C floor heating *Heating capacity

kW8.00 10.00

Input power 1.78 2.30COP 4.50 4.35

2°C/35°C floor heating *Heating capacity

kW4.35

Input power 1.23 1.44COP 3.55 3.40

-7°C/35°C floor heating*Heating capacity

kW7.10 8.00

Input power 3.32COP 2.42 2.41

Temperature application °C 55 35 55 35Energy efficiency class A+ A++ A+ A++Rated heat output(Prated) kW 7 7 8 Seasonal space heating energy efficiency( S) 123 118 Annual energy consumption kWh 3828 3580 3700 Sound power level Outdoor unit

Power source 1 Ø 230 V 50 HzDimensions H × W × D mm 882 × 850 × 330Weight (Net) kg 72Current Max A 15.2 17.5Water circulation Min/Max L/min 10.0/30.0Water pipe connection diameter Flow/Return mm Ø 25.4/Ø 25.4Refrigerant R410A (2,088) Refrigerant amount kg 1.72Leaving water temperature range Max °C 55Operation range Heating °C -20 to 35

Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined values and these values.

-ucts/erp-ecodesign/index.html.

240

436152

171

540155 155

75 70

330

480

173

882

357

850

Dimensions

Outdoor Unit Control box

Front view

Top view

Side viewSide view

Page 25: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

48

Estimate function

Software updates

MODEL SELECTION SOFTWARE

• The software automatically selects the equipments just by inputting some factors, like the region where the equipment is installed, required capacity to heat up the space, and a heating method.

• The transition in the equipment capacity at each outdoor tem-perature condition and/or when back up heater is under operation can be easily created by this software.

The software automatically provides graphs of monthly running cost, CO2 emission volume, cost comparison against other heating sources, and other data to allow the users to see at a glance the

the units are selected. And by seeing the images and the list of equipments at the same time, it avoids mistake in the selection of equipments.

• The visible images of the optional items enables the correct

• All of the associated optional items are automatically chosen in a

equipments.

The software automatically provides the cost estimate of the entire

optional items.

Various kinds of documents such as an equipment list, a system diagram, a cost estimate table, and an equipment CAD data can

comes with a feature which allows you to change the template design of the documents.

The database can be automatically updated through FTP by auto-matic update function.

Model selection with detailed technical information

Page 26: Innovative Solution of Domestic Heating - Fujitsu · 2016-06-13 · Direct electrical heating 278% 117% 109% 79% Primary Energy Consumption* Fuel boiler Gas condensing boiler ...

Fujitsu General ((Thailan )d) Co., Ltd.

ISO 9001Certified number : 01 100 89394

ISO 14001Certified number : 01 104 9245/01

Fujitsu General ((Shanghai)) Co., Ltd.

ISO 9001Certified number : 01 100 79269

ISO 14001Certified number : CNBJ31115

7EF01 -160 E

3-3-17, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japanhttp://www.fujitsu-general.com/

Copyright© 2009-2014 Fujitsu General Limited. All rights reserved.

・Specifications and design are subject to change without notice for future improvement.・For further details, please check with our authorized dealer.・The products or equipment in this catalogue contain fluorinated greenhouse gases.・“  ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas.・Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.

・Actual product's colors may be different from the colors shown in this printed material.Distributed by :

Room Heating

Domestic Hot Water

Swimming Pool

Cooling

and much more ...

3-UK