1 Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty Ltd reserves the right to change or modify the design, specificaons, soware, hardware, firmware or Apps at any me without prior wrien or oral noce. Images and funcons in this manual should be considered as indicave only and may differ from the actual Myzone touch screen or Apps
Transcript
Page 1: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

1

Installation, Configuration & User Manual

for

Myzone3 series 400 to 435

Air Conditioning Control Systems

Reece Pty Ltd reserves the right to change or modify the design, specifica�ons, so�ware, hardware, firmware or Apps at any �me without prior

wri�en or oral no�ce. Images and func�ons in this manual should be considered as indica�ve only and may differ from the actual Myzone touch

screen or Apps

Page 2: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

2

Section Description Page No.

1.0 Installation 8

1.1 Myzone Naked 400 — Wiring layout for up to 8 zones 8

1.2 Myzone Naked 400 —Wiring layout for up to 14 to zones 9

1.3 Myzone Naked 405 — Wiring layout for up to 8 zones 10

1.4 Myzone Naked 405 —Wiring layout for up to 14 to zones 11

1.5 Myzone Naked 410 — Wiring layout for up to 8 zones 12

1.6 Myzone Naked 410 —Wiring layout for up to 14 to zones 13

1.7 Myzone Naked 415 — Wiring layout for up to 8 zones 14

1.8 Myzone Naked 415 —Wiring layout for up to 14 zones 15

1.9 Myzone Nano 420 — Wiring layout for up to 8 zones 16

1.10 Myzone Nano 420 —Wiring layout for up to 14 zones 17

1.11 Myzone Nano 425 — Wiring layout for up to 8 zones 18

1.12 Myzone Nano 425 —Wiring layout for up to 14 zones 19

1.13 Myzone Nano 430 — Wiring layout for up to 8 zones 20

1.14 Myzone Nano 430 —Wiring layout for up to 14 zones 21

1.15 Myzone Nexus 435 — Wiring layout for up to 8 zones 22

1.16 Myzone Nexus 435 —Wiring layout for up to 14 zones 23

1.17 Stand alone VAV system for a typical 4 zone system 24

1.18 Optional equipment for wireless temperature controlled zones 25

1.19 Optional equipment for wired temperature sensors 26

1.20 Optional equipment for iSense temperature and occupancy controlled zones 27

1.21 Optional equipment for colour touch screen temperature controlled zones 28

Table of contents

Page 3: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

3

Section Description Page No.

1.0 Installation (Cont.)

1.22 Example of different types of temperature sensors and controllers on a single system 29

1.23 Optional equipment for running multiple systems from a single Myzone Nexus touch screen 30

1.24 Option equipment for wired WiFi control of system 31

1.25 Option equipment for wireless WiFi control of system 32

1.26 Myzone 415 to 435 — Optional equipment for iSave addition (up to 6 zones) 33

1.27 Myzone 415 to 435 —Optional equipment for iSave addition (7 to 12 zones) 34

1.28 Optional equipment for Ethernet Home Automation connection 35

1.29 Integrated Myzone A/C, Lights, Irrigation & Security 36

1.30 Myzone wiring connection to AC units 37

1.30.1 Myzone wiring connection to Actron units 38

1.30.2 Myzone wiring connection to Haier units 39

1.30.3 Myzone wiring connection to Hitachi units 40

1.30.4 Myzone wiring connection to Kaden units 41

1.30.5 Myzone wiring connection to Kelvinator units 42

1.30.6 Myzone wiring connection to LG units 43

1.30.7 Myzone wiring connection to Midea units 44

1.30.8 Myzone wiring connection to Rinnai units 45

1.30.9 Myzone wiring connection to Samsung units 46

1.30.10 Myzone wiring connection to Temperzone units 47

1.30.11 Myzone wiring connection to York units 48

1.31 Myzone wiring connection to Universal Control Module 49

Table of contents

Page 4: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

4

Section Description Page No.

1.0 Installation (Cont.)

1.31.1 Universal Control Module—Gas heating thermostat only 50

1.31.2 Universal Control Module—1 stage gas heating + 1 x fan speed 51

1.31.3 Universal Control Module—1 stage gas heating + 1 stage cooling + 1 x fan speed 52

1.31.4 Universal Control Module—2 stage gas heating + 1 stage cooling + 1 x fan speed 53

1.31.5 Universal Control Module—2 stage gas heating + 2 stage cooling + 1 x fan speed 54

1.31.6 Universal Control Module—1 stage reverse cycle heat pump + 1 x fan speed 55

1.31.7 Universal Control Module—1 stage reverse cycle heat pump + 3 x fan speed 56

1.31.8 Universal Control Module—1 stage reverse cycle heat pump + auxiliary heating + 1 x fan speed 57

1.31.9 Universal Control Module—2 stage reverse cycle heat pump + auxiliary heating + 1 x fan speed 58

1.32 General installation instructions 59

2.0 System initialisation 60

2.1 During initialisation 61

2.2 Change screen orientation & type of graphic style from Classic / Portrait 62

2.3 Change screen orientation & type of graphic style from Modern / Portrait 63

3.0 System Configuration 64

3.1 Configuration main menu 65

3.2 Zone setup 66-67

3.2.1 Sensor configuration 68

3.2.2 Pairing and configuring Myzone RF sensors 69

3.2.3 Sensor calibration 70

3.2.4 iSense controller configuration 71

Table of contents

Page 5: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

5

Section Description Page No.

System Configuration (Cont.)

3.3 AC unit configuration 72

3.3.1 Fan auto configuration 73

3.3.2 Fan auto zone area setup 74

3.3.3 Master / Slave setup 75

3.4 System options (Display, Taglines, Filter Maintenance, Locks, Non Standard Damper Motors) 76-77

3.5 WiFi bridge configuration 78

3.5.1 Manual IP configuration 79

3.5.2 WiFi connection 80

3.5.3 Smart phone and tablet configuration—System requirements 81

3.5.4 Smart phone and tablet configuration—Equipment required and Configuration 82

3.5.5 Smart phone and tablet configuration—Using you App 83

3.6 Home automation integration 84

3.7 Myzone Naked 400 remote (Zone only) — Configuration 85

3.8 Myzone Naked 410 remote— Configuration 86

4.0 User Manual 87

4.1 Myzone 400 & 405 home screen 87

4.2 Myzone 410—435 home screen 88

4.3 Myzone AC unit control 89

4.4 Zone control 90

4.5 Edit zone names and settings 91

4.6 Adjusting temperature controlled zones 92

Table of contents

Page 6: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

6

Table of contents

Section Description Page No.

User Manual (Cont.)

4.7 Zone airflow summary 93

4.8 Changing zone airflows 94

4.9 Favourites 95

4.10 Assigning and editing favourites 96

4.11 Schedules 97

4.12 Setting and editing a schedule 98

4.13 Setting the time 99

4.14 Changing the home screen colour 100

4.15 iSense controller 101

4.16 Myzone Naked 400 remote control (Zone only) 102

4.17 Myzone Naked 410 remote control 103

5.0 Further assistance 104

Page 7: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

7

This page has been inten�onally le� blank for your notes

Page 8: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

8

1.0 Installation

1.1 Myzone Naked 400 - Wiring layout for up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

8 Zone system with wireless remote control shown above

A maximum of 14 zones can be supported by one Myzone system. Any

touchscreen, temperature sensor or iSense controller can be added as an

optional extra

CZDA

CM

T2

4A

C

CM225

CM400FOB

Page 9: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

9

1.2 Myzone Naked 400 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with wireless

remote control shown above. Any

touchscreen, temperature sensor or

iSense controller can be added as an

optional extra

CMEXT

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

CMT24AC

CM400FOB

CM225

Page 10: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

10

1.3 Myzone Naked 405 - Wiring layout for up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

8 Zone system with WiFi control shown

above

A maximum of 14 zones can be supported by one

Myzone system. Any touchscreen, temperature sensor

or iSense controller can be added as an optional extra

CML5BK Wireless Bridge

Customers router or modem

CR (op)onal) Wireless Repeaters

Download the Myzone3 App to your smart phone or tablet

CM

T2

4A

C

CM225

Page 11: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

11

1.4 Myzone Naked 405 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with WiFi

control shown above. Any

touchscreen, temperature sensor or

iSense controller can be added as an

optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

CR (op)onal) Wireless Repeaters

Download the Myzone3 App to your smart phone or tablet

CM225

CMEXT

Page 12: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

12

1.5 Myzone Naked 410 - Wiring layout for up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

8 Zone system with wireless remote control shown above

A maximum of 14 zones can be supported by one Myzone system. Any

touchscreen, temperature sensor or iSense controller can be added as

an optional extra

CM410FOB

CM225

CMEXT

Page 13: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

13

1.6 Myzone Naked 410 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with wireless

remote control shown above. Any touchscreen, temperature sensor

or iSense controller can be added as an

optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

CM325#

Make sure you

have the correct

model for the

brand of AC unit.

CM410FOB

CM225

CMEXT

Page 14: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

14

1.7 Myzone Naked 415 - Wiring layout for up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

8 Zone system with WiFi control shown above

A maximum of 14 zones can be supported by one Myzone system.

Any touchscreen, temperature sensor or iSense controller can be

added as an optional extra

CML5BK Wireless Bridge

Customers router or modem

CR (op)onal) Wireless Repeaters

Download the Myzone3 App to your smart phone or tablet

CM225

CM325#

Page 15: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

15

1.8 Myzone Naked 415 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with WiFi

control shown above. Any

touchscreen, temperature sensor or

iSense controller can be added as an

optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

Make sure you

have the correct

model for the

brand of AC unit.

CR (op)onal) Wireless Repeaters

CML5BK Wireless Bridge

Customers router or modem

Download the Myzone3 App to your smart phone or tablet

CM225

CMEXT

CM325#

Page 16: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

16

1.9 Myzone Nano 420 - Wiring layout for up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

CMCTS

8 Zone system with one Nano touchscreen shown

above

A maximum of 14 zones can be supported by one Myzone system.

Any additional touchscreen, temperature sensor or iSense control-

ler can be added as an optional extra.

CM225

CMEXT

Page 17: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

17

1.10 Myzone Nano 420 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with one Nano

touch screen shown above. Any

touchscreen, temperature sensor or

iSense controller can be added as an

optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

Make sure you

have the correct

model for the

brand of AC unit.

CMCTS

CM225

CMEXT

CM325#

Page 18: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

18

1.11 Myzone Nano 425 - Wiring layout up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

8 Zone system with Nano touchscreen & WiFi control

shown above

A maximum of 14 zones can be supported by one Myzone system.

Any additional touchscreen, temperature sensor or iSense control-

ler can be added as an optional extra.

CR (op)onal) Wireless Repeaters

CML5BK Wireless Bridge

Customers router or modem

CMCTS

Download the Myzone3 App to your smart phone or tablet

CM225

CMEXT

Page 19: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

19

1.12 Myzone Nano 425 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with Nano

control & WiFi control shown

above. Any touchscreen, temperature

sensor or iSense controller can be

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

Make sure you

have the correct

model for the

brand of AC unit.

CR (op)onal) Wireless Repeaters

CML5BK Wireless Bridge

Customers router or modem

CMCTS

Download the Myzone3 App to your smart phone or tablet

CM225

CMEXT

CM325#

Page 20: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

20

1.13 Myzone Nexus 430 - Wiring layout up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

CMCTSL

8 Zone system with one Nexus touchscreen shown

above

A maximum of 14 zones can be supported by one Myzone system.

Any additional touchscreen, temperature sensor or iSense

controller can be added as an optional extra.

CM225

CM325#

Page 21: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

21

1.14 Myzone Nexus 430 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with one Nexus

touchscreen shown above. Any

touchscreen, temperature sensor or

iSense controller can be added as an

optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

Make sure you

have the correct

model for the

brand of AC unit.

CMCTSL

CM225

CMEXT

CM325#

Page 22: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

22

1.15 Myzone Nexus 435 - Wiring layout up to 8 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

CMT24AC

AC Unit

AC unit control cable.

See table for loca)on

of connec)on in AC

unit (1.30)

Make sure you have

the correct model

for the brand of AC

unit.

CMCTSL

8 Zone system with one Nexus touchscreen & WiFi

control shown above

A maximum of 14 zones can be supported by one Myzone system.

Any additional touchscreen, temperature sensor or iSense

controller can be added as an optional extra.

CR (op)onal) Wireless Repeaters

CML5BK Wireless Bridge

Customers router or modem

Download the Myzone3 App to your smart phone or tablet

CM225

CM325#

Page 23: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

23

1.16 Myzone Nexus 435 - Wiring layout for up to 14 zones

Zone 1

Zone 5

Zone 3

Zone 7

Zone 8

Zone 4

Zone 6

Zone 2

14 Zone system with one Nexus

touchscreen & WiFi control

shown above. Any touchscreen,

temperature sensor or iSense controller

can be added as an optional extra

CMT24AC

Zone 11

Zone 9

Zone 13

Zone 14

Zone 10

Zone 12

AC Unit

AC unit control

cable.

See table for

loca)on of

connec)on in AC

unit (1.30)

Make sure you

have the correct

model for the

make of AC unit.

CR (op)onal) Wireless Repeaters

CML5BK Wireless Bridge

Customers router or modem

CMCTSL

Download the Myzone App to your smart phone or tablet

CM225

CMEXT

CM325#

Page 24: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

24

1.17 Stand alone VAV systems - Wiring layout for typical 4 zone

system

Zone 1

Zone 3

Zone 4

Zone 2

4 Zone system shown above. (VAV4)

A maximum of 14 zones and 14 iSense controllers can be supported by one

Myzone system. For VAV1 to VAV3 no CNEM is required

CM

T2

4A

C

CMT24AC

CNEM

Network Extension Module

CDTS

CZCO iSense wired Zone Controllers with temperature and occupancy sensor (Max 12 per system)

CM225

Page 25: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

25

1.18 Optional equipment for wireless temperature controlled zones

CDTS Installed into the supply air duct off the fan coil unit. Must be installed on all zone temperature controlled systems

CRFS (op)onal) Wireless Temperature Sensors (Max 14 per system) CR (op)onal)

Wireless Repeaters To extend wireless range

Power supply, Zone motors and CMEXT, remote controls and touchscreens not shown for clarity

CM225

Page 26: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

26

1.19 Optional equipment for wired temperature sensors

CDTS Installed into the supply air duct off the fan coil unit. Must be installed on all zone temperature controlled systems

CS (op)onal) Wired Temperature Sensors (Max 14 per system)

CWSM (op)onal) Install Sensor Module to allow for Wired temperature sensors (CS)

CWSM

Wired Sensor Module

Power supply, Zone motors and CMEXT, remote controls and touchscreens not shown for clarity

CM225

Page 27: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

27

1.20 Optional equipment for iSense temperature and occupancy

controlled zones

CDTS Installed into the supply air duct off the fan coil unit. Must be installed on all zone temperature controlled systems

CZCO iSense(op)onal) Wired Zone Controllers with temperature and occupancy sensor (Max 12 per system)

CMT24A CNEM (op)onal) Install Network Extension Module to provide addi)onal network ports if required

Power supply, Zone motors and CMEXT not shown for clarity

CMCTS

CNEM

Network Extension Module

CM225

Page 28: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

28

1.21 Optional equipment for colour touch screen temperature

controlled zones

CDTS Installed into the supply air duct off the fan coil unit. Must be installed on all zone temperature controlled systems

CMT24A CNEM (op)onal) Install Network Extension Module to

provide addi)onal network ports if required

Power supply, Zone motors and CMEXT not shown for clarity

CMCTSL Nexus colour touch screen

CMCTS Nano colour touch screen

CNEM

Network Extension Module

CM225

Page 29: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

29

1.22 Example of different types of temperature sensors on a

single system

CDTS Installed into the supply air duct off the fan coil unit. Must be installed on all zone temperature controlled systems

CMCTSL Install

addi)onal colour touch

screens in zones

requiring temperature

control. (Max 12)

CS Wired Temperature Sensors (Max 12 per system)

CZCO iSense Wired Zone Controllers with temperature and occupancy sensor (Max 12 per system)

Connect Sensor module to any network port in the system (Myzone Net port

CMT24ACRFS Wireless Temperature Sensors (Max 14 per system) CNEM

Install Network Extension Module to provide addi)onal network ports if required

CR Wireless repeaters To extend wireless

range

Power supply, Zone motors and CMEXT not shown for clarity

CWSM Install Wired Sensor Module to allow for Wired temperature sensors (CS)

CWSM

Wired Sensor Module

CMCTS Nano colour touch screen

CNEM

Network Extension Module

CM225

Page 30: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

30

1.23 Optional equipment for running multiple systems from a

single Myzone screen

CMT24A

CISM (op)onal) Install Myzone system

mul)plexer to display up to 5 systems on a single

touch screen. A maximum of 3 x CMCTSL’s

can be connected to a CISM

Power supply, Zone motors and CMEXT not shown for clarity

CMCTSL Nexus colour touch screen will display

both systems 1 and system 2

CMCTS Nano colour

touch screen serving

System 2 only

CISM

System 1 System 2

Notes: 1. When using the

mul�plexer, you cannot use the in-built screen, temperature sensor, in any Nexus screens connected to the mul�plexer.

2. The CM225 plugged into the port labelled “CCPU 1” will be displayed first on the Nexus touch screen.

3. You can only use a Nexus touch screen on a CISM. Nano touch screen are not suitable for this purpose.

CM225 CM225

Page 31: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

31

1.24 Optional equipment for wired WiFi Control of system

CML5B Wired Bridge

Customers router or modem

CGB2C35 This special cable is specific for connec)ng the CPU and Wired

Bridge

Power supply, Zone motors and CMEXT not shown for clarity

Ethernet

Download the Myzone3 App to your smart phone or tablet.

CM225

Page 32: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

32

1.25 Optional equipment for wireless WiFi control of system

CML5B Wireless Bridge

Customers router or modem

CR (op)onal) Wireless Repeaters

Power supply, Zone motors and CMEXT not shown for clarity

Download the Myzone3 App to your smart phone or tablet.

CM225

Page 33: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

33

1.26 Myzone 415 to 435 - Optional equipment for iSave addition (up to 6 zones)

Note:

When the iSave option is used with an 8 zone system it is limited to a

maximum of 6 Zones

Return

Air Damper 1

Return

Air Damper 2

Outside Air

Air Damper 1

Outside Air

Air Damper 2

CDAK

Use Zone 8 port on CM225 for Outside Air dampers Use Zone 7 port on CM225 for Return Air dampers

Power supply, Zone motors and CMEXT not shown for clarity

CDAK

CM225

CM325#

Page 34: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

34

1.27 Myzone 415 to 435 - Optional equipment for iSave addition

Note:

When the iSave option is used with the CMEXT the Myzone system is lim-

ited to a maximum of 12 Zones

Return

Air Damper 1

Return

Air Damper 2

Outside Air

Air Damper 1

Outside Air

Air Damper 2

CDAK

Use Zone 14 port on CMEXT for Outside

Air dampers

Use Zone 13 port on CMEXT for Return

Air dampers

Power supply, Zone motors and CMEXT not shown for clarity

CDAK

CM225

CMEXT

CM325#

Page 35: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

35

1.28 Optional equipment for Ethernet Home Automation connection

CML5B

Home Automa)on System by

others

CGB2C35 This special cable is specific for

connec)ng the CM225 and Wired Bridge

Power supply, Zone motors and CMEXT not shown for clarity

Ethernet

Op�onal wireless communica�ons between

CML5B and CM225

CM225

Page 36: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

36

3 BuEon Wireless iLight switch with occupancy light intensity & AC temp sensor

1.29 Integrated Myzone A/C, Lights, Irrigation & Security

A maximum of 24 Irrigation stations, 14 AC zones, 128 lights / power

points / garage doors and 12 colour touch screens can be supported by one

Myzone system

Customers router or modem

CML5B Wireless Bridge

tablet

CR (op)onal) Wireless Repeaters

Lights (Max 128)

CMT24

AC Unit

Myzone AC control (Max 14 Zones)

CRFS (op)onal) Wireless Temperature Sensors

Wireless power points

Garage door

control

Wireless garden irriga)on

(Max 24 sta)ons)

(op)onal)

Wireless AC remote control

Google Home IFTTT

Smart phone

CM225

CM325#

Page 37: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

37

1.30 Myzone - Wiring connection to AC units

Unit Make Connection

MHI Take the Remote Controller wire from the fan

coil unit and connect it to the AC Unit Control

Cable on the CM225 / CM325MHI

Panasonic Take the A / B control wire from the fan coil

unit and connect it to the AC Unit Control

Cable on the CM225 / CM325P

Rinnai See detailed instructions on 1.30.8 page 45

Samsung* Take the F3 / F4 control wire from the fan coil

unit and connect it to the AC Unit Control

Cable on the CM225 / CM325S. This

connection requires the correct polarity. See

detailed instructions on 1.30.9 page 46

Temperzone See detailed instructions on 1.30.10 page 47

Toshiba Take the A / B control wire from the fan coil

unit and connect it to the AC Unit Control

Cable on the CM225 / CM325T

York* See detailed instructions on 1.30.11 page 48

Universal Control

Module

The universal control module covers units with

standard 24V control. See detailed instructions

on 2.31 to 2.31.9 pages 49-58

Unit Make Connection

Actron* See detailed instructions on 1.30.1 page 38

Daikin Take the P1 / P2 control wire from the fan coil

unit and connect it to the Myzone CM225 /

CM325D

Fujitsu* Do not connect the 12V wire to the Myzone

(Usually Red). Connect the black and white

wires from the fan coil unit to Myzone CM225 /

CM325F

Haier See detailed instructions on 1.30.2 page 40

Hitachi Take the A / B control wire from the fan coil

unit and connect it to the Myzone CM225 /

CM325H

See detailed instructions on 1.30.3 page 46

Kaden See detailed instructions on 1.30.4 page 41

Kelvinator See detailed instructions on 1.30.5 page 42

LG See detailed instructions on 1.30.6 page 43

Midea See detailed instructions on 1.30.7 page 44

Mitsubishi Electric Take the Remote Controller (A / B) control

wire from the fan coil unit and connect it to the

AC Unit Control Cable on the CM225 / * Certain models only. Check with Reece for compatibility prior to ordering

Page 38: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

38

1.30.1 Myzone - Wiring connection to Actron units Unit Make Connection

Actron ( Ultra Slim low profile series only)

Indoor Model / Outdoor model

LRE-071AS / URC-071AS ( 7kw )

LRE-100AS / URC-100AS ( 10kw )

LRE-130AS / URC-140AS (14kw )

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325A to the

X / Y in the fan coil unit. (This cable and connector is supplied by Actron). Polarity is

critical see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325A

Correct polarity

Y X

Page 39: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

39

1.30.2 Myzone - Wiring connection to Haier units Unit Make Connection

Haier

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325HI to the

A / B terminals on the Haier Interface board YCJ-A002. Connect the interconnecting

cable supplied by Haier to CN24 in the fan coil unit of the Haier Interface board YCJ-A002.

Set the dipswitches as shown below. Polarity is critical.

Fig (N) - Myzone CM225 / CM325HI

Fig (L) Haier Interface board

Model: YCJ-A002 (Fisher & Paykel part

no. 51102 ) Shielded, 2 core, twisted pair control cable

(not supplied)

B A

Correct polarity

CN24

Fig (M) Haier FCU board

Interconnecting cable

supplied by Haier.

Requires the plug to

be cut off to connect

to the Haier interface

Dipswitch all=OFF 1 = OFF

A

B

Page 40: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

40

1.30.3 Myzone - Wiring connection to Hitachi units Unit Make Connection

Hitachi

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325H to the

A / B terminals and earth in the in the fan coil unit. (This cable is supplied by the installer).

Polarity is not critical see Fig (H) for correct connection.

Fig (H) - Hitachi indoor fan coil unit terminals

L1

Indoor Unit

L2 N

Mp

A B 1 2

To Myzone CM325

Shielded Twisted Pair cable

(Supplied by the Installer)

0.75mm2. This cable does

not need any polarity. Do not

apply voltage to this cable.

Page 41: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

41

1.30.4 Myzone - Wiring connection to Kaden units Unit Make Connection

Kaden (Reece)

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325KAD to

the X / Y in the fan coil unit. (This cable and connector is supplied by Kaden). Polarity is

critical see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325KAD

Correct polarity

Y X

Page 42: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

42

1.30.5 Myzone - Wiring connection to Kelvinator units Unit Make Connection

Kelvinator

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325KEL to the

X / Y in the fan coil unit. (This cable and connector is supplied by Kelvinator). Polarity is

critical see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325KEL

Correct polarity

Y X

Page 43: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

43

1.30.6 Myzone - Wiring connection to LG units Unit Make Connection

LG

LG condensing unit must be supplied with an

optional PI485 Gateway (M) board in the

condensing unit. LG dipswitch settings are as

follows:

Dip switches 1 and 4 ON

All others are OFF

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325L to the

PI485 Gateway (M) board in the condensing unit. (This cable is supplied by the installer).

Polarity is critical see Fig (C) & (D) for correct connection.

Fig (C) - LG PI485 Gateway (M) board in condensing

unit

Shielded, 2 core,

twisted pair control

cable (not supplied)

A

B

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325LG

Correct polarity

B A

Page 44: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

44

1.30.7 Myzone - Wiring connection to Midea units Unit Make Connection

Midea

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325MID to the

X / Y in the fan coil unit. (This cable and connector is supplied by Midea). Polarity is critical

see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / C32MID

Correct polarity

Y X

Page 45: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

45

1.30.8 Myzone - Wiring connection to Rinnai units Unit Make Connection

Rinnai

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325R to the

X / Y in the fan coil unit. (This cable and connector is supplied by Rinnai). Polarity is

critical see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325R

Correct polarity

Y X

Page 46: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

46

1.30.9 Myzone - Wiring connection to Samsung units Unit Make Connection

Samsung

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325S to the

F3 / F4 in the fan coil unit. (This cable is supplied by the installer). Polarity is critical see

Fig (F) & (G) below for correct connection.

Fig (F) - Samsung indoor fan coil unit terminals

Shielded, 2 core,

twisted pair control

cable (not supplied)

F4

F3

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (G) - Myzone CM225 / CM325S

Correct polarity

F4 F3

Page 47: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

47

1.30.10 Myzone - Wiring connection to Temperzone units Unit Make Connection

Temperzone 1. Connect a shielded, 2 core, twisted pair control cable from the CM225 to the UC8 board in the condensing unit.

(This cable is supplied by the installer). Polarity is critical see Fig A & B for correct connection.

2. Ensure the dip switches in the condensing unit are set correctly for the installed compressor type (digital / fixed

speed) and fan speed control. Refer to the Temperzone service manual.

Fig (A) - Temperzone UC8 outdoor board

Shielded, 2 core, twisted pair

control cable (not supplied)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (B) - Myzone CM225 / CM325TZ

Correct polarity

B A

Page 48: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

48

1.30.11 Myzone - Wiring connection to York units Unit Make Connection

York

1. Connect a shielded, 2 core, twisted pair control cable from the CM225 / CM325Y to the

X / Y in the fan coil unit. (This cable and connector is supplied by York). Polarity is critical

see Fig (i) (J) & (K) below, for correct connection.

X Y E +12V

CN40 Connector Pin out

Fig (i) - Indoor fan coil unit

terminals X Y

Fig (J)

Shielded, 2 core,

twisted pair control

cable (not supplied)

Fig (K) - Myzone CM225 / CM325Y

Correct polarity

Y X

Page 49: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

49

1.31 Myzone - Wiring connection to Universal Control Module Unit Make Connection

Units that accept 24V control signals:

Gas Hea)ng Op)ons

• Gas Hea�ng thermostat only

• 1 Stage Gas Heat + 1 x Fan Speed

• 1 Stage Gas Heat + 1 Stage Cool + 1 x Fan Speed

• 2 Stage Gas Heat + 1 Stage Cool + 1 x Fan Speed

• 2 Stage Gas Heat + 2 Stage Cool + 1 x Fan Speed

Reverse Cycle Op)ons

• 1 Stage R/C + 1 x Fan Speed

• 1 Stage R/C + 3 x Fan Speed

• 1 Stage R/C + Aux Hea�ng + 1 x Fan Speed

• 2 Stage R/C + Aux Hea�ng + 1 x Fan Speed

1. Connect cables as shown on the wiring diagram for the respective option. (24V maximum)

2. Configure the correct system type on the touch screen.

3. Configure the Run on timer, anti-cycle timer, 2nd stage offset, 2nd stage delay and fan

control on the touch screen, as applicable

4. Test for correct operation.

Page 50: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

50

1.31.1 Myzone - Wiring connection to Universal Control Module

Gas heating thermostat only

CO

M

He

at

EQUIPMENT

24V Maximum

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

Gas Heating thermostat only

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 51: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

51

1.31.2 Myzone - Wiring connection to Universal Control Module

1 Stage Gas Heating + 1 x Fan Speed

CO

M

He

at

EQUIPMENT

CO

M

Fa

n

24V Maximum

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

1 Stage Gas Heat + 1 x Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time

as required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 52: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

52

1.31.3 Myzone - Wiring connection to Universal Control Module

1 Stage Gas Heating + 1 Stage Cooling

+ 1 x Fan Speed

CO

M

He

at

EQUIPMENT

CO

M

Fa

n

24V Maximum C

oo

l

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

1 Stage Gas Heat + 1 Stage Cool + 1 x Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time

as required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 53: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

53

1.31.4 Myzone - Wiring connection to Universal Control Module

2 Stage Gas Heating + 1 Stage Cooling

+ 1 x Fan Speed

CO

M

He

at 1

EQUIPMENT

CO

M

Fa

n

24V Maximum C

oo

l

He

at 2

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

2 Stage Gas Heat + 1 Stage Cool + 1 x Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time

as required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 54: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

54

1.31.5 Myzone - Wiring connection to Universal Control Module

2 Stage Gas Heating + 2 Stage Cooling

+ 1 x Fan Speed

CO

M

He

at 1

EQUIPMENT

CO

M

Fa

n

24V Maximum C

oo

l 1

He

at 2

Co

ol 2

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

2 Stage Gas Heat + 2 Stage Cool + 1 x Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time

as required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 55: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

55

1.31.6 Myzone - Wiring connection to Universal Control Module

1 Stage Reverse Cycle Heat Pump + 1 x Fan Speed

CO

M

R/V

alv

e

EQUIPMENT

CO

M

Fa

n

24V Maximum C

om

p

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

1 Stage R/C + 1 Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time as

required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 56: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

56

1.31.7 Myzone - Wiring connection to Universal Control Module

1 Stage Reverse Cycle Heat Pump + 3 x Fan Speed

CO

M

R/V

alv

e

EQUIPMENT

CO

M

Fa

n Lo

w

24V Maximum C

om

p

Field wiring by

installer

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

1 Stage R/C + 3 Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time as

required . Setup Fan control

Fa

n M

ed

Fa

n H

i

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 57: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

57

1.31.8 Myzone - Wiring connection to Universal Control Module

1 Stage Reverse Cycle Heat Pump +

Aux Heating + 1 x Fan Speed

CO

M

R/V

alv

e

EQUIPMENT

CO

M

Fa

n

24V Maximum C

om

p

Field wiring by

installer

Au

x H

ea

t

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

1 Stage R/C + Aux Heating + 1 x Fan Speed

Press Next > Next. Adjust Minimum run time and Anti-cycle time

as required . Setup Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 58: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

58

1.31.9 Myzone - Wiring connection to Universal Control Module

2 Stage Reverse Cycle Heat Pump +

Aux Heating + 1 x Fan Speed

CO

M

R/V

alv

e

EQUIPMENT

CO

M

Fa

n

24V Maximum C

om

p 1

Field wiring by

installer

Au

x H

ea

t

Co

mp

2

Configure required functionality via touch screen as follows:

Go to Config > AC Unit Setup > Next > press edit pencil > Select :

2 Stage R/C + Aux Heating + 1 x Fan Speed. Press Next > Next.

Adjust Minimum run time and Anti-cycle time as required . Setup

Fan control

Universal Control

Module

CUCM

CO

M

A

B

C

D

E

CFC1

CM

22

5

Page 59: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

59

1.32 General installation instructions

1. The CM225, CM325 and CMEXT can be installed close to the indoor fan coil unit.

2. If any wireless sensor (CRFS) or wireless bridge (CML5B) is not within the range of the CM225 then additional repeaters (CR) should be added to help relay the signal from the field device to the CM225 and the CML5B.

3. Do not run the network cables alongside 240 Volt wiring.

4. When installing network cables down wall cavities or chasing network cables into walls, tape up and protect the RJ45 connector to avoid damage to the connectors. Installation damage to cables is not covered under warranty.

5. Always install zones in consecutive ports starting at Zone 1. The CM225 and CMEXT are marked with the zone port numbers.

6. Do not directly hardwire the CT24V into the AC unit’s power supply. This may void the warranty as it will require an electrician in the event that a repair of the Myzone power supply is required.

7. Connect Zone Damper Actuators (CZDA) to the zone ports using the RJ11 cables as shown.

8. Connect the Colour Touch Screens (CMCTS) to the Myzone Net ports using the RJ45 cables. If you are connecting more than 3 components requiring Myzone Net ports to the system you will need to connect a Network Extension Module Kit (CNEMK) to one of the Myzone Net ports on the CM225 using a short RJ45 cable.

9. If any zone is temperature controlled, connect an in Duct Temperature Sensor (CDTS) to the CDTS port. Install the sensor into the supply air duct upstream of all dampers. Secure the sensor in place by using reinforced aluminium tape.

10. When installing temperature controlled zones ensure the CMCTS or sensor for the associated zone is installed in a location that is representative of the temperature in the room / zone . The sensor should be installed at approximately 1600mm above the floor and should not be subject to draughts, direct sunlight or heat from equipment such as computers, TV screens etc. The supply air outlets to this room must not blow conditioned air directly onto the sensors or touch screens.

11. Connect the AC unit control cable to the CM225 / CM325. See table 1.30 for details. (This control cable must be a shielded cable and is not supplied by Reece.)

12. The building must be fitted with a compatible WiFi modem. Contact Reece for a list of approved and recommended modems.

13. If connecting the Myzone system to a Home Automation system use the Ethernet connection on the bridge.

14. Only connect the power supply to the CT24VAC port after all components have been connected.

15. Any existing or new air conditioning units that require modification or additional boards to facilitate the correct operation of the Myzone system, is the responsibility of the installing contractor.

Page 60: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

60

2.0 System initialisation

All new or modified systems must be initialised prior to system configuration.

To initialise the system press the reset button on any colour touch screen. The

time to initialise the system will vary depending on the number of motors

connected.

The system will also initialise when power is restored after a power failure.

Progress bar will scroll while system ini�alises and tests all zone dampers

Using a pen, press the bu�on on the underside or side of the screen.

Myzone 325

Page 61: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

61

2.1 During initialisation

Progress bar

Current system configura�on

seEngs System type

Components detected and

so�ware versions

This screen will be displayed whenever the

system is reset or when power is restored

after a power failure. None of the previous

settings or parameters are lost.

This image is an example only.

Your screen may display differently

depending on the system type,

what options are selected and the

configuration settings entered by

your installing contractor.

MYZONE 425

CMCTS V2.21

CM225 V3.0

CZCO V1.0

CML5B V1.3

ID: 000000215

14 Zones

1 Constant

AC Control (Zones)

AC Temp displayed

Set Points unlocked

iSave disabled

Fan Auto enabled

Auto Off disabled

Filter Clean (6M)

Min Airflow locked

Some components and seEngs must be configured before

they can be displayed

Page 62: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

62

2.2 Changing the orientation and type of graphic

Classic / Portrait

Press

“SeEngs”

This image is an example only.

Your screen may display differently

depending on the system type,

what options are selected and the

configuration settings entered by

your installing contractor.

Landscape

Press Modern if you want to

change to “Modern” style of

graphics.

Press Landscape if you want

to remain in “Classic" style

but change to landscape

format

Page 63: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

63

2.3 Changing the orientation and type of graphic

Modern / Portrait

Press

“SeEngs”

This image is an example only.

Your screen may display differently

depending on the system type,

what options are selected and the

configuration settings entered by

your installing contractor.

Screen Configuration

Press

“Screen”

Beep is on

Landscape

Unhide Retic

Classic Display

Hide Lighting

Press Landscape if you want

to stay in “Modern" style but

change to landscape format

Press Classic Display if you

want to change to “Classic”

style of graphics.

Page 64: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

64

3.0 System configuration

WARNING ! Only qualified Myzone installers should configure the Myzone System. Incorrect configuration could result in damage to

your air conditioning unit and system.

To configure your system click on the System Config icon on the home page.

Enter the system password “wamfud” and press the enter button. The enter button must always be touched to

save changes.

You will now be in the System Configuration area.

Page 65: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

65

3.1 Configuration main menu

Touch here to edit the number of zones installed.

Touch here to edit the number of variable electronic constant zones required.

Touch here to change the system password

Touch here to list the devices and so�ware versions detected by this system

Touch here if you need to manually configure the IP address of the WiFi Bridge.

Touch here to go back to the Home screen

Myzone

Inventive . Intelligent . Intuitive

AC Unit Control

Myzone

Inventive . Intelligent

. Intuitive

No. of Zones 4

No. of Constants 1

Zone Setup

AC Unit Setup

Pair wireless device

iSave

Options

WiFi Bridge Config

Change Password *******

Myzone Device List

Touch here to enable iSave icons. iSave components must be installed and electronic hardware set up accordingly

Touch here to set up AC Unit Configura�on (see 3.3).

Touch here to set up and configure each zone (see 3.2).

Touch here to pair wireless devices

Touch here to set up Op�ons

Note:

Information on the

configuration screen

may vary depending

which devices are

connected to the

system and which

model of Myzone you

have

Page 66: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

66

3.2 Zone set up

Indicates this zone is fi�ed with a

wireless sensor. Touch here to

change.

Myzone

Inventive . Intelligent . Intuitive

Myzone

Inventive . Intelligent

. Intuitive

Kitchen Wireless

Const 1 Passage

Family Touch

Master Bed Wired

Jon Bed Opn/Clsd

Study iSense

Zone Setup

Indicates this zone is designated to

be the first electronic constant zone.

Indicates this zone is fi�ed with a wired

sensor. Touch here to change.

Indicates this zone temperature is

controlled via the sensor in a touch

screen. Press here to change.

If the zone has been named its name

will show here

Touch here to go to the home

screen

Indicates this zone has been set up for

Open / Close control only

Indicates this zone is set up for temper-

ature control via an iSense controller

Down Up

Page 67: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

67

3.2 Zone set up (cont)

Press here to view or make changes

to the wireless sensor status and

configura�on

Indicates this zone has been configured

to be climate controlled via a Wireless

Sensor

The configura�on of this zone can be

changed by simply selec�ng the

appropriate bu�on. Please note the

correct hardware must be fi�ed for the

zone to work correctly

Myzone

Inventive . Intelligent . Intuitive

Myzone

Inventive . Intelligent

. Intuitive

Kitchen

Manual Control

Constant

Open / Closed

Climate Control

Wireless Sensor

This Touch Screen

Wired Sensor

iSense Controller

Other Touch Screen

Page 68: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

68

3.2.1 Sensor configuration

Hold down the “Pairing Bu�on” on the Myzone

wireless device. (see 3.2.2).

Then press here to pair the device to your Myzone

system

Displays the Radio frequency channel the system has been

configured to. This channel can be changed if RF interference is being

experienced.

If the channel is changed all wireless devices need to be paired

Indicates the status of the ba�ery in the sensor in this zone

Touch here to go back and save any

changes.

Myzone

Inventive . Intelligent . Intuitive

AC Unit Control

Myzone

Inventive . Intelligent

. Intuitive

Sensor battery status : Good

Change Rf Channel 1

Pair wireless device

Kitchen

Signal strength : 100%

Calibrate Sensor - 0.2 C

Indicates the status of the wireless signal strength from the sensor in

this zone. It can take up to 10 minutes of normal opera�on to get

an accurate reading. To speed up the process press the Off / Auto

bu�on on the sensor 5 �mes.

Press here to adjust the calibra�on of this sensor (See 3.2.3)

Press here to change the Rf Channel

Page 69: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

69

3.2.2 Pairing and configuring Myzone RF Sensors

Set the zone selector switch to the correct

zone number

Remove front cover from sensor

Press and hold Pairing bu�on on the

wireless device . At the same �me press

the Pairing Bu�on on the touch screen

(see 3.2.1) and wait un�l the update is

complete

Pair

Note:

To pair other devices such as a Myzone

bridge or repeater simply press the

pairing buEon on the device and at the

same )me press the paring buEon on the

touch screen and wait for the update to

complete.

Page 70: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

70

3.2.3 Sensor Calibration

Touch here to adjust the calibra�on up by +0.1 deg. C

Myzone

Inventive . Intelligent . Intuitive

AC Unit Control

Myzone

Inventive . Intelligent

. Intuitive

Touch here to adjust the calibra�on down by -0.1 deg. C

Total calibra�on offset from manufactured seEng

Touch here to go back and save the

changes.

Kitchen

Calibrate sensor (22.2)

Down Up -0.2

Re-calibrated temperature for this zone

Note:

Re-calibra)on of the

temperature sensor in the

touch screens can only be done

from the touch screen you want

to re-calibrate.

Current reading with calibra�on offset included

Page 71: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

71

3.2.4 iSense controller configuration

Press and hold the “Airflow” bu�on to

configure the controller. Here you can

configure the correct Zone to control and

you can calibrate the sensor if required

Press and hold the “iSense” bu�on to enter

the Occupancy Strategy configura�on

menu. Follow the prompts to select the

most appropriate strategy for your room or

use the Custom Setup op�on to design your

own strategy

Indicates the iSense has been

ac�vated on this controller.

Note:

When iSense has been ac�vated

movement is required in the range of the

occupancy sensor to keep the zone

opera�ng. The use of the iSense feature in

bedrooms, when the occupants are asleep,

is not recommended.

System reset bu�on under

here

Page 72: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

72

3.3 AC unit configuration

Touch here to go back and save the

changes.

Select method of controlling the AC unit.

• R/Air will control using the unit’s return

air sensor.

• Master will control the AC unit from the

colour touch screen or zone sensor that

has been selected as the Master.

• Zones will automa�cally control the AC

unit from the temperature controlled

zones (high select).

Touch here to go to the home

screen.

Myzone

Inventive . Intelligent . Intuitive

Myzone

AC Unit Control

Myzone

Inventive . Intelligent

. Intuitive

AC Unit Controlling Sensor

AC Unit Setup

R/Air Master Zones

Auto mode dead band Dead band

Indicates the current dead band required

to automa�cally switch from Cooling to

Hea�ng. This dead band +/- 1.75oC from

the controlling sensor’s setpoint.

Touch here to adjust the deadband

Fan Auto Fan will adjust speed automatically depending on the position of the zone dampers

Unit Auto Off Unit will switch off automatically if all the zones are Closed

Touch here to enable / disable this

feature

Touch here to enable / disable this

feature

To configure Fan Auto see (3.3.1)

1.75 deg C

Page 73: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

73

3.3.1 Fan auto configuration

Touch here to enable Fan Auto control and

to proceed with Fan Auto set up

Touch here to set the AC Unit capacity for this

system. The capacity selec�on will provide an

approximate airflow capacity for the AC Unit.

Myzone

Inventive . Intelligent

. Intuitive

Inventive . Intelligent

. Intuitive

Myzone

Unit Capacity [kW] 14

Fan Airflow [l/s] 1020

Touch here to configure the zone areas (3.3.2)

Fan Auto Config

Capacities

Enable Fan Auto Control Auto Fan

Touch here to fine tune the airflow capacity. You

can set the exact airflow in litres per second. This is

available from the AC Unit manufacturer

2– Speed Fan

3– Speed Fan

Variable Speed Fan

Select Fan Type Select the correct fan speed type for the system installed. Refer to AC Unit

Manufacturer manual

Only available on certain AC unit makes

Page 74: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

74

3.3.2 Fan auto zone area setup

Touch here to set the kitchen area in

square meters

Myzone

Inventive . Intelligent

. Intuitive

Inventive . Intelligent

. Intuitive

Myzone

Living 33

Touch here to go to the next 3 zones

Fan Auto Config

Zone 2 Area (sqm)

Zone 1 Area (sqm)

Kitchen 10

Current area set for Zone 3

Zone name

Zone 3 Area (sqm)

Master Bed 21

Page 75: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

75

3.3.3 Master Slave Setup

Important Notes:

This is an Advanced seEng and should

only be a�empted by suitably qualified

Myzone technicians.

These seEng will only work with certain

makes and models of AC units. Contact

Reece to check if your system is suitable.

The AC system controls may require

addi�onal PCML5Bs, master / slave

adjustments or controller addressing for

these func�ons to operate.

Reece does not accept responsibility if

these seEng do not work correctly on

your par�cular system

Myzone

Inventive . Intelligent

. Intuitive

AC Unit Setup

Master / Slave Settings

Unit Info

Panasonic System can be turned On and Off via

the Myzone controller and another

non Myzone controller connected to

the Panasonic unit

Fault History

Myzone Other

On/Off

Mode

Fan

Setpoint

Touch here to go back and save the

changes.

Indicates a Panasonic AC unit module is

connected to this system

Touch here to view the fault

history for this AC unit.

System On/Off control

System mode control

System fan speed control

System setpoint adjustment

System mode can be changed by the

Myzone controller and another non

Myzone controller connected to the

Panasonic unit

System fan speed can only be

controlled by the Myzone controller

System setpoint can only be

controlled by a non Myzone

controller connected to the

Panasonic unit

Page 76: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

76

3.4 System Options (Display, Taglines & Filter Maintenance)

Select either Full System or Zone Only

Touch here to change line 1 of the tag line

Touch here to go back to the previous configura�on page

Select if you want the AC units controlling temperature to

be displayed

AC Unit Control

Myzone

Inventive . Intelligent . Intuitive

Myzone

Inventive . Intelligent

. Intuitive

Note:

Information on the

configuration screen

may vary depending

which devices are

connected to the

system and which

model of Myzone you

have

System Options

Display

Full System

Zone Only

Controlling Temperature

Tag Lines Myzone

Inven�ve . Intelligent

. Intui�ve

Filter Maintenance

Reminder Frequency 3 months

Touch here to change line 2 of the tag line

Touch here to change the filter clean reminder

frequency

Touch here to go back to the next page of op�ons

Page 77: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

77

3.4 System Options (Locks & Non Standard Damper Motors)

Touch to lock the AC Unit. You will need

to enter a PIN number and then the

number of days you want the system to

operate for, un�l it is automa�cally

locked off. Do not forget your PIN.

Service charges will apply for a

technician to a�end site to unlock your

system.

Touch here to set limits for set point adjustment

and to lock this seEng

Touch here to go back to the previous configura�on page

AC Unit Control

Myzone

Inventive . Intelligent . Intuitive

Myzone

Inventive . Intelligent

. Intuitive

Note:

Information on the

configuration screen

may vary depending

which devices are

connected to the

system and which

model of Myzone you

have

System Options

Locks

Temperature Adjustment

Airflow Adjustment

System Lock Out

Touch here to lock airflow adjustment. You can lock

minimum airflow only or both minimum and

maximum air flow adjustments

Damper Control Type

Timing Dampers

Select here for non standard dampers

such as Belimo.

You will need to type in the drive �me

in seconds from fully closed to fully

open.

Please note this will change the �ming

for all motors in the system so you

cannot have a mix of different motors

on the same system when using this

feature.

The damper fault detec�on is ignored

when this mode is used.

Page 78: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

78

3.5 Wifi bridge configuration

Myzone

Inventive . Intelligent . Intuitive

AC Unit Control

Myzone

Inventive . Intelligent

. Intuitive

ID: 123123123

WiFi Bridge Config

IP: 192.118.27.69

MAC: 00:04:A5:G9:32:39

Displays the Myzone system iden�fica�on

number

Displays the Bridge IP address allocated by

the DHCP

Displays Myzone Ethernet controller MAC

address

Touch here to go to the home

screen.

Touch here to go back and save the

changes. Touch here to go to the manual WiFi

configura�on

Page 79: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

79

3.5.1 Manual IP Configuration

Touch here to go back without saving the

changes.

Select either Auto or Manual Configura�on.

If manual is selected you will need to know

the IP, Subnet Mask, Default Gateway,

Primary DNS Server and Secondary DNS

Server addresses if applicable. If you require

manual configura�on please contact your IT

specialist to assist you.

Touch here to go to the home

screen.

Touch here to apply the changes to the

configura�on

Myzone

Inventive . Intelligent . Intuitive

Myzone

Inventive . Intelligent

. Intuitive

WiFi Configuration

IP Address

Manual Configuration

Auto Configuration

IP Address

0 0 0 0

0 0 0 0

0 0 0 0

0 0 0 0

0 0 0 0

Subnet Mask

Default Gateway

Primary DNS Server

Secondary DNS Server

Apply

Page 80: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

80

3.5.2 WiFi connection

A green symbol indicates the Myzone

system is now connected to WiFi and

ready to use

A grey symbol indicates the

Bridge is connected to the

Myzone system but is not

connected to the local

computer network

Myzone

Inventive . Intelligent

. Intuitive

Page 81: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

81

3.5.3 Smart Phone or Tablet configuration - System

Requirements

Smartphone or Tablet

• You will need a smartphone or tablet. The following

platforms are supported: Apple & Android.

System Requirements

iOS SOFTWARE REQUIREMENTS

• Compatible with iPhone, iPod touch, and iPad. iOS 6.0 and higher.

ANDROID SOFTWARE REQUIREMENTS

• Requires Android: 2.1 and higher.

WiFi modem or network switch

• You will also need a compatible WiFi modem or network

switch with a spare RJ 45 access port. Some WiFi

modems, firewalls and security settings are not

compatible with the Myzone bridge and will need to be

changed or replaced to enable the Myzone3 app to run.

Download the Myzone3 App

• You will need an account with the manufacturer of your

phone to enable you to down load Apps from their

respective store.

• Apple—Apple App Store

• Android—Google Play Store

• Login to the respective store.

• To search for the Myzone App3 type “Myzone Controller”

into the stores search menu.

• Select Myzone Controller and download the Myzone3

App.

Page 82: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

82

3.5.4 Smart Phone or Tablet - Equipment Required and

Configuration

Equipment

• See 3.53 For details of equipment required and wiring

diagram.

Configuration

• Power up the WiFi Bridge

• Press the System Config button on the

touchscreen

• Enter the system password “wamfud”

Pair the wireless bridge to the Myzone system

• Press and hold the blue button on the side of the Bridge. At the

same time press the “Pair Wireless Device” button on the

touchscreen

• Wait a few seconds. Press the home

button on the touch screen.

• The grey WiFi symbol should appear at the bo�om of

the home screen.

• Connect the RJ 45 cable from the Bridge to the

modem / router. The symbol will change to

100% green.

Page 83: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

83

3.5.5 Smart Phone or Tablet configuration - Using your App

Using your Myzone App3 in your local WiFi area

• Press the Myzone button on your phone or tablet.

• A nine digit number will appear on at the top of the screen. This is

you system ID number. Press on the nine digit number and you will

go into the App. Now you can name your system using the “Rename”

button.

To register your system for use outside your

local WiFi area press here. You must be

inside the WiFi area that your system is

connected to in order register your system .

Follow the prompts and complete all the

fields. You must get the address correct to

enable the correct weather data to be

displayed on the Nexus screen

World Wide Service

• You can only have access to the system from outside your

local WiFi range after you have successfully registered your

system on World Wide.

• To register your system you must :

• Be inside the WiFi area your system is connected to.

• On the App press Register Now.

• Complete all the fields making sure you get the Suburb,

State and Postcode 100% correct to ensure the correct

weather data is displayed on your Nexus screen (if fitted)

• You must agree to the Worldwide Terms.

• The App will display all the systems it finds on in this WiFi

area and will simultaneously register all devices displayed.

• Make sure you remember your password as you will need it

when you login via World Wide

• When you login to World Wide there is an option to save

your username and password (Login and Remember Me).

We recommend you select this option to make it faster and

easier to login to your system remotely.

• To reduce the data usage there may be a slight delay

between changing a setting on your phone, and the system

updating, when using World Wide.

• Do not use World Wide when you are in your WiFi zone

unless you have turned off the WiFi on your smart phone or

tablet.

000002195

Once you are registered for World Wide

access you can press here to access your

system

World Wide LoginWorld Wide LoginWorld Wide LoginWorld Wide Login

Page 84: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

84

3.6 Home automation integration

Myzone systems can be integrated into any home automation system that has an Ethernet interface. The WiFi bridge is fitted with an Ethernet

connection .

For interface specifications please contact Reece Pty Ltd.

Your home automation integrator will need to write suitable code to control your AC system. This service is not provided by Reece or Myzone.

Page 85: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

85

3.7 Myzone Naked 400 remote - Configuration

a) It will take around 5 minutes to complete Auto

configura�on. If you press any bu�on and Zones 12, 13,

& 14 are s�ll flashing rapidly this indicates the system is

s�ll configuring.

1. To pair the remote to the system . Press and hold the

pair bu�on on the remote and at the same �me press the

pair bu�on on the CM225 module. Zone 1 will flash blue

rapidly. You can also press the AC pair bu�on on a touch

screen if one is fi�ed to the system.

Note:

Zone 1 will be set as the

default constant zone when

Auto configured.

Hint:

Configure in this order:

1. Pair the remote to the CPU

first.

2. Force Auto configuration

3. Test air flows to each zone

and fit zone labels onto the

back of the remote.

4. To force the system to Auto configure:

a) Press and hold the Up bu�on then press and release the

pair bu�on.

b) Zones 12, 13, & 14 will flash rapidly indica�ng the system

is Auto configuring.

Page 86: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

86

3.8 Myzone Naked 410 remote - Configuration

3. To pair a wireless sensor to the system:

a) Set the dial inside the sensor to the correct zone number.

Press and hold the pair bu�on in the sensor

b) On the remote—Press and hold the zone bu�on then

press the pair bu�on. The blue LED on the sensor will

flash rapidly to indicate it is pairing.

4. To force the system to Auto configure:

a) Press and hold the up bu�on then press and release the

pair bu�on.

b) Zones 12, 13, & 14 will flash rapidly indica�ng the system

is Auto configuring.

c) It will take around 5 minutes to complete Auto

configura�on as it needs to receive data from each of the

zone sensors

1. To pair the remote to the system .

Press and hold the pair bu�on on the

remote and at the same �me press the

pair bu�on on the CM225 module . Zone

1 will flash blue rapidly. You can also

press the AC pair bu�on on a touch screen

if one is fi�ed to the system.

Note:

Zone 1 will be set as the

default constant zone when

Auto configured.

Hint:

Configure in this order:

1. Pair the remote to the CPU

first.

2. Then set the dial in the

zone sensors to the correct

zone number.

3. Pair each sensor to the

system.

4. Force Auto configuration

5. Test air flows to each zone

and fit zone labels onto the

back of the remote.

6. Test sensors by pressing

the sensor button to ensure

the correct zone is set to

Climate control.

Page 87: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

87

4.0 User manual (shown in Classic style)

4.1 Myzone 400 & 405 home

Myzone

Inventive . Intelligent

. Intuitive

Home screen Press to ac�vate a favourite

mode or to configure a new

favourite (4.9)

Press to ac�vate a schedule

or to configure a new

schedule (4.11)

Press to change screen

seEngs (4.14)

Press to get more help

about your Myzone system

A/C system maintenance

required. Press here for

instruc�ons.

System date and �me

Press to change zone

status (4.4)

Press to change zone

airflow (4.7)

Press to set system

�me (4.13)

Press to configure

system (3.0)

Press to ac�vate or

deac�vate this screens

audio feed back (beep

on touch)

Installing company’s tag line will

vary depending on the installa�on

company

• To get back to the Home

screen at any time press.

• When entering names or

values using the keyboard

it is easier to use a thin

object such as a toothpick.

Do not use sharp, hard

objects as they may

damage the screen. The

enter button must always

be pressed to save the

changes you have made.

• Some functions may have

been locked by your

installer to ensure the

commissioned values are

not changed. To make

changes to these values

contact your installation

company.

WiFi connec�on

Page 88: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

88

4.2 Myzone 410 - 435 home screen

• To get back to the Home

screen at any time press.

• When entering names or

values using the keyboard

it is easier to use a thin

object such as a toothpick.

Do not use sharp, hard

objects as they may

damage the screen. The

enter button must always

be pressed to save the

changes you have made.

• Some functions may have

been locked by your

installer to ensure the

commissioned values are

not changed. To make

changes to these values

contact your installation

company.

Press to ac�vate a favourite

mode or to configure a new

favourite (4.9).

Press to ac�vate a schedule

or to configure a new

schedule (4.11).

Press to change screen

seEngs (5.14).

Press to configure the

system (3.0).

A/C system maintenance

required or A/C unit fault

code. Press to clear

System date and �me.

Press to change zone

status (4.4).

Press to change zone

airflow (4.7).

Press to set system

�me and date (4.13).

Press to ac�vate or

deac�vate this screens

audio feed back (beep

on touch).

Tag line this will vary depending on

the installa�on company.

Press to toggle sleep �mer

op�ons.

Press to turn your system

on or off.

Press to change the A/C

unit seEngs (4.3).

iSave is Off

Press to switch iSave On

(Only applicable if iSave has

been fi�ed to the system

WiFi connec�on

Myzone

Inventive . Intelligent

. Intuitive

Page 89: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

89

Normal 22.0 C

System Status

Current AC unit set

point.

Press here to change

the mode.

Indicates the temperature measured

by this panel is currently controlling

the AC unit (Only applicable if

systems configured for “AC unit

controlling sensor—Master” op�on.

(See 3.3).

Indicates the current status of

the AC unit. If a fault code

appears here please contact

your installer.

4.3 AC unit control

Press here to increase the AC unit

set point. (Not applicable if “AC

unit controlling sensor—Zones”

op�on selected. See 3.3).

Press here to decrease the AC unit

set point (Not applicable if “AC unit

controlling sensor—Zones” op�on

selected. See 3.3).

Press here to change the fan

speed.

Press here to go back to the

home page.

AC unit actual temperature

(RA, sensor or touch screen)

Myzone

Inventive . Intelligent

. Intuitive

Page 90: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

90

Myzone

Inventive . Intelligent

. Intuitive

Indicates this zone is

currently in climate

control mode.

Zone Name. Press to

edit zone name and

other zone seEngs

(4.5).

Indicates this zone is

currently fully open.

Indicates this zone is

currently closed.

Indicates the hall is an

electronic constant and

it is currently ac�ve.

Scroll up or down to see more

zones.

4.4 Zone control

Indicates Zone 1 is in climate

control mode Press here to

change the Set point. (4.6).

Indicates this zone is closed.

Press here to open the zone.

Indicates this zone is open.

Press here to close the zone.

Indicates this zone is

currently being overridden

by the system and is being

used as a constant because

too many zones are closed.

Press here to go back to the

home page

Indicates there could be a

fault with this damper.

Contact your installer.

Auto

Auto

Auto

Auto

Page 91: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

91

4.5 Edit zone names & settings

Myzone

Inventive . Intelligent

. Intuitive

Press to edit zone name.

Press to edit current zone

status.

Press to change maximum

and minimum airflow set

points.

Current zone being

edited.

System zone number

and display name.

Zone maximum and

minimum air flow set

points.

Status of this zone if it

has been selected as an

electronic constant.

Current zone

status.

Room Area 16 sqm

Constant Zone Inac�ve

Room area (if Fan Auto

func�on has been

configured).

Page 92: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

92

4.6 Adjusting temperature controlled zones

Indicates current

zone being adjusted.

Indicates current temperature set point required for

this zone.

Press here to allow Myzone

to automa�cally control the

temperature in this zone.

Indicates the actual

temperature in this

zone (as measured by

Myzone).

Scroll up or down to see more

zones. Myzone

Inventive . Intelligent

. Intuitive

Press here to increase the current zone

set point temperature.

Press here to decrease the current zone

set point temperature.

Press here to select this zone as the

master (only available if configured for

Master AC unit control).

Indicates the current

temperature of the air

inside the air condi�oning

system ductwork.

Press here to go back to the

zone summary.

Indicates ba�ery in the sensor serving

this zone requires replacement. (only if

RF sensor is installed)

Indicates RF strength from sensor

serving this zone is acceptable (only if

RF sensor is installed.)

Press here to fully

open this zone.

Master Climate

Press here to close this zone.

Page 93: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

93

4.7 Zone airflow summary

Myzone

Inventive . Intelligent

. Intuitive

Zone name.

Scroll up or down to see

more zones.

Indicates current minimum

air flow seEng to this zone.

Indicates current maximum

air flow seEng to this zone.

Press here to change the

zone air flow seEngs.

Page 94: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

94

4.8 Changing zone airflows

Indicates current zone

that you are changing

the airflow to.

Indicates the current

maximum airflow seEng

for this zone.

Scroll up or down to see more

zones. Myzone

Inventive . Intelligent

. Intuitive

Press here to increase the

maximum airflow to this

zone.

Press here to go back to the

airflow summary.

Indicates the current

minimum airflow seEng for

this zone.

(This is usually set at 0%).

Min Airflow will not display if

this adjustment has been

locked.

Press here to decrease the

maximum airflow to this

zone.

Press here to increase the

minimum airflow to this

zone.

Press here to decrease the

minimum airflow to this

zone.

Please note: It is possible to lock the maximum and minimum

airflow seEngs in the configura�on menus. If you screen does not

display as indicated here and you require to make changes to

airflows please contact your installer to ac�vate your display.

Page 95: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

95

4.9 Favourites

Myzone

Inventive . Intelligent

. Intuitive

Press the favourite you would like and Myzone

will automa�cally change all the zones seEngs

for this favourite.

Indicates this favourite

has not been used.

Press here to setup and

edit favourites

Page 96: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

96

4.10 Assigning and editing favourites

Indicates current favourite

being changed.

Zone names.

Scroll up or down to see more

zones. Myzone

Inventive . Intelligent

. Intuitive

Press here to change the

name of this favourite.

Indicates what mode you

want each zone to operate

in when this favourite is

used. Change each zone

seEng to suit your

requirements for this

favourite.

Press here to go back to the

favourites summary.

Pressing the back bu�on will

save the favourite seEng

selected.

If you require a different

temperature to that

indicated, go to your zone

and change it first

Page 97: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

97

4.11 Schedules

Any of your favourites can be set to

automa�cally start at any �me of your

choosing. Press here to enable the �me based

schedule for favourite (PM Nap).

Press here to set up or edit a schedule

on any favourite

Indicates an automa�c �me

schedule has been enabled

for this favourite.

Indicates no automa�c �me

schedule has been enabled

for this favourite.

Myzone

Inventive . Intelligent

. Intuitive

Page 98: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

98

4.12 Setting and editing a schedule

Indicates current schedule

that you are changing or

seEng.

Indicates the start �me

for this schedule.

Press next to see the next schedule.

Myzone

Inventive . Intelligent

. Intuitive

Indicates the days this

schedule will apply. Press to

stop the schedule running

on this day.

Press here to go back to the

schedule summary.

Press here to clear this

schedule.

Press the key pad to change

the �me. Remember it is in 24

hour format so for 2:30 am

type in 0230.

Press the enter bu�on to

save your new seEng.

Indicates the days this

schedule will not run.

Press the day you want

the schedule to apply to.

START-08:00

STOP-17:30 Indicates the stop �me for

this schedule.

Page 99: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

99

4.13 Setting the time

Myzone

Inventive . Intelligent

. Intuitive

Current �me.

Indicates the minutes are be

changed.

You must press the enter

bu�on to save the changes

you have made.

Current date.

Press the le� or right arrows to

move to the value you want to

change.

Page 100: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

100

4.14 Changing the home screen colour

Slide le� / right to adjust

the screen brightness.

Myzone

Inventive . Intelligent

. Intuitive

Slide le� / right to adjust the

screen contrast.

Press here to go back to the

home screen.

Press the colour you would

like for your home screen.

Fine adjustments to the

shade, tone, hue can be

made using the brightness,

contrast and satura�on

slides.

Slide le� / right to adjust

the screen satura�on.

Modern

Press here to change the

graphics from Classic to

Modern style.

Landscape

Press here to change the

graphics from Classic Portrait

to Classic Landscape.

Page 101: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

101

4.15 iSense controller

Press to adjust the maximum airflow to

this zone. Use the up and down arrows to

adjust the maximum airflow required to

this zone

Indicates zone name this unit is controlling

Indicates the iSense has been

ac�vated on this controller.

Note:

When iSense has been ac�vated

movement is required in the range of the

occupancy sensor to keep the zone

opera�ng. The use of the iSense feature in

bedrooms, when occupants are sleeping, is

not recommended.

System reset bu�on under

here

Press to Open this zone fully

Indicates zone setpoint temperature

Indicates system �me

Indicates the air temperature inside

the supply air duct Indicates the maximum airflow set for this

zone

Indicates the current zone

temperature

Press to Close this zone fully

Press to ac�vate or de-ac�vate the iSense

occupancy sensor

Press to Climate control this zone. Adjust

required set-point temperature using the

up and down arrows

Page 102: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

102

4.16 Myzone Naked 400 remote - User manual

Press to toggle the maximum airflow in

the current zone

Flashing red indicates this zone is faulty

Press here to move up to the next zone or if pressed a�er the

air% bu�on it will increase the maximum airflow %

Press the enter bu�on to send the changes. If the enter bu�on

is not pressed the changes will be sent a�er approximately 10

seconds Solid red indicates this zone is currently

closed

Press here to toggle through the zones

If two LED’s are illuminated the seEng is in

the middle (eg.95%)

Press to open the current zone

Press here to move down to the next zone or if pressed a�er

the air% bu�on it will decrease the maximum airflow %

Press to close the current zone

Solid green indicates this zone is currently

open

Solid blue indicates this zone is currently in

climate control mode. You are not able to

change the zone setpoint temperature with

this remote control. If you change this zone

you can only toggle between open and

closed

Indicates maximum air flow that the zone

has been set to

Pair bu�on only to be used for

configura�on

Page 103: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

103

4.17 Myzone Naked 410 remote - User

manual

Press to toggle the maximum airflow in the current zone

Flashing red indicates this zone is faulty

Press here to change the system mode. When pressed the

system setpoint temperature and fan speed will also be

displayed

Press the enter bu�on to transmit your changes. If the enter

bu�on is not pressed the changes will be sent a�er approximately

10 seconds

Solid red indicates this zone is currently closed

Press here to toggle through the zones or use the up down arrows

If two LED’s are illuminated the seEng is In the

middle (29oC or 95%)

Press to open the current zone

Press to close the current zone

Solid green indicates this zone is currently

open

Solid blue indicates this zone is currently in

climate control mode.

Indicates maximum air flow that the zone has

been set to

Pair bu�on only to be used for configura�on

Press here turn the system on or off.

All connected zones will display red if the system is off. If the

system is currently on all connected zones will display green.

Press Mode or Fan then the up / down bu�ons to change the

system setpoint temperature. (only applicable in running on RA)

Press Zone then the up / down bu�ons to change the zone

number.

Press Air% then the up / down bu�ons to change the maximum air

flow percentage in the selected zone

Press here to toggle the system fan speed. When pressed the

system setpoint temperature and mode will also be displayed

Press to set the current zone to climate control. (Only applicable

if a zone sensor has been installed and set up.) A�er seEng to

Climate control you can adjust the zone setpoint temperature by

using the up down arrows or just toggle the climate bu�on.

Indicates setpoint temperature for AC unit or

for zone

Indicates fan speed is currently medium.

Indicates the mode is currently set to hea�ng. Press the

Mode bu�on to change the mode

Page 104: Installation, Configuration & User Manual for Myzone3 ...€¦ · Installation, Configuration & User Manual for Myzone3 series 400 to 435 Air Conditioning Control Systems Reece Pty

104

5.0 Further assistance

Rev 9 — 17/05/18

1. If you require warranty or maintenance on your air conditioning system or your MyZone system you should contact your installation

company.

2. If you want to add more zones or temperature control to any zone you should contact your installation company.

Reece Pty Ltd 118 Burwood Highway Burwood Victoria 3125 Australia Tel: 1800 032 566 Made in China


Recommended