DataN
etSolution
WIRELE
SSINTELL
IGENTLOGGIN
GN
ETWORK
www.fo
urtec.co
m
DataNetisanessentialhardwareandsoftwaresolutionthatcan
empoweranyorganizationtomonitortheirenvironmentusingthe
ZigBeewirelessnetwork.
TheDataNetcomprehensivereal-timedataloggingsolutionis
directedbyevent-drivensecuritypolicies.DataNetdeliversatruly
worthydataloggingsolutionbyleveragingthepowerofZigBee
wireless,2.4GHztelemetryprotocol.Supportingupto65,000units
pernetwork,withfast,cable-freeinstallationforinstantsetup.
• Wirelessdataloggingforprocessing,transportationandstorage
• MultiplenetworkmanagementfromsingleworkstationorviaLANforlong rangemonitoring
• Internalsensorsforsite-specifichumidity/temperaturemonitoring
• Multiplemodelsmeasuring4to20mA,0to1V,PulseCounter,PT1002-wires, NTC,ThermocoupleJ,KandT,Contactinputs
• Fullyreliablereal-timewirelessmonitoringnetwork
• MultiplealarmsviaSMS,emailandexternalsiren
• Worldwidelicense-free2.4GHzband
• OperatingkeypadandLCDdisplay
• APIforintegratingDataNethardwarewithproprietarysystems
Wireless,multi-unitdataacquisition,delivering24/7real-timemonitoringforindustrialenvironments
WAREHOUSINGChemical,industrialandperishablesstorage
PHARMACEUTICALMonitoringenvironmentsinlabs,fridges,freezersandculturerooms
COLDSTORAGEOptimizingtemperatureinrefrigeratedwarehousing
HOSPITALSMedicalalertmonitoring,sterilization,bloodproductsstorageandtransport
COLDCHAINEnsuringqualityproductsthroughoutthecoldchainprocess
DataN
etSolution
WIR
ELESSINTELLIG
ENTLOGGIN
GN
ETWORK
The DataNet solution comprises a range of loggers measuring a variety of inputs, including internal temperature and humidity sensors. From 5-6 input models down to the more cost-effective single or dual input Mini DataNet models, we offer a comprehensive solution for every application.
TheDataNetmulti-unitdataacquisitionsolutionisgeared
towards24/7real-timedataloggingformissioncritical
organizations.TheDataNet’scomprehensiveonline
solutionisdirectedbyevent-drivensecuritypolicies.
Loggingunitsfunctioninawirelessmeshnetwork
configuration,allowingfor65,000unitsineachnetwork.
Thisenablesreal-timemonitoringofmultipletestpoints
inasingleoperation.
TheDataNetproductfamilysupportsonboard
temperatureandhumiditysensors,aswellasthe
followingindustrystandardinputs:4externalchannelsfor
4to20mA,0to50mV,0to1V,PT-100,Thermocouple,
Contact,PulseCounterandFrequency.
DataNetsystemoffersabroadselectionofloggermodels
meetingawidevarietyofindustryapplicationsneeds.
LCDScreen
MenuButton
Scroll/OnButton
MiniUSBConnector
ACSocket
DataLoggerExternalInputs(4)
Internalsensorhousing
12VExcitation
• DNR900 Receiver/Repeater –theheartofthesystemcontrolsandcollectsthe
datafromtheendunits.Alsosuitableforextendingthesystemrange.
• DNL910 and DNL920 –loggerswithinternaltemperatureand/orhumidity.
Supportsfourexternalinputs:4to20mA,0to1V,0to50mV,PT-1002wires,
Thermocouples(J,KandT),Contact,PulseCounterandFrequency
• DNL910 PA and DNL920 PA –loggerswithintegratedpoweramplifierfor
extendedrange.SamesupportedexternalandinternalsensorsasDNL910and
DNL920.
• DNR800 Mini Repeater –cost-effectiveunitforextendingthesystemrange.
• DNL804-BXT, DNL808-BXT, DNL810-BXT –cost-effectiveloggerssupporting
uptotwoinputs,measuringtemperature,humidityandcurrent(4-20mA).
IncludesuptofourAA3.6Vfor3-yearbatterylife.
DNL920 DNL910
DNL920PA
DNL910PA
DNR900Receiver
DNR800DNR900
DNL808-BXT
DNL804-BXT
DNL810-BXT
Data View Features
Real-timedatainmultipledisplays(Graph,Table,Statistics)
Sensor View
Real-timesensor-specificdataviewwithalarmstatus
Map View
• Internationaldateformat• Abilitytorenameeverylogger andexternalinput• MapViewdisplayingunit location,signalpathandsignal strengthtothePC
Alarm Features
Alarmlevelsetupwithemail&SMSnotifications.Fouralarmlevels,allowingforprogrammingofseparateparameters,includingalarmdelayandduration
DataSuiteSoftwareforDataNetSupported Operating Systems:Windows®XPSP3/Vista/7(32and64Bit)
Minimum Hardware Requirements:Pentium4,2GHzProcessororbetter,512MBRAM,250MBavailablediskspace
FDATitle21CFRPart11Compliant
The DataSuite Software provides security for your products with online monitoring and control of
multiple networks supporting the entire intelligent DataNet data logging solution via LAN.
DatPass
DatPassisauseradministrationsoftwarewhichsupportstheassignmentofpasswordsandoperatingprivilegesforallfourtecindustryapplicationsoftwareensuringCFRcompliancy.CFRisaFoodandDrugAdministration(FDA)issuedregulation(Title21CodeofFederalRegulations,Part11).
DatPass Audit Trail
ReportModule
TheReportmoduleprovidestheDataSuiteuserwithanintuitiveinterfaceforcreatingandgeneratingreportswhichhavemanyparametersgarneredfromtheDataNetunitsandsoftware.Eachreportcanbeemailedtoaselecteddistributionlist,atpre-definedtimeintervals,inPDFandExcelformat
Analysis Features
Dewpointanalysis,FOPasteurization,histogram,MKT,statisticswithexporttoExcelandCSVformats
Application Example – Medical Center
Receiver
Repeater
CONTROL CENTER
INPUT TYPES
DNL910, DNL920, DNL910-PA, DNL920-PA
4 to 20 mA• Range: 4to20mA• Resolution: 4.76μA• Accuracy: ±0.5%• Loopimpedance: 21Ω
0 to 50 mV• Range: 0to50mV• Resolution: 3μV• Accuracy: ±0.5%• Inputimpedance: 25MΩ• Maximumvoltage: 3.2V
0 to 1 V• Range: 0to1V• Resolution: 200μV• Accuracy: ±0.5%• Inputimpedance: 25MΩ• Maximumvoltage: 3.2V
Temperature PT-100 (2-wires)• Range:-200to400˚C• Resolution:0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to400˚C ±0.5% -60to60˚C ±0.3˚C
Temperature Thermocouple J• Range: -200to1,000˚C• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to1,000˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C
Temperature Thermocouple K• Range: -200to1,000ºC• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to1,000˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C
Temperature Thermocouple T• Range: -200to400˚C• Resolution: 0.1˚C• Accuracy: -200to-60˚C ±0.5% 60to400˚C ±0.5% -60to60˚C ±0.5˚C• Coldjunctioncompensationerror: ±0.3˚C
Contact (for Switch/Door Position)• Range: Open/Closed
Pulse Counter (input 4 only)• Optocouplerinput• Range: 1to65,536counts• Resolution: 1count• Frequencyrange: 0to4,000Hz• Inputsignal: 0to5V• Inputimpedance: 470Ω
Frequency (input 4 only)• Optocouplerinput• Range: 20Hzto4KHz• Inputsignal: 0to5V• Inputimpedance: 470Ω
Internal Temperature• Type: DNL910:PT-100 DNL920:Digital• Range: -20to50˚C• Resolution: 0.1˚C• Accuracy: DNL910:±0.3˚C DNL920:±0.5˚C
Internal Humidity (for DNL920)• Range: 5to95%• Resolution: 0.5%• Accuracy: ±3%at10to90% ±5%at5to10%and90to95%
DNL804-BXT, DNL808-BXT and DNL810-BXT
DNL804-BXT External Current Sensor• Range: 4to20mA• Resolution: 0.06°C1.16uA• Accuracy: 0.5%• Loopimpedance: 21Ω
DNL808-BXT External Temperature Sensor• Range: -50to150°C• Resolution: 0.06°C• Accuracy: -50to60˚C ±0.3˚C 60to150˚C ±0.5%
DNL810-BXT Internal RH/Temperature Sensors• Temprange: -20to50°C• Tempresolution: 0.04°C• Tempaccuracy: ±0.4°C• Humidityrange: 5to95%• Humidityresolution: 0.5%• Humidityaccuracy: ±3%
OUTPUTS
DNR900, DNL910, DNL920, DNL910-PA, DNL920-PA
External Power Excitation (transducers usage)• 12VDC@2A• Resetfuseoverload
Dry Contact Alarm Output• Opencollector• Closepositionresistance:50Ω• Max.Load:50mA,3VDC
DATANET LOGGER SAMPLING FEATURES
• Memorycapacity: ~59,000samples• Samplingrate: Onceeverysecondtoonce every18hours• Samplingresolution: 16-bit• Channelseparation: 80dB
DATANET RF NETWORK COMMUNICATION
• Frequency:2.4GHz• Unitspernetwork:65,000• Datarate:250Kbps• Fullmeshnetworkarchitecturesupported• 128-bitnetworksecurityencryption• Worldwidelicense-free• RFTransmission: DNL8xxandDNL9xx: 4dbm DNR900,DNL9xx-PA: 17dbm DNR800: 20dbm
DATANET HARDWARE SPECIFICATIONS
DNR900, DNL910, DNL920 and DNL9XX-PA
Display• 2-rowLCD• 16characterdisplay
Power Supply• Internalrechargeable4.8VNiMHbattery• Built-inbatterycharger• External12VDCinput
Operating Temperature Range• -20to50˚Cforallmodels• Wateranddustproof:IP54
DNR900 PC Communication• USB2.0compliance• MiniUSBtypeBcable
Casing• PlasticABSbox• Dimensions: 97x93x27mm• Weight: 200gr• Tableandwallmounting
DNL804-BXT, DNL808-BXT, DNL810-BXT
Power Supply• Removablebatterypacksupportingupto4xAA3.6V lithiumbatteries• Batterylife:Upto3yearsdependingonsamplingrate
Casing
Dimensions• DNL810-BXT:10.2x8.8x5.3cm(withouttheexternal antenna)• DNL804-BXTandDNL808-BXT:9x8.8x5.3cm (withouttheexternalantennaandstrainreliefadd-on)
Weight:• 137gnotincludingbatteries• 218gincludingfourbatteries• ExternalAntenna: 17.5g• Wallmounting
Operating Temperature Range• -30to75˚Cforallmodels(operatingattemperature closetoorbelowzeromayaffectbatterylife)• Wateranddustproof:IP54
GENERAL SPECIFICATIONS
Man Machine Interface• 2-buttonkeypad
Standards Compliance• CE,FCC,ICCanada• QuadBand:GSM-850/EGSM-900/ DCS-1800PCS-1900MHz• SupportsOpenAT®softwareplatform• InternalExpansionSocket(AES)interface• RS232SerialInterface• 12VDCexternalpowersupply
DATASUITE SOFTWARE FOR DATANET
• Windows®basedsoftware• Datadisplayedinnumericorgraphicaldisplayofall inputs• Onlineretrievalanddisplayofthecollecteddatain real-time• Definitionofcustomsensors• Fullloggercalibration• Documentationandfiling• OfflineReceiveralarmindication• Alarmlevelsongraphs• Exporttospreadsheets• Analyticalfunctions,forprofessionalanalysisofthe collecteddata• Manualbackupofcalibrationsettings• Over-the-airfirmwareupdate• Softwareintegrationwithrangeoffourtecdata loggers
SpecificationsLengthandTemperaturespecificationsareprovidedinMetricandCelsiusunits
©2012fourtec-FourierTechnologiesLtd.Allrightsreserved.fourtec-FourierTechnologiesLtd.logosandallotherfourtecproductorservicenamesareregisteredtrademarkortrademarksoffourtec-FourierTechnologiesLtd.Allotherregisteredtrademarksortrademarksbelongtotheirrespectivecompanies.P/NBK180,Rev6.12
www.fourtec.com//[email protected]
Aboutfourtec
fourtec–FourierTechnologiesLtd.isarecognizedleaderindata-loggingandmonitoringsolutionsforcontrolled
industrialenvironments,suchasfood,pharmaceutical,medical,storageandtransportationindustries.
Oursolutionsenableourcustomerstodeliverhigherqualityproducts,ensureconsumersafety,complywith
regulatoryrequirementsandincreaseprofitability.Innovation,expertiseandacommitmenttoqualityarethe
valuesthatdrivethedevelopmentandproductionofourproducts.
OrderingInformationPart Number (PN) Product Description
DATANET DEVICES
DNR900A Receiver/Repeater + universal power supply
DNL910A Temperature RF logger with 4 external inputs + universal power supply + calibration certificate
DNL910A-PA Temperature RF logger with built-in Power Amplifier & 4 external inputs + universal power supply + calibration certificate
DNL920A Temperature & Humidity RF logger with 4 external inputs + universal power supply + calibration certificate
DNL920A-PA Temperature & Humidity RF logger with built-in Power Amplifier and 4 external inputs + universal power supply + calibration certificate
DNR800A Mini Repeater with extended RF range + universal power supply
DNL804A-BXT 4 to 20 mA RF logger + external antenna + calibration certificate + extended battery pack
DNL808A-BXT External NTC 10KΩ RF logger(-50 to 150 °C) + NTC temperature probe (2.5 m cable) + external antenna + extended battery pack
DNL810A-BXT Temperature and Humidity RF logger + external antenna + extended battery pack
SENSORS
12753 PT-100 (-70 to 400 °C) 2-wire temperature sensor (2.5 m cable)
12752 PT-100 (-70 to 400 °C) 2-wire temperature sensor (4 m cable)
12751 PT-100 (-70 to 400 °C) 2-wire temperature sensor (6 m cable)
50116 PT-100 (-200 to 400 °C) 2-wire temperature sensor (2.5 m cable)
50165 Thermocouple Type K sensor, 500 mm cable with flat pin connector
DT043 Temperature (-40 to 60 C) and Humidity probe (3 m cable)
DT332 Replacement NTC 10KΩ (-50 to 150 °C) temperature probe (2.5 m cable) for DNL808
ACCESSORIES & SOFTWARE
50164 Quad Band GSM Modem (for DataSuite SMS alerts)
13825 External Siren + Strobe for DataSuite alarm notifications
13750 USB over IP Ethernet adapter
13129 Replacement standard external antenna for Mini DataNet units
13416 External 2.5 m antenna with magnet connector
13330 Mini USB communication cable for DNR900 (3 m cable)
11304 Internal battery pack for DNL9XX loggers
13806 AA 3.6 battery for Mini DataNet External Battery Pack
12928 2/3 AA 3.6 V battery for Mini DataNet logger
AD001 Replacement universal 110V/220V power supply
DataSuite-DN DataSuite Installation CD + mini USB 3m cable + single user license
DS-CFR-DN DatPass for DataSuite meeting 21 CFR Part 11 Compliancy. With DataSuite CFR and DatPass software +mini USB 3m cable + user licenses