Date post: | 21-Dec-2015 |
Category: |
Documents |
View: | 248 times |
Download: | 0 times |
Jianchun (JC) Wang, 08/21/99
RICH Electronics and DAQ
Chip Carrier
Short Cable
Transition Board
Long Cable
Data Board
Crate
J.C.WangSyracuse University
CLEO Meeting, 08/21/99
Jianchun (JC) Wang, 08/21/99
OutlineRICH Hardware:• VA-RICH chip carrier• Data board• Cables, transition board, and cabling• Crate and other electronic cards (CPU card, TIM, Pulser board,
SBUS controller & Power monitor board, gcal board)
Software:• DAQ• Monitor code• Calibration code
Jianchun (JC) Wang, 08/21/99
R.Mountain, CLEO M tg, 20 Aug 1999
C harged Pa rticle Track
C athode Pad Photon Dete ctor
LiF R adiator M edium
Ch eren k o v P h o to n s
To tal ly In tern ally - Reflected P h o to n s
C ere nkov R ing
Expa ns ion Zone
Jianchun (JC) Wang, 08/21/99
RICH Data Board
Main Features:• Differential Signal ADC
• Bias voltage and current control
• Parameter monitor (T, I, V)
• Coherent noise subtraction, and data sparsification
What we concern:• Precision of charge measurement
• Short term fluctuation (noise performance)
• Long term stability
Jianchun (JC) Wang, 08/21/99
Status of RICH Data Board
• 120 + boards are ready
• Noise performace meet goal (Incoherent noise < 3 ADC counts)
• High temperature oscillation of power supply solved
• Analog board and digital board are mounted together
Jianchun (JC) Wang, 08/21/99
RICH DAQ
• Version 9902 used for cylinder test before the insertion– Crate information not in event tag– Beamtest data format and event tag
• Version 9904 will be used for coming test– Gcal used, so wirepulse calibration is possible– Final event tag & close to final data format event tag– DB problem existing ( with more than two crates)
• Final version 99xx– DB bug fixed– Finish date is uncertain
Jianchun (JC) Wang, 08/21/99
RICH Monitor• Data board parameters (Bayar)
– Power voltage, bias current and voltage, temperature
– Code ready to get information, need graphic display and alarm
• Raw data quality (Jian)– Number of hits, number of channel used in CM noise calculation, coherent noise,
pulser height, etc
– Code ready to get partial informations, more need to be done
• Pass1 data quality (JC, or Tomasz)– Number of hits, pulse height, number of pads per track, number of cluster per track,
Cherenkov angle distribution, etc
– Not start yet
• HV (Peter Thies)
• Gas (Alex & Stephan)– TEA temperature, flow rate, N2 transparency, etc
– Running
Jianchun (JC) Wang, 08/21/99
RICH Calibration
• Existing modes:– Normal mode (pedestal, noise)– Flash, Flash with hold– Single channel mode– Wirepulse mode
• Parameters store in data base:– Pedestal, noise, dead channel, gain parameters– Unify the online and offline data base ?
Jianchun (JC) Wang, 08/21/99
Summary
• Hardware:– Chip carrier, CPU, and most electronic cards
are ready, some need further work– Cabling nearly finish, test of part and whole
cylinder will come soon
• Software:– Need a lot of work
Jianchun (JC) Wang, 08/21/99
RICH Readout Hardware
• VA-RICH chip carrier
• Data board
• Cables, transition board, and cabling
• Crate and other electronic cards:
CPU card, TIM, Pulser board, SBUS controller & Power monitor board, gcal board