ISTD – a sustainable choice for hot spot removal Maiken Faurbye, Max Jensen, Jesper Holm – Krüger A/S Kirsten Rügge*, Steffen Griepke Nielsen, Pia Juul Jensen, Morten Birch Larsen – NIRAS A/S Gorm Heron, Ralph Baker – TerraTherm Inc. Peder Johansen, Lone Tolstrup Karlby – Capitol Region of Denmark *Now with COWI A/S The site A PCE contamination in an impermeable clay layer has been seeping to an underlying sandy aquifer and is threatening the nearby Solhøj well field, which is one of the largest well fields in Denmark The technology Heater elements deliver the energy to the soil and heat is distributed by the thermal conductivity of the soil. Increasing temperatures drives the pollution towards gaseous form and produced steam and polluted gas is extracted through ventilation wells. Evaluation of methods Evaluation of cost-effectiveness and LCA on ISTD and alternatives long term SVE and excavation was performed. The conclusions were: • ISTD and excavation had comparable impacts on the environment. • Long-term SVE has the most adverse effect on the environment • ISTD was the most cost-effective method for hot spot removal ISTD is a robust, proven and patented technology for heating the subsurface to remediate soil and groundwater. ISTD is based on conductive heating, which means that ISTD is not limited by soil type or heterogeneity unlike techniques based on fluid conductivity. The conductive heating ensures a uniform heating with a sweep efficiency of nearly 100 % even in tight clays. In Reerslev, ISTD is being applied to remediate a hotspot of about 2-3 tons of chlorinated solvents in a low permeability clay layer. An independent evaluation process showed that hotspot remediation by ISTD was not only the most cost-effective solution but also the most sustainable solution for the site. The setup The 1300 m 2 area is remediated by use of: • 147 heaters to average 10 meters depth • 25 ventilation wells screened in the unsaturated sand below the clay • 15 horizontal ventilation drains below the vapor cap • 30 temperature monitoring wells • Light concrete vapor cap to insulate and promote pneumatic control Mass removal Existing ventilation of sand Existing P&T from secondary aquifer Solhøj well field Clay Sand Secondary aquifer Clay Sand Primary aquifer ISTD remediation area 0 10 20 30 40 50 60 1.6.09 21.6.09 11.7.09 31.7.09 20.8.09 9.9.09 29.9.09 19.10.09 8.11.09 28.11.09 Date Mass Removal Rate [kg/day] 0 20 40 60 80 100 120 Average Temperature [C] Mass removal (kg/day) Average temperature in treatment area ( o C)
Transcript

ISTD – a sustainable choice for hot spot removalMaiken Faurbye, Max Jensen, Jesper Holm – Krüger A/S

Kirsten Rügge*, Steffen Griepke Nielsen, Pia Juul Jensen, Morten Birch Larsen – NIRAS A/S

Gorm Heron, Ralph Baker – TerraTherm Inc.

Peder Johansen, Lone Tolstrup Karlby – Capitol Region of Denmark*Now with COWI A/S

The siteA PCE contamination in an impermeable clay layer has been seeping

to an underlying sandy aquifer and is threatening the nearby Solhøj well field, which is one of the largest well fields in Denmark

The technologyHeater elements deliver the energy to the soil and heat is distributed

by the thermal conductivity of the soil. Increasing temperatures drives the pollution towards gaseous form and produced steam and polluted

gas is extracted through ventilation wells.

Evaluation of methodsEvaluation of cost-effectiveness and LCA on ISTD and alternatives long term SVE and excavation was performed. The conclusions were:

• ISTD and excavation had comparable impacts on the environment.

• Long-term SVE has the most adverse effect on the environment

• ISTD was the most cost-effective method for hot spot removal

ISTD is a robust, proven and patented technology for heating the subsurface to remediate soil and groundwater. ISTD is based on conductive heating, which means that ISTD is not limited by soil type or heterogeneity unlike techniques based on fluid conductivity. The conductive heating ensures a uniform heating with a sweep efficiency of nearly 100 % even in tight clays.

In Reerslev, ISTD is being applied to remediate a hotspot of about 2-3 tons of chlorinated solvents in a low permeability clay layer. An independent evaluation process showed that hotspot remediation by ISTD was not only the most cost-effective solution but also the most sustainable solution for the site.

The setupThe 1300 m2 area is remediated by use of:

• 147 heaters to average 10 meters depth• 25 ventilation wells screened in the unsaturated sand below the clay

• 15 horizontal ventilation drains below the vapor cap• 30 temperature monitoring wells

• Light concrete vapor cap to insulate and promote pneumatic control

Mass removal

Existing ventilation of sand

Existing P&T from

secondary aquifer

Solhøj well field

Clay

SandSecondary aquifer

Clay

SandPrimary aquifer

ISTD remediation area

0

10

20

30

40

50

60

1.6.09 21.6.09 11.7.09 31.7.09 20.8.09 9.9.09 29.9.09 19.10.09 8.11.09 28.11.09

Date

Ma

ss

Re

mo

va

l R

ate

[kg

/day

]

0

20

40

60

80

100

120

Av

era

ge

Te

mp

era

ture

[C

]

Mass removal (kg/day)

Average temperature in

treatment area (oC)

Recommended