Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH. 7 September 2001, Malmo Ken-ichi Kimura Professor, Advanced Research Institute for Science and Engineering, Waseda University, Tokyo Fax:+81-3-3209-8316 E-mail: [email protected]. - PowerPoint PPT Presentation
Popular Tags:
37
Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Me eting JAPANESE BUILDING EN ERGY RESEACH 7 September 2001, Malmo Ken-ichi Kimura Professor, Advanced Research Institu te for Science and Engineering, Waseda University, Tokyo Fax:+81-3-3209-8316 E-mail: [email protected]
Transcript
Page 1: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENER

GY RESEACH7 September 2001, Malmo

Ken-ichi KimuraProfessor, Advanced Research Institute fo

r Science and Engineering,

Waseda University, Tokyo

Fax:+81-3-3209-8316

E-mail: [email protected]

Page 2: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Climate of Japan

• Japanese archipelago ranges from cold to subtropical regions.

• In central mild areas, heating season: November-April in residential buildings January-March in office buildings.

Page 3: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Energy Use Trends in JapanIndustrial Sector Residential and

Commercial SectorTransportation Sector

0

2000

4000

6000

8000

10000

12000

14000

16000

73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98

[PJ]

- S. Ando

Page 4: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Residential Energy Breakdowns by District

Page 5: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

1/3 of CO2 are related to buildings in Japan

Page 6: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Operation Energy of an Office Building

Page 7: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Energy Conservation and

Natural Energy Utilisationare different.

Page 8: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Definition of Energy Conservation

• Minimisation of Energy Use while maintaining desire of people.

• Energy may be used as much as they want unless they think it wasteful.

• Energy conservation is not enough to meet the target of Kyoto protocol.

Page 9: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Natural Energy Utilisation

• Solar thermal• Photovoltaics• Wind power• Geothermal power• Ambient energy

Page 10: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Solar Hot Water Heaters

• Solar water heaters are installed in about 1/10 of total households.

• Forced circulation type of domestic solar water heating system can be seen in houses.

Page 11: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Solar Hot Water System

• Swimming pools

• Elderly people’s homes

• Hospitals

• Schools

• Apartments

Page 12: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Passive Solar Space Heating

• Traditionally common in residences.

• Insulation and air-tightness are prerequisites for passive solar heating

Page 13: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Passive Cooling in Residences

• Natural ventilation and sun shading are pre-requisites.

• Nocturnal ventilation• Cool tube• Earth contact floor• Roof garden for

evaporative cooling• Nocturnal radiation

Page 14: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Improvement in Efficiency of Household Appliances

• Refrigerators• Lighting bulbs

(Compact lamps are not common in Japan.)

• Room Air-Conditioners

Colour TV

Air Conditioner

Refrigerator

Year

Page 15: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Energy Conservation in Buildings

• Energy Conscious Designs

• Energy Reduction in Lighting

• Energy Reduction in HVAC

• Energy Reduction in Office Machines

Page 16: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Energy Conservation in HVAC

• Heat Recovery System

• Variable Air/Water Volume System

• Free Cooling/ Night Purge

• Sun Shading

• Air Flow Windows

• Controls for Efficient Operation

• Set Point Temperature and Humidity

Page 17: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Thermal Comfort and Energy Conservation

• 1 degree of change in set point temperature makes 10% of energy saving in both heating and cooling.

• Slight increase in air movement substantially reduces cooling load.

Page 18: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Indoor Air Quality and Energy Conservation

• Displacement ventilation

• Occupied zone air conditioning

• Minimum allowable rate of ventilation

Page 19: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Occupied Zone Air Conditioning in Large Spaces

0

500

1000

1500

Hea

t L

oad

[W

/㎡・

day]

MeasurementOccupied zone Air-ConditionOverall Air-Conditioning

8/18 8/208/19 8/23 8/24 2/16 2/18 2/19 2/21 2/22

Page 20: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Direct Sunlight Introduction

Page 21: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Photovoltaics Integration in Architecture

Page 22: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Residential PhotovoltaicSystem Installation

NumberCapacity

[MW]

PowerGeneration

[106kWh]

PowerRequired

[106kWh]

PVContribution

[%]

60,000 219 230 897,600 0.026

1,370,000 5,000 5,256 1,056,000 0.500

Page 23: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Residential Photovolaic Cost

2000 Aug. 2002 Forcast

PV module cost 56.0 (63%) 41.4 (64%)Ancilary equipment cost 20.9 (24%) 12.2 (19%)Installation cost 11.9 (13%) 11.2 (17%)Total system cost 88.8(100%) 64.8(100%)

Page 24: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

PV Panels Backed with Air Collector

Kyocera House

Page 25: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Natural Energy Utilisation in Vernacular Architecture

Page 26: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Massive House in Kawagoe

Page 27: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Modern Use of Vernacular Technologies

Page 28: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Earth Covered Building

Page 29: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Solar Architecture

• Heavy insulation and air-tightness

• natural ventilation and sun shading

• passive solar heating

• solar domestic hot water system

• PV for appliances

Page 30: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

IEA Task 13 AdvancedJapanese House-WISH House

Page 31: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Kimura Solar House - 1972

• Movable collector panels

• Semi-basement with greenhouse

• Floor heating by heat pump

• Solar domestic hot water

• PV roof (2001)

Page 32: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Sagara Solar House - 1979

• Hybrid solar• Outside

insulation• No auxiliary for

space heating• 5028 kWh/a for

total household

Page 33: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

TEPCO Solar House - 1988• Earth contact floor• Rock bed storage coupled

with air collector and heat pump

• Sun space• Heat pump for hot water

from space cooling with off-peak electricity

• Phase change material floor• 7800kWh/a for total

household

Page 34: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Solar Chimney and PV Panels

• School building of Kitakyushu University, Faculty of Environmental Engineering

Page 35: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Carbon Emission from Buildings by Structural Types

-100

-50

0

50

100

150

200

WOODEN STEELREINFORCEDCONCRETE

REINFORCEDCONCRETE

STEEL AVERAGE

CA

RB

ON

EM

ISS

ION

PR

OM

BU

ILD

ING

SF

OR

FLO

OR

AR

EA

[kg

/m2]

WOOD(-)

OTHER MATERIALS

TRANSPORTATION

STEEL

CERAMICS

CONCRETE

WOOD(+)

Global Environment Committee,AIJ 1992

Page 36: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Conclusion-1

• Energy   conservation has a largest potential in reducing energy requirements in building sector.

• Different types of natural energy utilisation must be sought for different conditions.

Page 37: Joint FP5 ENERGIE Info-day and EnerBuild RTD Project Meeting JAPANESE BUILDING ENERGY RESEACH

Conclusion-2

• A slight discomfort must be accepted for reducing energy use and warming gas emission.