Page 1 Introducing the Agilent 7000A QQQ-MS for GC Sunil Kulkarni Product Specialist Agilent Technologies
Transcript
Page 1: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 1

Introducing the Agilent 7000A QQQ-MS for GC

Sunil KulkarniProduct SpecialistAgilent Technologies

Page 2: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 2

Agilent GC/MS Portfolio

Smallest footprint, single GC column

Industry leading GC/MS System

5975C with 7890GC

5975VL with 6850GC

Page 3: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 3

Agilent GC/MS Portfolio

Smallest footprint, single GC column

Industry leading GC/MS System

5975C with 7890GC

5975VL with 6850GC

Introducing

Page 4: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 4

Agilent GC/MS Portfolio

Power of MRM7000A GC/MS/MS

Page 5: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 5

Agilent 7000A GC/MS/MS

7000A Width36 cm/14 inches

Only 2 inches wider than the 5975C MSD

Page 6: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 6

GC/MS Triple Quad (QQQ)

DetectorQuad 1Mass Analysis

Collision Gas (Ar, N2, He)

Quad 2Collision Cell

Ion Source•Ionize Quad 3

Mass Analysis

Carrier Gas (He, H2 )

Elements of a typical triple quadrupole MS system

Page 7: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 7

Agilent 7000 GC/MS/MS

DetectorQuad 1

Collision Gas (N2 )

Hexapole Collision Cell

Ion Source•Ionize Quad 2

The hexapole field has excellent transmission effic iency for precursor and product ions

Q1 Post-filter

Q2 Pre-filter

Page 8: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 8

What is MRM MS/MS?Multiple Reaction Monitoring

EI: many ions from the source

Q1 SIM isolate precursor ion

Page 9: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 9

What is MRM MS/MS?Multiple Reaction Monitoring

Product 3

Product 2

EI: many ions from the source

Product 1

EI-MS/MS

Q1 SIM isolate precursor ion

CID + Q2 SIM

Page 10: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 10

Why MS/MS?Lower detection limits by reducing noise

EI: many ions from the source

Q1 SIM isolate precursor before CID

chemical noise eliminated

Product ion signal often decreases, but the percentage decrease in noise is much larger for real samples; S/N and detection limits improve

Product 1Product 3

Product 2

CID +Q2 SIM

Product ion measured against zero chemical noise

Page 11: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 11

Why MS/MS?Greater Selectivity Than SIM

EI-SIMselectivity proportional to

spectral resolutionno selectivity against ions

with same m/z

interference

analyte

unit mass resolution

Page 12: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 12

Why MS/MS?Greater Selectivity Than SIM

PrecursorIon

Product 1Product 3

Product 2

EI-SIMselectivity proportional to

spectral resolutionno selectivity against ions

with same m/z

EI-MS/MSPrecursor selectivity same as SIM

High probability that at least one product ion will be a unique dissociation product

of the precursor BUT not the interferenceinterference

analyte

interference

The precursor ion should NOT be used for ion ratios or quantitation since the interferences will

be the same as the SIM ion

unit mass resolution

Page 13: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 13

Why a GC/MS/MS System?

Allows for the selective quantitation of target compounds in high chemical background samples

Better S/N in complex matrices than can be achieved by single quadrupole scan or SIM approaches.

Newer regulations in some markets specify analytical power commensurate with GC/MS/MS

Page 14: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 14

Why GC/MS/MS? A Picture Is Worth a Thousand Words

GC/MS/MS QQQ MRM

GC/MS Single Quad SIM

EI 100fg HCB in “DIRTY” Matrix

S/N: 116:1 RMS

100 fg HCB

MS SIM

MS/MS MRM A chromatographer’s dream: single peak on flat baseline

Page 15: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 15

Why GC/MS/MS? A Picture Is Worth a Thousand Words

GC/MS/MS QQQ MRM

GC/MS Single Quad SIM

EI 100fg HCB in “DIRTY” Matrix

S/N: 116:1 RMS

100 fg HCB

MS SIM

MS/MS MRM A chromatographer’s dream: single peak on flat baseline

Page 16: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 16

Technology

Agilent took the best technologies from their industry leading 597X Series GC/MSD:

– Heated monolithic gold plated quartz quadrupole

– Proven reliable high performance source design

– AUTOTUNE

and the 6410A LC/QQQ:

– Linear acceleration enhanced Collision Cell

– Wide Mass-Bandwidth QQQ ion optics

– Mass Hunter software

Page 17: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 17

Why Heated Quartz “Gold” Quads?

Unlike LC/MS, many high boiling neutral molecules enter the source and manifold of a GC/MS or GC/MS/MS

• Higher temperature reduces potential for contamination– 200C max

– Virtually eliminates the need to clean quads

• Low coefficient for thermal expansion for quartz– Stable structure during maintenance cycles (hot-cool-hot) for source

or detector

More stable tunes and methods over a longer period of time in real world sample environments

Page 18: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 18

GC/QQQ Analyzer

Inert, high temp source (same as 5975)

Triple-Axis detector (same as 5975)

Two gold plated quartz, hyperbolic analyzers (same as 5975)

Page 19: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 19

GC/QQQ Analyzer

Shown with shields for analyzers and collision cell

New high performance, hexapole collision cell with patent technology

EdwardsSplit Flow Turbo

Page 20: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 20

Analyzer Doors Open

Triple-Axis Detector

Inert, 350ºC Source

Page 21: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 21

Proven Inert Source Performance

Several thousands sources in current use

Stay-Clean design extends maintenance intervals with dirty samples

Source tune parameters in the Autotune file

Dual filament design reduces maintenance intervals

Page 22: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 22

EI Source Details

Partition between source and analyzer compartments

Page 23: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 23

High Performance Collision Cell Design

Linear acceleration design is optimized for high speed performance without ion ghosting or cross-talk

MRM speed to 500 MRMs/sec allows determination of more compounds per ion group

High sensitivity with wide mass bandwidth eliminates the need to “tune on your compound” for optimum sensitivity

“Helium Quenching” chemical noise reduction increases S/N

Page 24: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 24

Collision Cell Details

Quadrupole post-filter

Quadrupole pre-filter

Support cradle

(Cell housing and 2 rods removed for clarity)

Page 25: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 25

High Performance Triple-Axis Detector

Ultra low neutrals noise

Long life and high linearity

“Gain Normalization” corrects tune file for detector aging to allow repeatable long term method sensitivity

Same design as used in the 5975C GC/MSD

Page 26: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 26

Triple-Axis Detector

hyperbolic quartztransmission

quadrupoleanalyzer

triple channelelectron multiplier

high energy dynode

steering rod

ion beam

X

Y

OffsetZ

shield for secondary particles

Page 27: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 27

Autotune

Proprietary program tunes the source, mass analyzer, and detector for (as applicable):

• Ion transmission

• Mass axis calibration

• Mass resolution

• Detector gain vs Voltage

Autotune settings are saved with the method for repeatable method performance.

Manual Tune override is available

Page 28: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 28

Agilent 7000A GC/MS/MS OFN (octafluoronaphthalene) Sensitivity

272:241 Transition186:1 RMS S/N

100fg OFN

Page 29: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 29

One of the many innovations that led to this level of GC/MS/MS

sensitivity

Page 30: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 30

Collision Cell Gas Flows

1 ml/min N2 Collision Gas

Q1 Ions In

Collision Cell Ions OutHe* +

He* + N2 → N2+. + He + e-

N2+. + A → A+. + N2

Page 31: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 31

Collision Cell Gas Flows

1 ml/min N2 Collision Gas

Q1 Ions In

Collision Cell Ions OutHe* +

He* + He → 2 He + heat

He* + N2 → N2+. + He + e-

He Buffer Gas

Page 32: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 32

Effect of “Helium Quench”

S/N 341:1 Helium Quench Gas OFF

tested with hexachlorobenzene

Page 33: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 33

Effect of “Helium Quench”

S/N 1294:1 Helium Quench Gas ON

S/N 341:1 Helium Quench Gas OFF

Almost 4 XIncrease in S/N

Page 34: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 34

Effect of “Helium Quench”

Noise Comparison

S/N 1294:1 Helium Quench Gas ON

S/N 341:1 Helium Quench Gas OFF

tested with hexachlorobenzene

The increase in S/N was due to reduction of noise.

Page 35: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 35

MassHunter MS Workstation Software

Modern software interpretation of the proven industry standard GC/MS Chemstation platform

Single software platform for all Agilent MS Systems

• LC/SQ , LC/QQQ, LC/TOF, LC/QTOF

• GC/SQ, GC/QQQ

• ICP/MS

Page 36: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 36

GC/MS/MS Software Modules

Acquisition

Analysis

Excel Reporting

Page 37: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 37

MS/MS Acquisition Method Editor Dialog

Single window acquisition setup

Page 38: Introducing the Agilent 7000A QQQ-MS for GC · A Picture Is Worth a Thousand Words GC/MS/MS QQQ MRM GC/MS Single Quad SIM EI 100fg HCB in “DIRTY” Matrix S/N: 116:1 RMS 100 fg

Page 38

Agilent G7000A GC/QQQ

Outstanding sensitivity 100fg of OFN on column at 100:1 S/N RMS in MS/MS mode using AUTOTUNE parameters verified at customer installation.

1050 amu Mass Range

500 MRM/sec Speed

Reliable heated monolithic gold plated hyperbolic quadrupoles

Differentially pumped vacuum system

New Helium seeded collision cell technology

Agilent 7890 GC with Capillary Flow technology.

MassHunter Software


Recommended