  • 5/26/2018 Introduction to GENEX Probe

    1/68

    www.huawei.com Huawei confidential, 2007-10

    Huawei G N X Series

  • 5/26/2018 Introduction to GENEX Probe

    2/68

    2

    www.huawei.com Huawei confidential, 2007-102

    Contents

    GENEX Overview

    GENEX Probe General Workflow

    Using Probe for Data Collection

    Other Features

    Case Study

  • 5/26/2018 Introduction to GENEX Probe

    3/68

    3

    www.huawei.com Huawei confidential, 2007-103

    RNC

    GENEX U-Net

    Radio Network Planning Tool

    Downlink + Uplink

    GENEX Probe

    GENEX Assistant

    Test & Post-Process Tools

    GENEX NastarNetwork Performance Analysis System

    GENEX U-Net is a radio planning

    tool that fully supports the

    technologies of GSM,GPRS-EDGE,

    CDMA IS95,

    WCDMA/UMTS/HSDPA/HSUPA,

    CDMA 2000/1xRTT/1xEVDO, and

    TD-SCDMA wireless networks.

    The GENEX Probe, network

    optimization and drive test data

    collection system, is an air

    interface test tool for

    WCDMA/HSDPA/HSUPA/GSM/GP

    RS networks.

    GENEX Assistant is a

    professional wireless test data

    post-processing software system.

    GENEX Nastar is a platform for

    monitoring and optimizing the

    performance of

    GSM/CDMA/WCDMA wireless

    networks

    Huawei GENEX Family

  • 5/26/2018 Introduction to GENEX Probe

    4/68

    4

    www.huawei.com Huawei confidential, 2007-104

    Whole Flow Overview

    Radio Network Planning Tool

    Air Interface Test Tool and Post-

    Processing Tool

    Network Performance Analysis

    Tool

    Make full use of 2G resources

    GENEX covers thenetwo rk l i fecyc le

  • 5/26/2018 Introduction to GENEX Probe

    5/68

    5

    www.huawei.com Huawei confidential, 2007-105

    GENEX Partners in The World

    Appl ied in the Huawei 2G and 3G planning and

    opt imizat ion projects

    Covers more than for ty coun tr ies, inc ludin g comm ercial

    and pi lot of f ices

    Assis ts the renowned operators in establ ishing and

    opt imiz ing the network with hig h qual i ty .

    The network operators include but no t l imited to: China

    Mobi le, China Unicom , China Telecom, China Netcom ,

    Vodafon e, PBTL, T-Mobile, Orang e, CellPlus ,

    PCCW(Sund ay), Telecom, eMobile.

    Aims at cons is tent ly prov id ing the cus tomers wi th

    profession al and high- level solut ion s for network planning and

    opt imizat ion.

    Employed by netwo rk operators and designing ins t i tutes al l

    over 26 provinc es and munic ipal i t ies

    Integrates the exper iences of renowned operators, advancing

    wi th cus tomers hand by hand.

  • 5/26/2018 Introduction to GENEX Probe

    6/68

    6

    www.huawei.com Huawei confidential, 2007-106

    Contents

    GENEX Overview

    GENEX Probe General Workflow

    Using Probe for HSDPA / HSUPA DT Data Collection

    Other Features

    Case Study

  • 5/26/2018 Introduction to GENEX Probe

    7/68

    7

    www.huawei.com Huawei confidential, 2007-107

    GENEX Probe drive test system

    GARMIN Series

    GPS

    DTI Scanner

    (Built-in GPS)Anritsu

    Scanner

    Trimble Series

    GPS

    Qualcomm TM6250/

    6275

    AT Command

    Supported Mobile

    Huawei WCDMA/HSDPA

    Data card

    *Support WCDMA

    850/9001800/1900/2100Mhz

    Equipment

    Composition

    support multi UE

    carry out different

    tests

    simultaneously

    Physical connection

    Equipment bag

    easy to carry and

    suitable to be used in

    the car

    Huawei Dual Mode

    Mobile(U626/U636)

  • 5/26/2018 Introduction to GENEX Probe

    8/68

    8

    www.huawei.com Huawei confidential, 2007-108

    Contents

    GENEX Overview

    GENEX Probe General Workflow

    Using Probe for Data Collection

    Other Features

    Case Study

  • 5/26/2018 Introduction to GENEX Probe

    9/68

    9

    www.huawei.com Huawei confidential, 2007-109

    DT Operation Flow

    1. Probe In stal lat io n.

    2. P lug Probe dong le. (Must be ins tal led Shared Hardware key)

    3. Connec t Hardware dev ice to the lap top .

    4. Hardware dev ice conf igu rat ion .

    5. System Configuration. (Set Log mask)

    6. Test Plan Configuration.

    7. Open the parameter widows you want to observe, such as RSCP and Ec/Io

    in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.

    8. Import engineering parameters, open Map window and import the related

    Mapinfo file (.TAB). (Routes, Streets, etc)

    9. Start Test, start recording.

    10. After the test finished, press "Stop Test button.

    Notes: If you don't use "Test Plan" to start test automatically, please "Start

    Test first, then start to make call test.

  • 5/26/2018 Introduction to GENEX Probe

    10/68

    10

    www.huawei.com Huawei confidential, 2007-1010

    Probe Interface

    Workspace Area

    Navigation

    Area

    Status Area

  • 5/26/2018 Introduction to GENEX Probe

    11/68

    11

    www.huawei.com Huawei confidential, 2007-1011

    Probe Interface

    Navigat ion View

  • 5/26/2018 Introduction to GENEX Probe

    12/68

    12

    www.huawei.com Huawei confidential, 2007-1012

    Project Template

    Project Template

    Site Verification

    Optimize

    Benchmark

    Acceptance

    Customize

  • 5/26/2018 Introduction to GENEX Probe

    13/68

    13

    www.huawei.com Huawei confidential, 2007-1013

    Hardware con f igurat ion

    In Navigation Area

    Hardware Configuration Before Test

    !! Connect and config devices one by one

    Hardware

    Test

    Delete

    Device

    Add

    Device

    C f f

  • 5/26/2018 Introduction to GENEX Probe

    14/68

    14

    www.huawei.com Huawei confidential, 2007-1014

    Hardware con f igurat ion

    PS domain tests (Data Service)need set Modem port.

    Hardware Configuration Before Test

    Hardware Configu rat ion Test

    !!

    HardwareTest

    Devices status bar

    H d C fi ti B f T t

  • 5/26/2018 Introduction to GENEX Probe

    15/68

    15

    www.huawei.com Huawei confidential, 2007-1015

    Hardware con f igurat ion Window s port al locat ion (port num ber)

    Hardware Configuration Before Test

    H d C fi ti B f T t

  • 5/26/2018 Introduction to GENEX Probe

    16/68

    16

    www.huawei.com Huawei confidential, 2007-1016

    Hardware con f igurat ion General Parameters Personal Main

    Cities Test

    Hardware Configuration Before Test

    Device Type Model Baudrate Com Port Modem Port MSISDN

    Scanner1 Scanner DTI WCDMA

    (869.0-894.0 MHz)

    115200 A definir A definir A definir

    UE1 UE HUAWEI U1205 230400 A definir A definir A definir

    UE2 UE HUAWEI U1205 230400 A definir A definir A definir

    UE3 UE HUAWEI E270

    Card***

    230400 A definir A definir A definir

    ***No es el modelo pero funciona adecuadamente

    H d C fi ti B f T t

  • 5/26/2018 Introduction to GENEX Probe

    17/68

    17

    www.huawei.com Huawei confidential, 2007-1017

    Hardware con f igurat ion General Parameters Personal

    Ac ceptance Test

    Hardware Configuration Before Test

    Device Type Model Baudrate Com Port Modem Port MSISDN

    UE1 UE HUAWEI U1205 230400 A definir A definir A definir

    UE2 UE HUAWEI U1205 230400 A definir A definir A definir

    UE3 UE HUAWEI E270

    Card***

    230400 A definir A definir A definir

    ***No es el modelo pero funciona adecuadamente

    DT O ti Fl

  • 5/26/2018 Introduction to GENEX Probe

    18/68

    18

    www.huawei.com Huawei confidential, 2007-1018

    DT Operation Flow

    1. Probe Installation.

    2. Plug Probe dongle. (Must be installed SharedHardware key)

    3. Connect Hardware device to the laptop.

    4. Hardware device configuration.

    5. Sys tem Con figurat ion . (Set Log mask )

    6. Test Plan Configuration.

    7. Open the parameter widows you want to observe, such as RSCP and Ec/Io

    in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.

    8. Import engineering parameters, open Map window and import the related

    Mapinfo file (.TAB). (Routes, Streets, etc)

    9. Start Test, start recording.

    10. After the test finished, press "Stop Test button.

    Notes: If you don't use "Test Plan" to start test automatically, please "Start

    Test first, then start to make call test.

    S t C fi ti B f T t

  • 5/26/2018 Introduction to GENEX Probe

    19/68

    19

    www.huawei.com Huawei confidential, 2007-1019

    Log Mask sett ing

    Set Log Mask

    Set Log Name

    Set Log file size

    Location of saved logs

    System Configuration Before Test

    Log Mask Setting Before Test

  • 5/26/2018 Introduction to GENEX Probe

    20/68

    20

    www.huawei.com Huawei confidential, 2007-1020

    Log Mask sett ing General Parameters Personal Main Cit ies

    Test

    Log Mask Setting Before Test

    Device Limit Size Type Minutes Log File Directory

    Scanner1 Limited Time (Minutes) 15 A convenir

    UE1 Limited Time (Minutes) 15 A convenir

    UE2 Limited Time (Minutes) 15 A convenir

    UE3 Limited Time (Minutes) 15 A convenir

    Log i tem Set t ing: Valores q ue aparecen por defecto

    Log Mask Setting Before Test

  • 5/26/2018 Introduction to GENEX Probe

    21/68

    21

    www.huawei.com Huawei confidential, 2007-1021

    Log Mask sett ing General Parameters Personal

    Ac ceptance Test

    Log Mask Setting Before Test

    Device Limit Size Type Minutes Log File Directory

    UE1 Limited Time (Minutes) 15 A convenir

    UE2 Limited Time (Minutes) 15 A convenir

    UE3 Limited Time (Minutes) 15 A convenir

    Log i tem Set t ing: Valores q ue aparecen por defecto

    S t C fi ti B f T t

  • 5/26/2018 Introduction to GENEX Probe

    22/68

    22

    www.huawei.com Huawei confidential, 2007-1022

    System Configuration Before Test

    Event sett ing

    We can define the event we need through Event setting.

    System Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    23/68

    23

    www.huawei.com Huawei confidential, 2007-1023

    System Configuration Before Test

    Alarm sett ing

    We can define the alarm event we need through Alarm setting.

    System Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    24/68

    24

    www.huawei.com Huawei confidential, 2007-1024

    System Configuration Before Test

    Other sett ing

    We can set the Time Record Mode for a Log Packet, GPS synchronization Mode, DialUp Property for

    Data Service, Display Filter for Log Data, Replay Mode for Event and Parameters for DTI Scanner

    which we need through other setting.

    DT Operation Flow

  • 5/26/2018 Introduction to GENEX Probe

    25/68

    25

    www.huawei.com Huawei confidential, 2007-1025

    DT Operation Flow

    1. Probe Installation.

    2. Plug Probe dongle. (Must be installed SharedHardware key)

    3. Connect Hardware device to the laptop.

    4. Hardware device configuration.

    5. System Configuration. (Set Log mask)

    6. Tes t Plan Con fi gu rat ion .

    7. Open the parameter widows you want to observe, such as RSCP and Ec/Io

    in Active Set, Monitor Set; HSDPA Serving Cell, throughput; RRC Message,NAS Message, etc.

    8. Import engineering parameters, open Map window and import the related

    Mapinfo file (.TAB). (Routes, Streets, etc)

    9. Start Test, start recording.

    10. After the test finished, press "Stop Test button.

    Notes: If you don't use "Test Plan" to start test automatically, please "Start

    Test first, then start to make call test.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    26/68

    26

    www.huawei.com Huawei confidential, 2007-1026

    Test Plan Configuration

    Control each device's behavior by selecting Test Plan items and setting property

    parameters of each test items.

    Test Plan Configuration Before Test

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    27/68

    27

    www.huawei.com Huawei confidential, 2007-1027

    Test Plan Configuration Add & Config Scenar ios for UE

    Set the Test Plan respectively for each device (UE/Scanner).

    Test Plan Configuration Before Test

    1. Select

    Test Device

    2. Add TestScenario

    3. Add

    Test Item

    4. Set Test

    Properties

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    28/68

    28

    www.huawei.com Huawei confidential, 2007-1028

    Test Plan Configuration Auto Cal l scenar io

    Test Plan Configuration Before Test

    To modify

    the scenario

    To run

    scenario

    automatically

    !!Check the enable

    status

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    29/68

    29

    www.huawei.com Huawei confidential, 2007-1029

    Test Plan Con figu ration Add & Con fig Scenar ios for DTI Scanner

    1. Select

    Test Item

    2. Set Item

    Property

    Test Plan Configuration Before Test

    !!Check the enable

    status

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    30/68

    30

    www.huawei.com Huawei confidential, 2007-1030

    Set Test Plan for UE

    1. Voice call

    Test Plan Configuration Before Test

    Suggestion:When test ing voice cal l , do no t perform PS dialup on the Modem of the outg oing UE manual ly.

    Otherwise, voice cal l maybe hangs up abnormal ly.

    The UE that is performing PS services can serve as an incoming UE for Voice Cal l

    or Video Phone test. Thus, the CS and PS concu rrent test can be performed o n the same UE.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    31/68

    31

    www.huawei.com Huawei confidential, 2007-1031

    g

    Parameters fo r Voice Call:

    Call type

    Continuou s Call:The call continues if it does not fail, drop, or hang up. If the call fails, drops,or hangs up, Probe waits for a call interval to originate another call.

    Call by Call : cal l:The call lasts and waits for the predetermined calling duration and call

    interval, and repeats for the times defined in call count.

    Setup time:the maximum time for call setup. If the call cannot be setup within the defined period,the call setup fails.

    Calling duration:the duration of one call, from call setup to call normal release. (apply only tocall by call)

    Call interval:the time between two calls, from the previous call disconnection to the beginning ofthe next call.

    Exceptional Interval The interval between the exceptional end of a call drop and thebeginning of the next call.

    Count Mode:the limitations on the call number -> Finite / Infinite.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    32/68

    32

    www.huawei.com Huawei confidential, 2007-1032

    Set Test Plan for UE

    2. Ftp Upload / Ftp Download

    Test Plan Configuration Before Test

    Note: PS conn ect ion can be set up by o ne FTP Down load test i tem i f correct APN has

    been set in UE.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    33/68

    33

    www.huawei.com Huawei confidential, 2007-1033

    Parameters for Ftp Download / Ftp Upload:

    Test Plan Configuration Before Test

    User, Password:FTP user name and password. For anonymous login, also need to inputanonymous as username.

    Remote File:Destination file address, input the detailed download path, such as,ftp://10.0.0.1/download/1.dat

    Local File:Local path to save the download file, such as, C:\1.dat

    MultiTask Count:When we use multi-threading download, set the number of threads here.

    Test Interval (sec):The time interval between multi downloads. After finishing a download, waitfor several time, then start another download test.

    FTP Count:the total number of ftp download test.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    34/68

    34

    www.huawei.com Huawei confidential, 2007-1034

    Parameters for Ftp Download / Ftp Upload:

    est a Co gu at o e o e est

    Disconnection Mode:the mode of Disconnection, there are three choices:

    Keep Disconn ected:Do not perform PDP context deactivation ( remain RRC connection) afterthe target files are loaded completely, just wait for interval time then continue next ftp downloadtest.

    Disconn ect By Time:Perform PDP context deactivation periodically. The period for the PDPcontext deactivation is represented by the Valid FTP Durationparameter. If the target files are

    not loaded completely within the predefined time, the loading result shows timeout. Probe

    considers this loading as failure and initiates another PDP context deactivation in the next

    loading.Disconn ect After Transfer Com plete:Each time when the file load is complete, PDP

    context deactivation would be performed.

    FTP QoS :Indicates the type of the traffic as: Background classConversational class

    Interactive class

    Streaming class

    Subscribed class

    FTP Upload:Parameters are the same with FTP downloads. Probe will upload the local file to the

    destination path automatically.

    **Make sure you have the authority to upload file before test.

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    35/68

    35

    www.huawei.com Huawei confidential, 2007-1035

    g

    About APN, QoS Sett ing

    If leave APN, QoS parameters blank

    Probe wont send the associated command to the UE if the parameters mentioned above is not set,

    that is the UEs default setting will be maintained.

    Methods for setting APN, QoS and their correlationship

    1) Set by AT command in MODEM initial command2) Set by Probe in Test Plan

    When both Probe and MODEM have APN and QoS information, because AT command in MODEM initial

    command is send to UE more closely before PS connection setup, it will replace the information send to UE

    by Probe. That is Probes setting doesnt work if AT command also exists in the MODEM initial command.

    !!

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    36/68

    36

    www.huawei.com Huawei confidential, 2007-1036

    g

    About APN, QoS Sett ing

    Method 1 (By Windows) Method 2 (by Probe)

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    37/68

    37

    www.huawei.com Huawei confidential, 2007-1037

    Set Test Plan Config uration for DTI Scanner

    g

    !!

    Check the enable

    status

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    38/68

    38

    www.huawei.com Huawei confidential, 2007-1038

    Test Plan Voice Call Short CallGeneral Parameters

    Personal Main Cit ies and Acceptance Test

    UE: UE1

    Scenario Name: Short Call

    Test Item : Voice Call

    Dest inat ion: A definir

    Call Typ e: Call by CallSetup Time(sec): 20

    Cal l Durat ion(sec): 60

    Call Interv al(sec): 10

    Except io nal Interval(sec): 20

    Count Mode: Infinite

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    39/68

    39

    www.huawei.com Huawei confidential, 2007-1039

    Test Plan Voice Call Long CallGeneral Parameters

    Personal Main Cit ies and Acceptance Test

    UE: UE2

    Scenario Name: Long Call

    Test Item : Voice Call

    Dest inat ion: A definir

    Call Typ e:Call by Call

    Setup Time(sec): 20

    Cal l Durat ion(sec): 180

    Call Interv al(sec): 10

    Except io nal Interval(sec): 20

    Count Mode: Infinite

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    40/68

    40

    www.huawei.com Huawei confidential, 2007-1040

    Test Plan FTP Test Dow nload General Parameters Personal

    Main Cit ies and Acceptance Test

    UE: UE3

    Scenario Name: FTP Download

    Test Item : Ftp Download

    Port : 21

    User: A definir

    Password: A definir

    Remo te Fi le: A definir

    Write Loc al Fi le: False

    Mult iTask Coun t: 5

    Test Interval(sec ): 5

    Ftp Count : 999

    Disconnect ion Mode: Disconnected after transfer completeTraff ic Class : Background Class

    UL Max Rate(Kb ps):

    DL Max Rate(Kb ps):

    APN:

    gprs.personal.com

    Test Plan Configuration Before Test

  • 5/26/2018 Introduction to GENEX Probe

    41/68

    41

    www.huawei.com Huawei confidential, 2007-1041

    Test Plan ScannerGeneral Parameters Personal Main

    Cities Test

    Scanner : Scanner1

    I tem Name*: TopN Pilot Scan Enable:TRUE

    Channel: A convenir Measure Rake Finger Coun t: FALSE

    Scanner Type: A convenir Measu re SIR: TRUE

    Pi lot Num ber(N): 10

    Correlat ion Taps: 1

    Chip Window Size: 32

    PNThreshold(dB): -20.5

    ScanRate(ms): 100

    Measure Ec/Io: TRUE

    Measure Time Offset: FALSE

    Measure Agg regate Ec/Io: TRUEMeasure Delay Spread: FALSE

    Measure Eps /Io: FALSE

    Measure Ess /Io: FALSE

    *Los demas Item Name (Pilot Scan, SpectrumAnalysis, CW, SCH Scan, RSSI 3.84M) deben

    estar en FALSE en la opcion de Enable.

    DT Operation Flow

  • 5/26/2018 Introduction to GENEX Probe

    42/68

    42

    www.huawei.com Huawei confidential, 2007-1042

    1. Probe Installation.

    2. Plug Probe dongle. (Must be installed SharedHardware key)

    3. Connect Hardware device to the laptop.4. Hardware device configuration.

    5. System Configuration. (Set Log mask)

    6. Test Plan Configuration.

    7. Open the parameter widows you want to observe, such as RSCP and

    Ec/Io in Ac tive Set, Mon itor Set; HSDPA Serving Cell, thro ughput; RRCMessage, NAS Message, etc.

    8. Import engineering parameters, open Map window and import the related

    Mapinfo file (.TAB). (Routes, Streets, etc)

    9. Start Test, start recording.

    10. After the test finished, press "Stop Test button.

    Notes: If you don't use "Test Plan" to start test automatically, please "Start

    Test first, then start to make call test.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    43/68

    43

    www.huawei.com Huawei confidential, 2007-1043

    Common u sed windows for HSDPA & R99

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    44/68

    44

    www.huawei.com Huawei confidential, 2007-1044

    WCDMA -Serving, Act ive Set & Neighbo r ing Cel ls

    Display PSC, RSCP, Ec/Io for

    active set, monitor set and detective

    set

    In the figure, rectangle legend

    implicates active set data, circle

    implicates monitor set data, and

    triangle implicates detected set data.The data of the same type is

    distinguished from each other with

    different colors. Move the mouse to

    a place to get the scrambling code

    of the current point.

    When the UE is in idle state, PSCin active set is about the cell where

    the UE resides.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    45/68

    45

    www.huawei.com Huawei confidential, 2007-1045

    WCDMA -Power Contro l

    DL SIR, SIR

    Target

    Rx: UE received

    power;

    Tx: UE tx power

    UL/DL transmit

    power control

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    46/68

    46

    www.huawei.com Huawei confidential, 2007-1046

    WCDMA -WCDMA BLER

    Displays BLER of different

    transport channels.

    In HSDPA connection mode, A-

    DPCH's DL BLER is beingdisplayed.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    47/68

    47

    www.huawei.com Huawei confidential, 2007-1047

    WCDMA -HSDPA Lin k Statist ic

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    48/68

    48

    www.huawei.com Huawei confidential, 2007-1048

    Message - MAC/RLC Messages

    The MAC/RLC Messages window displays the messages about Media Access Control (MAC) and Radio

    Link Control (RLC). The messages are visible only when the associated items in LogMask are selected.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    49/68

    49

    www.huawei.com Huawei confidential, 2007-1049

    Message-RRC Messages

    All the UEs or single UE are displayed on the window. The messages selected on the left

    navigation tree are displayed. The detailed information is displayed by double-clicking on

    the message.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    50/68

    50

    www.huawei.com Huawei confidential, 2007-1050

    Message -NAS Messages

    Whatever mode UE is in, WCDMA, HSDPA or GSM, all the NAS messages

    are displayed here as follow:

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    51/68

    51

    www.huawei.com Huawei confidential, 2007-1051

    Top N Pilot test

    Scanner TopN Pilot & Spectrum Analysis

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    52/68

    52

    www.huawei.com Huawei confidential, 2007-1052

    Data Service - App Throughpu t

    Display both UL and DL application layer data rate, NAS rate and TCP

    retransmission rate.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    53/68

    53

    www.huawei.com Huawei confidential, 2007-1053

    Data Servi ce -RLC Throughp ut

    Display both UL and DL RLC layer throughput, UL PDU retransmission ratio

    and DL PDU error ratio.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    54/68

    54

    www.huawei.com Huawei confidential, 2007-1054

    Data Servi ce -FTP Service Quality Evaluation

    Displays the associated indicators on the user plane of the FTP service, including

    Login time, download time, download rate, etc.

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    55/68

    55

    www.huawei.com Huawei confidential, 2007-1055

    UE State

    Displays the information of the mobile status and network parameters (cell, rnc, MCC, MNC, LAC, RAC)

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    56/68

    56

    www.huawei.com Huawei confidential, 2007-1056

    Information

    Displays the information of hardware used and the test plan running

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    57/68

    57

    www.huawei.com Huawei confidential, 2007-1057

    Map Window

    Parameter Window

  • 5/26/2018 Introduction to GENEX Probe

    58/68

    58

    www.huawei.com Huawei confidential, 2007-1058

    Map Window Load WCDMA sites

  • 5/26/2018 Introduction to GENEX Probe

    59/68

    59

    www.huawei.com Huawei confidential, 2007-1059

    www.huawei.com Huawei confidential, 2007-10

    Contents

  • 5/26/2018 Introduction to GENEX Probe

    60/68

    60

    www.huawei.com Huawei confidential, 2007-1060

    Case1. Inter-RAT handover test

    Case2. WCDMA inter-frequency handover test

    Case3. Multi-frequency Scanning

    Case1. Inter-RAT handover test

  • 5/26/2018 Introduction to GENEX Probe

    61/68

    61

    www.huawei.com Huawei confidential, 2007-1061

    Inter-RAT handov er test

    Event observation Location of handover point

    Case1. Inter-RAT handover test

  • 5/26/2018 Introduction to GENEX Probe

    62/68

    62

    www.huawei.com Huawei confidential, 2007-1062

    Messages and measurementfrom different networks

    Inter-RAT hando ver

    Time of Handover

    signaling

    ase . n er- requency an overtest

    WCDMA in ter frequency handover

  • 5/26/2018 Introduction to GENEX Probe

    63/68

    63

    www.huawei.com Huawei confidential, 2007-1063

    The signal frequency in

    active set is 2137.40

    when the test starts

    WCDMA in ter-f requency handover

    Log file:

    Signaling window

    ase . n er- requency an overtest

    WCDMA i t f h d

  • 5/26/2018 Introduction to GENEX Probe

    64/68

    64

    www.huawei.com Huawei confidential, 2007-1064

    Signaling

    observation before

    handover

    WCDMA inter-f requency handov er process

    ase . n er- requency an overtest

    WCDMA inter freq enc hando er process

  • 5/26/2018 Introduction to GENEX Probe

    65/68

    65

    www.huawei.com Huawei confidential, 2007-1065

    Observe it again, and thefrequency handover to 2132.40

    WCDMA inter-f requency handov er process

    Case3. Multi-frequency Scanning

    Simul taneous scanning of m ul t i

  • 5/26/2018 Introduction to GENEX Probe

    66/68

    66

    www.huawei.com Huawei confidential, 2007-1066

    1. Set multi-frequency

    Simul taneous scanning of mul t i -

    f requency2. Scanned multi-

    frequency

    3. Select specified

    frequency to observe it

    Case3. Multi-frequency Scanning

  • 5/26/2018 Introduction to GENEX Probe

    67/68

    67

    www.huawei.com Huawei confidential, 2007-1067

    Simultaneous observationof different frequencies

    Simul taneous scanning of m ul t i -f requency

  • 5/26/2018 Introduction to GENEX Probe

    68/68

    www.huawei.com Huawei confidential, 2007-10


Recommended