18
Institut für Agrartechnologie und Biosystemte Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter, Dr. Heinz Sourell, Hans-Heinrich Thörmann, Federal Research Institute for Rural Areas, Forestry and Fisheries, Germany Institute of Agricultural Technology and Biosystems Engineering 27 June 2012, Adelaide German National Committee of ICID (GECID)
Transcript
Page 1: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

Institut für Agrartechnologie und Biosystemtechnik

Possibilities of using the drip irrigation laterals on centre pivot irrigation

machines

Jano Anter, Dr. Heinz Sourell, Hans-Heinrich Thörmann,

Federal Research Institute for Rural Areas, Forestry and Fisheries, GermanyInstitute of Agricultural Technology and Biosystems Engineering

27 June 2012, Adelaide

German National Committee of ICID (GECID)

Page 2: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

2Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Page 3: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

3Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Contents

• Irrigation in Germany

• Advantages & disadvantages of drip irrigation and center pivot

• Steps to mobile drip irrigation

• Technical aspects

• Costs analysis

• Summary

Page 4: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

4Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Irrigation in Germany

• 3% of the agricultural land are irrigated in Germany

• Humid climate, dry periods, sandy soils

• Cultures worth of irrigation: i.e. Potatos, Sugar beets

• Use of modern irrigation techniques

• The techniques are developed in terms of claims by farmers:- Water distrubtion - Intensity of labour - Water-efficient - Energy consumption

Page 5: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

5Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Water distribution-systems

Page 6: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

6Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Advantages & disadvantages of drip irrigation

+High water use efficiencyLow water lossesLow energy requirementsPossibility of chemigation

-High total costsHigh labour requirements for the assembly and disassembly

Page 7: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

7Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Advantages & disadvantages of center pivot with sprinkler

+Full-Automatic machine managementLow labour requirementsModerate capital requirementSimple to use

-Water lossesWind drift High energy requirements

Page 8: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

8Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Operating costs

Center Pivot

Drip Irrigation

Page 9: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

9Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Steps to mobile drip irrigation

Drip irrigation Center pivot

Mobile Drip Irrigation

Page 10: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

10Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Installation of mobile drip irrigation by centre pivot

Page 11: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

11Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Field experiments

The Center pivot consisting 9 towers

The total lenght of this pivot machine was approximately 428 m

The total irrigated area of about 57 ha

Drip tubes distance: 0.75 m

In the field investigations, two operating pressures were used at the inlet of the drip tubes (50 kPa and 100 kPa)

Page 12: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

12Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Emitters

Mobile drip irrigation needs emitters that have:

• High discharge (8 l/h & 10 l/h)• Low distance between them (0.15 m)

To reduce the lenght of drip tubes and the numbers of emitters

• High emission uniformity (over 95 %)• Low coefficient of variation (lower than 5 %)

To enhance irrigation water distrubtion on the soil surface

Page 13: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

13Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Length of drip tubes at two pressures

- The lenght of the drip tubes is dependent upon the emitter discharge and the distance from the pivot point

- The lenght of the drip tubes increases as the distance from the pivot point grows

- For the stability of the centre pivot irrigator, additional friction force is

important

- The friction force at 50 kPa were higher than the friction force at 100 kPa (2470 N & 1743 N at the ninth tower)

- This force is suitable for the electric motors which are mounted on each tower.

Page 14: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

14Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Length of drip tubes at two pressures

0

3

6

9

12

15

18

21

0 50 100 150 200 250 300 350 400 450

Lateral length of center pivot, m

Leng

th o

f dr

ip t

ubes

, m

50 kPa

100 kPa

Page 15: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

15Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Costs analysis (Capital requirement)

Item Unit Center Pivot sprinkler

Stationary drip irrigation

Mobile drip irrigation

Irrigated area ha 57.55 57.55 57.55Water required m3/ha 200 64 160No. of irrigations per season 5 12.5 5Total water required m3/ha per season 1000 800 800Energy requirement kWh/(ha*a) 360 128 208Total working time h/ha/season 0.5 9.975 0.75

Capital requirement (Initial cost)

€ 60,572 132,20056,225 * 15,487**

71,722 (Total)* = Pivot machine without sprinklers** = Only drip tubes, emitters and regulators

Page 16: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

16Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Costs analysis (Operating costs)

276209

906

590

158 127

0100200300400500600700800900

1000

SDI MDI CPSIrrigation system

Tot

al y

early

cos

ts,

Eur

o/ha

One season

Two seasons

Page 17: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

17Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Summary

• High water efficiency / Water saving up to 20%

• Energy conservation up to 40%

• The total costs of MDI were close to the total costs of a CP

• For the same area we need only 1,6 % respectively of the tubes that would needed for a SDI

• Filtering of the water can become important

• Further experiments with other plants is necessary

Page 18: Institut für Agrartechnologie und Biosystemtechnik Possibilities of using the drip irrigation laterals on centre pivot irrigation machines Jano Anter,

18Jano Anter, Hans-Heinrich Thörmann, Dr. Heinz Sourell

Many thanks for your attention!