Islesboro Microwave Design Scope Document 1/5/2016
As part of the Islesboro fiber to the home project, the town will be utilizing 3 microwave paths to give broadband to 3 outlying islands. Two of the paths will originate from the schoolhouse (44.267793°, -68.918503°) while one will originate from a contractor placed pole (44.309362°, -68.912003°) located near the center of the island. The terminus of the paths will be as follows.
• 700 Acre Island 44.258629°, -68.938003°: Contractor placed utility pole located at the end ofthe pole line near the boatyard.
• Seal Island 44.258629°, -68.938003°: Contractor placed pedestal 5’-7’• Minot Island 44.247426°, -68.933275°: Gable end of guest house.
While the town will specify the radios and antenna’s as part of a Dragonwave provided microwave design, it is expected that the contractor or its sub-contractor will perform a design walk with the town or its representatives to verify the below scope and notes and to measure out and specify quantities of such items as LMR 400, conduit, mounts and power runs. It is expected that this is a turn-key service and that items not contemplated within this scope or amended during the design walk are included in a single price given to the town of Islesboro.
Islesboro School to Minot Island
Scope – General
1.) Path microwave LINK to Dragonwave specifications 2.) Crew must be Dragonwave certified 3.) Crew is expected to preconfigure the Dragonwave radios 4.) Coordinate fiber interconnect from POP to cabinet located at the schoolhouse
Scope – School House
1.) Install microwave dish on top of existing HVAC unit located at schoolhouse utilizing existing top brackets. IMPORTANT: HVAC UNIT IS NOT TO BE PENETRATED. Only the top brackets are to be utilized to mount the microwave antenna and radio.
2.) Run conduit, power and LMR 400 from microwave radio / antenna to ground mounted cabinet. 3.) Contractor to supply and spec conduit, mounting, and all peripheral materials 4.) Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply. 5.) Hire electrician to power cabinet using school’s power.
Photo of HVAC unit located on Islesboro School House
October 21, 2015 Islesboro to Minot Island
ODU
LMR 400IDU
Power
ODU
LMR 400IDU
Power
Active Ethernet Feed from PoP
A-OPT-PLG-FIB-LX-HQ 10KM Single Mode SFP
Minot IslandIslesboro
Surge arrestor Surge arrestor
LMR 400LMR 400
IDU provides copper or fiber service
hookup. Up to Minot Island to determine ultimate routing to
the houses on island.
Scope – Minot Island
1. Contractor to mount microwave dish and radio to gable end of existing guest house (shown in picture above) and run wiring or conduit approximately 150’ to interior or outdoor cabinet as specified by the Land Lord or their representative.
2. Contractor is expected to organize access to Island. 3. Contractor to supply and spec conduit, mounting, and all peripheral materials. 4. Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply.
Islesboro School to 700 Acre Scope – General
1. Path microwave LINK to Dragonwave specifications 2. Crew must be Dragonwave certified 3. Crew is expected to preconfigure the Dragonwave radios 4. Coordinate fiber interconnect from POP to cabinet located at the schoolhouse Scope – School House
1. Install microwave dish on top of existing HVAC unit located at schoolhouse utilizing existing top brackets. IMPORTANT: HVAC UNIT IS NOT TO BE PENETRATED. Only the top brackets are to be utilized to mount the microwave antenna and radio.
2. Run conduit, power and LMR 400 from microwave radio / antenna to ground mounted cabinet. 3. Contractor to supply and spec conduit, mounting, and all peripheral materials. 4. Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply. 5. Organize electrician to power cabinet using school’s power.
Photo of HVAC unit located on Islesboro School House
Scope – 700 Acre Island
1. Contractor to supply and install a wood utility pole, mount equipment cabinet and radio to pole.2. Contractor is expected to organize access to Island.3. Contractor to supply and spec conduit, mounting, and all peripheral materials.4. Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply.5. Order power to location and set up service in the name of the town.
October 21, 2015 700 Acre Island to Islesboro School House
20.00
15.00
1
1
54.00
35.00
25.00
23.00
Boxer 5 Cabinet
Battery Cabinet
Po
wer M
eter
# 6 AWG
Ground Rod
10.00
100 amp Service to
panel 2" flex
conduit
Pole 30' Class 5
John CostaSr. OSP Engineer
Fiber “in”
Fiber “out”
October 21, 2015 700 Acre Island to Islesboro School
CR
MJ
MN
MG
T - 1
MG
T - 4
MG
T
FTA
AC
O
Ca
lix E
7-2
-
-1-
-2-
-1-
Bla
nk E
7-2
GP
ON
1G
PO
N 2
GP
ON
3G
PO
N 4
SFP
1S
FP
2S
FP
3S
FP
4S
FP
5S
FP
6S
FP
7S
FP
8X
FP
1X
FP
2S
FP
+ 1
SFP
+ 2
GP
ON
-4 r
2
FAIL
SRVC
CTRL
Boxer 5 Cabinet
Emerson DC (1 RU) Power Plant
Calix GPON 8 Port PON Line Card
tii 1x32 Spolitter 1 RU
BFO 48
F700, 1-32XD, 33-48
Fiber Drop
1 Gig Feed from Wireless
Antenna
Battery Back UpSystem
700 Acre Island
Dim RailHeater
Heat Exchange System
(Wireless “IN”)(Wireline “OUT”)
John CostaSr. OSP Engineer
Wireless G
ear
October 21, 2015 700 Acre Island to Islesboro School
Boxer 5 Cabinet
Po
wer M
eter
Power in Conduit
Power Secondary
Wireless Antenna
30-5 Pole
20'
Pole Top 24'
October 21, 2015 Islesboro to 700 Acre Island
ODU
LMR 400IDU
Power
Fiber
ODU
LMR 400IDU
Power
Active Ethernet Feed from PoP
A-OPT-PLG-FIB-LX-HQ 10KM Single Mode SFP
E7-2 A-OPT-PLG-FIB-SX-HQ 2KM Multi Mode SFP
A-OPT-PLG-FIB-SX-HQ 2KM Multi Mode SFP
700 Acre IslandIslesboro
Surge arrestor Surge arrestor
LMR 400LMR 400
W. Bay Rd to Seal Island
Scope – General
1. Path microwave LINK to Dragonwave specifications 2. Crew must be Dragonwave certified 3. Crew is expected to preconfigure the Dragonwave radios 4. Coordinate fiber interconnect from POP to cabinet located on W. Bay Rd pole
Scope – W. Bay Rd
1. Contractor to supply and install a wood utility pole, mount equipment cabinet and radio to pole. 2. Contractor to supply and spec conduit, mounting, and all peripheral materials. 3. Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply. 4. Order power to location and set up service in the name of the town.
October 13, 2015 Islesboro to Seal Island
20.00
15.00
1
1
54.00
35.00
25.00
23.00
Boxer 5 Cabinet
Battery Cabinet
Po
wer M
eter
# 6 AWG
Ground Rod
10.00
100 amp Service to
panel 2" flex
conduit
Pole 30' Class 5
John CostaSr. OSP Engineer
Fiber “in”
Fiber “out”
October 13, 2015 Islesboro to Seal Island
Boxer 5 Cabinet
Emerson DC (1 RU) Power Plant
Wireless 1RU Gear
1 Gig Feed to Wireless Antenna
Battery Back UpSystem
Islesboro -Seal Island
Dim RailHeater
Heat Exchange System
John CostaSr. OSP Engineer
1 Gig Feed from Terminal
1 gig Drop to wireless gear
Wireless G
ear
Point to Point 6581' ALM
October 13, 2015 Islesboro to Seal Island
Boxer 5 Cabinet
Po
wer M
eter
Power in Conduit
Power Secondary
1 Gig Fiber Drop
Wireless Antenna TBD
Seal Island
30-5 Pole
20' CL
Pole Top 24'
Scope – Seal Island
1. Contractor to supply and install a wooden pedestal and bury conduit approximately 150’-200’ to aLand Lord specified location.
2. Contractor to supply and spec conduit, mounting, and all peripheral materials.3. Town will spec ODU and IDU radio, microwave antenna, cabinet and contractor will supply.4. Contractor to Coordinate with Land Lord’s representative for access to island (by land lord provided
boat)
October 21, 2015 Islesboro to Seal Island
ODU
LMR 400IDU
Power
ODU
LMR 400IDU
Power
Active Ethernet Feed from PoP
A-OPT-PLG-FIB-LX-HQ 10KM Single Mode SFP
Seal IslandIslesboro
Surge arrestor Surge arrestor
LMR 400LMR 400
IDU provides copper or fiber service
hookup. Up to Seal Island to determine ultimate routing to
the houses on island.