Instrumentation Plant Bulks ............................................................. 21-3 Sensor/Loop Descriptions Pressure ......................................................................................... 21-7 Differential Pressure ...................................................................... 21-8 Temperature .................................................................................. 21-9 Flow ............................................................................................... 21-10 Level .............................................................................................. 21-11 Analyzers ....................................................................................... 21-12 Speed ............................................................................................. 21-13 Motion: Axial, Radial, Vibration .................................................. 21-14 Position .......................................................................................... 21-15 Weight ........................................................................................... 21-16 Conductivity .................................................................................. 21-16 Hand (Manual) Activation ............................................................. 21-17 Field Mounted Solenoid ................................................................ 21-17 Panel Action Descriptions .................................................................. 21-18 Panel Option Descriptions ................................................................. 21-19 Fisher Control Valve Information .................................................... 21-19 Control Valve Options ....................................................................... 21-20 Transmitter Type ................................................................................ 21-20 Overview of Instrumentation Report Details ................................... 21-21 Report Details for Analog/Electrical Instrumentation .................... 21-22 Report Details for Analog/Electrical Pneumatic Instrumentation .................................................................................. 21-23 Report Details for Digital/Electrical Instrumentation .................... 21-24 Report Details for Digital/Electrical Pneumatic Instrumentation .................................................................................. 21-25 Instrumentation 21 Chapter G2 © ICARUS Corporation, 1998.
Transcript
Page 1: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

Instrumentation Plant Bulks ............................................................. 21-3

Sensor/Loop DescriptionsPressure ......................................................................................... 21-7Differential Pressure ...................................................................... 21-8Temperature .................................................................................. 21-9Flow ...............................................................................................21-10Level .............................................................................................. 21-11Analyzers ....................................................................................... 21-12Speed ............................................................................................. 21-13Motion: Axial, Radial, Vibration.................................................. 21-14Position .......................................................................................... 21-15Weight ........................................................................................... 21-16Conductivity .................................................................................. 21-16Hand (Manual) Activation ............................................................. 21-17Field Mounted Solenoid ................................................................ 21-17

Panel Action Descriptions.................................................................. 21-18

Panel Option Descriptions................................................................. 21-19

Fisher Control Valve Information .................................................... 21-19

Control Valve Options ....................................................................... 21-20

Transmitter Type ................................................................................ 21-20

Overview of Instrumentation Report Details................................... 21-21

Report Details for Analog/Electrical Instrumentation .................... 21-22

Report Details for Analog/Electrical PneumaticInstrumentation .................................................................................. 21-23

Report Details for Digital/Electrical Instrumentation .................... 21-24

Report Details for Digital/Electrical PneumaticInstrumentation .................................................................................. 21-25

Instrumentation 21Chapter

G2 © ICARUS Corporation, 1998.

Page 2: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-2

© ICARUS Corporation, 1998. G2

ICARUS Reference

Page 3: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-3

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Instrumentation Plant Bulks

Instrumentation plant bulks include cable, tube bundles, tray and panels.

Description Type

1 Instrument panel, electronic/pneumatic INST-PANEL

Type:ELC - Electronic panelPNU - Pneumatic panelE/P - Combined electronic/pneumatic

2 Instrument cable tray INST-TRAY

Width: Range: 6 - 36 INCHES [150 - 910 MM];Default: *18* INCHES [*450* MM]

3 Electronic signal wire: wire, armored wire, wire in conduit INST-WIRE

Material Selection: Default: *IM*IM - Insul., standard wireARMOR - IM with interlock armorRIGID - IM in rigid conduit

No. Cond. Sets/Cable : Optional twisted pair or triad in each wire set.Range: 1 - 50.

Conductor Set Type: Default: *PAIR*PAIR - PairTRIAD - Triad

4 Instrument pneumatic multi-tube bundle runs PNU-TUBING

No. Tubes Per Bundle: Range: 7 - 19

5 Thermocouple wire: wire, armored wire, wire in conduit THCPL-WIRE

Material Selection: Default: *TM*TM - Insul., solid wineARMOR - TM with interlock armorRIGID - TM in rigid conduit

No. Cond. Pair/Cable: Optional number of twisted pairs per cable.Range: 1 - 36.

Conductor Type: Default: *JX*JX - Iron constantionKX - Chromel alumelTX - Copper Constanation

Page 4: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-4

© ICARUS Corporation, 1998. G2

ICARUS Reference

Instrumentation Plant Bulks - continued

Description Type

6 Instrument junction boxes: electronic, pneumatic, thermocouple JUNC-BOX

Junction Box Type:EL12 - Electronic - 12 conductorEL6 - Electornic - 6 conductorEL4 - Electronic - 4 conductorPN19 - Pneumatic - 19 tubesPN12 - Pneumatic - 12 tubesPN7 - Pneumatic - 7 tubesTC16 - Thermocouple - 16 conductorTC12 - Thermocouple - 12 conductorTC4 - Thermocouple - 4 conductor

Enclosure Type: Default: *GP*GP - General purposeEXPR - Explosion proof

7 Multifunction controllers: analog/digital I, IC, S, A circuits MULTI-CONTMultifunction controllers for indicating and control loops, and switch and alarmcircuits.

The Instrumentation Plant Bulk items referred to as Multifunction controllers, Highenergy level process interface units, and Low energy level process interface units arebased on elements of a Honeywell TDC 2000/3000 process control system.

A Multifunction controller consists of a metal cabinet (6 FEET tall [1.83 M] and19 INCHES [0.48 M] wide, containing 1 or more electronic controllers with a powersupply, analog and digital I/O signal processing cards mounted in electronic racks asdepicted in the following drawing.

continued

Page 5: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-5

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Instrumentation Plant Bulks - continued

Description Type

MULTI-CONT continued

The multifunction controller is programmed from the engineer’s station in the OperatorCenter over a redundant, coaxial cable (Data-highway cable). The controller polls theanalog and digital input cards which report to it to collect the signals transmitted by thefield sensors connected to those cards. The controller either passes the signal up to theOperator Center for permanent storage in a History Module (computer storage) and/orcompares the measured signal with the programmed set point and generates a correctivecommand. This corrective command is sent to output cards which, in turn, generateeither an analog (4-20mA for positioning control valves) or digital (for solenoids,on/off valves) control signal which is sent to the appropriate final control element in thefield.

The signals from and to the field interface to the Multifunction controller through ajunction box on the back plane of the unit. Signals are distributed within the unit over adata bus.

Electric power is required to support all the electronics and a cooling fan on top of theunit. Battery backup may be specified if it is important that the controller not lose itsability to control the processing in the event of a power outage. Redundantmultifunction controllers may be specified to insure continued control even in the eventof a failure in the primary controller.

High and low energy level PIUs look similar but have no controllers. The High levelPIUs are for analog inputs only (4-20mA) and provide simple control; the Low levelPIUs collect signals from thermocouple and RTD loops.

The are 3 type of temperature transmitters available:

• RTD (resistance temperature detector)• TC (thermocouple)• Filled system (liquid-filled).

The TDC2000/3000 controller handles 16 analog output per controller. The I/O cardshandle the following number of signals:

Signal Type No. Input No. Output SignalsSignals per Card Signals per Card

Analog 8 4Digital 16 8

No. of Controllers: One cabinet and power supply provided per two controllers.Redundancy: Redundancy provides 1 backup controller for up to eight primary

controllers. Default: *NONE*RED - Redundancy requiredNONE - No reduncancy

Analog Input Cards: Number of I/O cards for analog input (indcating).Analog Output Cards: Number of I/O cards for analog output (control).Digital Input Cards: Number of I/O cards for digital input (alarm).Digital Output Cards: Number of I/O cards for digital output (switch).No. Battery Backupus: Number of backup battery power supplies for multifunction

controllers. Default: *0*

Page 6: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-6

© ICARUS Corporation, 1998. G2

ICARUS Reference

Instrumentation Plant Bulks - continued

Description Type

8 High energy level process interface units: Indicator, switch, alarm circuits HL-PIU

Digital Input Cards: Enter number of input cards required.Digital Output Cards: Enter number of output cards required.

9 Low energy level process interface units: Thermocouple and RTD circuits LL-PIU

10 Data-highway cable, redundant (fiber optic) DATA-HIWAYCoaxial or fiber optic cables connecting digital controllers to operator centers.

Material Selection: Default: *COAX*COAX - Coax cableFIBER - Fiber optic cable

No. of Terminations: Min: 1; Default: *2*Enclosure Type: Default: *NONE*

NONE - NoneCOND - Conduit

11 Operator center: Honeywell TDC3000 OPER-CENT

Operator Center Type: Universal operator center or local center for one data hiway.Default: *UNIV*UNIV - Universal centerLOCAL - Local center

Operator CRT: Number of operator CRT (Cathode-Ray Tube Terminals), includeskeyboards

No. Hiway Gateways: Number of gateways for data hiways.Indicating CRT: Number of indicating CRT, no keyboard included.No. of Disk Drivers: Number of dual floppy disk drivers.No. Eng. Keyboard: Engineer’s keyboard for display.No. of LCN Cables: Number of local control network cables.History: History module for trend analysis. Default: *NONE*

HIST - Add history moduleNONE - No history module

Page 7: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-7

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Sensor Loop DescriptionsSensor Loop DescriptionsSensor Loop DescriptionsSensor Loop DescriptionsSensor Loop Descriptions

Pressure

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Pressure Gauge, field mounted:Sensing element types (default = ST):

11 pipe fittings to process (ST), P I LC nonegauge valves to process (FT)

Pressure Transmitter:12 field mounted, P I LP p

via pipe and tubing ICRC or or

standard or mircoprocessor R1R2 CC eR3

Pressure Controller: field mounted,14 pipe and tubing P IC LC p

Pressure Switch:15 field mounted, via pipe and tubing P A LP

or electricCC

Additional Control Valve:99 secondary control valve for adding P IC LP p

to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 8: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-8

© ICARUS Corporation, 1998. G2

ICARUS Reference

Differential Pressure

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Differential Pressure Gauge:16 connected to process via pipe and DP I LC none

tubing

Differential Pressure DP I LP p17 Transmitter: IC

connected to process via pipe and RC or ortubing R1

R2 CC estandard or mircoprocessor R3

Differential Pressure Switch:18 connected to process via pipe and DP A LP

tubing or electricCC

Additional Control Valve:99 secondary control valve for adding DP IC LP p

to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 9: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-9

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Temperature

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Thermocouple:21 with thermowell T CI LP

JI or noneJR CC

Temperature Transmitter23 with thermowell: T I LP

Sensing element types IC e(default = FS): RC or orThermocouple (TC), R1 pFilled system (FS), R2 CCResistance temperature detector (RT), R3Wet bulb temperature (WB)

standard or microprocessor

Dial Thermometer:25 with thermowell T I LC none

Temperature Controller:26 filled system, with thermowell T IC LC p

Testwell:27 thermowell and cap only T none LC none

Temperature Switch:28 with thermowell, field-mounted T A LP

or electricCC

Additional Control Valve:99 secondary control valve T IC LP p

for adding to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 10: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-10

© ICARUS Corporation, 1998. G2

ICARUS Reference

Flow

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Local Flow Meters:31 Sensing element types (default FG): F I LC none

Flow glass (FG),Rotameter (RT),Orifice plate (OP)

Flow Transmitter:34 Sensing element types F I LP e

(default = OP): IC orOrifice plate (OP) with RC or pdifferential pressure R1transmitter, R2 CCVortex meter (VX), R3Magnetic meter - standard or microprocessor (MG),Mass flow meter (MS),No sensing element/transmitterloop only (NS)

Flow Controller: orifice35 plate, field-mounted, F IC LC p

connected to process via pipe,valves, tubing

Flow Switch with orifice plate:37 Sensing element types (default FS): F A LP

Flow switch (FS), or electricFlow sensing and totalizing CC switch (TS)

Additional Control Valve:99 secondary control valve for adding F IC LP p

to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 11: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-11

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

LevelLevelLevelLevelLevel

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Level Indicators:41 Sensing element types (default LG): L I LC none

Level glass - reflex type (LG),Level gauge - reflex type with external standpipe (SP),Level indicator - bubble type (BB)

Level Controller:42 displacement type L IC LC p

Level Switch:44 Sensing element types (default (DS): L A LP

Level switch - fluids - displacement or electric type (DS), CCLevel switch - solids - paddle type (PD)

Level Transmitter:47 Sensing element types L I LP

(default = DS): IC eDisplacement type (DS), RC or orDifferential pressure - standard or R1 p mircroprocessor (DP), R2 CCTape/float (TF), R3Single point Ultrasonic level (UL),Nuclear level (NL)

Additional Control Valve:99 secondary control valve for adding L IC LP p

to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 12: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-12

© ICARUS Corporation, 1998. G2

ICARUS Reference

AnalyzersAnalyzersAnalyzersAnalyzersAnalyzers

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Analyzers:51 Sensing element types (default PH): A I LP

ph (PH), ICOxidation Reduction Potential RC or eORP (OR), R1Oxygen - up to 4 samples (O2), R2 CCBTU (BT), R3Density (DN),Consistency (CS)

Additional Control Valve:99 secondary control valve A IC LP p

for adding to another control loop or orCC e

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 13: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-13

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

SpeedSpeedSpeedSpeedSpeed

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Speed Indicating Transmitter:71 electronic, S I LP

non-contact type ICRC or eR1R2 CCR3

Speed Switch:72 S A LP electric

orCC

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 14: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-14

© ICARUS Corporation, 1998. G2

ICARUS Reference

Motion: Axial, Radial, VibrationMotion: Axial, Radial, VibrationMotion: Axial, Radial, VibrationMotion: Axial, Radial, VibrationMotion: Axial, Radial, Vibration

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Motion Transmitter - non contact type,73 (default AX): X I LP

Axial (AX), ICRadial (RD) RC or e

R1R2 CCR3

Vibration Switch:75 vibrating reed type X A LP

or electricCC

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 15: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-15

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

PositionPositionPositionPositionPosition

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Position Transmitter,76 (default VP): PN I LP

Variable position (VP), IC eOn/Off position (NF) RC or or

R1 pR2 CCR3

Position Switch:78 PN A LP electric

orCC

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 16: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-16

© ICARUS Corporation, 1998. G2

ICARUS Reference

WeightWeightWeightWeightWeight

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Load Cells:66 Sensing element options W I LP e

(Default = 4C): IC3 cell configuration (3C) RC or4 cell configuration (4C) R16 cell configuration (6C) R2 CC

R3

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

ConductivityConductivityConductivityConductivityConductivity

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Conductivity Transmitter:61 C I LP e

ICRC orR1R2 CCR3

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 17: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-17

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Hand (Manual) ActivationHand (Manual) ActivationHand (Manual) ActivationHand (Manual) ActivationHand (Manual) Activation

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Hand Regulator:81 field-mounted (pneumatic) H IC LC p

Manual Controller:82 panel-mounted, no input signal, H IC LP or CC e or p

output signal only

Manual Switch: panel-mounted83 (front of panel) H S LP or CC electric

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Field Mounted SolenoidField Mounted SolenoidField Mounted SolenoidField Mounted SolenoidField Mounted Solenoid

Sensor Process Panel Instrument SignalType Loop Description Variable Action Location TypeSymbol (1) (2) (3)

Solenoid:91 Field-mounted SL none LP or CC electric

(1) For panel action, panel option and control valve option, refer to the applicable section later in this chapter.

(2) Instrument Location:LC = local, on equipment or pipingLP = local panelCC = control center (analog or digital).

(3) Signal Type: e = electronic, p = pneumatic.

Page 18: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-18

© ICARUS Corporation, 1998. G2

ICARUS Reference

Panel Action DescriptionsPanel Action DescriptionsPanel Action DescriptionsPanel Action DescriptionsPanel Action Descriptions

Panel Action DefinitionSymbol

I Indicator:

field-mounted indicator if local to equipment (LC), or,

panel-mounted indicator (receiver type) if on local panel (LP) or in control center (CC)

IC Indicating Controller:

field-mounted indicating controller if local to equipment (LC), or,

panel-mounted indicating controller (receiver type) if on local panel (LP) or incontrol center (CC)

RC Recording Controller (LP or CC):

panel-mounted, one pen

Recorder (LP or CC):

R1 panel-mounted, one penR2 panel-mounted, two pensR3 panel-mounted, three pens

A Annunciator Point (LP or CC):activated by a field-mounted switch

S Switch: indicating, front-of-panel mounted (LP or CC)

Thermocouple-based Temperature Indicator, panel mounted (LP or CC):

CI complete with back-of-panel mounted EMF converter

JI multi-point

JR Thermocouple-based Temperature Recorder, multi-point, panel mounted (LP or CC)

Page 19: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-19

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Panel Option DescriptionsPanel Option DescriptionsPanel Option DescriptionsPanel Option DescriptionsPanel Option Descriptions

Panel Option DefinitionSymbol

A1 Panel alarm: one back-of-panel switch

A2 Panel alarm: two back-of-panel switches

CR Computation relay: +, -, X, /

SQ Square root function

FX Defined function of X

LR Limit regulation: high/low

ES Emergency shutdown (ESD)

BS Bias relay

Fisher Control Valve Information Fisher Control Valve Information Fisher Control Valve Information Fisher Control Valve Information Fisher Control Valve Information (All Country Locations)

Control Valve Size Range Body Type Actuator PositionerType

Globe < = 4 INCHES CE 585 3611JP6 - 8 INCHES ED 657 3582

Ball all sizes V100 1052 3610J

Butterfly all sizes 8532 1052 3610J

Page 20: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-20

© ICARUS Corporation, 1998. G2

ICARUS Reference

Control Valve OptionsControl Valve OptionsControl Valve OptionsControl Valve OptionsControl Valve Options

Type Definition

STD Standard control valve (default)

GLP Globe type positioning, usually sizes up to 8 INCH [200 MM]

BAP Ball type positioning, usually medium sizes up to 12 INCH [300 MM]

BUP Butterfly type position, usually large sizes from 3 INCH [75 MM]

BVO On/Off ball valve

SGO On/Off slide gate for solids handling

SGP Positioning slide gate for solids handling

DIV Diverter valve for solids handling

Note: The standard control valve is a variable composite of the other types depending on size as follows:

Type Size

Globe 0.5 - 4 INCH [12- 100 MM]Ball 6 - 12 INCH [150 - 300 MM]Butterfly > 12 INCH [>300 MM].

Fluid positioning control valves may be specified as line size or reduced size. The default size reductions areas follows:

Line size Control valve

0.5 - 4 INCH [12 - 100 MM] Same as line.6 INCH [150 MM] One size smaller than line.

8 - 12 INCH [200 - 300 MM] Two sizes smaller than line.14 - 24 INCH [350 - 600 MM] Three sizes smaller than line.

> 24 INCH [>600 MM] Four sizes smaller than line.

Transmitter TypeTransmitter TypeTransmitter TypeTransmitter TypeTransmitter Type

Type Definition

S Standard

M Microprocessor (Smart)

Page 21: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-21

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Overview of Instrumentation Report Details

Three-digit numbers refer to Instrumentation Codes of Account.Note:

Digital Analog

Instrumentation

Item Area Item Area

Panel,Panel Devices

620

Panel,Panel Devices

620

Panel, *Panel Devices

622, 623

FieldInstrumentation

610

FieldInstrumentation

610

Electronic Pneumatic Electronic Pneumatic

InstrumentSignal Wiring

636

PneumaticTubing

634

InstrumentSignal Wiring

636

PneumaticTubing

634

InstrumentSystem Testing

690

InstrumentSystem Testing

690

InstrumentElectrical

650

InstrumentSupport & Encl.

640

Final ControlElements

680

InstrumentElectrical

650

Final ControlElements

680

Material costs for back-of-panel and front-of-panel instrumentsare reported as Area costs only when instruments have beenspecified as being located at the Control Center.

*

InstrumentSupport & Encl.

640

Page 22: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-22

© ICARUS Corporation, 1998. G2

ICARUS Reference

Report Details for Analog/Electrical Instrumentation

Three-digit numbers refer to Instrumentation Codes of Account.Note:

InstrumentationAnalog/Electronic

Flow611

Pressure612

Level613

Analyzers615

Burner617

Temp614

Motion616

Orifice Plates618

Other619

Local Panels,Panel Devices

620

InstrumentSupport & Encl.

640

Final ControlElements

680

AreaDesign & Cost

Reporting

ItemDesign & Cost

Reporting

Instrument RunsInstrument Signal Wiring

636

Air SupplyPiping

631Instrument

Piping632

Terminations

633Pneumatic

Tubing634

M/C InstrumentWire637

T/C ExtensionWiring

638

Wire/Cable,Etc.651

Solenoids

653

ControlValves

681SafetyValves

682

RuptureDiscs683

Motor OperatedValves

684

DiverterValves

686

FieldInstrumentation

610

Local Panels, *Panel Devices

622, 623

InstrumentTesting

691InstrumentElectrical

650

I/PTransducer

659Material costs for back-of-panel and front-of-panel instrumentsare reported as Area costs only when instruments have beenspecified as being located at the Control Center.

*

= Multi Conductor= Thermocouple= Current to Pressure

M/CT/CI/P

Page 23: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-23

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Report Details for Analog/Electrical Pneumatic Instrumentation

Three-digit numbers refer to Instrumentation Codes of Account.Note:

Flow611

Pressure612

Level613

Analyzers615

Burner617

Temp614

Motion616

Orifice Plates618

Other619

Local Panels,Panel Devices

620

InstrumentSupport & Encl.

640

Final ControlElements

680

AreaDesign & Cost

Reporting

ItemDesign & Cost

Reporting

Air SupplyPiping

631

InstrumentPiping

632

PneumaticMulti-Tube

633

ControlValves

681SafetyValves

682

RuptureDiscs683

Motor OperatedValves

684

DiverterValves

686

FieldInstrumentation

610

Local Panels, *Panel Devices

622, 623

InstrumentTesting

691

Material costs for back-of-panel and front-of-panel instrumentsare reported as Area costs only when instruments have beenspecified as being located at the Control Center.

*

InstrumentationAnalog/Pneumatic

Instrument RunsPneumatic Tubing

634

= Multi Conductor= Thermocouple= Current to Pressure

M/CT/CI/P

Page 24: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-24

© ICARUS Corporation, 1998. G2

ICARUS Reference

Report Details for Digital/Electrical Instrumentation

Flow611

Pressure612

Level613

Analyzers615

Burner617

Temp614

Motion616

Orifice Plates618

Other619

Local Panels,Panel Devices

620

InstrumentSupport & Encl.

640

Final ControlElements

680

AreaDesign & Cost

Reporting

ItemDesign & Cost

Reporting

Instrument RunsInstrument Signal Wiring

636

Air SupplyPiping

631Instrument

Piping632

Terminations

633Pneumatic

Tubing634

M/C InstrumentWire637

T/C ExtensionWiring

638

Wire/Cable,Etc.651

Solenoids

653

ControlValves

681SafetyValves

682

RuptureDiscs683

Motor OperatedValves

684

DiverterValves

686

FieldInstrumentation

610

InstrumentTesting

691InstrumentElectrical

650

I/PTransducer

659

InstrumentationDigital/Electronic

Three-digit numbers refer toInstrumentation Codes of Account.

Note:

= Multi Conductor= Thermocouple= Current to Pressure

M/CT/CI/P

Page 25: Instrumentation - University of Western Ontarioinstruct.uwo.ca/engin-sc/cbe497/Doc/Icarus/ir21.pdf · Instrumentation plant bulks include cable, tube bundles, tray and panels. Description

21-25

G2 © ICARUS Corporation, 1998.

Chapter 21: Instrumentation

Report Details for Digital/Electrical Pneumatic Instrumentation

Flow611

Pressure612

Level613

Analyzers615

Burner617

Temp614

Motion616

Orifice Plates618

Other619

InstrumentSupport & Encl.

640

Final ControlElements

680

AreaDesign & Cost

Reporting

ItemDesign & Cost

Reporting

Air SupplyPiping

631

InstrumentPiping

632

PneumaticMulti-Tube

633

ControlValves

681SafetyValves

682

RuptureDiscs683

Motor OperatedValves

684

DiverterValves

686

FieldInstrumentation

610

InstrumentTesting

691

Instrument RunsPneumatic Tubing

634

InstrumentationDigital/Pneumatic