Table of Contents 1. Installation Sequence ·······················································································································1 2. Phone and Modem Options Setting (Standard 19.2Kbps Connection)··············································2 3. Installation of USB Modem Driver (USB Connection) ····································································8 4. Dial-up Setting·······························································································································11 5. SNMP Service Setting ···················································································································21 6. Firewall Setup································································································································23 7. PNMT Setup··································································································································25 8. Network Connections Setting on Windows Vista ···········································································30 9. Launching PNMT ··························································································································33
ROI-S06907
- 1 -
1. Installation Sequence
Only Administrator group privilege level users are authorized to configure the following settings,
(1) Dial-up Connection
(2) Ethernet Connection
Standard 19200bps Modem Setting
(Phone and Modem Options Setting)
USB Modem Setting
(Installation of USB Com Port Driver)
Network Element (NE) other than
PASOLINK NEO PASOLINK NEO ONLY
Step 2: Dial-up Connection Setting
Step 3: SNMP Service Setting
Step 5: PASOLINK Network Management Terminal (PNMT) Setup
Step 6: Launching PNMT
Step 1: Modem Setting
Step 4: Firewall Setup
Step 2:Network Connections Setting
Step 3: Launching PNMT
Step 1: PASOLINK Network Management Terminal (PNMT) Setup
ROI-S06907
- 2 -
2. Phone and Modem Options Setting (Standard 19.2Kbps Connection)
This section deals with the use of a Standard 19.2Kbps Modem Dial-up connection. (for non-PASOLINK-NEO network elements). If you wish to use a USB Modem Driver (for PASOLINK-NEO network elements, please refer to 3.”Installation of USB Com Port Driver”, p.8.
(1) Click Start | Settings | Control Panel.
(2) Change to classic mode
ROI-S06907
- 3 -
(3) Click the Phone and Modem Options icon in the Control Panel window to start configuring the modem.
(4) If Location Information window will appear, enter your country and area code and then click [OK].
ROI-S06907
- 4 -
(5) Verify the Location and Area Code.
(6) Select the Modem tab. Click [Add] to continue with adding the new modem for the PNMT.
ROI-S06907
- 5 -
(7) heck Don’t detect my modem ... and click [Next] to continue.
(8) Select Standard Modem Types from the list of Manufacturers and Standard 19200bps Modem from the Models. Click [Next] to continue.
ROI-S06907
- 6 -
(9) Select Selected ports and COM#, then click [Next] to continue.
(10) Click [Finish] to complete the new modem installation.
ROI-S06907
- 7 -
(11) Verify that Standard 19200 bps Modem and COM1 are displayed. Click [OK].
(12) Please proceed directly to section 4. Dial-up Setting.
ROI-S06907
- 8 -
3. Installation of USB Modem Driver (USB Connection)
This section describes the installation of a USB Modem Driver (for PASOLINK-NEO network elements) as the dial-up connection.
Connect the PNMT computer to the LCT Port of the NE with a standard USB cable.
(1) Click Locate and install driver software (recommended).
(2) If following window will appear, click Don’t search online.
ROI-S06907
- 9 -
(3) Click Browse my computer for driver software (advanced).
(4) Insert the USB driver CD-ROM in the computer’s disk drive and set Search for driver software in this location and click [Next].
ROI-S06907
- 10 -
(5) Click [Install] in the Installation pop-up.
(6) USB Modem Driver Installation starts.
(7) USB Com Modem Driver installation is complete.
ROI-S06907
- 11 -
4. Dial-up Setting
(1) Click Start | Control Panel and the Network and Sharing Center icon to start configuring the Dialup setting.
(2) The Network and Sharing Center window appears. Click Setup a connection or network in the Tasks area.
ROI-S06907
- 12 -
(3) The Set up a connection or network window appears. Select [Connect to a workplace] and click [Next].
(4) Click [Dial directly].
ROI-S06907
- 13 -
In case of connecting with RS232C, Click [Modem-Standard 19200bps Modem].
In case of connecting with USB, Click [Modem-USB Modem Driver].
ROI-S06907
- 14 -
(5) In the New Connection Wizard window, input connection name and Dial-up phone number field.
Check Don’t connect now... and click [Next].
In case of connecting with RS232C-Type [PNMT(RS232C)]
In case of connecting with USB-Type [PNMT(USB)]
ROI-S06907
- 15 -
(6) User & Password setting window appears. Click [Create].
(7) The connection window appears. Click [Close].
ROI-S06907
- 16 -
(8) The Network and Sharing Center window appears. Click [Manage network connections ] in the Connect Dial-up Connection window
Select Connection and Right Click , Appear context menu and select Connection’s properties.
ROI-S06907
- 17 -
(9) In the Properties Window click on the General tab. Click [Configure].
RS232C setting
USB setting
(10) In the Modem Configuration window, uncheck all four checkboxes.
RS232C setting
USB setting
ROI-S06907
- 17 -
(11) Retain the default setting on the Options tab and click the PPP Setting.
RS232C setting
USB setting
(12) In the PPP Setting window, uncheck all the boxes. Click [OK] to go back to the previous window. And click the Security tab.
ROI-S06907
- 18 -
(13) Retain the default setting on the Security tab and click the Networking tab.
RS232C setting
USB setting
(14) On the Networking tab, uncheck File and Printer ... and Client for Microsoft... and Internet Protocol Version 6(TCP/IPv6)
RS232C setting
USB setting
ROI-S06907
- 20 -
(15) Highlight Internet Protocol (TCP/IP) and then click [Properties].
(16) Verify that both Obtain an IP address automatically and Obtain DNS server address automatically are selected.
(17) Click [Advanced].
(18) In the Advanced TCP/IP Settings window, uncheck Use IP header compression for the PPP link. Click [OK].
ROI-S06907
- 21 -
5. SNMP Service Setting
NOTE
It is necessary to remove SNMP Service or to stop it if it has already been installed.
(1) Click on Programs on the control panel.
(2) Click on Turn Windows features on or off.
(3) The User Account Control window appears. Click [Continue].
ROI-S06907
- 23 -
6. Firewall Setup
(1) Go to Control Panel. Windows Security Center.
(2) Click Windows Firewall.
(3) Select Change Settings.
ROI-S06907
- 24 -
(4) Select Advanced tab.
(5) Remove check mark on PNMT(USB) and PNMT(RS232C).
NOTE
Configuring the firewall as above, a security warning icon will appear on the task tray. After terminating PNMTj, please check mark on PNMTj(USB) and PNMTj(RS232C).You will need to re-configure the firewall each time you startup PNMTj.
ROI-S06907
- 25 -
7. PNMT Setup
NOTE
If PNMT software has already been installed, please uninstall it before you install a new version.
(1) Insert the PNMT Installation CDROM. Open the CDROM folder and double-click
install.exe.
(2) The following window appears until loading is completed.
ROI-S06907
- 26 -
(3) Introduction window appears. Click [Next].
(4) Specify the directory in which the PNMT is to be installed. Click [Next].
Restore Default Folder: Click this button to choose the license key folder
Choose: Click this button to select another directory
NOTE
The default path is C:\PNMSj. It is not possible to include blank spaces as in “Program Files”. (C denotes the directory where the currently running OS is installed)
ROI-S06907
- 27 -
(5) Specify the License Key file if one is available. Click [Next].
Restore Default Folder: Click this button to revert to default path
Choose: Click this button to choose the license key file
NOTE
If no license key file is available, operation in trial mode is possible.
IMPORTANT: IMMEDIATE IMPORT OF LICENSE
You may use the PNMT on a trial basis for 30 days. After that the PNMT can ONLY be used IF the license has been imported (activated). To obtain the license please contact NEC.
ROI-S06907
- 30 -
8. Network Connections Setting on Windows Vista
This section describes the network setting for 5000S. If you don’t wish to connect to 5000S, please precede directly 9. Launching PNMT.
(1) Select Start Control Panel
(2) Select the Network and Sharing Connections from the Control Panel window.
ROI-S06907
- 31 -
(3) Select the Network Connections from the Network and Internet Connections window.
(4) The following Local Area Connection Properties window will appear as default.
Return to the General tab and select the Internet Protocol (TCP/IP), then click on the Properties button.
ROI-S06907
- 32 -
(5) The following Internet Protocol (TCP/IP) Properties window will appear. Select the Use the following IP Address instead of the Obtain an IP address automatically. Set the IP address, Subnet mask and Default gateway as follows:
Item Setting
IP Address 172.17.254.254
Subnet mask 255.255.255.252
Default gateway 172.17.254.253
DNS server address is not required.
ROI-S06907
- 33 -
9. Launching PNMT
(1) Right click on PNMT and then click “Run as Administrator” to start the application.
(2) If following window will appear, select [Unblock]
ROI-S06907
- 34 -
(3) Enter User name and Password, and Select the Connection Entry.
After installation of the PNMT, the initial password will be:-
User name: admin
Password: (There is no initial password. Just press Enter.
A password can then be set.)
Connection: In case of connection to 5000S select Ethernet and PNMT(LAN/Direct) entry.
Otherwise select Dialup and PNMT(RS232C)/PNMT(USB) entry.
ROI-S06907
- 35 -
(4) Click [Login].
(5) If following window will appear, select [Public Location].
After This Dialog Click [Close]