+ All Categories
Home > Documents > Junction Boxes Enclosures

Junction Boxes Enclosures

Date post: 10-Feb-2018
Category:
Upload: john-arllan-diestro
View: 224 times
Download: 0 times
Share this document with a friend

of 13

Transcript
  • 7/22/2019 Junction Boxes Enclosures

    1/13

    TERMINAL BOXES

    ELECTRICAL ENCLOSURES

    HAZARDOUS AREA ENCLOSURES

    SPECIAL PURPOSE ENCLOSURES

    ABTECH

    ENCLOSURE SPECIALISTS FOR THE ELECTRONICS, INSTRUMENTATION,

    MARINE, OIL, GAS AND PETRO-CHEMICAL INDUSTRIES

  • 7/22/2019 Junction Boxes Enclosures

    2/13

    A B T E C H B P G R A N G E

    The BPG range comprises 16 sizes of

    enclosure manufactured in glass reinforced

    polyester. The polyester is highly resistant to

    contamination from oils, fats, aliphatic and

    aromatic carbohydrates, bacteria and

    enzymes. It is also suitable for LSOH (low

    smoke zero halogen) applications. This

    material gives excellent mechanical strength

    and life expectancy. The wall thickness is

    sufficient to allow tapped entry holes to be

    machined in the walls of the enclosure and itprovides a very good alternative to

    aluminium or cast iron.

    Abtech mould the BPG range from SMC

    material rather than DMC which is the most

    common form of GRP. In this method the

    glass reinforcement takes the form of sheets

    rather than short strands. This gives much

    greater mechanical strength and also in the

    event of the enclosure being exposed to fire

    conditions the structure holds together even

    if the resin is depleted due to the elevated

    temperatures as demonstrated by the fact

    that the BPG range when fitted with ceramic

    terminals meets the requirements of IEC 331

    (750C for 3 hours) and also BS6387/1983

    (950C for 3 hours - flame only).

    Due to the enclosures labyrinth seal system,

    whereby the seal is protected from external

    forces, the BPG enclosure has excellent

    ingress protection qualities which mean thatthe enclosure is tested to and passed

    IP66/67 and has also undergone and

    passed the Shell/ERA deluge test which was

    devised to adequately test enclosures and

    electrical equipment which is routinely

    subjected to ships decks conditions or fire

    deluge systems. The mounting holes,

    although contained within the profile of the

    enclosure, sit outside the seal and all

    external fasteners and fixings are

    manufactured from 316 grade stainless steel

    to ensure reliability.

    The BPG range has many features which

    lend itself to a whole host of applications

    including both industrial and hazardous

    area, junction boxes, OEM applications, fire

    protection systems, tunnel wiring etc. The

    BPG range can be machined, drilled, tapped

    with various thread forms, painted and of

    course it can be moulded in a variety of

    colours which gives a much improved

    durability of colour over painting.

    The BPG range is also available carbon

    loaded (BPGC) which helps to reduce the

    surface resistance of the material and

    consequently reduce the risk of spark from

    static build up.

    Earthing can be acomplished by various

    means. External/internal earth stud which inturn can be connected to the termina

    mounting rail or component mounting plate,

    an ECP (earth continuity plate) can be fitted

    around the inner walls to provide continuity

    for cable glands and various in rail mounted

    earth terminals or proprietary earth bars can

    be fitted inside the enclosure.

    When fitted with a standard neoprene gasket

    the enclosure is suitable for ambient

    temperatures of -40C to 80C. Alternatively

    when fitted with an optional silicone gasket

    the temperature range is increased to -70C

    to 130C. For certified apparatus contact

    Sales Department for ambient operating

    temperatures.

    The BPG and BPGC enclosures are suitable

    for use in hazardous areas and can be

    supplied with a number of certificates,

    specifically ATEX EEx e to BS EN 50019

    (zone 1 & 2) EEx nA to BS EN50021 (zone

    2) and NEMA 4X (CSA, UL & FM class 1, div

    2). The BPG range can be supplied fitted

    with any component approved terminal to

    apparatus level or can be supplied empty as

    component approved for the clients own

    certification requirements.

  • 7/22/2019 Junction Boxes Enclosures

    3/13

    A B T E C H B P G R A N G E

    ECPCopper earth continuity plate.(Must also be fitted with earth stud)

    ESEarth Stud.(May be brass or stainless steel)

    ALAllen head fixing screw.(Stainless steel grade 316)

    TPTamper-proof screws.(Requires special tool for removal)

    HExternal hinges.

    MComponent mounting plate.(Tufnol - standard, steel - option)

    FExternal mounting feet.(Stainless steel grade 316)

    EInternal earthing bar.(Can be fitted with clamps)

    TDIN standard mounting rail.(TS15, TS32 or TS35, please specify)

    A C C E S S O R I E SThe following table is a list of the available accessories suitable for particular sizes of BPG enclosures. Care should be taken when ordering

    accessories for use with enclosures intended for hazardous areas to ensure that compliance with certification is retained.

    SIZE DIMENSIONSC Ex ECP ES AL TP H M F E SIL T RFI

    BPG1 80 x 75 x 55 n n n n n n n n n

    BPG2 110 x 75 x 55 n n n n n n n n n

    BPG3 160 x 75 x 55 n n n n n n n n n

    BPG4 190 x 75 x 55 n n n n n n n n n

    BPG4.5 190 x 75 x 75 n n n n n n n n n

    BPG5 230 x 75 x 50 n n n n n n n n n

    BPG6 122 x 120 x 90 n n n n n n n n n n n n n

    BPG7 220 x 120 x 90 n n n n n n n n n n n n n

    BPG8 160 x 160 x 90 n n n n n n n n n n n n n

    BPG9 260 x 160 x 90 n n n n n n n n n n n n n

    BPG10 360 x 160 x 90 n n n n n n n n n n n n n

    BPG11 560 x 160 x 90 n n n n n n n n n n n n n

    BPG12 255 x 250 x 120 n n n n n n n n n n n n n

    BPG13 400 x 250 x 120 n n n n n n n n n n n n n

    BPG14 600 x 250 x 120 n n n n n n n n n n n n n

    BPG15 400 x 405 x 120 n n n n n n n n n n n n n

    C - Carbon Loaded (gives surface tracking value of between 106and 109 ohms).

    Ex - Ex certified (may be component or apparatus certified - please specify requirements).

    RFI - Fitted with RFI gasket and internally coated with RFI sheilding (depending on gasket used, may reduce IP rating).

    SIL - Silicone gasket giving greater temperature range (may also increase life when used in certain applications).

  • 7/22/2019 Junction Boxes Enclosures

    4/13

    SCSPOWER

    RATING(S)

    NO.OFROWS

    BK

    4(4way

    BK6(6way)

    BK

    12(12way)

    MK6/4

    MK6/6

    SAK2.5

    SAK4

    SAK6N

    SAK10

    SAK16

    SAK35

    GS/4(4way)

    GS/6(6way)

    GS/12(12way)

    K3

    UK3

    K5

    UK5

    K10

    UK10

    K16

    UK16

    UK35

    WEIDMULLER PHOENIX

    SIZE

    WAGO

    8.390

    8.551

    8.833

    9.012

    9.260

    9.378

    10.500

    10.34811.933

    13.793

    18.338

    15.474

    15.474

    20.867

    20.867

    30.384

    30.384

    31.350

    31.350

    31.350

    SIZE

    Solid mm2 4 4 4 6 6 4 6 10 16 16 501 4 4 4 4 4 4 4 10 10 16 16 35

    Stranded mm2 4 6 10 16 16 35 4 6 10 16 35 4 4 4 2.5 2.5 4 4 6 6 10 10 35

    CURRENT(A) 21 21 21 26 26 21 28 36 50 66 21 21 21 21 21 21 21 37 37 47 47 75

    TERMINAL TYPE

    BOX TYPE

    BPG 1 1 1 1 - 1 - - - - - - - 1 1 - - - - - - - - - -

    BPG 2 1 2 1 - 1 1 - - - - - - 2 1 - - - - - - - - - -

    BPG 3 1 3 - 1 2 1 - - - - - - 3 2 1 - - - - - - - - -

    BPG 4 1 4 - 1 3 2 - - - - - - 4 3 1 - - - - - - - - -

    BPG 5 1 5 3 2 4 2 - - - - - - 5 3 2 - - - - - - - - -

    BPG 6 1 - - - - - 10 9 7 6 5 3 - - - 12 12 10 10 6 6 6 6 4

    BPG 7 1 - - - - - 26 24 20 16 13 10 - - - 30 30 25 25 19 19 15 15 10

    BPG 8 1 - - - - - 16 15 12 9 8 5 - - - 19 19 16 16 12 12 9 9 5BPG 9 1 - - - - - 33 30 25 20 16 12 - - - 38 38 32 32 24 24 19 19 13

    BPG 10 1 - - - - - 48 45 36 29 24 18 - - - 56 56 48 48 36 36 29 29 18

    BPG 11 1 - - - - - 80 74 61 48 41 30 - - - 94 94 78 78 58 58 46 46 32

    BPG 12 1 - - - - - 31 29 24 19 16 12 - - - 37 37 31 31 23 23 18 18 12

    BPG 12 2 - - - - - 62 58 48 38 - - - - - 74 74 62 62 46 46 36 36 -

    BPG 13 1 - - - - - 55 50 41 33 27 20 - - - 64 64 53 53 40 40 32 32 22

    BPG 13 2 - - - - - 110 100 82 66 - - - - - 128 128 106 106 80 80 64 64 -

    BPG 14 1 - - - - - 87 81 66 52 41 32 - - - 103 103 86 86 64 64 51 51 34

    BPG 14 2 - - - - - 174 162 132 104 82 64 - - - 206 206 172 172 128 128 102 102 -

    BPG 15 1 - - - - - 55 50 41 33 27 20 - - - 64 64 53 53 40 40 32 32 22

    BPG 15 2 - - - - - 110 100 82 66 54 - - - - 128 128 106 106 80 80 64 64 -

    BPG 15 3 - - - - - 110 100 82 66 81 - - - - 192 192 159 159 120 120 - - -

    The above power ratings apply to an ambient operating temperature of 40C. Reduced power ratings are available for ambient temperatures up to +65C.

    A B T E C H B P G R A N G E

    Stranded mm2 2.5 2.5 4 4 4 6 10 16 35 2.5 4 2.5 2.5 2.5 2.5 2.5 2.5

    CURRENT(A) 23 20 30 30 30 39 53 72 120 23 30 23 23 23 23 23 23

    TERMINAL TYPE

    BOX TYPE

    BPG 1 8.390 1 - - - - - - - - - - - 6 3 6 3 6 3

    BPG 2 8.551 1 - - - - - - - - - - - 10 5 10 5 10 5

    BPG 3 8.833 1 - - - - - - - - - - - 18 9 18 9 18 9

    BPG 4 9.012 1 - - - - - - - - - - - 24 12 24 12 24 12

    BPG 5 9.260 1 - - - - - - - - - - - 30 15 30 15 30 15

    BPG 6 9.378 1 14 14 12 12 12 9 7 6 - 14 12 12 6 12 6 12 6

    BPG 7 10.500 1 32 32 27 27 27 21 17 14 - 32 27 27 13 27 13 27 13

    BPG 8 10.348 1 19 19 16 16 16 13 10 8 - 19 16 16 8 16 8 16 8

    BPG 9 11.933 1 38 38 33 33 33 25 20 17 - 38 33 33 16 33 16 33 16

    BPG 10 13.793 1 56 56 49 49 49 38 30 25 - 56 49 49 24 49 24 49 24

    BPG 11 18.338 1 94 94 81 81 81 62 50 42 - 94 81 81 40 81 40 81 40

    BPG 12 15.474 1 36 36 32 32 32 25 20 16 11 36 32 32 16 32 16 32 16

    BPG 12 15.474 2 72 72 64 64 64 50 40 32 - 72 64 64 32 64 32 64 32

    BPG 13 20.867 1 65 65 55 55 55 42 34 28 19 65 55 55 27 55 27 55 27

    BPG 13 20.867 2 130 130 110 110 110 84 68 56 - 130 110 1 10 55 110 55 110 55

    BPG 14 30.384 1 102 102 88 88 88 67 54 45 31 102 88 88 44 88 44 88 44

    BPG 14 30.384 2 104 104 176 176 176 134 108 90 - 104 176 176 88 176 88 176 88

    BPG 15 31.350 1 130 130 55 55 55 42 34 28 19 130 55 55 27 55 27 55 27

    BPG 15 31.350 2 260 260 110 110 110 84 68 56 - 260 110 1 10 55 110 55 110 55

    BPG 15 31.350 3 390 390 165 165 165 126 102 84 - 390 165 165 81 165 81 165 81

    SCS

    POWER

    ratings

    (W)

    NO.

    OFROWS

    280

    -

    991

    280

    -

    699

    281

    -

    691

    281-

    991

    281

    -

    695

    282

    -

    691

    284

    -

    691

    283

    -

    691

    285

    -

    691

    280

    -

    698

    281

    -

    693

    264

    -

    120

    264

    -

    220

    2642Cond.

    Strip

    2644Cond.

    Strip

    2622Cond.

    Strip

    2624Cond.

    Strip

    The above power ratings apply to an ambient operating temperature of 40C. Reduced power ratings are available for ambient temperatures up to +65C.

    In some instances the terminal content shown above exceeds the power rating if all terminals are used at full certified current rating. In this instance steps

    should be taken to ensure the power rating is not exceeded.

    The ABTECH BPG Ex range, when fitted with any component certified EExe terminals, is Sira ATEX certified to EN 50 014 and EN 50 019. The empty enclosure

    is component certified and available for adding clients components subject to final approval by Sira or any recognised certifying authority. ABTECH have many

    years experience in the application of enclosures in hazardous areas and will be pleased to offer advice for any enclosure problems.

    The power rating refers to the permitted power losses inside the enclosure. It is the responsibility of the user to keep power losses within these limits. Annex C2

    T E R M I N A L C O N T E N T SThe following tables are provided as a guide only. Due to space limitations only Weidmuller, Wago and Phoenix terminal populations are shown. Any

    component certified terminal may be fitted to the BPG range provided compliance with the terminal manufacturers component certificate is adhered to.

  • 7/22/2019 Junction Boxes Enclosures

    5/13

    A B T E C H B P G R A N G E

    ab123

    Glass reinforced polyester enclosures offering protection to IP 67.Temp range -40C to 80C with standard gasket or -70C to 130Cwith silicone gasket. Standard finish as moulded isRAL 7001 grey or black for BPGC.Can be moulded in variety of colours.

    BPG 2/BPGC 2Size: 110 x 75 x 55mmWeight: 230gRating: 8.551Watts

    BPG 1/BPGC 1Size: 80 x 75 x 55mmWeight: 230gRating: 8.390Watts

    BPG 3/BPGC 3Size: 160 x 75 x 55mmWeight: 405gRating: 8.833Watts

    BPG 4/BPGC 4Size: 190 x 75 x 55mmWeight: 450g

    Rating: 9.012Watts

  • 7/22/2019 Junction Boxes Enclosures

    6/13

    A B T E C H B P G R A N G E

    ab123

    Glass reinforced polyester enclosures offering protection to IP 67.Temp range -40C to 80C with standard gasket or -70C to 130Cwith silicone gasket. Standard finish as moulded isRAL 7001 grey or black for BPGC.Can be moulded in variety of colours.

    BPG 6/BPGC 6Size: 122 x 120 x 90mmWeight: 750gRating: 9.378Watts

    BPG 5/BPGC 5Size: 230 x 75 x 50mmWeight: 529gRating: 9.260Watts

    BPG 7/BPGC 7Size: 220 x 120 x 90mmWeight: 1060gRating: 10.500Watts

    BPG 8/BPGC 8Size: 160 x 160 x 90mmWeight: 1130g

    Rating: 10.348Watts

    76

    110

  • 7/22/2019 Junction Boxes Enclosures

    7/13

    A B T E C H B P G R A N G E

    ab123

    Glass reinforced polyester enclosures offering protection to IP 67.Temp range -40C to 80C with standard gasket or -70C to 130Cwith silicone gasket. Standard finish as moulded isRAL 7001 grey or black for BPGC.Can be moulded in variety of colours.

    BPG 10/BPGC 10Size: 360 x 160 x 90mmWeight: 2150gRating: 13.793Watts

    BPG 9/BPGC 9Size: 260 x 160 x 90mmWeight: 1170gRating: 11.933Watts

    BPG 11/BPGC 11Size: 560 x 160 x 90mmWeight: 3200gRating: 18.338Watts

    BPG 12/BPGC 12Size: 255 x 250 x 120mmWeight: 2656g

    Rating: 15.474Watts

  • 7/22/2019 Junction Boxes Enclosures

    8/13

    A B T E C H B P G R A N G E

    ab123

    Glass reinforced polyester enclosures offering protection to IP 67.Temp range -40C to 80C with standard gasket or -70C to 130Cwith silicone gasket. Standard finish as moulded isRAL 7001 grey or black for BPGC.Can be moulded in variety of colours.

    BPG 15/BPGC 15Size: 400 x 405 x 120mmWeight: 5580gRating: 31.350Watts

    BPG 14/BPGC 14Size: 600 x 250 x 120mmWeight: 5235gRating: 30.384Watts

    BPG 13/BPGC 13Size: 400 x 250 x 120mmWeight: 3650gRating: 20.867Watts

  • 7/22/2019 Junction Boxes Enclosures

    9/13

    A B T E C H B P G A R A N G E

    The Abtech BPGA range comprises three types of

    BPG enclosures in two different sizes which are

    available pre-assembled and readily available off the

    shelf. They are ideal for a range of uses such as

    lighting, power and instrument junction boxes.

    They are manufactured in impact resistant glass

    reinforced polyester which has an ingress protection

    rating of IP66/67 and are Shell/ERA deluge tested.

    The enclosures come equipped with terminals as shown

    in the table below, copper earth continuity plate and

    brass M6 internal/external earth stud. The enclosure is

    pre-drilled with four M20 tapped cable entries and is

    supplied complete with EEx e certified blanking plugs.

    The range is ATEX certified EEx e and is suitable for

    use in Category 2/Zone 1 and Category 3/Zone 2 areas

    according to EN 60079-14 with a working ambient

    temperature of between -20C and +40C.

    SPECIFICATION BPGA 120 BPGA 125 BPGA 160

    Size (external) 122 x 120 x 90 122 x 120 x 90 160 x 160 x 90

    Entries 4 x M20 (2 x A, 2 x C) 4 x M20 (2 x A, 2 x C) 4 x M20 (2 x A, 2 x C)

    EEx e Blanking plugs 3 3 3

    Terminals 6 x SAK 2.5 1 x MK6/6 way 13 x SAK 2.5

    Links Linked in pairs Linked in pairs na

    Int/Ext M6 earth stud Yes Yes Yes

    Copper earth continuity plate Yes Yes Yes

    Ingress Protection (IP) IP 66/67 IP 66/67 IP 66/67

    Shell/ERA Deluge tested Yes Yes Yes

  • 7/22/2019 Junction Boxes Enclosures

    10/13

    A B T E C H S X R A N G E

    The SX range comprises 14 sizes of

    enclosure manufactured in either mild steel

    or stainless steel. Depending on the

    enclosure size they are available in standard

    depths of 140, 200 or 300mm and can be

    fitted with removable gland plates on any or

    all of the four sides. The mild steel version

    (MSX) is available with a number of paint

    options (most RAL colours available) and

    anti corrosion finishes and advice on this can

    be sought from Abtech.

    The stainless steel range (SSX) is

    manufactured in 316 grade stainless steel to

    give the maximum environmental protection.

    The main body is manufactured from 2mm

    thick sheet and the mounting straps and

    gland plates from 3mm thick plate.

    Cable entries can be drilled in the sides or

    through the gland plates, if fitted, or through

    the enclosure wall. Entries may also be

    drilled through the rear face of the enclosure

    (EEx versions also.)

    The SX range was specifically designed to

    meet the rigours of the North Sea

    environment and is capable of achieving

    IP66 and IP67 and has also undergone andpassed the Shell/ERA deluge test which was

    devised to adequately test enclosures and

    electrical equipment which is routinely

    subjected to ships decks conditions or fire

    deluge sytems.

    IP68 enclosures are aslo available for depths

    up to 120 ft to special order.

    Another advantage of the SX range is that it

    is suitable for fire resistance applications

    and when fitted with ceramic terminals

    meets the requirements of IEC 331 (750C

    for 3 hours) and also BS6387/1983 (950C

    for 3 hours).

    Another important feature of the SX range is

    the door, which is held to the enclosure by at

    least 4 captive stainless steel screws, which

    also maintain the correct compression onthe gasket. The hinges are solid block,

    machined oversize to enable the screws to

    control the closing of the door, not the hinge,

    its only function being to support the door

    when opened. The hinges allow easy

    removal of the door with only minimal

    opening required before removal (less than

    10).

    The SX range has many features which lend

    itself to many applications, not least of which

    is the ability to be constructed to almost any

    dimension due to its fabricated nature. This

    can also be applied to EEx enclosures

    where the certification allows oversize

    enclosures to be manufactured whilst

    retaining the next smallest sized enclosures

    power rating. Other applications include

    junction boxes, both industr ial and

    hazardous area, OEM applications, fire

    protection systems, tunnel wiring, IP68

    applications, etc.

    Earthing is accomplished by means of an

    external/internal earth stud fitted as standard

    which can be connected to the termina

    mounting rail or component mounting plate

    and optionally earth studs can be fitted tothe door and gland plates. Rail mounted

    earth terminals or proprietary earth bars can

    be fitted inside the enclosure and Abtech

    sales staff will be happy to advise on this.

    When fitted with a standard neoprene

    gasket, the enclosure is suitable for ambient

    temperatures of -40Cto 80C. Alternatively

    when fitted with an optional silicone gasket

    the temperature range is increased to -70C

    to 130C.

    The SX range of enclosures are suitable for

    use in hazardous areas and can be supplied

    with a number of certificates. ATEX EEx e to

    BS EN 50019 (Zone 1 & 2) EEx nA to BS

    EN50021 (Zone 2) and NEMA 4X (CSA, UL &

    FM class 1, div 2). The SX range can be

    supplied fitted with any component

    approved terminal to apparatus level or can

    be supplied empty as component approved

    for the clients own certification requirements.

  • 7/22/2019 Junction Boxes Enclosures

    11/13

    A B T E C H S X R A N G E

    GPGland plates.(Please specify sides to be fitted)

    ESEarth Stud fitted to door and gland

    plates. (If fitted - specify size req.)

    ELElectro-polished.(External surface 316 SS only)

    LBLabel bracked.

    (Welded to door - specify size)

    MComponent mounting plate.(Steel or stainless steel)

    EInternal earthing bar.

    (Can be fitted with clamps)

    A C C E S S O R I E SThe following table is a list of the available accessories suitable for particular standard sizes of SX enclosures. Care should be taken when ordering

    accessories for use with enclosures intended for hazardous areas to ensure that compliance with certification is retained.

    Size Dimensions GP 140 200 300 EL LB ES E SIL BD TP M RFI

    SX45 114 x 114 x 51 n n n n n n n

    SX64 102 x 152 x 63 n n n n n n n

    SX66 152 x 152 x 102 n n n n n n n n n n

    SX0 152 x 229 n n n n n n n n n n n n

    SX0.5 184 x 274 n n n n n n n n n n n n

    SX1 234 x 324 n n n n n n n n n n n n

    SX1.5 306 x 306 n n n n n n n n n n n n

    SX2 372 x 324 n n n n n n n n n n n n

    SX3 372 x 448 n n n n n n n n n n n n

    SX4 372 x 510 n n n n n n n n n n n n

    SX5 510 x 510 n n n n n n n n n n n n

    SX6 510 x 780 n n n n n n n n n n n n n

    SX7 650 x 950 n n n n n n n n n n n n n

    SX8 800 x 1250 n n n n n n n n n n n n n

    All SX range enclosures are available manufactured in either mild steel - MSX or stainless steel grade 316 - SSX

    All SX range enclosures are available Ex certified (component or apparatus certified - please specify requirements)

    All SX range enclosures meet IP66/67. When fitted with gland plates the standard IP rating is IP66. IP67 available as option.

    RFI - Fitted with RFI gasket (depending on gasket used, may reduce IP rating)

    SIL - Silicone gasket giving greater temperature range. (may also increase life when used in certain applications)

    EL - Electropolished external enclosure surface (stainless steel 316 only)

    BD - Breather drain (IP66 stainless steel or plastic)

    TP - Tamper-proof lid fixing screws

    DEPTH

  • 7/22/2019 Junction Boxes Enclosures

    12/13

    SCSPOWER

    RATING(S)

    NO.OFROWS

    SAK2.5

    SAK6

    SAK6

    SAK10

    SAK16

    SAK35

    SAK70

    UK2.5B

    UK3

    UK5

    UK10

    UK16

    UK35

    KLIPPON PHOENIX

    SIZE

    WAGO

    T E R M I N A L C O N T E N T SThe following table is provided as a guide and due to space limitations in this brochure only Klippon, Wago and Phoenix terminal

    populations are shown. All Abtech enclosures are available empty or alternatively may be provided with terminals, entries, accessories and

    other electromechanical components.

    Solid mm2 4 6 10 16 16 35 70 2.5 4 4 10 16 35

    Stranded mm2 4 4 6 10 16 35 70 2.5 2.5 4 6 10 35

    ATEX CURRENT(A) 15 22 26 37 47 75 - - - - - - -

    TERMINAL TYPE

    BOX TYPE

    SX 45 1 6 - - - - - - 6 9 - - - -

    SX 64 10.258 1 14 12 10 8 - - - 14 16 10 8 - -

    SX 66 14.287 2 14 12 10 8 7 4 - 14 16 10 8 7 4

    SX 0 19.874 1 17 15 13 10 8 6 3 17 20 13 10 8 6

    SX 1 29.206 1 25 25 21 17 14 9 9 25 34 21 17 14 9

    SX 1.5 32.284 2 48 48 40 32 13 8 9 48 68 40 32 13 8

    SX 2 36.500 2 50 50 42 34 14 9 9 50 68 42 34 14 9

    SX 3 42.289 2 90 90 76 60 25 16 12 90 118 76 60 25 16

    SX 4 44.726 2 110 110 90 72 30 20 16 110 140 90 72 30 20

    SX 5 50.238 3 165 165 135 108 60 40 32 165 210 135 108 60 40

    SX 6 57.383 3 300 300 234 189 104 70 58 300 366 234 189 104 70

    SX 7 68.000 3 408 408 300 240 198 132 100 408 465 300 240 198 132

    4 544 544 400 320 - - - 544 620 400 320 - -

    SX 8 119.463 5 915 845 685 550 455 244 230 915 1060 686 550 455 244

    6 1098 1014 822 660 - - - 1908 1272 822 660 - -

    The above power ratings apply to an ambient operating temperature of 40C. Reduced power ratings are available for ambient temperatures up to +65C.

    A B T E C H S X R A N G E

    BOX TYPE

    SX 45 8.950 1 6 - 5 5 - - - - - 6 5 6 3 6 6 5 4 6 3 6 3

    SX 64 10.258 1 12 - 10 10 - - - - - 12 10 12 6 12 12 10 7 12 7 12 6

    SX 66 14.287 1 12 12 10 10 10 9 7 6 - 12 10 12 6 12 12 10 7 12 7 12 6

    SX 0 19.874 1 21 21 18 18 18 14 11 - - 21 18 10 12 19 14 11 9* 20 12 20 9

    SX 1 29.206 1 35 35 29 29 29 23 18 15 10 35 29 32 19 30 23 18 18 32 19 32 15

    SX 1.5 32.284 2 70 70 58 58 58 46 36 30 10 70 58 64 38 60 46 36 36 64 38 64 30

    SX 2 36.500 2 70 70 58 58 58 46 36 30 10 70 58 64 38 60 56 36 36 64 38 64 30

    SX 3 42.289 2 118 118 100 100 100 78 62 52 18 118 100 106 64 104 78 62 62 106 64 106 52

    SX 4 44.726 2 140 140 120 120 120 92 74 62 21 140 120 126 76 124 92 74 74 126 76 126 62

    SX 5 50.238 3 210 210 180 180 180 138 111 93 42 210 180 189 114 186 138 111 111 189 114 189 93

    SX 6 57.383 3 360 360 300 300 300 130 189 156 74 360 300 15 192 318 240 189 189 315 192 314 156

    SX 7 68.000 3 450 450 390 390 390 300 240 195 135 450 390 405 240 390 300 240 240 405 240 405 195

    4 600 600 520 520 520 400 320 260 - 600 520 540 320 520 400 320 320 540 320 540 260

    SX 8 119.463 5 1000 1000 875 875 875 675 550 450 252 1000 875 925 550 920 675 550 550 925 550 925 450

    6 1200 1 200 1 050 1 050 1 050 810 660 540 - 1200 1 050 1 110 610 1104 810 660 660 1110 650 1110 540

    In some instances the terminal content shown above exceeds the power rating if all terminals are used at full certified current rating. In this instance steps should be taken to ensure the

    power rating is not exceeded.

    The ABTECH SX Ex range, when fitted with any EExe component approved terminals(1) is Sira certified to EN 50 014 and EN 50 019. The empty enclosure is component certified and

    available for adding clients components subject to final approval by Sira or any suitable notified body. ABTECH have many years experience in the application of enclosures in hazardous

    areas and will be pleased to offer advice for any enclosure problems.

    (1) Any apparatus certified enclosure built after June 2003 must be fitted with ATEX approved terminals or components. Abtech sales staff can provide help and information on anyaspect of

    certification in relation to Abtech enclosures.

    The power rating refers to the permitted power losses inside the enclosure. It is the responsibility of the user to keep power losses within these limits. Annex C2 of BS EN 50019 details the

    appropriate calculation method.

    SCS

    POWE

    R

    ratings

    (W

    )

    NO.

    OFROW

    S

    280

    -

    991

    280

    -

    699

    281

    -

    691

    281-

    991

    281

    -

    695

    282

    -

    691

    284

    -

    691

    283

    -

    691

    285

    -

    691

    280

    -

    698

    281

    -

    693

    264

    -

    120

    264

    -

    220

    281

    -

    191

    282

    -

    191

    284

    -

    191

    283

    -

    191

    2642Cond.

    Strip

    2644Cond.

    Strip

    2622Cond.

    Strip

    2624Cond.

    Strip

  • 7/22/2019 Junction Boxes Enclosures

    13/13

    A B T E C H S X R A N G E

    abMild steel or stainless steel enclosures offering protection toIP 67. Temp range -40C to 80C with standard gasket or -70Cto 130C with silicone gasket.

    MSX/SSX 64Size: 102 x 152 x 102mmWeight: 1.5kgRating: 10.258Watts

    MSX/SSX 45Size: 114 x 114 x 51mmWeight: 1.2kgRating: 8.950Watts

    MSX/SSX 66Size: 152 x 152 x 102mmWeight: 2.2kgRating: 14.287Watts

    MSX/SSX 0Size: 229 x 152 x 140/200mmWeight: 3.2kg (140)

    4.0kg (200)Rating: 19.874Watts


Recommended