e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 1 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Installation Instructions for Med Touch Master Alarms - Wireless
Master Alarm Panel – Local Sending
Master Alarm Panel - Receiving
Master Alarm Panel - Repeater
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 2 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Install the hinge brackets onto
the lower flange of the box,
tighten with mounting screws.
After removing the flange nut,
slide the Antenna through the
designated hole at the top of
the back box, and slide the
bracket over the mounting
flange stud.
Once all of the connections are made,
turn the switch to “ON” from the Power
Supply. Close the Alarm Front and
tighten the center screw for a completed
finish.
Once the Antenna is through
the designated hole and the
bracket is adjusted, reinstall
the nut and tighten into
position
Power Supply Harness
Attach the Alarm Front to the hinge brackets, and
insert the lanyard mounting screws though the
lanyards and tightening onto the box studs.
(Lanyard Mounting Screws shipped w/ the Back Box)
Attach the Ground Wire to the Alarm Front Panel, and also
attach the Top Antenna Cable to the outside mating connector.
Once your connections are made, attach the Power Supply
Harness Plug as shown above. (See Figure 2 on Sheet 3)
Common Master Alarm Back Box Assembly Assembling the Master Alarms Bock Box: After installing the Back Box in the wall (The antenna can be mounted out the top or bottom of the Back Box)
1 2 3 4
Connection for Master Local Source Sending Panel Wireless Alarm
5
6
7
Remove the mounting flange nut
from the Top Left hand corner.
Flange Nut
Top Antenna Ribbon
Cable connection
Power Supply
Connection Attach Ground
Wire
Flange Nut
Hinge
Bracket
Lanyards
Mounting
Screws
Top Antenna
Ribbon
Power Supply
Harness
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 3 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Figure 2 – Master Local Source Sending Panel Wireless Alarm
Power Ribbon Cable
Power Button Board
Master Boards
Sending Board
Outside Connector
for Antenna Master Ribbon
Power Cable
Top Antenna
Ribbon Cable
Network Position “A”
Jumper Connector
Network Position “B”
Jumper Connector
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 4 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Once all of the connections are made,
turn the switch to “ON” from the Power
Supply. Close the Alarm Front and
tighten the center screw for a completed
finish.
Attach the Ground Wire to the Alarm Front Panel, and also
attach the Top Antenna Cable to the mating connector. Once
your connections are made, attach the Power Supply Plug and
the Receiving Power Plug connectors, both connectors are on
the same Harness as shown above. (See Figure 3 on Sheet 5)
Attach the Alarm Front to the hinge brackets, and
inserting the lanyard mounting screws though the
lanyards and tightening onto the box studs.
(Lanyard Mounting Screw shipped w/ the Back Box)
Connection for Master Receiving Panel Wireless Alarm
8 9
10
Power Supply
connection
Attach Ground
Wire
Lanyards
Mounting
Screws Antenna Ribbon
Antenna Ribbon
Cable connection Receiving
Power
Connection
Receiver Ribbon
Cable Assembly
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 5 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Figure 3 – Master Receiving Panel Wireless Alarm
Power Supply and
Receiving Power Supply Harness
Module
Ribbon
Cable
Button Power Board
Receiving
Ribbon
Cable
Receiving
Board
Master
Receiving
Board
Antenna
Ribbon
Cable
Ground
Attachment
Point
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 6 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
Once all of the connections are
made, turn the switch to “ON” from
the Power Supply. Close the Alarm
Front and tighten the center screw
for a completed finish.
Attach the Alarm Front to the hinge brackets, and inserting the
lanyard mounting screws though the lanyards and tightening
onto the box studs.
(Lanyard Mounting Screws are shipped w/ the Back Box)
Attach the Ground Wire to the Alarm Front Panel, and also
attach the Top Antenna Cable to the mating connector. Once
your connections are made, attach the Power Supply Plug
connector as shown above.
Components for the Repeater
Alarm
Connection for Master Repeater Panel Wireless Alarm
11 12 13
Figure 4
Antenna
Assembly
Back Box
Hinge
Brackets
Mounting Hardware
Power Supply
Harness
Antenna Ribbon
Lanyards
Lanyard Mounting
Screws
Master Repeater
Alarm Front
Master Repeater Alarm Front
Antenna Ribbon
Antenna Assembly
Button Board
Power Harness Connection
e6622rIR 11/26/18 Tri-Tech Medical, Inc. 35401 Avon Commerce Parkway, Avon, Ohio 44011 No. 99-0512
Tel 80 0-253-8692 or 440-937-6244 Fax. 440-937-5060 Web-site www.tri-techmedical.com Page 7 of 7
Tri-Tech
Medical Inc.
Medical Gas Master
Panel Alarms - Wireless
This page is left Intentionally Blank
Tri-Tech
Medical Inc.