  • PTD-RGDELI/MEAT/SEAFOOD

    06/18

    MULTI-DECK MERCHANDISERI N S TA L L AT I O N & O P E R AT I O N S M A N UA L

    Energy Data & Case Dimensions .......................2-4

    General Information ............................................... 5

    Installation ..........................................................6-7

    Case Connections ...............................................8-9

    Lighting and Power Supplies ......................... 10-11

    Pre-Power Checklist ............................................12

    Airfl ow & Defrost ..................................................13

    Case Cleaning ................................................ 14-15

    Parts Ordering ......................................................16

    Table of Contents

    To ensure proper functionality and optimum performance, it is STRONGLY recommended that Hillphoenix specialty cases be installed/serviced by qualifi ed tech-

    nicians who have experience working with commercial refrigerated display merchandisers and storage cabinets. For a list of Hillphoenix-authorized installation/

    service contractors, please visit our website at www.hillphoenix.com.

  • ii

  • LIABILITY NOTICE

    For Cases with Shelf Lighting Systems

    Hillphoenix does NOT design any of its shelf lighting systems or any of its display cases with shelf lighting

    systems for direct or indirect exposure to water or other liquids. The use of a misting system or water hose

    on a display case with a shelf lighting system, resulting in the direct or indirect exposure of the lighting

    system to water, can lead to a number of serious issues (including, without limitation, electrical failures,

    fi re, electric shock, and mold) in turn resulting in personal injury, death, sickness, and/or serious property

    damage (including, without limitation, to the display itself, to the location where the display is situated

    [e.g., store] and to any surrounding property). DO NOT use misting systems, water hoses or other devices

    that spray liquids in Hillphoenix display cases with lighted shelves.

    If a misting system or water hose is installed or used on a display case with a shelf lighting system, then

    Hillphoenix shall not be subject to any obligations or liabilities (whether arising out of breach of contract,

    warranty, tort [including negligence], strict liability or other theories of law) directly or indirectly resulting

    from, arising out of or related to such installation or use, including, without limitation, any personal injury,

    death or property damage resulting from an electrical failure, fi re, electric shock, or mold.

    P079211M, REVO

    R-744 (CO2) NOTICE

    For Systems Utilizing R-744 (CO2) Refrigerant

    For refrigeration units that utilize R-744 (CO2), pressure relief and pressure-regulating relief valves may need

    to be installed based on the system capacity. The valves need to be located such that no stop valve is posi-

    tioned between the relief valves and the parts or section of the system being protected.

    When de-energizing refrigeration units containing R-744 (CO2), venting of the R-744 (CO2) refrigerant may

    occur through the pressure regulating relief valves. These valves are located on the refrigeration system

    and not on the case model. If venting does occur, the valve must not be defeated, capped, or altered by any

    means.

    WARNING: Under no circumstances should any component be replaced or added without consulting Hill-

    phoenix Field Service Engineering. Utilizing improper components may result in serious injury to persons

    or damage to the system.

    iii

  • Important

    D A N G E R Indicates an immediate threat of death or seri-ous injury if all instructions are not followed carefully.

    At Hillphoenix, the safety of our customers and employees, as well as the ongo-ing performance of our products, are top priorities. To that end, we include impor-

    tant warning messages in all Hillphoenix installation and operations handbooks,

    accompanied by an alert symbol paired with the word "DANGER", "WARNING", or

    "CAUTION".

    All warning messages will inform you of the potential hazard; how to reduce the

    risk of case damage, personal injury or death; and what may happen if the in-

    structions are not properly followed.

    W A R N I N G

    Indicates a potential threat of death or serious injury if all instructions are not followed care-fully.

    C A U T I O N

    Indicates that failure to properly follow instruc-tions may result in case damage.

    iv

  • Revision History

    new manual format_06/18

    v

  • ENERGY DATA

    Numbers are based on standard case sizes. Consult engineering.

    Electrical Data (Dome)

    PTD REMOTE BASE & REMOTE GRAVITY DOME

    All measurements are taken per ASHRAE - 72 - 2005 specifications.

    Hillphoenix refrigerated display cases for sale in the United States meet or exceed

    department of energy 2017 efficiency requirements.

    Engineered for stores with ambient conditions not to exceed 75o and 55% relative humidity.

    Due to engineering improvements specifications may change without notice.

    Model

    Fans per

    Case

    Box FansHigh Effi ciency

    FansAnti-Condensate

    FansDrain

    HeatersOptional Defrost

    Heaters

    120 Volts 120 Volts 120 Volts 120 Volts 208 Volts

    Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts

    PTD-RG 4 1 0.13 15.6 - - -1 - - - 0.17 20.4 - - - - - - - - - - - -

    6 2 0.26 31.2 - - - - - - 0.31 37.2 - - - - - - - - - - - -

    8 3 0.39 46.8 - - - - - - 0.42 50.4 - - - - - - - - - - - -

    10 4 0.52 62.4 - - - - - - 0.52 62.4 - - - - - - - - - - - -

    12 4 0.52 62.4 - - - - - - 0.62 74.4 - - - - - - - - - - - -

    Model

    Fans per

    Case

    High Effi ciencyFans

    Anti-CondensateFans

    DrainHeaters

    Optional DefrostHeaters

    RRS2

    Fansper

    Case

    Unit Cooler Fans

    120 Volts 120 Volts 120 Volts 208 Volts 120 Volts

    Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts

    PTD-RG 4 1 0.3 36 - - - - - - - - - - - - - - - - - - - - - - - - - - -

    6 2 0.6 72 - - - - - - - - - - - - - - - - - - - - - - - - - - -

    8 3 0.9 108 - - - - - - - - - - - - - - - - - - - - - - - - - - -

    10 4 1.2 144 - - - - - - - - - - - - - - - - - - - - - - - - - - -

    12 4 1.2 144 - - - - - - - - - - - - - - - - - - - - - - - - - - -

    Electrical Data (Base)

    Lighting Data

    Guidelines & Control Settings (DX)

    ModelConventional

    3BTUH/ftParallel

    4BTUH/ft

    SuperheatSet Point @ Bulb

    (oF)Evaporator

    (oF)

    Discharge Air(oF)

    Discharge Air5

    Velocity(FPM)

    PTD-RG Dome 330 300 6-8 15 28 - - -

    Base 485 445 6-8 26 29 250

    RRS 109 100 10 26 29 200

    Model

    Lights

    per

    Row

    Light

    Length

    (ft)

    Clearvoyant 4 LED Lighting(Per Light Row)

    Standard Power(Cornice or Shelf)

    High Power(Cornice)

    120 Volts 120 Volts

    Amps Watts Amps Watts

    PTD-RG 4 1 4 0.05 5.9 0.12 14.9

    6 2 3 0.08 9.4 0.20 23.8

    8 2 4 0.10 11.8 0.24 29.8

    10 2 5 0.12 15.0 0.30 37.0

    12 3 4 0.15 17.7 0.36 44.7

    2

  • ENERGY DATA

    Defrost Controls

    PTD REMOTE BASE & REMOTE GRAVITY DOME

    Numbers are based on standard case sizes. Consult engineering.

    All measurements are taken per ASHRAE - 72 - 2005 specifications.

    Hillphoenix refrigerated display cases for sale in the United States meet or exceed

    department of energy 2017 efficiency requirements.

    Engineered for stores with ambient conditions not to exceed 75o and 55% relative humidity.

    Due to engineering improvements specifications may change without notice.

    1 NOTE: - - - indicates data not applicable.

    2 RRS - Refrigerated Rear Storage.

    3,4 Listed BTUH indicates unlighted shelves. Add the following for lighted shelves:

    4 Shelf LED: 36 BTUH

    4 Canopy LED: 72 BTUH

    3 Shelf LED: 27 BTUH

    3 Hi-Output LED: 54 BTUH

    5 Average discharge air velocity at peak of defrost.

    6,7 Time-off duration for defrost with no termination control.

    ModelDefrostsper Day

    Run-OffTime (min)

    Electric Defrost Timed-Off Defrost Hot Gas Defrost

    Fail-Safe (min)

    TerminationTemp (oF)

    Fail-Safe (min)

    TerminationTemp (oF)

    Fail-Safe (min)

    TerminationTemp (oF)

    PTD-RG Dome 1 - - - - - - - - - 90/60 47 - - - - - -

    Base 4 - - - - - - - - - 65/636 42 - - - - - -

    RRS 4 - - - - - - - - - 65/736 42 - - - - - -

    3

  • CASE DIMENSIONS

    51 in [129.5 cm]

    POWER SUPPLY

    42 in [106.7 cm]

    97 in121 in145 in

    72 1/2 in48 1/2 in[123.2 cm] {4 case}

    [184.2 cm] {6 case}[246.4 cm] {8 case}[307.3 cm] {10 case}[368.3 cm] {12 case}

    2 in [5.2 cm]

    6 in [15.2 cm]

    12 in [30.5 cm]

    18 in [45.7 cm]

    51 in [129.5 cm]

    1 in [2.5 cm]

    1 in [2.5 cm]

    TOEKICK

    TOEKICK15" x 11" MECHANICAL ACCESSFOR ELECT. ,REFRIG. ,AND DRAIN CONNECTIONS

    LCFRONT OF CASE

    11 13/16 in

    [30.0 cm]

    16 7/16 in

    [41.8 cm]22 3/4 in

    [57.8 cm]

    LOAD LIMIT LINE

    6 5/16 in

    [16.1 cm]

    16 3/4 in

    [42.5 cm]

    13 5/8 in

    [34.6 cm]

    42 in

    [106.7 cm]

    1 1/2 in

    [3.7 cm]

    12 in

    [30.5 cm]

    ELECTRICAL RACEWAY

    LOWER REAR STORAGE

    WITH DOORS

    REAR SLIDING DOORS

    33 5/16 in

    [84.6 cm]

    19 9/16 in

    [49.7 cm]

    SLIDING

    REAR

Click here to load reader

Reader Image
Embed Size (px)