+ All Categories
Home > Documents > Introducing ANGIOVUE ESSENTIAL - Haag-Streit Diagnostics...Pachymetry map image courtesy of Barry...

Introducing ANGIOVUE ESSENTIAL - Haag-Streit Diagnostics...Pachymetry map image courtesy of Barry...

Date post: 24-Oct-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
6
Introducing ANGIOVUE ESSENTIAL OCT Angiography for Primary Eye Care Built on the Avanti Widefield OCT Platform
Transcript
  • Introducing

    ANGIOVUE ESSENTIAL

    OCT Angiography for Primary Eye Care

    Built on the Avanti Widefield OCT Platform

  • Transform Your View of the RetinaOCT Angiography (OCTA) is a quick non-invasive test that lets you see retinal vessels without referring patients out of the practice.

    Ease into OCT Angiography AngioVue Essential makes OCTA easy to use and interpret with a single-page report displaying individual layers of retinal vasculature alongside structural OCT B-scans.

    Gain peace of mind in high risk cases, expand your ability to manage patients with ocular disease and make better-informed referral and management decisions.

    Diabetic RetinopathyImages courtesy of Dan Esmaili, MD

  • Observe Early Vascular Changes in Diabetic Eyes

    Visualize Neovascularization Associated with Pigment Epithelial Detachments

    Confirm Presence or Absence of CNV in AMD

    Capillary Dropout & FAZ Remodeling

    Capillary Dropout & FAZ Remodeling in Diabetic Eye

    Abnormal Vasculature in Outer Retina and Choriocapillaris

    CNV in Outer Retina and Choriocapillaris

    Normal Eye

    Diabetic and AMD images courtesy of Kent Small, MD. PED images courtesy of Julie Rodman, OD, FAAO.

  • Advanced Structural ImagingRetinaWidefield and Enhanced HD Line Scans and the Widefield En Face Quad Image provide stunning views of the retina, vitreous and choroid to give you deeper insights into retinal and choroidal diseases.

    12mm Widefield ScanImage courtesy of Adil El Maftouhi, OD

    Enhanced HD Line Scan Image courtesy of Adil El Maftouhi, OD

    9x12mm Widefield En Face Quad-Image

  • Estimate Rate of Change in GCC and RNFL Thickness

    Advanced Structural Imaging (continued)

    Cornea Line Scan with Measurement ToolsImage courtesy of Jeff Sonsino, OD, FAAO

    Anterior SegmentVisualize and quantify anterior segment structures to aid in disease diagnosis, assess patients considering refractive surgery, and manage post-surgical patients.

    GlaucomaChange the way you see your glaucoma patients with Avanti’s trend analysis software that tracks change in GCC and RNFL thickness while also providing the GCC focal loss volume (FLV) metric that is the single best predictor of conversion to glaucoma1.

    Pachymetry Map : KeratoconusImage courtesy of Barry Eiden, OD, FAAO

    Angle Scan with Measurement Tools

    Wellness Solutions Optovue’s industry-leading wellness solution is now available on the AngioVue Essential system.

    • Aids in diagnosis of ocular disease

    • Differentiates your practice and motivates patients to return for annual exam

    • Creates a new revenue stream

    1. Zhang X, Loewen N, Tan O, Greenfield D, Schuman J, Varma R, Huang D. Predicting Development of Glaucomatous Visual Field Conversion Using Baseline Fourier-Domain Optical Coherence Tomography. Am J Ophthalmol. 2016 Mar; 163:29-37.

    Cornea line scan image courtesy of Jeff Sonsino, OD, FAAO. Pachymetry map image courtesy of Barry Eiden, OD, FAAO.

  • PH: +1 510.623.8868 | FX: +1 510.623.8668 PN 300-52860 Rev. A

    Specifications

    Technical Specifications

    OCT scanning speed 70,000 A-scans per second

    Optical axial resolution ~5 microns (digital pixel sampling = 3 μm)

    Optical transverse resolution ~15 microns

    OCT axial imaging depth 2 to 3 mm (dependent on scan protocol)

    AngioVueHD imaging volume 6x6 mm 400 x 400 A-lines (2 repeats / B-scan)

    Acquisition time per imaging volume (209K / 70K) ~3 seconds

    Recommended Networking Specifications

    Operating System Windows 7, 8 and 10; 64-bit OS compatible

    Processor Speed 3.0 GHz; Intel Quad core (desktop); Core 2 (laptop)

    Network Bandwidth 1 Gbps or higher

    Computer RAM 4 GB or higher

    Monitor Resolution 1920 x 1080 at 32-bit color

    Built on the Avanti Widefield OCT Platform • High-speed scanning and accelerated data processing increase efficiency

    • DualTrac™ Motion Correction Technology improves image quality and makes scan acquisition easier

    • Optovue’s data transfer solutions let you maintain existing patient data


Recommended