36
INSTALLATION MANUAL www.invisirail.com
Transcript
Page 1: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

INSTALLATION MANUAL w w w. inv i s i ra i l . com

Page 2: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART
Page 3: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

4 PRE-INSTALLATION REQUIREMENTS

4 BOLT SIZE CHART

5 POST BLOCKING DETAILS

6 POST INSTALLATION

6 ON-CENTRE POST MEASUREMENT CHART

7 FASCIA MOUNT POST CONNECTION DETAILS

8 GLASS SPECIFICATIONS

8 CONCRETE CONNECTION DETAILS

9 SPACER INFORMATION

10 - 11 STAINLESS STEEL HANDRAIL TOP MOUNT INSTALLATION

12 STAINLESS STEEL GLASS CONNECTOR INSTALLATION General Information InvisiPost - Connector to Connector InvisiPost - Connector to Universal Angle Bracket

13 InvisiPost - Universal Angle Bracket to Universal Angle Bracket InvisiPost - End Post with Connector

14 InvisiPost - End Post with Universal Angle Bracket VISTA POST and WOOD POST CONNECTOR INSTALLATION Straight Run Connector

15 Universal Angle Bracket

16 LITE 10 NYLON GLASS CONNECTOR INSTALLATION Lite 10 Angle Bracket

17 GLASS PANEL INSTALLATION Stainless Steel Connectors Lite 10 Connectors

18 STAIR GLASS and CUSTOM HORIZONTAL GLASS

19 INVISIPOST POSITIONING DETAIL DIAGRAMS House or End of Run Beside Stairs Inside 90 degrees Outside 90 degrees

20 Inside 90 degrees split

Outside 90 degrees split Inside 45 degrees Outside 45 degrees

21 Inside 45 degrees split Outside 45 degrees split Inside 22.5 degrees split Outside 22.5 degrees split

22 InvisiPost Flange Base

23 ALX POST POSITIONING DETAIL DIAGRAMS House or End of Run Inside 45 degrees split Outside 45 degrees split Inside 22.5 degrees split Outside 22.5 degrees split

24 ALX Post Flange Base

25 VISTA POST POSITIONING DETAIL DIAGRAMS House or End of Run Beside Stairs Inside 90 degrees Outside 90 degrees

26 Inside 45 degrees w/stainless steel connectors

Outside 45 degrees w/stainless steel connectors Inside 45 degrees w/Lite 10 connectors Outside 45 degrees w/Lite 10 connectors

27 Inside 45 degrees split w/stainless steel connectors Outside 45 degrees split w/stainless steel connectors Inside 45 degrees split w/Lite 10 connectors Outside 45 degrees split w/Lite 10 connectors

28 Vista Post Flange Base

29 INVISIPOST FASCIA MOUNT POSITIONING DIAGRAMS

Corner Post Inside 90 degrees Outside 90 degrees Inside 45 degrees

30 Outside 45 degrees Beside Stairs

31 VISTA POST FASCIA MOUNT POSITIONING DIAGRAMS

Corner Post Inside 90 degrees Outside 90 degrees

32 Inside 45 degrees w/stainless steel connectors Inside 45 degrees w/Lite 10 connectors

33 CUSTOM HORIZONTAL GLASS ORDER FORM

34 INVISIRAIL SCRATCH PAD

3

Page 4: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

4

PRE-INSTALLATION

BOLT CHART

Connector to Universal Angle Bracket

TOOLS / SUPPLIES REQUIRED:• Two (2) people are necessary to handle and install glass• Tape measure• Bolts as specified on the InvisiRail Bolt Chart• Drill with assorted bits including a T-40 bit for deck fasteners and a 10mm hex socket if connecting to aluminum or wood posts• Shims for fine height adjustment to help in pin alignment during glass installation• Washers for flange base adjustment to ensure posts are plumb during installation• Two (2) short pieces of 2”x4” or 4”x4” to support glass during installation• Pipe cutter or saw with carbide-tipped metal cutting blade if installing stainless steel handrail or top rail

There must be proper blocking in joists to secure posts!

Page 5: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

5

BLOCKING DETAIL

4” LONG HEADLOKSCREWS (0.188” DIA)

REFER TO SECTIONFOR PLACEMENT

HEADLOKSCREWS

4” LONG HEADLOKSCREWS (0.188” DIA)3 TOTAL

5/16” X 6” GRK RSS SELF-DRILLING SCREWS

ELEVATION

DECKING MATERIAL BETWEEN BASE PLATE AND JOISTS

INVISIPOST

VISTA POST WITH BASE PLATE

ALTERNATIVE BLOCKING DETAIL

(4) 5/16” X 6” GRK RSS SELF-DRILLING SCREWS

(4) 3/8” X 5” LAG SCREWS EACH END

Page 6: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

6

Only install one section at a time.

DO nOT InSTall all POSTS BefORe InSTallIng glaSS as minor adjustments may be needed to the post.

Start with the post indicated on the layout diagram sent with your order.

If necessary, use washer/s beneath the flange base to ensure your post is completely plumb.

Refer to the post positioning diagrams in the back of this manual that apply to your layout.

Set the next post according to the on-centre chart below and the glass panel indicated on your layout diagram.

POST INSTALLATION

2.50

.31

4.75

.38

42.19

2.88

.75

33.50

A 6X .38 THRU ALL

0 .38 1.13 2.88 3.63 4.38 4.75

0

.38

1.2

5 2

.13

2.5

0

DETAIL ASCALE 1 : 4

DO NOT SCALE DRAWING

NIS 4247-002SHEET 1 OF 1

UNLESS OTHERWISESPECIFIED:

SCALE: 1:8 WEIGHT: 9.77

REVDWG. NO.

BSIZE

DESCRIPTION:

NAME DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:WELDMENTS 1/8FRACTIONAL 1/32BEND 2DEG.TWO PLACE DECIMAL .01THREE PLACE DECIMAL .003

REVISION

DATELEVEL

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFNEUFELDT INDUSTRIAL SERVICES INC. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFNEUFELDT INDUSTRIAL SERVICES INC. IS PROHIBITED.

PHONE:(651) 388-4347FAX:(651) 388-5976P.O. BOX 51, RED WING, MN 55066

CUSTOMER:

PROJECT:K. MERKLE

GLASS RAILINGPOST WELDMENT (FLUSH MOUNT)

GLN 05/24/17JUSTIN

NONEAISI 304

2.50

.31

4.75

.38

42.19

2.88

.75

33.50

A 6X .38 THRU ALL

0 .38 1.13 2.88 3.63 4.38 4.75

0

.38

1.2

5 2

.13

2.5

0

DETAIL ASCALE 1 : 4

DO NOT SCALE DRAWING

NIS 4247-002SHEET 1 OF 1

UNLESS OTHERWISESPECIFIED:

SCALE: 1:8 WEIGHT: 9.77

REVDWG. NO.

BSIZE

DESCRIPTION:

NAME DATE

COMMENTS:

Q.A.

MFG APPR.

ENG APPR.

CHECKED

DRAWN

FINISH

MATERIAL

DIMENSIONS ARE IN INCHES

TOLERANCES:WELDMENTS 1/8FRACTIONAL 1/32BEND 2DEG.TWO PLACE DECIMAL .01THREE PLACE DECIMAL .003

REVISION

DATELEVEL

PROPRIETARY AND CONFIDENTIALTHE INFORMATION CONTAINED IN THISDRAWING IS THE SOLE PROPERTY OFNEUFELDT INDUSTRIAL SERVICES INC. ANY REPRODUCTION IN PART OR AS A WHOLEWITHOUT THE WRITTEN PERMISSION OFNEUFELDT INDUSTRIAL SERVICES INC. IS PROHIBITED.

PHONE:(651) 388-4347FAX:(651) 388-5976P.O. BOX 51, RED WING, MN 55066

CUSTOMER:

PROJECT:K. MERKLE

GLASS RAILINGPOST WELDMENT (FLUSH MOUNT)

GLN 05/24/17JUSTIN

NONEAISI 304

ON-CENTRE CHART

69 13/1667 7/865 5/1662 5/1659 5/1657 13/1655 7/853 5/1651 13/1649 7/847 5/1644 5/1641 5/1638 5/1635 5/1632 5/1629 5/1623 5/1617 5/1611 5/16

1/8

5/85/85/81/8

5/81/16

5/85/85/85/85/85/85/85/85/85/8 1/2

1/21/21/21/21/21/21/21/21/2

1/2

1/21/21/2 3/4

3/43/41/41/43/41/41/43/43/43/43/43/43/43/43/43/43/4 3/4

3/43/43/43/43/43/43/43/43/41/41/43/4

3/43/4

1/41/4

3/43/41/41/41/43/43/4

3/43/4

1/4

1/41/41/41/41/41/41/41/41/41/4 1/4

1/41/41/41/41/41/41/41/41/4

1/4

1/41/41/43/4

3/43/4

3/43/4

1/21/21/2

1/2

1/21/21/2

1/21/2

1/21/2

1/21/2

1/2

1/21/21/21/21/2

1/2

1/21/2

1/21/21/21/21/21/21/2

1/21/21/21/21/2

1/8

1/8

w/Vista

FASCIA MOUNT CONNECTION

Page 7: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

7

FASCIA MOUNT CONNECTION

HEADLOKSCREWS

Page 8: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

8

CONCRETE CONNECTION

GLASS PANELS

ALTERNATIVE CONNECTION:3/8” x 4” COBRA TORK CARBON STEEL ANCHOR-

42” R

ail H

eigh

t: 3

8.75

” • 3

6” R

ail H

eigh

t: 32

.75”

42” R

ail H

eigh

t: 33

.5” •

36”

Rai

l Hei

ght:

27.

5”

2.75”

2.5”

Tempering

Spec’d as per

Glass Panels

3.75”

deck / surface

6.5”

40”

Page 9: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

9

SPACERS

Your post/panel layout diagram may indicate the requirement of spacers at certain locations.

Spacers are used to make up small distances in the overall rail length in order for the railing to fit properly on the deck.

Shown at right is an example of how spacers are identified on a layout. Below it is a picture of how the spacer looks after installation.

InvisiRail spacers for stainless steel connectors come in 3/8” (10mm), 1/2” (13m), 3/4” (19mm) and 1” (25mm) sizes.

Spacers for lite 10 nylon connectors come in 1/4”, 3/8”, 1/2” and 3/4” sizes.

When referencing the on-centre chart to position your posts be sure to aDD the spacer dimension where indicated.

(2) x 1/2” indicates that one spacer must be installed behind the top connector and one

behind the bottom connector.

1” spacers

Page 10: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

10

GENERAL INFORMATION

Handrail brackets are installed between posts and glass connectors / angle brackets, replacing the backing plates packaged with the connectors.

Refer to post detail drawings to determine the type of handrail bracket required with each post.

HANDRAIL PIPE INSTALLATION

Install appropriate left / right brackets on all intermediate and end posts and corner brackets on all corner posts.

Remove the 1” bolt from the pivot and use the provided 1 1/2” bolt to connect the pivot to the bracket.

Carefully measure to determine the lengths of handrail required and cut your pipe to length using a pipe cutter or saw with a carbide-tipped metal cutting blade.

Joiners may be required for long spans requiring multiple lengths of pipe.

To maintain a seamless length with multiple pipe pieces use the “male” joiners at the un-cut pipe ends. Rough-cut pipe can be hidden with “female” joiners and/or in the “female” ends of the corner pivots.

Pre-drill pilot holes and secure pipe to inline brackets with tapping screws. 5/32” cobalt- tipped drill bit and screws are provided.

Secure pipe to corner brackets using set screws located on the underside of the pivot.

fixtures (joiners, pivots or domed ends) may be further secured to the pipe using provided glue.

STAINLESS STEEL HANDRAIL TOP MOUNT INSTALLATION

Corner pivot

male / female joiners

42mm (1 5/8”) diameter pipe with end cap

InvisiPost handrail bracket -- right hand side

JOIST

InvisiPost handrail bracket -- left hand side

JOIST

InvisiPost handrail bracket -- inside 90 cornero

JOIST

InvisiPost handrail bracket -- outside 90 cornero

JOIST

Use right hand bracket for middle post or left end post

Use left hand bracket for middle post or right end post

Right hand bracket

Left hand bracket

InvisiPost Handrail Brackets

Corner bracket

Variable bracket for non90-degree angles

Use short corner bracket for outside 90-degree corners

Use long corner bracket for inside 90-degree corners

Page 11: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

11

InvisiPost with short corner bracket and pivot on outside 90-degree corner InvisiPost with long corner bracket and pivot on

inside 90-degree corner

Square post with ALX corner bracket and pivot on outside 90-degree corner

Square post with ALX left and right brackets and pivot on inside 90-degree corner

Square posts on non 90-degree split angles can use left/right top rail brackets (shown at left) or a flange-

mount handrail bracket (shown above)

Transitioning from top rail to stair rail is accomplished with two pivots connected with

a male joiner or short piece of rail pipe.Optionally, you may terminate the top rail with

an end cap then install separate stair rail at the desired height.

NO representation is given that your particular application of these products complies with relevant building codes. All products installed without a top rail DO NOT comply with the USA IRC test report provided by Intertek. Therefore, consult with professionals AND local building officials before starting to ensure compliance in your area. The consumer or contrac-tor should take all necessary steps to ensure the safety of all involved in installation of the project, including, but not limited to use of safety glasses, work gloves and safety shoes. NO member of Liv Building Products, or Invisirail shall be liable for any loss, damage or personal injury due to the improper installation of products, or failure to use all items as per the USA-IRC test report . IN the unlikely event of any loss, damage or injury, the total aggregate liabilities will be limited to the retail purchase price of the products.

Page 12: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

GENERAL INFORMATION

Only install the outer half of connectors to posts. The remaining half gets installed with glass panel.

Glass panels come with two top holes and two bottom notches. Four connector pins should be installed to secure glass to posts (minimum 1 per side must be used.)

Each connector uses a 1/16” backing plate.

InvisiPost: Connector to Connector

Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.

Put the bolt through the connector, backing plate (provided in connector packs), post, back-ing plate and connector. Thread the bolt through the nut on the other side of the connector.

Make sure that connectors are perfectly vertical!

InvisiPost: Connector to Universal Angle Bracket

Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.

STAINLESS STEEL GLASS CONNECTOR INSTALLATION

5/16” X1 1/2” bolt

5/16” X 1” bolt

connector pin

Disassemble prior to installation

12

Page 13: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

Put the bolt through the connector, backing plate (provided in connector packs), post and thread into Universal angle Bracket on the other side.

InvisiPost: Universal Angle Bracketto Universal Angle Bracket

Disassemble the brackets by taking out the lock-ing pin and hinge screw.

Make sure you have both a threaded and a non-threaded Universal angle Bracket.

Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.

Put the bolt through the non-threaded bracket, post and thread into Universal angle Bracket on the other side.

InvisiPost: End post with Connector

Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use the Bolt Chart to determine the size you need for the application. Refer to your post layout diagram to see if you must add spacers.

Put the bolt through the connector, backing plate, post and into the acorn nut provided..

5/16” X 1” bolt

5/32” or 4mmhex key

5/16” X 1” bolt

13

Page 14: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

InvisiPost: End post with Universal Angle Bracket (UAB)

Top bracket to be installed in predrilled hole 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Connector to UAB: Thread a 5/16” X 1/2” bolt through the connector into the swivel por-tion of the bracket until tight.

UAB to Post: Thread a 5/16” X 1” bolt through bracket, post and into the acorn nut provided.

VISTA (ALUMINUM) POST ANDWOOD POST CONNECTOR INSTALLATION

If using VISTA posts, Aluminium posts, 4” x 4” wood posts, or 6” x 6” wood posts, refer to the INVISIRAIL BOLT CHART. Check your post layout diagram to see if you must add spacers.

Straight-Run Connector

Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use InvisiRail Template to locate exactly where connectors should go.

Use hardware provided to attach connector to post (stainless self-tapping lags for aluminum posts or wood screws for wood posts.)

Do not over-tighten lags, causing stripping.

Re-assemble bracket using 5/32” or 4mm

hex key

Bottom position forstainless connectors

Middle hole position for bottom Lite 10 connectors

Template for positioning connectors on VISTA posts & square aluminum or wood posts

For wood posts flip template upside down and place at

base of post on deck surface.

Top position for stainless steel connectors or middle hole position for top Lite 10connectors

14

Page 15: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

Universal Angle Bracket

Disassemble the brackets by taking out the locking pin and hinge screw.

Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.)

Use InvisiRail Template to locate exactly where connectors should go.

Use hardware provided to attach Universal angle Bracket to post (stainless self-tapping lags for Vista/aluminum posts or wood screws for wood posts.)

Once the hinge is fastened to the post, reassemble bracket and attach glass connector.

15

Invisirail with 1 5/8” diameter stainless steel top rail is International Residency Code (IRC) compliant

White Vista posts with Lite 10 connectors

Page 16: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

LITE 10 NYLON GLASS CONNECTOR INSTALLATIONLite 10 connectors are for use with Vista (aluminum) and wood posts. They are not designed for use with InvisiPosts.

Top bracket to be installed 40 inches O/C above deck surface for 42 inch rail height (34 inches for 36 inch rail height.) Use InvisiRail Template to locate exactly where connectors should go.

Disassemble the top connector by backing out the nylon retaining pin and sliding off the splined part.

Use hardware provided to attach connector to post (stainless self-tapping screws for Vista / aluminum posts or wood screws for wood posts.) Do not over-tighten tapping screws, causing stripping.

ensure connectors are as parallel as possible to the edge of the post.

Install the open side of the top connector facing towards deck for easier glass installation.

45 degreeanglebracketwith connector

Lite 10 Angle Bracket

Use InvisiRail Template to locate exactly where angle brackets should go.

Mark the bottom edge location of both top and bottom connectors. Bottom mark should be 3 1/4” above flange base. Top mark should be 38 15/16” above flange base.

fasten the 45 degree adaptor to the post with the mark at the bottom of the 45 degree adap-tor.

Using #8 x 1” wood screws (not included) screw the lite 10 connector to the 45 degree angle adaptor.

Mark for angle brackets

16

Page 17: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

Stainless Steel Connectors

Use two short pieces of 2X4’s or 4X4’s, sitting on edge of the deck between the posts, to support the glass panels while installing.

Door shims help with fine height adjustments. Connector pins need to be aligned with holes/notches in the glass.

locate correct glass panel to be installed (all panels are labeled.)

Carefully pick up panel and set into position with notches in glass at the bottom.

fasten top connectors first. Place pin through glass and slide remaining connector half into position. If required, shim panel until pin is positioned horizontally, aiding in alignment of connector halves.

Tighten screws enough to hold connectors together but not squeeze tightly on glass.

Once completed, check that all connectors are parallel to each other and tighten screws completely.

GLASS PANEL INSTALLATION

Lite 10 Nylon Connectors

locate correct glass panel to be installed (all panels are labeled.)

Carefully pick up panel and set into position above bottom connectors (notches in glass should be at the bottom) and push glass down into connector until it bottoms.

Take top connector half and slide it into position, then screw pin back in.

If pin does not screw in easily make sure there are no alignment issues. Possible sources of error are: out of plumb posts, posts not set at correct dimension, deck surface not level, connectors not located correctly.

If the connector halves do not slide easily onto installed sections, confirm that the connector has not been over tightened - this would cause misalignment of the two halves.

The back half of connector must be completely flush with the front half to ensure the pin is in the holes in both halves of the connector.

Once the pin is perfectly aligned, completely tighten screws.

17

Page 18: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

STAIR GLASS and CUSTOM GLASS Stair Glass

Stair glass for InvisiRail is always custom cut and takes 3-4 weeks for production.

Each piece of stair glass will require a template.

Please ensure accuracy as your glass will be made to the exact size/shape of your template.

Install posts in positions indicated on your post/panel layout diagram, ensuring that they are completely plumb.

(TIP: Use 2” wood screws with washers when locating the stair posts for templating. When glass panels come back you can easily mi-cro-adjust post positions to accommodate glass connection. Once stair glass is installed, switch out the 2” wood screws one by one with the supplied gRKs.)

attach glass connectors to your posts.

Custom Horizontal Glass

Set posts in desired locations, ensuring that they are completely plumb.

Measure from inside post to inside post.

If there are any angled sections, the angle bracket must be installed and measurement must be taken from the face of the angle bracket.

On your order it must be indicated if the measurement was taken from inside posts or face of angle bracket anD the type of glass connectors used (stainless steel or lite 10.)

Use the Custom glass Order form at the back of this manual to complete your order.

Use the InvisiRail cardboard template/s provided to make a template of the exact size and shape of the glass desired.

Install the template into glass connectors and trace around all four (4) connectors for hole and pin location. Indicate the top/bottom orientation and write your name and return shipping address on each template.

Please include the store name and Invoice Order number (or Purchase Order or Estimate Number, if possible) with your templates.

Customer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Phone number: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

InvisiRail dealer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shipping address for glass: .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .fax form to 905-852-5196 or email to [email protected]

18

Page 19: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

InvisiPost -- beside stairs scale 1:1

JOIST

3 1/4” toglass

2” to centre post 1 1/4” to glass

STAIRS

3/8”

11/16” (0.6875”)

INVISIPOST POSITIONING DETAIL DIAGRAMS

RIM JOIST

HOUSEHEADERorENDJOIST

1 5/8” MIN - 3 3/4 MAX to centre post

3 1/4” toglass

3/8”

InvisiPost at house or end of run scale 1:1

3/8” MIN - 2 1/2 MAX to flange

InvisiPost -- inside 90 scale 1:1o

JOIST 2 1/2” to anglebracketor2 5/8”(2.625”) toequivalentcentre post

3 1/4” to glass3 1/4” to glass

1 7/8” to centre post 1 3/8” to glass

3/8”

JOIST

5/8”

1 11/16”(1.6875”)

InvisiPost -- outside 90 scale 1:1o

RIM JOIST

ENDJOIST

3 7/8” toequivalenton centreOR4” toanglebracket

4 9/16” (4.5625”) to centre post

3 1/4” toglass

3 1/4” to glass

3/8”

3 5/16” (3.3125”) to flange base

4 3/8” to post face

19

FASCIA

InvisiPost -- inside 45 split scale 1:1o

3 1/4” to glass

7/16” (0.4375“) to angle bracket or

5/16” (0.3125”) to centre post equivalent

JOIST

3 1/4” to glass

1/8”

FASCIA

InvisiPost -- inside 45 split scale 1:1o

3 1/4” to glass

7/16” (0.4375“) to angle bracket or

5/16” (0.3125”) to centre post equivalent

JOIST

3 1/4” to glass

1/8”

Page 20: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

InvisiPost -- inside 45 scale 1:1o

JOIST

3 1/4” to glass

3/8”

3 1/4” to glass

ONCENTRE

5/8”or 3/4” tocentre post equivalent

InvisiPost -- outside 45 scale 1:1o

2 5/8” tocentre post

2” to centre post equivalent

3 1/4” to glass

3/8”

JOIST

3 1/4” to glass

1 3/8”toflangebase

2 7/16”(2.4375”)to postface

2 1/8” to angle bracket

FASCIA

InvisiPost -- inside 90 split scale 1:1o

3 1/4” to glass

JOIST

3 1/4” to glass

3/8”

5/8” to angle bracketor

3/4” to centre post equivalent

5/8” to angle bracket

or3/4” to centre post equivalent

InvisiPost -- outside 90 split scale 1:1o

FASCIA

JOIST

3 1/4” toglass

3 1/4” to glass

1 7/16”

1 7/16”

3 1/16”

5 7/8”to angle bracket or 5 3/4” to centre post equivalent

20

Page 21: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

FASCIA

InvisiPost -- inside 45 split scale 1:1o

3 1/4” to glass

7/16” (0.4375“) to angle bracket or

5/16” (0.3125”) to centre post equivalent

JOIST

3 1/4” to glass

1/8”

InvisiPost -- outside 45 split scale 1:1o

1 1/8”

3 1/2” to angle bracketor

3 3/8” to centre post equivalent

JOIST3 1/4” to glass

3 1/4” to glass

InvisiPost -- outside 22.5 split scale 1:1o

3/4”

RIMJOIST

3 1/4” to glass

2 3/4” to angle bracketor

2 5/8” to centre post equivalent

3 1/4” to glass

InvisiPost -- inside 22.5 split scale 1:1o

3/16” RIMJOIST

3 1/4” to glass

1 7/16” (1.4375”) to angle bracketor

1 5/16” (1.3125”) to centre post equivalent

3 1/4” to glass

21

Page 22: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

15/32”

7/16”

7/16”

2 1/2”

4 3/4”

1 7/8”

InvisiPost flange base scale 1:1

22

Page 23: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

23

ALX post at house or end of run scale 1:1

JOIST

HOUSEHEADEROR ENDJOIST

5 1/8” MAX - 2 3/4” MIN to centre post

1/4” min.

1/4” MIN - 2 5/8” MAX to flange

2 3/4” toglass

JOIST

ALX Post -- outside 45 SPLIT scale 1:1o

2 3/4” to glass

7/16”

2 3/4” to glass

4 3/8” to angle bracket 3 1/8” to centre post equivalent

7/16”

1 3/8”

ALX Post -- outside 22.5 SPLIT scale 1:1o

3 3/4” to anglebracketOR2 1/2” toequivalenton centrepost

3 1/4” to glass

1 3/16”

JOIST3 1/4” to glass

3/4”

3/4”

ALX post -- inside 45 SPLIT scale 1:1o

JOIST

3 1/4” to glass

1 15/16” (1.9375“)to angle bracket

11/16” (.6875”) to centre post equivalent

1/8”

3 1/4” to glass

ALX Post -- inside 22.5 SPLIT scale 1:1o

JOIST

3 1/4” to glass

2 1/2” to angle bracket1 1/4” to centre post equivalent

3/8”

3 1/4” to glass

ALX Post -- inside 22.5 SPLIT scale 1:1o

JOIST

3 1/4” to glass

2 1/2” to angle bracket1 1/4” to centre post equivalent

3/8”

3 1/4” to glass

Page 24: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

24

5”

5”

2 1/2”

2 1/2”

21/32”

21/32”

11/32”

ALX post flange base scale 1:1

Page 25: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

25

VistaPost -- beside stairs scale 1:1

2 1/2 ” to centre post

STAIRS

JOIST

1 3/8 ”

2 1/2 ” tocentre post

1 3/8 ”

VISTA POST POSITIONING DETAIL DIAGRAMS

VistaPost at house or end of run scale 1:1

JOIST

HOUSEHEADEROR ENDJOIST

4 7/8” MAX - 2 5/8” MIN to centre post

3/8”

3/8” MIN - 2 5/8” MAX to flange

Vista Post -- inside 90 scale 1:1o

JOIST

2 1/2” to glass

1 3/8” to post face

JOIST

1/4”

2 1/2” to glass

1 3/8” to post face

Vista Post -- inside 90 scale 1:1o

JOIST

2 1/2” to glass

1 3/8” to post face

JOIST

1/4”

2 1/2” to glass

1 3/8” to post face

1 1/2”

VistaPost -- outside 90 scale 1:1o

JOIST

JOIST

1 1/2

2 5/8” to centre post

3/8”

3/8”

Page 26: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

VistaPost -- inside 45 scale 1:1o

JOIST

2 1/2” to glass

1 1/4” to centre post

1/4”

2 1/2” to glass

5/16” (0.3125”)

w/stainless steel connectors

1/8”

or 1 7/16”(1.4375”) forcentre postequivalent

1 13/16” (1.8125”) to angle bracket

or 11/16” (0.6875”) tocentre post equivalent

2 1/2” to glass

1/4”

JOIST

2 1/2” to glass

3 1/4” tocentrepost

1”

VistaPost -- outside 45 scale 1:1o

w/stainless steel connectors

2 1/8”

VistaPost -- inside 45 scale 1:1o

JOIST

2 1/2” to glass

1 9/16”(1.5625”) toouter face

1/4” 2 1/2” to glass

5/8”(0.625”)

w/ Lite 10 connectors

7/16” (0.4375”) tocentre post

or 1 3/4”(1.75”) for

centre postequivalent

1 3/8” (1.375”) to angle bracket

or 1/4” (0.25”) to centre post equivalent

2 1/2” to glass

1/4”

JOIST

2 1/2” to glass

2 1/2” tocentrepost

1/4”

VistaPost -- outside 45 scale 1:1o

w/Lite 10 connectors

1 3/8”(1.375”)

26

Page 27: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

FASCIA

InvisiPost -- inside 45 split scale 1:1o

2 1/8” to angle bracket or

1” to centre post equivalent

JOIST

2 1/2” to glass

2 1/2” to glass

FASCIA

InvisiPost -- inside 45 split scale 1:1o

3/4” to angle bracket or ADD

3/8” to centre post equivalent

JOIST

2 1/2” to glass

2 1/2” to glass

Lite 10 connectors

4 1/4” to anglebracket

1 3/8”

1/2”

JOIST

2 1/2” to glass

VistaPost -- outside 45 split scale 1:1o

4 1/4” to angle bracket or 3 1/8” to centre post equivalent

2 1/2” to glass

1/2”

Stainless steel connectors

FASCIA

InvisiPost -- inside 45 split scale 1:1o

3/4” to angle bracket or ADD

3/8” to centre post equivalent

JOIST

2 1/2” to glass

2 1/2” to glass

Lite 10 connectors

FASCIA

InvisiPost -- inside 45 split scale 1:1o

2 1/8” to angle bracket or

1” to centre post equivalent

JOIST

2 1/2” to glass

2 1/2” to glass

1”

JOIST

2 1/2” to glass

VistaPost -- outside 45 split scale 1:1Lite 10 connectors

o

2 13/16” (2.8125“) to angle bracket or 1 11/16” (1.6875”) to centre post equivalent

2 1/2” to glass

4 1/4” to anglebracket

1 3/8”

1/2”

JOIST

2 1/2” to glass

VistaPost -- outside 45 split scale 1:1o

4 1/4” to angle bracket or 3 1/8” to centre post equivalent

2 1/2” to glass

1/2”

Stainless steel connectors

27

Page 28: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

1/2”

4 1/2”

4 1/2”

7/16”

1/2”

2 1/4”

2 1/4”

15/32”

7/16”

7/16”

2 1/2”

4 3/4”

1 7/8”

InvisiPost flange base scale 1:1

15/32”

7/16”

7/16”

2 1/2”

4 3/4”

1 7/8”

InvisiPost flange base scale 1:1

Vista Post flange base scale 1:1

28

Page 29: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

INVISIPOST FASCIA POSITIONING DETAIL DIAGRAMS

11/16” (0.667”) to angle bracketor

9/16” (0.5625”) to centre post equivalent

fascia-mount InvisiPost - corner scale 1:1

FASCIA

2” to glass

fascia-mount InvisiPost inside 90 scale 1:1

2” toglass

2 3/4” to angle bracket or2 5/8 to centre post equivalent

o

FASCIA

2” to glass

3 1/4” tocentre post

3 1/8” toface of post

2” toflange

2 X 1” spacersbetweenpost andanglebracket

1 1/4” toangle bracketor 1 3/8” tocentre postequivalent

2” toglass

o

FASCIA

2” to glass

1 1/4” tocentre post

1 1/8” topostface

fascia-mount InvisiPost outside 90 scale 1:1 fascia-mount InvisiPost -- inside 45 scale 1:1

o

1 1/2” toangle bracket

or1 3/8” to centre post

equivalent

2” toglass

2 1/8” to centre post

FASCIA

2” toglass

7/8” toflange

29

Page 30: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

1/8” to angle bracket or

1/4” to centre post equivalent

fascia-mount InvisiPost -- outside 45 scale 1:1o

2” toglass

1 1/2” to centre post

FASCIA

1/4” toflange

1” spacer betweenpost and angle bracket

2” toglass

1.35”

fascia-mount InvisiPost -- beside stairs scale 1:1

2 3/4” to anglebracket or2 5/8” to

centre post equivalent

2” toglass

3 1/4 ” to centre post

STAIRS

FASCIA

2” to glass

2” to flange

3 1/8” to face of post

30

Page 31: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

VISTA POST FASCIA POSITIONING DETAIL DIAGRAMS

1 5/16”(1.3125”)

to face of post

VistaPostfascia-mount corner scale 1:1

FASCIA

1 5/16”(1.3125”)

to face of post

2 7/16”(2.4375”)to centre

post

VistaPost fascia -- inside 90 scale 1:1o

2 3/8” to glass

JOIST

2 3/8” to glass

RIM JOIST

VistaPost fascia-mount outside 45 corner scale 1:1

o

2 7/16”(2.4375”) to centre

post

31

Page 32: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

VistaPost fascia -- inside 45 scale 1:1o

1 5/8” to angle bracket2 3/8”

to glass

JOIST

7/8”

w/stainless steel connectors

2 3/8” to glass

3 3/8” to centre post

1 1/2” to equivalent on centre

VistaPost fascia -- inside 45 scale 1:1o

1 5/16” (1.3125”) to angle bracket2 3/8”

to glass

JOIST

w/Lite 10 connectors

2 3/8” to glass

2 1/2” to centre post

3/16” (0.1875”) to equivalent on centre

32

Page 33: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

33

Customer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Phone number: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

InvisiRail dealer name: ..... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shipping address for glass: .... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

fax form to 905-852-5196 or email to [email protected]

Page 34: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

34

Page 35: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART
Page 36: INSTALLATION MANUAL - invisirail.cominvisirail.com/wp-content/uploads/2018/04/InvisiRail_Manual_V2-1.pdf · INSTALLATION MANUAL . 4 PRE-INSTALLATION REQUIREMENTS 4 BOLT SIZE CHART

w w w. inv i s i ra i l . com sa les@inv is i ra i l . com To l l f ree 1-888-681-9733

Any ins ta l la t ion or use of the p roduct must be in accordance wi th a l l loca l zon ing and/or bu i ld ing codes . The consumer assumes a l l r i sk and l i ab i l i ty assoc ia ted wi th the ins ta l la t ion or use of th i s p roduct .

Check wi th loca l munic ipa l i t ies fo r bu i ld ing code requ i rement in your a rea be fore ins ta l l ing .


Recommended