1
PIER 17 - MINOR MODIFICATIONJULY 19, 2016
SOUTH STREET SEAPORT
2
THE SITE
3
SOUTH STREET SEAPORT // THE SITE ( OCTOBER 2012)
4
SOUTH STREET SEAPORT // THE SITE (MARCH 2016)
5
SOUTH STREET SEAPORT // THE SITE (JULY 2016)
6
SOUTH STREET SEAPORT // PIER 17 - 2015 APPROVAL
7
PIER 17
LINK BUILDING
TIN BUILDING HEADHOUSE
SOUTH STREET SEAPORT // PIER 17 - 2013 APPROVAL
8
SOUTH STREET SEAPORT // PIER 17 DEMOLITION
PIER 17
TIN BUILDING ELIMINATE HEADHOUSE
DEMO OF LINK BUILDING
9
SOUTH STREET SEAPORT // PIER 17 - 2015 LPC APPROVAL
WEST FACADE
TIN BUILDINGACCESS DRIVE AND
HARDSCAPE ALTERATIONS
10
RECONSTRUCTED TIN BUILDING
ACCESS DRIVE AND HARDSCAPE
ALTERATIONS
SOUTH STREET SEAPORT // PIER 17 - NEW PROPOSAL
11
DESIGNTIN BUILDING
18
1940: The Tin Building’s historic context in the wide expression of South Street. Today, the building is isolated from its historical connections to the street by the FDR (ca. 1954). (NYC MA)
SOUTH STREET SEAPORT // HISTORY
1940: The Tin Building’s historic context in the wide expression of South Street. Today, the building is isolated from its historical connections to the street by the FDR (ca. 1954). (NYC MA)
2012: Flood waters on South Street from Superstorm Sandy.
12
SOUTH STREET SEAPORT // TIN BUILDING // REASON FOR MOVE
SOUTH STREET SEAPORT // TIN BUILDING // REASON FOR MOVE // 2013 APPROVED SITE CONDITION
ACCESS DRIVE
FEMA 100 YEARFLOODPLAIN(NAVD88 EL 12)
SOUTH ST.ELEVATION4.29’
APPROVEDPIER 17
APPROVEDPIER
17 HEAD HOUSE
FDR DRIVE TIN BUILDING
REFRIGERATION SHED
13
PIER 17
REMOVED HEAD HOUSE
PIER 17 WEST FACADE
SOUTH STREET SEAPORT // TIN BUILDING // REASON TO RELOCATE THE BUILDING
TIN BUILDING RAISED 1’ ABOVE FEMA 100 YEAR FLOOD PLAIN
FEMA 100 YEARFLOODPLAIN(NAVD88 EL 12)
SOUTH ST.ELEVATION4.29’
FDR DRIVE TIN BUILDING
ACCESS DRIVE
REFRIGERATION SHED
14
PIER 17
SOUTH STREET SEAPORT // TIN BUILDING // REASON FOR MOVE // PROPOSED SITE CONDITION
15’-11” - 16’-11”
TIN BUILDING(RAISED 1’ ABOVE FEMA 100 YEAR FLOOD PLAIN)
(WE NEED TO MITIGATE AN 8.8’ HEIGHT CHANGE IN 107’FROM SOUTH STREET TO TIN BUILDING)
RAISED 6.07’ (FROM THE EXISTING TIN
BUILDING ELEVATION)
SETBACK 32’-00” (FROM THE EXISTING TIN
BUILDING LOCATION)
107’
FEMA 100 YEARFLOODPLAIN(NAVD88 EL 12)
SOUTH ST.ELEVATION4.29’
ACCESS DRIVE
FDR DRIVE
15
1" = 50'-0"DSK-012
1BUILD HEADHOUSE + RENOVATE LINK BUILDING
APPROVED SITE PLAN
PIER 16 PIER 16
FULTONPLAZA
LINKBUILDING
FULTONPLAZA
NORTHPORCH
NORTHPORCH
SOUTH STREET SOUTH STREET
PIER 17BUILDING
PIER 17BUILDING
PROPOSED SITE PLAN
NEW CONSTRUCTION
PIERS AND PLATFORMS
HISTORIC DISTRICT LINE
SOUTH STREET SEAPORT // SITE PLAN
FDR DRIVEFDR DRIVE
ACCESS DRIVEPIER 17 HEAD HOUSE
RECONSTRUCTED TIN BUILDING
EXISTINGTIN BUILDING
16
AC
CES
S D
RIV
E
17
SOUTH STREET SEAPORT // APPROVED + PROPOSED LANDSCAPE MATERIALS
COL.
COL.
COL.COL.
COL.
COL. COL.
COL.
COL.COL.
COL.
COL.
COL.
PIER 17BUILDING NORTH
PORCH
FULTONPLAZA
EAST RIVER ESPLANADE
FULTON MARKET BUILDING
SOUTH STREET
FULT
ON
STR
EET
PIER 16
BEE
KM
AN
STR
EET
AC
CES
S D
RIV
E
SERVICE AREA
ESPLANADE HEX PAVER WOOD DECKING WOOD FURNITURE CONCRETE PAVERBLUESTONEPRECAST CONCRETE PAVER - ROAD
FULTON MARKET BUILDING
SOUTH STREET
FULT
ON
STR
EET
TIN BUILDING
LINKBUILDING
PROPOSED SITE PLANAPPROVED SITE PLAN
COL.
COL.
COL.COL.
COL.
COL. COL.
COL.
COL.COL.
COL.
COL.
COL.
PIER 17BUILDING NORTH
PORCH
FULTONPLAZA
EAST RIVER ESPLANADE
FULTON MARKET BUILDING
SOUTH STREET
FULT
ON
STR
EET
PIER 16
BEE
KM
AN
STR
EET
ACCESS DRIVE
FULTON MARKET BUILDING
SOUTH STREET
FULT
ON
STR
EET
TIN BUILDING
PIER 17PIER 17
18
PIER 17 // ACCESS DRIVE DESIGN // PROPOSED SITE PLAN
P rem Krishn am ur thyP rem Krishn am ur thyP rem Krishn am ur thyP rem Krishn am ur thy
1799.7111
P rem Krishn am ur thyP rem Krishn am ur thy
WESTERN BORDER OF SOUTH STREET
73
R
RC
M
M
M M M M M M M M M RC
BEE
KM
AN
STR
EET
SOUTH STREET
PIER 16
PIER 17BUILDING
(TAX LOT 10)
4s 5.5s 4s 4.5s 4.5s 4.5s 2s 4s 4.5s 4.5s 5s 5s
4s
4s
C
3s
C
3s
C5s
Tu
2s
TIN BUILDING(TAX LOT 11)
NEW MARKET BUILDING(TAX LOT 14)
C4-6/LM
C6-2A/LM
Primary Building Entrance
Zoning Line/DistrictC4-6
Zoning Lot
3575 Tax Block
Street Direction Arrows
60 Street Width
4s Number of Stories
R ResidentialRC Mixed Commercial/Residential
CommercialCManufacturing/IndustrialMTransportation/UtilityTuPublic Facilities & InstitutionsPfOpen Space/ParkPParking FacilitiesPkgVacant LandV
FULT
ON
STR
EE
T(P
EDE
STR
IAN
ZO
NE
)
US PIERHEAD AND BULKHEAD LINE
Visual Corridor Extents
0' 80' 120' 160'40'
GRAPHIC SCALE
KEY
P
1s
FDR ABOVE
FDR ABOVE
SIGNAL
NOTE: ANY ELEMENTS OUTSIDE THE ZONING LOT ARE SHOWNFOR ILLUSTRATIVE PURPOSES ONLY.ALL ELEVATIONS MARKERS ARE IN MANHATTAN HIGHWAYDATUM, WHICH IS 2.75 FEET ABOVE THE NATIONAL GEODETICSURVEY DATUM OF 1929, MEAN SEA LEVEL, SANDY HOOK, NEWJERSEY.
Beekman Extension
SOUTH STREET
Legal Street BoundaryNon Valid Visual Corridor Extents
32' - 0"
24' -
0"
STAGELOCATION
BIKE LANE
FULTONPLAZA
NORTHPORCH
28' -
4"
29' -
8"
SIGNAL
76' - 1"
87' - 6"
87' - 6"
101' - 1"
83' - 8"
38' - 0"
200'
- 8"
42' - 2"
130' - 6"
34' - 5"
268'
- 8"
360'
- 9"
46' - 2"
263'
- 5"
42' - 2"
130' - 6"
34' - 5"
267'
- 7"
411' - 5"
194' - 10"
316' - 8"
EXISTINGBIKE LANE
MARGINAL STREET EAST RIVER WATERFRONTESPLANADE EXTENSION
LAY-BY LANE
BUS STOP
ACCESS DRIVE
64' -
8"
57' - 6"
20' - 0"
25' -
0"
15' - 0"
35' - 4"
SHoP ARCHITECTS, P.C.
11 PARK PLACE, PENTHOUSENEW YORK, NY 10007
tel 212.889.9005
ARCHITECT
DRAWING TITLE
DRAWING NUMBER
DATE
DRAWN BY
CHECKED BY
PROJECT NO.
THESE DRAWINGS AREINSTRUMENTS OF SERVICE ANDAS SUCH MAY NOT BE USED FOROTHER PROJECTS, FORADDITIONS TO THIS PROJECT ORCOMPLETION OF THIS PROJECTBY OTHERS.
MEP ENGINEER
SCHNACKEL ENGINEERS53 WEST 36TH STREETNEW YORK, NY 10018
212.366.4813tel
tel
STRUCTURAL ENGINEER
BURO HAPPOLD100 BROADWAYNEW YORK, NY 10005
212.334.2025
LIGHTING DESIGNER
L'OBSERVATOIRE INTERNATIONAL120 WALKER STREET 7TH FLOOR EASTNEW YORK, NY 10013
212.255.4463tel
DATE ISSUE/REVISION
DOB NO. 000000000
LANDSCAPE ARCHITECT
James Corner Field Operations475 10th Ave, 10th floorNew York NY 10018
212.433.1450tel
CODE CONSULTANT
Code Consultants Inc215 West 40th Street 15 floorNew York NY 10018
212.216.9596tel
VERTICAL CIRCULATION
Van Deusen and Associates5 Regent StreetLivingston, NJ 07440
973.994.9220tel
SIGNAGE AND IDENTITY
Pentagram200 Fifth AvenueNew York, NY 10010
212.683.7000tel
07.13.14 SUBSTANTIAL COMPLIANCE
02.05.13 ULURP SUBMISSION
02.05.16
06.08.16 MINOR MODIFICATION
NOT FOR CONSTRUCTION
7/15
/201
6 11
:34:
02 A
M
ASK-001
Illustrative SitePlan
101015
Author
Checker
PIE
R 1
789
SO
UTH
STR
EE
TN
EW
YO
RK
, NY
1003
8
1" = 40'-0"ASK-001
1Copy of 00. SITE PLAN -
1’ 20' - 0" 1’ 16’-3”
ACCESS DRIVE SIDEWALK WOOD DECK
TINBUILDING
TINBUILDING
TINBUILDING
30’-0”
SIDEWALK
1’ 20' - 0" 1’ 16’-3”
ACCESS DRIVE SIDEWALK WOOD DECK
33’-0”
SIDEWALK
36’-0” 1’ 20' - 0" 1’ 16’-3”
ACCESS DRIVE SIDEWALKSIDEWALK HEX PAVERS
SOUTH STREET SEAPORT // HARDSCAPE / ACCESS DRIVE / SECTIONS
SECTION 1
SECTION 2
SECTION 3
1
2
3
19
TINBUILDING
10’-0” 27' - 5" 12' - 0" 8'-6" - 20’-0”
EAST RIVER ESPLANADE
FDR DRIVE
BIKE LANE SIDEWALK SOUTHSTREET
39’-0”
TIN BUILDING ENTRY SEAT-STEPS
TIN BUILDING
6"
SOUTH STREET SEAPORT // HARDSCAPE / ESPLANADE / SECTION
20
21
4” CURB
20’
1’
1’
ACCESS DRIVE
SIDEWALK / PLAZA
ESPLANADE
SOUTH STREET SEAPORT // HARDSCAPE // ACCESS DRIVE TYPICAL SECTION
22
SOUTH STREET SEAPORT // HARDSCAPE // SEATING STEPS
*FDR OMITTED FOR CLARITY
2321
PIER 17 // GENERAL LANDSCAPE DESIGN // LIGHTING // EXISTING CONDITIONS
APPROX. 16’
APPROX. 25’-30’
SOUTH STREET SEAPORT // LIGHTING // EXISTING CONDITIONS
24
SOUTH STREET SEAPORT // LIGHTING // PROPOSED
16’
25
SOUTH STREET SEAPORT // VIEW OF EAST FACADE FROM THE SOUTH
26
SOUTH STREET SEAPORT // VIEW OF EAST FACADE FROM THE NORTH
27
SOUTH STREET SEAPORT // VIEW FROM SOUTH STREET
28
SOUTH STREET SEAPORT // BEEKMAN STREET VIEW
29
SOUTH STREET SEAPORT // VIEW FROM BEEKMAN STREET AND SOUTH STREET
30
SOUTH STREET SEAPORT // LIST OF ACTIONS
• Modification of 2013 special permits to enlarge the zoning lot and modify the site plan subject to the special permits:
• Waterfront Authorization (ZR Section 62-822(b)): design of waterfront public access areas – to approve new design on the Tin Building site and the former Link Building site.
• Waterfront Certification (ZR Section 62-811): to approve the design for the waterfront public access areas, as modified by the new Authorization.
o Waterfront height and setback special permit (ZR Section 62-834): shift in Pier 17 building;
o Large-scale signage special permit (ZR Section 74-744(c)): Pier 17 Building west façade and Tin Building signage; and
o Large-scale waterfront yard special permit (ZR Section 74-743(a)(2)): no change in yards.