Building joints A to Z
Transcript
Page 1: Joint Batiment - Anglais 6P

Building joints

A to

Z

We have over 20 years of experience in designing, manufacturing andmarketing a complete range of standard and seismic joints:joint covers, expansion and control joints, fire stop systems, etc.

All the professionals recognise our expertise: architects, consultants,general businesses and subcontractors.

EXPANSION JOINTSFor horizontal and vertical applications.Our extensive range caters to all types of projects:public or private, industrial, commercial and service projects.We are constantly developing new products and have just expanded our range including a special joint for use with flexible floor coverings, and for seismic or non-seismic joint gaps up to 200 mm.

JOINT COVERS• Clip affixed aluminium or PVC joint covers. All RAL colours available including natural wood, gold, silver, bronze, brass, and any other special colours.• Extruded, drilled, countersunk joint covers up to 320 mm wide.• Adhesive or folded joint covers in stainless steel, galvanized steel, mill finish or anodised aluminium, or powder coated with a thickness of 5/10 to 30/10.

FIRE STOP SYSTEMSApplications: expansion joints, heads of walls, floor nosings, curtain walls.• VEDAFEU C fire stop backer rods which have been officially tested and validated for joint gaps from 10 to 200 mm. • VEDAFEU N fire stop blankets which have been officially tested and validated for joint gaps up to 840 mm. Movement +/- 50%.

USES Schools, hospitals, shopping centres, industrial buildings and housing, airports, railway stations, leisure centres, car parks, etc.

GUARANTEES : Regular tests and inspections carried out by official laboratories(CSTB, Efectis, TÜV) guarantee the highest standards (Classification Reports, patents, designs).

The GV2 Veda France team is at your disposal for any information or advice you may need.

GV2 VEDA FRANCECS 63052

95972 Roissy CDG CedexFrance

Telephone : +33 (0) 1 48 61 70 80Fax : +33 (0) 1 48 61 70 81E-mail : [email protected] : www.vedafrance.com

Page 2: Joint Batiment - Anglais 6P

WHAT IS AN EXPANSION JOINT ? THE RIGHT PROFILE

An expansion joint is an empty space, free of any material between two parts of a structure. It goes all the way up the structure allowing each part to move freely without interference.

The size of an expansion joint depends on what deformations are possible in the construction. Whether standard or seismic, an expansion joint should allow horizontal, vertical and shear movements.

CAUSES OF MOVEMENTS

• Concrete removal

• Expansion and contraction of the concrete structure (temperature

changes)

• Settlement of the structure

• Movements generated by the environment (wind, vibration)

• Earthquakes

HOW TO CHOOSE AN EXPANSION JOINT ?

1. Location (floor, wall, façade, ceiling)

2. Initial gap

3. Expected movement

4. Expected load/passage

5. Waterproofing requirementn

6. Flush or inserted installation

7. Type of finish

8. Fire resistance

9. Cost

Choosing the right profile for performance and aesthetics is essential for durability.REFERENCES WORLDWIDE ...

Structure :Negara Bruneï DarussalamEsplanade at Yayasan Sultan Hassanal Bolkiah.

Veda France profile number :Floor expansion joint Series 446-b

BEFORE AFTER

IMPLEMENTATION

We only use approved contractors to ensure that our material is correctly installed.

We are available for technical assistance, support and advice.

A COMPLETE RANGE OF RELIABLE SOLUTIONS

JOINT COVERSTo protect and cover expansion joints (flat and angle) on façades, floors, walls and ceilings.

VEDAFEU® C BACKER RODSOfficially tested and validated for joint gaps from 10 to 200 mm.

CAR PARK FLOOR JOINTSWatertight joints for car parks with steel side plates and flexible inserts.

CONTROL JOINTSSealed application. In metal and flexible insert or co-extruded PVC.

NOSINGNon-slip grooved aluminium or aluminium with non-slip insert.

FLEXIBLE PROFILES Flexible profiles adjusted for fast and economic closure of expansion joints.

FAÇADE JOINTSTechnical joints to close façade, wall and roof joints.

ROOF JOINTSTechnical joints to close roof expansion joints.

WATERSTOPSJoints in concrete reinforcement, expansion, partitioning, etc.

STRUCTURAL WORK RANGEPlastic parts and profiles for the calibration of vertical and horizontal reinforcement.

CONTROL JOINTSAdhesive application. In metal and flexible insert or co-extruded PVC.

VEDAFEU® N BLANKETSOfficially tested and validated for joint gaps up to 840 mm with +/- 50% movement.

STANDARD FLOOR JOINTSTechnical joints with aluminium corner caps and flexible inserts.

JOINTS FOR FLEXIBLE FLOORSSpecial joints for use in flexible floor coverings.

Horizontal joint

Vertical joint

Page 3: Joint Batiment - Anglais 6P

WHAT IS AN EXPANSION JOINT ? THE RIGHT PROFILE

An expansion joint is an empty space, free of any material between two parts of a structure. It goes all the way up the structure allowing each part to move freely without interference.

The size of an expansion joint depends on what deformations are possible in the construction. Whether standard or seismic, an expansion joint should allow horizontal, vertical and shear movements.

CAUSES OF MOVEMENTS

• Concrete removal

• Expansion and contraction of the concrete structure (temperature

changes)

• Settlement of the structure

• Movements generated by the environment (wind, vibration)

• Earthquakes

HOW TO CHOOSE AN EXPANSION JOINT ?

1. Location (floor, wall, façade, ceiling)

2. Initial gap

3. Expected movement

4. Expected load/passage

5. Waterproofing requirementn

6. Flush or inserted installation

7. Type of finish

8. Fire resistance

9. Cost

Choosing the right profile for performance and aesthetics is essential for durability.REFERENCES WORLDWIDE ...

Structure :Negara Bruneï DarussalamEsplanade at Yayasan Sultan Hassanal Bolkiah.

Veda France profile number :Floor expansion joint Series 446-b

BEFORE AFTER

IMPLEMENTATION

We only use approved contractors to ensure that our material is correctly installed.

We are available for technical assistance, support and advice.

A COMPLETE RANGE OF RELIABLE SOLUTIONS

JOINT COVERSTo protect and cover expansion joints (flat and angle) on façades, floors, walls and ceilings.

VEDAFEU® C BACKER RODSOfficially tested and validated for joint gaps from 10 to 200 mm.

CAR PARK FLOOR JOINTSWatertight joints for car parks with steel side plates and flexible inserts.

CONTROL JOINTSSealed application. In metal and flexible insert or co-extruded PVC.

NOSINGNon-slip grooved aluminium or aluminium with non-slip insert.

FLEXIBLE PROFILES Flexible profiles adjusted for fast and economic closure of expansion joints.

FAÇADE JOINTSTechnical joints to close façade, wall and roof joints.

ROOF JOINTSTechnical joints to close roof expansion joints.

WATERSTOPSJoints in concrete reinforcement, expansion, partitioning, etc.

STRUCTURAL WORK RANGEPlastic parts and profiles for the calibration of vertical and horizontal reinforcement.

CONTROL JOINTSAdhesive application. In metal and flexible insert or co-extruded PVC.

VEDAFEU® N BLANKETSOfficially tested and validated for joint gaps up to 840 mm with +/- 50% movement.

STANDARD FLOOR JOINTSTechnical joints with aluminium corner caps and flexible inserts.

JOINTS FOR FLEXIBLE FLOORSSpecial joints for use in flexible floor coverings.

Horizontal joint

Vertical joint

Page 4: Joint Batiment - Anglais 6P

WHAT IS AN EXPANSION JOINT ? THE RIGHT PROFILE

An expansion joint is an empty space, free of any material between two parts of a structure. It goes all the way up the structure allowing each part to move freely without interference.

The size of an expansion joint depends on what deformations are possible in the construction. Whether standard or seismic, an expansion joint should allow horizontal, vertical and shear movements.

CAUSES OF MOVEMENTS

• Concrete removal

• Expansion and contraction of the concrete structure (temperature

changes)

• Settlement of the structure

• Movements generated by the environment (wind, vibration)

• Earthquakes

HOW TO CHOOSE AN EXPANSION JOINT ?

1. Location (floor, wall, façade, ceiling)

2. Initial gap

3. Expected movement

4. Expected load/passage

5. Waterproofing requirementn

6. Flush or inserted installation

7. Type of finish

8. Fire resistance

9. Cost

Choosing the right profile for performance and aesthetics is essential for durability.REFERENCES WORLDWIDE ...

Structure :Negara Bruneï DarussalamEsplanade at Yayasan Sultan Hassanal Bolkiah.

Veda France profile number :Floor expansion joint Series 446-b

BEFORE AFTER

IMPLEMENTATION

We only use approved contractors to ensure that our material is correctly installed.

We are available for technical assistance, support and advice.

A COMPLETE RANGE OF RELIABLE SOLUTIONS

JOINT COVERSTo protect and cover expansion joints (flat and angle) on façades, floors, walls and ceilings.

VEDAFEU® C BACKER RODSOfficially tested and validated for joint gaps from 10 to 200 mm.

CAR PARK FLOOR JOINTSWatertight joints for car parks with steel side plates and flexible inserts.

CONTROL JOINTSSealed application. In metal and flexible insert or co-extruded PVC.

NOSINGNon-slip grooved aluminium or aluminium with non-slip insert.

FLEXIBLE PROFILES Flexible profiles adjusted for fast and economic closure of expansion joints.

FAÇADE JOINTSTechnical joints to close façade, wall and roof joints.

ROOF JOINTSTechnical joints to close roof expansion joints.

WATERSTOPSJoints in concrete reinforcement, expansion, partitioning, etc.

STRUCTURAL WORK RANGEPlastic parts and profiles for the calibration of vertical and horizontal reinforcement.

CONTROL JOINTSAdhesive application. In metal and flexible insert or co-extruded PVC.

VEDAFEU® N BLANKETSOfficially tested and validated for joint gaps up to 840 mm with +/- 50% movement.

STANDARD FLOOR JOINTSTechnical joints with aluminium corner caps and flexible inserts.

JOINTS FOR FLEXIBLE FLOORSSpecial joints for use in flexible floor coverings.

Horizontal joint

Vertical joint

Page 5: Joint Batiment - Anglais 6P

Building joints

A to

Z

We have over 20 years of experience in designing, manufacturing andmarketing a complete range of standard and seismic joints:joint covers, expansion and control joints, fire stop systems, etc.

All the professionals recognise our expertise: architects, consultants,general businesses and subcontractors.

EXPANSION JOINTSFor horizontal and vertical applications.Our extensive range caters to all types of projects:public or private, industrial, commercial and service projects.We are constantly developing new products and have just expanded our range including a special joint for use with flexible floor coverings, and for seismic or non-seismic joint gaps up to 200 mm.

JOINT COVERS• Clip affixed aluminium or PVC joint covers. All RAL colours available including natural wood, gold, silver, bronze, brass, and any other special colours.• Extruded, drilled, countersunk joint covers up to 320 mm wide.• Adhesive or folded joint covers in stainless steel, galvanized steel, mill finish or anodised aluminium, or powder coated with a thickness of 5/10 to 30/10.

FIRE STOP SYSTEMSApplications: expansion joints, heads of walls, floor nosings, curtain walls.• VEDAFEU C fire stop backer rods which have been officially tested and validated for joint gaps from 10 to 200 mm. • VEDAFEU N fire stop blankets which have been officially tested and validated for joint gaps up to 840 mm. Movement +/- 50%.

USES Schools, hospitals, shopping centres, industrial buildings and housing, airports, railway stations, leisure centres, car parks, etc.

GUARANTEES : Regular tests and inspections carried out by official laboratories(CSTB, Efectis, TÜV) guarantee the highest standards (Classification Reports, patents, designs).

The GV2 Veda France team is at your disposal for any information or advice you may need.

GV2 VEDA FRANCECS 63052

95972 Roissy CDG CedexFrance

Telephone : +33 (0) 1 48 61 70 80Fax : +33 (0) 1 48 61 70 81E-mail : [email protected] : www.vedafrance.com

Page 6: Joint Batiment - Anglais 6P

Building joints

A to

Z

We have over 20 years of experience in designing, manufacturing andmarketing a complete range of standard and seismic joints:joint covers, expansion and control joints, fire stop systems, etc.

All the professionals recognise our expertise: architects, consultants,general businesses and subcontractors.

EXPANSION JOINTSFor horizontal and vertical applications.Our extensive range caters to all types of projects:public or private, industrial, commercial and service projects.We are constantly developing new products and have just expanded our range including a special joint for use with flexible floor coverings, and for seismic or non-seismic joint gaps up to 200 mm.

JOINT COVERS• Clip affixed aluminium or PVC joint covers. All RAL colours available including natural wood, gold, silver, bronze, brass, and any other special colours.• Extruded, drilled, countersunk joint covers up to 320 mm wide.• Adhesive or folded joint covers in stainless steel, galvanized steel, mill finish or anodised aluminium, or powder coated with a thickness of 5/10 to 30/10.

FIRE STOP SYSTEMSApplications: expansion joints, heads of walls, floor nosings, curtain walls.• VEDAFEU C fire stop backer rods which have been officially tested and validated for joint gaps from 10 to 200 mm. • VEDAFEU N fire stop blankets which have been officially tested and validated for joint gaps up to 840 mm. Movement +/- 50%.

USES Schools, hospitals, shopping centres, industrial buildings and housing, airports, railway stations, leisure centres, car parks, etc.

GUARANTEES : Regular tests and inspections carried out by official laboratories(CSTB, Efectis, TÜV) guarantee the highest standards (Classification Reports, patents, designs).

The GV2 Veda France team is at your disposal for any information or advice you may need.

GV2 VEDA FRANCECS 63052

95972 Roissy CDG CedexFrance

Telephone : +33 (0) 1 48 61 70 80Fax : +33 (0) 1 48 61 70 81E-mail : [email protected] : www.vedafrance.com