DAB PUMPS reserve the right to make modifications without prior notice ® JET GENERAL DATA Applications Self-priming centrifugal pump with excellent suction capacity even when there are air bubbles and small particles of sand in the water. Used especially for supplying water to domestic installations. Ideal for use in small-scale agriculture and gardening, limited industrial services and wherever self-priming operation is necessary. Constructional features of the pump Cast iron pump body and motor support. Motor support in die-cast aluminium for Jet 62-82-102-112-92-132. Technopolymer impeller, diffuser, Venturi tube and sand guard. Stainless steel pressure discs. Carbon/ceramic mechanical seal. Constructional features of the motor Induction motor, closed and cooled with external ventilation. Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life. Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phase version. Three-phase motors should be protected with a suitable overload protection complying with the regulations in force. Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41). Motor protection: IP 44 Terminal box protection: IP 55 Insulation class: F Standard voltage: single-phase 220-240 V/50 Hz three-phase 230-400 V/50 Hz JET 200-300 JET 62-82-102-112-92-132 JET 151-251
Transcript
Page 1: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

DAB PUMPS reserve the right to make modifications without prior notice

®

JET

GENERAL DATA

ApplicationsSelf-priming centrifugal pump with excellent suction capacity even when there are air bubbles and smallparticles of sand in the water.Used especially for supplying water to domestic installations. Ideal for use in small-scale agriculture andgardening, limited industrial services and wherever self-priming operation is necessary.

Constructional features of the pumpCast iron pump body and motor support.Motor support in die-cast aluminium for Jet 62-82-102-112-92-132.Technopolymer impeller, diffuser, Venturi tube and sand guard.Stainless steel pressure discs.Carbon/ceramic mechanical seal.

Constructional features of the motorInduction motor, closed and cooled with external ventilation.Rotor mounted on oversized greased sealed-for-life ball bearings to ensure silent running and long life.Built-in thermal and current overload protection and a capacitor permanently in circuit in the single-phaseversion.Three-phase motors should be protected with a suitable overload protection complying with theregulations in force.Manufactured according to CEI 2-3 and CEI 61-69 standards (EN 60335-2-41).Motor protection: IP 44Terminal box protection: IP 55Insulation class: FStandard voltage: single-phase 220-240 V/50 Hz

three-phase 230-400 V/50 Hz

JET 200-300

JET 62-82-102-112-92-132 JET 151-251

Page 2: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

DAB PUMPS reserve the right to make modifications without prior notice

®

* In contact with the liquid.

TECHNICAL DATA

Self priming capacity

1 4 28 7

316160

- Operating range: from 0,4 to 10,5 m3/h with head up to 62 metres

- Liquid quality requirements: clean, free from solids or abrasive substances, non viscous,non aggressive, non crystallized, chemically neutral, close tothe characteristics of water.

- Liquid temperature range: from 0°C to +35°C for domestic use (EN 60335-2-41)from 0°C to +40°C for other uses

- Maximum ambient temperature: +40°C

- Maximum operating pressure: 8 bar (800 kPa)

- Installation: fixed in a horizontal position

- Special executions on request: other voltages and/or frequencies

t (sec) Tempo di adescamento

0 10 20 30 40 50 60 70 80 90 1000 0

1

2

3

4

5

6

7

8

9

10

Hs

(m) A

ltezz

a di

asp

irazi

one

5

10

15

20

25

30

H(ft)

t (sec) Tempo di adescamento

0 10 20 30 40 50 60 70 80 90 1000 0

1

2

3

4

5

6

7

8

9

10

Hs

(m) A

ltezz

a di

asp

irazi

one

5

10

15

20

25

30

H(ft)

G 1DN 25

N.13

47

1628160

PARTS*PUMP BODYSUPPORT

IMPELLERSHAFT WITH ROTOR

MECHANICAL SEALOR GASKETNOZZLE-VENTURIDIFFUSER ASSEMBLY

MATERIALSCAST IRON 200 UNI ISO 185CAST IRON 200 UNI ISO 185DIE-CAST ALUMINIUMTECHNOPOLYMER ASTAINLESS STEEL AISI 416X12 CrS13 - UNI 6900/71CARBON/CERAMICNBR RUBBERTECHNOPOLYMER A

MODELS

JET 151; 251; 200; 300JET 62; 82; 102; 112; 92; 132

Hs

(m) S

uctio

n he

ight

t (sec) Priming time

Hs

(m) S

uctio

n he

ight

t (sec) Priming time

Page 3: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

A

A1

C

H3

H

E FI

G

B

A

A1

C

H3

H

E FI

G

B

DAB PUMPS reserve the right to make modifications without prior notice

®

A

395

A1

390

B

178

C

108

E

192

F

14

G

111

H

193

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 62 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

10,5

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,72

0,67

0,44

0,44

0,6

0,6

3,12

2,1-1,2

12,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

42

Q00

35

Q0,610

29,2

Q1,220

25,6

Q1,830

22,9

Q2,440

21,1

Q2,745

Q3,660

MODEL

JET 62 M

JET 62 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°C

Maximum ambient temperature: +40°C

JET 62

Q m3/h0 0,5 1 1,5 2 2,5 30

10

20

30

40

0

20

40

60

80

100

120

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8

10 20 30 40 50

Hm

Hft

PkPa

100

200

300

400

2 4 6 8 10 12

2 4 6 8 10

JET 62

8

6 5 4

2

Hs 9

7

3

A

395

A1

395

B

178

C

108

E

192

F

14

G

111

H

193

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 82 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

10,7

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,85

0,86

0,6

0,6

0,8

0,8

3,2

2,8-1,6

12,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

47

Q00

40

Q0,610

34

Q1,220

30

Q1,830

26,2

Q2,440

23,5

Q350

20,3

Q3,660

MODEL

JET 82 M

JET 82 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)

JET 82

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ft

PkPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JET 82

Hs 9

8

5 43 2

7 6

Page 4: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

A

A1

C

H3

H

E FI

G

B

A

A1

C

H3

H

E FI

G

B

DAB PUMPS reserve the right to make modifications without prior notice

®

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°C

Maximum ambient temperature: +40°C

JET 102

A

414

A1

409

B

178

C

108

E

197

F

14

G

111

H

203

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 102 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

12,5

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,13

1,04

0,75

0,75

1

1

5,1

3,3-1,9

16

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

53,8

Q00

47

Q0,610

41

Q1,220

36,3

Q1,830

32,4

Q2,440

28,8

Q350

25,8

Q3,660

MODEL

JET 102 M

JET 102 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40

10

20

30

40

50

0

20

40

60

80

100

120

160

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ft

PkPa

100

200

300

400

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JETCOM 102

Hs 98

7

42

65

3

A

414

A1

409

B

178

C

108

E

192

F

14

G

111

H

203

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 112 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

13,5

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,4

1,35

1

1

1,36

1,36

6,2

4,3-2,5

25

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

61

Q00

54

Q0,610

47,8

Q1,220

42,8

Q1,830

38,8

Q2,440

34,8

Q350

20

Q3,660

MODEL

JET 112 M

JET 112 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)

JET 112

Q m3/h0 0,5 1 1,5 2 2,5 3 3,5 40 0

40

80

120

160

200

0

0

0

Q l/s

Q l/min

Q IMP gpm

Q US gpm

0

0

0,2 0,4 0,6 0,8 1

10 20 30 40 50 60

Hm H

ft

PkPa

10100

20200

30300

40400

50500

60600

2 4 6 8 10 12 14 16

2 4 6 8 10 12 14

JET 112

87

42

65

3

Hs 9

Page 5: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

A

A1

C

H3

H

E FI

G

B

A

A1

C

H3

H

E FI

G

B

DAB PUMPS reserve the right to make modifications without prior notice

®

A

395

A1 B

390

C

178

E

108

F

192

G

14 111

H

193

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 92 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

11,7

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C

JET 92

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1 1,2 1,4

10 20 30 40 50 60 70 80 90

Hm

Hft

PkPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

2

75 4

3

JET 92

9

6

A

414

B

409409

A1

263

C

108

E

192

F

14

G

111

H

203

H3

144

I

9

DNA

1” G

DNM

1” G

MODEL

JET 132 470 240 240

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,022

WEIGHTKg

13,5

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,49

1,43

1

1

1,36

1,36

6,6

4,7-2,7

25

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

48

Q00

45,6

Q0,610

42,8

Q1,220

40

Q1,830

37,6

Q2,440

35

Q3

50

32,5 30 27

Q3,660

Q4,270

Q4,880

MODEL

JET 132 M

JET 132 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

0,94

0,93

0,75

0,75

1

1

4,2

3,3-1,9

14

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

36,2

Q00

33,5

Q0,610

31

Q1,220

28,4

Q1,830

26

Q2,440

24

Q3

50

21,8 19,6 17

Q3,660

Q4,270

Q4,880

MODEL

JET 92 M

JET 92 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2750 1/min)

JET 132

Q m3/h0 1 2 3 4 50 0

20

40

60

80

100

120

140

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1 1,2 1,4

10 20 30 40 50 60 70 80 90

Hm

Hft

PkPa

10100

20200

30300

40400

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs8

6

2

7

54

3

JET 132

9

Page 6: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

DAB PUMPS reserve the right to make modifications without prior notice

®

A

558

B

210

C

221

E

350

F

20

G

145

I Ø

11

H

255

H1

158

DNA

11/4”G

DNM

1” G

MODEL

JET 151 612 248 279

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,042

WEIGHTKg

31

A

632

558

210

210

221

221

350

350

20

20

145

145

11

11

255

255

158

158

B C E F G I Ø H H1 DNA

11/4”G

11/4”G

DNM

1” G

1” G

MODEL

JET 251 M

JET 251 T

657

612

248

248

279

279

0,045

0,042

35

31

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

1,6

1,6

1,1

1,1

1,5

1,5

7,2

5,2-3

31,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

61

Q00

58,2

Q0,610

56

Q1,220

53

Q1,830

50

Q2,440

46

Q350

43

Q3,660

39,5

Q4,270

36

Q4,575

MODEL

JET 151 M

JET 151 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C

JET 151

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

2,2

2,2

1,85

1,85

2,5

2,5

10

6,9-4

40

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

62

Q00

60

Q0,610

58

Q1,220

56

Q1,830

54

Q2,440

51

Q350

48,5

Q3,660

46

Q4,270

43,5

Q4,580

39

Q6

100

34,2

Q7,2120

MODEL

JET 251 M

JET 251 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2800 1/min)

JET 251

Q m3/h0 1 2 3 4 5 6 7 8 90

10

20

30

40

50

60

0

40

80

120

160

200

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,5 1 1,5 2 2,5

20 40 60 80 100 120 140

Hm

Hft

PkPa

100

200

300

400

500

600

5 10 15 20 25 30 35 405 10 15 20 25 30

6

2

75

1

3

Hs 8

4

Q m3/h0 1 2 3 4 50

10

20

30

40

50

60

0

40

80

120

160

200

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,2 0,4 0,6 0,8 1 1,2 1,4

10 20 30 40 50 60 70 80 90

Hm

Hft

PkPa

100

200

300

400

500

600

2 4 6 8 10 12 14 16 18 20 22 242 4 6 8 10 12 14 16 18 20

Hs 86

2

7

5 4

1

3

Page 7: JET - hydro-tec.grhydro-tec.gr › userfiles › files › dab-jet[1].pdf · gardening, limited industrial services and wherever self-priming operation is necessary. Constructional

DAB PUMPS reserve the right to make modifications without prior notice

®

A

521

B

214

C

151

E

282

F

20

G

160

I Ø

11

H

227

H1

175

DNA

11/2”G

DNM

11/4”G

MODEL

JET 200 612 248 279

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

0,042

WEIGHTKg

27

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

2,0

2,0

1,5

1,5

2

2

9

6,8-3,9

31,5

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HPCAPACITOR

μF Vc

Qm3/hl/min

41

46,5

38

43,5

36,5

41,8

34

39,2

31,8

37

29,5

34,2

27,2

31,8

24

28

21,3

25

Q00

Q1,525

Q2,440

Q3,660

Q4,880

Q6

100

Q7,2120

Q9

150

Q10,5175

MODEL

JET 200 M

JET 200 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)

VOLTAGE50 Hz

1x220-240 V ∼

3x230-400 V ∼

2,7

2,5

2,2

2,2

3

3

12

8,5-4,9

40

450

H(m)

P1MAXkW

InA

P2NOMINAL

kW HP

CAPACITOR

μF Vc

Qm3/hl/min

51

Q00

49

Q1,525

48

Q1,830

47

Q2,440

44,5

Q3,660

42

Q4,880

40

Q6

100

37

Q7,2120

33

Q9

150

29

Q10,5175

MODEL

JET 300 M

JET 300 T

ELECTRICAL DATA HYDRAULIC DATA (n ~ 2850 1/min)

The performance curves are based on the kinematic viscosity values = 1 mm2/s and density equal to 1000 kg/m3. Curve tolerance according to ISO 9906.

Liquid temperature range: from 0 °C to +35°CMaximum ambient temperature: +40°C

JET 200

A

595

521

214

214

151

151

282

282

20

20

160

160

11

11

235

227

175

175

B C E F G I Ø H H1 DNA

11/2”G

11/2”G

DNM

11/4”G

11/4”G

MODEL

JET 300 M

JET 300 T

657

612

248

248

279

279

0,045

0,042

31,5

27

PACKING DIMENSIONSL/A L/B H

VOLUMEm3

WEIGHTKg

JET 300

Q m3/h0 1 2 3 4 5 6 7 8 9 10 11 120

10

20

30

40

50

0

20

40

60

80

100

120

160

0

00

Q l/sQ l/min

Q IMP gpmQ US gpm

0

0

0,5 1 1,5 2 2,5 3

20 40 60 80 100 120 140 160 180 200

Hm

Hft

PkPa

100

200

300

400

5 10 15 20 25 30 35 40 45 505 10 15 20 25 30 35 40

Hs 86

3 2

75 4

1


Recommended