Date post: | 02-Jun-2018 |
Category: |
Documents |
Upload: | m-abdullah-reza-dh |
View: | 214 times |
Download: | 0 times |
of 14
8/11/2019 K045en97
1/14
K045en.ppt 1998-10
Multi ChannelAveraging Wind Display
Easy to use & install
High contrast
Automatic brightness control
Software configurable
Desktop, wall or panel mounting
WIND 30 Display
8/11/2019 K045en97
2/14
K045en.ppt 1998-10
Display - Speed 3 digits (integer/decimal) - Speed Resolution 0.1 (speed units) - Max, Min/Ch 3 digits - Direction 36 analog segments
- Dir. Resolution 10 degrees - Variation 36 analog segmentsInputs - Digital frequency for anemometer
- Parallel 6-bit for wind vane- Analog 4 ch (u/i) for transmitter/sensor
Outputs - Relay 8 V, 100 mA- Reference 3.5 VDC, 1 mA
Serial - RS-input optoisolated (sw uart)- RS485 i/o 2 wire
or - RS485 i/o 4 wireand - com. module RS, CAN, MODEM, ..Power Supply 10.5 .. 15.5 VDC, 15WIntensity control automatic & manualConfigurability sofwareWeight 580 gSize 144*144 mm, 65 mmEMC CE
Technical Data
8/11/2019 K045en97
3/14
K045en.ppt 1998-10
Wind direction(with 5 s variance)
Wind speed(integer/decimal)
Push button- reset - manual
brightness
Speed unitmps,kph,kt (mph - off)
Wind direction
Rotating switch- inst - 2 min - 10 min - brightness
- test - alr
Speed MIN / ChannelSpeed MAX
User Interface
8/11/2019 K045en97
4/14
K045en.ppt 1998-10
Frequency input for WAA151/251
6-bit parallel input for WAV151
Power supply (10.5-15.5 VDC)
Communication / Service line
4 analog inputs forWAT12, DAT12 and WMS300
Optional communicationinterface
I/O Interface
8/11/2019 K045en97
5/14
K045en.ppt 1998-10
Jumpers
X6
X11
X12X13X14
X8X10
111
11
WAT12 SUPPORT:X6, X11, X12 and X13SELECTS SHUNT RESISTORFOR CURRENT LOOP SIGNALS(INPUTS 19, 18, 17, 16)
WMS301/302 SUPPORT:X14 SELECTS PULL UPFOR SPEED(INPUT 13)
WAT12
WA151
WMS
WA151
Inverted
Non Inverted
OPTOISOLATED RS:X8 SELECTSPOLARITY(INPUT 6&7)
SERVICE LINE:X8 SELECTSPULL DOWN(INPUT 7)
Service
OFF
8/11/2019 K045en97
6/14
K045en.ppt 1998-10
Block Diagram
8/11/2019 K045en97
7/14
K045en.ppt 1998-10
Interfacing Sensors
WAA151
WAV151WMS301WMS302WAT12WAT11
- SD
S/D
+D D D D D- +
++
--
+ -
DDD
SS
SD S/DS/D S/D S/D S/D -
+
+++++
------
8/11/2019 K045en97
8/14
K045en.ppt 1998-10
WAV151WAA151
Power Supply(10.5 - 15.5 VDC)
WAC151
ZZ45048
Jumpers X6,11,12,13 must be disconnected!
I/O Interface
8/11/2019 K045en97
9/14
K045en.ppt 1998-10 Power Supply( ~ 15 VDC)
WAT12
Twisted pair with shield
WAA151 WAV151
Jumpers X6,11,12,13 must be connected!
4
I/O Interface
8/11/2019 K045en97
10/14
K045en.ppt 1998-10
Desktop Wall Ceiling Panel
144 mm
144 mm
Mounting
137 114
65
8/11/2019 K045en97
11/14
K045en.ppt 1998-10
User interface
Communication Calculation Message processing System control
RxD TxD GND
Configuration
8/11/2019 K045en97
12/14
K045en.ppt 1998-10
User Interface
Speed unit Speed resolution Brightness control Channel display Alarm display
Calculation ID Magnetic deviation ICAO Marked discontinuity Alarms Timeout Direction enable
Messages
WA151/251 WMS301 WAT12 WAT11/15 WAD21M
Configuration
Communication Baud rate Data bits Stop bits Parity Wires
8/11/2019 K045en97
13/14
K045en.ppt 1998-10
Set up the terminal program ... use time delay between each line
Send RESET... if not included in the file ... or reset the display
Send the *.CFG file to the display
Send OPEN... if not included in the file
Set up the terminal program
Send RESET... or reset the display
Send ..CFG commands to the display
Send OPEN
Configuration
On-line Configuration File Configuration
8/11/2019 K045en97
14/14
K045en.ppt 1998-10
Compatibility
WAA151
WAA251
WAV151
WMS301 WMS302
WAT12
QLI50
MILOS 500
QLC50WD20
WD30
WAT15
DMX501
WD30 only
w. WA151