of 68
5/26/2018 Introduction to GENEX Probe
1/68
www.huawei.com Huawei confidential, 2007-10
Huawei G N X Series
5/26/2018 Introduction to GENEX Probe
2/68
2
www.huawei.com Huawei confidential, 2007-102
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for Data Collection
Other Features
Case Study
5/26/2018 Introduction to GENEX Probe
3/68
3
www.huawei.com Huawei confidential, 2007-103
RNC
GENEX U-Net
Radio Network Planning Tool
Downlink + Uplink
GENEX Probe
GENEX Assistant
Test & Post-Process Tools
GENEX NastarNetwork Performance Analysis System
GENEX U-Net is a radio planning
tool that fully supports the
technologies of GSM,GPRS-EDGE,
CDMA IS95,
WCDMA/UMTS/HSDPA/HSUPA,
CDMA 2000/1xRTT/1xEVDO, and
TD-SCDMA wireless networks.
The GENEX Probe, network
optimization and drive test data
collection system, is an air
interface test tool for
WCDMA/HSDPA/HSUPA/GSM/GP
RS networks.
GENEX Assistant is a
professional wireless test data
post-processing software system.
GENEX Nastar is a platform for
monitoring and optimizing the
performance of
GSM/CDMA/WCDMA wireless
networks
Huawei GENEX Family
5/26/2018 Introduction to GENEX Probe
4/68
4
www.huawei.com Huawei confidential, 2007-104
Whole Flow Overview
Radio Network Planning Tool
Air Interface Test Tool and Post-
Processing Tool
Network Performance Analysis
Tool
Make full use of 2G resources
GENEX covers thenetwo rk l i fecyc le
5/26/2018 Introduction to GENEX Probe
5/68
5
www.huawei.com Huawei confidential, 2007-105
GENEX Partners in The World
Appl ied in the Huawei 2G and 3G planning and
opt imizat ion projects
Covers more than for ty coun tr ies, inc ludin g comm ercial
and pi lot of f ices
Assis ts the renowned operators in establ ishing and
opt imiz ing the network with hig h qual i ty .
The network operators include but no t l imited to: China
Mobi le, China Unicom , China Telecom, China Netcom ,
Vodafon e, PBTL, T-Mobile, Orang e, CellPlus ,
PCCW(Sund ay), Telecom, eMobile.
Aims at cons is tent ly prov id ing the cus tomers wi th
profession al and high- level solut ion s for network planning and
opt imizat ion.
Employed by netwo rk operators and designing ins t i tutes al l
over 26 provinc es and munic ipal i t ies
Integrates the exper iences of renowned operators, advancing
wi th cus tomers hand by hand.
5/26/2018 Introduction to GENEX Probe
6/68
6
www.huawei.com Huawei confidential, 2007-106
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for HSDPA / HSUPA DT Data Collection
Other Features
Case Study
5/26/2018 Introduction to GENEX Probe
7/68
7
www.huawei.com Huawei confidential, 2007-107
GENEX Probe drive test system
GARMIN Series
GPS
DTI Scanner
(Built-in GPS)Anritsu
Scanner
Trimble Series
GPS
Qualcomm TM6250/
6275
AT Command
Supported Mobile
Huawei WCDMA/HSDPA
Data card
*Support WCDMA
850/9001800/1900/2100Mhz
Equipment
Composition
support multi UE
carry out different
tests
simultaneously
Physical connection
Equipment bag
easy to carry and
suitable to be used in
the car
Huawei Dual Mode
Mobile(U626/U636)
5/26/2018 Introduction to GENEX Probe
8/68
8
www.huawei.com Huawei confidential, 2007-108
Contents
GENEX Overview
GENEX Probe General Workflow
Using Probe for Data Collection
Other Features
Case Study
5/26/2018 Introduction to GENEX Probe
9/68
9
www.huawei.com Huawei confidential, 2007-109
DT Operation Flow
1. Probe In stal lat io n.
2. P lug Probe dong le. (Must be ins tal led Shared Hardware key)
3. Connec t Hardware dev ice to the lap top .
4. Hardware dev ice conf igu rat ion .
5. System Configuration. (Set Log mask)
6. Test Plan Configuration.
7. Open the parameter widows you want to observe, such as RSCP and Ec/Io
in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.
8. Import engineering parameters, open Map window and import the related
Mapinfo file (.TAB). (Routes, Streets, etc)
9. Start Test, start recording.
10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start
Test first, then start to make call test.
5/26/2018 Introduction to GENEX Probe
10/68
10
www.huawei.com Huawei confidential, 2007-1010
Probe Interface
Workspace Area
Navigation
Area
Status Area
5/26/2018 Introduction to GENEX Probe
11/68
11
www.huawei.com Huawei confidential, 2007-1011
Probe Interface
Navigat ion View
5/26/2018 Introduction to GENEX Probe
12/68
12
www.huawei.com Huawei confidential, 2007-1012
Project Template
Project Template
Site Verification
Optimize
Benchmark
Acceptance
Customize
5/26/2018 Introduction to GENEX Probe
13/68
13
www.huawei.com Huawei confidential, 2007-1013
Hardware con f igurat ion
In Navigation Area
Hardware Configuration Before Test
!! Connect and config devices one by one
Hardware
Test
Delete
Device
Add
Device
C f f
5/26/2018 Introduction to GENEX Probe
14/68
14
www.huawei.com Huawei confidential, 2007-1014
Hardware con f igurat ion
PS domain tests (Data Service)need set Modem port.
Hardware Configuration Before Test
Hardware Configu rat ion Test
!!
HardwareTest
Devices status bar
H d C fi ti B f T t
5/26/2018 Introduction to GENEX Probe
15/68
15
www.huawei.com Huawei confidential, 2007-1015
Hardware con f igurat ion Window s port al locat ion (port num ber)
Hardware Configuration Before Test
H d C fi ti B f T t
5/26/2018 Introduction to GENEX Probe
16/68
16
www.huawei.com Huawei confidential, 2007-1016
Hardware con f igurat ion General Parameters Personal Main
Cities Test
Hardware Configuration Before Test
Device Type Model Baudrate Com Port Modem Port MSISDN
Scanner1 Scanner DTI WCDMA
(869.0-894.0 MHz)
115200 A definir A definir A definir
UE1 UE HUAWEI U1205 230400 A definir A definir A definir
UE2 UE HUAWEI U1205 230400 A definir A definir A definir
UE3 UE HUAWEI E270
Card***
230400 A definir A definir A definir
***No es el modelo pero funciona adecuadamente
H d C fi ti B f T t
5/26/2018 Introduction to GENEX Probe
17/68
17
www.huawei.com Huawei confidential, 2007-1017
Hardware con f igurat ion General Parameters Personal
Ac ceptance Test
Hardware Configuration Before Test
Device Type Model Baudrate Com Port Modem Port MSISDN
UE1 UE HUAWEI U1205 230400 A definir A definir A definir
UE2 UE HUAWEI U1205 230400 A definir A definir A definir
UE3 UE HUAWEI E270
Card***
230400 A definir A definir A definir
***No es el modelo pero funciona adecuadamente
DT O ti Fl
5/26/2018 Introduction to GENEX Probe
18/68
18
www.huawei.com Huawei confidential, 2007-1018
DT Operation Flow
1. Probe Installation.
2. Plug Probe dongle. (Must be installed SharedHardware key)
3. Connect Hardware device to the laptop.
4. Hardware device configuration.
5. Sys tem Con figurat ion . (Set Log mask )
6. Test Plan Configuration.
7. Open the parameter widows you want to observe, such as RSCP and Ec/Io
in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.
8. Import engineering parameters, open Map window and import the related
Mapinfo file (.TAB). (Routes, Streets, etc)
9. Start Test, start recording.
10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start
Test first, then start to make call test.
S t C fi ti B f T t
5/26/2018 Introduction to GENEX Probe
19/68
19
www.huawei.com Huawei confidential, 2007-1019
Log Mask sett ing
Set Log Mask
Set Log Name
Set Log file size
Location of saved logs
System Configuration Before Test
Log Mask Setting Before Test
5/26/2018 Introduction to GENEX Probe
20/68
20
www.huawei.com Huawei confidential, 2007-1020
Log Mask sett ing General Parameters Personal Main Cit ies
Test
Log Mask Setting Before Test
Device Limit Size Type Minutes Log File Directory
Scanner1 Limited Time (Minutes) 15 A convenir
UE1 Limited Time (Minutes) 15 A convenir
UE2 Limited Time (Minutes) 15 A convenir
UE3 Limited Time (Minutes) 15 A convenir
Log i tem Set t ing: Valores q ue aparecen por defecto
Log Mask Setting Before Test
5/26/2018 Introduction to GENEX Probe
21/68
21
www.huawei.com Huawei confidential, 2007-1021
Log Mask sett ing General Parameters Personal
Ac ceptance Test
Log Mask Setting Before Test
Device Limit Size Type Minutes Log File Directory
UE1 Limited Time (Minutes) 15 A convenir
UE2 Limited Time (Minutes) 15 A convenir
UE3 Limited Time (Minutes) 15 A convenir
Log i tem Set t ing: Valores q ue aparecen por defecto
S t C fi ti B f T t
5/26/2018 Introduction to GENEX Probe
22/68
22
www.huawei.com Huawei confidential, 2007-1022
System Configuration Before Test
Event sett ing
We can define the event we need through Event setting.
System Configuration Before Test
5/26/2018 Introduction to GENEX Probe
23/68
23
www.huawei.com Huawei confidential, 2007-1023
System Configuration Before Test
Alarm sett ing
We can define the alarm event we need through Alarm setting.
System Configuration Before Test
5/26/2018 Introduction to GENEX Probe
24/68
24
www.huawei.com Huawei confidential, 2007-1024
System Configuration Before Test
Other sett ing
We can set the Time Record Mode for a Log Packet, GPS synchronization Mode, DialUp Property for
Data Service, Display Filter for Log Data, Replay Mode for Event and Parameters for DTI Scanner
which we need through other setting.
DT Operation Flow
5/26/2018 Introduction to GENEX Probe
25/68
25
www.huawei.com Huawei confidential, 2007-1025
DT Operation Flow
1. Probe Installation.
2. Plug Probe dongle. (Must be installed SharedHardware key)
3. Connect Hardware device to the laptop.
4. Hardware device configuration.
5. System Configuration. (Set Log mask)
6. Tes t Plan Con fi gu rat ion .
7. Open the parameter widows you want to observe, such as RSCP and Ec/Io
in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.
8. Import engineering parameters, open Map window and import the related
Mapinfo file (.TAB). (Routes, Streets, etc)
9. Start Test, start recording.
10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start
Test first, then start to make call test.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
26/68
26
www.huawei.com Huawei confidential, 2007-1026
Test Plan Configuration
Control each device's behavior by selecting Test Plan items and setting property
parameters of each test items.
Test Plan Configuration Before Test
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
27/68
27
www.huawei.com Huawei confidential, 2007-1027
Test Plan Configuration Add & Config Scenar ios for UE
Set the Test Plan respectively for each device (UE/Scanner).
Test Plan Configuration Before Test
1. Select
Test Device
2. Add TestScenario
3. Add
Test Item
4. Set Test
Properties
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
28/68
28
www.huawei.com Huawei confidential, 2007-1028
Test Plan Configuration Auto Cal l scenar io
Test Plan Configuration Before Test
To modify
the scenario
To run
scenario
automatically
!!Check the enable
status
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
29/68
29
www.huawei.com Huawei confidential, 2007-1029
Test Plan Con figu ration Add & Con fig Scenar ios for DTI Scanner
1. Select
Test Item
2. Set Item
Property
Test Plan Configuration Before Test
!!Check the enable
status
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
30/68
30
www.huawei.com Huawei confidential, 2007-1030
Set Test Plan for UE
1. Voice call
Test Plan Configuration Before Test
Suggestion:When test ing voice cal l , do no t perform PS dialup on the Modem of the outg oing UE manual ly.
Otherwise, voice cal l maybe hangs up abnormal ly.
The UE that is performing PS services can serve as an incoming UE for Voice Cal l
or Video Phone test. Thus, the CS and PS concu rrent test can be performed o n the same UE.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
31/68
31
www.huawei.com Huawei confidential, 2007-1031
g
Parameters fo r Voice Call:
Call type
Continuou s Call:The call continues if it does not fail, drop, or hang up. If the call fails, drops,or hangs up, Probe waits for a call interval to originate another call.
Call by Call : cal l:The call lasts and waits for the predetermined calling duration and call
interval, and repeats for the times defined in call count.
Setup time:the maximum time for call setup. If the call cannot be setup within the defined period,the call setup fails.
Calling duration:the duration of one call, from call setup to call normal release. (apply only tocall by call)
Call interval:the time between two calls, from the previous call disconnection to the beginning ofthe next call.
Exceptional Interval The interval between the exceptional end of a call drop and thebeginning of the next call.
Count Mode:the limitations on the call number -> Finite / Infinite.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
32/68
32
www.huawei.com Huawei confidential, 2007-1032
Set Test Plan for UE
2. Ftp Upload / Ftp Download
Test Plan Configuration Before Test
Note: PS conn ect ion can be set up by o ne FTP Down load test i tem i f correct APN has
been set in UE.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
33/68
33
www.huawei.com Huawei confidential, 2007-1033
Parameters for Ftp Download / Ftp Upload:
Test Plan Configuration Before Test
User, Password:FTP user name and password. For anonymous login, also need to inputanonymous as username.
Remote File:Destination file address, input the detailed download path, such as,ftp://10.0.0.1/download/1.dat
Local File:Local path to save the download file, such as, C:\1.dat
MultiTask Count:When we use multi-threading download, set the number of threads here.
Test Interval (sec):The time interval between multi downloads. After finishing a download, waitfor several time, then start another download test.
FTP Count:the total number of ftp download test.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
34/68
34
www.huawei.com Huawei confidential, 2007-1034
Parameters for Ftp Download / Ftp Upload:
est a Co gu at o e o e est
Disconnection Mode:the mode of Disconnection, there are three choices:
Keep Disconn ected:Do not perform PDP context deactivation ( remain RRC connection) afterthe target files are loaded completely, just wait for interval time then continue next ftp downloadtest.
Disconn ect By Time:Perform PDP context deactivation periodically. The period for the PDPcontext deactivation is represented by the Valid FTP Durationparameter. If the target files are
not loaded completely within the predefined time, the loading result shows timeout. Probe
considers this loading as failure and initiates another PDP context deactivation in the next
loading.Disconn ect After Transfer Com plete:Each time when the file load is complete, PDP
context deactivation would be performed.
FTP QoS :Indicates the type of the traffic as: Background classConversational class
Interactive class
Streaming class
Subscribed class
FTP Upload:Parameters are the same with FTP downloads. Probe will upload the local file to the
destination path automatically.
**Make sure you have the authority to upload file before test.
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
35/68
35
www.huawei.com Huawei confidential, 2007-1035
g
About APN, QoS Sett ing
If leave APN, QoS parameters blank
Probe wont send the associated command to the UE if the parameters mentioned above is not set,
that is the UEs default setting will be maintained.
Methods for setting APN, QoS and their correlationship
1) Set by AT command in MODEM initial command2) Set by Probe in Test Plan
When both Probe and MODEM have APN and QoS information, because AT command in MODEM initial
command is send to UE more closely before PS connection setup, it will replace the information send to UE
by Probe. That is Probes setting doesnt work if AT command also exists in the MODEM initial command.
!!
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
36/68
36
www.huawei.com Huawei confidential, 2007-1036
g
About APN, QoS Sett ing
Method 1 (By Windows) Method 2 (by Probe)
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
37/68
37
www.huawei.com Huawei confidential, 2007-1037
Set Test Plan Config uration for DTI Scanner
g
!!
Check the enable
status
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
38/68
38
www.huawei.com Huawei confidential, 2007-1038
Test Plan Voice Call Short CallGeneral Parameters
Personal Main Cit ies and Acceptance Test
UE: UE1
Scenario Name: Short Call
Test Item : Voice Call
Dest inat ion: A definir
Call Typ e: Call by CallSetup Time(sec): 20
Cal l Durat ion(sec): 60
Call Interv al(sec): 10
Except io nal Interval(sec): 20
Count Mode: Infinite
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
39/68
39
www.huawei.com Huawei confidential, 2007-1039
Test Plan Voice Call Long CallGeneral Parameters
Personal Main Cit ies and Acceptance Test
UE: UE2
Scenario Name: Long Call
Test Item : Voice Call
Dest inat ion: A definir
Call Typ e:Call by Call
Setup Time(sec): 20
Cal l Durat ion(sec): 180
Call Interv al(sec): 10
Except io nal Interval(sec): 20
Count Mode: Infinite
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
40/68
40
www.huawei.com Huawei confidential, 2007-1040
Test Plan FTP Test Dow nload General Parameters Personal
Main Cit ies and Acceptance Test
UE: UE3
Scenario Name: FTP Download
Test Item : Ftp Download
Port : 21
User: A definir
Password: A definir
Remo te Fi le: A definir
Write Loc al Fi le: False
Mult iTask Coun t: 5
Test Interval(sec ): 5
Ftp Count : 999
Disconnect ion Mode: Disconnected after transfer completeTraff ic Class : Background Class
UL Max Rate(Kb ps):
DL Max Rate(Kb ps):
APN:
gprs.personal.com
Test Plan Configuration Before Test
5/26/2018 Introduction to GENEX Probe
41/68
41
www.huawei.com Huawei confidential, 2007-1041
Test Plan ScannerGeneral Parameters Personal Main
Cities Test
Scanner : Scanner1
I tem Name*: TopN Pilot Scan Enable:TRUE
Channel: A convenir Measure Rake Finger Coun t: FALSE
Scanner Type: A convenir Measu re SIR: TRUE
Pi lot Num ber(N): 10
Correlat ion Taps: 1
Chip Window Size: 32
PNThreshold(dB): -20.5
ScanRate(ms): 100
Measure Ec/Io: TRUE
Measure Time Offset: FALSE
Measure Agg regate Ec/Io: TRUEMeasure Delay Spread: FALSE
Measure Eps /Io: FALSE
Measure Ess /Io: FALSE
*Los demas Item Name (Pilot Scan, SpectrumAnalysis, CW, SCH Scan, RSSI 3.84M) deben
estar en FALSE en la opcion de Enable.
DT Operation Flow
5/26/2018 Introduction to GENEX Probe
42/68
42
www.huawei.com Huawei confidential, 2007-1042
1. Probe Installation.
2. Plug Probe dongle. (Must be installed SharedHardware key)
3. Connect Hardware device to the laptop.4. Hardware device configuration.
5. System Configuration. (Set Log mask)
6. Test Plan Configuration.
7. Open the parameter widows you want to observe, such as RSCP and
Ec/Io in Ac tive Set, Mon itor Set; HSDPA Serving Cell, thro ughput; RRCMessage, NAS Message, etc.
8. Import engineering parameters, open Map window and import the related
Mapinfo file (.TAB). (Routes, Streets, etc)
9. Start Test, start recording.
10. After the test finished, press "Stop Test button.
Notes: If you don't use "Test Plan" to start test automatically, please "Start
Test first, then start to make call test.
Parameter Window
5/26/2018 Introduction to GENEX Probe
43/68
43
www.huawei.com Huawei confidential, 2007-1043
Common u sed windows for HSDPA & R99
Parameter Window
5/26/2018 Introduction to GENEX Probe
44/68
44
www.huawei.com Huawei confidential, 2007-1044
WCDMA -Serving, Act ive Set & Neighbo r ing Cel ls
Display PSC, RSCP, Ec/Io for
active set, monitor set and detective
set
In the figure, rectangle legend
implicates active set data, circle
implicates monitor set data, and
triangle implicates detected set data.The data of the same type is
distinguished from each other with
different colors. Move the mouse to
a place to get the scrambling code
of the current point.
When the UE is in idle state, PSCin active set is about the cell where
the UE resides.
Parameter Window
5/26/2018 Introduction to GENEX Probe
45/68
45
www.huawei.com Huawei confidential, 2007-1045
WCDMA -Power Contro l
DL SIR, SIR
Target
Rx: UE received
power;
Tx: UE tx power
UL/DL transmit
power control
Parameter Window
5/26/2018 Introduction to GENEX Probe
46/68
46
www.huawei.com Huawei confidential, 2007-1046
WCDMA -WCDMA BLER
Displays BLER of different
transport channels.
In HSDPA connection mode, A-
DPCH's DL BLER is beingdisplayed.
Parameter Window
5/26/2018 Introduction to GENEX Probe
47/68
47
www.huawei.com Huawei confidential, 2007-1047
WCDMA -HSDPA Lin k Statist ic
Parameter Window
5/26/2018 Introduction to GENEX Probe
48/68
48
www.huawei.com Huawei confidential, 2007-1048
Message - MAC/RLC Messages
The MAC/RLC Messages window displays the messages about Media Access Control (MAC) and Radio
Link Control (RLC). The messages are visible only when the associated items in LogMask are selected.
Parameter Window
5/26/2018 Introduction to GENEX Probe
49/68
49
www.huawei.com Huawei confidential, 2007-1049
Message-RRC Messages
All the UEs or single UE are displayed on the window. The messages selected on the left
navigation tree are displayed. The detailed information is displayed by double-clicking on
the message.
Parameter Window
5/26/2018 Introduction to GENEX Probe
50/68
50
www.huawei.com Huawei confidential, 2007-1050
Message -NAS Messages
Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages
are displayed here as follow:
Parameter Window
5/26/2018 Introduction to GENEX Probe
51/68
51
www.huawei.com Huawei confidential, 2007-1051
Top N Pilot test
Scanner TopN Pilot & Spectrum Analysis
Parameter Window
5/26/2018 Introduction to GENEX Probe
52/68
52
www.huawei.com Huawei confidential, 2007-1052
Data Service - App Throughpu t
Display both UL and DL application layer data rate, NAS rate and TCP
retransmission rate.
Parameter Window
5/26/2018 Introduction to GENEX Probe
53/68
53
www.huawei.com Huawei confidential, 2007-1053
Data Servi ce -RLC Throughp ut
Display both UL and DL RLC layer throughput, UL PDU retransmission ratio
and DL PDU error ratio.
Parameter Window
5/26/2018 Introduction to GENEX Probe
54/68
54
www.huawei.com Huawei confidential, 2007-1054
Data Servi ce -FTP Service Quality Evaluation
Displays the associated indicators on the user plane of the FTP service, including
Login time, download time, download rate, etc.
Parameter Window
5/26/2018 Introduction to GENEX Probe
55/68
55
www.huawei.com Huawei confidential, 2007-1055
UE State
Displays the information of the mobile status and network parameters (cell, rnc, MCC, MNC, LAC, RAC)
Parameter Window
5/26/2018 Introduction to GENEX Probe
56/68
56
www.huawei.com Huawei confidential, 2007-1056
Information
Displays the information of hardware used and the test plan running
Parameter Window
5/26/2018 Introduction to GENEX Probe
57/68
57
www.huawei.com Huawei confidential, 2007-1057
Map Window
Parameter Window
5/26/2018 Introduction to GENEX Probe
58/68
58
www.huawei.com Huawei confidential, 2007-1058
Map Window Load WCDMA sites
5/26/2018 Introduction to GENEX Probe
59/68
59
www.huawei.com Huawei confidential, 2007-1059
www.huawei.com Huawei confidential, 2007-10
Contents
5/26/2018 Introduction to GENEX Probe
60/68
60
www.huawei.com Huawei confidential, 2007-1060
Case1. Inter-RAT handover test
Case2. WCDMA inter-frequency handover test
Case3. Multi-frequency Scanning
Case1. Inter-RAT handover test
5/26/2018 Introduction to GENEX Probe
61/68
61
www.huawei.com Huawei confidential, 2007-1061
Inter-RAT handov er test
Event observation Location of handover point
Case1. Inter-RAT handover test
5/26/2018 Introduction to GENEX Probe
62/68
62
www.huawei.com Huawei confidential, 2007-1062
Messages and measurementfrom different networks
Inter-RAT hando ver
Time of Handover
signaling
ase . n er- requency an overtest
WCDMA in ter frequency handover
5/26/2018 Introduction to GENEX Probe
63/68
63
www.huawei.com Huawei confidential, 2007-1063
The signal frequency in
active set is 2137.40
when the test starts
WCDMA in ter-f requency handover
Log file:
Signaling window
ase . n er- requency an overtest
WCDMA i t f h d
5/26/2018 Introduction to GENEX Probe
64/68
64
www.huawei.com Huawei confidential, 2007-1064
Signaling
observation before
handover
WCDMA inter-f requency handov er process
ase . n er- requency an overtest
WCDMA inter freq enc hando er process
5/26/2018 Introduction to GENEX Probe
65/68
65
www.huawei.com Huawei confidential, 2007-1065
Observe it again, and thefrequency handover to 2132.40
WCDMA inter-f requency handov er process
Case3. Multi-frequency Scanning
Simul taneous scanning of m ul t i
5/26/2018 Introduction to GENEX Probe
66/68
66
www.huawei.com Huawei confidential, 2007-1066
1. Set multi-frequency
Simul taneous scanning of mul t i -
f requency2. Scanned multi-
frequency
3. Select specified
frequency to observe it
Case3. Multi-frequency Scanning
5/26/2018 Introduction to GENEX Probe
67/68
67
www.huawei.com Huawei confidential, 2007-1067
Simultaneous observationof different frequencies
Simul taneous scanning of m ul t i -f requency
5/26/2018 Introduction to GENEX Probe
68/68
www.huawei.com Huawei confidential, 2007-10