Investigator Casualty Guide Identifying & Assessing Damage “Looking Deeper” March 2013
Transcript
Page 1: Investigator Casualty Guide

Investigator Casualty Guide

Identifying & Assessing Damage

“Looking Deeper”

March 2013

Page 2: Investigator Casualty Guide

Rupture

REPORT: Ruptured pipe, unknown type, appox 3 inches long, ¼ inch wide, Frame ___, STBD/PORT side, ___ feet above deck or from OVHD. Water on deck ___ feet ___ inches, rising 2 inches every 15 minutes

2

1

1. Rupture piping for unknown system, approximately 2 inch pipe, fresh water of unknown type. • Water color helps identify• Mist in air may have chlorine smell

2. Crack in pipe in approximately 3 inches long, smooth, at a angle.

3. Water rising in space approximately 2 inches per 15 minutes.

4. Trace pipe, look for pipe marking and valve(s)

3

Page 3: Investigator Casualty Guide

Rupture

2

1

3

1. Rupture lube oil piping for unknown system, approximately 3 inch pipe, fresh water of unknown type.

2. Crack in pipe in approximately 4 inches long, smooth, around the pipe.

3. Lube oil filling 5 gallon bucket every 5 minutes.

Page 4: Investigator Casualty Guide

Flooding

1

1. Hole below the water line, approximately 6 inches in size, smooth with no protruding metal.

2. Water rising approximately 1 foot every 15 minutes.

3. 3 feet of water in space and rising.

2

3

Page 5: Investigator Casualty Guide

Flooding

1. Hole at the water line, approximately 8 inches in size, smooth with no protruding metal.

2. Water rising approximately 1 foot every 30 minutes.

3. 2 feet of water in space and rising.

2

1

3

Page 6: Investigator Casualty Guide

Flooding

1. Flooding from unknown source, water rising at a rate of 1 foot every 15 minutes.

1

Page 7: Investigator Casualty Guide

Flooding

1. Progressive flooding from adjoining space through sprung water tight door.

2. Water rising approximately 1 foot every 15 minutes.

12

Page 8: Investigator Casualty Guide

Structural Damage

1. Debris blocking access to forward space number------.

2. Space lighting damaged, light fixtures broken and hanging, wiring damaged and hanging.

3. Ventilation blown away from over head and damaged, vent opening open into adjoining spaces, watertight integrity compromised.

4. Hole in overhead, deck plating hanging down, lagging hanging down.

5. Piping systems damaged, not ruptured.6. Some debris blocking full access to space,

estimated removal time 6 to 8 hours with 3 to 5 men.

1

2

3

4

5

6

Page 9: Investigator Casualty Guide

Structural Damage

1. Debris blocking access to space.2. Water Tight Door blown off hinges, space no

longer water tight, watertight integrity compromised to progressive flooding space to space.

3. Ventilation blown away from over head and damaged, vent opening open into adjoining spaces, watertight integrity compromised.

4. Space is demolished entire space is full of debris estimated removal time 18 to 24 hours with 3 to 5 men.

1

2

3

4

Page 10: Investigator Casualty Guide

Structural Damage

• Water Tight Door is warped and cannot be opened.

• Bulkhead is warped, with tears in metal. • Some debris is blocking passageway,

estimated removal time 6 to 8 hours with 3 to 5 men.

• Main cable way bracket is blown off bulkhead.

1 2

3

4

Page 11: Investigator Casualty Guide

Structural Damage

• Deck above space has collapsed, main structural beam is broken.

• Support station is broken loose from overhead.

• Space wiring is hanging free from wire ways.• Some debris is blocking space, estimated

removal time 6 to 8 hours with 3 to 5 men.

12

3

4

Page 12: Investigator Casualty Guide

Electrical Damage

2

1

1. 3 110 volt lighting power cables broken by shock.Circuit number______Circuit number______Circuit number______

2. Warp bulkhead behind wiring .

Page 13: Investigator Casualty Guide

Electrical Damage

1

1. 440 receptacle and power cable are burned.


Recommended