+ All Categories
Home > Documents > JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99...

JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99...

Date post: 08-Oct-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
12
JM AEROFOIL Fan Code: 160JM/40/8/6/... 1600 mm 720 rev/min 6 Blades 50 Hz BS 5750 Pt 1 EN 29001 ISO 9001 04/03/99 SK11858 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance only Performance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances. 0 10 20 30 40 50 0 50 100 150 200 250 300 350 400 450 0 50000 100000 150000 0 20000 40000 60000 80000 100000 0 10 20 30 40 0.0 0.5 1.0 1.5 0 10 20 30 40 50 0 2 4 6 8 10 12 14 16 18 8º 16º 24º 32º 8º 16º 24º 32º 97 99 104 99 99 102 101 101 104 100 102 105 ISO 5801 Type C+2D V Sound Data BS848 Part 2 1985: Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratory specifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Use upper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area. Inlet Levels Outlet Levels Pitch Angle Octave Band Centre Frequency (Hz) Pitch Angle Octave Band Centre Frequency (Hz) Pitch Angle 63 125 250 500 1k 2k 4k 8k Pitch Angle 63 125 250 500 1k 2k 4k 8k 8 –19 –16 –12 –13 –5 –11 –4 –6 –9 –5 –14 –8 –18 –11 –26 –23 8 –16 –13 –9 –11 –4 –10 –4 –5 –8 –4 –13 –6 –17 –10 –24 –22 16 –15 –10 –13 –9 –10 –9 –4 –7 –6 –8 –10 –8 –13 –10 –17 –15 16 –13 –7 –12 –7 –9 –9 –4 –7 –6 –7 –10 –8 –12 –9 –16 –14 24 – 32 24 – 32 24 – 32 24 – 32 –13 –9 –7 –7 –6 –8 –6 –7 –10 –8 –15 –11 –17 –12 –19 –13 –10 –6 –6 –6 –6 –7 –5 –6 –9 –8 –13 –10 –15 –10 –18 –12 If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.
Transcript
Page 1: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/8/6/...1600 mm 720 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11858

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 500

50

100

150

200

250

300

350

400

4500 50000 100000 150000

0 20000 40000 60000 80000 100000

0

10

20

30

40

0.0

0.5

1.0

1.5

0 10 20 30 40 5002468

1012141618

16º

24º

32º

8º16º

24º

32º

97

99

104

99

99

102

101

101

104

100

102

105

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–19–16

–12–13

–5–11

–4–6

–9–5

–14–8

–18–11

–26–23

8–16–13

–9–11

–4–10

–4–5

–8–4

–13–6

–17–10

–24–22

16–15–10

–13–9

–10–9

–4–7

–6–8

–10–8

–13–10

–17–15

16–13

–7–12

–7–9–9

–4–7

–6–7

–10–8

–12–9

–16–14

24 – 3224 – 32 24 – 3224 – 32–13

–9–7–7

–6–8

–6–7

–10–8

–15–11

–17–12

–19–13

–10–6

–6–6

–6–7

–5–6

–9–8

–13–10

–15–10

–18–12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 2: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/8/9/...1600 mm 720 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11859

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

100

200

300

400

500

600

7000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50 600

5

10

15

20

25

30

16º

24º

32º

8º16º

24º

32º

99

98

105

99

98

99

102

102

102

100

103

106

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–21–19

–14–14

–5–12

–3–5

–9–6

–15–7

–19–11

–28–24

8–18–16

–12–10

–5–11

–2–3

–8–4

–14–6

–19–11

–27–23

16–19–13

–14–7

–6–10

–3–9

–8–8

–14–7

–18–8

–22–17

16–16

–9–12

–4–6–9

–3–9

–7–7

–13–6

–16–8

–21–15

24 – 36 24 – 36–10

–8–10

–8–9–8

–7–8

–7–8

–9–10

–11–11

–12–13

–6–4

–7–4

–7–6

–6–7

–6–7

–8–9

–10–9

–11–12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 3: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/50/8/12/...1600 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11861

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

100

200

300

400

500

600

7000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50 6005

101520253035

16º

24º

32º

8º16º

24º

32º

101

99

109

101

100

100

102

102

102

103

104

108

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–21–21

–11–14

–6–11

–3–4

–11–6

–15–8

–20–12

–29–26

8–19–19

–9–12

–6–11

–2–4

–10–4

–13–5

–18–10

–27–24

16–18–14

–14–8

–9–12

–4–8

–6–7

–11–6

–15–8

–22–18

16–15–11

–11–6

–8–11

–4–9

–5–7

–10–4

–13–5

–21–16

24 – 36 24 – 36–11–8

–10–7

–8–9

–6–8

–7–8

–11–10

–13–12

–15–15

–8–4

–7–3

–6–7

–5–7

–6–7

–11–9

–12–11

–14–14

Page 4: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/50/8/12/...1600 mm 720 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11861

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 600

100

200

300

400

500

600

7000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000

0

10

20

30

40

50

60

70

0.0

0.5

1.0

1.5

2.0

2.5

0 10 20 30 40 50 6005

101520253035

16º

24º

32º

8º16º

24º

32º

101

99

109

101

100

100

102

102

102

103

104

108

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–21–21

–11–14

–6–11

–3–4

–11–6

–15–8

–20–12

–29–26

8–19–19

–9–12

–6–11

–2–4

–10–4

–13–5

–18–10

–27–24

16–18–14

–14–8

–9–12

–4–8

–6–7

–11–6

–15–8

–22–18

16–15–11

–11–6

–8–11

–4–9

–5–7

–10–4

–13–5

–21–16

24 – 36 24 – 36–11–8

–10–7

–8–9

–6–8

–7–8

–11–10

–13–12

–15–15

–8–4

–7–3

–6–7

–5–7

–6–7

–11–9

–12–11

–14–14

Page 5: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/6/6/...1600 mm 960 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11862

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

100

200

300

400

500

600

700

8000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

10

20

30

40

50

60

70

80

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0 10 20 30 40 50 60 7005

10152025303540

16º

24º

32º

8º16º

24º

32º

103

105

111

106

106

109

108

108

110

106

108

111

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–21–19

–15–13

–8–13

–4–8

–7–4

–13–7

–16–9

–23–19

8–17–15

–12–11

–7–13

–2–7

–6–4

–11–6

–15–7

–22–18

16–15–12

–14–8

–12–10

–5–8

–5–7

–9–8

–13–9

–16–14

16–13

–9–12

–7–12

–9–5–8

–5–7

–8–8

–10–8

–15–13

24 – 32 24 – 32–14–10

–9–7

–7–9

–5–8

–9–8

–13–10

–17–13

–18–13

–11–6

–7–6

–6–7

–4–6

–8–8

–12–9

–15–10

–17–11

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 6: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/6/9/...1600 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11863

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

200

400

600

800

1000

12000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

20

40

60

80

100

120

0

1

2

3

4

0 10 20 30 40 50 60 70 800

10203040506070

16º

24º

32º

8º16º

24º

32º

106

105

112

106

106

106

109

109

109

107

109

113

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–24–21

–17–13

–10–15

–3–8

–7–4

–14–7

–17–9

–26–19

8–21–18

–14–10

–9–14

–1–6

–5–3

–12–6

–17–8

–25–18

16–19–13

–17–6

–11–11

–3–11

–7–9

–12–8

–17–7

–21–15

16–15

–9–14

–3–10–10

–3–10

–5–8

–11–8

–14–7

–20–13

24 – 36 24 – 36–8–8

–10–7

–10–9

–8–9

–7–9

–8–9

–12–12

–12–13

–4–3

–6–4

–8–7

–7–8

–7–7

–7–9

–10–10

–11–12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 7: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/50/6/9/...1600 mm 960 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11864

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 700

200

400

600

800

1000

12000 50000 100000 150000 200000

0 20000 40000 60000 80000 100000 120000 140000

0

20

40

60

80

100

120

0

1

2

3

4

0 10 20 30 40 50 60 700

10203040506070

16º

24º

32º

8º16º

24º

32º

105

105

113

106

106

108

110

108

109

108

109

112

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–20–20

–13–16

–8–14

–4–8

–7–4

–12–7

–14–7

–25–21

8–17–16

–10–13

–7–13

–3–7

–5–4

–11–6

–13–6

–23–19

16–18–11

–13–11

–7–10

–4–9

–8–8

–13–7

–18–7

–23–17

16–14

–8–11–7

–5–8

–3–7

–6–7

–12–5

–16–6

–21–16

24 – 36 24 – 36–11–8

–11–9

–8–8

–5–8

–7–9

–11–10

–15–12

–16–14

–8–5

–8–6

–6–6

–4–6

–6–8

–9–8

–13–10

–15–12

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 8: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/50/6/12/...1600 mm 960 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11865

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 10 20 30 40 50 60 70 800

200

400

600

800

1000

1200

14000 50000 100000 150000 200000 250000

0 20000 40000 60000 80000 100000 120000 140000 160000

0

20

40

60

80

100

120

140

0

1

2

3

4

5

0 10 20 30 40 50 60 70 800

1020304050607080

16º

24º

32º

8º16º

24º

32º

107

106

115

107

106

106

109

108

109

110

111

115

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–23–22

–14–17

–7–13

–3–6

–8–5

–15–8

–17–9

–27–23

8–21–19

–12–16

–6–11

–2–6

–7–3

–12–5

–15–6

–25–21

16–17–13

–17–14

–12–10

–4–10

–5–7

–9–7

–13–6

–21–16

16–14

–9–15–12

–10–7

–4–10

–4–7

–9–6

–10–3

–19–13

24 – 36 24 – 36–9–7

–12–10

–9–8

–7–8

–7–9

–10–9

–13–11

–15–15

–6–3

–9–6

–6–6

–5–7

–6–8

–9–9

–12–10

–14–14

If it is intended to run this fan in reverse for other than emergency operation, please refer to Woods Air Movement.

Page 9: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/12/6/...1600 mm 480 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11867

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 350

50

100

150

2000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000

0

5

10

15

20

0.0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0 5 10 15 20 25 30 350

1

2

3

4

5

88

90

96

90

16º

24º

32º

8º16º

24º

32º

90

93

92

92

95

91

93

96

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–14–13

–8–13

–3–8

–6–4

–13–7

–16–9

–23–19

–29–27

8–12–10

–6–11

–2–7

–6–3

–12–7

–14–7

–22–18

–28–26

16–14

–8–12

–9–5–8

–5–7

–9–8

–12–9

–15–13

–19–17

16–12

–5–11–8

–4–7

–5–7

–8–8

–12–8

–13–12

–18–16

24 – 32 24 – 32–9–7

–6–8

–5–7

–9–8

–13–9

–17–12

–18–12

–21–14

–7–4

–6–7

–5–6

–7–6

–12–9

–15–11

–16–10

–20–13

Page 10: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/12/9/...1600 mm 480 rev/min 9 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11868

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

3000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 25 30 35 40012345678

16º

24º

32º

8º16º

24º

32º

91

89

96

90

90

90

94

93

93

92

94

98

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–13

–10–14

–2–7

–6–4

–14–7

–17–8

–26–19

–32–28

8–14–10

–7–12

–2–7

–5–3

–13–6

–15–7

–26–19

–32–27

16–16

–6–10–11

–3–10

–7–9

–12–8

–16–7

–21–15

–25–20

16–13

–2–8–9

–2–9

–7–9

–11–7

–15–6

–19–15

–24–18

24 – 36 24 – 36–9–6

–10–8

–7–8

–7–8

–8–9

–11–11

–11–12

–14–14

–5–2

–7–5

–5–6

–6–7

–7–7

–10–10

–10–10

–13–13

Page 11: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/50/12/12/...1600 mm 480 rev/min 12 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11870

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

300

3500 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

35

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

0 5 10 15 20 25 30 35 400123456789

16º

24º

32º

8º16º

24º

32º

92

90

100

92

90

90

93

92

93

94

96

100

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–14–17

–7–13

–3–6

–8–4

–15–8

–16–9

–27–22

–33–31

8–12–15

–6–11

–2–7

–7–4

–14–6

–14–7

–25–20

–32–29

16–17–14

–12–9

–4–10

–5–7

–9–7

–12–5

–20–16

–26–21

16–14–10

–10–6

–3–9

–5–7

–8–6

–12–4

–18–13

–24–18

24 – 36 24 – 36–11–9

–8–7

–6–7

–7–7

–9–8

–13–10

–14–14

–17–16

–8–5

–4–3

–4–6

–6–6

–8–7

–12–10

–13–12

–16–15

Page 12: JM AEROFOIL - venttech.co.nzventtech.co.nz/assets/Fan/160JM.pdf · ISO 9001 SK11858 04/03/99 Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance

JM AEROFOILFan Code: 160JM/40/10/6/...1600 mm 575 rev/min 6 Blades 50 HzBS 5750 Pt 1

EN 29001ISO 9001

04/03/99SK11871

Performance Data ISO 5801: The AMCA Certified Ratings Seal applies to air performance onlyPerformance shown is for installations type C – Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances.

0 5 10 15 20 25 30 35 400

50

100

150

200

250

3000 20000 40000 60000 80000 100000 120000

0 10000 20000 30000 40000 50000 60000 70000 80000

0

5

10

15

20

25

30

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0 5 10 15 20 25 30 35 400123456789

16º

24º

32º

8º16º

24º

32º

92

94

100

94

94

97

96

96

98

95

97

100

ISO 5801

Type C+2DV

Sound Data BS848 Part 2 1985:Single figures on performance curves are overall inlet sound power levels, derived from measurements taken in Woods laboratoryspecifically under ducted conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level.Useupper corrections when operating point is above shaded area, or lower corrections when operating point is below shaded area.

Inlet Levels Outlet Levels

PitchAngle

Octave Band Centre Frequency (Hz) PitchAngle

Octave Band Centre Frequency (Hz)PitchAngle 63 125 250 500 1k 2k 4k 8k

PitchAngle 63 125 250 500 1k 2k 4k 8k

8–17–15

–9–13

–4–9

–6–4

–11–6

–15–8

–21–15

–27–25

8–14–12

–7–11

–3–8

–5–4

–10–6

–14–7

–20–14

–26–24

16–15–10

–12–9

–6–9

–4–7

–8–8

–12–8

–14–12

–18–16

16–12

–7–11–7

–6–8

–4–7

–7–7

–11–8

–12–11

–17–15

24 – 32 24 – 32–11–8

–6–7

–5–8

–8–8

–11–9

–16–12

–18–12

–20–14

–9–6

–6–6

–5–6

–7–6

–11–9

–15–11

–16–10

–19–12


Recommended