RCI Inspection # 2015June01-01-Client 1 of 40 435.275.9204 [email protected] Commercial | Residential | Property | Insured | Certified General Residential Inspection Report 435.275.9204 | [email protected] www.RedCliffInspections.com | www.FaceBook/RedCliffInspections Client: Jack Client 435-555-5555 Agent: Joe Realtor Acme Reality 435-555-5555 Inspector: Jim Fugate 435.275.9204 500 So. Anystreet, Washington, Utah June 1, 2015
Transcript

RCI Inspection # 2015June01-01-Client 1 of 40

[email protected]

Commercial | Residential | Property | Insured | Certified

General Residential Inspection Report

435.275.9204 | [email protected] | www.FaceBook/RedCliffInspections

Client: Jack Client

435-555-5555

Agent: Joe Realtor Acme Reality

435-555-5555

Inspector: Jim Fugate

435.275.9204

500 So. Anystreet, Washington, Utah June 1, 2015

RCI General Residential Inspection Report

[email protected] 2 of 40

[email protected]

'Click' blue text to go to section

Preface/Introduction

REPORTGeneral Property Description and ConditionsElectrical ServiceWater Service

Utility Services

Sewer ServiceGas ServiceExterior

Structure & Exterior

FoundationRoofAtticHeating System(s)Cooling System(s) Mechanical SystemsWater HeaterGarage/Carport (attached)PantryLaundry RoomKitchenDining RoomHallway(s)/Stairwell(s)

Living Spaces

Bathroom(s)Bedroom(s)

Other Room (over Garage)

Report Summary

Grounds

Exterior of HomeBalcony/Patio/Deck

Exterior Structure(s) (e.g. garage, shed)

Table of Contents

Front/Living/Family Room(s)

About this Inspection

This Report not a WarrantyGlossary of Terms and Abbreviations

Use of Infrared Imaging

RCI General Residential Inspection Report

[email protected] 3 of 40

[email protected]

Click here to go to the Table of Contents

Continued on next page

Preface/IntroductionIt is important to read all of the information in this report to gain a complete picture of the inspectors findings. If you have questions please do not hesitate to contact RCI during regular business hours. About This Inspection: Red Cliff Inspections (RCI) is certified by the International Association of Certified Home Inspectors (InterNACHI) and RCI's inspections are equal to or exceed the standard set by the InterNACHI Standards of Practice (SOP). The InterNACHI SOP can be found at http://www.nachi.org/sop.htm or RCI can provide a copy. This report is an account of an impartial, time limited, visual, and non-destructive inspection. During the inspection the inspector does not disassemble any equipment or structure, move any personal property, apply stress to any object or structure, turn on any major system or component that is off, and/or do any destructive testing. The inspector does not turn electrical breakers on or off, and does not turn service plumbing valves at any time. Areas or items that are hidden, not readily visible, or that are not accessible, are not inspected or covered in this report. Some items or areas may not be checked because of one of the following factors: the item was disconnected or not accessible, was not visible, exhibited improper or unsafe conditions for inspection, was outside the scope of the inspection, and/or was not inspected due to other factors, stated or otherwise. This report does not include all items covered in the Real Estate transfer disclosure statement. An attorney and/or other related professional should be consulted on additional items not included in this report. Use of Infrared Imaging: Red Cliff Inspections includes infrared (IR) imaging as a part of our residential home inspections. This service exceeds the InterNACHI SOP and improves the inspectors ability to assess the conditions in the home. It also increases the depth and quality of service provided to the client. RCI's use of IR as a part of a residential home inspection does not constitute an 'energy audit'. Thermal imaging, or IR, is a better diagnostic tool than the human eye alone, however it can not guarantee 100% accuracy. When possible, other tools are used to verify what is detected by IR images. The efficacy of thermal imaging is affected by environmental conditions (e.g. ambient interior and exterior temperatures, construction materials and techniques, and etc..). Therefore, not all issues that can be detected with IR will be found every time IR is used. This Report is not a Warranty: This inspection identifies conditions at the time of the inspection. Conditions which are considered normal may not be noted in the report. This report is not a guarantee or warranty on the condition of the property or its contents, or changes which may occur following the inspection. RCI only warrants that an inspection for a standard residential home inspection and report will be performed in accordance with scope and Standards Of Practice (SOP) of the International Association of Certified Home Inspectors (InterNACHI). A copy of the InterNACHI SOP is available at http://www.nachi.org/sop.htm

RCI General Residential Inspection Report

[email protected] 4 of 40

[email protected]

Click here to go to the Table of Contents

Preface/Introduction (continued)

Glossary of Terms and Abbreviations: The following are found in the 'Condition Columns' (marked with an 'x' or numeral as appropriate) NP: (Not Present) The item is not present or not visible at the time of the inspection. G: (Good) In good condition and/or operating normally. F: (Fair) In fair condition and/or operating, but has a defect or may soon develop a defect, that may require repair or replacement. P: (Poor) Needs immediate attention or repair, and maybe unsafe; may not be functioning, have a defect, or be in a condition with high probability of developing a defect. The following abbreviations may be found in the 'Comments' section and elsewhere in the report narrative: COS or Cosmetic: Damage or deterioration that does not affect function or purpose. Exception: Issue that is an exception to a condition rating that does not lower the overall rating. General Note(s): Conditions that pertain to more than one area of the property, system, or space being inspected. GFI, AFCI, or GFCI: Ground or Arc Fault Circuit Interrupter. Electrical outlet or breaker designed to prevent electrical shock. IR: Infrared or Thermal. In this report IR will usually refer to the use of infrared or thermal imaging. LE : This symbol is a hyperlink to the 'InterNACHI Standard Estimated Life Expectancy Chart for Homes' found online. PSI: Pounds Per square Inch. A measurement of pressure. NOTE(S): Additional information that is relevant to the listed item. NFAH: Normal For Age of Home. Generally refers to minor or cosmetic damage or deterioration that is commonly present with a home of the age being inspected. NTBS: Not To Building Standard. The condition may exist as a result of damage, renovation, omission, or was constructed prior to the establishment of a specific code requirement. The issue is often incidental and NFAH, and may, or may not, require repair or replacement. TPRV: Temperature Pressure Relief Valve. Water heater valve designed to relieve pressure & prevent explosion.

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 5 of 40

[email protected]

Click here to go to the Table of Contents

General Property Description & ConditionsComments

Date of Inspection June 13, 2015Time of Inspection 08:30 - 12 noon on SitePresent at Inspection Jim Fugate (RCI Inspector), Jack & Jill Client (Buyers)Weather

Sunshine/Cloudy Sunny

Temperature (exterior) 70-80 F

Precipitation Clear - Dry

Wind Calm

Dwelling Type Single Family Home

Sq Ft of Home 2314Year Home Constructed 2003

Topography around home Mostly flat with gentle slopes away from home foundation

General Note(s)

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 6 of 40

[email protected]

Click here to go to the Table of Contents

Electrical Service NP G F P Comments LEElectrical Service Entrance

Location x outside on west

Overhead/Underground x Underground

Meter Location Outside on west exterior

Meter Condition x

Service Amps-Volts x 200Ground/Bond x

Main Shut-off Location Outside on west exterior

Main Panel Location interior at garage

Manufacturer/Condition x cutler hammerCover x

Wiring x

Feed Conductor Type x Appears to be Aluminum

Branch Conductor Type x Appears to be Copper

Breakers/Fuses x Breakers

Sub-Panel Location At exterior entertainment area structure

Manufacturer/Condition x EatonCover x

Wiring x

Feed Conductor Type x Appears to be Copper

Branch Conductor Type x Appears to be Copper

Breakers/Fuses x Breakers

General Note(s)

View of panel interior and IR of panel (note the GFI breaks run a bit warmer and are normal)

View of Meter with Master Shut Off & Main Panel -continued on next page

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 7 of 40

[email protected]

Interior of Sub PanelSub Panel

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 8 of 40

[email protected]

Click here to go to the Table of Contents

Water Service NP G F P Comments LE

Water-Municipal/Private Municipal

Supply Line(s) xCopper- Lines are not fully visible. No leaks were visible at the time of the inspection.

Water Pressure x 80 psiMain Supply Shut-Off x Closet in garage

Non-potable System Present, but not surveyed as a part of this inspection

Main water shut offWater pressure reading on exterior hose bib

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 9 of 40

[email protected]

Click here to go to the Table of Contents

Sewer Service NP G F P Comments LEWaste-Municipal/Private Municipal

Waste Line(s) xRigid Plastic- Lines are not fully visible. No leaks were visible at the time of the inspection.

General Note(s) System appeared to be functioing normally at the time of inspection.

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 10 of 40

[email protected]

Click here to go to the Table of Contents

Gas Service NP G F P Comments LEMeter Location Outside on west exterior

Main Shut off Location Outside on west exterior

General Note(s)

Gas meter and shut off

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 11 of 40

[email protected]

Click here to go to the Table of Contents

Exterior

Exterior - Home NP G F P Comments LEExterior Wall(s) Construction x Wood Frame

Exterior Covering (Siding) 1 x Brick

Exterior Covering (Siding) 2 x Stucco

Exterior Covering (Siding) 3 x Vinyl Note: Exterior rear shows shrinking of vinyl

Column(s) x

Lighting x

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

General Note(s)

View of rear yard

Exterior - Balcony/Deck/Patio

NP G F P Comments LE

General DescriptionFloor x Concrete

Stairs x

Roof/Ceiling x

Ledger x

Supports/Posts/Beams x

Lighting x

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

General Note(s)

Vinyl shows shrinking

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 12 of 40

[email protected]

Exterior - Grounds NP G F P Comments LE

Driveway x Concrete

Sidewalks x Concrete - Exception: minor cracking

Sidewalk Steps x

Vegetation x

Column(s) x

Fence/Wall xBlock - still being constructed (top stones and gates still incomplete)

Gate(s) x

Grading/Drainage x

Lighting x

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

General Note(s)

Exterior - Structure(s) NP G F P Comments LELocation Located at rear of home- an entertainment area

Exterior

Example of minor cracking

View of Patio off of dinning room

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 13 of 40

[email protected]

Exterior Wall(s) x

Exterior Covering Type (1) x Brick

Exterior Covering Type (2) x Vinyl

Foundation x

Drainage x

Roof x

Doors xGFI/AFI/AFCI x

Fireplace x Flue had minor creosote buildup, damper OKGeneral Note(s)

Views of Exterior Structure

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 14 of 40

[email protected]

Click here to go to the Table of Contents

Foundation NP G F P Comments LEType Slab

Material Concrete

Condition x

Drainage/Grading x

Comment(s)

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 15 of 40

[email protected]

Click here to go to the Table of Contents

Roof NP G F P Comments LEType Combination Hip and Gable

Pitch Roof slops vary on different sections of the roof.

Roof Covering Material 1 Concrete tile

Roof Covering Material 2

Chimney(s)/Vents/Etc.. x

Flashing x

Eves/Soffit x

Gutters x

Downspouts x

General Note(s) xNoted several tile that had shifted and need to be reset. Most all are near ridges/peaks on the roof.

Roof Pitch at two locationsView of one of the displaced roof tiles

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 16 of 40

[email protected]

Click here to go to the Table of Contents

Attic NP G F P Comments LEAccess Location

Access xPull-down stairs and though room* above garage (*see notes on other room)

Structurex

Unfinished- Truss construction. Note: Limited inspection due to access and type of construction. Note: Limited visibility of components due to type of construction and/or insulation coverage.

Ventilation x Other static vents

Insulation x Loose Fill insulation. Appears adequate. Measured at 10 in depth.

Ductwork x No issue(s) observed. (see Attic visibility/access notes)

Lighting x Lights functioned normally at the time of the inspection.

Electrical x No issue(s) observed. (see Attic visibility/access notes)

Plumbing xNo active leak observed at time of inspection. (see Attic visibility/access notes)

General Note(s)

views of attic access and interior of attic

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 17 of 40

[email protected]

Click here to go to the Table of Contents

Heating System(s) NP G F P Comments LEUnit Location Inside at attic

System Type Natural Gas Forced Air

Manufacturer/Age International Comfort Products/2004Nomenclature See photo of nomenclature from unit.

Electrical x

Filter (s) x

Register(s) x Inflow at 74 - outflow about 95Thermostat x Inside at hall to master bed

Gas x

Enclosure x

Combustion Air x

Gas Line x

Gas Valve x

Emergency Shut -off x

Vent/Flue x

General Note(s) Appears to function normally

Unit InteriorThermostat and Drain Pan under unit -continued on next page

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 18 of 40

[email protected]

Nomenclature

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 19 of 40

[email protected]

Click here to go to the Table of Contents

Cooling Systems NP G F P Comments LEUnit Location Compressor located at west side. Air handler inside in attic.

System Type Central System/Integrated with Heat system

Manufacturer/Age ICP manufacture/Sep 2004Nomenclature See photo of nomenclature from unit.

Electrical x

Filter x

Register(s) x output between 57 and 61 degreesThermostat x Inside at hallway to master bed

Whole House Fan x

Evaporative Cooler x

Window or Portable Units x

General Note(s) NOTE: Compressor fins clogged with debris. Should be cleaned.

IR Views of whole unit - Clogged right side fins - Interior of compressorNomenclature

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 20 of 40

[email protected]

Click here to go to the Table of Contents

Water Heater NP G F P Comments LEUnit Location Inside closet in garage

System Type Gas

Manufacturer/Age Rheem/2005Capacity (e.g. Gallons) 50Plumbing x No evidence of leaks at time of inspection.

TPRV x Present - no leaks observed at the time of inspection

Overflow x

Electrical x

Base x

Insulation Wrap x

Earthquake Strapping x

Gas x

Enclosure x

Combustion Air x

Gas Line x

Gas Valve x

Emergency Shut -off x

Vent/Flue x

General Note(s) There is a water softener in the same closet as the water heater. Function of this unit is not a part of this inspection. No leaks present at the time of inspection.

View of Water HeaterNomenclature

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 21 of 40

[email protected]

Click here to go to the Table of Contents

Garage/Carport NP G F P Comments LE

Location Attached - east side

General DescriptionExterior x see notes on home exteriorDrainage x

Roof x see notes on home exteriorAttic Space x see notes on home exteriorCeiling x

Walls x

Floors x Concrete

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x

Plumbing/Drains x

Garage Door x

Hardware x

Springs x

Opener x

Infrared Sensors x

Fire Wall x Self closing hardware on door to interior not functioningSmoke/CO Detector x

General Note(s)

Views of garage interior

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 22 of 40

[email protected]

Click here to go to the Table of Contents

Pantry NP G F P Comments LELocation Inside at hallway near kitchen

Ceiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows x

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

General Note(s)

View of Pantry

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 23 of 40

[email protected]

Click here to go to the Table of Contents

Laundry Room NP G F P Comments LELocation Inside at hallway from office

Ceiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows x

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

Dryer Vent x

Supply Plumbing x No evidence of leaks at time of inspection.

Waste Plumbing x No evidence of leaks at time of inspection.

Cabinets x

Sink x

Faucet x Normal Flow. No evidence of leaks at time of inspection.

Supply Line(s) x No evidence of leaks at time of inspection.

Waste line x No evidence of leaks at time of inspection.

Gas Line & Valve x

Ceiling Fan x

Smoke/CO Detector x

General Note(s)

Views of Laundry Room -continued on next page

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 24 of 40

[email protected]

Drain and Supply for washerGas Line

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 25 of 40

[email protected]

Click here to go to the Table of Contents

Kitchen NP G F P Comments LE

Ceiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows x

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

AppliancesDishwasher

xComplete operational check is not always possible during the inspection due to time constraints. No leaks were observed during the inspection.

Drain loop/Air Gap x

Disposal x

Trash Compactor x

Microwave xAppeared to operate normally at the time of inspection. (timers and electronics not tested)

Stove Top x Gas. Appeared to operate normally at the time of the inspection.

Vent/Hood x Operating properly at the time of the inspection.

Oven x Gas. Appeared to operate normally at the time of the inspection.

Refrigeratorx

Appeared to operate normally at the time of inspection. (timers, electronics, ice makers, moisture and humidity controls (etc…)and water dispensers not tested)

Cabinets x

Counter tops x

Sink x

Faucetx

Normal Flow. No evidence of leaks at time of inspection. NOTED: The off position does not stop flow completed. Handel must be moved to the right to stop flow completely.

Hand Sprayer x Normal Flow. No evidence of leaks at time of inspection.

Supply Line(s) x No evidence of leaks at time of inspection.

Waste line x No evidence of leaks at time of inspection.

Smoke/CO Detector x

Ceiling Fan x

General Note(s)-continued on next page

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 26 of 40

[email protected]

IR view of stove top

Views of Kitchen

IR view of oven

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 27 of 40

[email protected]

Click here to go to the Table of Contents

Dining Room NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x Sliding Glass Door

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Fire Place x

Ceiling Fan x

Smoke/CO Detector x

General Note(s)

View of Dinning Room

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 28 of 40

[email protected]

Click here to go to the Table of Contents

Hallways/Stairwells NP G F P Comments LECeiling x

Walls x

Floors x

Stairs x

Handrails/Balusters x

Doors (exterior) x

Doors (interior) x

Windows x

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Ceiling Fan x

Smoke/CO Detector x Functioned normally at the time of inspection.

General Note(s)

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 29 of 40

[email protected]

Click here to go to the Table of Contents

Bathrooms

Master Bathroom NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

Ceiling Fan x

Smoke/CO Detector x

Cabinets x

Counter tops x

Sink x

Faucet x Normal Flow. No evidence of leaks at time of inspection.

Stopper x

Supply Line(s) x No evidence of leaks at time of inspection.

Waste line x No evidence of leaks at time of inspection.

Tub xNormal Flow. No evidence of leaks at time of inspection. Whirlpool/spa function is normal

Shower xNormal Flow. No evidence of leaks at time of inspection. NOTE: Inspector could not get auxiliary side flow heads to function.

Shower Walls x

Shower Enclosure x Curtain- not inspected.

Toiletx

No visible leaks, flush operation normal, at the time of inspection. However, moisture meter indicated floor near bathroom has high moisture reading. Recommend further investigation by qualified contractor.

Exhaust Fan x

General Note(s)

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 30 of 40

[email protected]

Moisture meter in alarm at base of toilet

Bathroom (East side) NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

Ceiling Fan x

Smoke/CO Detector x

Cabinets x

Counter tops x

Sink x

Faucet x Normal Flow. No evidence of leaks at time of inspection.

Stopper x

Supply Line(s) x No evidence of leaks at time of inspection.

Waste line x No evidence of leaks at time of inspection.

Tub x Normal Flow. No evidence of leaks at time of inspection.

Shower x Normal Flow. No evidence of leaks at time of inspection.

View of Bathroom (Tub/Sink)

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 31 of 40

[email protected]

Shower Walls x

Shower Enclosure x Curtain- not inspected.

Toilet x No visible leaks, flush operation normal, at the time of inspection.

Exhaust Fan x

General Note(s)

Bathroom (3/4 on west side)

NP G F P Comments LE

Ceiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Present and functioning normally.

Ceiling Fan x

Smoke/CO Detector x

Cabinets x

Counter tops x

Sink x

Faucet x Normal Flow. No evidence of leaks at time of inspection.

Stopper x

Supply Line(s) x No evidence of leaks at time of inspection.

Waste line x No evidence of leaks at time of inspection.

Tub x

Shower x Normal Flow. No evidence of leaks at time of inspection.

Shower Walls x

Shower Enclosure x

Toiletx

No visible leaks, flush operation normal, at the time of inspection. Moisture meter shows increased moisture levels next to toilet base. Recommend review by qualified contractor.

Views of East side bathroom

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 32 of 40

[email protected]

Exhaust Fan x

General Note(s)

View of moisture meter in alarm at base of toiletView of West Side 3/4 bath

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 33 of 40

[email protected]

Click here to go to the Table of Contents

Bedrooms

Master Bedroom NP G F P Comments LECeiling x

Walls x

Floors x

Closet x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Tied to Breaker located in main panel - sub panel.

Ceiling Fan x

Smoke/CO Detector x Functioned normally at the time of inspection.

Fireplace x GasGeneral Note(s)

View of Master Bedroom

Bedroom 2 (NW side) NP G F P Comments LECeiling x

Walls x

Floors x

Closet x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 34 of 40

[email protected]

GFI/AFI/AFCI x Tied to Breaker located in main panel - sub panel.

Ceiling Fan x

Smoke/CO Detectorx

Functioned normally at the time of inspection. NOTE: Not networked with other detectors in the home. Also noted that after testing the detector began to chirp (low battery?)

General Note(s)

Bed Room/Weight Room NP G F P Comments LECeiling x

Walls x

Floors x

Closet x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical xGap next to cover plate at east wall. May be a safety issue. Consult qualified contractor and repair or replace as needed.

GFI/AFI/AFCI x Tied to Breaker located in main panel - sub panel.

Ceiling Fan x

Smoke/CO Detector xFunctioned normally at the time of inspection. NOTE: not networked to other detectors.

General Note(s)

View of East Side Bedroom

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 35 of 40

[email protected]

View of Gap next to cover plate

Bedroom 4/office NP G F P Comments LECeiling x

Walls x

Floors x

Closet x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

GFI/AFI/AFCI x Tied to Breaker located in main panel - sub panel.

Ceiling Fan x

Smoke/CO Detector x Functioned normally at the time of inspection.

General Note(s)

View of bedroom/weight room

View of bedroom/office

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 36 of 40

[email protected]

Click here to go to the Table of Contents

Front/Family/Living Rooms

Front NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Fire Place x

Ceiling Fan x

Smoke/CO Detector x

General Note(s)

Family NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Fire Place x GasCeiling Fan x

Smoke/CO Detector x

General Note(s)

View of front room

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 37 of 40

[email protected]

view of family room

Residential Home Inspection Report

RedCliffInspections.comFacebook.com/RedCliffInspections 38 of 40

[email protected]

Click here to go to the Table of Contents

Other Room NP G F P Comments LECeiling x

Walls x

Floors x

Doors (exterior) x

Doors (interior) x

Windows xOpened properly and showed no evidence of broken internal window seal (moisture, fogging, etc.) at the time of inspection.

Lighting x Lights functioned normally at the time of the inspection.

Electrical x

Fire Place x

Ceiling Fan x

Smoke/CO Detector x

General Note(s) Space accessed by Pull Down Attic Stairs.

views of room over garage

Summary: Residential Home Inspection and Testing

RedCliffInspections.comFacebook.com/RedCliffInspections 39 of 40

[email protected]

Click here to go to the Table of Contents

LE

General Comments:

Comments on items rated " Fair " in the above report:

Comments on the items rated " Poor " in the above report

Helpful Online ReferencesHome Inspections and Home Inspection Reports:Standard Estimated Life Expectancy Chart for Homes http://www.nachi.org/life-expectancy.htmWhat Really Matters in a Home Inspection http://www.nachi.org/what_really_matters.htmLimitations of a Home Inspection http://www.nachi.org/limitations-home-inspection.htmInterNACHI Standards of Practice for General Home Inspection http://www.nachi.org/sop.htm

End of Report Summary

Report Summary

No comment. Home is in good , to very good, condition overall. The exceptions are noted below.

The condition of these items is not unusual and should be considered normal wear and tear on a home of this age: These items should be reviewed further, and may be replaced or repaired, if deemed necessary after review by a qualified contractor: -Shrinking of vinyl siding at rear of home - Shifted roof tile - Self closing hardware on interior door to home from garage - Kitchen faucet does not shut of at 'neutral' position and must be shifted slightly to the right to stop water flow - Smoke detectors in bedrooms on north (bed 2 and weight room) are not networked into the rest

Items rated poor have ceased to function, are not functioning normally, are about to fail, or are a safety hazard, and are in need of repair or replacement: - Gap next to electrical cover plate in weight room/bedroom - Moisture meter detected high levels of moisture at base of toilets in master bath, and 3/4 bath (this may be nothing more that a wax seal needing replacement, but it is important that it be corrected in a timely manner ) - Chirping smoke detector in NW (bed 2) bedroom

The following is a summary of the above Residential Inspection Report. Comment on additional testing may also be made in this summary. The client should consult their real estate professional, and may contact the inspector, if they have questions about the findings noted above report or the summary.

Summary: Residential Home Inspection and Testing