+ All Categories
Home > Documents > Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is...

Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is...

Date post: 01-Aug-2021
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
4
Introducing the HOLOS IntraOp Wavefront Aberrometer Continuous real-time refractions during your cataract surgeries
Transcript
Page 1: Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is indisputable; imagine the possibility of no longer depending entirely upon pre-operative measurements

Introducing the HOLOS IntraOp™ Wavefront AberrometerContinuous real-time™ refractions during your cataract surgeries

Page 2: Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is indisputable; imagine the possibility of no longer depending entirely upon pre-operative measurements

Streaming video of intraoperative wavefront data to assess continuous real-time™ refraction changes during cataract surgery

Developed specifically for ophthalmology, the HOLOS IntraOp™ wavefront aberrometry utilizes patented HOLOS™ wavefront technology to provide:

The HOLOS IntraOp™ wavefront aberrometer fits seamlessly into cataract surgery workflow

» Efficient use of valuable surgical time: No need to stop surgery to change ambient light conditions, to acquire a refraction or adjust your working distance

» Compact design: Adaptable to 150mm, 175mm, or 200mm surgical microscope working distances

» Video archive of your entire procedure: Allows “instant replay” of your refractive cataract surgery

HOLOS IntraOp™: Continuous real-time™ refractions for cataract surgery

» Integration of all refractive data synchronized to real-time surgical video of the patient’s eye

» Continuous real-time™ refractive feedback for astigmatic correction when:

› Rotating toric IOLs

› Titrating relaxing limbal incisions

› Performing arcuate incisions with your femtosecond laser

» The accuracy of an advanced aberrometer-based technology (Sphere, Cylinder, Axis)1 to assess refractive data during the phakic, aphakic, and pseudophakic phases of surgery

» Simple, intuitive video interface helps maximize efficiency and minimize interruptions to your work flow

1. Data on file.

Page 3: Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is indisputable; imagine the possibility of no longer depending entirely upon pre-operative measurements

Gradually improving refraction detected by the HOLOS IntraOp™ wavefront aberrometer during rotational alignment of a toric IOL.

Continuous real-time™ verification of targeted refraction in every patient

The HOLOS IntraOp™ wavefront aberrometer displays qualitative and quantitative refractive data in real time, providing immediate feedback on how adjustments affect refraction.

» Continuous real-time™ measurements verify refraction during surgery

“The value of real-time...continuous wavefront aberrometry is indisputable; imagine the possibility of no longer depending entirely upon pre-operative measurements in obtaining axial length and keratometry. And confirming the target refraction on the operating table will change cataract surgery forever!”

- Robert H. Osher, MD

The HOLOS IntraOp™ System represents the future of intraoperative wavefront aberrometry

The HOLOS IntraOp™ wavefront aberrometer is engineered for the demands of modern refractive cataract surgery

“Premium IOLs are the patient value-added proposition that restores proper value to our skills as cataract surgeons and clinicians”.– David F. Chang, MD

“As refractive IOL technology improves, the demand for and success in delivering this value proposition will only increase”. – David F. Chang, MD

Page 4: Introducing the HOLOS IntraOp Wavefront Aberrometer · 2014. 2. 23. · aberrometry is indisputable; imagine the possibility of no longer depending entirely upon pre-operative measurements

HOLOS IntraOp™ is the only intraoperative wavefront aberrometer that provides continuous real-time™ refractions throughout cataract surgery

» Integrates refractive data with simultaneous real-time surgical video of the patient’s eye with an intuitive display

» Provides streaming data and video on astigmatism correction while rotating toric IOLs or titrating relaxing limbal incisions

» No need to stop to acquire a refraction

To learn more about the HOLOS IntraOp™ wavefront aberrometer, visit www.holos.com, or call (925) 463-7984.

5775 West Las Positas Boulevard, Pleasanton, CA USA 94588-4084www.claritymsi.com Main: (925) 463-7984 Fax: (925) 463-7992

© 20

13 C

larit

y M

edica

l Sys

tem

s, In

c. 99

-100

230

11/1

3

Technical Data

Wavefront Measurement Principle • Continuous Real-Time Sequential Wavefront Sensor

Spherical Power Range • -10D through +30D

Cylindrical Power Range • 8D

Measurement Data• Continuous real-time refractions throughout surgery• Qualitative and quantitative refractions overlaid on

video of the patient’s eye

Main Power Voltage • 90VAC ~ 240VAC 50/60Hz

Record and Playback Capability Of The Surgery

• Built-in DVR (Digital Video Recorder) for both wavefront data and patient video

Peripheral Equipment

• Touchscreen with integrated microprocessor• 10.2 inch full color screen with 1024 x 1080 resolution• Supports an external LCD screen with DVI/HDMI• Ethernet connectivity• Internal Storage = 1 Terabyte• Wireless keyboard with touchpad

US Patents • US7445335, US8356900, US8454162, US8506083 and additional patent applications pending.