INTRACATHETERS SHADAB KAMAL 1
Transcript
Page 1: Intracatheters

INTRACATHETERS

SHADAB KAMAL

1

Page 2: Intracatheters

Inroduction2

A plastic tube, usually attached to a puncturing needle, inserted into a blood vessel for infusion, injection, or pressure monitoring.

Page 3: Intracatheters

History3

1929 when a 25 year old surgical resident named Werner Forssman inserted a plastic urethral catheter into the basilic vein in his right arm and then advanced the catheter into the right atrium of his heart.

in 1956 Forssman was awarded the Nobel Prize in Medicine for performing the first right-heart catheterization in a human subject.

Page 4: Intracatheters

Types4

Peripheral vascular catheters

• Venous• Arterial

Central venous catheters

Peripherally inserted central venous catheters

Special catheters

• Hemodialysis Catheters• Introducer Sheaths

• Pulmonary Artery Catheters

Page 5: Intracatheters

Catheter Material5

Made of synthetic polymers (polyurethane and silicone) that are chemically inert, biocompatible, and resistant to chemical and thermal degradation.

Peripheral vascular catheters (arterial and venous), central venous catheters, and pulmonary artery catheters are mostly made of polyurethane, peripherally-inserted central venous catheters (PICCs) are mostly made of silicone.

Page 6: Intracatheters

Catheter Size6

• Gauge size varies inversely with OD (i.e., higher the gauge size, the smaller the OD);

• however, there is no fixed relationship between gauge size and OD.

Gauge Size

Determined by the outside diameter (OD) of the catheter.

• Superior to the gauge system because of its simplicity and uniformity.

• begins at zero, and each increment of one French unit represents an increase of 1/3 (0.33) mm in OD:

• French size × 0.33= OD (mm).

• 3 French units in size will have an OD of 3 × 0.33 = 1.0 mm.

French Size

Page 7: Intracatheters

Various gauze sizes7

Page 8: Intracatheters

Catheter Flow8

Hagen-Poiseuille equation. Steady flow (Q) in a rigid tube is

directly related to the fourth power of the inner radius of the tube (r4), and is inversely related to the length of the tube (L) and the viscosity of the fluid (μ).

Page 9: Intracatheters

PERIPHERAL VASCULAR CATHETERS9

Peripheral blood vessels in adults are cannulated typically 16–20 gauge catheters that are 1–2 inches in length.

inserted using a catheter-over-needle device.

Once flashback is evident, the catheter

is advanced over the needle and into the lumen of the blood vessel.

Page 10: Intracatheters

Catheter-over-needle device for the cannulation of peripheral blood vessels.

10

The catheter fits snugly over the needle and has a tapered end to prevent fraying of the catheter tip during insertion.

The needle has a clear hub to visualize the “flashback” of blood that occurs when the tip of the needle enters the lumen of a blood vessel.

Page 11: Intracatheters
Page 12: Intracatheters

12

Safety needle guard automatically covers the needle's sharp bevel after withdrawal of needle from the hub, minimizing the risk of needle stick injuries.

Page 13: Intracatheters

Sizes and specifications13

Page 14: Intracatheters

14

Page 15: Intracatheters

Indications:15

Fluid and electrolyte replacement Administration of medicines Administration of blood/blood

products Administration of Total Parenteral

Nutrition Haemodynamic monitoring Blood sampling

Page 16: Intracatheters

Advantages:16

Immediate effect Control over the rate of administration Patient cannot tolerate drugs / fluids

orally Some drugs cannot be absorbed by

any other route Pain and irritation is avoided compared

to some substances when given SC/IM

Page 17: Intracatheters

What equipment do you need?17

Dressing Tray Non Sterile Gloves/Apron Cleaning Wipes Gauze swab IV cannula (separate slide) Tourniquet Dressing to secure cannula Alcohol wipes Saline flush and sterile syringe or fluid to be

administered Sharps bin

Page 18: Intracatheters

Preperation: 18

Consult with patient Give explanation Gain consent Position the patient appropriately and

identify the non-dominant hand/arm Support arm on pillow or in other

suitable manner. Check for any contra-indications e.g.

infection, damaged tissue, AV fistula etc.

Page 19: Intracatheters

Encourage venous filling by:19

Correctly applying a tourniquet (applied to the patient’s upper/lower arm at a pressure which is high enough to impede venous distension but not to restrict arterial flow)

Opening & closing the fist

Lowering the limb below the heart

Page 20: Intracatheters

What are the signs of a good vein?20

Bouncy Soft Above previous

sites Refills when

depressed Visible Has a large lumen Well supported Straight Easily palpable

Page 21: Intracatheters

Site of Choice for Veins:

Identify a suitable vein

Page 22: Intracatheters

What veins should you avoid?22

Thrombosed / sclerosed / fibrosed Inflamed / bruised Thin / Fragile Mobile Near bony prominences Areas or sites of infection, oedema or

phlebitis Have undergone multiple previous

punctures Do not use if patient has IV fluid in situ

Page 23: Intracatheters

Small vs. Large Veins23

Catheters placed in small, peripheral veins have a limited life expectancy because they promote localized inflammation and thrombosis.

The inflammation is prompted by mechanical injury to the blood vessel and by chemical injury to the vessel from caustic drug infusions.

The thrombosis is incited by the inflammation, and is propagated by the sluggish flow in small, cannulated veins (low flow in small, cannulated veins is associated with an increase in blood viscosity, and this increases the propensity for thrombus formation).

Page 24: Intracatheters

24

Large veins offer the advantages of a larger diameter and higher flow rates.

The larger diameter allows the insertion of larger bore, multilumen catheters, which increases the efficiency of vascular access (i.e., more infusions per venipuncture).

The higher flow rates reduce the damaging effects of infused fluids and thereby reduce the propensity for local thrombosis.

Page 25: Intracatheters

Procedure 25

Wash hands Prepare equipments Remove the cannula from the

packaging and check all parts are operational

Loosen the white cap and gently replace it

Apply tourniquet Identify vein Clean the site over the vein with

alcohol wipe, allow to dry

Page 26: Intracatheters

26

Remove tourniquet if not able to proceed Put on non-sterile gloves Re-apply the tourniquet, 7-10 cm above site Remove the protective sleeve from the

needle taking care not to touch it at any time

Hold the cannula in your dominant hand, stretch the skin over the vein to anchor the vein with your non-dominant hand (Do not re palpate the vein)

Page 27: Intracatheters

27

Insert the needle (bevel side up) at an angle of 10-30o to the skin (this will depend on vein depth.)

Observe for blood in the flashback chamber

Lower the cannula slightly to ensure it enters the lumen and does not puncture exterior wall of the vessel

Gently advance the cannula over the needle whilst withdrawing the guide, noting secondary flashback along the cannula

Page 28: Intracatheters

28

Release the tourniquet Apply gentle pressure over the vein (beyond

the cannula tip) remove the white cap from the needle

Remove the needle from the cannula and dispose of it into a sharps container

Attach the white lock cap Secure the cannula with an appropriate

dressing Flush the cannula with 2-5 mls 0.9% Sodium

Chloride or attach an IV giving set and fluid

Page 29: Intracatheters

Finally:29

Document the procedure including Date & time Site and size of cannula Any problems encountered Review date (cannula should be in situ no

longer than 72 hours without appropriate risk assessment.)

Note: some hospitals have pre-printed forms to record cannula events

Thank the patient Clean up, dispose of rubbish

Page 30: Intracatheters

Possible Complications: 30

direct access to a patient's vascular system so provides a potential route for entry of micro organisms into that system.

cause serious infection if they are allowed to enter and proliferate in the IV cannula, insertion site, or IV fluid.

Page 31: Intracatheters

IV-Site Infection:31

Does not produce much (if any) pus or inflammation at the IV site.  This is the most common cannula-related infection.

Page 32: Intracatheters

Cellulites: 32

Warm, red and often tender skin surrounding the site of cannula insertion; pus is rarely detectable.

Page 33: Intracatheters

Infiltration or tissuing 33

occurs when the infusion (fluid) leaks into the surrounding tissue. It is important to detect early as tissue necrosis could occur – re-site cannula immediately

Page 34: Intracatheters

Thrombolism / thrombophlebitis

34

occur when a small clot becomes detached from the sheath of the cannula or the vessel wall – prevention is the greatest form of defence.

Flush cannula regularly and consider re-siting the cannula if in prolonged use.

Page 35: Intracatheters

Extravasation35

accidental administration of IV drugs into the surrounding tissue, because the needle has punctured the vein and the infusion goes directly into the arm tissue.

The leakage of high osmolarity solutions or chemotherapy agents can result in significant tissue destruction, and significant complications

Page 36: Intracatheters

Bruising36

commonly results from failed IV placement - particularly in the elderly and those on anticoagulant therapy.

Page 37: Intracatheters

Air embolism37

occurs when air enters the infusion line, although this is very rare it is best if we consider the preventive measures – Make sure all lines are well primed prior to use and connections are secure

Page 38: Intracatheters

Haematoma38

occurs when blood leaks out of the infusion site. The common cause of this is using cannula that are not tapered at the distal end. It will also occur if on insertion the cannula has penetrated through the other side of the vessel wall – apply pressure to the site for approximately 4 minutes and elevate the limb

Page 39: Intracatheters

Phlebitis39

It is common in IV therapy and can be caused in many ways.

It is inflammation of a vein (redness and pain at the infusion site)

prevention can be using aseptic insertion techniques, choosing the smallest gauge cannula possible for the prescribed treatment, secure the cannula properly to prevent movement and carry out regular checks of the infusion site.

Page 40: Intracatheters

Arterial catheter40

a thin catheter inserted into an artery. to monitor the BP real-time (rather than

by intermittent measurement), and to obtain samples for ABG measurements.

not used to administer medication inserted in the wrist (radial artery); but

can also be inserted into the elbow (brachial artery), groin (femoral artery), foot (dorsalis pedis artery) or the inside of the wrist (ulnar artery).

Page 41: Intracatheters

Central Venous Catheters41

Used for cannulation of larger, more centrally placed veins (i.e., subclavian, internal jugular, and femoral veins) is often necessary for reliable vascular access in critically ill patients.

They are typically 15 to 30 cm (6 to 12 inches) in length, and have single or multiple (2–4) infusion channels.

Multilumen catheters are favored in the critically ill patient recquires a multitude of parenteral therapies (e.g., fluids, drugs, and nutrient mixtures).

Multilumen catheters make it possible to deliver these therapies using a single venipuncture.

Page 42: Intracatheters

42

Triple-lumen catheters are favorite for central venous access.

These catheters are available in sizes of 4-9 French.

Size 7 French(OD=23mm) triple lumen catheter is a popular choice in adults, which typically have one 16 gauge channel and two smaller 18 gauge channels.

To prevent mixing of infusate solutions, the three outflow ports are separated.

Page 43: Intracatheters

43

Page 44: Intracatheters

44

Page 45: Intracatheters

Indications45

When peripheral venous access is difficult to obtain (e.g., in obese or intravenous drug abusers) or difficult to maintain (e.g., in agitated patients).

For the delivery of vasoconstrictor drugs (e.g., dopamine, norepinephrine), hypertonic solutions (e.g., parenteral nutrition formulas), or multiple parenteral medications.

For prolonged parenteral drug therapy (i.e., more than a few days).

For specialized tasks such as hemodialysis, transvenous cardiac pacing, or hemodynamic monitoring (e.g., with pulmonary artery catheters).

Page 46: Intracatheters

Contraindications:46

There are no absolute contraindications except inexperienced operator is in this procedure, including the presence or severity of a coagulation disorder.

Relative contraindicatios Inexperience operator with unsupervised

operator, Local infection, Distorted local anatomy, Coagulopathy, Previous radiation therapy, Suspected proximal vascular injury

Page 47: Intracatheters

Insertion Technique47

Central venous catheters are inserted by threading the catheter over a guidewire (Seldinger technique).

A small bore needle (usually 20 gauge) is used to probe for the target vessel. When the tip of the needle enters the vessel, a long, thin wire with a flexible tip is passed through the needle and into the vessel lumen.

The needle is then removed, and a catheter is advanced over the guidewire and into the blood vessel.

Page 48: Intracatheters

Seldinger technique48

When cannulating deep vessels, a larger and more rigid “dilator catheter” is first threaded over the

guide-wire to create a tract that facilitates insertion of the vascular catheter.

Page 49: Intracatheters

Central Line Bundle49

Page 50: Intracatheters

Peripherally Inserted Central Catheters

50

peripherally inserted central catheters (PICCs), which are inserted in the basilic or cephalic vein in the arm (just above the antecubital fossa) and advanced into the superior vena cava.

Useful in patients with concern for the adverse consequences of central venous cannulation (e.g., pneumothorax arterial puncture, poor patient acceptance)

PICCs are used primarily when traditional central venous accesss are considered risky (e.g., severe thrombocytopenia) or are difficult to obtain (e.g., morbid obesity).

Page 51: Intracatheters

51

Page 52: Intracatheters

PICC vs CVC52

Major distinction between PICCs and central venous catheters is their length; i.e., the length of the catheters(50 cm and 70 cm) is at least double the length of the triple lumen catheters.

Because of this added length there is reduction in flow capacity in PICC.

Flow is particularly sluggish in the double lumen PICCs because of the smaller diameter of the infusion channels.

The flow limitation of PICCs (especially the double lumen catheters) makes them ill-suited for aggressive volume therapy.

Page 53: Intracatheters

Hemodialysis Catheters53

One of the recognized benefits of intensive care units is the ability to provide emergent hemodialysis for patients with acute renal failure,

Hemodialysis catheters are the wide-body catheters of critical care, with diameters up to 16 French (5.3 mm), and they are equipped with dual 12 gauge infusion channels that can accommodate the high flow rates (200–300 mL/min) needed for effective hemodialysis.

One channel carries blood from the patient to the dialysis membranes, and the other channel returns the blood to the patient.

Page 54: Intracatheters

54

Page 55: Intracatheters

55

Page 56: Intracatheters

Introducer Sheaths56

Introducer sheaths are large-bore (8–9 French) catheters that serve as conduits for the insertion and removal of temporary vascular devices.

They are used primarily to facilitate the placement of pulmonary artery (PA) catheters

The introducer sheath is first placed in a large, central vein, and the PA catheter is then threaded through the sheath and advanced into the pulmonary artery.

Page 57: Intracatheters

57

The placement of PA catheters often requires repeated trials of advancing and retracting the catheter to achieve the proper position in the pulmonary artery, and the introducer sheath facilitates these movements.

When the PA catheter is no longer needed, the introducer sheath allows the catheter to be removed and replaced with a central venous catheter, if needed, without a new venipuncture.

serve as stand-alone infusion devices-with pressurized infusion systems, flow rates of 850 mL/min have been reported

Page 58: Intracatheters

Pulmonary Artery Catheters58

Pulmonary artery balloon-flotation catheters are highly specialized devices capable of providing various measures of cardiovascular function and systemic oxygenation.

Page 59: Intracatheters

59

Cannulation- How to gain IV access.mp4