Porter's Wisconsin Inspections, LLC
6938 Otter Creek Rd.
Avoca, WI 53506
Ph#: (608) 583-6024
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
Doc #: 0000 Inspector: Warren Porter
Date: 6/1/2010
Dwelling Address: 923 Somewhere St.
Small Town, WI
Client Name: John Homebuyer 608-000-0000
337N. Any Avenue
Hometown, WI
Client's Agent: Mike Realtor 608-000-0000 Real Estate Company: Pick A Realty
The inspection agreement and contract is a separate document presented at the time of this inspection or prior if Client is not
to be present and is included as a part of this report for the Client and this Inspector. This inspection is not considered
complete till the agreement is signed by the Client. This report is not to be sold or transferred or used by another party unless
permission is granted by the Client. The only purpose for this report in the hands of the Realty professional is to assist the
Client with negotiations with the Seller and this report is not to be shared with other individuals such as other potential buyers.
Page 2 of 20
Porter's Wisconsin Inspections, LLC
6938 Otter Creek Rd.
Avoca, WI 53506
Ph#: (608) 583-6024
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
TABLE OF CONTENTS SECTION PAGE
DEFINITION OF TERMS ................................................................................................................................... 3
GENERAL INFORMATION............................................................................................................................... 3
GENERAL CONDITIONS ................................................................................................................................... 4
Roofs & Chimneys.................................................................................................................................................... 4
Grounds & Deck....................................................................................................................................................... 6
Walls & Gutters........................................................................................................................................................ 8
Garage ....................................................................................................................................................................... 9
Heating/Cooling .................................................................................................................................................... 10
Basement..................................................................................................................................................................11
General Plumbing .................................................................................................................................................. 12
Water Heater ..........................................................................................................................................................13
Interior Electric Service..........................................................................................................................................14
All Interior Rooms ................................................................................................................................................. 15
Attic..........................................................................................................................................................................18
Page 3 of 20
Porter's Wisconsin Inspections, LLC
6938 Otter Creek Rd.
Avoca, WI 53506
Ph#: (608) 583-6024
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
DEFINITION OF TERMS
FUNCTIONAL - Performing its function and its condition is appropriate for its age and use.
MARGINAL - Performing some or all of its functions, but not as intended, and/or its condition is not
appropriate for its age and use.
NON-FUNCTIONAL - Not performing its function or its condition is not appropriate for its age or use.
Replacement or extensive repair will be required to make FUNCTIONAL.
Possible HAZARD - A potential or current safety hazard. Correction of condition is recommended.
COMMENTS - condition requiring further explanation. Does not necessarily represent an improper
condition or need for repair.
REPAIRS NEEDED - Currently functioning, but appearance and/or age indicates that some repair is
needed for optimum function.
Not Visible - Not visible/not inspected.
N/A - Not applicable/not inspected.
GENERAL INFORMATION
6/17/2010 821 Peterson Ct. Page 4 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
GENERAL CONDITIONS
001. Main Entry
Faces
South.
002. Structure Bi-level.
003. Estimated/Repo
rted Age
The age of the home is approximately 20 yrs.
004. Area Town.
005. Street Through; Paved.
006. Weather
Conditions
Mostly sunny.
006.5. Temperature 61 to 70 degrees.
007. Approximate
starting time
9:00.
008. Occupied/Not
Occupied
Not occupied.
010. Present During
Inspection
Buyer. Realtor part of time.
Roofs & Chimneys
Step # Component
Comment
30. Method of
Inspection
Walked the roof.
31. Roof Design Gable.
32. Type of roofing Composition shingles.
33. Low pitch Roof NA.
6/17/2010 821 Peterson Ct. Page 5 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
35. Roof conditions Marginal. Missing some grit. I would expect roof should last
another 5 years or so.
36. Flashings Functional. Cut shingle valleys.
38. Vents Functional. Roof Louvers; Soffit venting.
6/17/2010 821 Peterson Ct. Page 6 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
Grounds & Deck
Step # Component
Comment
1. Driveway Functional. Asphalt.
1a. Walks Repairs needed. Concrete. Cracked and settling at front
entrance. Trip hazard, should watch those unsure of foot if
not replacing or repairing this at front and along the walk.
Walk is also settled at front garage service door as well.
1b. Main steps Functional. Concrete.
1ba. Other steps Functional. Wood.
2. Grade/Slope Repairs needed. Grade poor under deck could cause water to
pool Slopes toward building; recommend new grade at rear.
Could possibly add some small ditching to drain water away
as well.
6/17/2010 821 Peterson Ct. Page 7 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
2a. Grade
Clearance at
Walls
Marginal. This picture also shows very marginal grade slope.
Siding is too close to the soil but limited options to repair
and not contribute more to reverse soil grade.
2b. Downspout
Drainage
Repair needed. Should extend downspout extension.
Diagram shows why.
2e. Basement
Windows
N/A.
6/17/2010 821 Peterson Ct. Page 8 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
3b. Deck Rear. Deck flashing is missing; this flashing is to prevent
water from decaying the sill and or wall. Should at least add
caulk under siding starter strip.
6. Electrical
Entrance and
fixtures
Repairs needed. Underground; Exterior electric meter. Loose
meter box.
Walls & Gutters
Step # Component
Comment
40. Foundation Functional. Concrete block.
45. Exterior Finish Functional. Vinyl.
50. Soffits/Fascia/
Trim
Functional. Aluminum/vinyl covered.
52. Guttering Metal. Gutters need cleaning
53. Exterior Lights Functional. Light fixtures.
54. Electric/Outlets Functional. Has operable GFI’s
55. Hose faucet Functional. Has 2 frost free type.
56. Doors Functional. Insulated doors; Steel. Front storm door binds at
bottom when closing. Little option to repair, need to just pull
door to fully close.
6/17/2010 821 Peterson Ct. Page 9 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
57. Windows Repairs needed. Failed window thermo seal at West.
Decayed trim, at front window. Trim could be replaced.
Garage
Step # Component
Comment
120. Garage Type: 2-car; Attached.
122. Roof Structure Functional. Trusses; plywood sheathing.
125. Foundation Functional. Concrete.
125b. Service door Functional.
126. Floor Functional. Concrete. Typical cracks noted.
127. Vehicle Doors Functional. Overhead; 1 door; metal insulated
128. Opener(s) 1 opener. Down force should be reduced
129. Interior walls Unfinished
130. Electrical Wiring lights & outlets. Outlet/switch cover missing Lacks
GFI outlets
6/17/2010 821 Peterson Ct. Page 10 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
Heating/Cooling
Step # Component
Comment
75. Manufacturer
(heating)
Warm air. Amana.
Diagram shows typical high efficiency furnace.
75.5. Thermostat Functional. Manual.
76. Age Marginal. Age is 19 years old. Typical expected life span
would be 15 to 20 years.
79. Cabinet Functional.
81a. BTU Rating Functional. 70K btu.
82. Fuel Supply Natural Gas. Natural Gas.
83. Burners/Elemen
ts
Functional.
84. Venting Functional. PVC power vent. This type of venting indicates
that the unit is a "high efficiency" appliance and an induced
fan is installed.
85. Heat
Exchanger
Not Visible.
86. Filter/Humidifi
er
Functional. Disposable filter.
87. Ductwork Functional. Metal.
88. Manufacturer
(cooling)
Carrier. 3 Ton. Recommend leveling condenser unit to
improve efficiency and operation
6/17/2010 821 Peterson Ct. Page 11 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
89. Cooling System Functional. Heat pump. This unit can only be operated in
the heating or cooling mode during the inspection. In most
cases, if one is operating properly, the other will also because
the same components are being operated.
Basement
Step # Component
Comment
01. Description Functional. Mostly finished.
01.5. Basement stairs Functional. Interior.
02. Basement
Floors
Functional. Concrete.
03. Bearing
Structure
Functional. Wood beams.
03a. First Floor
Design
Functional. 16" on center; 2"x8"; Plywood sub floor.
03b. Sill insulation Not Visible.
04. Walls Functional. Concrete Block.
05. Moisture
Evidence
Functional. Has beaver system
06. Floor Drains N/A.
6/17/2010 821 Peterson Ct. Page 12 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
07. Sump Pit/Pump Comment. Beaver drainage into sump crock. Sump pump
pumps water into city sewer.
08. Crawl Space N/A.
General Plumbing
Step # Component
Comment
50. Water & Sewer
source
City Water & Sewer.
60. Main Water
Service
Functional. Copper.
6/17/2010 821 Peterson Ct. Page 13 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
61. Main Shut-off
Valve
Functional. Utility room by meters.
62. Supply Piping Copper. All water is soft
63. Drainage
Piping
Functional. PVC/ABS plastic.
64. Clean-out Functional. Stack.
65. Fixture Venting Functional.
66. Laundry
Connections
Functional. Washer; Dryer; Toilet.
67. Water Softener Repairs needed. Out of salt. Should add resin
Water Heater
Step # Component
Comment
69. Age Functional. 12 - 15.
70. Manufacturer Rheem. Glass lined. I would expect another 10 years of life
due to being glass lined.
71. Fuel Supply Functional. Natural Gas.
72. Operations/Con
nections
Functional.
6/17/2010 821 Peterson Ct. Page 14 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
73. Venting Functional. PVC piping. This type of venting indicates that
the unit is a "high efficiency" appliance and an induced fan
is installed. Manufacturer specifications are required to
verify proper installation.
74. Relief Valve
Piping
Overflow pipe missing, should add 3/4 “ pipe.
Interior Electric Service
Step # Component
Comment
142. Manufacturer &
conditions
Functional. GE
143. Panel Location Functional. Basement;
6/17/2010 821 Peterson Ct. Page 15 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
145. Main
Disconnect &
Conductors
Functional. Aluminum main conductor; 200 amp.
148. Grounding 2 Ground rods
155. Branch Wiring
Conductors
Functional. Breakers; Copper.
160. Unfinished
wiring
Functional. Grounded Romex.
All Interior Rooms Note: All outlets appear to be ungrounded. The plastic romex except for one wire in the main panel are
all the grounded type. I recommend someone check the connections at the outlets and connect the
grounds if possible.
Step # Component
Comment
10. Kitchen N/A. S/E. Outlets ungrounded 3 prong type. Recommend
adding GFI's
20. Living Room S/W. Outlets ungrounded 3 prong type.
20a. Dining Room Functional.
20a. Hall Functional.
6/17/2010 821 Peterson Ct. Page 16 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
25. Family Room Repairs needed. Basement. Outlets ungrounded 3 prong
type. They really should have stayed 2 prongs or a ground
wire added.
Insulation void area from Infrared. Confirmed no moisture.
40. Bath Functional. Basement. Outlet should be GFI protected due
to the close proximity of water
40a. Bath main floor Repairs needed. East; Main level. Outlets ungrounded 3
prong type. Outlet should be GFI protected due to the close
proximity of water. Light switch not working correctly, 3
way.
6/17/2010 821 Peterson Ct. Page 17 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
50. Both Basement
Bedrooms
Repairs needed. N/W; Basement. Window is 56” from floor
and should not be over 44 inches from floor or need to add a
fixed step or ladder. Comments SAME for both bedrooms.
Should add permanent step below window in each bedroom.
Diagram shows proper egress.
6/17/2010 821 Peterson Ct. Page 18 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
50a. Master
Bedroom
Repairs needed. N/E; Main level. Water damaged window
sill to north window pictured below.
Outlets ungrounded 3 prong type.
50aa. Bedroom N/W; Main level. Window is also starting to decay. Should
clean & paint.
70. Stairway Functional. Smoke Detector Present.
Attic
Step # Component
Comment
20. Attic Accessed
at:
Functional. Bedroom.
21. Attic type &
number
Full attic.
22. Structure Functional. Trusses.
23. Decking Functional. Plywood.
6/17/2010 821 Peterson Ct. Page 19 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
24. Ventilation Bath vent fan vents out the roof of which is the preferred
method.
Missing some of the soffit vents, they are laying on attic
floor. It would be prudent to install them.
6/17/2010 821 Peterson Ct. Page 20 of 20
Pre-Purchase Inspection
Porter's Wisconsin Inspections, LLC
This is a confidential report prepared for the client only. Any Use by Unauthorized Persons Prohibited. For additional information on home maintenance please go to our links section on our website. porterwisconsin.com.
25. Insulation Marginally acceptable. Cellulose type insulation 6 to 8"
Today’s standard is 10” or more of cellulose. There appears
to be a missed area over the family room that should be
corrected.
26. Electrical
Conditions
Not Visible. Insulation covered and can not see wiring.