Input Power: 40W / 60W / 80W
Efcacy: 109 Lm/W Series Average
CCT: 3000K / 4000K / 5000K
CRI: >70
Input Voltage: 100-277VAC Standard
Dimming: 10VDC Dimming Standard
Control: Dusk-to-Dawn Photocell Standard
Construction: Acrylic Housing and Cast Aluminum Base
Surge Protection: 10kV Standard
EPA: 1.5 sq.ft.
Ingress Protection: IP65 Standard
Lifetime Based on TM21: L70 @ ≥ 150,000 hrs / L80 @ ≥ 120,000 hrs /L90 @ ≥ 61,000 hrs
Performance Summary
JPT ACORN POST TOP SERIES
Product Description
The JPT Post Top Series provides the efciency and zero lifetime maintenance of the latest LED technology while maintaining traditional architectural designs.
The JPT series is ideal for large scale municipal and institutional projects as well as smaller commercial and residential applications.
This series features dusk to dawn photo sensor and 0-10VDC continuous dimming as standard features to allow for stand alone operation or the addition of various control modules now and in the future.
The JPT series is designed to operate at -40F to +130F with 10kV surge protection for use in all climate conditions.
Product Dimensions and Styles
12.00"
14.0
0"
16.5”
39
.8”
39
.8”
18.1” 16.5”
37
.3”
HA-R HB-FC HC-NC HC-NC-NF
Housing Styles
Certications
WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Page 1 of 3
Information contained herein is subject to change without notice. Values are nominal.
Revised 11/2020
Warranty: 10 Year Limited
SPECIFICATION SUBMITTAL DETAIL
Project Name/Type: Date:
Catalog/Part #:
SLIPFITTER MOUNT
Accepts up to 2-7/8" O.D.Round Tenon or Pole
Round Pole Tenon Reducers*available for 3", 4", & 5" O.D. Poles
*Special RequestContact Manufacturer
TYPE V Light Distribution(See next page for Photometry Details)
WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Page 2 of 3
Information contained herein is subject to change without notice. Values are nominal.
Revised 11/2020
Performance and Electrical Data Table
JPT ACORN POST TOP LIGHT SERIESORDERING INFORMATION / Example: JPT-AC-40W-HA-R-BK
Product Series CCT Input Voltage Controls & Dimming Other Options Housing Style Housing Colors
JPT-AC-40W
JPT-AC-60W
JPT-AC-80W
30K (3000K)
40K (4000K)
50K (5000K)
HA-R (With ribs and band)HB-FC (Full cover on top only)
HC-NC (No cover)HC-NC-NF (No Cover / No Finial)
Blank
(100-277VAC)
Standard
Blank
(Button Style Dusk-to-Dawn
Photocel l 10VDC Dim)
Standard
Blank (Surge Protector 10KV)
Standard
BK(Black Finish)
Standard
Product Number JPT-AC-40W JPT-AC-60W JPT-AC-80W
Maximum Dimensions
Nominal watts 40W 60W 80W
Nominal Efficacy @ 3000K 104.35 Lm/W 101.98 Lm/W 104.19 Lm/W
Nominal Efficacy @ 4000K 107.22 Lm/W 104.94 Lm/W 106.35 Lm/W
Nominal Efficacy @ 5000K 107.49 Lm/W 105.19 Lm/W 105.01 Lm/W
Lumen Output @ 3000K 4277.7 6250.4 8270.5
Lumen Output @ 4000K 4307.9 6438.0 8388.8
Lumen Output @ 5000K 4382.5 6413.2 8268.3
Input Voltage 100-277VAC 100-277VAC 100-277VAC
CRI >75 >75 >75
THD @ 120VAC 0.90
Standard Control Spec.
Construction
Beam Angle/Field Angle
Effective Projective Area (EPA)
Lifetime Based on TM21
Ambient Working Temperature
Certifications ETL Listed
Limited Warranty
IES Type 5VS / 158° / 180°
-40°F ~ to +130°F
10 Yrs
ETL Listed
1.5 sq.ft.
18.1" Width x 39.75" Height / 3." ID Post Top Receiver
1-10VDC Dimming / Dusk-to-Dawn Photocell
Die Cast Aluminum Alloy Base / Epoxy Powder Coat / Acrylic Housing
L70 @ ≥ 150,000 hrs / L80 @ ≥ 120,000 hrs / L90 @ ≥ 61,000 hrs
CRAL(Custom RAL Color)
Special Order
JPT SERIESACORN POST TOP LUMINAIRE
Photometry Detail
JPT - 40W Type 5Spacing Criteria (0-180) 2.92Spacing Criteria (90-270) 1.80Spacting Criteria (Diagonal) 2.66
1. Vertical Plane at Max. Values2. Horizontal Cone at Max. Values
JPT-40W Type 5 Illumination PlotMounting Height = 10ft. above grade
JPT - 60W Type 5Spacing Criteria (0-180) 2.92Spacing Criteria (90-270) 1.80Spacting Criteria (Diagonal) 2.66
1. Vertical Plane at Max. Values2. Horizontal Cone at Max. Values
JPT-60W Type 5 Illumination PlotMounting Height = 10ft. above grade
JPT - 80W Type 5Spacing Criteria (0-180) 2.94Spacing Criteria (90-270) 1.80Spacting Criteria (Diagonal) 2.68
1. Vertical Plane at Max. Values2. Horizontal Cone at Max. Values
JPT-80W Type 5 Illumination PlotMounting Height = 10ft. above grade
WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Page 3 of 3
Information contained herein is subject to change without notice. Values are nominal.
Revised 11/2020
Page 1Page 2Page 3
Project Name/Type: Catalog/Part #: Date: Housing Colors: Housing Style: Other Options: Controls & Dimming: Input Voltage: CCT: Product Series: