+ All Categories
Home > Documents > INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or...

INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or...

Date post: 07-Apr-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
6
waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 INSTALLATION INSTRUCTION HARDWARE WARNING IMPORTANT: NEVER attempt any work without shutting off the electricity. - Read all instructions before installing. - System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations. - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the fixture or room that you are working on. - Place the wall switch in the “OFF” position. CAUTION - All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this fixture. CAUTION When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only. AVERTISSEMENT IMPORTANT : Coupez l’électricité avant TOUTE manipulation. - Lisez toutes les instructions avant d’installer. - Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »). MISE EN GARDE - Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base. ADVERTENCIA IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara. - Sistema está disenado para ser instalado por un electricista calificado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO). PRECAUCIÓN - Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calificación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo. WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. G0 WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861 358 – LED Wall Sconce Wire Connector Qty: 3pcs+1 Extra Mounting Screw Qty:2pcs+1 Extra 7EAC112201 A Plastic Anchor Qty: 2pcs+1 Extra Wood Screw Qty: 2pcs+1 Extra Ф4X22 4MPF0308S3W5(WT) 1/8"-40X3/8 Nickel Plating/White C E B Silicon Gasket Qty:2pcs F D Decorative Plate Qty:1pc 4MBA121244BA(AL) 4MBA121244W10(WT) 7TGD272501CL 1/8”-40x1 7MPF0308S1(AL) 7TDD082401 7MPF2204J2 Assembly Screw Qty:2pcs+1 Extra G Nickel Plating
Transcript
Page 1: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

ScrewQty:1 Extra

1/8"-40×1/2 Chrome Plating

Optional Metal CapQty:1 Extra

Chrome Plating

Wire ConnectorQty: 3pcs+1 Extra

P3

Junction Box ScrewQty: 2pcs+1 Extra

8#-32×13/16Nickel Plating

Mounting ScrewQty:1 Extra

5/32"-32×1/2Chrome Plating

A D EB C

PD-27802278-LED Pendant

Wire Connector

Qty: 3pcs+1 Extra

P3

Junction Box Screw

Qty: 2pcs+1 Extra

8#-32×13/16

Nickel Plating

Mounting Screw

Qty:1 Extra

5/32"-32×1/2

Chrome Plating

A B C

WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861

358 – LED Wall Sconce

Wire ConnectorQty: 3pcs+1 Extra

Mounting ScrewQty:2pcs+1 Extra

7EAC112201

A

Plastic Anchor Qty: 2pcs+1 Extra

Wood Screw Qty: 2pcs+1 Extra

Ф4X224MPF0308S3W5(WT)1/8"-40X3/8

Nickel Plating/White

C EB

Silicon GasketQty:2pcs

FD

Decorative PlateQty:1pc

4MBA121244BA(AL)4MBA121244W10(WT)

7TGD272501CL1/8”-40x17MPF0308S1(AL) 7TDD082401 7MPF2204J2

Assembly ScrewQty:2pcs+1 Extra

G

Nickel Plating

Page 2: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for

installation.

MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of

the mounting back plate marked “GND” must face out.

CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in

Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.

COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).

4 1/8”

15”11 3/4”

1 3/8”

1 3/4”

WS-75818MOUNTING BACK PLATE

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

FIG.1 Junction Box Screw

Junction Box

Wire Connector

Driver

Plastic Anchor

Mounting Plate

Wood Screw

Mounting Screw

B

A

D

C

E

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

Plate

Ground Wire Screw

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

Plastic

D

C

B

A

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

3. Remove the mounting screw (C) from the fixture.

5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

6. Secure the canopy to the mounting plate using the mounting screw (C).

4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

PD-27802278-LED Pendant

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

10 5

/16"

1 3/4"

1 3/

8"

3. Remove the mounting screw (C) from the canopy.

6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

Ground Wire Screw

Plate

C

B

A

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

7. Hook the safety cord to the mounting plate.

8. Secure the canopy to the mounting plate using the mounting screw (C).

WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861

358 – LED Wall Sconce

Fig.1

Fig.2

A Wire Connector

Plastic AnchorF

Mounting ScrewBWood ScrewG

Acrylic Diffuser PC strip

Decorative Plate

Junction Box

Assembly Screw

Silicon Gasket

Ground Wire

D

End Cap

E

C

Wire Connector

Plastic Anchor

Mounting ScrewWood Screw

Acrylic Diffuser PC strip

Wall Hole

Ground Wire

A

B

End Cap

F

G

Page 3: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for

installation.

MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of

the mounting back plate marked “GND” must face out.

CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in

Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.

COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).

4 1/8”

15”11 3/4”

1 3/8”

1 3/4”

WS-75818MOUNTING BACK PLATE

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

FIG.1 Junction Box Screw

Junction Box

Wire Connector

Driver

Plastic Anchor

Mounting Plate

Wood Screw

Mounting Screw

B

A

D

C

E

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

Plate

Ground Wire Screw

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

Plastic

D

C

B

A

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

3. Remove the mounting screw (C) from the fixture.

5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

6. Secure the canopy to the mounting plate using the mounting screw (C).

4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

PD-27802278-LED Pendant

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

10 5

/16"

1 3/4"

1 3/

8"

3. Remove the mounting screw (C) from the canopy.

6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

Ground Wire Screw

Plate

C

B

A

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

7. Hook the safety cord to the mounting plate.

8. Secure the canopy to the mounting plate using the mounting screw (C).

WS-35819/ WS-35825/ WS-35837/ WS-35849/WS-35861

358 – LED Wall Sconce

Junction Box / Wall Hole

WS-35819: 18 1/4"WS-35825: 24 3/16"WS-35837: 36 1/4"WS-35849: 48 1/4"WS-35861: 59 13/16"

Installation Location

4. Secure the decorative plate (E) to the fixture with assembly screw (C), then replace the existing silicon gasket with the supplied silicon gasket (D).

5. Remove the mounting screw (B) and the end cap from the fixture.

3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F). Line up the center line of the drill holes with respect to the center line of the junction box to allow the decorative plate (E) properly cover up the junction box opening on the wall.

8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.

MOUNT ON THE JUNCTION BOX (Fig. 1)

MOUNT WITHOUT JUNCTION BOX (Fig. 2)

OR

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

PREPARATION

6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the junction box.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G), make sure to align the decorative plate to adequately cover the junction box wall opening.

4. Remove the mounting screw (B) and the end cap from the fixture.5. Drill a small access hole in the wall behind the fixture and pull the house wires through the wall.

3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).

8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.

6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the wall hole.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.3 Wiring

3

Page 4: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

ScrewQty:1 Extra

1/8"-40×1/2 Chrome Plating

Optional Metal CapQty:1 Extra

Chrome Plating

Wire ConnectorQty: 3pcs+1 Extra

P3

Junction Box ScrewQty: 2pcs+1 Extra

8#-32×13/16Nickel Plating

Mounting ScrewQty:1 Extra

5/32"-32×1/2Chrome Plating

A D EB C

PD-27802278-LED Pendant

Wire Connector

Qty: 3pcs+1 Extra

P3

Junction Box Screw

Qty: 2pcs+1 Extra

8#-32×13/16

Nickel Plating

Mounting Screw

Qty:1 Extra

5/32"-32×1/2

Chrome Plating

A B C

WS-35873/WS-35897358 – LED Wall Sconce

Wire ConnectorQty: 3pcs+1 Extra

Mounting ScrewQty:2pcs+1 Extra

7EAC112201

A

Plastic Anchor Qty: 6pcs+1 Extra

Wood Screw Qty: 2pcs+1 Extra

Ф4X224MPF0308S3W5(WT)1/8"-40X3/8

Nickel Plating/White

C EB

Silicon GasketQty:2pcs

FD

Decorative PlateQty:1pc

4MBA121244BA(AL)4MBA121244W10(WT)

7TGD272501CL1/8”-40x17MPF0308S1(AL) 7TDD082401 7MPF2204J2

Assembly ScrewQty:2pcs+1 Extra

G

Nickel Plating

Tapping ScrewQty: 4pcs+1 Extra

7MPF033502

H

Page 5: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for

installation.

MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of

the mounting back plate marked “GND” must face out.

CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in

Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.

COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).

4 1/8”

15”11 3/4”

1 3/8”

1 3/4”

WS-75818MOUNTING BACK PLATE

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

FIG.1 Junction Box Screw

Junction Box

Wire Connector

Driver

Plastic Anchor

Mounting Plate

Wood Screw

Mounting Screw

B

A

D

C

E

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

Plate

Ground Wire Screw

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

Plastic

D

C

B

A

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

3. Remove the mounting screw (C) from the fixture.

5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

6. Secure the canopy to the mounting plate using the mounting screw (C).

4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

PD-27802278-LED Pendant

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

10 5

/16"

1 3/4"

1 3/

8"

3. Remove the mounting screw (C) from the canopy.

6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

Ground Wire Screw

Plate

C

B

A

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

7. Hook the safety cord to the mounting plate.

8. Secure the canopy to the mounting plate using the mounting screw (C).

WS-35873/WS-35897358 – LED Wall Sconce

Fig.1

Fig.2

Installation Location

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.3 Wiring

A Wire ConnectorPlastic AnchorF

Wood ScrewG

Acrylic DiffuserPC strip

Mounting ScrewB

End Cap Decorative Plate

Assembly Screw

Silicon Gasket

Ground Wire

Junction Box

D

E

C

Wire Connector

Plastic Anchor

Wood Screw

Acrylic Diffuser PC strip

Mounting Screw

End Cap

Tapping Screw

B

A

Ground Wire

F

GH

Junction Box / Wall Hole

****

WS-35873: 72 1/4"WS-35897: 96 5/16"

WS-35873: 56 1/8"WS-35897: 80 3/16"

(If necessary)

13/1

6"

Page 6: INSTALLATION INSTRUCTION 877-LED Pendant 278-LED Pendant ...€¦ · - Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for

installation.

MOUNTING THE FIXTURE (Fig. 1)3. Remove the mounting screw (E) from the mounting back plate.4. Drill holes in the wall aligned with the key holes located in the mounting back plate, insert the plastic anchors (D).5. Secure the mounting plate to the junction box using junction box screws (B), fasten it to the wall using wood screws (C). The side of

the mounting back plate marked “GND” must face out.

CONNECTING THE WIRES (Fig. 2)6. Connect the driver input/output wires to junction box wires as shown in

Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box. * Requires Driver to be recessed within the junction box.

COMPLETING THE INSTALLATION (Fig. 1)7. Secure the �xture to the mounting back plate using the mounting screw (E).

4 1/8”

15”11 3/4”

1 3/8”

1 3/4”

WS-75818MOUNTING BACK PLATE

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

FIG.1 Junction Box Screw

Junction Box

Wire Connector

Driver

Plastic Anchor

Mounting Plate

Wood Screw

Mounting Screw

B

A

D

C

E

PD-87741877-LED Pendant

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

INSTALLATION INSTRUCTION758 – LED Wall SconceWS-75818

HARDWARE

A B C D E

Wire ConnectorQty: 3pcs+1 Extra7EAC112201

Junction Box ScrewQty: 2pcs+1 Extra7MPF0820C1#8-32x13/16Nickel Plating

Wood Screw Qty: 2pcs+1 Extra7MPF2204J2Ф4X22

Plastic Anchor Qty: 2pcs+1 Extra7TDD082401

Mounting ScrewQty: 1 Extra7MPF0412S1(AL)5/32-32x1/2Nickel Plating

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

G0

Plate

Ground Wire Screw

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

Plastic

D

C

B

A

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

3. Remove the mounting screw (C) from the fixture.

5. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

6. Secure the canopy to the mounting plate using the mounting screw (C).

4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

7. There is optional metal clip in hardware bag, remove the screw (D) to replace the plastic clip, secure the metal clip with screw (D).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

PD-27802278-LED Pendant

2WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program.

waclighting.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

INSTALLATION INSTRUCTION131 - LED Flush MountFM-13114

PREPARATION 1. Shut o� the power at the circuit breaker and remove existing �xture, including the crossbar.2. Carefully unpack your new �xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

CONNECTING THE WIRES (Fig. 2)3. Remove the mounting screws (C1) from �xture. 4. Drill holes in the ceiling aligned with the key holes located in the mounting plate, insert the plastic anchors (D1).5. Connect the �xture’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.

If your outlet box has a green or bare copper ground wire, connect the �xture’s ground wire to it. Otherwise, connect the �xture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

MOUNTING THE FIXTURE (Fig. 1)6. Secure the mounting plate to the junction box using junction box screws (B1),

fasten it to the wall using wood screw (E1). The side of the mounting back plate marked “GND” must face out.

7. Insert the PC di�user into the �xture shade.8. Secure the �xture onto mounting plate with mounting screws (C1).

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig. 2 Wiring

Plastic Anchor

Wire Connector

Wood Screw

Junction Box Screw

Mounting Screw

Fixture Shade

PC Di�user

Mounting Plate

Junction Box

Glass(RPL-GLA-13114)

Shade(RPL-SHA-13114)

D1

A1

E1

B1

C1

FIG. 1

Ø7"

Back Plate Dimensions

GND

Ø8 3/4"

Ø2 3/4"

Ø3 1/2"

FM-16818168-LED Flush Mount

1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

Junction Box

Mounting Plate

Fixture Shade

PC Diffuser

Wire Connector

Plastic Anchor

Wood Screw

Junction Box Screw

Mounting Screw Glass(RPL-GLA-13114)

Shade(RPL-SHA-16818)

Diffuser(RPL-DIF-13114)

G0 1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017

modernforms.comPhone (800) 526.2588Fax (800) 526.2585

Headquarters/Eastern Distribution Center44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center1600 Distribution CtLithia Springs, GA 30122

Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760

HARDWARE

WARNINGIMPORTANT: NEVER attempt any work without shutting o� the electricity.- Read all instructions before installing.- System is intended for installation by a quali�ed electrician in accordance with the National Electrical Code and local regulations.- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF” the circuit breaker switch(es) that control the power to the �xture or room that you are working on.- Place the wall switch in the “OFF” position.

CAUTION- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this �xture. CAUTION When handling the �xture, do not apply pressure to the LEDs. Hold the �xture by the base only.

AVERTISSEMENTIMPORTANT : Coupez l’électricité avant TOUTE manipulation.- Lisez toutes les instructions avant d’installer.- Système est destiné à être installé par un électricien quali�é en conformité avec le code national de l’électricité et les règlements locaux. - Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »). - Placez l’interrupteur mural en position d’arrêt (« OFF »).

MISE EN GARDE- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.

ADVERTENCIAIMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico. - Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta lámpara.- Sistema está disenado para ser instalado por un electricista cali�cado, de acuerdo con el código eléctrico nacional y las normas locales. - Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación principal en la posición “OFF” (APAGADO). - Coloque el interruptor de la pared en la posición “OFF” (APAGADO).

PRECAUCIÓN- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la cali�cación ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.

INSTALLATION INSTRUCTIONSlat - Vanities & Wall SconcesWS-80618/WS-80624/WS-80636

Wire ConnectorQty: 3 pcs

7EAC112201

MountingRing

Qty: 1 pc7MBC101501

Transformer

Qty: 1 pc5EN-2460-R2

JunctionBox ScrewQty: 2 pcs+ 1 Extra

7MPF0825C18-32x1 SS

ConversionPlate

Qty: 1 pc4MBA151110BA

MountingScrew

Qty: 2 pcs+ 1 Extra

7MPF0415C28-32x9/16 SS

SetScrew

Qty: 2 Extra7MPF0308S15/32-32x5/16Nickel Plating

MountingAnchor

Qty: 2 pcs7TDD082401

TappingScrew

Qty: 2 pcs7MPF2204J2

Ø4x22

A1 B1 C1 D1 E1 F1 G1 H1 I1

( C )

( C )

( E )

( D )

( B )

( A )

10 5

/16"

1 3/4"

1 3/

8"

3. Remove the mounting screw (C) from the canopy.

6. Secure the mounting back plate to the junction box using junction box screws (B).The side of the mounting back plate marked “GND” must face out.

4. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired. Make sure the wires are the same length.5. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.

CONNECTING THE WIRES (Fig. 2)

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not lose any small parts necessary for installation.

PREPARATION

MOUNTING THE FIXTURE(Fig.1)

Fixture WiresBlack or Smooth

Fixture WiresWhite or Ribbed

Fixture WiresBare wire(Ground)

House WiresBlack(Hot)

House WiresWhite (Neutral)

House WiresGreen or Bare Copper(Ground)

Fig.2 Wiring

Ground Wire Screw

Plate

C

B

A

3 3/8" L X 2 3/8" W X 1 1/4" H Driver

7. Hook the safety cord to the mounting plate.

8. Secure the canopy to the mounting plate using the mounting screw (C).

WS-35873/WS-35897358 – LED Wall Sconce

4. Secure the decorative plate (E) to the fixture with assembly screw (C), then replace the existing silicon gasket with the supplied silicon gasket (D)

5. Remove the mounting screw (B) and the end cap from the fixture.

3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).Line up the center line of the drill holes with respect to the center line of the junction box to allow the decorative plate (E) properly cover up the junction box opening on the wall.

8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser.

MOUNT ON THE JUNCTION BOX (Fig. 1)

MOUNT WITHOUT JUNCTION BOX (Fig. 2)

OR

1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.

PREPARATION

6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the junction box.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G), make sure to align the decorative plate to adequately cover the junction box wall opening.

4. Remove the mounting screw (B) and the end cap from the fixture.5. Drill a small access hole in the wall behind the fixture and pull the house wires through the wall.

3. Drill a fixture mounting hole according to (installation location), insert the plastic anchor (F).

8. Secure the end cap to the fixture using mounting screw (B) to seal the acrylic diffuser. * If the fixture and wall have a large gap, tapping screw (H) can be used when installing the fixture.

6. Connect the fixture’s wires to house wires as shown in Fig.3, making sure that all wire connectors (A) are secured. If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, tuck the fixture’s ground wire directly to the fixture. After wires are connected, tuck them carefully inside the wall hole.7. Slide acrylic diffuser and PC strip slightly out of the way to review the plastic anchor location on the back, then fasten the fixture to the wall using wood screw (G).

3


Recommended