2
Alarm display LED Cable Flow rate switch Integration switch Temperature switch Mode display LED Red............. Power supply Black .......... GND White......... Flow rate output Orange ..... Temperature output Yellow ....... Flow rate alarm Brown ....... Integration alarm Green ........ Temperature alarm Blue............ Integration reset Gray ........... COM (common alarm return) Water outlet Water inlet 130 (180) 56 28 28 32 (41) * The numerical values in parentheses are dimensions in KSL-160L specifications. 90 (110) (Unit: mm) 130 (180) 20 (35) 20 (35) Serial number 4-ø4.5 hole 57.5 (63) 16 (20.5) Body Front view Side view Plan view 33 6.5(8) 16 (20.5) Rc1/2 (Rc1) female thread, both sides Interface cable Karman Vortex System Flow Sensor KSL-80L/KSL-160L Digital display Setting switch Display panel SENSOR As a sensor for monitoring the cooling water of equipment, a cumulative total of 60,000 units have been delivered to leading semiconductor and LED equipment manufactures in the world. Measures and displays the flow rate, temperature, and integrated values. Analog output Alarm output The digital display is turned depending on the installation status. Digital display Features Electric wiring AWM20276: This is a cable with no terminal processing (9 core/0.2 mm 2 /1000 mm). GND should be used as a common ground wire for all other signaling lines including power supply. If COM is specified as the common alarm return in the order format, the return of the flow rate and temperature measurement alarm output is COM. Dimensions
Transcript
  • Alarm display LED

    Cable

    Flow rate switch

    Integration switch

    Temperature switch

    Mode display LED

    Red............. Power supplyBlack .......... GNDWhite......... Flow rate outputOrange ..... Temperature outputYellow ....... Flow rate alarmBrown ....... Integration alarmGreen ........ Temperature alarmBlue............ Integration resetGray ........... COM (common alarm return)

    Water outletWater inlet

    130(180)

    56

    2828

    32 (41)

    * The numerical values in parentheses are dimensions in KSL-160L specifications.

    90 (110)

    (Unit: mm)130 (180)

    20(35)

    20(35)

    Serial number4-ø4.5 hole

    57.5

    (63)

    16(2

    0.5)

    Body

    Front view

    Side view

    Plan view

    33

    6.5(

    8)

    16 (2

    0.5)

    Rc1/2 (Rc1) female thread,

    both sides

    Interface cable

    Karman Vortex System Flow Sensor KSL-80L/KSL-160L

    Digital display

    Setting switch

    Display panel

    SENSO

    R

    ● As a sensor for monitoring the cooling water of equipment, a cumulative total of 60,000 units have been delivered to leading semiconductor and LED equipment manufactures in the world.

    ● Measures and displays the �ow rate, temperature, andintegrated values.

    ● Analog output

    ● Alarm output

    ● The digital display is turned depending on the installationstatus.

    ● Digital display

    Features

    Electric wiring

    • AWM20276: This is a cable with no terminal processing (9 core/0.2 mm2/1000 mm).• GND should be used as a common ground wire for all other signaling lines including power supply.

    If COM is speci�ed as the common alarm return in the order format, the return of the �ow rate andtemperature measurement alarm output is COM.

    Dimensions

  • KSL 80L

    160L 24V

    12V A

    B

    Flow ratePowersupply

    Alarm

    Example KSL-80L-24V-V-A-B-A-COM

    DC12V

    DC24V

    Flow rate

    A

    B

    A

    B

    Note) The KSL-160L has the following accuracies:Accuracy of FS±2% in a range from 20 to 140 L/minAccuracy of FS±5% in a range from 140 to 150 L/minAccuracy of FS±10% in a range from 150 to 160 L/min

    Model

    Flow rate

    Integration

    Temperature detection range

    Output

    Alarm

    Maximum operating pressure

    Fluid temperature

    Ambient temperature

    Flow direction

    Power supply

    Current consumption

    Accuracy

    Material of body

    Materials of vibrator

    Applicable �uid

    Sealing O-ring

    Coupling of pipings

    Cable

    Weight

    KSL-160L

    20 to 160 L/min

    KSL-80L

    10 to 80 L/min

    Rc 1

    500g

    Rc 1/2

    380g

    0 to 999999 L

    0 to 99˚C

    0 to 10 V or 4 to 20 mA (�ow rate, temperature)/pulse (integration)

    MOS-FET ON or OFF (�ow rate, integration, temperature)

    1 MPa (below 10kgf/cm2)

    0 to 60˚C

    0 to 40˚C (Non-freezing)

    Speci�ed direction

    DC12V±5% or DC24V±10%

    30 mA max. (70 mA max. in 4 to 20 mA speci�cation)

    FS±2.0%

    SUS304

    Resin (LCP)

    Industrial water or service water

    Fluororubber

    AWM20276 9 cores/0.2 mm2/1000mm

    Integration

    Commonalarmreturn

    COM

    G

    Floatingstatus

    Connectedto GND

    * When the output of the �ow rate is set to "P" (pulse output), the temperature output is "V" or "I."In temperature output, the pulse output cannot be selected. (The order format of the output is "PV" or "PI.") Example: KSL-80L-24V-PV-A-B-A-COM

    * To improve the performance, the shape and speci�cations are subject to change without prior notice.

    Alarm

    Measurement valueA B

    Higher than the setting value

    Lower than the setting value

    Redlightout

    Redlightout

    Redlamp

    ON OFF

    Redlamp

    ONOFF

    De�nition of alarm output and display LED

    * The alarm output uses the common return for the �ow rate, integration, and temperature. For the common return, "COM: �oating status" or

    "G: Connected to GND" can be selected.

    The alarm is conductive when the MOS-FET is ON and non-conductive when it is OFF. The alarms for �ow rate, for integration, and for temperature can be set independently.

    2

    10 20 30 40 50 600

    5

    1011

    4

    12

    20

    0

    Volta

    ge o

    utpu

    t (V

    )

    Curr

    ent o

    utpu

    t (m

    A)

    Norm

    al tem

    perat

    ure

    KSL-80L

    KSL-160L

    90˚C

    70 80

    20 40 60 80 100 1200 140 160

    Flow rate (L/min)

    10 to 80L/min

    20 to 160L/min

    Output

    Flow rate Temperature

    V

    I

    P

    0 to 10V

    4 to 20mA

    Pulseoutput

    V

    I

    0 to 10V

    4 to 20mA

    SEN

    SOR

    Speci�cations Flow rate characteristics

    Caution:

    • The �ow rate characteristics are temperature dependent as shown in the above graph.

    To maintain accuracy, secure a straight-pipe length of 7D or more on the upstream side and 5D or more on the downstream side. Moreover, be sure to install valves, branches, gauges, etc. on the downstream side.(D: Diameter. For 80L, D = 13.5 mm; for 160L, D = 19.0 mm.)

    Order format

    Temperature

    KSL80-160-1_cs2KSL80-160-2_cs2


Recommended