User Manual Installation Industrial Cellular Router OWL-IPG-AMERICAS Installation OWL IPG Release 01, 01/2020 Technical Support https://hirschmann-support.belden.com
Transcript
Page 1: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

User Manual

InstallationIndustrial Cellular RouterOWL-IPG-AMERICAS

Installation OWL IPGRelease 01, 01/2020

Technical Supporthttps://hirschmann-support.belden.com

Page 2: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

The naming of copyrighted trademarks in this manual, even when not specially indicated, should not be taken tomean that these names may be considered as free in the sense of the trademark and tradename protection lawand hence that they may be freely used by anyone.

© 2020 Hirschmann Automation and Control GmbH

Manuals and software are protected by copyright. All rights reserved. The copying, reproduction, translation, con-version into any electronic medium or machine scannable form is not permitted, either in whole or in part. Anexception is the preparation of a backup copy of the software for your own use.

The performance features described here are binding only if they have been expressly agreed when the contractwas made. This document was produced by Hirschmann Automation and Control GmbH according to the best ofthe company's knowledge. Hirschmann reserves the right to change the contents of this document without priornotice. Hirschmann can give no guarantee in respect of the correctness or accuracy of the information in this doc-ument.

Hirschmann can accept no responsibility for damages, resulting from the use of the network components or theassociated operating software. In addition, we refer to the conditions of use specified in the license contract.

You can get the latest version of this manual on the Internet at the Hirschmann product site(http://www.hirschmann.com).

Hirschmann Automation and Control GmbHStuttgarter Str. 45-5172654 NeckartenzlingenGermany

2 Installation OWL IPGRelease 01, 01/2020

Page 3: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

Contents1 Safety Instructions 42 About This Manual 83 Start Here 93.1 About the OWL-IPG-AMERICAS Industrial Cellular Gateway 93.1.1 Specifications 10

3.2 Package Contents 113.3 Jumpers 113.4 Reset (Power Cycle) Button 12

4 Hardware Installation 134.1 Power Requirements 134.2 Antenna Installation 154.3 Connecting the Radio to a Network Device 164.3.1 Ethernet Cable Specifications 174.3.2 Serial Port Basics 18

4.4 LED Indicators 195 Connecting to the OWL-IPG-AMERICAS 215.1 ConfigurationWebpage Setup 215.2 Assigning a LAN IP Address 235.3 Connecting to Your Cellular Provider 265.3.1 Connection UsingGSM/GPRS 265.3.2 Connection Using CDMA 285.3.3 SIMCard Security 285.3.4 SIMCard PIN Verification 295.3.5 Unblocking a SIMCard 31

5.4 Connecting to the Internet Using theOWL-IPG-AMERICAS 346 Further Support 35

3Installation OWL IPGRelease 01, 01/2020

Page 4: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

1 Safety InstructionsWARNING

UNCONTROLLED MACHINE ACTIONS

To avoid uncontrolled machine actions caused by data loss, configure all the data transmission devices indi-vidually.

Before you start any machine which is controlled via data transmission, be sure to complete the configuration ofall the data transmission devices.

Failure to follow these instructions can result in death, serious injury, or equipment damage.

General safety instructions

You operate this device with electricity. Improper usage of the device entails the risk of physical injury or sig-nificant property damage. The proper and safe operation of this device depends on proper handling during trans-portation, proper storage and installation, and careful operation and maintenance procedures.

l Before connecting any cable, read this document, and the safety instructions and warnings.

l Operate the device with undamaged components exclusively.

l The device is free of any service components. In case of a damaged or malfunctioning device, turn off thesupply voltage and return the device to Hirschmann for inspection.

Certified usage

l Use the product only for the application cases described in the Hirschmann product information, includ-ing this manual.

l Operate the product only according to the technical specifications. See the Specifications section.

l Connect to the product only components suitable for the requirements of the specific application case.

Installation site requirements

l When you are selecting the installation location, make sure you observe the climatic threshold valuesspecified in the technical data.

l Operate the device at the specified ambient temperature (temperature of the ambient air at a distance of2 in (5 cm)).

l Use the device in an environment with a maximum pollution degree that complies with the specificationsin the technical data.

4 Installation OWL IPGRelease 01, 01/2020

Page 5: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

Device casing

Only technicians authorized by the manufacturer are permitted to open the casing.

l Never insert sharp objects (narrow screwdrivers, wires, etc.) into the contacts for electric conductors anddo not touch the contacts.

Qualification requirements for personnel

Only allow qualified personnel to work on the device.

Qualified personnel have the following characteristics:

l Qualified personnel are properly trained. Training as well as practical knowledge and experience makeup their qualifications. This is the prerequisite for grounding and labeling circuits, devices, and systems inaccordance with current standards in safety technology.

l Qualified personnel are aware of the dangers that exist in their work.

l Qualified personnel are familiar with appropriate measures against these hazards in order to reduce therisk for themselves and others.

l Qualified personnel receive training on a regular basis.

National and international safety regulations

l Verify that the electrical installation meets local or nationally applicable safety regulations.

l When installing antennas, observe the regulations of the country in which you are operating the WLANdevice with regard to the general operating permission and the maximum emission levels.

l Install and operate this equipment with a minimum distance of 7.9 in (20 cm) between the antenna andyour body.

Recycling note

After usage, this device must be disposed of properly as electronic waste, in accordance with the current dis-posal regulations of your county, state, and country.

Grounding the device

The device is grounded via the power supply connection.

Shielding ground

The shielding ground of the connectable twisted pair cable is connected to the grounding connector as a con-ductor.

l Beware of possible short circuits when connecting a cable section with conductive shielding braiding.

5Installation OWL IPGRelease 01, 01/2020

Page 6: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

Installation Instructions:

THIS EQUIPMENT IS AN OPEN-TYPE DEVICE AND IS MEANT TO BE INSTALLED IN AN ENCLOSURESUITABLE FOR THE ENVIRONMENT SUCH THAT THE EQUIPMENT IS ONLY ACCESSIBLE WITH THE USEOF A TOOL.

SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D HAZARDOUS LOCATIONS, ORNONHAZARDOUS LOCATIONS ONLY.

WARNING – EXPLOSION HAZARD – DO NOT DISCONNECT EQUIPMENTWHILE THE CIRCUIT IS LIVE ORUNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.

WARNING – EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTMAY IMPAIR SUITABILITY FORCLASS I, DIVISION 2.

INSTRUCTIONS D'INSTALLATION:

CET APPAREIL EST UN DISPOSITIF DE TYPE OUVERT ET EST DESTINÉ A ETRE INSTALLÉ DANS UNENVIRONNEMENT ADAPTÉ AFIN QUE L'ÉQUIPEMENT SOIT ACCESSIBLE UNIQUEMENT AVECL'UTILISATION D'UN OUTIL.

ADAPTÉ POUR UNE UTILISATION EN CLASSE I, DIVISION 2, GROUPES A, B, C ET ZONES DANGEREUSESOU NON.

AVERTISSEMENT - RISQUE D'EXPLOSION - NE PAS DÉCONNECTER L’ÉQUIPEMENT LORSQUE LECIRCUIT EST EN FONCTIONNEMENT A MOINS QUE LA ZONE SOIT DÉPOURVUE D’ÉLÉMENTSINFLAMMABLES.

AVERTISSEMENT - RISQUE D'EXPLOSION – LA SUBSTITUTION DE TOUT COMPOSANT PEUT NUIRE A LACONFORMITÉ DE LA CLASSE I, DIVISION 2.

Do not operate the device in areas where blasting is in progress, where explosive atmospheres may be present,near medical equipment, near life support equipment, or any equipment which may be susceptible to any form ofradio interference. In such areas, the device MUST BE POWERED OFF. The device can transmit signals thatcould interfere with this equipment.

Do not operate the device in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the deviveMUST BE POWERED OFF. When operating, the device can transmit signals that could interfere with variousonboard systems.

Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door isopen. The device may be used at this time.

The driver or operator of any vehicle should not operate the device while in control of a vehicle. Doing so willdetract from the driver or operator's control and operation of that vehicle. In some states and provinces, operatingsuch communications devices while in control of a vehicle is an offense.

WARNING – EXPLOSION HAZARD – DO NOT REPLACE ANTENNAS UNLESS POWER HAS BEENSWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.

6 Installation OWL IPGRelease 01, 01/2020

Page 7: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

FCC Note

Supplier's Declaration of Conformity47 CFR § 2.1077 Compliance Information

OWL-IPG-AMERICAS

U.S. Contact InformationBelden – St. Louis1 N. Brentwood Blvd. 15th FloorSt. Louis, Missouri 63105, United StatesPhone: 314.854.8000

This device complieswith part 15 of the FCC rules. Operation is subject to the following two conditions:

l This devicemaynot cause harmful interference, and

l This devicemust accept any interference received, including interference that maycause undesired operation.

This equipment hasbeen tested and found to complywith the limits for a ClassA digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipmentgenerates, usesand can radiate radio frequencyenergyand, if not installed and used in accordance with the instructions, maycauseharmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular install-ation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning theequipment off and on, the user is encouraged to try to correct the interference byone or more of the followingmeasures:

l Reposition the receiver antenna or change the angle of the receiver antenna.

l Increase the separation between the device and the receiver.

l Connect the device to a different outlet on a different power supply cable from that to which the receiver is connected.

l Consult a specialist retailer or an electronic systemsengineer for help.

Changesor modificationsnot expressly approved by the holder of the certificate could void the user’s authority to operate this equip-ment.

This device is configured for operation in the USAduringmanufacturing. These configuration controls are not present in the softwarewith which the unit is shipped; therefore the end user cannot change the power settings, frequencyor the country/region.

Contains Transmitter ModuleFCC ID: N7NMC7355IC: 2417C-MC7355

PLEASESEEFCC ID LABELON BACKOF DEVICE.

Industry Canada Requirements:

THE INSTALLEROF THISRADIOEQUIPMENT MUST INSURETHAT THEANTENNA IS LOCATEDOR POINTED SUCHTHAT IT DOESNOT EMIT RF FIELD IN EXCESSOF HEALTH CANADALIMITSFOR THEGENERALPOPULATION;CONSULT SAFETYCODE6, OBTAINABLEFROMHEALTH CANADA.

7Installation OWL IPGRelease 01, 01/2020

Page 8: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

2 About This ManualThe “Installation” user manual contains a device description, safety instructions, a description ofthe display, and the other information that you need to install the device.

Documentationmentioned in the “User Manual Installation” that is not supplied with your deviceas a printout can be found as PDF files for download at: https://www.doc.hirschmann.com.

Maintenance and Service

l When designing this device, Hirschmann largely avoided using high-wear parts. The partssubject to wear and tear are dimensioned to last longer than the lifetime of the productwhen it is operated normally. Operate this device according to the specifications.

l Relays are subject to natural wear. This wear depends on the frequency of the switchingoperations. Check the resistance of the closed relay contacts and the switching functiondepending on the frequency of the switching operations.

l Hirschmann is continually working on improving and developing their software. Check reg-ularly whether there is an updated version of the software that provides you with additionalbenefits. You find information and software downloads on the Hirschmann product pagesat: http://www.hirschmann.com.

Note: You can find information on settling complaints at:http://www.beldensolutions.com/en/Service/Repairs/index.phtml.

8 Installation OWL IPGRelease 01, 01/2020

Page 9: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

3 Start Here3.1 About the OWL-IPG-AMERICAS Industrial Cellular GatewayTheOWL-IPG-AMERICAS Industrial Cellular Gateway provides secure wireless Ethernet andserial connectivity to remote devices over 4GLTE cellular serviceswith fallback to 3G. Thesedevices include PAC/PLCs, RTUs, DCS systems, instruments, electronic billboards and com-munication towers.

TheOWL-IPG-AMERICAS is ideal for programming andmaintenance of remote equipment,remote data collection, SCADA, andmachine-to-machine (M2M) applications. It operates onLTE/GSMandCDMA networkswith a single device.

TheOWL-IPG-AMERICAS supports:

l 4GLTE with GSMandCDMA cellular technologiesl Cellular networksworldwidel Secure VPN connections over internet and cellular links for remote site access to corporatenetworks (VPN Client Mode)

l Simultaneous Ethernet and serial data port (Modbus & DF1 encapsulation) com-munications providing SCADAmigration path to cellular for serial and Ethernet devices.

l Built-in web server for local/remote configuration, monitoring, and wireless network dia-gnostics.

9 Installation OWL IPGRelease 01, 01/2020

Page 10: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

3.1.1 Specifications

Cellular ModemSpecification DescriptionCellular Technology LTE, GSM, UMTS/HSPA+, GPRS, EDGE, CDMA

Frequency/Bands

OWL-IPG-AMERICAS-A:Frequency: 700 / 800 / 850 / 900 / 1700 / 1800 / 1900 / 2100 MHzHSPA and HSPA+ Bands: 1,2,4,5,8LTE Bands: 2,4,5,13,17,25Quad-band EDGE/GPRS/GSMCDMA/EVDO Bands: BC0, BC1, BC10

OWL-IPG-AMERICAS-E:Frequency: 800 / 850 / 900 / 1800 / 1900 / 2100 / 2600 MHzHSPA and HSPA+ Bands: 1,2,5,8LTE Bands: 1,3,7,8,20Quad-band EDGE/GPRS/GSM

Max Downlink Speeds Up to 100 Mbps maximum (network dependent)Max Uplink Speeds Up to 50 Mbps maximum (network dependent)Activation SIM SlotSecurity OpenVPN client, IPSec client, IP Address Filtering

PhysicalSpecification DescriptionEnclosure Extruded aluminum with DIN clipDimensions (H x W x D) 5.52 x 2.06 x 4.37 in, 14.01 x 5.24 x 11.09 cm

Shock IEC 60068-2-27; 20G@ 11ms (Operational)IEC 60068-2-27; 30G@ 11ms (Non-Operational)

Vibration IEC 60068-2-6; 10G, 10 to 150 HzEthernet Port (1) 10/100 Base-T, RJ45 connectorSerial Port (1) DB9 female (serial tunneling & encapsulation)Antenna Ports (2) Female SMA connector. Antennas sold separatelyWeight 14.5 oz (411 g)Enclosure Extruded aluminum with DIN clip

EnvironmentalSpecification DescriptionOperating Temperature IEC 60068 -40°F to +158°F (-40°C to +70°C)Humidity IEC 60068-30 5% to 95%, with no condensationExternal Power 10 to 30 VDCPeak Power Consumption < 6W

10Installation OWL IPGRelease 01, 01/2020

Page 11: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

3.2 Package ContentsThe following components are included with the OWL-IPG-AMERICAS and are required forinstallation and configuration.

Note: Before beginning the installation, please verify all of the following items are present.Qty. Part Name Part Number Part Description1 OWL-IPG-AMERICAS Cellular Gateway OWL-IPG-AMERICAS 3G/4G LTE

1 Industrial Cellular Gateway Connector Kit ICG-CON

Contains:(1) Power Connector(1) Wire Installation Tool(1) Two-pin jumper

If any of these components aremissing, please contact Hirschmann Support for replacementparts.

3.3 JumpersThe three sets of jumpers on the back of the unit are described from top to bottom:Jumper Position Description

(Not visible) Factory Use Only

Temporarily sets the LAN IP address to 192.168.0.250.

The Two-pin Jumper should be kept on until the unit boots and becomes accessible. Itremains at this address as long as the Two-pin Jumper is in place, regardless of theLAN IP address configured on the web server.

The OWL-IPG-AMERICAS reverts to the configured server address once the Two-pinJumper is removed.Resets the OWL-IPG-AMERICAS to factory defaults.

The Two-pin Jumper should be kept until all the LEDs start to slowly blink. At thispoint, the Two-pin Jumper should be removed and the unit should be power cycled.After doing so, the front panel LEDs blink continuously, but the unit will not operateany further. Remove the Two-pin Jumper and power cycle the device to restore nor-mal operations with factory defaults.

The custom username/password will also be reset to the defaults values.

11 Installation OWL IPGRelease 01, 01/2020

Page 12: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

3.4 Reset (Power Cycle) ButtonThe reset button is located at the bottom of the front panel of the OWL-IPG-AMERICAS.

12Installation OWL IPGRelease 01, 01/2020

Page 13: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4 Hardware InstallationTheOWL-IPG-AMERICAS should bemounted in a position that allows easy access for thecables so they are not bent, constricted, in close proximity to high amperage, or exposed toextreme temperatures. The LEDs on the front panel should be visible for ease of operational veri-fication. Ensure that there is adequate airflow around the device but kept free from direct expos-ure to the elements, such as sun, rain, dust, etc.

Caution: TheOWL-IPG-AMERICAS is in a hardened case, and designed for use in industrialand extreme environments. However, unless you are using cables expressly designed for suchenvironments, they can fail if exposed to the same conditions the OWL-IPG-AMERICAS can with-stand.

4.1 Power RequirementsTheOWL-IPG-AMERICAS accepts voltages between 10 and 30 VDC, with an average powerdraw of 3 watts or less.

A detachable Power Connector comeswith the radio, as shown below. The terminals are labeled+ (positive DC connection) and - (DC ground connection).

13 Installation OWL IPGRelease 01, 01/2020

Page 14: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

Note:Whenwiring the supplied Power Connector, be sure to observe the proper polaritymark-ings. Incorrect wiring can cause serious damage to the gateway, which will not be covered underthe warranty.

The Power Connector is shown on the left. Note the + and – polaritymarkings. TheWire Install-ation Tool, shown on the right, is helpful for installing wires into the spring-loaded contacts insidethe Power Connector.

14Installation OWL IPGRelease 01, 01/2020

Page 15: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

To use theWire Installation Tool, insert it into the Power Connector as shown:

Press down on theWire Installation Tool to use it as a lever to open the Power Connector’s con-tacts to insert a wire. A properly-wired Power Connector is shown:

4.2 Antenna InstallationAntennas selected should not exceed amaximumgain of 5 dBi under standard installation con-figuration. In more complex installations (such as those requiring long lengths of cable, and/or mul-tiple connections), it is imperative that the installer follow maximumdBi gain guidelines inaccordance with the radio communications regulations of the Federal CommunicationsCom-mission (FCC), Industry Canada, or your country's regulatory body (if used outside the US).

TheOWL-IPG-AMERICAS will work with most quad-bandGSM/CDMA cellular antennaswith afemale SMA connector. Connect the primary antenna or primary RF cable directly to the 'ANT A'antenna connector on the front of the OWL-IPG-AMERICAS.

A secondary antenna port labeled 'ANT B' is provided to attach an additional antenna. Use of asecondary antenna is not required, but will often increase cellular reliability and throughput per-formance.

This device is not intended for use within close proximity of the human body. Antenna installationshould have at least 20 cm separation from the operator.

Tip:When using a cable to an antenna placed away from themodem, minimize the length of yourcable. All gain from amore advantageous antenna placement can be lost with a long cable to themodem.

15 Installation OWL IPGRelease 01, 01/2020

Page 16: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4.3 Connecting the Radio to a Network Device

The application ports are located on the front of the radio.

l The Ethernet port uses a standard RJ45 connectorl The serial port uses a standard DB9 connector for serial connectivity

16Installation OWL IPGRelease 01, 01/2020

Page 17: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4.3.1 Ethernet Cable SpecificationsThe recommended Ethernet cable is category 5 or better. A category 5 cable has four twistedpairs of wire that are color-coded and cannot be swapped. Themodule only uses two of the fourpairs when running at 10MBit or 100MBit speeds.

The Ethernet port on themodule is Auto-Sensing. Use either a standard Ethernet straight-through cable or a crossover cable when connecting themodule to an Ethernet hub, a10/100/1000 Base-T Ethernet switch, or directly to a PC. Themodule will detect the cable typeand use the appropriate pins to send and receive Ethernet signals.

Ethernet cabling is like U.S. telephone cables but have eight conductors. Some hubs have oneinput that can accept either a straight-through or crossover cable, depending on switch position. Inthis case, ensure that the switch position and cable type agree.

Ethernet Cable Configuration

Note: The standard connector view shown is color-coded for a straight-through cable.

Crossover Cable Straight-through CableRJ45 Pin (Connector 1) RJ45 Pin (Connector 2) RJ45 Pin (Connector 1) RJ45 Pin (Connector 2)1 Rx + 3 Tx + 1 Rx + 1 Tx +2 Rx - 6 Tx - 2 Rx - 2 Tx -3 Tx + 1 Rx + 3 Tx + 3 Rx +6 Tx - 2 Rx - 6 Tx - 6 Rx -

17 Installation OWL IPGRelease 01, 01/2020

Page 18: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4.3.2 Serial Port Basics

RS-232

The use of hardware handshaking (control andmonitoring of signal lines) depends on the require-ments of the networked device. If no hardware handshaking will be used, the cable to connect tothe port is as shown below:

If hardware handshaking is required, the cable to connect to the port is as shown below:

18Installation OWL IPGRelease 01, 01/2020

Page 19: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4.4 LED Indicators

LED State Description

PWR Off Power is not connected to the power terminals or source is insufficientto properly power the device.

Solid Green Power is connected to the power terminalsERR Off Normal operation

Solid RedA critical error has occurred. Program executable has failed or hasbeen user-terminated and is no longer running. Press the Reset buttonor cycle power to clear the error.

MS* (ModuleStatus) Off OWL-IPG-AMERICAS is powered off

Solid Green Initialization complete / OKBlinking Green OWL-IPG-AMERICAS is in the process of configuringSolid Red Unrecoverable errorBlinking Red Reading configuration / minor error / No SIM

NS* (NetworkStatus) Off OWL-IPG-AMERICAS is powered off

Solid Green OWL-IPG-AMERICAS has a connection to cellular towerBlinking Green OWL-IPG-AMERICAS is attempting to connect to cellular towerSolid Red Duplicate IP (EtherNet/IP) / Non-recoverable network faultBlinking Red Established connection timeout (EtherNet/IP) / Minor network fault

* The MS and NS LED’s are only enabled if the Ethernet/IP parameter is enabled in the Configuration tab of thewebpage.

Serial Port LEDsLED State DescriptionSER Flashing Indicates that data is moving from the serial port to the WAN portTX Off No activity on the port

Flashing Amber Port is actively transmitting dataRX Off No activity on the port

Flashing Green Port is actively receiving data

Ethernet Port LEDsLED State Description100 Mbit Off No activity on the port

Flashing Amber The Ethernet port is actively transmitting or receiving data.

LNK/ACT Off No physical connection is detected. No Ethernet communication is pos-sible. Check wiring and cables.

Solid Green Physical network connection detected. This LED must be ON (solid) forEthernet communication to be possible.

19 Installation OWL IPGRelease 01, 01/2020

Page 20: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

WWAN LEDLED State DescriptionOff Off OWL-IPG-AMERICAS is powered off

Solid Green On OWL-IPG-AMERICAS is powered and connected, but is not trans-mitting or receiving.

Slow Blink Flashes at a slowrate: 0.2 Hz (5 sec) OWL-IPG-AMERICAS is powered and searching for a connection.

Faster BlinkFlashes at a fastrate: About 3 Hz(333 ms)

OWL-IPG-AMERICAS is transmitting or receiving data.

Note: TheWWAN LED indicates a physical connection state between theOWL-IPG-AMERICAS and the cell tower. It is not an indicator of a logical connection state. Theremay be asituation when youmay see a “Disconnect, will retry” indicator on theOWL-IPG-AMERICASwebpage, even when theWWAN LED light is on (solid green). This indicates that themodule wasable tomake a physical connection to the tower, but the logical connection was not made betweentheOWL-IPG-AMERICAS and the cellular provider.

20Installation OWL IPGRelease 01, 01/2020

Page 21: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5 Connecting to the OWL-IPG-AMERICASTheOWL-IP-AMERICAS configuration webpage is used to configure andmanage theOWL-IPG-AMERICAS. First-time setupmust be performed over a wired network, where provider-spe-cific cellular configuration details are configured. Once initially set up, you can access the web-server over the LAN and cellular networks (unless LAN access is disabled).

Key benefits of the web-based configurator include:

l Login and device parameter configurationl Network setting adjustmentsl Security settingmaintenancel Event reporting updatel Firmware installs

5.1 Configuration Webpage Setup1. Insert the SIM card (size 2FF, Mini-SIM) on the front of themodule.2. Ensure that themodule is connected to the network.3. Apply power to themodule (10 to 30 VDC).4. Open a web browser and enter the OWL-IPG-AMERICAS default address of

http://192.168.0.250:8080.5. If your PC is on a different subnet, temporarily set the IP address of your PC to

192.168.0.xxxwith a subnet of 255.255.255.0.

6. Once theOWL-IPG-AMERICAS homepage opens, enter the default credentials to log in:USER: adminPASSWORD: private

Be sure to customize your password once you log in. You can do this by navigating toAdministrator > Access Control > Web Login.

Note: After a factory reset, theUser andPassword fields will revert back to their defaults.

21 Installation OWL IPGRelease 01, 01/2020

Page 22: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

7. After successful login, the homepage displays data from theStatus tab.

22Installation OWL IPGRelease 01, 01/2020

Page 23: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.2 Assigning a LAN IP Address1. Select theConfiguration tab and then selectBASIC.

2. Enter a name for themodule in theModule Name field.3. Enter theAPN (Access Point Name). This information is provided by your cellular provider.

4. Internet Access via LAN is also possible. Enable this parameter and then clickAPPLY. Youwill be asked to enter a gateway and 2 DNS servers.Note:WAN interface is disabled when LAN is enabled.

5. Enter the IP Address andSubnet Mask of the OWL-IPG-AMERICAS.

6. Choose whether or not to useDHCP (Dynamic Host Configuration Protocol) for enddevices.

a) If YES, enable theDHCP SERVER option and select aDHCP Range of IP addressesapplicable tomultiple end devices.

23 Installation OWL IPGRelease 01, 01/2020

Page 24: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

•DHCP Range – This allows you to enter a range of IP addresses that can be addressed.For example, if you have a number of devices connected to a remote OWL-IPG-AMERICAS, you can enter the DHCP range to use on devices connected to the remoteOWL-IPG-AMERICAS.

• Lease Time – Enter the desired lease time using seconds, minutes, or hours.

b) For each End Device, set the TCP/IPv4 properties (Found atControl Panel /Networkand Internet / Network Connections) as follows:

c) If NO,Disable the DHCP option.

24Installation OWL IPGRelease 01, 01/2020

Page 25: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

d) On the laptop, set the TCP/IPv4 properties as follows. Non-PC devices, such PLC’s, donot require thePreferred DNS Server entry.

7. In the OWL-IPG-AMERICAS configuration webpage, clickAPPLY. The page auto-matically redirects to the new IP address if the IP address is changed.

8. Reset your PC back to its original IP address. This IP address should be on the same sub-net as the OWL-IPG-AMERICAS.

9. Close your browser and open a new session. Enter the new IP address of the OWL-IPG-AMERICAS to access the configuration web page. Add :8080 to specify the correct port(192.168.0.250:8080).

25 Installation OWL IPGRelease 01, 01/2020

Page 26: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.3 Connecting to Your Cellular ProviderTheOWL-IPG-AMERICAS supports 3GGSM/GPRS and 4GLTE (where applicable) networks.It uses your cellular provider as an ISP (Internet Service Provider) to connect to the Internet. Allcellular service connections require a Subscriber IdentityModule (SIM) to be installed in the OWL-IPG-AMERICAS. This includes connections to CDMA based services like Verizon (previously didnot require a SIM). Contact your service provider to obtain a SIM.

5.3.1 Connection Using GSM/GPRSThe Subscriber IdentityModule (SIM) in the OWL-IPG-AMERICAS is a smartcard that securelystores the key identifying a cellular subscriber. Generally, you will only need to install a SIM oncein the life of the cellular gateway - and it may already be pre-installed.

Note: Your cellular provider must provide the Public APN and IP address of the SIM card.

AT&T Users: For SMS texting functionality, youmust power up theOWL-IPG-AMERICAS withthe SIM installed within 72 hours after AT&T activates the SIM card.

The SIM card slot is located on the front of the cellular gateway.

1. Remove the SIMCard Slot cover by removing the two screws holding it into place.2. Insert the SIM card (size 2FF, Mini-SIM) into the OWL-IPG-AMERICAS and cycle power.

The SIM card is read by theOWL-IPG-AMERICAS upon boot up.3. Re-attach the SIMCard Slot cover.

26Installation OWL IPGRelease 01, 01/2020

Page 27: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

4. Enter the APN (Access Point Name) in theConfiguration > Basic,GatewaySettings.The APN is provided by your cellular provider.

5. After the OWL-IPG-AMERICAS reboots, it establishes a link to your cellular provider net-work, also called registering on the network, and then receives an IP address.

6. When theOWL-IPG-AMERICAS receives its IP address from the cellular provider, a con-nection to the Internet or the cellular network is also available for computers or otherdevices to connect directly to the OWL-IPG-AMERICAS.

7. TheGSMnetwork information is now displayed on theStatusweb page.

27 Installation OWL IPGRelease 01, 01/2020

Page 28: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.3.2 Connection Using CDMA1. When theOWL-IPG-AMERICAS is powered on, it automatically searches for cellular ser-

vice using CDMA-based cellular technology.2. TheOWL-IPG-AMERICAS establishes a PPP (Point-to-Point Protocol or "dial" up con-

nection) link to the cellular network, also called registering on the network, and receives anIP address.

3. When theOWL-IPG-AMERICAS has received its IP address from the cellular provider, aconnection to the Internet or the cellular network is also available for computers or otherdevices to connect directly to the OWL-IPG-AMERICAS.

4. The CDMA network information is now displayed on theStatusweb page.

5.3.3 SIM Card SecurityTo protect a SIM card from others using it for phone calls or cellular data, a SIMPIN can be used.When a SIMPIN is used, the SIM card will automatically lock upon anOWL-IPG-AMERICASreboot. The PIN protection enablement, PIN (Personal identification number), and PUK (PINunlock key) codes are saved on the SIM card. Replacing the SIM card requires a reconfigurationof the SIM settings.

Most mobile devices offer SIMPIN protection. At startup, if the PIN security function is active, theuser must enter a 4 to 8 digit PIN to enable the OWL-IPG-AMERICAS’s non-emergency func-tions. You can save the PIN code in the configuration in an encrypted format.

28Installation OWL IPGRelease 01, 01/2020

Page 29: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.3.4 SIM Card PIN VerificationThe SIMCard PIN Verification enables the OWL-IPG-AMERICAS’s non-emergency functions.By default, this feature is not enabled. The following steps show how to enable (and disable) thisfeature:

1. On theOWL-IPG-AMERICAS webpage, navigate to theCONFIGURATION > BASICwebpage.

2. Under SIMSettings, click on the PIN Verification setting and selectENABLE.

3. Enter a 4 to 8 digit PIN Code. You can display the digits by clicking theShow Charactersbox.

4. You can save the PIN code in the configuration in an encrypted format by clicking theSavePIN box.

29 Installation OWL IPGRelease 01, 01/2020

Page 30: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5. When ready, click theAPPLY button to apply the changes.6. When successful, the followingmessage displays:

7. To disable this feature, selectDisable from step 2 above and continue through the steps.

Note: If the wrong PIN Code is entered and submittedmore than three times, the SIM cardbecomes blocked. (Notice the number of Remaining tries in the top right corner of the SIMSettings area). The SIM card can be unblocked by entering a PUK code, provided by theservice provider (Example: AT&T). The next section discusses the unblocking process.When the SIM card is blocked, you will not be able to access theOWL-IPG-AMERICASconfiguration webpage via theWAN connection. You can connect via the LAN (Ethernet)port until the SIM card is unblocked.

30Installation OWL IPGRelease 01, 01/2020

Page 31: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.3.5 Unblocking a SIM CardIf the wrong PIN Code is enteredmore than three times, the SIM card becomes blocked. Duringthis time, OWL-IPG-AMERICASWAN (cellular) connectivity is disabled. The SIMPIN statusshows “SIM Blocked” on theSTATUS > SYSTEM STATUS webpage (WAN section). You canunblock it by entering the PUK code assigned to the SIM card by your service operator.

1. To unblock the SIM card, click theUNBLOCK link from theSTATUS > SYSTEMSTATUS webpage (WAN section).

31 Installation OWL IPGRelease 01, 01/2020

Page 32: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

2. The link takes you to theCONFIGURATION > BASIC webpage (SIMSettings section).

3. Contact your service provider to provide you with the PUK code. You will need the phonenumber that is assigned to the SIM card.

Note: It is recommended to keep the PUK written down in a safe place from the device.Entering an incorrect PUK code ten times in a row will permanently lock the SIM card,requiring a new one.

4. Once you obtain the PUK code, enter thePUK Code and aNew PIN Code.

5. ClickAPPLY.

32Installation OWL IPGRelease 01, 01/2020

Page 33: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

6. Upon success, the followingmessage is displayed:

7. TheSIMStatus is now Unlocked. PIN Verification can be enabled, as needed.

33 Installation OWL IPGRelease 01, 01/2020

Page 34: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

5.4 Connecting to the Internet Using the OWL-IPG-AMERICASInternet connectivity through theOWL-IPG-AMERICAS is achieved using the following steps:

1. Connect the laptop LAN port to the Ethernet port on theOWL-IPG-AMERICAS.2. On the laptop, set the TCP/IPv4 properties as follows:

Where:• IP address = The assigned IP address of your laptop.• Default gateway = The assigned IP address of the OWL-IPG-AMERICAS IP.• Preferred DNS Server = 8.8.8.8 (Google)• Alternate DNS Server = 8.8.4.4 (Google alternate)

3. ClickOK.4. Open your web browser on your laptop to connect to the internet.

34Installation OWL IPGRelease 01, 01/2020

Page 35: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport

6 Further SupportMaintenanceHirschmann is continually working on improving and developing their software. Check regularlywhether there is an updated version of the software that provides you with additional benefits.You find information and software downloads on the Hirschmann product pages on the Internet(http://www.hirschmann.com).

Technical QuestionsFor technical questions, please contact anyHirschmann dealer in your area or Hirschmann dir-ectly.

You find the addresses of our partners on the Internet at http://www.hirschmann.com.

A list of local telephone numbers and email addresses for technical support directly fromHirschmann is available at https://hirschmann-support.belden.com.

This site also includes a free of charge knowledge base and a software download section.

Technical DataYouwill find the technical data in the document “User Manual Installation”.

Documentationmentioned in the “User Manual Installation” that is not supplied with your deviceas a printout can be found as PDF files for downloading on the Internet at: https://www.-doc.hirschmann.com

Hirschmann Competence CenterTheHirschmannCompetence Center is ahead of its competitors on three counts with its com-plete range of innovative services:

l Consulting incorporates comprehensive technical advice - From system evaluation,through network planning, to project planning.

l Training offers you an introduction to the basics, product briefing and user training with cer-tification. You can find the training courses on technology and products currently availableat http://www.hicomcenter.com.

l Support ranges from the first installation through the standby service tomaintenance con-cepts.

With the HirschmannCompetence Center, you decided against making any compromises.Our client-customized package leaves you free to choose the service components you want touse.

Internet: http://www.hicomcenter.com

35 Installation OWL IPGRelease 01, 01/2020

Page 36: Installation: OWL IPG AMERICAS, Rel. 01, 01/2020 · 2020-01-29 · UserManual Installation IndustrialCellularRouter OWL-IPG-AMERICAS InstallationOWLIPG Release01,01/2020 TechnicalSupport