Date post: | 03-Jan-2016 |
Category: |
Documents |
Upload: | melina-hawkins |
View: | 227 times |
Download: | 7 times |
Interaction ionizing radiation with biological tissue. Basic dosimetry.
Nov. 1895 – Announces X-ray discovery
Jan. 13, 1896 – Images needle in patient’s hand
– X-ray used presurgically
1901 – Receives first Nobel Prize in Physics
– Given for discovery and use of X-rays.
Wilhelm Röntgen, Wurtzburg
Radiograph of the hand of Röntgen’s wife, 1895.
Röntgen detected: • No reflection• No refraction• Unresponsive to mirrors or lenses
His conclusions:
• X-rays are not an EM wave
• Dominated by corpuscular behavior
Röntgen’s Setup
Projection X-Ray
Disadvantage: Depth information lost Advantage: Cheap, simple
)z(f),,(μ densityelectron , zyx attenuation coefficient
Measures line integrals of attenuation )dlμ(od I I x,y,ze
Film shows intensity as a negative ( dark areas, high x-ray detection
Sagittal Coronal
Early Developments
• Intensifying agents, contrast agents all developed within several years.
• Creativity of physicians resulted in significant improvements to imaging.
- found ways to selectively opacify regions of interest
- agents administered orally, intraveneously, or via catheter
Later Developments
More recently, physicists and engineers have initiated new developments in technology, rather than physicians.
1940’s, 1950’s
Background laid for ultrasound and nuclear medicine
1960’s
Revolution in imaging – ultrasound and nuclear medicine
1970’s
CT (Computerized Tomography)
- true 3D imaging
(instead of three dimensions crammed into two)
1980’s
MRI (Magnetic Resonance Imaging)
PET ( Positron Emission Tomography)
Computerized Tomography (CT)
1972Hounsfield announces findings at British Institute of Radiology1979 Hounsfield, Cormack receive Nobel Prize in Medicine(CT images computed to actually display attenuation coefficient x,y
Important Precursors:1917 Radon: Characterized an image by its projections1961 Oldendorf: Rotated patient instead of gantry
),(),(ID yxμyx Result:
First Generation CT Scanner
Acquire a projection (X-ray)Translate x-ray pencil beam and detector across body and record output
Rotate to next angleRepeat translation
Assemble all the projections.
Reconstruction from Back Projection
1.Filter each projection to account for sampling data on polar grid 2. Smear back along the “line integrals” that were calculated by the detector.
Modern CT Scanner
From Webb, Physics of Medical Imaging
Computerized Tomography (CT), continued
Early CT Image Current technology
Exhalation
Inhalation
Nuclear Medicine- Grew out of the nuclear reactor research of World War II- Discovery of medically useful radioactive isotopes1948 Ansell and Rotblat: Point by point imaging of thyroid1952 Anger: First electronic gamma camera
a) Radioactive tracer is selectively taken up by organ of interest
b) Source is thus inside body!
c) This imaging system measures function (physiology)
rather than anatomy.
Nuclear Medicine, continuedVery specific in imaging physiological function - metabolism
- thyroid function- lung ventilation: inhale agent
Advantage: Direct display of disease process.Disadvantage: Poor image quality (~ 1 cm resolution)
Why is resolution so poor?Very small concentrations of agent used for safety.
- source within bodyQuantum limited:
CT 109 photons/pixelNuclear ~100 photons/pixel
Tomographic systems: SPECT: single photon emission computerized tomography
PET: positron emission tomography
Combined CT / PET Imaging
Necessary Probe Properties
Probe can be internal or external.
Requirements:
a) Wavelength must be short enough for adequate resolution.
bone fractures, small vessels < 1 mm
large lesions < 1 cm
b) Body should be semi-transparent to the probe.
transmission > 10-1 - results in contrast problems
transmission < 10 -3 - results in SNR problems
λ > 10 cm - results in poor resolution
λ < .01Å - negligible attenuation
Standard X-rays: .01 Å < λ < .5 Å
corresponding to ~ 25 kev to 1.2 Mev per photon
Necessary Probe Properties: Transmission vs. λ
Graph: Medical Imaging Systems Macovski, 1983
Probe properties of different modalities
NMR
• Nuclear magnetic moment ( spin)
• Makes each spatial area produce its own signal
• Process and decode
Ultrasound
• Not EM energy
• Diffraction limits resolution
• resolution proportional to λ