+ All Categories
Home > Documents > JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section...

JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section...

Date post: 03-Oct-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
16
® JMPVAZ - JMPVD Electronic remote voltage control unit Technical Catalogue January 2018 web edition
Transcript
Page 1: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

®

JMPVAZ - JMPVD Electronic remote voltage control unit

Technical CatalogueJanuary

2018

web edition

Page 2: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

2E/JMPVAZ-JMPVD/01/2018

JMPVAZ joystick is a strong and compact device, whose ergonomic shape

is handily organised.

The person present system switch and many other remote control func-

tions can be implemented and operated conveniently. It is developed to

meet mobile machinery market requirements, where it is increasingly im-

portant to handle the power transmission supply with integrated remote

control.

JMPVAZ is simple to fit and replace and is made up of a standard module

with two proportional axes and a hand grip that can house several combi-

nations of other proportional axes (up to 4) and ON/OFF outputs.

This joystick allows all the electronic features of ramp generator function,

electronic flow adjustement, and dead band compensation (only for pro-

portional axes).

ORDERING CODE JMPVAZM800 Y Z W

JMPVAZ Joystick

ON/OFF push buttons

0 1 2 3 4 5 6

No. of switches in the hand grip side

Additional ON/OFFpush buttons

0none

TTop

Dpersonpresentsystem

Bboth (T+D)

Z axis position 0

noneH

horizontalL

leftR

rightB

both (L+R)

®

Page 3: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

3E/JMPVAZ-JMPVD/01/2018

ON/OFF push buttons (Y)and Z axis position (Z)

Additional ON/OFF push buttons (W)

JMPVAZ Joystick

JMPVAZM80000. JMPVAZM8000B. JMPVAZM8001R. JMPVAZM80020.

JMPVAZM8002H. JMPVAZM8000R. JMPVAZM8000H. JMPVAZM8001L.

JMPVAZM8002R. JMPVAZM80030. JMPVAZM8000L. JMPVAZM80010.

JMPVAZM8001H. JMPVAZM8002L. JMPVAZM80040. JMPVAZM8003R.

JMPVAZM8003L. JMPVAZM80050. JMPVAZM80060.

TtopD

personpresentsystem

®

Page 4: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

4E/JMPVAZ-JMPVD/01/2018

Dimensions and electrical details

1 = Negative supply voltage2 = Negative signal3 = X axis output +4 = US+ ( Safety system output )5 = US- ( Safety system output )6 = Y axis output +7 = Positive signal control8 = Positive supply voltage9 = “A” port, directional output (max.

load 30 mA), X axis10 = “B” port, directional output (max.

load 30 mA), X axis

11 = Signal control, X Axis12 = ( free )13 = Signal control, Y Axis14 = “B” port, directional output (max.

load 30 mA), Y axis15 = “A” port, directional output (max.

load 30 mA), Y axis16 = Negative supply voltage17 = Negative signal18 = Z axis output +19 = ( free )20 = US+ on-off output (max. load 30 mA)

21 = US- on-off output (max. load 30 mA)22 = Positive signal control23 = Positive supply voltage24 = “A” port, directional output (max.

load 30 mA), Z axis25 = “B” port, directional output (max.

load 30 mA), Z axis26 = Signal control, Z Axis27 = ( free )28 = ( free )29 = ( free )30 = ( free )

JMPVAZM8002RD- 2 ON/OFF push buttons in

hand grip side- Z axis in right position - person present system push

button

JMPVAZ Joystick®

Page 5: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

5E/JMPVAZ-JMPVD/01/2018

= signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²)

JMPVAZM8002RD

JMPVAZ Joystick

In order to verify if the hook-up is correct, please proceed as follows:

1) By touching with the multimeter the pin no. 1 and the pin “ground” (), the tension voltage supply (UDC) must be read.

2) By touching with the multimeter the pin no. 2 and the pin “ground” ( ), half of the tension voltage supply (50% UDC) must be read, with joystick in neutral position and if the hookup keeps the module (MHPOD/MHPED) switched on.

3) With multimeter in the same position as per point 2, by moving the joystick the signal control must be 25% of UDC on one side and 75% UDC on the other side

The methods of control and the param-eters as per points 1), 2), 3) are the same for all kinds of our joysticks.

Electrical system

®

Page 6: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

6E/JMPVAZ-JMPVD/01/2018

1 = Negative supply voltage2 = Negative signal3 = X axis output +4 = US+ ( Safety output )5 = US- ( Safety output )6 = Y axis output +7 = Positive signal control8 = Positive supply voltage9 = “A” port, directional output (max.

load 30 mA), X axis10 = “B” port, directional output (max.

load 30 mA), X axis

11 = Signal control, X Axis12 = ( free )13 = Signal control, Y Axis14 = “B” port, directional output (max.

load 30 mA), Y axis15 = “A” port, directional output (max.

load 30 mA), Y axis16 = Negative supply voltage17 = Negative signal18 = Z axis output +19 = ( free )20 = ( free )

21 = ( free )22 = Positive signal control23 = Positive supply voltage24 = “A” port, directional output (max.

load 30 mA), Z axis25 = “B” port, directional output (max.

load 30 mA), Z axis26 = Signal control, Z Axis27 = ( free )28 = ( free )29 = ( free )30 = ( free )

Dimensions and electrical details

JMPVAZM8000LD- NO push buttons in hand grip

side- Z axis in left position - person present system push

button

JMPVAZ Joystick®

Page 7: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

7E/JMPVAZ-JMPVD/01/2018

= signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²)

Electrical system

JMPVAZM8002RD JMPVAZM8000LD

JMPVAZ Joystick®

Page 8: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

8E/JMPVAZ-JMPVD/01/2018

JMPVD Joystick

JMPVD joystick is a strong and compact device, whose ergonomic shape

is handily organised.

The person present system switch and many other remote control func-

tions can be implemented and operated conveniently. It is developed to

meet mobile machinery market requirements, where it is increasingly im-

portant to handle the power transmission supply with integrated remote

control.

JMPVD is simple to fit and replace and is made up of a standard module

with two proportional axes and a hand grip that can house several combi-

nations of other ON/OFF outputs.

This joystick allows all the electronic features of ramp generator function,

electronic flow adjustement, and dead band compensation (only for pro-

portional axes).

®

Page 9: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

9E/JMPVAZ-JMPVD/01/2018

K handle (no switch)

H handle (rocker switch)

L handle (person present system swith)

JMPVD0M800530

JMPVD0M800531

JMPVD0M800533

JMPVD Joystick®

Page 10: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

10E/JMPVAZ-JMPVD/01/2018

“K” Handle (no switch)JMPVD0M800530

Dimensions and electrical details

1 = Negative supply voltage2 = Negative signal3 = X axis signal control4 = ( free )5 = ( free )6 = Y axis output +7 = Positive signal control8 = Positive supply voltage9 = “A” port, directional ou-

tput (max. load 30 mA), X axis

10 = “B” port, directional ou-tput (max. load 30 mA), X axis

11 = Signal control, X Axis12 = ( free )13 = Signal control, Y Axis14 = “B” port, directional ou-

tput (max. load 30 mA), Y axis

15 = “A” port, directional ou-tput (max. load 30 mA), Y axis

JMPVD Joystick®

Page 11: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

11E/JMPVAZ-JMPVD/01/2018

Electrical system

= signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²)

“K” Handle (no switch)JMPVD0M800530

JMPVD Joystick®

Page 12: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

12E/JMPVAZ-JMPVD/01/2018

Dimensions and electrical details

1 = Negative supply voltage2 = Negative signal3 = X axis signal control4 = Common terminal

switch on/off/on5 = Switch on (max. load =

50 mA)6 = Y axis signal control7 = Positive signal control8 = Positive supply voltage9 = “A” port, directional ou-

tput (max. load 30 mA), X axis

10 = “B” port, directional ou-tput (max. load 30 mA), X axis

11 = Signal control, X Axis12 = Switch on (max. load =

50 mA)13 = Signal control, Y Axis14 = “B” port, directional ou-

tput (max. load 30 mA), Y axis

15 = “A” port, directional ou-tput (max. load 30 mA), Y axis

“H” Handle (rocker switch)JMPVD0M800531

JMPVD Joystick®

Page 13: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

13E/JMPVAZ-JMPVD/01/2018

Electrical system

= signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²)

“H” Handle (rocker switch)JMPVD0M800531

JMPVD Joystick®

Page 14: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

14E/JMPVAZ-JMPVD/01/2018

Dimensions and electrical details

1 = Negative supply voltage2 = Negative signal3 = Output X axis (+)4 = Common terminal switch5 = Switch on (max. load = 50

mA)6 = Output Y axis (+)7 = Positive signal8 = Positive supply voltage9 = “A” port, directional output

(max. load 30 mA), X axis10 = “B” port, directional output

(max. load 30 mA), X axis11 = Signal control, X Axis12 = ( free )13 = Signal control, Y Axis14 = “B” port, directional output

(max. load 30 mA), Y axis15 = “A” port, directional output

(max. load 30 mA), Y axis

“L” Handle (person present system switch)JMPVD0M800533

JMPVD Joystick®

Page 15: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

15E/JMPVAZ-JMPVD/01/2018

Electrical system

= signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²)

“L” Handle (person present system switch)JMPVD0M800533

JMPVD Joystick®

Page 16: JMPVAZ - JMPVD Electronic remote voltage control unit ... · = signal leads (min. cross-section 0.50 mm²) = supply leads (min. cross-section 0.75 mm²) JMPVAZM8002RD JMPVAZ Joystick

®

Rev. 01

Dana Motion Systems Italia S.r.l.Fluid Power Division

Sede operativa: Via Giulio Natta 1, 42124 Reggio Emilia - Italy Tel: +39.0522.270711 - Fax: +39.0522.505856

Sede legale: Via Luciano Brevini 1/A, 42124 Reggio Emilia - Italy Tel: +39.0522.9281 - Fax: +39.0522.928300

www.dana.com/brevini - [email protected]


Recommended