Intensive Care Ventilator & Patient Monitor
Product Catalogue
www.mek-ics.com
Intensive Care Ventilator & Patient Monitor
Product Catalogue
02/03
MEK-ICS was established in 1998.
focus on life care,
have developed Bio-signal Modules,
Intensive Care Ventilator and Patient Monitor, Pulse Oximeter.
pursue more complete solution for Life care.
Intensive Care Ventilator & Patient Monitor
VentilatorMV2000 ���������������04MV2500 (Domestic Model) ��������04MC200 ����������������04
Patient MonitorMP1300 ���������������06MP1000NTP ��������������07MP800 ����������������08MP700 ����������������09MP600 ����������������09
Pulse OximeterMP110 Plus ��������������10MP111 ����������������10MP570T ���������������11
EtCO2 MonitorMP800C ���������������11
Phototherapy UnitMH200 ����������������12
Veterinary MonitorMP1000NTP Vet ������������13MP800 Vet ��������������13
Bio signal ModuleSpO2 ����������������14ECG �����������������15NIBP �����������������15
Intensive Care Ventilator & Patient Monitor 04/05
Intensive Care Ventilator
MV2000MV2500 (Domestic Model)
Specifications
MV2000 / MV2500
Wide Application Range Applications : Neonate and Pediatric to Adult Ideal Body Weight Setting : 3kg~150kg Tidal Volume : 5ml to 2500ml
Ventilation Mode (All in One) Breath Type : Volume & Pressure Control Ventilation Standard Mode : ACV, SIMV+PPS, CPAP+PPS Special Mode : NIV, t-Bilevel, PRVC
Apnea Back-up Ventilation, Emergency Auto
Ideal Body Weight Setting Automatic setting in all parameter by body weight Volume limitation by body weight : 15[ml/kg] × weight[kg] User selectable body weight factor : 5 ~ 15 ml/kg
Special Functions Graphic I : E Ratio ViewerFend%(Flexible Inspiration Flow Pattern)Built-in NebulizerUp to 72hours graphic and tabular trendEx-sense%(Adjustable expiratory sensitivity)En-sense%(Preventive solution for auto-trigger)
Ventilator SettingBreath Type Volume and Pressure Ventilation Mode ACV, SIMV, Spontaneous
Bi-Level, PRVC, NIV, AutoPositive Pressure SupportApnea Back-up ventilation
IBW 3kg ~ 150kgTidal volume 5ml ~ 2500 mlInspiratory pressure 5 ~ 80 cmH2OInspiratory pressure limit 3 ~ 80 cmH2O(PRVC mode)Pressure support 0 ~ 60 cmH2ORespiratory rate 2 to 120 BPMI:E ratio 10:1 - 1:99Inspiratory time 0.2 ~ 9.9 secPlateau time 0 ~ 2.0 secInspiratory rising time 0.1 ~ 0.5 secPEEP 0 ~ 45 cmH2OHigh PEEP 5 ~ 45 cmH2OLow PEEP 0 ~ 45 cmH2OHigh PEEP time 0.2 ~ 9.9 secLow PEEP time 0.2 ~ 24 secEx-sense%(adj. exp. sensitivity) 10 ~ 60%En-sense%(reduce auto-trigger) 10 ~ 60%F-end(Insp. Flow Pattern) 25 ~ 100%Inspiratory flow rate 1 ~ 180 lpmTrigger sensitivity Pressure (0.5 ~ 20 cmH2O)
Flow (0.5 ~ 20 lpm)O2 21 ~ 100%Ideal body weight factor 5 ~ 15 ml/kgSigh, Tidal volume x 1.5 Off, 1 ~5 BPMHumidification type HME, Heated humidifierAltitude -100 ~ 5000m
Other key and IndicatorsNebulizer 10 ~ 180 min. Auto & ManualInspiration pause Resistance, ComplianceExpiration pause Auto-PEEPManual inspiration Setting tidal volume100% O2 100% oxygen for 3 minutesKey lock Function key lock
Dimensions / WeightMain unit W33×D25×H40 cm 30kgDisplay monitor W48×D6×H28 cm 7kgMobile cart W48×D57×H77 cm 20kgCompressor W30×D43×H44 cm 30kgInspiratory limb connector:ISO22mm conical maleExpiratory limb connector:ISO22mm conical maleAir and Oxygen inlets:DISS male/female
Monitoring DataVentilation mode and Ideal Body WeightTotal Respiration RateVolume(Insp. Tidal, Exp. Tidal, Exp. Minute)Pressure(Peak, Mean, Pause, PEEP)Spontaneous Exp. Minute Volume, Spontaneous RateRapid Shallow Breathing IndexHigh PEEP and Low PEEP(Bi-level Mode)Dynamic ComplianceReal Time Flow Rate(Insp., Exp., End Expiratory)Peak Flow RateDelivered O2 %Graphic I:E ratio (I-Time/E-Time)Pressure, Flow, Volume CurvePressure-Volume loop curveFlow-Volume curve.72hours Graphic and Tabular trendRSBI(Rapid Shallow Breathing Index)P 0.1 measurementTi / Ttot RatioEvent logCompliance graphic
AlarmsHigh pressure, Low pressureHigh tidal volume, Low tidal volumeHigh minute volume, Low minute volumeHigh respiration rateApneaHigh PEEP, Low PEEPPower lossWall O2/Air low inlet pressureHigh O2. Low O2
Obstructed tubeAirway leakCircuit openVentilator in-operationAlarm silenceAlarm reset
Power input100 ~ 230 VAC, 50/60 Hz (Free voltage)12VDC 7A External power input12VDC 7A Internal battery operating, Max. 180 minutesPower consumption : 84W(main unit only)
Ventilator
Option (International Sale)
Touch Screen for MV2000• 12.1-inch TFT Color Display
• User selectable waveform colors
• User configuration waveform display
Air Compressor Unit
MC200• Available to install inside MV2000 moving cart
• Low vibration & Low noise below 50dB
• Smart protection for humidity & dust
• Enable to supply Max. 2 units of MV2000
Intensive Care Ventilator & Patient Monitor 06/07
Intensive Care Patient Monitor
MP1300Intensive Care Patient Monitor
MP1000NTP• 12.1” Touch screen TFT color LCD
• 8 waveform display
• ECG, RESP, SpO2, NIBP, 4-IBP, 2-Temp. EtCO2, Multi-Gas, Cardiac Output
• Full Arrhythmia analysis and ST segment analysis
• Save up to 30 event management
• Oxy-CRG for management of neonatal intensive care patients
• Virtual screen system for various viewing
• 72-hours tabular and graphic trend
• Selectable color configuration for all parameters
• 10.4” superior resolution TFT color LCD
• 7 waveform display
• ECG, RESP, SpO2, NIBP, 2-IBP, 2-Temp. EtCO2
• Full Arrhythmia analysis and ST segment analysis
• Save up to 30 event management
• Virtual screen system for various viewing
• 72-hours tabular and graphic trend
• Selectable color configuration for all parameters
Patient Monitor
DisplayDisplay 12.1” Color TFT LCDResolution 800 × 600 SVGA Trace line 8 waveform
ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s
Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysisHRV measurement
RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%Perfusion Index 0.05~20%PWV measurement
Multi Gas(Option)Parameters CO2, O2, N2O, Anesthetic Agent Gas
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean
Last 3 measurementAuto deflation pressure Adult 300 mmHg / Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.
Invasive blood pressureNumber of channel Max. 4-channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SPSensor 5uV/mmHg (Optional)Accuracy ±2%Biasing and Scaling Automatic for BP signal display
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)
EtCO2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpmAccuracy ±2 mmHg, 0~38 mmHg / ±5%, 39~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm Cardiac Output(Option)Method ThermodilutionCardiac Output range 0.1~15 LPMParameters CI, SV, SI, LVSW, LVSWI, RVSW, RVSWI,
SVR, SVRI, PVR, PVRIBlood temp. range 23 ~ 43°CInjactate temp. range 0 ~ 27°C
DisplayDisplay 10.4” Color TFT LCDResolution 800 × 600 SVGA Trace line 7 waveform
ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s
Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis
RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean
Last 3 measurementAuto deflation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.
Invasive blood pressureNumber of channel Max. 4-channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SPSensor 5uV/mmHg (Optional)Accuracy ±2%Biasing and Scaling Automatic for BP signal display
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)
EtCO2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpmAccuracy ±2 mmHg, 0~38 mmHg ±5%, 38~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm
Intensive Care Ventilator & Patient Monitor 08/09
Semi Modularized Patient Monitor
MP800(PAMO II)
Semi Modularized Patient Monitor
MP700(PAMO I)
• 6.4” high quality resolution TFT color LCD
• 3/5-lead ECG, RESP, SpO2, NIBP, TEMP.
• Arrhythmia Analysis, ST segment, Pacemaker detector
• Virtual screen system for various viewing
• 72hours tabular and graphic trend
• ECG lead auto detection (3 lead or 5 lead)
• Smart and Compact size monitor
• 3/5-lead ECG, SpO2, NIBP, TEMP.
• Arrhythmia Analysis, ST segment, Pacemaker detector
• Back light Blue LCD display
• 72hours trend of HR and the other vital signs value
• Option - 58mm Thermal Printer, LAN networking capacity
Central Monitoring System
MP600• Up to 32 bed patient monitor
• Easy user interface with pop-up menu
• 72 hours graphic trend for each patient
• Save up to 200,000 case alarm event at 60G HDD
• Various display selectable
• Arrhythmia and ST segment display and Analysis
• LAN network
DisplayDisplay 5.5” Blue LCDResolution 240 x 128 Trace line 2 waveformTrend 72hrs of all vital signs
ECG Channel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Dynamic range 10mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s
Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis
SpO2
Range 0 ~ 100%Mode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
Non-invasive blood pressureMeasurement range 0~300 mmHgAuto defleation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveAutomatic Measurement 1,2,3,5,10,20,30 minutes Cycles 1,2,4,6,8,10 hoursMeasurement time max. 40 sec.
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)
Patient Monitor
DisplayDisplay 6.4” Color TFT LCDResolution 320 × 240 VGA Trace line 2 waveformTrend 72hrs Graphic and Tabular
ECGChannel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s
Artifact recovery time<8sPacemaker detection/rejectionST segment analysisArrhythmia analysis
RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm min
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonate, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systolic, Diastolic, Mean
Last 3 measurementAuto deflation pressure Adult 300 mmHg Neonate 150 mmHgSTAT Mode 5~15 min. of consecutiveMeasurement time max. 40 sec.
Temperature (1-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)
Intensive Care Ventilator & Patient Monitor 10/11
Hand Held Pulse Oximeter
MP110 PlusHand Held Pulse Oximeter
MP111Pulse Oximeter
MP570T
• Small size and light weight (400g)
• Back-light blue LCD Display
• Alarm silence mode(30sec.)
• Fast set-up time
• Long battery operation time (8 hours)
• Performance elevated for Low perfusion patient and Neonate
• Small size and light weight (400g)
• Back-light blue LCD Display
• Alarm silence mode(30sec.)
• Fast set-up time
• Long battery operation time (8 hours)
• Performance elevated for Low perfusion patient and Neonate
• 72-hours PR, SpO2 trend display with measured time
• Compact and Deluxe
• Most critically ill patient, Neonate to Adult
• SpO2, Plethysmographic waveform, Pulse rate
• High performance in low perfusion & moving
• Long battery operation (4 hours)
• 120 hours trend/1 minute sacle
• PI(Perfusion index) display
• O2 monitoring
• Smart and compact size gas monitor
• 6.4” TFT color LCD
• EtCO2 +RESP, SpO2
• 72 hours tabular and graphic trend
• Virtual screen display
• Main/Side stream CO2 sensor
• High performance in low perfusion & patient moving
DisplayDisplay 128 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,
SpO2 wave, Battery indicatedBeep sound on/off, Alarm silence count down Alarm condition, pulse markError massage, Menu display
SpO2
Range 0 ~ 100%Pulse Rate 30 ~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
DisplayDisplay 128 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,
SpO2 wave, Battery indicatedBeep sound on/off, Alarm silence count down Alarm condition, pulse markError massage, Menu display
SpO2
Range 0 ~ 100%Pulse Rate 30~ 250 bpmMode Selection Adult, Neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
OptionTrend viewer program
DisplayDisplay 240 × 64 Mono LCDParameters Oxygen saturation and Pulse Rate,
SpO2 wave, PI(perfusion index) Battery indicatedBeep sound on/offAlarm silence count down Alarm condition, pulse markError massage, Menu display
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, Neonatal, Auto modeAccuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
OptionO2 sensor with cable
DisplayDisplay 6.4” Color TFT LCDResolution 320 × 240 VGA Trace line 2 waveformTrend 72hrs Graphic and Tabular
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpmMode Selection Adult, neonatal, Auto mode Accuracy Adult ±2%. for readings 70~100% ±3%. for readings 50~69% Neonate ±3%. for readings 70~100% Unspecified 0~49%
EtCO2(Option)Measurement range 0-99 mmHgAccuracy ±2 mmHg, 0~38 mmHg ±5%, 38~99 mmHgSampling rate 50ml/minRespiration rate range 2 ~ 150 bpm
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Resolution 0.2°CMeasurement range 0~50°CAccuracy ±0.4°C (15~34°C, 41~45°C) ±0.2°C (34~41°C)
Pulse Oximeter EtCO2 Monitor
Multi-Parameter Gas Monitor
MP800C
Intensive Care Ventilator & Patient Monitor 12/13
Phototherapy Unit
MH200Veterinary Monitor
MP1000NTP VetVeterinary Monitor
MP800 Vet
• Light weight & Compact size
• Special irradiance : 30uW/cm2/nm at 43cm
• Narrow spectrum
• Wave length : 450nm ± 5%
• Normal LED life time : 20,000 hours
• No thermal damage to patient
• 10.4” superior resolution TFT color LCD • 7 waveform display• ECG+Resp, SpO2, NIBP, 2-IBP, 2-Temp.• Full Arrhythmia analysis and ST segment analysis• Save up to 30 event management• Virtual screen system for various viewing• 72-hours tabular and graphic trend
• 6.4” high quality resolution TFT color LCD• 3/5-lead ECG, RESP, SpO2, NIBP, TEMP.• Arrhythmia Analysis and ST segment analysis• Pacemaker Detection• Virtual screen system for various viewing• 72hours tabular and graphic trend• ECG lead auto detection (3 lead or 5 lead)
Phototherapy Unit Veterinary Monitor
Light SourceLamp Blue LCDwavelength Peak between 450nm, ±5%Intensity 12 ~ 30 uw/cm2/nm(@43cm distance)Lamp life time 20000 hours min.
General- 100 ~ 240 VAC, 50/60 Hz (Free voltage)- Power consumption : 35W(main unit only)- Dimensions : W315 × D154 × H50 mm
ECGChannel 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%
RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpm
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpm
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systoric, Diastoric, Mean
Last 3 measurement
Invasive blood pressureNumber of channel Max. 2channelMeasurement range -50~300mmHgLabel ART, FEM, PA, CVP, LA, RA, ICP, SP
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Measurement range 0~50°C
Etco2(Option)Measurement range 0-99 mmHgRespiration range 0~150 bpm
ECGChannel 1 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Gain 2.5, 5, 10, 15, 20 mm/mVHeart rate 20 ~ 300bpm, ±2%
RespirationMathod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpm
SpO2
Range 0 ~ 100%Pulse Rate 25 ~ 250 bpm
Non-invasive blood pressureMeasurement technique OscillometricMeasurement range 0~300 mmHgDisplay parameters Systoric, Diastoric, Mean
Last 3 measurement
Temperature (2-Temperature option)Sensor YSI 400 series (Optional)Measurement range 0~50°C
Intensive Care Ventilator & Patient Monitor 14/15
Bio signal Module
Model Grade Description
MM101-T TTL Level Spo2, 2-Temp,2-Ibp (External circuit presented by MEKICS)MM101-S RS232C Level
MM102-T TTL Level Spo2, 2-Temp,2-Ibp, Cardiac output(External circuit presented by MEKICS)MM102-S RS232C Level
SpO2 Module
MM100 series
• Multi Functional Module
- Cardiac Output, SpO2, Temp, IBP
• Strongest to Motion Artifact
• Strongest to Low Perfusion
ECG Module
MM200 seriesNIBP Module
MM300 series
Pulse OximeterSpO2 0~100%Resolution 1%Accuracy ±2%, For Reading 70~100%
±3%, For Reading 50~69%Low Perfusion 0.2% ~ 20%Pulse Rate 20~250 BPMResolution 1 BPMAccuracy ±2%
Invasive Blood PressureNumber of channel 2 channelMeasurement range -50 ~ 300mmHgSensor 5uV/mmHg Accuracy +/-2%
TemperatureNumber of channel 2 channelMeasurement range 0~50°C (Resolution: 0.2°C)Accuracy +/-0.4°C (15~34°C, 41~45°C), +/-0.2°C (34~41°C)Sensor YSI400 Series or
Compatible sensor
Cardiac OutputMethod ThermodilutionCardiac output range 0.1~20 LPMBlood temp. range 23 ~ 43 °CInjectate temp. range 0 ~ 27 °CResolution Cardiac output : 0.1 LPM,
Temperature : +/-0.1°CAccuracy Cardiac output : ±5%,
Temperature : ±0.1°C, Injectate temperature : ±0.1°C
Catheters Edwards compatible(Model: 177f75, 177hf75, 774f75, 774hf75)
GeneralPower Source DC +7.5 ~ +9.0V , 200mA MaxDimensions MM102: W90 × D51 × H15 (mm),
Isolation B/D: W120 x D70 x H20 (mm)Interface RS-232C Baud Rate 19200BPS,
no parity, 8 Bit, 1 Stop bit standardSpO2, Pulse rate, Infra-red wave data, Status MassageStandard : TTL Level - 5V
OptionInterface Direct PC Interface of RS232 STD Level
- Nellcor Compatible Spo2 Sensor, Accessories - Y-Type Spo2 Sensor
- Extension Cable (D-sub type)
ECGChannel 2 or 3 channelsElectrode 3 or 5 electrodeLead 7 Lead (I, II, III, aVR, aVL, aVF, C)Dynamic range 10mVHeart rate 20 ~ 300bpm, ±2%Input signal range ±0.5mV ~ ±5mVDefibrillator Prodection<5s
Artifact recovery time<8sBand wide 0.5~40Hz, 0.5~80Hz, 0.05~40Hz,
0.05~80Hz , monitoring modeESU Protection Yes(@Max. 300W)Lead off detection Yes(LA, RA, LL, RL, V)Pacemaker detection/rejectionST segment analysis -2.0mV ~ +2.0mVArrhythmia analysis , PVC detection, Lead off detection
RespirationMethod Impedance for ECG Lead IIRespiration rate 2 ~ 150 bpmAccuracy ±1bpmImpedance range 100 ~ 2000 ohmsDetect sensitivity 0.5 ohm minSensitivity control 10% ~ 90%Frequency response 0.1 ~ 4Hz(-3dB)
GeneralCommunication RS-232C Baud Rate 115KBPS, no parity,
8 Bit, 1 Stop bit standard ECG Heart rate, QRS wave data, Status Massage, Arrhythmia Data, Respiration Rate
Power +7.5V(Single power source)Power Consumption < 2.5WDimensions W145 × D70 × H20 (mm)Operating Temperature Operating Temperature ~ 40°C (50~104°F) Operating Humidity Operating Humidity 10 ~ 90%
Non-invasive blood pressureMeasurement technique Oscillometric Measurement range 0~300mmHg
Accuracy ±2mmHg or ±2%Auto deflation pressure Adult 300mmHg
Neonate 150mmHgShut Down Pressure 330mmHg
GeneralCommunication RS-232C Baud Rate 19200BPS, no partity,
8 Bit, 1 Stop bit standardSystolic, Diastolic, Mean Pressure Result, Pressure, Event MessageStart, Stop, Setting Parameter, Debugging Instruction
Power 12V DC 10%, Ripple & Nosie 5% Max.Power consumption 7.2W Type, ±10%, 600mA
12V Type at InflationDimensions W110 × D82 × H40 (mm)
• Oscillometric / Step down deflation
• Adult/Neonate Mode
• Automatic, STAT Mode
• Reliability good material use
• Lowest Motor Pump Noise
• Self Leakage test Mode
• 2 Channel ECG Wave Form (5-Lead)
• 13 Arrhythmia Analysis / Pacemaker Detection
• ST segment analysis
• Impedance respiration wave form (Lead I or II)
• Strongest to Electrode offset potential
• Including Isolation Power and Communication (CF)