+ All Categories
Home > Documents > International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the...

International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the...

Date post: 27-Mar-2020
Category:
Upload: others
View: 7 times
Download: 0 times
Share this document with a friend
24
International Spec Series 6 kVA - 830 kVA, 50 Hz POWER SYSTEMS CATALOG 8 kW - 750 kW, 60 Hz
Transcript
Page 1: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

International Spec Series 6 kVA - 830 kVA, 50 HzPOWER SYSTEMS CATALOG 8 kW - 750 kW, 60 Hz

15-03517_IntlSpecA4.indd 1 3/2/16 11:19 am

Page 2: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

Critical power applications are part of every industry; protecting them starts with reliable KOHLER® generators, available in diesel, natural gas and LP gas configurations. Our diesel models deliver dependable power to a wide range of output requirements. From small-load residential and business to heavy industry, every KOHLER generator is engineered to provide maximum power, performance, flexibility and fuel efficiency.

Today, Kohler provides integrated solutions to streamline the specifying process. Our industrial generators are diesel-fueled models — ranging from 6 kVA to 3,300 kVA @ 50 Hz (8 kW to 3,250 kW @ 60 Hz) complete with electronic controls and automatic transfer switches. To help cater to unique installation environments, we also offer a range of accessories, including controls, silencers, enclosures, fuel tanks and block heaters.

Disclaimer: Information in this publication represents product data available at the time of print. Kohler reserves the right to change this publication and the products represented without notice and without any obligation or liability.

KOHLER POWER SYSTEMS Headquarters and Manufacturing – Kohler, WI

Headquarters EMEA

Headquarters Southeast Asia and Manufacturing – Singapore

Manufacturing Facility – India

Manufacturing Facility – China

Sales Offices, Dealers and Distributors

SDMO (Kohler-Owned) Headquarters and Three Manufacturing Facilities – France

Manufacturing Facility – Brazil

Sales Offices, Dealers, and Distributors

DEPENDABLE POWER AND PERFORMANCETESTED, TRIED AND PROVEN TO WORK.

2

15-03517_IntlSpecA4.indd 2 3/2/16 11:19 am

Page 3: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

Anybody can claim to offer an unrivaled level of support, but it is another thing to deliver on that promise. Today, Kohler distribution network spans across multiple sales offices in countries throughout the Asia Pacific region.

Unlike other generator manufacturers, Kohler certified distributors and dealers specialize in power. This means our service network can be called on for anything related to your generator and its components.

With Kohler, you enjoy world-class service and support from a global service network.

SERVICE AND SUPPORTTHE HELP YOU NEED. ANY TIME, ANYWHERE.

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 3

15-03517_IntlSpecA4.indd 3 3/2/16 11:19 am

Page 4: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

TOTAL SYSTEM INTEGRATION.EVERYTHING WORKS TOGETHER.

Reliability of power systems is critical. Your business depends on it. At Kohler, we build industrial power systems that are proven to work because total system integration is engineered in from the start.

For more than 90 years, Kohler has earned a global reputation as a pure power expert — in large part to our strict quality standards. Our power systems are equipped with Kohler innovation, including generators, transfer switches, switchgear and controllers. Enduring the industry’s toughest testing process, including transient power testing, cooling sound and more, every part is built to work with the entire system and perform in the most demanding environments before they are shipped out.

Our power systems are built for nearly every application, powering everything from gas stations to hotels and hospitals, as well as military operations and airports. So you can be rest assured that our products will work when you need them most.

KOHLER® GENERATOR8-3,250 kW diesel and 20-400 kW gas

TRANSFER SWITCHOpen, closed, programmed transition, bypass and service entrance

REMOTE ANNUNCIATORMonitors and tests your generator set and ATS from a remote location

PD-SERIES SWITCHGEARParallels multiple generators to each other or to the utility

DECISION-MAKER® CONTROLLERSKOHLER controls and diagnostics ensure reliable on-site power

WIRELESS MONITORMonitors your system’s performance around the clock

KOHLER MONITOR SOFTWAREProvides monitoring and adjustment of generator and ATS equipment

4

15-03517_IntlSpecA4.indd 4 3/2/16 11:19 am

Page 5: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

6-830 kVA 8-750 kW

COMPREHENSIVE AND RELIABLE RANGE FOR EVERY POWER REQUIREMENT

Reliable, compact, user-friendly and versatile, the International

Spec Series generators are built to offer dependable power for all

applications (simple to complex), including healthcare, data centres,

airports and more.

These diesel generators are available in a wide range of power

outputs, from 6 kVA to 830 kVA, and can be customized to your

specific needs.

They are compatible with a variety of additional options and

accessories that are offered to further enhance performance and

deliver the best user experience.

KOHLER DECISION-MAKER® CONTROLSAvailable with a variety of controls – basic, advanced and paralleling, dedicated to generator set applications for optimal performance

CIRCUIT BREAKEROffers protection and maintenance of generator set

INTEGRATED FUEL-TANKIntegrated with generator skid that provides plug-and-play mode for quick on-site set up

OPTIONS AND ACCESSORIESImproved alternators, heavy-duty air cleaners, enclosures, fuel tanks, block heaters, multiple circuit breakers, heat-hand protection (CE)^ and more (Refer to page 14 for more information)

^ For selected models only. Please check with your sales representative on availability

4

1

2

3

INTERNATIONAL SPEC SERIESINDUSTRIAL DIESEL GENERATORS

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 5

15-03517_IntlSpecA4.indd 5 3/2/16 11:19 am

Page 6: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

KK SERIES

THREE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

KK16H - 16 3.6 - - - - KDW1003-H 3 1.0 1.41 x 0.72 x 1.02 310 50

KK21H - 21 4.9 - - - - KDW1404-H 4 1.4 1.41 x 0.72 x 1.02 350 50

KK28H 28 22.4 7.5 - - - - KDW1603-H 3 1.7 1.70 x 0.90 x 1.12 500 100

KK9 8.1 8.9 1.9 KK9U 7.6 8.4 2.3 KDW1003 3 1.0 1.22 x 0.70 x 0.92 290 50

KK12 10.9 12 2.5 KK12U 10.5 11.6 2.9 KDW1404 4 1.4 1.41 x 0.72 x 1.02 340 50

KK16 15 16.5 3.7 KK16U 14.5 16 4.5 KDW1603 3 1.7 1.41 x 0.72 x 1.02 410 50

KK22 19.5 21.5 3.5 KK20U 18.2 20 4.1 KDI1903M 3 1.9 1.41 x 0.72 x 1.08 490 50

KK27 24.1 26.5 4.7 KK25U 23 25 5.5 KDI2504M 4 2.5 1.41 x 0.72 x 1.08 540 50

KK33 30 33 5.9 - - - - KDI2504TM-30 4 2.5 1.70 x 0.90 x 1.26 629 100

KK44 40 44 7.5 - - - - KDI2504TM-40 4 2.5 1.70 x 0.90 x 1.26 690 100

SINGLE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

- - - - KK9UM 8 8.8 2.3 KDW1003 3 1.0 1.41 x 0.72 x 1.02 330 50

KK10M 9 9.9 2.5 KK12UM 10.9 12 2.9 KDW1404 4 1.4 1.41 x 0.72 x 1.02 350 50

KK12M 10.7 11.8 3.7 KK16UM 14.5 16 4.5 KDW1603 3 1.7 1.41 x 0.72 x 1.02 440 50

KK17M 15.6 17.2 3.5 KK20UM 18.2 20 4.1 KDI1903M 3 1.9 1.41 x 0.72 x 1.08 530 50

(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V. (2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is

available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.

Open Version - KK16U Open Version - KK27

6

15-03517_IntlSpecA4.indd 6 3/2/16 11:19 am

Page 7: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

THREE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

KK16H - M126 50 1.75 x 0.78 x 1.23 480 93 25.6 - 79 66 - -

KK21H - M126 50 1.75 x 0.78 x 1.23 520 93 19.0 - 80 67 - -

KK28H - M127 100 2.08 x 0.96 x 0.75 750 230 30.7 - 83 71 - -

KK9 KK9U M125 50 1.48 x 0.76 x 1.03 390 - - - 67 54 74 64

KK12 KK12U M126 50 1.75 x 0.78 x 1.23 510 93 36.8 31.7 67 54 74 64

KK16 KK16U M126 50 1.75 x 0.78 x 1.23 580 93 25.1 20.7 74 61 79 69

KK22 KK20U M126 50 1.75 x 0.78 x 1.23 660 93 26.6 22.5 71 58 77 67

KK27 KK25U M126 50 1.75 x 0.78 x 1.23 710 93 19.8 16.7 76 64 78 68

KK33 - M127 100 2.08 x 0.96 x 0.75 883 230 39.0 - 75 63 - -

KK44 - M127 100 2.08 x 0.96 x 0.75 944 230 30.7 - 76 64 - -

SINGLE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

- KK9UM M126 50 1.75 x 0.78 x 1.23 500 93 - 40.4 - - 74 64

KK10M KK12UM M126 50 1.75 x 0.78 x 1.23 520 93 36.8 31.7 67 54 74 64

KK12M KK16UM M126 50 1.75 x 0.78 x 1.23 610 93 25.1 20.7 74 61 79 69

KK17M KK20UM M126 50 1.75 x 0.78 x 1.23 700 93 26.6 22.7 71 58 77 67

COMPACT POWERThe performances offered by KOHLER Diesel KDI engines ensure our generator sets boost a remarkable ratio of power to size. This means they can be made more compact, thereby reducing transport and storage costs. With optimized combustion, both the fuel consumption and pollutant levels are particularly low.

Soundproofed Version - KK9Soundproofed Version - KK27

9-44 kVA 8-25 kW

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 7

15-03517_IntlSpecA4.indd 7 3/2/16 11:19 am

Page 8: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

KM SERIES

THREE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

KM9H - 9 2.6 - - - - L2E-SDH 2 0.6 1.22 x 0.70 x 0.92 240 50

KM12H - 12 4.2 - - - - L3E-SDH 3 1.0 1.22 x 0.70 x 0.92 260 50

KM8 6.8 7.5 1.7 - - - - L3E-SD 3 1.0 1.22 x 0.70 x 0.92 280 50

KM12 10.5 11.5 2.5 KM11U 10.2 11.2 3.2 S3L2-SD 3 1.3 1.41 x 0.72 x 1.05 387 50

KM16 14.5 16 3.4 KM16U 14.5 16 4.2 S4L2-SD 4 1.8 1.41 x 0.72 x 1.05 406 50

KM22 20 22 4.7 KM20U 18.2 20 5.6 S4Q2-SD 4 2.5 1.70 x 0.90 x 1.12 549 100

KM33 30 33 6.0 KM30U 27 30 8.2 S4S-SD 4 3.3 1.70 x 0.90 x 1.14 670 100

KM44 40 44 7.3 KM40U 36 40 8.7 S4S-DT 4 3.3 1.70 x 0.90 x 1.22 680 100

SINGLE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

KM8HM - 7.5 2.6 - - - - L2E-SDH 2 0.6 1.22 x 0.70 x 0.92 220 50

KM11HM - 10.5 4.2 - - - - L3E-SDH 3 1.0 1.22 x 0.70 x 0.92 280 50

KM6M 5 5.5 1.7 KM8UM 6.8 7.5 2.2 L3E-SD 3 1.0 1.22 x 0.70 x 0.92 280 50

KM9M 7.8 8.6 2.5 KM11UM 9.1 10 3.2 S3L2-SD 3 1.3 1.41 x 0.72 x 1.05 396/417 50

KM12M 10.9 12 3.4 KM16UM 13.6 15 4.2 S4L2-SD 4 1.8 1.41 x 0.72 x 1.05 406 50

KM17M 15.5 17 4.7 KM20UM 18.2 20 5.6 S4Q2-SD 4 2.5 1.70 x 0.90 x 1.12 590 100

KM25M 22.7 25 6.0 KM30UM 22 24 8.2 S4S-SD 4 3.3 1.70 x 0.90 x 1.14 710 100

- - - - KM40UM 36 40 8.7 S4S-DT 4 3.3 1.70 x 0.90 x 1.22 656 100

(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is

available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.

Open Version - KM20 Open Version - KM44

8

15-03517_IntlSpecA4.indd 8 3/2/16 11:19 am

Page 9: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

THREE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

KM9H - M125 50 1.48 x 0.76 x 1.03 360 93 35.8 - 79 65 - -

KM12H - M125 50 1.48 x 0.76 x 1.03 380 93 22.1 - 80 66 - -

KM8 - M125 50 1.48 x 0.76 x 1.03 390 ConsultFactory

ConsultFactory - 71 57 - -

KM12 KM11U M126 50 1.75 x 0.78 x 1.23 530 93 37.2 29.1 71 58 73 63

KM16 KM16U M126 50 1.75 x 0.78 x 1.23 554 93 27.4 22.1 72 72 74 64

KM22 KM20U M127 100 2.08 x 0.96 x 1.42 780 230 48.9 41.1 70 58 75 65

KM33 KM30U M127 100 2.08 x 0.96 x 1.42 900 230 38.3 28.0 74 62 76 66

KM44 KM40U M127 100 2.08 x 0.96 x 1.42 920 230 31.5 26.4 74 62 79 69

SINGLE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

KM8HM - M125 50 1.48 x 0.76 x 1.03 340 93 35.8 - 79 65 - -

KM11HM - M125 50 1.48 x 0.76 x 1.03 400 93 22.1 - 82 68 - -

KM6M KM8UM M125 50 1.48 x 0.76 x 1.03 390 ConsultFactory

ConsultFactory

ConsultFactory 70 57 78 68

KM9M KM11UM M126 50 1.75 x 0.78 x 1.23 544/565 93 37.2 29.1 71 58 73 63

KM12M KM16UM M126 50 1.75 x 0.78 x 1.23 630 93 27.4 22.1 72 59 75 65

KM17M KM20UM M127 100 2.08 x 0.96 x 1.42 820 230 48.9 41.1 70 58 75 65

KM25M KM30UM M127 100 2.08 x 0.96 x 1.42 940 230 38.3 28.0 74 62 76 66

- KM40UM M127 100 2.08 x 0.96 x 1.42 886 230 - 26.4 - - 79 69

6-44 kVA 10-40 kW

OPTION DETAILSKohler offers an optional double wall base frame that allows prolonged run time. With its double wall, the environment is protected against any possible fuel leak. It is the ideal option for use in isolated areas.

Soundproofed Version - KM33Soundproofed Version - KM9H

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 9

15-03517_IntlSpecA4.indd 9 3/2/16 11:19 am

Page 10: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

KD SERIES

THREE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

KD22 20 22 5 KD20U 18.2 20 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750/709 100

KD33 30 33 5 KD30U 25 28 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750 100

KD44 40 44 7.5 KD40U 36 40 8.7 3029TFS29 3 2.9 1.70 x 0.90 x 1.22 820 100

KD66 60 66 12 KD60U 55 60 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 995 180

KD77 70 77 12 KD70U 64 70 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 1128/1070 180

KD88 80 88 14 KD80U 73 80 16 4045TF220 4 4.5 1.87 x 0.99 x 1.36 1088/1070 180

KD110 100 110 16.5 KD100U 91 100 19 4045HF120 4 4.5 1.95 x 1.08 x 1.33 1187 190

KD130 120 132 18.5 KD120U 106 117 24 6068TF220 6 6.7 2.37 x 1.11 x 1.48 1498 340

KD165 150 165 25 KD150U 137 150 29 6068HF120-153 6 6.7 2.37 x 1.11 x 1.48 1578 340

KD200 182 200 31.3 KD175U 159 175 36.1 6068HF120-183 6 6.7 2.37 x 1.11 x 1.48 1730 340

- - - - KD200U 182 200 36.9 6068HF475 6 6.7 2.40 x 1.11 x 1.48 1790 340

KD220C2 200 220 34 - - - - 6068HFS77 6 6.7 2.40 x 1.11 x 1.48 1790 340

KD250 227 250 35.9 - - - - 6068HFS55-228 6 6.7 2.40 x 1.11 x 1.54 1800 340

SINGLE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230 V Specifications, 60 Hz, 240 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

- - - - KD20UM 18.2 20 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 750 100

- - - - KD30UM 20.4 22.4 6.5 3029DFS29 3 2.9 1.70 x 0.90 x 1.22 800 100

- - - - KD40UM 36 40 8.7 3029TFS29 3 2.9 1.70 x 0.90 x 1.22 786 100

- - - - KD60UM 55 60 14.5 4045TF120 4 4.5 1.87 x 0.99 x 1.36 1187 190

(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is

available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.

Open Version - KD88 Open Version - KD110

10

15-03517_IntlSpecA4.indd 10 3/2/16 11:19 am

Page 11: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

THREE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame

Enclosures with 48-hour

Tank

Sound Levels, 50 Hz

Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

Tank, L dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

KD22 KD20U M127 100 2.08 x 0.96 x 1.42 980/930 230 46.0 35.4 420 75 62 78 68

KD33 KD30U M127 100 2.08 x 0.96 x 1.42 980 230 46.0 35.4 420 74 62 78 68

KD44 KD40U M127 100 2.08 x 0.96 x 1.42 1040 230 30.7 26.4 420 74 62 77 67

KD66 KD60U M128 180 2.30 x 1.06 x 1.68 1405 390 32.5 26.9 700 73 61 77 67

KD77 KD70U M128 180 2.30 x 1.06 x 1.68 1548/1476 390 32.5 26.9 700 74 62 77 67

KD88 KD80U M128 180 2.30 x 1.06 x 1.68 1508/1476 390 27.9 24.4 700 76 64 83 73

KD110 KD100U M129 190 2.55 x 1.15 x 1.68 1587 505 30.6 26.6 825 78 66 80 70

KD130 KD120U M226 340 3.51 x 1.20 x 1.83 2088 868 46.9 36.2 1630 75 64 80 69

KD165 KD150U M226 340 3.51 x 1.20 x 1.83 2168 868 34.7 29.9 1630 75 64 80 69

KD200 KD175U M226 340 3.51 x 1.20 x 1.83 2320 868 27.7 24.0 1630 76 65 80 69

- KD200U M226 340 3.51 x 1.20 x 1.83 2390 868 - 23.5 1630 - - 80 70

KD220C2 - M226 340 3.51 x 1.20 x 1.83 2390 868 25.5 - 1630 77 66 - -

KD250 - M226 340 3.51 x 1.20 x 1.83 2400 868 24.2 - 1630 82 71 - -

SINGLE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

- KD20UM M127 100 2.08 x 0.96 x 1.42 980 230 - 35.4 - - 78 68

- KD30UM M127 100 2.08 x 0.96 x 1.42 1020 230 - 35.4 - - 78 68

- KD40UM M127 100 2.08 x 0.96 x 1.42 1016 230 - 26.4 - - 77 67

- KD60UM M129 190 2.55 x 1.15 x 1.68 1577 390 - 26.9 - - 77 67

OPTION DETAILSKohler offers an optional base frame with 48-hour tank. For maximum run time, opt for the double wall base frame with a large capacity integrated fuel tank that is idea for isolated areas. This option combines the need for autonomy with security, making it possible for all of the generator set’s fluids to be held.

Soundproofed Version - KD200Soundproofed Version - KD100U

with optional 48-hour tank

20-250 kVA 18-200 kW

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 11

15-03517_IntlSpecA4.indd 11 3/2/16 11:19 am

Page 12: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

KV SERIES

THREE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

- - - - KV250U 217 239 45.7 TAD734GE 6 7.2 2.90 x 1.30 x 1.59 2260 390

KV275C2 250 275 42.6 - - - - TAD734GE 6 7.2 2.90 x 1.30 x 1.59 2200 390

KV350C2 318 350 48 KV300U 273 300 54 TAD1341GE 6 12.8 3.16 x 1.34 x 1.76 3110 470

KV400C2 352 387 58 KV350U 319 350 69 TAD1342GE 6 12.8 3.16 x 1.34 x 1.76 3060 470

KV440C2 400 440 63.3 KV400U 364 400 72.4 TAD1344GE 6 12.8 3.16 x 1.34 x 1.81 3110 470

KV500C2 455 500 69.2 - - - - TAD1345GE 6 12.8 3.16 x 1.34 x 1.81 3250 470

KV550C2 500 550 75.4 KV500UC2 455 500 88.8 TAD1641GE 6 16.1 3.47 x 1.50 x 2.04 3620 500

- - - - KV550UC2 500 550 97.1 TAD1642GE 6 16.1 3.47 x 1.63 x 2.10 3650 610

KV650C2 591 650 85.2 - - - - TAD1642GE 6 16.1 3.47 x 1.63 x 2.10 3780 610

KV700C2 650 700 94.5 KV600UC2 545 600 105.7 TWD1643GE 6 12.8 3.47 x 1.63 x 2.05 4020 610

Open Version - KV500C2 Soundproofed Version - KV440C2

250-700 kVA 217-600 kW

THREE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

- KV250U M227 390 4.00 x 1.38 x 2.15 3190 950 - 20.8 - - 84 74

KV275C2 - M227 390 4.00 x 1.38 x 2.15 3130 950 22.3 - 78 67 - -

KV350C2 KV300U M228 470 4.48 x 1.41 x 2.43 3670 1368 28.5 25.3 77 67 85 75

KV400C2 KV350U M228 470 4.48 x 1.41 x 2.43 4170 1368 23.6 19.8 77 67 86 76

KV440C2 KV400U M229 500 5.03 x 1.56 x 2.44 4080 1368 21.6 18.9 78 68 89 79

KV500C2 - M228 470 4.48 x 1.41 x 2.43 4360 1368 19.8 - 78 68 - -

KV550C2 KV500UC2 M229 500 5.03 x 1.56 x 2.44 4870 1770 23.5 19.9 76 66 85 75

- KV550UC2 M230 610 5.03 x 1.69 x 2.66 5146 1950 - 20.1 - - 92 82

KV650C2 - M230 610 5.03 x 1.69 x 2.66 5300 1950 22.9 - 80 70 - -

KV700C2 KV600UC2 M230 610 5.03 x 1.69 x 2.66 5550 1950 20.6 18.4 85 75 89 79

(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity is

available for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.

12

15-03517_IntlSpecA4.indd 12 3/2/16 11:19 am

Page 13: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

KH SERIES

THREE-PHASE SPECIFICATIONS - Open Version

Specifications, 50 Hz, 230-400 V Specifications, 60 Hz, 277-480 V General Specifications

Generator Set

Model(1)

kVA Fuel Consumption at 3/4 Load,

L/h

Generator Set

Model(2)

kWe Fuel Consumption at 3/4 Load,

L/h

Engine Open Version(5)

Prime Power(3)

Standby Power(4)

Prime Power(3)

Standby Power(4) Engine Type Cyl CC, L Dimensions,

L x W x H, mWeight,

kg(6)Fuel

Tank, L

KH275 250 275 43.6 - - - - P126TI 6 11.1 2.90 x 1.30 x 1.67 2340 390

KH300 273 300 43.6 KH250U 227 250 52.3 P126TI 6 11.1 2.90 x 1.30 x 1.67 2410 390

KH330 300 330 47.0 KH300U 273 300 56.0 P126TI-II 6 11.1 3.16 x 1.34 x 1.59 2570 470

KH440 400 440 65.1 KH400U 364 400 74.7 P158LE 8 14.6 3.47 x 1.50 x 1.83 2910 500

KH550 500 550 83.4 KH500U 449 494 92.9 DP158LDF 8 14.6 3.47 x 1.50 x 1.82 3220 500

KH630 573 630 94.2 KH550U 500 550 106.6 DP180LA 10 18.3 3.47 x 1.53 x 2.16/1.97 3700/3465 610

KH700 631 694 103.8 KH600U 542 596 114.2 DP180LB 10 18.3 3.47 x 1.53 x 2.16 3700 610

KH830 750 825 119.1 KH750U 682 750 134.4 DP222LC 12 21.9 3.47 x 1.53 x 2.85 4080 610

Soundproofed Version - KH600UOpen Version - KH440

250-830 kVA 227-750 kW

THREE-PHASE SPECIFICATIONS - Soundproofed Version

Generator Sets Standard Enclosures Enclosures with Double Wall Base Frame Sound Levels, 50 Hz Sound Levels, 60 Hz

50 Hz 60 Hz Type Fuel Tank, L

Dimensions, L x W x H, m

Weight, kg

Fuel Tank, L

50 Hz, h Maximum Run Time

60 Hz, h Maximum Run Time

dB(A) @ 1m

dB(A) @ 7m

dB(A) @ 1m

dB(A) @ 7m

KH275 - M227 390 4.00 x 1.38 x 2.15 3190 950 21.8 - 83 73 - -

KH300 KH250U M227 390 4.00 x 1.38 x 2.15 3260 950 21.8 18.2 85 75 92 78

KH330 KH300U M228 470 4.48 x 1.41 x 2.43 3670 1368 29.1 24.4 81 71 85 75

KH440 KH400U M229 500 5.03 x 1.56 x 2.44 4090 1770 27.2 23.7 85 75 89 79

KH550 KH500U M229 500 5.03 x 1.56 x 2.44 4262 1770 21.2 19.0 84 74 90 80

KH630 KH550U M230 610 5.03 x 1.69 x 2.66 5381/5146 1950 20.7 18.3 88 78 92 82

KH700 KH600U M230 610 5.03 x 1.69 x 2.66 5381 1950 18.8 17.0 88 78 92 82

KH830 KH750U M230 610 5.03 x 1.69 x 2.66 5670 1950 16.4 14.5 88 78 88 78

(1) Also available in the following voltages: 240/415 V, 220/380 V, 127/220 V, 115/220 V.(2) Also available in the following voltages: 254/440 V, 127/220 V, 120/208 V.(3) Prime power in direct current for an unlimited number of annual operating hours in variable load applications, in accordance with IS08528-1, a 10% overload capacity isavailable for a period of 1 hour every 12-hour period of operation, in accordance with IS03046-1.(4) Emergency standby power available for supplying emergency power in variable load applications in accordance with IS08528-1, no overload available for this service.(5) The dimensions and weights apply to an open generator set without options.(6) Dry weight, without fuel.

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 13

15-03517_IntlSpecA4.indd 13 3/2/16 11:19 am

Page 14: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

GENERATOR SETS

MODULAR GENERATOR SETS, AN ADAPTED RESPONSE

For each of its generator sets, Kohler offers a large range of options to facilitate maintenance operations, enhance user

safety and provide solutions for specific requirements or unusual environments.

OPTION SPECIFICATIONS BY RANGE

KK Series KM Series KD Series KV Series KH Series

Protection of hot parts CEL02 CEL02 CEL02 CEL02 CEL02

Diesel separator pre-filter FD05 FD05 • • FD05

Battery isolating switch EN16 EN16 EN16 EN16 EN16

Automatic pack CA303/CM403 CA303/CM403 CA303/CM403 CM403/CM404 CM404

Electronic control EN01 EN01 EN01 • •

Automatic filling kit FD08(1) FD08(1) FD08(1) FD08(1) FD08(1)

Drainage pump EN04 EN04 EN04 • EN04

Analog measurements display CA307/CM407 CA307/CM407 CA307/CM407 • •

Oversized alternator X AO001B(2) AO001B(3) AO001B(4) AO001B(5)

Air discharge duct CN03 CN03 CN03 CN03 CN03

9dB(A) silencer in open version •(6) •(6) •(6) •(6) •(6)

High run time, double wall base frame FD02* FD02* FD02 FD02 FD02

Base frame with 48-hour tank X X FD03 X X

40dB(A) silencer EN09 EN09 EN09 EN09 EN09

• Standard X: Not available. CEL02: option code* for all generator sets except for M125 enclosures(1) Not possible on 48-hour and double wall base frame(2) Option not available for 3000 rpm and KM30UM, KM40U, KM40UM and KM44 generator sets(3) Option not available for KD20UM, KD30UM, KD40U, KD44, KD70U, KD80U and KD88 generator sets and on the soundproofed version of the KD220C2(4) Option not available on the soundproofed versions of KV600UC2 and KV700C2 sets(5) Option not available for the KH700 and on the soundproofed versions of the KH500U, KH550 and KH600U sets(6) 29 dB(A) and 40 dB(A) silencer available as an option

ANALOG MEASUREMENTS DISPLAY (CA307/CM407)This option enables the oil pressure and the water temperature to be displayed on the APM303 or DEC4000 screen. In some cases, this is on an additional display.

AIR DISCHARGE DUCT (EN12/EN08/EN09)Metal elbow-shaped box section which enables the air to be discharged from the top of the enclosure towards the front of the generator set.

BATTERY ISOLATING SWITCH (EN16)Battery isolator rotary handle for easy isolation of the battery during generator set storage.

1 2 3

2 31

14

15-03517_IntlSpecA4.indd 14 3/2/16 11:19 am

Page 15: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

PROTECTION FOR HOT PARTS (CEL02)Protective grille for hot parts (exhaust manifold) on the diesel engine and rotating parts. This option ensures the user's safety during maintenance operations.Mandatory option within the European community (European directive).

OVERSIZED ALTERNATOR (AO001B)For use under heavy electrical or climate constraints, this option allows greater operating flexibility for a better guarantee of performance.

DRAINAGE PUMP (EN04-EN05)Manual oil drainage pump for easier servicing of the generator set during maintenance operations. Standard option on enclosed generator sets.

SILENCER ON OPEN VERSIONFor "open" version generator sets, a choice of 3 noise reduction levels is available (9dB(A), 29dB(A), 40dB(A)), to meet the constraints of various installations.

AUTOMATIC PACK (EN20)This includes a preheating resistor and a battery charger. It is an engine preheating device which uses an electrical resistor. Preheating is self-adjusting up to 200 KVA and thermostat-controlled for outputs above this. This option is ideal for generator sets used as back-up. It allows the coolant to be maintained at a temperature of 40°C to facilitate emergency start-up and save time when

commissioning the generator set.

DIESEL SEPARATOR PRE-FILTER (FD05)This is a pre-filter enabling water contained in diesel to be removed, thereby improving the engine's protection.

FILTER WITH INTERCHANGEABLE CARTRIDGE (EN02)Dry air filters with removable and interchangeable cartridges for dusty environments which can be removed and cleaned with blown air, if required.This option is required when the generator set is used in dusty environments.

AUTOMATIC FILLING KIT (FD08)This is an automatic kit for filling the tank from an external storage tank.It includes:- An electric pump with automatic control governed by a gauge with level

contacts- A manual back-up pump

Extended use is possible without having to top up the diesel. This is particularly well suited for use in isolated areas.

ELECTRONIC CONTROL (EN01)Electronic speed regulator with control unit enabling precise control of speed, and therefore the frequency, to +/- 1%. This regulator is factory fitted as standard on some engines. This option allows the quality of the signal to be improved for better operation of sensitive equipment.

4

4

5

5

6

6

7

7

8

89

9

STANDARD FEATURES AND OPTIONS

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 15

15-03517_IntlSpecA4.indd 15 3/2/16 11:19 am

Page 16: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

SOUND ENCLOSURESKEEPING THE NOISE IN.

Built for reliability with self-diagnostic features, Kohler generator sets

come equipped with sound enclosures and integrated fuel tanks.

GENERAL SPECIFICATIONS

• Assembled soundproofing enclosures

• Kohler cream beige standard colour

• Rust-resistance : Electro-galvanized steel panels coated with

heat-hardening powder based on polyester resin as a form of

rust protection.

• High corrosion resistance for enclosure parts and fixtures

• Acoustic sound treatment : Soundproofing and fire-retardant

foam between 20-50mm thickness

• Silent operation: High priority on noise reduction and conforms

to 2000/14/EC noise emission standards

• Modularity: Modular design without complex installation;

maintenance and re-ordering of components now made

simpler and hassle-free

• Integrated fuel tank in generator skid

• Power circuit break

PLUG-AND-PLAY − No need for complex installation and

messy cabling− Shipped ready-to-use, ensuring seamless

and efficient integration into your power system

MOBILITY − Availability of lifting and handling points

to facilitate easy transportation− Minimal effort in installation required− Rapid deployment when rendering

back-up power

SILENT OPERATION − Sound-attenuating enclosures that are

quiet and rigorously tested

OUTDOOR INSTALLATION − Allow for more productive use of space

with outdoor installation− Cost-savings

16

15-03517_IntlSpecA4.indd 16 3/2/16 11:19 am

Page 17: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

STANDARD FEATURES AND OPTIONS

This chart shows option codes (examples: Sim, EN04, TR31, etc.). Feature codes refer to specific option descriptions

but are not part numbers for ordering purposes. Contact your authorized distributor for ordering options for a given

generator set.

Enclosures

M125 M126 M127, M128, M129 M226 M227, M228,

M229 M230

General Specifications

Assembled soundproofing enclosure Sim Sim Sim Sim Sim Sim

Non-assembled soundproofing enclosure (supplied as a kit)(1) N/A Sik Sik N/A N/A N/A

Kohler cream beige standard color Standard Standard Standard Standard Standard Standard

Special color (lead time 8 weeks) CN08 CN08 CN08 CN08 CN08 CN08

Electrogalvanized steel panels before paint application protected by a rust-resistant polyester powder coat Standard Standard Standard Standard Standard Standard

Dichromate galvanized hardware and stainless steel rivets, polyamide or anodized aluminum alloy hinges, seals provided by flexible joints between the body work components

Standard Standard Standard Standard Standard Standard

Soundproofing foam between 20-50 mm thick Standard Standard Standard Standard Standard Standard

Bulk tank on day service tank N/A N/A N/A FD04 FD04 FD04

Fluid recovery tank Standard Standard Standard N/A N/A N/A

High containment double wall chassis N/A FD02 FD02 FD02 FD02 FD02

Safety

Lockable doors with a unique key Standard Standard Standard Standard Standard Standard

Lockable control unit porthole Standard Standard Standard Standard Standard Standard

Emergency stop button installed on outside of enclosure Standard Standard Standard Standard Standard Standard

Access to diesel, oil and battery behind lockable doors Standard Standard Standard Standard Standard Standard

Protective guard for rotating parts Standard Standard Standard Standard Standard Standard

Exhaust integrated into the enclosure Standard Standard Standard Standard Standard Standard

Horizontal exhaust discharge hood CN03 CN03 CN03 CN03 CN03 CN03

Remote connection terminal block for armored cables N/A CN06 CN06 CN06 CN06 N/A

Socket kit, 400-volt, 3-phase, plus neutral(2) CN04 CN04 CN04 N/A N/A N/A

Handling

Lifting ring (number of points) 1 1 1 1 2 2

Single base panel N/A N/A N/A CN05 CN05 CN05

Maintenance

Access doors on each side (number) 2+1 2+1 2+1 2+2 2+2 2+2

Oil drain pump EN04 EN04 EN04 EN04 EN04 EN06

Electric control unit accessible via a door Standard Standard Standard Standard Standard Standard

Trailers(3)

Road trailer with fixed drawbar and ball attachment TR1 0 TR1 0 N/A N/A N/A N/A

Road trailer with hinged drawbar and ring attachment, 68 × 42 mm TR11 TR11 TR11 TR11 N/A N/A

Pintle ring, 40 mm (DIN German) TR21 TR21 TR21 TR21 N/A N/A

Pintle ring, 76 mm TR25 TR25 TR25 TR25 N/A N/A

Ball (universal), 50 mm TR26 TR26 TR26 TR26 N/A N/A

Spare wheel kit TR31 TR31 TR31 TR31 N/A N/A

TR21 Available at no additional cost(1) This option requires special handling and installation(2) Requires different protection(3) Contact your authorized distributor for availability.N/A Not available

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 17

15-03517_IntlSpecA4.indd 17 3/2/16 11:19 am

Page 18: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

GENERATOR SET CONTROLS

Kohler offers a unique range of specific control units: APM303, DEC4000 and APM802. These control units offer a wide

range of possibilities, from simplified running to the option of managing the most complex coupling operations, and can

be adapted to suit every need.

APM303 DEC4000 APM802

KK Series • O X

KM Series • O X

KD Series • O X

KV Series X • O

KH Series X • O

COMPARISON OF THE 3 GENERATOR SET CONTROLS

SPECIFICATIONS APM303 DEC4000 APM802DISPLAY

Frequency • • •Phase to neutral voltages • • •Phase to phase voltages • • •

Currents • • •Active/reactive/apparent power • • •

Power factor • • •Battery voltage • • •Battery current X O OStart-up delay • • •

Fuel level • • •Oil pressure • • •

Coolant temperature • • •Oil temperature X O O

Total working hours counter • • •Partial working hours counter X • •

Total active/reactive energy meter • • •Genset speed • • •

FAULT INFORMATION (FAULT OR ALARM)Min/max alternator voltage • • •

Min/max alternator frequency • • •Min/max battery voltage • • •

Overload and/or short circuit • • •Active/reactive power return X • •

Oil pressure • • •Coolant temperature • • •

Speed too high • • •Speed too low • • •Low fuel level • • •

Emergency stop fault • • •Non-starting fault • • •

Charging alternator fault • • •Differential relay activation fault O • •

General alarm • • •General fault • • •Sound alarm O • •

SPECIFICATIONS APM303 DEC4000 APM802OPERATION

Power ON O • XManual generator set starting • • •

Automatic generator set starting • • •Generator set shut down • • •

Emergency stop • • •Navigation in colour touch-screen menu X X •

Navigation in menu using wheel X • XNavigation in menu using button • X X

Speed adjustment O O •Voltage adjustment O O •

Dual frequency X O ODelayed start programming X • •

Multilingual using pictograms • • XMultilingual text X • •

CONNECTIVITYEthernet port (website) X • •

RS485 (JBUS protocol) • • •Engine CAN Bus (J1939) O • •

USB port (config and software downloading) • • •COUPLING

Under load X O •Shut down X X •

Droop distribution of active and reactive power X O •Parallel line distribution of active and reactive power X X •

CAN Bus distribution of active/reactive power X X •Power plant wattmeter control X X •

Temporary coupling of Out/Return grid X O •Power plant coupling to grid (temporary, permanent, etc.) X X •

GeneralDownloading of a customized

configuration via USB port • • •

• Standard O Option X Not available

• Standard O Option X Not available

18

15-03517_IntlSpecA4.indd 18 3/2/16 11:19 am

Page 19: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

APM303THE ESSENTIALS MADE SIMPLE.

The APM303 is a versatile unit equipped with a particularly intuitive LCD screen. It offers high-quality basic functions,

allowing easy and reliable operation of your generator set. This unit is mounted on a console on all generator sets designed

for LV industrial applications with and without source transfer switch.

FUNCTIONS • Manual and automatic mode (with auto start input)• Generator set protection and management• Electrical measurements, including power• Mechanical value measurements• Automatic voltage and frequency detection• Secure configuration on the APM303 or on PC

CONNECTIVITY• 2 configurable reports• RTU RS485 Modbus

• USB port

OPERATION CONDITIONS• Front of IP54 controller• Protection against humidity and dust with tropicalized varnish

*Advanced Power Management

MEASUREMENTS

LCD DISPLAY EXAMPLES

overview display

output

meters

current and voltage

mechanical values

log and alerts

Ergonomic, universal LCD screen

Alarm/fault report indicator

STOP/START/AUTO buttons and AUTO mode indicator light

Generator set operating light

Screen scroll buttons

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 19

15-03517_IntlSpecA4.indd 19 3/2/16 11:19 am

Page 20: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

DEC4000ERGONOMIC AND INTUITIVE.

ZONE 1: Operation mode (auto/manual/GS output, etc.)

ZONE 2: Display of functions via pictograms

ZONE 3: Display of mechanical and electrical values

and the associated measurements

ZONE 4: Operating messages and parameter settings

menu

ZONE 1

ZONE 4

ZONE 2

SCREEN

Screen with contrast which adjusts to all types of light.

Viewing and remote control functions with option to send an

e-mail, text message or fax in the event of an alarm or a fault

(optional).

FUNCTIONS

Compliance with numerous legal and regulatory requirements

(EC) Integrated diagnostic tool to guide the user when alarms

or faults appear Integrated maintenance monitoring (screen

display of planned maintenance procedures).

CONNECTIVITY

2 USB ports under sealed cover.

OPERATION CONDITIONS

Tropicalization of the electronic board to withstand conditions

of extreme humidity.

Display Screen composed of 4 zones:

Scrolling andvalidation wheel

Menu accessbutton

Generator set stop button

Generator set start button

Escape buttonSystem power ON

Fuse

ON/OFF key switch

Emergency stop button

2 USB ports under a sealed cover

Alarms Faults

Display screen

The KOHLER® DEC4000 Control Unit is straightforward and user-friendly, emphasizing on communication

(USB connections, PC connections, control software and remote operation).

ZONE 3

20

15-03517_IntlSpecA4.indd 20 3/2/16 11:19 am

Page 21: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

The APM802 command/control system is specifically designed for operating and monitoring power plants for markets

including hospitals, data centres, banks, the oil and gas sector, IPP, rental and mining.

The Human Machine Interface (HMI), designed in collaboration with a company specialising in interface design, facilitates

operations with a large 100% touch screen. The pre-configured system for power plant applications features a brand new

customisation function which complies with the international standard IEC 61131-3.

APM802PRECISION AT YOUR FINGERTIPS.

OPERATING SCREEN

Generator set display

Display of installation and mechanical values

Display of generator set electrical values

User access:• shortcuts• maintenance• alarms

Generator set control (operating modes)

Control and position of circuit breakers

Operator and Specialist access:• curves• settings• history• configuration

Display of mains electrical values

Firewall

Remote access via smartphone, tablet or laptop

The ring is created by several Ethernet segments and groups together regulation and PLC communications.

With the ring redundancy option, all

functions remain fully operational

in all circumstances.

Control room

Remote control HMI

ETHERNET COMMUNICATION: INNOVATIVE AND PATENTED

The APM802 Ethernet communication guarantees a high level of equipment availability and facilitates the remote control of

HMI for an enhanced user experience. Additionally, various connections can be made via the Ethernet using fibre optics or

combined with copper wire. System communications are separated from external communications to allow full control of

risk management.

Illustration may vary from actual product.

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 21

15-03517_IntlSpecA4.indd 21 3/2/16 11:19 am

Page 22: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

VERSO

From 35A to 160A, the VERSO is the KOHLER changeover switch. Available in three phase

and single phase versions, it integrates the power detection and allows automatic/manual

start-up of the generator set in the event of a mains power cut.

In industrial applications, the transfer of the main source to the replacement source is crucial

for the running of your installations. Verso is the perfect solution for this requirement: from 35

to 160A, the Verso 100, and from 200A to 3150A, the Verso 200

Verso 100 VERSO S Single phase VERSO S Three phase VERSO D

Ratings (A) 63 100 125 160 35 63 80 100 125 160 35 63 80 100 125 160

Type Single phase Three phase Three phase

Nominal voltage/frequency 230V / 50-60Hz 127 / 230 V / 50-60Hz _ 230 / 400 V / 50-60Hz 127 / 230 V / 50-60Hz _ 230 / 400 V / 50-60Hz

Display and setting Potentiometer Potentiometer Via LCD display

Voltage drop tolerated 20% of the nominal voltage @230V 20% of the nominal voltage @400V 30% of the nominal voltage @400V

Protects against a change in the phase rotation direction X O •

Protection in "0" position X X Rapid automatic protection available for D versions

Lightning arrester X X O

Confirmation of mains return • • •

For France Only • • •

Protection index IP54 IP31 IP54

Dimensions (l x w x h) in, mm 305 x 410 x 150 385 x 385 x 193 400 x 600 x 200

• Standard O Option X Not available

Verso 200

Ratings (A) 200, 250, 315, 400, 630 800, 1000, 1250, 1600 2000, 2500, 3150

Type Three phase

Nominal voltage/frequency 127 / 230 V / 50-60HZ _ 230 / 400 V / 50-60HZ

Configuration Auto-configuration of voltage/frequency min/max and configurable thresholds

Display and setting By LCD - Supplied with manually-operated key - Can be padlocked in manual mode.

Voltage drop tolerated 30% of the nominal voltage @400V

Protects against a change in the phase rotation direction O

Lightning arrester O

EJP pack (for France only) X O O

Confirmation of mains return O

Protection index IP30 (54 on request) IP30 (54 on request) IP54

Inputs/outputs 3 configurable dry contact inputs/2 configurable relay outputs Modbus RTU via isolated RS485 available as an option

Dimensions (l x w x h) in, mm 800 x 600 x 400 1000 x 800 x 500 2000* x 1000 x 800 ≥ 800A

AUTOMATIC TRANSFER SWITCHESFORGET THE FORECAST. WE HAVE YOU COVERED.

22

15-03517_IntlSpecA4.indd 22 3/2/16 11:19 am

Page 23: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

AIPR 1

Standard Option

With manual control on the front panel

3-pole open circuit breaker ✓

4-pole open circuit breaker ✓

Motorized control option*

With 3-pole circuit breaker, open type ✓

Other specifications

Voltage 208V-440V ✓

Power connection bus bars ✓

Protection index IP 23

Dimensions

height × width × depth, mm 1020 × 560 × 238

* The motorized control includes: a closing electromagnet, a shunt trip coil and an AC motor

THE CONTROL CONSOLES

Up to 630A, the power modules are integrated into the consoles. The extra-flexible cables between the console and the

alternator are fitted in a corrugated insulating sleeve.

AIPR

Above 630A, power modules called AIPR are separated from the control/command. These control boxes are fitted on the

generator set chassis and connected to the alternator.

POWER OUTPUT 2 poles 3 poles 4 poles

Modular circuit breaker from 10A to 125A ●(1) X(2) ●

Fixed unit circuit breaker 160A to 630A X ● ❍

(1) Only for single phase generator sets (2) As standard for some neutral connections ● Standard ❍ Option X Not available

POWER MODULES

SPEC YOUR JOB AT KOHLERPOWER.COM.SG 23

15-03517_IntlSpecA4.indd 23 3/2/16 11:19 am

Page 24: International Spec Series - Kohler Power · Reliable, compact, user-friendly and versatile, the International Spec Series generators are built to offer dependable power for all applications

Printed in SingaporeGSF-748 02/16

© 2016 by Kohler Co.

KOHLER® is a registered trademark of Kohler Co. Use of this material for reproduction on the Internet and World Wide Web

is strictly prohibited without written permission from Kohler Co.

SPEC YOUR JOB AT KOHLERPOWER.COM.SG

For more information on the complete range of Kohler products,please contact us at +65 6264 6422or visit KohlerPower.com.sg/Industrial

Southeast Asia Headquarters

Kohler Power Systems - Singapore7 Jurong Pier RoadSingapore 619159 Tel : +65 6264 6422 Fax: +65 6264 6455 Sales inquiries: [email protected]

Regional Sales Offices

S.E. Asia, Taiwan, Hong Kong& Bangladesh

Kohler Power Systems - Singapore 7 Jurong Pier RoadSingapore 619159 Tel: +65 6264 6422 Fax: +65 6264 6455 Email: [email protected]

Australasia

Kohler Power Systems - Australia PO Box 1351, Macquarie Centre Macquarie Park Sydney, NSW 2113Tel: +61 0 428 274 480Email: [email protected]

North Asia

Kohler Power Systems - JapanSBS Hills-II, No. 534-10-3, Yoga, Setagaya-Ku Tokyo 158-0097 Japan Tel: +81 3 6807 1730 Fax: +81 3 3708 4377 Email: [email protected]

Kohler Power Systems - KoreaRoom 1809 LG Twintel 2157-3 Samsung–Dong Gangnam-guSeoul 135-090 South Korea Tel: +82 2 563 9266 Fax: +82 2 563 9730 Email: [email protected]

15-03517_IntlSpecA4.indd 24 3/2/16 11:19 am


Recommended