15
781$541$5060 www.pacerepresentatives.com Reference wall Basis of Design Package. Registered design professional in responsible charge to review prior to use. Page 1 of 1 Rev: 2016@05@31 Opaque Envelope Basis of Design Rainscreen Cladding w/ DensElement Inverted Wall System Rainscreen Cladding with Inverted Wall System and Metal Stud Backup Item Component Thickness Manufacturer Product 1 Interior Finish (vapor permeable) 0” $ $ 2 Interior Gypsum Board 5/8” $ Type X 3 Metal Stud (18 GA. Min. @16” O.C.) 6” $ $ 3A 1 Stud Cavity Insulation (Optional) 6” $ Fiberglass Batt 4 1 Continuous Insulation 2 1/2” Dow Styrofoam Ultra 5 Exterior Gypsum Sheathing 5/8” Georgia Pacific DensElement 6 Liquid Flashing Prosoco R$Guard FastFlash 7 Cladding Attachment System 1 1/2” Knight Wall CI or HCI System 8 1 Rainscreen Cladding $ $ NFPA 285 Compliant Total D 1 Product recommendations are based on Type I@IV construction requiring NFPA 285 assembly acceptance criteria compliance per IBC 2015 Section 2603.5.5. Assembly Performance: (proposed assembly U@Factors are approximately 8%|33% better than code and have 92%|79% thermal effectiveness) Clear Wall Code Requirement (IECC 2015 – Metal Framed) Project Requirement (if different) Proposed Design R$Value: a R$13 + R$7.5ci N/A R$14ci | R$19 + R$14ci Total R$Value: N/A N/A R$18.75 | R$36.70 Effective R$Value: c N/A N/A R$17.23 | R$28.90 Design U$Factor: a, b U$0.064 N/A U$0.059 | U$0.043 Effective U$Factor: c N/A N/A U$0.058 | U$0.035 Assembly Air Permeability 0.04 cfm/ft 2 @75Pa N/A 0.01 cfm/ft 2 @75Pa a Clear wall meets energy code and project thermal requirements without stud cavity insulation. b Clear wall U@Factor is based on the stud size & spacing noted above and is calculated per IECC 2015 & ASHRAE 90.1@2013 Appendix A. c Clear wall effective assembly thermal performance is based on stud size & spacing above, manufacturer literature and industry studies on the thermal performance of façades. Attachments: Typical Clear Wall Detail Assembly Dew Point Calculation(s) Product Literature
Transcript
Page 1: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

!

781$541$5060) www.pacerepresentatives.com)Reference'wall'Basis'of'Design'Package.''Registered'design'professional'in'responsible'charge'to'review'prior'to'use.'

Page)1)of)1)Rev:'2016@05@31'

!

Opaque'Envelope'Basis'of'Design'Rainscreen)Cladding)w/)DensElement)Inverted)Wall)System))

Rainscreen'Cladding'with'Inverted'Wall'System'and'Metal'Stud'Backup''

Item' Component' Thickness' Manufacturer' Product'1) Interior)Finish)(vapor'permeable)) 0”) $) $!2) Interior)Gypsum)Board) 5/8”) $) Type)X)

3) Metal)Stud)(18'GA.'Min.'@16”'O.C.)) 6”) $) $!3A1) Stud)Cavity)Insulation)(Optional)) )6”) $) Fiberglass)Batt))

41) Continuous)Insulation) 2)1/2”) Dow) Styrofoam)Ultra)

5) Exterior)Gypsum)Sheathing) 5/8”) Georgia)Pacific) DensElement)

6) Liquid)Flashing) ) Prosoco) R$Guard)FastFlash)

7) Cladding)Attachment)System) 1)1/2”) Knight)Wall) CI)or)HCI)System)

81) Rainscreen)Cladding) $) $) NFPA)285)Compliant)

) Total' D' ) )1'Product'recommendations'are'based'on'Type'I@IV'construction'requiring'NFPA'285'assembly'acceptance'criteria'compliance'per'IBC'2015'Section'2603.5.5.''')

Assembly'Performance:'(proposed'assembly'U@Factors'are'approximately'8%|33%'better'than'code'and'have'92%|79%'thermal'effectiveness)'

Clear'Wall' Code'Requirement'(IECC'2015'–'Metal'Framed)'

Project'Requirement'(if'different)' Proposed'

Design)R$Value:)a) R$13)+)R$7.5ci) N/A) R$14ci)|)R$19)+)R$14ci)

Total)R$Value:) N/A) N/A) R$18.75)|)R$36.70)

Effective)R$Value:)c) N/A) N/A) R$17.23)|)R$28.90)

Design)U$Factor:)a,)b) U$0.064) N/A! U$0.059)|)U$0.043)

Effective)U$Factor:)c) N/A) N/A! U$0.058)|)U$0.035)

Assembly)Air)Permeability) 0.04)cfm/ft2)@75Pa) N/A! 0.01)cfm/ft2)@75Pa)a'Clear'wall'meets'energy'code'and'project'thermal'requirements'without'stud'cavity'insulation.'''b'Clear'wall'U@Factor'is'based'on'the'stud'size'&'spacing'noted'above'and'is'calculated'per'IECC'2015'&'ASHRAE'90.1@2013'Appendix'A.'c'Clear'wall'effective'assembly'thermal'performance'is'based'on'stud'size'&'spacing'above,'manufacturer'literature'and'industry'studies'on'the'thermal'performance'of'façades.')

Attachments:)

•) Typical)Clear)Wall)Detail)

•) Assembly)Dew)Point)Calculation(s))

•) Product)Literature)

Page 2: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+
Page 3: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+
Page 4: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+
Page 5: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+
Page 6: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+
Page 7: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

1. PRODUCT NAMESTYROFOAM™ Brand Ultra SL Insulation

2. MANUFACTURERThe Dow Chemical Company Dow Building Solutions 200 Larkin Midland, MI 48674 1-866-583-BLUE (2583) Fax 1-989-832-1465

3. PRODUCT DESCRIPTIONBasic UseSTYROFOAM™ Brand Ultra SL Insulation is a moisture-resistant, durable and lightweight extruded polystyrene foam board with shiplap edges designed specifically to be used as a continuous insulation (ci) and installed over block, concrete or metal stud backup behind masonry or stone veneers. Manufactured with a patented carbon-black technology, STYROFOAM™ Brand Ultra SL Insulation features an R-value of 5.6 per inch (RSI of 0.97 per 25 mm),1 the highest of all extruded polystyrene foam insulation products. Its closed-cell structure offers advanced long-term thermal performance and moisture control. STYROFOAM™ Brand Ultra SL Insulation with shiplap edges maximizes the thermal performance of the wall assembly.

STYROFOAM™ Brand Ultra SL Insulation — when tested with WEATHERMATE™ Flashing taped joints, penetrations and transitions —complies with ASTM E2178 and ASTM E2357 Assembly Air Barrier tests. It is also an approved air barrier assembly by the Air Barrier Association of America (ABAA). These tests are included as acceptable compliance tests in meeting the continuous Air Barrier Standard that has been approved by the ASHRAE 90.1 committee for inclusion into the 90.1-2010 standard. This wall assembly was tested in accordance with the ASTM E331 Water Penetration Test and passed.

4. TECHNICAL DATAApplicable StandardsSTYROFOAM™ Brand Ultra SL Insulation meets ASTM C578 Type IV Standard Specification for Rigid Cellular Polystyrene Insulation. Applicable standards include:

State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Compressive Properties of Rigid Cellular Plastics

Vapor Transmission of Materials

of Linear Thermal Expansion of Plastics Between -30˚C and 30˚C With a Vitreous Silica Dilatometer

Load and Flexural Properties of Block-Type Thermal Insulation

Response of Rigid Cellular Plastics to Thermal and Humid Aging

Absorption of Rigid Cellular Plastics

When tested with WEATHERMATE™ Flashing or GREAT STUFF PRO™ Insulating Foam Sealant2 around joint treatments, penetrations and transitions, STYROFOAM™ Brand Ultra SL Insulation meets the following standards:

Block and Steel Stud — Passed

Air Barrier Association of America (ABAA)

3

Code ComplianceSTYROFOAM™ Brand Ultra SL Insulation complies with the following codes:

insulation; see ICC-ES ESR 2142

Classified, see Classification Certificate D369

Contact your Dow sales representative or local

Physical PropertiesSTYROFOAM™ Brand Ultra SL Insulation exhibits the properties and characteristics indicated in Table 2 when tested as represented.

1 Aged R-value (RSI) at 75°F (24°C) mean temp. R means resistance to heat flow. The higher the R-value or RSI, the greater the insulating power. Refer to Table 2 for thermal resistance at other mean temperatures.2 Consult label and Material Safety Data Sheet carefully before use. 3 Meets NFPA 285 per Section 2603.5.5 of the building code. For specific assemblies, see code report ESR 2142.

TABLE 1: U.S. SIZES, R-VALUES AND EDGE TREATMENTS FOR STYROFOAM™ BRAND ULTRA SL EXTRUDED POLYSTYRENE FOAM INSULATION

NOMINAL BOARD THICKNESS,1 IN R-VALUE2 BOARD SIZE,3 IN EDGE TREATMENT1.75 10.0 4' x 8' 8' SHIPLAP

2.125 12.0 4' x 8' 8' SHIPLAP

2.5 14.0 4' x 8' 8' SHIPLAP

3.0 16.8 4' x 8' 8' SHIPLAP

2 R means resistance to heat flow. The higher the R-value, the greater the insulating power. R-values are expressed in ft2 R-value determined by ASTM C518.

3 4' x 10', 4' x 12' lengths available through special order.

STYROFOAM™ Brand Ultra SL Extruded Polystyrene Foam InsulationProduct Information — Commercial — U.S.

Page 8: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

Do not leave STYROFOAM™ Brand Ultra SL Insulation exposed to direct sunlight for more than 90 days. Consult a Dow representative if exposure is expected to be longer than 90 days. Prolonged exposure to ultraviolet radiation may cause the surface of STYROFOAM™ Brand Ultra SL Insulation to become faded and dusty. The surface degradation will have no measurable effect on the insulating value of the plastic foam unless the deterioration is allowed to continue until actual foam thickness is lost. Since the dust would impair the performance of adhesives and finishes, dusty surfaces should be brushed off before these products are applied. A light-

used if excessive solar exposure is expected. When stored outdoors, keep insulation boards tarped or covered to protect from weather and weighted down to prevent boards from being blown around by the wind.

Environmental DataSTYROFOAM™ Brand Ultra SL Insulation is hydrochlorofluorocarbon-free (HCFC-free) with zero ozone-depletion potential. STYROFOAM™ Brand Ultra SL Insulation is reusable in many applications.

Fire InformationSTYROFOAM™ Brand Ultra SL Insulation is combustible; protect from high heat sources. A protective barrier or thermal barrier may be

code. For more information, consult MSDS, call Dow at 1-866-583-BLUE (2583) or contact your local building inspector.

5. INSTALLATIONBoards of STYROFOAM™ Brand Ultra SL Insulation are easy to handle, cut and install. Contact a local Dow representative or access the literature library at ultrawallsystem.com for more specific instructions.

6. AVAILABILITYSTYROFOAM™ Brand Ultra SL Insulation is manufactured in several locations across

extensive network. For more information, call 1-800-232-2436.

7. WARRANTYIn the United States, a 50-year thermal limited warranty is available on STYROFOAM™ Insulation products 1.5 inches and greater. For thickness less than 1.5 inches, other warranties may apply. Warranties are available as described at dbswarranties.com

8. MAINTENANCE

9. TECHNICAL SERVICESDow can provide technical information to help

™ Brand Ultra SL Insulation. Technical personnel are available to assist with any insulation project. For technical assistance, call 1-866-583-BLUE (2583)

10. FILING SYSTEMS

dowbuildingsolutions.com ultrawallsystem.com

Technical Information 1 866 583 BLUE (2583) (English) 1 800 363 6210 (French) Sales Information 1 800 232 2436 (English)

In the U.S. The Dow Chemical Company 200 Larkin Midland, MI 48674

TABLE 2: PHYSICAL PROPERTIES (U.S.) OF STYROFOAM™ BRAND ULTRA SL EXTRUDED POLYSTYRENE FOAM INSULATION

PROPERTY AND TEST METHOD VALUE

Thermal Resistance per in. ASTM C518, ft2 x h x °F/Btu, R-value,1 min. @ 75°F mean temp.

1.75" 2.125" 2.5" 3.0"

10.0 12.0 14.0 16.8

Compressive Strength,2 ASTM D1621, psi, min. 25Water Absorption, ASTM C272, % by volume, max. 0.3

Water Vapor Permeance, ASTM E96, perm, max. 1.75" 2.125" 2.5" 3.0"

1.1 0.8 0.65 0.50

Maximum Use Temperature, °F 165Coefficient of Linear Thermal Expansion, ASTM D696, in/in x °F 3.5 × 10-5

Flexural Strength, ASTM C203, psi, min. 50Flame Spread,3 ASTM E84 0Smoke Developed, ASTM E843 155

1 Values are consistent with the criteria of ASTM C578 and the FTC R-value rule (16 CFR Part 460).2 Vertical compressive strength is measured at 10 percent deformation or yield, whichever occurs first. Since STYROFOAM™ Brand Extruded

deformation. For static loads, 3:1 is suggested. For dynamic loads, 5:1 is suggested. Contact Dow for design recommendations. 3 These numerical flame-spread and smoke-developed ratings are not intended to reflect hazards presented by this or any other material under

actual fire conditions.

Notice: No freedom from infringement of any patent owned by Dow or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use and for ensuring that Customer’s workplace and disposal practices are in compliance with applicable laws and other government enactments. The products shown in this literature may not be available for sale and/or available in all geographies where Dow is represented. The claims made may not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to “Dow” or the “Company” mean the Dow legal entity selling the products to Customer unless otherwise expressly noted. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED.CAUTION: This product is combustible. Protect from high heat sources. A protective barrier or thermal barrier may be required as specified in the appropriate building code. For more information, consult MSDS, call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada.WARNING: Rigid foam insulation does not constitute a working walkable surface or qualify as a fall protection product.Dow Polyurethane Foam Insulation and Sealants CAUTION: When cured, these products are combustible and will burn if exposed to open flame or sparks from high-energy sources. Do not expose to temperatures above 240ºF (116ºC). For more information, consult MSDS, call Dow at 1-866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S. or 1-519-339-3711 in Canada.GREAT STUFF PRO™ Insulating Foam Sealant products contain isocyanate and a flammable blowing agent. Read the label and Material Safety Data Sheet carefully before use. Eliminate all sources of ignition before use. Wear long sleeves, gloves, and safety glasses or goggles. Provide adequate ventilation or wear proper respiratory protection. Contents under pressure.Building and/or construction practices unrelated to building materials could greatly affect moisture and the potential for mold formation. No material supplier including Dow can give assurance that mold will not develop in any specific system.®™Trademark of The Dow Chemical Company (“Dow”) or an affiliated company of Dow.Printed in U.S.A. Form No. 179-04132-0513 CE

Page 9: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

Stamps/Signatures

continued

Job Name

Contractor

Date

Submittal Approvals

Technical Service Hotline 1.800.225.6119 or

www.gpgypsum.comManufacturerGeorgia-Pacific Gypsum Georgia-Pacific Canada 133 Peachtree Street 2180 Meadowvale Boulevard, Suite 200 Atlanta, GA 30303 Mississauga, ON L5N 5S3

Technical Service Hotline: 1-800-225-6119

DescriptionThe DensElement™ Barrier System consists of (a) DensElement Sheathing made with a treated, water-resistant core, surfaced with fiberglass mats and a GOLD colored coating, and (b) an approved third party fluid applied flashing. DensElement Barrier System serves as a water resistant barrier and air barrier when the sheathing joints, fasteners, penetrations, openings and transitions are properly sealed with an approved third party fluid applied flashing.

DensElement Sheathing is mold resistant, and has scored a 10, the highest level of performance for mold resistance under ASTM D3273 test method.

DensElement Sheathing exhibits dimensional stability providing for a flat and rigid substrate that is noncombustible as defined and tested in accordance with ASTM E136 or CAN/ULC S114. DensElement Sheathing is generally the same strength in both directions, and it may be installed either parallel or perpendicular to wall framing members (always follow specific wall assembly installation instruc-tions as described in the DensElement Barrier System Technical Brochure).

Primary UsesThe DensElement Barrier System is specified to be used as the exterior wall sheathing, the water resistive barrier, and the air barrier as required by building code when the panel joints, fasteners, penetrations, openings and transitions are properly sealed by an approved third party fluid applied flashing per the manufacturer’s recommendations. The DensElement Barrier System can be used under a wide range of adhered, attached and rainscreen cladding systems. These include EIFS, cavity brick and claddings such as wood, vinyl, composite sidings and rainscreen claddings such as insulated metal panels.

The DensElement Barrier System eliminates the need for attached flexible membranes, fluid applied membranes or self-adhered membranes over the field of the sheathing that have typically served as the water resistive barrier and air barrier for building code compliance.

The DensElement Barrier System Sheathing is attached directly to wood or steel framing with recommended fasteners.

LimitationsThe DensElement Barrier System is not intended for immersion in water or below grade use. Cascading roof/floor water should be directed away from the exterior of the building.

Avoid conditions that will create condensation on the backside or face of DensElement Sheathing. The use of temporary forced air heaters inside an unfinished building may create volumes of water vapor which, when improperly ventilated, can condense on building materials. The use of such heaters and any resulting damage is not the responsibility of Georgia-Pacific Gypsum.

Fasteners used to attach DensElement Sheathing to framing should be flush to the panel, not countersunk.

When the DensElement Barrier System is used in slanted wall applications, do not allow water to pond or settle on it.

Georgia-Pacific Gypsum does not warrant the cladding or exterior finish system attached or adhered to the DensElement Barrier System.

Do not laminate masonry products directly to the sheathing surface of the DensElement Barrier System.

Do not use the DensElement Barrier System in roof board applications. For roof board applications, consult the DensDeck® Roof Board Technical Guide.

The DensElement Barrier System is not intended for interior or exterior ceramic tile applications. For interior tile applications in shower and bath wet areas, consult the DensShield® Tile Backer Technical Guide.

DensElement Sheathing should not be used in lieu of structural wood panels where required or used as a nailing base for mechanical fastening of cladding or other attachments.

Design details for joints, fasteners, openings, penetrations and transitions shall be installed per DensElement Barrier Systems installation instructions.

Technical DataThe DensElement Barrier System is a gypsum sheathing, water resistive barrier, and air barrier system when the joints, fasteners, penetrations, openings, and transitions are properly sealed with an approved third party fluid-applied flashing.

5/8! (15.9mm) DensElement Sheathing gypsum panel is UL designation Type DGG.

DensElement Sheathing is noncombustible as described and tested in accordance with ASTM E136, UL 723, or CAN/ULC S114.

DensElement Sheathing has a flame spread and smoke develop rating of 0/0 when tested in accordance with ASTM E84 or CAN/ULC S102.

DensElement Sheathing is manufactured to meet ASTM C1177.

DensElement Sheathing exceeds ASTM C1396 sheathing standards for humidified deflection by a factor of 10 in tests over the standard for regular gypsum sheathing.

DensElement Sheathing has a vapor permeance of >30 for 5/8! (15.9mm) tested in accordance with ASTM E96 (wet cup method).

The DensElement Barrier System was tested in accordance with applicable sections of ICC-ES Acceptance Criteria (AC) 212, Acceptance Criteria for Water-Resistive Coatings used as Water-Resistive Barriers over Exterior Sheathing, and applicable sections of AC 310, Acceptance Criteria For Water Resistive Membranes Factory Bonded To Wood Based Structural Sheathing.

The DensElement Barrier System was tested in accordance with ASTM E2178, Standard Test Method for Air Permeance of Building Materials, and ASTM E2357, Standard Test Method for Determining Air Leakage of Air Barrier Assemblies.

Page 10: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

U.S.A. Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum II LLCCanada Georgia-Pacific Canada LP SALES INFORMATION AND ORDER PLACEMENTU.S.A. West: 1-800-824-7503 Midwest: 1-800-876-4746 South Central: 1-800-231-6060 Southeast: 1-800-327-2344 Northeast: 1-800-947-4497CANADA Canada Toll Free: 1-800-387-6823 Quebec Toll Free: 1-800-361-0486TECHNICAL INFORMATION U.S.A. and Canada: 1-800-225-6119, www.gpgypsum.com

Physical Properties for DensElement SheathingProperties 5/8! (15.9 mm)

DensElement™ Sheathing

Width, nominal 4" (1219 mm) + 0 – 1/8! (3 mm)

Length, standard 8" (2438 mm), 9" (2743 mm), 10" (3048 mm), # 1/4! (6 mm)

Weight, nominal, lbs./sq. ft. (Kg/m2) 2.5 (12)

Edges Square

Bending radius 5 8" (2438 mm)

Racking strength6, lbs./ft. (dry) (N/m), Ultimate–not design value >654 (9544)

Flexural strength1,4, parallel, lbf. per Method B ≥100 (445)

Compressive strength min. 500 psi (3445 kPa)

Humidified deflection 1, 4 <1/8! (3 mm)

Permeance2, Perms (ng/Pa•s•m2) >30 (1696)

R Value3, ft2•°F•hr/BTU (m2•K/W) .67 (0.118)

Combustibility7 Noncombustible

Linear expansion with moisture change, in/in %RH (mm/mm %RH) 8 6.25 x 10-6

Surface burning characteristics per ASTM E84 or CAN/ULC S102: flame spread/smoke developed 0/0

Coefficient of thermal expansion, in/in/°F (mm/mm/°C) 9 8.5 x 10-6 (15.3 x 10-6)

1 Tested in accordance with ASTM C473 5 Double fasteners on ends as needed 2 Tested in accordance with ASTM E96 (wet cup method) 6 Tested in accordance with ASTM E72 3 Tested in accordance with ASTM C518 (heat flow meter) 7 As defined and tested in accordance with ASTM E136, UL 723, or CAN/ULC S114 4 Specified values per ASTM C1177 8 As stated by Gypsum Association GA-235 9 Tested in accordance with ASTM E228-85

Technical Service Hotline 1.800.225.6119 or

www.gpgypsum.com

TRADEMARKS DENS, DENSDECK, DENSELEMENT, DENSSHIELD, the color GOLD, GEORGIA-PACIFIC, and the GEORGIA-PACIFIC logo are trademarks owned by or licensed to Georgia-Pacific Gypsum LLC. PROSOCO, R-GUARD and FASTFLASH are registered trademarks of Prosoco, Inc.WARRANTIES, REMEDIES AND TERMS OF SALE For current warranty information for this product, please go to www.buildgp.com/warranties. All sales of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com.UPDATES AND CURRENT INFORMATION The information in this document may change without notice. Visit our website at www.gpgypsum.com for updates and current information.CAUTION For product fire, safety and use information, go to www.buildgp.com/safetyinfo or call 1-800-225-6119.FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or labeling a product as having a one-hour, two-hour, or any other fire resistance or protection rating and, therefore, as acceptable for use in certain fire rated assemblies/systems, does not mean that either a particular assembly/system incorporating the product, or any given piece of the product itself, will necessarily provide one-hour fire resistance, two-hour fire resistance, or any other specified fire resistance or protection in an actual fire. In the event of an actual fire, you should immediately take any and all actions necessary for your safety and the safety of others without regard for any fire rating of any product or assembly/system.

©2015 Georgia-Pacific Gypsum LLC. All rights reserved. 10/15. GP-TM Lit. Item #622845.

Handling and Use–WARNINGDensElement™ Sheathing contains fiberglass facings which may cause skin irritations. Dust and fibers produced during the handling and installation of the product may cause skin, eye and respiratory irritation. Avoid breathing dust and minimize contact with skin and eyes. Wear long sleeve shirts, long pants and eye protection. Always maintain adequate ventilation. Use dusk mask or NIOSH/MSHA approved respirator as appropriate in dusty or poorly ventilated areas.

Product DataSee physical properties chart below. The DensElement Barrier System holds an ICC-ES Evaluation Report for use as both a water resistive barrier and air barrier. For a copy of the Evaluation Report see www.icc-es.org.

The following is a currently approved fluid applied flashing for the DensElement Barrier System:

PROSOCO® R-Guard® FastFlash® www.prosoco.com/Content/Documents/Product/RG_FastFlash_PDS_120911_C.pdf

Page 11: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

FastFlash®

PROSOCO R-Guard® FastFlash® is a waterproofing, adhesive and detailing compound for air barrier applications that combines the best characteristics of silicone and polyurethane. This single-component, Silyl-Terminated-Polymer (STP) is easy to gun, spread-and-tool, or roller apply to produce a highly durable, seamless, elastomeric flashing membrane. Allows for same day installation of windows, doors and other wall assembly, waterproofing or air barrier components.Suitable for all climates, FastFlash® bonds directly to damp or dry surfaces and cures under a variety of weather conditions. It dramatically reduces surface preparation time by eliminating the need for reinforcing tapes at sheathing joints, inside and outside corners. It simplifies the process of producing watertight details in new or existing construction. Use FastFlash® as part of a continuous, building-wide air barrier system, or to complement conventional waterproofing or air barrier components. Use FastFlash® to adhere, transition and counter-flash R-Guard SS ThruWall or other through-wall sheet flashing.

ADVANTAGES• Available in gun-grade or roller-grade versions.• Streamlines preparation by eliminating the need

for joint reinforcing tapes.• Silane functional polymer provides superior long

term adhesion, crack bridging and weathering characteristics.

• Produces an opaque membrane when installed at the recommended 12–15 wet mils to simplify inspection and quality control.

• Bonds to most common building materials without priming.

• Single component saves time.• Produces a durable, weather-tight seal. Bonds and

cures in wet weather, on damp substrates.• Will not tear or lose effectiveness when exposed to

weather during construction.

• May be fully exposed to UV and weather for up to 12 months. If longer, contact for inspection.

• Compatible with most sealants and waterproofing or air barrier components.

• Solvent free. Isocyanate free. Phthalate free.• No shrinkage. No staining. No yellowing.• Breathable – allows damp surface to dry. • Will not support mold growth.• Service temperatures: –75 to +300°F (–59 to +149°C).• Illustration depicting the use of PROSOCO

R-Guard® products are available at www.prosoco.com by downloading the R-Guard Installation Guidelines.

Limitations• Not for use as a structural sealant. • Not for use in place of appropriate through-wall

flashing. See R-Guard SS ThruWall product literature.

• Not for use below grade or in locations designed to be continuously immersed in water.

REGULATORY COMPLIANCEVOC ComplianceR-Guard FastFlash® is compliant with the following national, state and district VOC regulations:

X US Environmental Protection Agency

X California Air Resources Board SCM Districts

X South Coast Air Quality Management District

X Maricopa County, AZ

X Northeast Ozone Transport Commission

SAFETY INFORMATIONAlways read full label and SDS for precautionary instructions before use. Use appropriate safety equipment and job site controls during application and handling. 24-Hour Emergency Information: INFOTRAC at 800-535-5053

Product Data Sheet • Page 1 of 5 • Item #70400-70405 – 051216 • ©2016 PROSOCO, Inc. • www.prosoco.com

AIR & WATER BARRIER

R•Guard

Page 12: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

Product Data SheetR-Guard FastFlash®TYPICAL TECHNICAL DATAFastFlash®

FORM viscous paste, mild odorred color

SPECIFIC GRAVITY 1.40 – 1.55pH not applicable

WT/GAL 11.75 – 12.5 lbsTOTAL SOLIDS 99%VOC CONTENT 30 g/L maximumFLASH POINT >200° F (>93° C)

FREEZE POINT not applicable

SHELF LIFE 1 year in tightly sealed, unopened container

Cured PropertiesHardness, Shore A 35–45

Tensile Strength >150 psiElongation at Break >350%

Water Vapor Transmission 21 perms ASTM E 96

Corrosive Properties Non-corrosive

Refer to the R-Guard FastFlash® Product Test Results document for a complete list of performance test results.

PREPARATIONTo ensure best results, apply to clean surfaces free of contaminants. Chemical residues, surface coatings or films may adversely affect adhesion. Pressure-treated wood and other contaminated surfaces should be cleaned with denatured alcohol or a similar solvent wipe before application.Protect people, vehicles, property, plants and all other surfaces not intended to receive FastFlash®.Remove and replace damaged sheathing. In rough openings, prime all raw gypsum board edges with R-Guard PorousPrep.Any gaps or joints greater than 1 inch should be structurally repaired or readied for an appropriate transition membrane. Ensure positive drainage at all rough openings.

Surface & Air TemperaturesSurface and ambient temperatures should be 40°F (4°C) and rising and below 110°F (43°C) during application and drying. Wind and high temperatures will accelerate drying.Hot Weather Precautions: If air or surface temperatures exceed 95°F (35°C), apply to shaded surfaces and before daytime air and surface temperatures reach their peak. Hot surfaces may be cooled with a mist of fresh water. Keep containers closed and out of direct sunlight when not in use. Cold Weather Conditions: May be applied to frost-free substrates at temperatures below 32°F (0°C). Product will not start curing and drying until temperature rises to and remains above 32°F (0°C). Low Humidity Conditions: Curing may take longer than 12 hours. Lightly misting treated surfaces with fresh water will accelerate curing. Uncured material may delay construction. Though FastFlash® may be applied to damp surfaces and tolerates rain immediately after application, do not apply to surfaces with standing water or frost. Contact PROSOCO if conditions are questionable.

EquipmentReference the gun-grade or roller-grade Application Instructions for specific recommendations of appropriate equipment.

Storage & HandlingStore in a cool, dry place. Keep container tightly closed when not dispensing. Do not open container until preparation work has been completed. Do not alter or mix with other chemicals. When stored at or below 80°F (27°C) R-Guard FastFlash® has a shelf life of 12 months after the date of manufacture. This shelf life assumes upright storage of factory-sealed containers. Do not double stack pallets. Dispose of unused product and container in accordance with local, state and federal regulations.

Product Data Sheet • Page 2 of 5 • Item #70400-70405 – 051216 • ©2016 PROSOCO, Inc. • www.prosoco.com

Page 13: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

PRODUCT TEST RESULTSR-Guard FastFlash®AAMA 714-12: VOLUNTARY SPECIFICATION FOR LIQUID-APPLIED FLASHING USED TO CREATE A WATER-RESISTIVE SEAL AROUND EXTERIOR WALL OPENINGS IN BUILDINGS

TEST METHOD CRITERIA RESULTSAdhesive Strength to Substrates ASTM C 794 ≥ 5 pli Pass

Water Penetration Around NailsModifiedASTM D 1970AAMA 711 Section 5.3

Shall pass 31 mm (1.2 in) of water Pass

Accelerated UV AgingPeel AdhesionAppearance

ASTM G 154, UVA cycle 1ASTM C 794, Visual

≥ 5 pli Pass

Elevated Temperature Exposure, Level 3=176° F for 7 days

AAMA 711ASTM C 794 ≥ 5 pli Pass

Thermal Cycling (10 cycles)Peel Adhesion

AAMA 711ASTM C 794 ≥ 5 pli Pass

Crack Bridging ASTM C 1305Water holdout of 550 millimeters for 24 hours with 1/8-inch crack after cycling per ATM C 1305 for 10 cycles.

Pass

Water Immersion AAMA 711ASTM C 794 ≥ 5 pli Pass

Water Vapor Permeability ASTM E 96 Wet CupMinimum of 10 perms at manufacturer’s recommended application thickness

Pass – 21 perms

Damp Surfaces ASTM C 794 ≥ 5 pli Pass

ICC-ES AC2121: ACCEPTANCE CRITERIA FOR WATER-RESISTIVE COATINGS USED AS WATER-RESISTIVE BARRIERS OVER EXTERIOR SHEATHING (*FASTFLASH TESTED AS PART OF AN ASSEMBLY)

*Tensile Bond ASTM C 297 Minimum 15 psi (105 kPa) Pass

*Freeze-Thaw ICC-ES AC212No cracking, checking, crazing, erosion, delamination or other deleterious effects

Pass

*Water Resistance ASTM D 2247No cracking, checking, crazing, erosion, delamination or other deleterious effects

Pass

*Water Penetration ASTM E 331No visible water penetration at sheathing joints as viewed from back of the panel.

Pass

*Weathering ICC-ES AC212AATCC2 127

No cracking of the coating; no water penetration. Pass

ABAA: AIR BARRIER ASSOCIATION OF AMERICA ACCEPTANCE CRITERIA FOR LIQUID APPLIED MEMBRANES(*FASTFLASH TESTED AS PART OF AN ASSEMBLY)

*Air Leakage of Air Barrier Assemblies ASTM E 2357 ≤ 0.2 L / s·m2 at 75 Pa

(≤ 0.04 cfm / ft2 at 1.57 psf)Pass: 0.0105 L / s·m2 at 75 Pa(0.0021 cfm / ft2 at 1.57 psf)

FIRE TESTING

Surface Burning Characteristics ASTM E 84

Criteria for ICC and NFPA Class A Building Material:Flame Spread ≤ 25Smoke Developed ≤ 450

Meets Class A Building MaterialFlame Spread: 15Smoke Developed: 10

All testing was completed by independent, accredited laboratories.Test results are applicable to both gun-grade and roller-grade versions of R-Guard FastFlash®.

NOTES:1. International Code Council Evaluation Service Acceptance Criteria 2122. American Association of Textile Chemists and Colorists

Product Test Data • Page 1 of 1 • Item #70400-70405 – 051216 • ©2016 PROSOCO, Inc. • www.prosoco.com

Page 14: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

HCI™ SYSTEM RAINSCREEN ATTACHMENT: Horizontal Continuous Insulation Should Be Simple to Design + Easy to Install

Knight's award-winning HCI™ System provides outstanding thermal perfor-mance by way of true ci (continuous insulation). As a compliment to the original CI™ System, the HCI System enables vertical cladding (and secondary rails) to be installed directly to the HCI-Girt™. This offers easy installation, broad design flexibility, and cost savings, all while still easily meeting North American energy code requirements.

The HCI System uses unique ¾” deep horizontal girts- called HCI-Girts –designed to properly disburse the façade loads over exterior rigid board insulation - with only unique thermally isolated fasteners penetrating the thermal barrier thus minimizing thermal bridging. For basic, cost-effective vertical claddings, only a single layer of HCI-Girts may be needed. For more complex cladding designs or types, choose from a wide variety of Knight Wall secondary rails for those panels requiring specific attachment points.

HCI Systems components are produced in standard and custom lengths, in either 16 or 18 gauge Zn-Al-Mg coated steel (standard silver or black PVDF coated) and also available in stainless steel.

The HCI System attachment completes the rainscreen envelope design, whether choosing metal panels, Aluminum Composite Material (ACM) panels, fiber cement, GFRC, or many more. And choose any brand of insulation that meets minimum compressive strength and code requirements, simplifying design specifications.

HORIZONTAL HCI-GIRT™ ONLY

PLAN

VIE

WSE

CTIO

N VI

EW

Page 15: Inverted Wall Opaque Wall BOD DensElement BODs/Inverted Wall_Opaque Wall BOD...Ñ Ñ:.+ ÑÄ ÑHiVcYVgY ÑIZhi ÑBZi]dYh Ñ[dg ÑLViZg Ñ Vapor Transmission of Materials Ñ Ñ9+.+

28308 N Cedar Road, Deer Park, WA 99006www.knightwallsystems.com1-855-597-9255 (KWS-WALL)509.262.0104

HCI, HCI-Girt, ThermaStop, PanelRail and RevealRail are trademarks of Knight Wall Systems, Inc. Patent 8,429,866 B2 and others pending.

¤ Energy & Atmosphere (EA) Prequisite and Credit 1¤ Materials & Resources (MR) Credits 4 and 5

ALL KNIGHT WALL SYSTEMS COMPONENTS ARE MANUFACTURED IN THE USA.

NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY KNIGHT WALL SYSTEMS. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. No freedom from any patent owned by Knight Wall Systems or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer’s use.

KNIGHT WALL CAN CONTRIBUTE TO THEFOLLOWING USGBC LEED CREDITS:

ADVANTAGES TO THE KNIGHT HCI™ SYSTEM RAINSCREEN

• Horizontal HCI-Girts can be spaced from 12” up to 36” O.C.*

• Support cladding weighing up to 9 PSF*, covering many popular cladding types

• Real labor savings – no notching or cutting of exterior rigid board insulation like with Z girts, brackets or clips

• Thermally isolated fasteners with specially designed ThermaStop™

washers come preassembled

• Highly corrosive-resistant Zn-Al-Mg ZM40 (ASTM A1046) coated steel provides a long service life vs. typical G90 Galvanized steel

• Black PVDF finish or stainless steel options available, competitively priced

• Easily installed over any type of substrate – steel studs, wood studs, CMU, concrete, even brick

• Engineering calculations provide design load compliance for each specific project

• Attach nearly any type of cladding – supplied by any manufacturer – with easy and efficient detailing and installation

• Use any manufacturers insulation meeting minimum compressive strength and other code requirements

• Cladding can be attached directly to the horizontal HCI-Girt or used with optional vertical rails (such as PanelRails or RevealRails)

• Excellent ventilation with a ¾-inch minimum continuous rainscreen cavity

• Pre-engineered and 3rd party tested for proven performance and durability

• Competitive, budget conscious assembly that meets ASHRAE 90.1 standard

• Complete, drop-in rainscreen attachment system – girts, thermally isolated fasteners, rails and engineering – one source liability for the whole system

• Limited labor and material warranty

*Maximum allowable spacing and dead load (weight of cladding) is based on the total load (dead + live) acting on the assembly and connections. Wall anchors must be specified and supplied by KWS for a written limited warranty. Knight will specify the exact anchor type, embedment depth and spacing for anchors in project specific engineering packages. ThermaStop thermal isolation washers must be used on all types of wall anchors with the HCI or CI System, no matter the substrate. Contact KWS for more information.

HCI-GIRT™ + REVEALRAIL™

PLAN

VIE

WSE

CTIO

N VI

EW


Recommended