7
introducing PATHWAY LIGHTING’S LED LUMINAIRES the LED lighting source Magner Sanborn Office, Spokane, Washington Architect: Uptic Studios Photography: Shaun Cammack
Transcript
Page 1: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

i n t r o d u c i n g

PATHWAYLIGHTING’S LED LUMINAIRES

t h e LED l i g h t i n g s o u r c e

Magner Sanborn Office, Spokane, WashingtonArchitect: Uptic StudiosPhotography: Shaun Cammack

Page 2: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

p a t h w a y l i g h t i n g . c o mpage two

PATHWAY LIGHTING’S LED LUMINAIRES

S y n J e t

H e a t S i n k

F o r t i m o L E D D o w n l i g h t M o d u l e

X i t a n i u m D r i v e r

R e f l e c t o r / T r i m

1st in Class & Best in Class | As the first lighting manufacturer to integrate Philips’ Fortimo LED Downlight Module, Pathway has always been at the forefront of luminaire development, solving design and technical challenges associated with LED lighting application—thermal management, lamp life, color consistency, scalability, maintenance, and glare. Pathway is committed to eliminating design barriers and in working closely with lighting specifiers, to create functional, comfortable, memorable visual environments.

Thermal Management | in conjunction with a compact aluminum heat sink, all Fortimo LED Downlight Modules rated at 2000 initial lumens and higher are cooled by Nuventix’s SynJet active cooling module. The SynJet module—a low-power, effectively silent, advanced cooling technology—creates turbulent, pulsated air jets, which can be directed between the fins of the heat sink, resulting in high heat transfer coefficient air flows that provide optimum thermal operating environment for the Fortimo LED Downlight Module.

Color Consistency | remote phosphor technology, a color mixing chamber and tight LED binning work in concert to ensure color consistency from fixture to fixture, with no visible LEDs, and virtually no color shift over the life of the engine.

Scalability & Maintenance | all Pathway LED luminaires are engineered to accommodate future improvements in LED technology. As Philip’s Fortimo LED Downlight Modules continue to improve in performance, updating installed luminaires in the field will be as easy as replacing the Fortimo Module and/or its intelligent Xitanium driver—maintenance that is simple, familiar, and in all cases can be done from below the ceiling.

Include a complete line of recessed-, surface-, and pendant-mounted LED lighting solutions, engineered to provide lighting specifiers with reliable, high-performance, sustainable LED products.

DPR Construction Headquarters, Glenn Allen, VirginiaArchitect: Evolve ArchitecturePhotography: David Galen

T h e r m a l T r a n s f e r P a d

Page 3: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

page four p a t h w a y l i g h t i n g . c o m

LED AS CFL DOWNLIGHT REPLACEMENT

… i t ’ s a b o u t t i m e

Light Output | when comparing CFL and LED downlights, it is important that the analysis is a true apples-to-apples comparison—one where lumen rating is discussed in terms of delivered lumens, not in terms of initial lumens, for both systems. Pathway Lighting’s design team uses today’s most advanced LED engines to deliver lumen output that exceeds the performance and equivalent efficacy of even the most efficient CFL downlight (approx. efficiency 70% or 45-50 lm/w) on the market today.

Life | superior thermal management leads to LED products that are rated at 50,000 hours to 70% light output (L70), which is four times the life of a typical CFL equivalent. Longer life means lower cost of ownership.

Dimmability | an intelligent LED driver that provides 0-10V dimming to 10% comes standard at no extra charge, making our LED systems cost competitive with CFL-based lighting fixtures running on expensive electronic dimming ballasts. Our products are compatible with major dimming control systems and protocols. Please contact factory for assistance and further information.

Sustainability | unlike CFL-based products, LEDs are mercury-free and consume less energy, creating a smaller ecological footprint.

Peace of Mind | all of our LED products are backed by an industry standard, 5-Year limited warranty.

Magner Sanborn Office, Spokane, WashingtonArchitect: Uptic Studios

Photography: Shaun Cammack

Solerio LED Pendant

P a t h w a y 6 V L E D 110 0 l m 3 2 W C F L 3 2 W C F L

lamp life 50,000 20,000 12,000

W/fixture 17 37 37

$/kWh $0.12 $0.12 $0.12

# hours/year @ 12 hr/Business Day

3132 3132 3132

kWh per year 53.24 115.88 115.88

energy cost per year $6.39 $13.91 $13.91

estimated lamp cost 80 15 15

driver or ballast cost 50 50 50

estimated labor cost 75 75 75

total cost of ownership – 5 years

$31.95 $69.53 $159.53

total cost of ownership – 10 years

$63.89 $229.06 $319.06

total cost of ownership – 15 years

$95.84 $513.59 $693.59

total cost of ownership – 20 years

$407.79 $673.12 $853.12

ope r a t i ng c o s t c ompa r i s on f o r e q u i va l en t C F L & L ED down l i gh t s

p r o d u c t a v e r a g e l i g h t l e v e l ( F C )

u n i f o r m i t y( m a x / m i n ) w / s q . f t .

Pathway 6VLED 1100 lm 17W

13.1 1.83:1 0.35

Pathway 6” 32W CFL Downlight

13.3 1.87:1 0.77

Brand A- 6” 32W CFL Downlight

13.0 1.91:1 0.73

Brand B- 6” 32W CFL Downlight

14.9 2.06:1 0.67

Brand C- 6” 32W CFL Downlight

11.6 2.01:1 0.75

c o r r i do r c a l c u l a t i on s

40’0”

8’0” o

.c. ty

p.

6’0”

p r o d u c t a v e r a g e l i g h t l e v e l ( F C )

u n i f o r m i t y( m a x / m i n ) w / s q . f t .

6” Round 34W LED Downlight 2000 lm (6VLED2000 Medium)

39.3 2.53:1 0.95

6” Round 42W CFL Downlight (6HF1 Open)

31.6 2.32:1 1.33

6” Round 42W CFL Downlight (6HF1 Lensed)

22.8 2.15:1 1.33

12’0”

6’0” o

.c. ty

p.

12’0”

sma l l c o n f e r en c e r oom c a l c u l a t i on

Cost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced once during the 20-year period. CFL on 12 hour/start has a rated lamp life to 20,000 hours; lamp replaced in years 6, 12, 19. CFL on shorter on/off cycle has a rated life of 12,000 hours; lamp replaced in years 3, 7, 11, 15, 19. Ballast replaced once. All component and labor costs are based on market levels at the time of printing.

Ceiling height = 9’-0”. Room surface reflectances = 80/50/20. LLF = 0.85. Illuminance measurements taken at floor.

Ceiling height = 9’-0”. Room surface reflectances = 80/50/20. LLF = 0.85. Illuminance measurements taken at 30” AFF.

small conference room corridor

Page 4: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

p a t h w a y l i g h t i n g . c o m p a t h w a y l i g h t i n g . c o m

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” SQUARERECESSED

DOWNLIGHT

4SQLED 1100 initial 4,000 k

914 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” SQUARERECESSED

WALLWASH

4SQLEDWW 1100 initial 4,000 k

523 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” ROUNDRECESSED

WALLWASH

6VLEDWW 1100 initial 4,000 k

960 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” ROUNDRECESSED

WALLWASH

4VLEDWW 1100 initial 4,000 k

903 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” SQUARERECESSED

WALLWASH

6SQLEDWW 1100 initial 4,000 k

679 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” SQUARERECESSED

DOWNLIGHT

6SQLED 1100 initial 4,000 k

1035 delivered 3,500 k

3,000 k

4 ” S Q U A R E A P E R T U R E , 110 0 L U M E N

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

505

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

442

378

315

252

189

126

63

0

4” square 1100 downlight

2015105 20 5 30

35

40

45

50

55

60

65

70

75

80

85

90

320

240

160

80

0

4” square 1100 wall wash

8.0' 13.7 14.8’

10.0' 7.4 18.5’

12.0' 4.6 22.2’

14.0' 3.1 25.9’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

6 ” S Q U A R E A P E R T U R E , 110 0 L U M E N

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 27.4 10.2’

10.0' 14.7 12.7’

12.0' 9.2 15.3’

14.0' 6.3 17.8’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

page six page seven

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 33 9.8’

10.0' 17.8 12.3’

12.0' 11.1 14.7’

14.0' 7.6 17.2’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” ROUNDRECESSED

DOWNLIGHT

4VLED 1100 initial 4,000 k

941 delivered 3,500 k

3,000 k

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 58.2 6.0’

10.0' 31.3 7.5’

12.0' 19.5 9.0’

14.0' 13.3 10.5’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” ROUNDRECESSED

DOWNLIGHT

6VLED 1100 initial 4,000 k

971 delivered 3,500 k

3,000 k

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

4 ” R O U N D A P E R T U R E , 110 0 L U M E N

6 ” R O U N D A P E R T U R E , 110 0 L U M E N

1.091.09

754

20151050

25

30

35

40

45

50

55

60657075808590

660

566

472

377

283

189

94

6” square 1100 downlight 6” square 1100 wall wash

40045

50

55

65

70

80

85

40

60

75

90

300

200

100

0

20151050 25 30 35

1.051.05

20151050 25

30

35

40

45

50

55

60657075808590

888

777

666

555

444

333

111

222

4” round 1100 downlight 4” round1100 wall wash

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

973

730

487

243

0

.67.67

1565

1761

1369

1174

978

782

587

391

196

0

20

151050

25

30

35

4045505560657075808590

6” round 1100 downlight

312

469

625

781

937

1093

1250

156

0

20151050

45

50

55

65

70

80

85

40

35

30

25

60

75

90

6” round 1100 wall wash

54.754.7 27.5

27.5

62.062.037.137.1

56.356.3 54.1

54.1

58.258.257.557.5

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 5 4

2’ 8 8

3’ 7 8

4’ 7 8

5’ 6 7

6’ 4 5

7’ 3 3

8’ 2 3

9’ 2 2

10’ 1 1

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 5 4

2’ 10 7

3’ 9 11

4’ 9 10

5’ 7 8

6’ 5 6

7’ 4 4

8’ 3 3

9’ 2 2

10’ 2 2

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 6 6

2’ 8 9

3’ 7 8

4’ 6 6

5’ 6 7

6’ 5 7

7’ 5 6

8’ 4 5

9’ 3 4

10’ 3 3

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 4 4

2’ 9 10

3’ 8 8

4’ 9 10

5’ 8 9

6’ 7 7

7’ 5 6

8’ 5 5

9’ 4 4

10’ 3 3

0=1.110=1.11

90=1.0490=1.04

0=1.200=1.20

90=1.1190=1.11

0=0.830=0.83

90=1.0590=1.05

0=0.660=0.66

90=0.6990=0.69

vertical FC on wall vertical FC on wall

vertical FC on wall vertical FC on wall

Page 5: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

p a t h w a y l i g h t i n g . c o m p a t h w a y l i g h t i n g . c o m page nine

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” ROUNDRECESSED

WALLWASH

6VLEDWW 2000 initial 4,000 k

1748 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” ROUNDRECESSED

WALLWASH

4VLEDWW 2000 initial 4,000 k

1497 delivered 3,500 k

3,000 k

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 60.6 9.6’

10.0' 32.6 12.0’

12.0' 20.3 14.4’

14.0' 13.9 16.8’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” ROUNDRECESSED

DOWNLIGHT

4VLED 2000 initial 4,000 k

1704 delivered 3,500 k

3,000 k

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 104.8 6.0’

10.0' 56.4 7.5’

12.0' 35.1 9.0’

14.0' 24.0 10.5’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” ROUNDRECESSED

DOWNLIGHT

6VLED 2000 initial 4,000 k

1766 delivered 3,500 k

3,000 k

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

4 ” R O U N D A P E R T U R E , 2 0 0 0 L U M E N

6 ” R O U N D A P E R T U R E , 2 0 0 0 L U M E N

1.041.04

.68.68

20151050 25

35

40

30

45

50

55

60657075808590

1629

1426

1222

1018

815

611

204

407

4” round 2000 downlight 4” round 2000 wall wash

40

60

75

90

1200

1500

900

600

300

20151050 25 30 35

45

50

55

65

70

80

85

2819

3171

2466

2114

1762

1409

1057

705

352

0

20

151050

25

30

35

4045505560657075808590

6” square 2000 downlight

640

480

320

160

0

20151050 25 30 35

45

50

55

65

70

80

85

40

60

75

90

6” square 2000 wall wash

49.749.7 41.5

41.5

51.551.548.048.0

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 10 9

2’ 14 15

3’ 11 13

4’ 10 10

5’ 9 11

6’ 9 10

7’ 8 9

8’ 7 7

9’ 6 6

10’ 4 5

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 7 7

2’ 16 17

3’ 14 15

4’ 16 17

5’ 14 17

6’ 12 13

7’ 10 11

8’ 8 9

9’ 7 7

10’ 6 6

0=0.810=0.81

90=1.0590=1.05

0=0.660=0.66

90=0.7090=0.70

vertical FC on wall

vertical FC on wall

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” SQUARERECESSED

WALLWASH

4SQLEDWW 2000 initial 4,000 k

955 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

4” SQUARERECESSED

DOWNLIGHT

4SQLED 2000 initial 4,000 k

1662 delivered 3,500 k

3,000 k

page eight

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” SQUARERECESSED

WALLWASH

6SQLEDWW 2000 initial 4,000 k

1129 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” SQUARERECESSED

DOWNLIGHT

6SQLED 2000 initial 4,000 k

1547 delivered 3,500 k

3,000 k

4 ” S Q U A R E A P E R T U R E , 2 0 0 0 L U M E N

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 24.2 14.8’

10.0' 13.0 18.5’

12.0' 8.1 22.2’

14.0' 5.5 25.9’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

6 ” S Q U A R E A P E R T U R E , 2 0 0 0 L U M E N

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 49.8 10.2’

10.0' 26.8 12.7’

12.0' 16.7 15.3’

14.0' 11.4 17.8’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

c a n d e l ad i s t r i b u t i o n p e r f o r m a n c e d a t a s p a c i n g

c r i t e r i a

1.091.09

918

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

803

688

574

459

344

229

115

0

4” square 2000 downlight

600

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

450

300

150

0

4” square 2000 wallwash

1372

20151050

25

30

35

40

45

50

55

60657075808590

1200

1029

857

686

514

343

171

6” square 2000 downlight

640

480

320

160

0

20151050 25 30 35

45

50

55

65

70

80

85

40

60

75

90

6” square 2000 wall wash

48.548.5 26.2

26.2

43.943.932.232.2

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 8 7

2’ 14 13

3’ 14 14

4’ 13 15

5’ 11 13

6’ 8 9

7’ 6 6

8’ 4 5

9’ 3 4

10’ 3 3

DISTANCE FROM

CEILING

3’ O.C.; 3’ Set Back

Below Fixtures

Between Fixtures

1’ 7 6

2’ 11 11

3’ 14 15

4’ 14 17

5’ 12 13

6’ 9 10

7’ 7 7

8’ 5 5

9’ 4 4

10’ 3 3

0=1.170=1.17

90=1.0290=1.02

0=1.140=1.14

90=1.1490=1.14

vertical FC on wall

vertical FC on wall

Page 6: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

p a t h w a y l i g h t i n g . c o m

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

PENDANT WITH

ACRYLIC REFRACTOR

SHADE

P2MLD2 2000 initial 4,000 k

1613 delivered 3,500 k

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

8” APERTURECYLINDER

surface:C2SLED

2000 initial 4,000 k

pendant:C2PLED

1774 delivered 3,500 k

wall:C2WLED

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

6” APERTURECYLINDER

surface: C65SLED

1100 initial 4,000 k

pendant:C65PLED

971 delivered 3,500 k

wall:C65WLED

3,000 k

d e s c r i p t i o n s e r i e s l u m e n p a c k a g e ( l m )

c o l o r t e m p e r a t u r e e f f i c a c y ( l p w )

8” APERTURECYLINDER

surface:C3SLED

2000 initial 4,000 k

pendant:C3PLED

1774 delivered 3,500 k

wall:C3WLED

3,000 k

page ten page eleven

S E R I E S C 6 5

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i ac a n d e l a

d i s t r i b u t i o n c o n e o f l i g h t s p a c i n g c r i t e r i a

S E R I E S C 2 S

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 79.1 4.9’

10.0' 41.3 6.8’

12.0' 25.3 8.6’

14.0' 17.1 10.5’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

c a n d e l ad i s t r i b u t i o n c o n e o f l i g h t s p a c i n g

c r i t e r i a

8.0' 58.9 4.1’

10.0' 30.9 5.6’

12.0' 19.0 7.2’

14.0' 12.8 8.9’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

S O L E R I O P E N D A N T

8.0' 79.1 4.9’

10.0' 41.3 6.8’

12.0' 25.3 8.6’

14.0' 17.1 10.5’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

942

1177

1413

1648

1884

2119

235

471

706

0

C2 & C3

1200

1500

900

600

300

0

20151050 25 30 35

40

45

50

55

60

65

70

75

80

85

90

Solerio Pendant

42.242.4

.76.76

S E R I E S C 3 S

8.0' 58.2 6.0’

10.0' 31.3 7.5’

12.0' 19.5 9.0’

14.0' 13.3 10.5’

CEILING HEIGHT FC (NADIR) BEAM DIA.

Initial Footcandles at a 30" Work Plane; Beam diameter calculated at 50% of maximum fc at nadir.

58.258.2

.67.67

48.748.7

.93.93

48.748.7

.93.93

1565

1761

1369

1174

978

782

587

391

196

0

20

151050

25

30

35

4045505560657075808590

C65

k e y w o r ds e a r c h s e r i e s l u m e n s c o l o r

t e m p e r a t u r ei n p u t

v o l t a g e m o u n t i n g o p t i o n s o p t i o n a l f i n i s h e s f o r c y l i n d r i c a l h o u s i n g o p t i o n s / a c c e s s o r i e s

P2MLD2 P2M = pendant with acrylic

refractor shade

LD2 = 2000 lumens

4K (4000K)

35K (3500K)

3K (3000K)

blank = 120/277

volt standard

C = adjustable aviation cable & 10’

coiled cord

S = adjustable aviation cable & 10’ straight

cord

P = pendant, for use with separate

pendant kit

PH = power hook

F = fuse blank = satin anodized aluminum

W = matte white

B = matte black

Z = bronze

SA = satin aluminum

MA = glossy metallic aluminum

mounting kits for pendant hung cylinders:

PK24 = 24” pendant kit

PK36 = 36” pendant kit

PK48 = 48” pendant kit

PK60 = 60” pendant kit

k e y w o r d s e a r c h s e r i e s l u m e n s c o l o r

t e m p e r a t u r ei n p u t

v o l t a g e o p t i o n s / a c c e s s o r i e s r e f l e c t o r f i n i s h t r i m f l a n g e f i n i s h

d e c o r a t i v e a c c e s s o r i e s

4SQLED 4SQLED = 4” square aperture

downlight

1100

2000

4K (4000K)

35K (3500K)

3K (3000K)

blank = 120/277

volt standard

EM = emergency operation

hanger bars:

9127 = 27” c-channel

9152 = 52” c-channel

27BH = 27” solid bar

101782 = caddy #520

4SQLED = 4” square reflector

SCL = soft specular clear alzak

SWT = soft specular wheat

SST = soft specular straw

SPW = soft specular pewter

SBZ = soft specular bronze

SBL = soft specular black

see additional reflector finishes on next page.

PF = polished self flange

blank = matte white flange

IC4 = suspended 4” square ICE lens

4SQLEDWW 4SQLEDWW = 4” square aperture

wall wash

4SQLEDWW = 4” square wall wash reflector

6SQLED 6SQLED = 6” square aperture

downlight

6SQLED = 6” square reflector

IC6 = suspended 6” square ICE lens

6SQLEDWW 6SQLEDWW = 6” square aperture

wall wash

6SQLEDWW = 6” square wall wash reflector

4VLED 4VLED = 4” round aperture downlight

4VLED = 4” round downlight reflector

IC4 = suspended 4” round ICE lens

4VLEDWW 4VLEDWW = 4” round aperture

wall wash

4VLEDWW = 4” round wall wash reflector

6VLED 6VLED* = 6” round aperture downlight

6VLED = 6” round downlight reflector

IC6 = suspended 6” round ICE lens

6VLEDWW 6VLEDWW = 6” round aperture

wall wash

6VLEDWW = 6” round wall wash reflector

k e y w o r d s e a r c h s e r i e s m o u n t i n g o p e r a t i o n l u m e n s c o l o r

t e m p e r a t u r ei n p u t

v o l t a g e o p t i o n s / a c c e s s o r i e s o p t i o n a l c y l i n d e r f i n i s h e s r e f l e c t o r f i n i s h t r i m f l a n g e

f i n i s h

C65SLED C65* = 6” aperture cylinder,

8” diam. X 12.6” tall

S = surface mount

P = pendant,

for use with separate

pendant kit

W = wall mount

LED = led operation

1100

2000

4K (4000K)

35K (3500K)

3K (3000K)

blank = 120/277

volt standard

F = fuse

mounting kits for pendant hung cylinders:

PK24 = 24” pendant

PK36 = 36” pendant

PK48 = 48” pendant

PK60 = 60” pendant

blank = matte white

B = matte black

Z = bronze

SA = satin aluminum

MA = glossy metallic aluminum

GAL = textured galvanite

6VLED = 6” apert. downlight reflector

SCL = soft specular

clear alzak

SWT = soft specular wheat

SST = soft specular straw

SPW = soft specular pewter

SBZ = soft specular bronze

HAZ = matte haze

see additional reflector finishes

on next page.

PF = standard with polished

self flange

C2SLED C2 = 8” aperture cylinder, 10”

diam. X 12.5” tall

8VLED = 8” apert. downlight reflector

C3SLED C3 = 8” aperture cylinder, 10”

diam. X 16” tall

*C65 cylinder available in

1100 lumens only.

R e c e s s e d D o w n l i g h t s E x a m p l e : 4 S Q L E D 110 0 4 K E M / 9 12 7 / 4 S Q L E D S C L P F - I C 4to access specification sheets online, enter keyword search at www.pathwaylighting.com, example 4SQLED.

C y l i n d e r s E x a m p l e : C 6 5 S L E D 110 0 4 K - B / 6 V L E D S C L P Fto access specification sheets online, enter keyword search at www.pathwaylighting.com, example C65SLED.

P e n d a n t E x a m p l e : P 2 M L D 2 4 K E 1 Cto access specification sheets online, enter keyword search at www.pathwaylighting.com, example P2MLD2.

How to Specify Pathway Lighting’s LED Luminaires

*6VLED available in two beam distributions, 42° spot (SP) and 58° medium (MD).

20151050 25 30

35

40

45

50

55

60

65

70

75

8085

90

942

1177

1413

1648

1884

2119

235

471

706

0

C2 & C3

Page 7: introducing PATHWAY LIGHTING’S LED LUMINAIRESCost comparison above assumes labor cost is incurred for each lamp, ballast or driver replacement. LED module and driver are replaced

p a t h w a y l i g h t i n g . c o m

SBLPFSoft Specular Black

MWHMatte White Finish

HAZPFHaze

EWTPFDiffused Wheat

ESTPFDiffused Straw

EPWPFDiffused Pewter

SWTPFSoft Specular Wheat

SSTPFSoft Specular Straw

SPWPFSoft Specular Pewter

CRGCorrugated Clear Alzak

SCLPFSoft Specular Clear

SBZPFSoft Specular Bronze

EBZPFDiffused Bronze

REFLECTOR f i n i s h e s

c o n t a c t u sPathway Lighting Products, Inc.P.O. Box 591, Old Saybrook, CT 06475-0591voice: 800.342.0592 or 860.388.6881fax: 800.207.0090 or 860.388.5766email: [email protected]

GLASS o p t i o n s

ESSEX DECO LUNA PARK AVENUE MIRIAM CYLINDER

Magner Sanborn Office, Spokane, Washington

ICSquare Aperture ICE

ICE Round Aperture ICE

Art Gallery, Pensacola, FloridaArchitect: Sam Marshall ArchitectsPhotography: Karena Cawthon

round and square aperture


Recommended