Division 15 - Mechanical
Score Acceptable Notes
15010 - Basic Mechanical Requirements A/E Spec #
WarrantyStandard Project Warranty
SubmittalSamples for finish and color verificationRecord DrawingsProduct DataShop DrawingsRecord Operating and Maintenance Manuals
Special Comments or ConditionsCertificationAll contractors shall be licensed to perform work in district area
15040 - Testing and Proof of Performance A/E Spec #
WarrantyStandard Project Warranty
SubmittalTest Reports
Special Comments or ConditionsTestingSchedule testing to allow a representative of the Owner to witness the test
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 1 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15050 - Basic Mechanical Materials and Methods A/E Spec #
WarrantyStandard Project Warranty
SubmittalShop DrawingsRecord DrawingsRecord Operating and Maintenance ManualsProduct DataSamples for finish and color verification
15060 - Basic Piping Materials and Methods A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct DataShop DrawingsRecord Operating and Maintenance ManualsSamples for finish and color verificationRecord Drawings
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 2 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15100 - Valves A/E Spec #
WarrantyStandard Project Warranty
SubmittalShop DrawingsProduct Data
Approved ManufacturersCraneHammondGrinnellMilwaukeeStockhamKeystoneVitaulic Company of AmericaNIBCONexus Valve Specialties
Special Comments or ConditionsCoordinateCoordinate valve type with installation
Domestic Water ApplicationsFor domestic water applications: 2" and smaller - ball valves; 2-1/2" and larger - butterfly valves
15130 - Refrigerant Piping A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersRefrigerant Valves and SpecialtiesAlco Controls Div., Emerson ElectricHenry Valve CompanyParker-Hannifin Corporation, Refrigeration and Air Conditioning Div.Sporlan Valve Company
Quality AssuranceQualify brazing processes and brazing operators in accordance with ASME "Boiler and Pressure Vessel Code," Section IX, "Welding and Brazing Qualifications"
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 3 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15135 - Meters and Gages A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct DataShop Drawings
Approved ManufacturersDirect Mount Dial ThermometersMarsh Instrument Co.; Unit of General SignalTrerice (H.O..) Co.Weiss Instruments, Inc.Miljoco Corporation
Glass ThermometersErnst Gage Co.Marshalltown Instruments, Inc.Trerice (H.O..) Co.Weiss Instruments, Inc.Miljoco Corporation
Pressure Gage CocksSame as for Pressure Gages
Pressure Gage Connector PlugsPeterson Equipment Co.Sisco
Pressure GagesAmetec/U.S. GaugeMarch Instrument Co.,; Unit of General SignalMarshalltown Instruments, Inc.Trerice (H.O..) Co.Weiss Instruments, Inc.Miljoco Corporation
Temperature Gage Connector PlugsPeterson Equipment Co.Sisco
Thermometers WellsSame as Thermometers
Special Comments or ConditionsCoordinateCoordinate valve type with installation
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 4 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15140 - Support and Anchors A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersHangers and SupportsB-Line Systems, Inc.Carpenter and Patterson, Inc.Corner & Lada Co., Inc.Elcen Metal Products Co.Fee & Mason Mfg. Co.; Div. Figgie InternationalITT Grinnell Corp.NIBCO (Tolco pipe hanger and supports)
Roof Equipment SupportsCustom Curb, Inc.Pate Co.Thycurb Div.; Thybar Corp.
Saddles and ShieldsElcen Metal Products Co.Pipe Shields, Inc.
Quality AssuranceComplianceProvide products which are UL-listed and FM approvedProvide products which comply with applicable codes
Special Comments or ConditionsAnchorsNo lead-based anchors
CoordinateCoordinate support type with installation
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 5 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15190 - Mechanical Identification A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersBrady (W. H.) Co.; Signmark Div.Seton Name Plate Co.Brimar Industries, Inc.
Quality AssuranceCoordinateCoordinate valve tag schedule with installation
Special Comments or ConditionsValve ChartsValve charts shall be laminated before framing
Valve Tag ChartMount valve tag chart on wall as noted in drawings
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 6 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15240 - Drainage and Vent Systems A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersJay R. Smith Mfg. Co.Josam Mfg. Co.Wade/Tyler Pipe; Subs. Of Tyler Corp.Watts Drainage ProductsZurn Industries Inc.; Hydromechanics Div.MIFAB Manufacturing, Inc.
Special Comments or ConditionsPipe ApplicationsIn return air plenums use no-hub cast-iron piping.Storm Drain Piping Above Ground, Within Building, PVC Type DWVSanitary Drain and Vent Piping Above Ground, within Building, Service weight cast-ironSanitary Drain and Vent Piping Below Ground, within Building, Service weight cast-ironStorm Srain Piping Below Ground, Within Building, Service weight cast-iron.
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 7 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15250 - Mechanical Insulation A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersArmstrong World Industries, Inc.Certainteed Corp.Knaut Fiber Glass GmbHManville Corp.Owens-Corning Fiberglass Corp.Pittsburgh Coming Corp.Rubatex Corp.
Quality AssuranceThe products of only one manufacturer shall be used for each particular insulation
Special Comments or ConditionsCoordinateCoordinate insulation type with drawings
Lined DuctworkNo lined ductwork (exception: downstream of VAV terminal unit, for sound attenuation)
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 8 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15300 - Fire Protection System A/E Spec #
WarrantyStandard Project Warranty
Special Product WarrantyEmergency Repair ServiceContractor shall provide emergency repair service for the system, within 24 hours of a request by the Owner during the Warranty Period
SubmittalOperation and Maintenance ManualsProduct DataContractor's Material & Test CertificationsShop Drawings prepared in accordance with NFPA 13Calculations stamped by a registered Engineer
ReviewsSubmittals shall be reviewed by the Owner prior to return to the Contractor
Approved ManufacturersBackflow PreventerAmmes Model 3000 SS
Fire Department Connection (where applicable)Potter-Roemer, Inc.
Fire Protection ValvesNIBCO
Fire PumpsPeerlessAurora
Swing Check ValvesReliable Kennedy Victaulic
SystemReliable Automatic Sprinkler Co., Inc.Viking SprinklerMullerKennedy ValveMilwaukeeVictaulic Company of AmericaPotter-Rowmer, Inc.NotifierPotter Electric Signal
Tamper SwitchesPotter
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 9 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Water Check ValvesReliable Kennedy
Waterflow SwitchesPotter Viking
Quality AssuranceExperienceInstaller shall have been in the Fire Protection business doing work of similar size for at least 5 years.
Manufactured in USAll fire protection components and equipment shall be manufactured in the United States.
PipeCoordinate pipe specifications with use - NO THREADED THIN WALL OR LIGHT WALL PIPE WILL BE ALLOWED
Shop DrawingsShop Drawings shall include complete hydraulic calculations, certified by a registered engineer and reviewed and stamped by the Fire Marshal, the Owner's Insurance Underwriter and other local authority have jurisdictionPlans shall include: Floor Plans, flow test data used for the design of the system, vital area protected, detailed schematic of the sprinkler risers, complete schedule of products
ULAll devices, systems and materials shall be listed by UL for its intended use
Special Comments or ConditionsCoordinateCoordinate water source with Division 15 sections and local Water Utility requirementsCoordinate design criteria with building use and plans
Sprinkler HeadsSemi-recessed Chrome, bronze uprightSprinkler Heads are to be installed in the center of ceiling tile in lay-in type ceilings
TrainingUpon completion the Fire Protection Contractor shall provide the Owner with a minimum of 8 hours training in the proper operation and testing procedures of all fire protection components provided, furnished or installed.
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 10 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15410 - Domestic Water Distribution Piping A/E Spec #
WarrantyStandard Project Warranty
SubmittalWelder's CertificationsProduct Data
Approved ManufacturersBackflow PreventersWatts Regulator Co.
Copper Joining SystemsRidgid/Viega ProPress
Dielectric UnionsPerfection Corp.Watts Regulator Co.Epco Sales, Inc.
High/Low Master Mixing ValveLawlerLeonardPowers HydroguardSymmons
Hydrants/BibbsJosam Mfg. Co.Jay R. Smith Mfg. Co.Wade/Tyler Pipe; Sub. Of Tylor Corp.Watts Drainage ProductsWoodford Mfg. Co.Zurn Industries Inc., Hydromechanics Div.
Individual Mixing ValvesLawlerLeonardPowers HydroguardSymmons
Pressure Regulating ValvesWatts Regulator Co.Bell & Gossett ITT
Shower Control Mixing Valves - Cast Brass BodyLawlerLeonardSymmonsPowers
Shower Control Mixing Valves - Concealed Mixing ValveLeonardPowers HydroguardSymmonsSpeakman Co.
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 11 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Vacuum BrakersWatts Regulator Co.Chicago Faucet Co.
Water Hammer ArrestersAmtrol, Inc.Josam Manufacturing Co.Jay R. Smith Mfg. Co.Wade/Tyler Pipe; Sub. of Tyler Corp.Watts Drainage ProductsZurn Industries Inc., Hydromechanics Div.PPP, Inc.MIFAB Manufacturing, Inc.
Quality AssuranceComplianceAll work shall comply with: ASME B 31.9 "building Services Piping", ASME "Boiler and Pressure Vessel Code," Section IX, "Welding and Brazing Qualifications" Indiana Plumbing Code
15425 - Acid Waste and Vent Piping System A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersLab-Line/Enfield Industrial CorporationR & G Sloane Mfg. Co.Orion Fittings Inc.Blucher-Josan - stainless steel pipingZurn IndustriesSpears "Labwaste" CPVC Corrosive Waste Drainage System Pipe
Quality AssuranceComplianceWork shall comply with Indiana Plumbing Code
Special Comments or ConditionsPipingIn return air plenums piping shall be PDVF piping or stainless steel piping
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 12 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15440 - Plumbing Fixtures A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersDrinking FountainFiltrine Manufacturing
Electric Water CoolersElkayHawsHalsey-TaylorOasis
Faucets - AutomaticZurn Plumbing Products GroupChicago Faucet with concealed electric solenoid boxAmerican Standard with concealed electric solenoid boxSpeakman Co. with concealed electric solenoid box
Faucets - Non-AutomaticChicago Faucet Co.T & S BrassZurn Plumbing Products GroupSpeakman
Fixture SupportsJosam Mfg. Co.Jay R. SmithWattsZurn Industries, Inc.; Hydromechanics Div.
Floor Mounted Wash BasinsBradley with deck mounted 4" center set, sensor activated hard wired faucets. Use EXD Series.Willoughby Industries with deck mounted 4" center set, sensor activated hard wired faucets. Use AquaWave lavatory system for deck mounted faucets and floor kit.Acorn Engineering Company Meridian Series
Flush Valves (Automatic)Sloan Regal Pro Optima (#110 ES-S and #111 ES-S) Automatic Hardwired Sensor Operated Flush ValveZurn (#ZEMS6000AV) Hardwired Sensor Operated Flush Valve
Flush Valves (manual operation only)Sloan Regal ProZurn Model Z6000
Food Waste DisposersIn-Sink-Erator Model Pro 17
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 13 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Lavatories, Service Sinks, Urinals, Water ClosetsAmerican Standard; U.S. Plumbing ProductsKohler Co.Crane
Mop Basins (with stainless steel wall guards)E.L.. Mustee and Sons, Inc.FiatStern WilliamsAcorn Engineering CompanySwan Corp.
Safety Shower/Eye WashBradleyEnconHawesSpeakmanGuardian Equipment
Showers (Individual) with single tempered waterSymmonsPowersLeonardAcorn Engineering Company
Showers (multihead) with single tempered waterAcornBradleyWiloughby
Stainless Steel SinksElkay Mfg. Co.Just Mfg. Co.
Water Closet SeatsBemis Mfg. Co.Beneke Corp.Olsonite Corp., Olsonite SeatsChurch
Quality AssuranceComplianceAll fixtures shall comply with the Americans With Disabilities Act (ADA)
Special Comments or ConditionsCoordinateCoordinate fixture model numbers with IPS Master Specifications
FaucetsGooseneck faucets to be used with Owner approval only
Approved ProductsFaucets - AutomaticZurn AquaSense Hardwired Sensor Operated Lavatory Faucet with cover plate and P6900-BX enclosure box
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 14 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Faucets - Non-AutomaticZurn Aquaspec
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 15 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15450 - Plumbing Pumps A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersCompact Bronze Cartridge CirculatorsArmstrong Pumps, Inc.Grundfos Pumps Corp.ITT Bell & GossettTaco, Inc.
Constant Speed Booster Pump PackageTaco, Inc.Armstrong Pumps, Inc.ITT Bell & GossettPeerless PumpsFlo-Pak
Duplex Submersible Sewage Ejector PumpsAurora PumpsHydromantic Pumps, a Marley Pump Co.Peerless PumpWeil Pump Co.Zoeller Pump Co.Tramco
Duplex Submersible Sump PumpsAurora PumpsHydromantic Pumps, a Marley Pump Co.Weil Pump Co.Zoeller Pump Co.Grundfos Pumps Corp.Armstrong Pumps, Inc.Zurn
In-Line Bronze-fitted CirculatorsAmtrol, Inc.Armstrong Pumps, Inc.ITT Bell & GossettTaco, Inc.
Quality AssuranceDomestic booster pump system shall be tested at 0%, 25%, 50%, 75% and 100% of full load capacity at scheduled suction and discharge pressureAll plumbing pumps shall be factory assembled, wired and tested, prior to shipment
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 16 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15455 - Water Softeners A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersAqua SystemsEntinCulligan
Special Comments or ConditionsSoftener shall operate on a timer control.Softeners shall be fully charged with fresh salt and mineral at Building Substantial Completion
15460 - Gas-Fired Water Heaters A/E Spec #
WarrantyStandard Project Warranty
Special Product Warranty5 year from date of project Substantial Completion
SubmittalProduct Data
Approved ManufacturersLochinvar Copper Fin II with storage tankA.O. Smith Copper Fin (85% efficiency) with storage tankRBIBradford White Corp.
Quality AssuranceHeater shall be A.G.A. approved and meet or exceed ASRAE 90-75
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 17 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15470 - Domestic Water Filtrating Equipment A/E Spec #
WarrantyStandard Project Warranty
Special Product WarrantyThe Filter System shall carry a 15 year non-prorated warranty from date of project Substantial Completion
SubmittalProduct Data
Approved ManufacturersAqua Systems (RO Central System) for drinking waterFiltrine Manufacturing Company
Special Comments or ConditionsSystem IncludesCirculating Pump and MotorFilter System
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 18 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15471 - Pool Water Treatment System A/E Spec #
WarrantyStandard Project Warranty
Special Product Warranty1 year on-site service warranty from date of project Substantial Completion shall be provided by Manufacturer's Representative2 year limited warranty from date of project Substantial Completion on parts and on pH ad HRR sensors
SubmittalProduct Data
Quality AssuranceStart-UpManufacturer's Representative shall perform initial Start-up of Water Treatment System at site.
TrainingManufacturer's Representative shall train customer on-site, to ensure proper equipment implementation.Manufacturer's Service Representative shall be trained by manufacture and receive factory authorization at a minimum schedule of every two years
Special Comments or ConditionsCoordinateCoordinate with Division 13, Special Construction, Section 15472 Controller for Pool Water Chemistry, Division 16, Electrical
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 19 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15472 - Controller for Pool Water Chemistry A/E Spec #
WarrantyStandard Project Warranty
Special Product Warranty2 year limited warranty on parts and on pH ad HRR sensors from date of project Substantial CompletionWarranties shall begin at the date of project Substantial Completion1 year on-site service warranty from date of project Substantial Completion shall be provided by Manufacturer's Representative
SubmittalProduct Data
Quality AssuranceStart-UpManufacturer's Representative shall perform initial Start-up of Water Chemistry System at site.
TrainingManufacturer's Representative shall train customer on-site, to ensure proper equipment implementation.
Special Comments or ConditionsCoordinateCoordinate with Division 13, Division 16 Electrical
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 20 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15480 - Compressed Air Systems A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersIngersoll-Rand Co.Quincy
Special Comments or ConditionsAir compressor shall provide oil free air and shall be equipped with automatic blowdown.Mount units on vibration isolators which have been anchored to substrate, in accordance with manufacturer's instructionsInstall units on 4" high reinforced concrete pad 4" larger on each side than compressor base
15490 - Natural Gas System A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct DataWelder's Certifications
Approved ManufacturersGas Line Pressure RegulatorsEquimeter (formerly Rockwell)FisherMaxatroll
ValvesJenkins Bros.Lunkenheimer Co.NIBCO, Inc.Powell Co.Stockham
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 21 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15510 - Hydronic Piping A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersVitaulic Company of AmericaGrinnell Co.Viega "Rigid Propress System" (Contract to require contractor to provide IPS with a new set of tools necessary to join each size pipe in the system.)
Special Comments or ConditionsCoordinateCoordinate with Division 15 section "Pipe Applications"
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 22 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15515 - Hydronic Specialties A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersAir SeparatorsAmtrol, IncArmstrong Pumps, Inc.Bell & Gossett ITT; Fluid Handling Div.SpirothermTaco, Inc.
Air Vents (manual and automatic)Armstrong Machine WorksBell & Gossett ITT; Fluid Handling Div.SpirothermSpirax SarcoTaco, IncNexus Valve Specialties
Automatic Flow Control ValvesAutoFlow-Flow Design Inc.Griswold ValveNexus Valve Specialties
Calibrated Balance ValvesBell & Gossett ITT; Fluid Handling Div.Taco, Inc.Armstrong Pumps, Inc.Nexus Valve Specialties
Combined Pressure-Temperature Relief ValvesBell and Gossett ITT; Fluid Handling Div.Spirax SarcoWatts Regulator Co.
Diaphragm-Type Compression TanksArmstrong Pumps, Inc.Bell & Gossett ITT; Fluid Handling Div.Taco, Inc.Wessells
Hydronic PumpsArmstrong Pumps, Inc.
Liquid Heat Transfer PumpsArmstrong Pumps, Inc.
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 23 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Pump Suction DiffusersAmtrol, IncArmstrong Pumps, Inc.Bell & Gossett ITT; Fluid Handling Div.Taco, Inc.Victaulic Company of America
Quality AssuranceComplianceAll materials shall comply with ASME standards, State and Local Codes
Special Comments or ConditionsComplianceBoiler and Pressure Vessels shall comply with ASME Section VIII, Division 1
15520 - Steam and Condensate Piping A/E Spec #
WarrantyStandard Project Warranty
SubmittalWelding testing reportsWelder's CertificationsProduct Data
Approved ManufacturersAir VentsMueller Steam SpecialtyArmstrongSpirax/Sarco
Safety Relief ValvesKunkleSpirax/Sarco
Steam TrapsHoffman Specialty ITT
StrainersArmstrongSpirax/SarcoMueller Steam Specialty
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 24 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15540 - HVAC Pumps A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersBase-Mounted End Suction PumpsBell & Gossett ITT; Fluid Handling Div.Peerless PumpTaco, Inc.Armstrong
Horizontal Split Case PumpsArmstrong
Inline Centrifugal PumpsBell & Gossett ITT; Fluid Handling Div.Peerless PumpTaco, Inc.Armstrong
Packaged Steam Condensate PumpsSkidmoreHoffman
Vertical Multi-Stage PumpsArmstrong
Vertical Sump PumpsArmstrong
Vertical Turbine PumpsArmstrong
Special Comments or ConditionsProvide electronic adjustable overloads protectionProvide phase loss protection
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 25 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15555 - Fuel-Fired Boilers A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersCondensing BoilerAercoViessmann Manufacturing Company
Gas BurnerGordon-Piatt
Scotch-Marine Firetube BoilerBurnham Corp.; Hydronics Div.Hurst Boiler Co.Kewanee Boiler Corp.Superior Boiler Works, Inc.
Wetback/Burner Package BoilerCleaver Brooks
Special Comments or ConditionsAdditional Accessories for Cast-Iron BoilerWater Level Control (McDonnal-Miller)1-1/2" side inspection openings with plugsLow water cutoff and feeder combinationBarometric damperTankless heaterFlow switch (Press. Dif.)
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 26 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15575 - Breechings, Chimneys, and Stacks A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersAll Steel, Positive Pressure, Double Wall VentsAMPCOMetal-Fab, Inc.Selkirk (Metalbestos)ScheblerStacks, Inc., Div. Of Air Management, Inc.Van Packer
Double Wall Metal VentsMetal-Fab, Inc.AMPCOGeneral Products Co., Inc.Hart & CooleyMetal-Fab, Inc.Selkirk (Metalbestos)
Special Comments or ConditionsMaintain all lightning protection on existing stacks
Condensing Boiler VentsCondensing Boiler Vents to be stainless steel
CoordinateCoordinate wall thickness with size of vent
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 27 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15670 - Split System Condensing Unit A/E Spec #
WarrantyStandard Project Warranty
Special Product Warranty5 year from manufacturer from date of project Substantial Completion
SubmittalProduct Data
Approved ManufacturersBryantCarrierLennoxTraneYork
Quality AssuranceComplianceCondensing units shall meet or exceed the minimum COP/Efficiency levels as prescribed in ASHRAE 90AUnits shall comply with ASHRAE Standards
Special Comments or ConditionsUnits shall be installed on a 4 inch thick reinforced concrete padDo not use condensate removal lift kitsCondensing coils shall be constructed of copper tubing/Aluminum fin
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 28 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15680 - Water Chillers A/E Spec #
WarrantyStandard Project Warranty
Special Product Warranty5 year from manufacturer from date of project Substantial Completion for replacement compressors
SubmittalProduct Data
Approved ManufacturersAir-Cooled Water ChillerCarrier CorporationTraneMcQuayYorkMultistack
Water-Cooled Centrifugal ChillerNot to be used in CIP projects
Quality AssuranceManufacturer shall have factory trained servicemen to supervise the evacuation, charging and start-up of the units for final operationThe unit manufacturer's serviceman shall provide and complete the manufacturer's check, test, and start forms. One copy shall be sent to the Architect/Engineer and one copy to the manufacturer's factory.Supplier shall provide all material (including refrigerant) and labor required to evacuate, charge, and accomplish the check, test, and start procedure as recommended by unit manufacturer
Special Comments or ConditionsUnits shall be installed on a reinforced concrete pad minimum of 7 1/2" thick and extending 6 " beyond unitRotary screw air-cooled chillers to be used
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 29 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15710 - Factory-Fabricated Cooling Tower A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersBaltimore Aircoil Co., Inc.Evapco, Inc.Marley (The) Cooling Tower Co.
Quality AssuranceCertificationCertify Tower wind resistance to withstand pressure indicated in any directionCertify Tower earthquake resistance against loading as indicated
Special Comments or ConditionsNot to be used in CIP projects
15720 - Evaporative Closed-Circuit Cooler A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersRecoldEVAPCOBaltimore Air CoilIMECO
Special Comments or ConditionsNot to be used in CIP projects
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 30 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15755 - Heat Exchangers A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersShell & Tube Heat ExchangersArmstrongB & G Taco
Water-To-Water Plate Heat ExchangerAlfa-LavalBaltimore Air CoilMuellerPolaris
Quality AssuranceComplianceASME Compliance: Construct heat exchanger in accordance with ASME Boiler and Pressure Vessel Code, Section VIII "Pressure Vessels", Division-1.
Manufacturer's QualificationsFirms regularly engaged in manufacture of heat exchanger, of types, materials, and size required, whose products have been in satisfactory use in similar service for not less than 5 years.
Pressure VesselsA manufacturer's data report for Pressure Vessels, Form No. U-1 as required by the provisions of the ASME Code Rules, is to be furnished for the Owner through the Engineer
Special Comments or ConditionsInstall on 4" concrete housekeeping pad as indicated, locate with required clearance for servicing.
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 31 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15775 - Electric Heating Cables A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersThermon
15780 - Rooftop Units A/E Spec #
WarrantyStandard Project Warranty
Special Product WarrantyCompressors5 year from date of project Substantial Completion
Heat Exchanger10 years from date of project Substantial Completion
SubmittalProduct Data
Approved ManufacturersCarrier CorporationTraneMcQuayYork
Quality AssuranceEnergy Efficiency RatioEqual to or greater than prescribed by ASHRAE 90.1, "Energy Efficient Design of New Buildings except Low- Rise Residential buildings."
Special Comments or ConditionsEquipment Rail Curb HeightMinimum of 24 inches
Perimeter Roof Curb HeightMinimum of 16 inches
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 32 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15830 - Terminal Units A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersBaseboard RadiationCarrier CorporationSlant/Fin Corp.Sterling RadiatorTrane (The) Co.Vulcan Radiator Co.RittlingEngA (no fiberglass lining)
Cabinet HeatersAmerican Air Filter Co.Carrier CorporationInternational Environmental Corp.McQuay Inc.Trane (The) Co.Young Radiator Co.RittlingRosemexEngA (no fiberglass lining)
CoilsAmerican Air FilterCarrier CorporationHeatcraft Coil CompanyMcQuay Inc.Trane (The) Co.York Div.USA Coil & Air (wall thickness .035 or greater)RosemexEngA
ConvectorsRittling
Face & By-PassEngA Lamiflo (no fiberglass lining)
Fan-Coil UnitsAmerican Air Filter Co.Carrier CorporationInternational Environmental Corp.McQuay Inc.Trane (The) Co.Enviro-Tec (Series HP, VF, and HL only)EngA (no fiberglass lining)
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 33 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
Unit HeaterCarrier CorporationMcQuay Inc.Modine Mfg. Co.Sterling RadiatorTrane (The) Co.RittlingRosemexEngA (no fiberglass lining)
Unit VentilatorsAmerican Air Filter Co.Carrier CorporationTrane (The) Co.McQuayEngA Unit Ventilators (no fiberglass lining)
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 34 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15835 - Electric Terminal Units A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersArchitectural Wall HeatersQ-MarkRedd-I
Baseboard RadiationErincraftQ-MarkRedd-I
Electric Duct HeatersBrasch Manufacturing Co.IndeecoAirthermDell Corporation/HetrixRedd-I
Electric Unit HeatersBrasch Manufacturing Co.ErincraftIndeecoTraneQ-MarkRedd-I
Quality AssuranceUL ComplianceProvide electrical components for terminal units which have been listed and labeled by UL
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 35 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15855 - Air Handling Units A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersAir Handling UnitsAAONAir EnterprisesBryantCarrier CorporationDesChamps Laboratories, Inc.Governair CorporationHaakonLoren Cook Company McQuayPaceTemptrolTraneYorkGreenheckVentrolEnviro-TecAmerican Energy ExchangeEngA (Heat Recovery - Heat Wheels, Heat Pipes, Plate Exchangers)
Primary Air/Heat RecoveryCarrier CorporationRenewAireSemcoTraneXetex
Special Comments or ConditionsProvide factory installed base rail to support all sections of unitsInstall floor-mounted air handling units on 4" housekeeping pads
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 36 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15870 - Exhaust Fans A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersBelt Driven Roof Exhaust FansGreenheckPennJenn IndustriesLoren Cook CompanyAcme Engineering & Manufacturing
Direct Drive Wall FansGreenheckPennJenn IndustriesLoren Cook CompanyAcme Engineering & Manufacturing
In-line Exhaust FansGreenheckPennJenn IndustriesLoren Cook CompanyAcme Engineering & Manufacturing
Special Comments or ConditionsRoof CurbsMinimum shall be 16"
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 37 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15890 - Low Pressure Ductwork A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct DataRecord DrawingsDimensioned Layout
Approved ManufacturersIndustry Standard
Special Comments or ConditionsComplianceShall comply with SMACNA Standards
15895 - Flexible Ductwork A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersIndustry Standard
Special Comments or ConditionsUse a metal 90º elbow at diffuser
ComplianceShall comply with SMACNA Standards
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 38 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15900 - Variable Frequency Drives (VFDs) A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersHoneywellABB
15902 - Sound Attenuators A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct DataShop Drawings
Approved ManufacturersRuskin
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 39 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15910 - Ductwork Accessories A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersIndustry StandardNailor IndustriesGreenheck
Special Comments or ConditionsComplianceShall comply with SMACNA Standards
ProductsVolume DampersGravity Backdraft DampersFire DampersCombination fire-Smoke DamperDuct Access DoorsTurning VanesWall Louvers
15930 - Variable Volume Terminal Units A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersCarrier CorporationEnvironmental Technology, Inc.PriceTitusTrainNailor IndustriesKrueger
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 40 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15940 - Diffusers, Registers, and Grills A/E Spec #
WarrantyStandard Project Warranty
SubmittalProduct Data
Approved ManufacturersTitusPriceKruegerAnemostatNailor Industries
Special Comments or ConditionsProductsDrum LouversExhaust RegistersPanel DiffusersReturn GrillesSupply RegistersTransfer Grilles
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 41 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15970 - Temperature Control Systems A/E Spec #
WarrantyStandard Project Warranty
SubmittalAuto-CAD compatible as-built DrawingsSystem schematics with sequencesProgramming disk for Owner useProduct Data10 copies of submittalsEquipment data cut sheetsValve and damper schedulesOperation and Maintenance Manuals
Approved ManufacturersSiemens Building Technologies - System 600 APOGEE, Installation by branch officeJohnson Controls - Metasys, Installed by branch officeAndoverAlerton TechnologiesTraneCarrier CorporationStaefa Control SystemHoneywell InternationalInvensys Automation Systems
Quality AssuranceProvide compatible systems in renovation/addition projectsProvide required testing and repair to system
Special Comments or ConditionsRelated DivisionsDivision 01000 General and Special ConditionsDivision 15000 MechanicalDivision 16000 Electrical
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score
Friday, April 08, 2005rptSpecExecutiveSummary_ByDivisionPage 42 of 43
IPS Capital Improvements ProgramStandard Building ProgramExecutive Summary
Division 15 - Mechanical
Score Acceptable Notes
15990 - Adjusting and Balancing A/E Spec #
WarrantyStandard Project Warranty
SubmittalFinal ReportReport Forms
Approved ManufacturersManufacturers/ContractorsFulton Air Balance, Inc.Johnson Controls, Inc.MSB Mechanical Systems BalancingBledsoe Environmental Systems Testing, Inc
Special Comments or ConditionsWork IncludedBalance domestic hot water return loopsAdjust individual outlets for proper air movementAdjust terminal units to deliver design air quantitiesAdjust fans to deliver, return or exhaust design air quantities to or from each space.Adjust volume dampers, diffusers, grills, and registers to proper design airflowAdjust supply, return, exhaust, and relief dampersBalance hydronic systems and pumps to design flows
1 = Meets Program Standards2 = Generally Meets Program Standards3 = Does not meet Program Standards
Score