www.certainteed.com 152 Standard Reveal Edge Panels INSTALLATION INSTRUCTIONS Installation Guide The diagrams contained in the following pages provide detailed pictures of recommended installation procedures for the systems that are part of the CertainTeed Ceilings product offering. Should any portion of this information provoke a question or require additional information, please contact CertainTeed Ceilings - Technical Services. Tel: 1.800.233.8990 Email: [email protected] Connect Angle trim Main runner (15/16" or 9/16") installed at 48" centers Hanger, installed at 48" centers Connect Shadow-line trim 24" Cross tee (15/16" or 9/16") 48" Cross tee (15/16" or 9/16") Reveal Edge Panel Main runner (15/16" or 9/16") installed at 48" centers 48" Cross tee (15/16" or 9/16") 24" Cross tee (15/16" or 9/16") SIZE IN INCHES QUANTITY SPECIFICATION (EXCLUDES OVERAGE) 24" x 48" 0.26 LF/SF 0.5 LF/SF 24" x 24" 0.26 LF/SF 0.5 LF/SF 0.26 LF/SF Optional wall junctions for reveal edge panel Rabbeted edge with angle trim Straight cut with Shadow-line trim
Transcript
Page 1: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com152

Standard RevealEdge PanelsI N S T A L L A T I O N I N S T R U C T I O N S

InstallationGuideThe diagrams contained in

the following pages provide

detailed pictures of recommended

installation procedures for the

systems that are part of the

CertainTeed Ceilings product

offering. Should any portion

of this information provoke a

question or require additional

information, please contact

CertainTeed Ceilings -

Technical Services.

Tel: 1.800.233.8990

Email: [email protected]

Connect Angle trim

Main runner (15/16" or 9/16")installed at 48" centers Hanger, installed

at 48" centers

Connect Shadow-line trim

24" Cross tee(15/16" or 9/16")

48" Cross tee(15/16" or 9/16")

Reveal Edge Panel

Main runner (15/16" or 9/16") installed at 48" centers

48" Cross tee (15/16" or 9/16")

24" Cross tee (15/16" or 9/16")

SIZE IN INCHESQUANTITY SPECIFICATION (EXCLUDES OVERAGE)24" x 48"

0.26 LF/SF

0.5 LF/SF

24" x 24"

0.26 LF/SF

0.5 LF/SF

0.26 LF/SF

Optional wall junctions for reveal edge panel

Rabbeted edgewith angle trim

Straight cut withShadow-line trim

Page 2: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 153

Module measures of corner

Hanger, installed at 48” centers

Connect 15/16”Cross tee

Connect 15/16”Main runner

Connect 15/16”Main runner

Connect Hook(3 pieces/cornerin corner kit)

Connect 15/16” Main runner withConnect F-trim 0464

Connect 15/16”Cross teeConnect 15/16”

Main runner withConnect F-trim 0464

Connect 15/16”Cross tee

Connect L-coupling (2 pieces/corner in corner kit)

Connect 15/16”Main runner

Connect 15/16”Main runner

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16" Main runner with Connect F-trim 0464

Focus L-line Horizontal Installation External Corner

Focus L-line HorizontalInstallation Internal Corner

Detail of lower part with F-trim Lower part with F-trim

Hanger, installedat 48” centers

Connect 15/16" Cross tee

Hanger, installedat 48" centers

Connect 15/16"Main runner

H=5-5/16"

c=24" centers

Connect 15/16" Main runner withConnect F-trim 0464

Connect 15/16" Cross tee

Edge B without profile

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon®

Focus™ 3-D L-LineHorizontal Installation

Page 3: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com154

Ecophon®

Focus™ 3-D L-LineVertical InstallationI N S T A L L A T I O N I N S T R U C T I O N S

Module measures of corner Detail of lower part with F-trim Lower part with F-trim Focus L-line panel

Connect 15/16" Cross tee

Hanger, installed at 48" centers

Connect 15/16" Cross tee

Connect L-coupling (2 pieces/corner in corner kit)

Connect 15/16" Main runner

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16" Main runner with Connect F-trim 0464

Connect 15/16" Cross tee

Connect 15/16" Main runner with

Connect F-trim 0464

Connect 15/16"Cross tee

Connect 15/16" Main runner

Hanger, installed at 48" centers

Connect L-coupling (2 pieces/corner in corner kit)

Connect 15/16" Cross tee

Connect 15/16" Main runner

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16" Main runner with

Connect F-trim 0464

Focus™ L-line Vertical Installation External Corner

Focus™ L-line Vertical Installation Internal Corner

Connect 15/16" Main runner

Edge B withoutprofile

Hanger, installedat 48" centers

Connect 15/16"Cross tee

H=23-1/2" centers

c=6-1/2"Connect 15/16" Main runnerwith Connect F-trim 0464

Connect 15/16"Main runner

I N S T A L L A T I O N I N S T R U C T I O N S

Page 4: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 155

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon®

Focus™ 3-DS-Line E 210

Module measures of corner

Hanger, installed at 48" centers

Connect 15/16" Cross tee

Connect L-coupling (2 pieces/corner in corner kit)

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16"Main runner

Connect 15/16"Main runner

Connect 15/16"Cross tee

Connect 15/16"Main runner

Connect 15/16"Cross tee

Connect 15/16" Crosstee S-line E 210

Connect 15/16"Main runner

Connect L-coupling(2 pieces/corner incorner kit)

Hanger, installed at 48" centers

Connect 15/16" Main runner

Connect Hook (3 pieces/cornerin corner kit)

Connect 15/16"Main runner

Focus™ S-line E 210Installation External Corner

Focus™ S-line E 210 Installation Internal Corner

48"

24"

Fitting of profiles with coupling

Connect 15/16" Cross tee

Connect 15/16" Main runner

Connect 15/16" Cross tee S-line E210, installed at 48" centers

Hanger, installed at48" centers

H=8-3/8"

c=24" centers

Connect 15/16"Main runner

Connect 15/16"Cross tee

Connect 15/16" Cross tee for

Focus™ S-lineE210

Page 5: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com156

Module measures of corner

Connect 15/16" Main runner

Connect 15/16"Cross tee

Connect L-coupling (2 pieces/corner in corner kit)

Connect 15/16"Main runner

Connect 15/16"Main runner

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16" Main runner withConnect F-trim 0464

Connect 15/16"Cross tee E 300 or

450 Concave

Connect 15/16" Main runner with

Connect F-trim 0464

Connect 15/16"Cross tee

Connect L-coupling (2 pieces/corner in corner kit)

Hanger, installedat 48" centers

Connect 15/16"Main runner

Connect 15/16"Main runnerwith ConnectF-trim 0464

Connect Hook (3 pieces/corner in corner kit)

Connect 15/16" Mainrunner with Connect

F-trim 0464

Focus™ Quadro E 300 and 450 ConcaveInstallation External Corner

Focus™ Quadro E 300 and 450 ConcaveInstallation Internal Corner

Detail of lower part with F-trim Internal corner, upper connectionbetween profiles

Connect 15/16"Main runner

Connect 15/16"Main runner

Connect 15/16" Cross tee

Connect 15/16" Cross teeE 300 or 450 Concave Connect 15/16"

Main runner

H=12" or 16-1/2" centers

c=12" or 16-1/2" centers

Connect 15/16" Main runnerwith Connect F-trim 0464

Connect 15/16" Cross tee

Connect 15/16"Cross tee

Hanger, installed at 48" centers

Ecophon®

Focus™ 3-D Quadro E300 and 450 ConcaveI N S T A L L A T I O N I N S T R U C T I O N S

Page 6: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 157

Connect Angle trim

Hanger, installed at 48" centers

Connect Wireclip 0024

Connect Access hatch

Connect T-spline

Connect Splice connector Z

Connect Shadow-line trimConnect Spline

Connect Z-profile 0227,installed at 2' or 4' centers

Connect 15/16" Main runner 8379,L=12', installed at 4' centers

Connection between profiles withwire clip

Splines are used to level tiles Live load/Load bearing capacity Vertical measurements

Connect 15/16" Main runner 8379, L=12', installed at 4' centers

Connect Wire clip 0024

Connect Z-profile 0227, installed at 2' or 4' centers

Connect Splice connector Z

Connect Spline

Connect T-spline

Hanger, installed at 48" centers

Connect Angle trim

Connect Shadow-line trim

24" x 24"

0.27 lft/ft2

0.125/ft2

0.5 lft/ft2

0.04/ft2

0.25/ft2

0.25/ft2

0.065/ft2

as required

as required

SIZE IN INCHESQUANTITY SPECIFICATION (EXCLUDES OVERAGE)

Max live load. Min. load bearing capacityfor suspension components.

Size (inches)Max liveload (lbs.)

Min load bearingcapacity (lbs.)

24" x 24"48" x 48"

11 11

35 35

Min. overall depth of system: 5-5/16"

Min. demounting depth: Individualceiling tiles are non-demountable

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Focus™ CSuspended Application

Page 7: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com158

Focus™ CRefer to adhesive manufacturer’s printedrecommendation for acoustic ceiling tileadhesive installation pattern.

Focus™ C: ConnectSplines 0209, L=6"

Installation in plasterboardor wood furring

Ecophon® Focus™ CAdhesive ApplicationI N S T A L L A T I O N I N S T R U C T I O N S

Connect Shadow-line trim Connect End Fixing plate

Connect 15/16" Corridor profile,installed at 24" centers

Connect Angle trim

Ecophon® Focus™ DIn CorridorsI N S T A L L A T I O N I N S T R U C T I O N S

Page 8: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 159

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Focus™ D2x2, 2x4,

2x5, 2x6, 2x8

Hanger installed on 48" centers(max. distance from wall 24")

Connect Space bar 0520, installed at 48" centers (max. distance from wall 24")

Connect HD Main RunnerInstalled 48" O.C.

Connect Wall bracketT-profile 0524

Ecophon® Focus™ D

Connect HD Main Runner (installed 24" O.C.) - in Lineal Feet

Connect T-profile Wall Bracket

Connect Space Bars (installed 48" O.C. - max. distance from wall = 24") - in Lineal Feet

Connect Space Bar Wall Bracket

Connect Split Pin - (installed through punched slot at every intersection of Space Bar & Main Runner)

Wall Molding - (angle, step or channel)

QUANTITY SPECIFICATION (EXCLUDES OVERAGES)

Connect Wall bracketSpace bar 0525

Connect Split pin 0523,installed one per jointMain runner/Space bar

0.5 x S.F. of Focus D

2 for every row of Main Runners

0.3 x S.F. of Focus D

2 for every row of Space Bars

5 Split Pins per Space Bar

as required

Page 9: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com160

Ecophon® Focus™ D4" x 4"I N S T A L L A T I O N I N S T R U C T I O N S

Connect Wall bracketT-profile 0524

Connect Edge stiffener 0380

Connect Split pin 0523,installed one per joint

Main runner/Space bar

Ecophon® Focus™ D

Connect HD Main Runner (installed 48" O.C.) - in Lineal Feet

Connect T-profile Wall Bracket

Connect Space Bars (installed 48" O.C. - max. distance from wall = 24") - in Lineal Feet

Connect Space Bar Wall Bracket

Connect Edge Stiffener

Connect Split Pin - (installed through punched slot at every intersection of Space Bar & Main Runner)

Wall Molding - (angle, step or channel)

0.25 x S.F. of Focus D

2 for every row of Main Runners

0.3 x S.F. of Focus D

2 for every row of Space Bars

2 pieces per panel

3 Split Pins per Space Bar

as required

QUANTITY SPECIFICATION (EXCLUDES OVERAGES)

Connect HD Main RunnerInstalled 48" O.C.

Connect Space bar 0520, installed on 48" centers (max. distance from wall 24")

Connect Wall bracketSpace bar 0525

Hanger installed on 48" centers(max. distance from wall 24")

Connect Angle trim 15/22

Page 10: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 161

Hanger, installed at 60" centers

Cut edge with Edge clip

Connect Angle trim(fixed at 12" centers)

Connect 15/16" Main runnerHD installed at 24" centers

Cut edge without Edge clip

Connect 15/16" Cross tee, L=24"Connect Support clipDG20 0547

Cutting tool DG 0991 Cut edge without Edge clip/withEdge clip

Hanger, installed at 48" centers

Connect Support ClipDG20

Connect 15/16"Main runner

Connect Angle trim(fixed at 12" centers)

Connect Crosstee, L=48"

Connect 15/16" Mainrunner HD installed at

48" centers

Cut edge without Edge clip Cut edge with Edge clip

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon®

Focus™ DG XL

Page 11: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com162

Connect Angle trim, fixedat 12" centers

Connect Anchor screw 4000 (for usein concrete) installed at 24" centersConnect Spline 0209,

L=5-5/16"

Connect Spline 0209

Connect Wall springspacer 0087

Connect Installation screw (foruse with plasterboard and wood)installed at 8" centers

Installation in concrete

Connect Direct fixing plate F 0149(for use in concrete) installed at24" centers

Ecophon®

Focus™ WingI N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Focus™ FI N S T A L L A T I O N I N S T R U C T I O N S

Focus™ Wing DConnect Space Bar

Focus™ Wing DFocus™ Wing D

Focus™ Wing D

Focus™ Wing D/Ecke linksFocus™ Wing D

/Ecke rechts

Connect HDmain runner

Page 12: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 163

Connect Hygiene™ Inspection(not fire resistant)

Hanger, installed at 48" centers

Connect Hygiene™ clip 20, 0172(for 3/4" thickness)

Connect 15/16" Cross tee, L=48"

Connect Channel trim(for 3/4" thickness)

Connect 15/16" Main runnerat 48" centers

Ecophon Hygiene™ Performance A, Protec A, Advance A

Connect 15/16" Cross tee, L=48"

Connect 15/16" Cross tee, L=24"

Connect Hygiene™ Inspection (not fire resistant)

Connect Hygiene™ clip 20, 0172 (for 3/4" thickness)

Connect Channel trim C3 3532 (for 3/4" thickness)

Hygiene Advance perimeter panel

Connect Hygiene Sealant 0041

SIZE IN INCHESQUANTITY SPECIFICATION (EXCLUDES OVERAGE)24" x 48"

0,27 lft/ft2

0,5 lft/ft2

-

as required

0,65/ft2

as required

as required

as required

24" x 24"

0,27 lft/ft2

0,5 lft/ft2

0,27 lft/ft2

as required

1/ft2

as required

as required

as required

Arrangement of clips

Connect 15/16" Cross tee, L=24"

Clips for keeping tiles in position Live load/Load bearing capacity Vertical measurements

Min. overall depth of system: 6"

Min. demounting depth: 6"

Max live load. Min. load bearing capacityfor suspension components.

Size (inches)Max liveload (lbs.)

Min load bearingcapacity (lbs.)

24" x 24"24" x 48"24" x 60"24" x 72"24" x 96"

11 11 11 11 11

35 35 35 35 35

Live load/Load bearing capacity

Max live load. Min. load bearing capacityfor suspension components.

Size (inches)Max liveload (lbs.)

Min load bearingcapacity (lbs.)

24" x 24"24" x 48"

99

35 35

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Hygiene™

Performance A, Protec A, Advance A

Page 13: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com164

Connect 15/16" Main runner C39101,installed at 48" centers Connect Baffle clip 0201

Connect 15/16" Cross tee C39105, L=48",installed at 54" centers

Installation in checkered pattern

48"

54"

Detail of suspension

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Hygiene™

Protec/Advance Bafflein Checkered Pattern

Page 14: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 165

Connect 15/16" Main runner,installed at 24" centers Connect Baffle clip 0201

Connect 15/16" Cross tee, L=24",installed at 72" centers

Installation in rows

24" 24"

Detail of suspension

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Hygiene™

Protec/AdvanceBaffle In Rows

Page 15: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com166

Connect Wall fixing plate 1111 lower

Connect Wall fixing plate 1110 upper

Detail of upper fixing Detail of lower fixing

Connect Wall fixing plate 1111 lower

Connect Wall fixing plate 1110 upper

1800 x 1200

1 pc/Baffle

1 pc/Baffle

SIZE IN MMQUANTITY SPECIFICATION (EXCLUDES OVERAGE)

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Hygiene™

Protec Wall Baffle

Page 16: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

Technical Support 1-800-233-8990 167

Connect 15/16" Main runner,installed at 48" centers

Connect Angle trim

Connect 15/16"Cross tee, L=48"

Connect Shadow-line trim Connect 15/16"Cross tee, L=24"

12 Master Extra Bass 48" x 24" x 4"

Connect 15/16" Main runner,installed at 48" centers

Connect Angle trim

Connect Shadow-line trim

Connect 15/16" Cross tee, L=24" Connect 15/16"Cross tee, L=48"

Optional wall junctions for Master™ E

Rabbeted withAngle trim

Rabbeted withShadow-line trim

Straight cut withShadow-line trim

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon®

Master™ A, E

Page 17: Installation Standard Reveal Guide Edge Panels...160 Ecophon ® Focus D 4" x 4" INSTALLATION INSTRUCTIONS Connect Wall bracket T-profile 0524 Connect Edge stiffener 0380 Connect Split

www.certainteed.com168

Rigid hanger made of Connect Angletrim, max. L=48” at 48” centers

Connect Impact bracing

Connect Channel trim 0261

Connect 15/16”Cross tee, L=24”

Ecophon Super G™ A

Connect 15/16" Main runner, installed at 24" centers

Connect 15/16" Cross tee, L=24"

Rigid hanger made of Connect Angle trim, max. L=48" at 48" centers

Connect Impact bracing

SIZE IN INCHESQUANTITY SPECIFICATION (EXCLUDES OVERAGE)24" x 48"

0,5 lft/ft2

0,25 lft/ft2

0,13/ft2

(3/panel)

24" x 24"

0,5 lft/ft2

0,5 lft/ft2

0,13/ft2

(2/panel)

Connect 15/16” Main runner,installed at 24” centers

Detail of suspension Connection between profiles withsplit pin

Live load/Load bearing capacity Vertical measurements

Min. overall depth of system: 8"

Min. demounting depth: 8" (for tile withoutImpact bracing)

Max live load. Min. load bearing capacityfor suspension components.

Size (inches)Max liveload (lbs.)

Min load bearingcapacity (lbs.)

24" x 24"24" x 48"24" x 60"24" x 72"24" x 96"

11 11 11 11 11

35 35 35 35 35

Live load/Load bearing capacity

Max live load. Min. load bearing capacityfor suspension components.

Size (inches)Max liveload (lbs.)

Min load bearingcapacity (lbs.)

24" x 24"24" x 48"

99

35 35

I N S T A L L A T I O N I N S T R U C T I O N S

Ecophon® Super G™

With Impact Bracing


Recommended