+ All Categories
Home > Documents > Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad...

Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad...

Date post: 11-May-2020
Category:
Upload: others
View: 32 times
Download: 0 times
Share this document with a friend
15
Keypad User Manual 1 LCD/LED Keypad User Manual
Transcript
Page 1: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

1

LCD/LED Keypad

User Manual

Page 2: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

2

About this Manual

This Manual is applicable to LCD/LED keypad.

The Manual includes instructions for using and managing the product. Pictures, charts, images and all

other information hereinafter are for description and explanation only. The information contained in

the Manual is subject to change, without notice, due to firmware updates or other reasons. Please

find the latest version in the company website (http://overseas.hikvision.com/en/).

Please use this user manual under the guidance of professionals.

Legal Disclaimer

REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT

YOUR OWN RISKS. OUR COMPANY SHALL NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL

OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER

ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, OUR COMPANY WILL

PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.

SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR

JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE

APPLICABLE LAW. OUR COMPANY SHALL NOT BE LIABLE IN THE EVENT THAT THIS PRODUCT IS USED

WITH ILLEGITIMATE PURPOSES.

IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER

PREVAILS.

0100001050519

Page 3: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

3

Regulatory Information

FCC Information

FCC compliance: This equipment has been tested and found to comply with the limits for a digital

device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable

protection against harmful interference when the equipment is operated in a commercial environment.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used

in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case

the user will be required to correct the interference at his own expense.

FCC Conditions

This device complies with part 15 of the FCC Rules. Operation is subject to the following two

conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference received, including interference that may cause undesired

operation.

EU Conformity Statement

This product and - if applicable - the supplied accessories too are marked with "CE"

and comply therefore with the applicable harmonized European standards listed

under the EMC Directive 2004/108/EC, the RoHS Directive 2011/65/EU.

2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed

of as unsorted municipal waste in the European Union. For proper recycling, return

this product to your local supplier upon the purchase of equivalent new equipment,

or dispose of it at designated collection points. For more information see:

www.recyclethis.info.

2006/66/EC (battery directive): This product contains a battery that cannot be

disposed of as unsorted municipal waste in the European Union. See the product

documentation for specific battery information. The battery is marked with this

symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury

(Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For

more information see: www.recyclethis.info.

Industry Canada ICES-003 Compliance

This device meets the CAN ICES-3 (A)/NMB-3(A) standards requirements.

Page 4: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

4

Safety Instruction

These instructions are intended to ensure that the user can use the product correctly to avoid danger

or property loss.

The precaution measure is divided into ‘Warnings’ and ‘Cautions’:

Warnings: Serious injury or death may be caused if any of these warnings are neglected.

Cautions: Injury or equipment damage may be caused if any of these cautions are neglected.

Warnings Follow these safeguards to prevent

serious injury or death.

Cautions Follow these precautions to prevent

potential injury or material damage.

Warnings:

Please adopt the power adapter which can meet the safety extra low voltage (SELV) standard.

The power consumption cannot be less than the required value.

Do not connect several devices to one power adapter as an adapter overload may cause

over-heating and can be a fire hazard.

When the product is installed on a wall or ceiling, the device should be firmly fixed.

To reduce the risk of fire or electrical shock, do not expose the indoor used product to rain or

moisture.

This installation should be made by a qualified service person and should conform to all the local

codes.

Please install blackouts equipment into the power supply circuit for convenient supply

interruption.

If the product does not work properly, please contact your dealer or the nearest service center.

Never attempt to disassemble the product yourself. (We shall not assume any responsibility for

problems caused by unauthorized repair or maintenance.)

Please do not look directly into the laser light within 6 meters because laser is hazardous to

humans.

Page 5: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

5

Cautions:

Make sure the power supply voltage is correct before using the product.

Do not drop the product or subject it to physical shock. Do not install the product on vibratory

surface or places.

Do not expose it to high electromagnetic radiating environment.

Do not aim the lens at the strong light such as sun or incandescent lamp. The strong light can

cause fatal damage to the product.

The sensor may be burned out by a laser beam, so when any laser equipment is being used,

make sure that the surface of the sensor not be exposed to the laser beam.

For working temperature, please refer to the specification manual for details.

To avoid heat accumulation, good ventilation is required for a proper operating environment.

While shipping, the product should be packed in its original packing.

Please use the provided glove when open up the product cover. Do not touch the product cover

with fingers directly, because the acidic sweat of the fingers may erode the surface coating of the

product cover.

Please use a soft and dry cloth when clean inside and outside surfaces of the product cover. Do

not use alkaline detergents.

Improper use or replacement of the battery may result in hazard of explosion. Please use the

manufacturer recommended battery type.

Page 6: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

6

Content Chapter 1 Introduction _____________________________________ 7

1.1 Overview _______________________________________________ 7

1.2 Appearance Description ____________________________________ 7

1.3 Keypad Beeper and Indicator________________________________ 9

Chapter 2 Installation and Wiring ___________________________ 12

2.1 Wiring Connector Description ______________________________ 12

2.2 Keypad Address Settings __________________________________ 12

2.3 Keypad Installation _______________________________________ 13

2.4 Keypad Wiring __________________________________________ 14

Chapter 3 Keypad Alarm Operation Code _____________________ 15

Page 7: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

7

Chapter 1 Introduction

1.1 Overview

DS-PK00/PK00M/-LCD/LED series LCD/LED alarm keypad are used for connecting

to the security control panel. It implements operations on the security control panel through programming and prompts alarm with the indicators and audio

alert.

1.2 Appearance Description

No. Description

1 Keypad

2 LED/LCD Screen

3 Control Panel

4 Indicator Bar

Control Panel

Page 8: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

8

Button Description

Panic Button

Programming Button

Search Button

Bypass Button

Exit Button

Stay Arming Button

Away Arming Button

Indicator Bar

Button Description

Status Indicator

Operating Indicator

Power Indicator

Arming Indicator

Stay Arming Indicator

Page 9: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

9

1.3 Keypad Beeper and Indicator

The keypad registration will be completed in 10 seconds after the control panel

being power on. The system then will complete the start-up and enter the properly status of working in 20 seconds.

The beeper and indicator description after powering on are shown below.

Beeper Description

No. Sound Prompt Description

1 One Beep Pressing keys prompt; The command is timed out or the command is too long.

2 Two Beeps Valid command. Uploading the report

completed.

3 Five Beeps Invalid command. Failed to upload the report in 60s.

4 Continuous Beeping

For Two Seconds Fault Prompt

5 Slowly Continuous

Beeps Entry/Exit Delay

6 Rapidly Continuous Beeps

Entry/Exit Delay, less than 10s.

7 Rapid Beeps Zone Alarm; The keyboard is not registered.

8 Three Long Beeps and Two Short Beeps

The tampering prevention of the keyboard is turned on.

9 Three Beeps Registering the keyboard completed.

10 One Beep In Two Seconds

Two minutes before auto arming/disarming;

One minute before arming for temporary password.

11 Three Beeps In One Second

One minute before auto arming/disarming; 15s before arming for temporary password.

Page 10: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

10

Indicator Description

Status

Working Status Indicator Working Status Indicator

Normal Solid Green System Fault Solid Red

Power

Working Status Indicator

Power On Solid Green

Stay

Working Status Indicator Working Status Indicator

Partition Perimeter

Disarmed OFF

Partition System

Perimeter Armed Orange

Arm

Working Status Indicator Working Status Indicator

Partition Armed Solid Red Partition System

Disarmed Solid Green

Password Modifying Flicking Green Fob Code Matching Flicking Green

Testing Mode Solid Red Programming Flicking Green

OPERATING

Working Status Indicator Working Status Indicator

Normal Solid Green Programming Flicking Green

Password Modifying Flicking Green Fob Code Matching Flicking Green

Engineering Mode Solid Red System Fault Flicking Orange

Page 11: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

11

LED Zone Indicator

Zone

Working Status Indicator Working Status Indicator

Normal OFF Fault Solid Red

Alarm Flicking Red Bypass Solid Green

Zone Indicator under Engineering Mode (The corresponding zone indicator light will turn orange when operating):

No. Description No. Description

1 Off Hook 5 Sending CID Report

2 Dialing 6 Receiving Confirmation

3 Alarm Receiver Off

Hook 7 Control Panel On Hook

4 Receiving Handshake 8 Alarm Receiver On Hook

Zone Indicator under Status Mode (The corresponding indicator light will be solid

red if there is any fault):

No. Description No. Description

1 AC Current Interrupted 5 RS-485 Device

Disconnected

2 Low Voltage of Storage

Battery 6 Wired Network Exception

3 Movement Prevention of Control Panel Turning On

7 Wireless Network

Exception

4 Telephone Line

Disconnected 8 Reserved

Page 12: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

12

Chapter 2 Installation and Wiring

2.1 Wiring Connector Description

No. Description

1 Loud Speaker

2 Tamper-Proof Switch

3 Wiring Connector

4 DlP Switch

2.2 Keypad Address Settings

An address is required for each alarm keypad in the system. These addresses

cannot be repeated. Once exchanging the alarm keypad, the address of the new keypad must be the same as the replaced one. You should configure the address

via DIP switch of the keypad before powering on the system. The address should be in the range of 1~31.

When it is black on the end of ON as , indicated 1; when it is black on the other end as , indicated 0.

Page 13: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

13

1 2 3 4 5

0001 ■

02 ■

03 ■ ■

04 ■

05 ■ ■

06 ■ ■

07 ■ ■ ■

1 2 3 4 5

08 ■

09 ■ ■

10 ■ ■

11 ■ ■ ■

12 ■ ■

13 ■ ■ ■

14 ■ ■ ■

15 ■ ■ ■ ■

1 2 3 4 5

16 ■

17 ■ ■

18 ■ ■

19 ■ ■ ■

20 ■ ■

21 ■ ■ ■

22 ■ ■ ■

23 ■ ■ ■ ■

1 2 3 4 5

24 ■ ■

25 ■ ■ ■

26 ■ ■ ■

27 ■ ■ ■ ■

28 ■ ■ ■

29 ■ ■ ■ ■

30 ■ ■ ■ ■

31 ■ ■ ■ ■ ■

Keyboard Address ON DIP

Keyboard Address

Keyboard Address

Keyboard AddressON DIPON DIPON DIP

2.3 Keypad Installation

Before You Start: Make sure that the device in the package is in good condition and all the

assembly parts are included.

Make sure that the wall is strong enough to withstand three times the weight

of the keypad.

Set the keypad address before installation. Steps:

1. Route the cables through the cable

hole of the mounting plate.

2. Secure the mounting plate on the

wall with 4 supplied screws.

3. Connect the corresponding cables.

4. Push the keypad body in the mounting plate from bottom up.

5. Fasten the keypad body with the

three buckles on the plate.

Page 14: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

14

6. Align the screw holes with the

screws on the bottom of both keypad and mounting plate.

7. Tighten the screws to fix the keypad on the mounting plate and complete the installation.

2.4 Keypad Wiring

The keypad wiring is shown as follows.

It is recommended to use RVVP 2*0.5 with the maximum length of 1000m for

keypad wiring.

Page 15: Keypad User Manual - Hikvision · Keypad User Manual 9 1.3 Keypad Beeper and Indicator The keypad registration will be completed in 10 seconds after the control panel being power

Keypad User Manual

15

Chapter 3 Keypad Alarm Operation Code

Function Description Command

Programming/

Editing Password

Control Panel Programming 【Installer Password】【*】【0】【#】

Exit Operation 【*】【#】

Operator Password 【Operator Password】【*】【0】【#】

【User No. (3digits)】【#】

【New Password】【#】

【New Password】【#】

Testing Testing 【Password】【*】【6】【0】【#】

Alarm Center Testing 【Password】【*】【6】【1】【#】

Project Mode 【Password】【Project】【9】【0】【n】【#】

Exiting Project Mode 【Project】 or 【*】【#】

Arming/Disarming Normal(Away)Arming/Disarming 【Password】【#】

Instant Arming 【Password】【*】【7】【#】

Stay Arming 【Password】【*】【4】【#】

Clearing Alarm Clearing Under arming status 【*】【1】【#】

Bypass Bypass Zone(n) 【Password】【Bypass】【n】【n】【n】【#】

【Bypass】【n】【n】【n】【#】

nnn is the zone No.

Group Bypass 【Password】【*】【4】【1】【#】

Group Bypass 【Password】【*】【4】【2】【#】

Keypad Settings Enabling/Disabling Keypad Tone 【*】【5】【1】【#】

Enabling/Disabling Fault Prompt 【*】【5】【6】【#】

LCD Backlight Control 【*】【5】【2】【n】【n】【n】【#】

LCD Backlight Disabling 【*】【8】【#】