+ All Categories
Home > Documents > KRONOPLY OSB Complete Portfolio en 0611

KRONOPLY OSB Complete Portfolio en 0611

Date post: 22-Dec-2015
Category:
Upload: alin-tuvic
View: 18 times
Download: 5 times
Share this document with a friend
Description:
osb complete portfolio
Popular Tags:
42
Wood-Based Materials – Innovation & Respect for Nature Complete Portfolio KRONOPLY GmbH
Transcript
Page 1: KRONOPLY OSB Complete Portfolio en 0611

Wood-Based Materials – Innovation & Respect for Nature

Complete Portfolio

KRONOPLY GmbH

Page 2: KRONOPLY OSB Complete Portfolio en 0611

Contents

Page 3 ■ KRONOPLYOSB–HighTechMadefromNaturalWoodPage 4 ■ DeliveryProgrammePage 5 ■ DeliveryProgrammePage 6 ■ KRONOPLYOSB–HighTechMadefromNaturalWoodPage 7 ■ KRONOPLYOSB–TheOriginalforHealthyLivingPage 8 ■ KRONOPLYOSB–TheOptimumTeamPlayerPage 9 ■ KRONOPLYOSB–TheSustainableEnergy-StoringProductPage 10 ■ KRONOPLYOSB–EnergeticallyOptimisedConstructionsPage 11 ■ KRONOPLYOSB–TheInnovativeMultitalentPage 1� ■ Topics/Segments/ApplicationsPage 13 ■ Topics/Segments/ApplicationsPage 14 ■ Topics/Segments/ApplicationsPage 15 ■ Topics/Segments/ApplicationsPage 16 ■ TheKRONOFeel-GoodHousePage 17 ■ TheKRONOFeel-GoodHousePage 18 ■ KRONOPLYOSB/3,square-edge,ContiFinish®,CEPage 19 ■ TechnicalDataPage �0 ■ KRONOPLYOSB/3,T+G,sandedonbothsidesPage �1 ■ TechnicalDataPage �� ■ KRONOPLYOSB/3,T+G,ContiFinish®

Page �4 ■ KRONOPLYOSBSF-B,square-edgePage �5 ■ KRONOPLYOSBSF-B,T+GPage �6 ■ KRONOPLYOSB/F****,square-edgePage �7 ■ TechnicalDataPage �8 ■ KRONOPLYOSB/F****,T+G,ContiFinish®

Page �9 ■ TechnicalDataPage 30 ■ KRONOTECDP50,LiquiSafeT+GonallfouredgesPage 31 ■ TechnicalDataPage 3� ■ KRONOPLYOSB/4,sanded,MAGNUMBOARDrawboardPage 33 ■ TechnicalDataPage 34 ■ InformationonUsePage 35 ■ InformationonUsePage 36 ■ ProductOverviewPage 37 ■ ProductOverviewPage 38 ■ KRONO–Feel-GoodReferencesPage 39 ■ KRONO–Feel-GoodReferencesPage 41 ■ MoreServicefromUs,GreaterSuccessforYou

Page 3: KRONOPLY OSB Complete Portfolio en 0611

3

KRONOPLYOSB–HighTechMadeFromNaturalWood

KRONO – Strong with Wood-Based Materials TheSWISSKRONOGROUPisoneoftheworld’sleadingmakersofwood-basedmaterials.Wemakeawiderangeofproductsthatareallthe same in one respect: their quality is always fi rst-class.

Weareastrongfamily.Ourcommitted,hard-workingemployeesmakeenvironmentallysoundproductswhilesettingclearinternationalstandardsatourtenplantsinsevencountries,includingGermany,FranceandPoland.

Weoffercustomer-orientatedsolutionsinvolvinginnovative,eco-friendlyproductsaswellascomprehensiveconsultingandsupport.Inawarenessofourresponsibilitytosociety,weuseanaturalrawmaterial–wood–toproducecustom-tailoredwood-basedmaterials.

Innovation – Getting Better All the TimeDayafterday,weworkhardtomakeourproductportfolioevenmoreinnovative,morefunctionalandmoreconducivetohealthyliving.Onegoalweneverlosesightofisenvironmentalprotection.We’renaturallyalsobusiness-minded–butatthesametime,weattachgreatimportancetoreducingenvironmentalburdens.

Inconnectionwithallproductionprocessesandnewproducts,wecontinuallyaskourselves:“Couldthisbedoneevenbetter?”Andwearen’t satisfi ed until we get the best possible results and can say with goodreason:“Yes,housescanbeevenhealthiertolivein!”

KRONOPLY – Made in GermanyTheemployeesoftheSWISSKRONOGROUP’sGermanoperationhavedonepioneeringworktoadvanceenvironmentallyfriendlybuild-ingwithKRONOPLYOSB(OrientedStrandBoard).KRONOPLYGmbH,headquarteredinHeiligengrabe,producesKRONOPLYF****OSBboards that have even been certifi ed for use in food packaging.

Wood-BasedMaterials–Innovation&RespectforNature

KRONOPLYOSB–theinnovativewood-basedmaterial

Page 4: KRONOPLY OSB Complete Portfolio en 0611

4

DeliveryProgramme

Format [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40 Units/pallet

KRONOPLY OSB/3, square-edge 2500x1250 100 92 78 60 52 42 38 24ContiFinish® 2070x2770 78 60 52 42

2650x1250 78 60 52

2800x1250 78 60 52

3000x1250 78 60 52

5000x1250 36 30 26 22

5000x2500 20 16 14 12

KRONOPLY OSB/3, T + G 2500x675 T+Gonall4edges 60 52 48 38Sandedonbothsides

KRONOPLY OSB/3, T + G 2500x675 T+Gonall4edges 78 60 52 42 38ContiFinish® 2500x1250 T+Gonall4edges 78 60 52 42 38

KRONOPLY OSB SF-B, 2500x1250 60 52square-edge 3000x1250 78 60 52

KRONOPLY OSB SF-B, T + G 2500x1250**T+Gonall4edges 52

KRONOPLY OSB/F****, 2500x1250 78 60 52 42 38 32square-edge ContiFinish® 2650x1250 78 60

2800x1250 78 60 52

3000x1250 78 60

5000x2500 16 14 12 8

KRONOPLY OSB/F****, T + G 2500x675 T+Gonall4edges 60 52 42 38 32ContiFinish® 2500x1250T+Gonall4edges 78 60 52 42 38

6250x675 T+Gon2edges 22 18

KRONOPLY Kompaktholz, T + G 2050x675 T+Gonall4edges 78 60 52 42ContiFinish®

KRONOTEC DP50, T + G 2500x675 60 LiquiSafeonall4edges

KRONOPLY OSB/4 15000x2800 30pertruck

Sanded

MAGNUMBOARDrawboard

KRONOPLY OSB/Specialities

KRONOPLYOSB/3(longboards) 6501mmbis15000mm * * * *

KRONOPLYF****(longboards) 6501mmbis15000mm * * * *

Specialformatsonrequest

* Minimumorder:1loadperthicknessandformat** Soonalsoavailableinathicknessof22mm

Page 5: KRONOPLY OSB Complete Portfolio en 0611

5

Format [mm] Thickness [mm] 6 8 10 1� 16 18 19 �� �5 �8 30 Units/pallet

KRONOPLY MDF - raw 2800x2070 70 60 50 45 25 25 25 25 20 10 10E1 4100x2070 35 25 25 25 20

KRONOPLY MDF, melamined both sides 2800x2070 50 45 25 25 25 25 25 20 20WhitePaintingGradeP099

Specialformatsonrequest

Format [mm] Dicke in [mm] 9 18 �0 Units/pallet

KRONOPLY anti-termite, square-edge 2800x1196 100

KRONOPLY anti-termite, T + G 2400x675 52

KRONOPLY quicklyboard 2500x1250 46

Specialformatsonrequest

KRONOTHERM flex 1350x575 112 90 72 56 42 36 32 28 24 20 20 16

KRONOTHERM hardboard 170 1200x800 28 19 14 11 10

KRONOTHERM top 2500x580 100 60 40

KRONOTHERM indoor 1200x600 116 56 38 28

KRONOTHERM sound 800x675 440

Specialformatsonrequest

Format [mm] Thickness [mm] 9 18 �0 Units/pallet

Format [mm] Thickness [mm] 5 �0 �� 35 40 50 5� 60 80 100 1�0 140 160 180 �00 ��0 �40 Units/pallet

Page 6: KRONOPLY OSB Complete Portfolio en 0611

6

KRONOPLYOSB–HighTechMadefromNaturalWood

From Trees to a Modern Wood-Based MaterialKRONOPLYOSB(OSBstandsfor“orientedstrandboard”)isformedfrom long, slender strands or strips of wood (called flakes in the trade) which are layered in specific directions. It is a synthesis of a natural rawmaterialandinnovativetechnology.WemakeourKRONOPLYOSBboardsontheworld’smostadvancedsystemsforcontinuousproductionofwood-basedmaterials,usingonlyfreshthinningsfromsustainablymanagedforests. Three Layers – Maximum StabilityEveryKRONOPLYOSBproducthasthreelayers:twosurfacelayersand a core layer. In order to optimise the stability of the finished boards,thenaturalwoodstrandsofthecoverlayersarealignedinthe direction of production, which defines the principal orientation. Thestripsthatgointothetwo-plycorelayerrunperpendiculartotheorientationofthesurfacelayers.ThisapproachmaximisesthebendingstrengthofallKRONOPLYOSBproducts.

Did You Know? AtourproductionfacilityinHeiligengrabe,Germany,allproduc-tionwaste–suchassandingdustandleftoverwoodchips–isusedtofuelaspecialplantwhichgenerateselectricitythatisusedon-siteand/orsoldas“eco-power”.

Formaldehyde-Free BindersBefore being pressed at a high pressure and temperature, the flakes aremixedwithasmallamountofbinder.Thisconsistsofcompletelyformaldehyde-freebondingresins,thusensuringthatKRONOPLYOSBproductscontainonlytheformaldehydethatnaturallyoccursinthewood flakes. Conti-Roll Press for Top Quality Ourcutting-edgeConti-RollpressturnsoutKRONOPLYOSBproductsin a continuous process, which lets us guarantee first-class quality withimprovedthicknesstolerances.Theboardsurfacesarealsogivena high-quality finish: pressing causes the formation of a thin layer ofwoodandbondingresinswithwater-andmoisture-repellentpro-perties.WaterrollsrightoffthisContiFinish®surface,allowingtheboardstowithstandbriefexposuretomoisturewithoutharm.

Page 7: KRONOPLY OSB Complete Portfolio en 0611

7

KRONOPLYOSB–TheOriginalforHealthyLiving

OSB Expertise Since 1997TheSWISSKRONOGROUPblazednewtrailsin1997byusingtheworld’s fi rst Conti-Roll OSB system at KRONOPOL in Zary to produce storey-highformats.Sincethen,KRONOPLYhasbeenthemarketstandard.KRONOPLYOSBproductsaremanufacturedatourplantsinGermany,PolandandFrance.

Always Ahead of the CrowdKRONOPLYhasalongtraditionofdevelopinginnovativenewproducts.OnesuchinnovationistheproductionofapprovedKRONOPLYOSBboardswithalengthof15metres.Infact,theSWISSKRONOGROUPistheonlycompanyintheworldabletoproduce15-metre-longboards,havinginvestedinalong-boardstackingsystematitsHeili-gengrabeplant.

KRONOPLYOSB/3andKRONOPLYOSB/F****aremadeinlongversionswithboardlengthsbetween6.501and15metres.KRONOPLYOSB/4,therawboardusedfortheKRONOPLYMAGNUMBOARDbuild-ingsystem,isalsoproducedinalengthof15metres.

The latest KRONOPLY OSB innovation is the fl ame-resistant product KRONOPLY OSB SF-B, which meets the European fi re protection requirementsforpublicbuildings.

Buildersofprefabricatedhousesandotherstructurescantakeadvan-tageofthisKRONOPLYOSBinnovationtocreatelarge-sizewallandroofelements.Italsooffersproducersofprefabricatedelementsfortimber-frame houses many opportunities to increase effi ciency and tooptimisecosts.Plus,thelateststorey-highlongboardsfromtheKRONOPLYOSBproductfamilymakeitpossibleforasingleboard

toextendtheentirelengthofabuilding,completelyeliminatingbuttjoints.Thisdoesawaywiththeneedtolayplasterboardoverit.

Four Stars – Absolutely Food-SafeTheFoodProcessEngineeringsectionoftheInstituteofProcessEngineeringinLifeSciencesinKarlsruhe,Germanyhaspreparedanexpertisewhichshowsthatitisalsosuitableforpackagingfoods.Itiswellbelowthestrict0.03ppmemissionsceilingthatleadingGermanassociationsarecallingfor,asonlypinewoodandcompletelyform-aldehyde-freebindersareusedtoproduceit.ThisalsoensuresthatKRONOPLYOSB/F****isoptimallysuitedformodern,eco-friendlywoodconstructionandfurnitureproduction.

You’ll fi nd additional information at: www.kronoply.com

Page 8: KRONOPLY OSB Complete Portfolio en 0611

8

KRONOPLYOSB–AnOptimalTeamPlayer

Protection from Heat Whenitgetshotoutside,innovativeKRONOwood-basedmaterialsensureapleasantindoorclimate.Forexample,acombinationofKRONOTHERMfeel-goodinsulatingmaterialswithKRONOPLYOSBinroofsandwallsoptimallyshieldsbuildinginhabitantsfromthesummerheat.

Protection from ColdWhenthethermometerdropsbelowfreezinginwinter,roofandwallconstructionsthatincorporateKRONOTHERMfeel-goodinsulationandKRONOPLYOSBsavevaluableenergy.Airtightandwater-vapour-im-permeableKRONOPLYOSBsupplementsthehighinsulatingeffectofKRONOTHERMfeel-goodinsulatingmaterials.Combined,thesenaturalbuildingmaterialseffectivelyprotectlivingspacefromlowoutdoortemperatures.

Protection from NoiseWorking in tandem, KRONOPLY OSB and KRONOTHERM fi breboard insulatingmaterialseffectivelyblockoutsidenoise.Awidevarietyoftestedconstructionsisavailable.Theiroutstandingsound-absorbingpropertiesallowthemtoswallowexternalnoise–makingforamorerelaxinglife.

Protection from Moisture KRONOTHERMfeel-goodinsulatingmaterialsregulatethehumidityoftheairbyabsorbingexcessmoistureandreleasingitagainintotheindoorairasneeded.EveryproductoftheKRONOportfoliohasphysicalpropertiesthatareoptimisedforitsparticularapplications.

Thisenablesyoutocreatewater-vapour-permeableconstructionsthatdispensewithmembranesandvapourbarriers.

Protection from FireAn offi cially accredited institute has issued a general test certifi cate confi rming that KRONOPLY and KRONOTHERM products are suitable formakingcost-effective,water-vapour-permeablewalls.Exteriorwalls made with these products meet the requirements for a F30 fi re rating. Other constructions to meet fi re protection requirements can be implemented in compliance with DIN 4102-4. The fl ame-resistant KRONOPLY OSB SF-B version meets the European fi re protection requirementsforpublicbuildings.

Environmental Friendliness KRONOproductsaremainlymadefromthinningsfromsustainablymanaged forests. We have been certifi ed for these responsible practi-ces under the Pan European Forest Certifi cation (PEFC) scheme.

You’ll fi nd additional information at: www.kronoply.com

Applications

KRONOPLYOSBisamultifunctionalwood-basedmaterialthatlendsitselftoavastrangeofuses.Besidesapplicationsinpackaging,concreteformworkandprivacywalls,itismainlyusedintimber-framehousingconstructionsandforbuildinginteriors.InconjunctionwithKRONOTHERM fi breboard insulating materials, KRONOPLY OSB is an excellentsolutionforrealisingcost-effectiveconstructionsthatconformtoenergyconservationrequirementsandpassivehousestandards.

Use in Roofs KRONOPLYOSBisanidealload-bearingboardforroofs.Itsvapour-block-ingfunctionmaximisestheenergy-savingpotentialofKRONOTHERMfi breboard insulating materials. When using the water-vapour-permeable product KRONOTEC MDF (medium-density fi breboard) for the underroof panels,youcancreateroofswithouthavingtoresorttovapour-perme-ablemembranesorsealinglayers.Representingthestateoftheartintechnologyandcomplyingwithcurrentstandards,KRONOPLYmayalsobe used in fl at roof constructions. This lets you build large-area roofs muchfasterandsimplerthanwithboarding.

Use in Walls Inwallconstructionsintimber-framebuildings,KRONOPLYOSBexcelsbyservingasastiffening,vapour-inhibitingandairtightplane.Thestorey-high formats allow effi cient use with a minimum of cutting and trimming.

Use in CeilingsAlsoinceilingconstructions,combinationsofKRONOPLYOSBandKRONOTHERMoptimallyattenuatefootfallnoiseandinsulateagainstcold.

Page 9: KRONOPLY OSB Complete Portfolio en 0611

9

KRONOPLYOSB–TheSustainableEnergy-StoringProduct

Positive Environmental Balance SheetsInadditiontotheoutstandingconstructivepropertiesofKRONOPLYOSBproducts,theyalsoactivelycontributetoprotectingtheclimate.EachcubicmetreofKRONOPLYOSBstoresabout1000kgofCO2andkeepsitboundupduringtheentirelifetimeoftheproduct.ThepinewoodusedforenvironmentallygentleproductioncomesfromsustainablymanagedforestsintheGermanstatesofMecklenburg/Western Pomerania and Brandenburg, and most of it is PEFC-certifi ed.

Woodandwood-basedmaterialsaretheonlyload-bearingmaterialsthatcanbedescribedasenergy-conservingproducts,becausetheystoremoreenergythanittakestoproducethem.Inaddition,allKRONO wood-based materials are classifi ed as components with a negative“globalwarmingpotential”(GWP).Thestoredcarbonisnotreleasedduringtheentirelifetimeofthesecomponents.Andhistoryteachesusthatoptimallyplannedandbuiltstructuresconsistingofwoodandsustainablyproducedwood-basedmaterialscanlastforseveralcenturies.

Drive Without Guilt with KRONO

ThecalculationbelowshowshowusingKRONOproductscaneffec-tivelyminimiseyourpersonalcarbonemissionssoyou’llhaveaCO2budgetleftoverfordrivingyourcar.

Itcantakethefollowingamountsofwoodandwood-basedmaterialstobuildanaveragesingle-familyhouse:

Solidwoodandconstructiontimber: 10 cubicmetresKRONOPLYOSB: 12cubicmetresKRONOTECDP/WP50: 4cubicmetresKRONOTHERM fl ex: 70 cubic metres

Addedtogether,thismeansthatthehousewillstoreatotalof27,800kilosofCO2.Soifyouprotecttheenvironmentbybuildingit,inreturnyoucoulddriveaVWGolfBlueMotion,whichaccordingtoVolkswagenVWemits99gramsofCO2perkm,about280,800km.

You’ll fi nd additional information at: www.kronoply.com

Page 10: KRONOPLY OSB Complete Portfolio en 0611

10

KRONOPLYOSB–EnergeticallyOptimisedConstructions

Highly Specialised SystemsRoofsandexteriorwallsposeconsiderabledemandsintermsofstabil-ityandinsulation.Pitchedroofsinparticularareexposedtoweatherandtemperatureextremestoagreaterextentthananyotherpartofabuilding’soutershell.Optimallyinsulated,loadableconstructionscanonlybemadewithprofessionallyplannedandinstalled,harmo-nizedsystemcomponents.

KRONOoffersawiderangeofconstructiveandhighlyinsulatingwood-basedmaterialsthatareidealforcreatingenvironmentallyfriendly, effi cient solutions when erecting modern timber-frame housesormodernisingorextendingexistingbuildings.

Fire Protection with KRONOPLY OSBKRONOPLYOSBproductsalsomeetthespecialrequirementsformaterials used in fi re-resistant constructions. For example, in order to fulfi l the requirements for wood-based boards specifi ed by the EN13986standard,KRONOproducesitsKRONOPLYOSB/3withadensityofatleast600kg/cu.m.

You’ll fi nd loads of suggestions on our website for using KRONOPLY OSBandotherKRONOwood-basedmaterialstobuild,renovateoraddanextrastoreytohouses.Therearealsopracticalexamplestakenfromactualprojects,includingdetailedexplanationsandillustrations.

Checkitoutatwww.kronoply.com.

You’ll fi nd additional information at: www.kronoply.com

Builtby:HolzbauKühlbornGmbH,34286SpangenbergPhotograph: Wiedemann Fotografi e, 34117 Kassel

Page 11: KRONOPLY OSB Complete Portfolio en 0611

11

KRONOPLYOSB–TheInnovativeMultitalent

Save Money with Energy-ConservingRenovationInmanycountries,thebiggestpotentialforsavingenergycanberealisedwhenrenovatingoldbuildings.Specialtechniquessuchasinfraredphotographycanpreciselyrevealhowheatisdistributedovera building’s exterior. They make it easy to identify insuffi cient insulation andthermalbridges.ProfessionallyplannedandexecutedbuildingrenovationprojectsusingreliableKRONOPLYOSBproductsandKRONOTHERM fi breboard insulating materials as harmonised parts of acoordinatedsystemincreasethevalueofproperties,enhancethewellbeingoftheirresidentsandreduceheatingcosts.

InmanycountriesincludingCanada,theUnitedStatesandtheUK,governmentgrantsareavailabletohelphomeownersrenovate–especially if the improvements increase energy effi ciency. Find out howyoucangetassistanceforreducingenergyconsumptionandreleasinglessclimate-damagingcarbondioxide.

Give It Secure, Eco-Friendly PackagingIfyouchooseKRONOPLYOSBasyourpackagingmaterial,you’llbeprotectingbothyourproductsandtheenvironment.KRONOPLYOSBmeetsthedemandingrequirementsofthepackagingindustrywithitsexcellenttechnicalattributes,andoureco-friendlyKRONOPLYOSB/F**** is a certifi ed high-tech product that is suitable in every respectforpackagingfood.

KRONOPLY OSB even meets with fl ying colours the strict import rules thatsomecountries,forexampleChina,haveforwoodenpackaging:duringproductionofitontheConti-Rollsystemwithpressingtem-peraturesofaround200°C,anyinsectsorgermsinthewoodarereliablykilled.

Did You Know?Anexamplecalculationillustratestherealisticallyachievablesavings and environmental benefi ts. Interior roof insulation with KRONOTHERMandKRONOPLYOSB:theannualsavingcaneasilyamounttoabout180kWhpersquaremetre.Thatisequivalentto13litresofheatingoil,18cu.mofnaturalgasor40kgofwoodpersquaremetre. You’ll fi nd additional information at: www.kronoply.com

Page 12: KRONOPLY OSB Complete Portfolio en 0611

1�

Topics/Segments/Applications

Sustainable Roof Renovation Themostimportantpartofahouseisitsroof.Itisextremelyexposed to fluctuating temperatures and the weather. If it is inade-quatelyinsulated,thespacebeneathitisheatedupgreatlyduringthesummer,andinthewinterheatingcostsincrease.Usingsustainablematerialstorenovatetheroofcreatesmodern,healthylivingspace.

Eco-Friendly Systems Involving Wood-Based MaterialsInordertoachievethebestpossibleresults,thematerialsusedmustbehighlyinsulatingwhilealsomeetingotherrequirementssuch as airtightness, wind tightness and fire protection. Challenges are posed by extreme fluctuations in temperature and relative humidity.KRONOPLYandKRONOTHERMareeco-friendlywood-basedmaterialsthatarespeciallydesignedtodealwiththem.Usedasasystem, they regulate the natural fluctuations between cold and heat andbetweendrynessandmoisture.ByusingKRONOPLYOSBfortheload-bearingconstructionincombinationwithwater-vapour-permeableKRONOTHERMfeel-goodinsulatingmaterials,youcancreatelivingspacewithahighfeel-goodfactor.

Did You Know? KRONOPLYOSBhasanenvironmentalproductdeclaration(EPD)inaccordancewithISO14025,issuedbytheInstituteConstruc-tionandEnvironmente.V.AnEPDevaluatesaproduct’sentirelifecycleaccordingtointernationalstandardstoestablishabasisforsustainableconstruction.

Page 13: KRONOPLY OSB Complete Portfolio en 0611

13

Topics/Segments/Applications

Gaining Space by Adding Another Storey Whenthereisnoroomlefttolaterallyexpand,forexampleincrampedinnercities,orwhenthereisawishtoavoidencroachingonthegarden,itisstillpossibletogainextralivingspace.Thesolutionistoaddanotherstorey.Justhoweasy,fastandcleanlythiscanbedoneisshownbythephotographsofaKRONOreferenceprojectonthispage.

In2009theGottfriedfamilyinRöslau,Germanydecidedtoaddanotherstoreytoanannextheyhadalreadybuiltontotheirsingle-familyhouse.Theyalsowantedtotakeadvantageoftheopportunitytorenovate.Itwasimportanttothemtocompletetheprojectquicklyandwithoutlettingtheconstructionworkintroduceanydampintotheexistingbuilding.Theychoseasystemconsistingofwood-basedmaterialsfromKRONO.

A Consistently Pleasant Indoor Climate“Wemadetherightdecision,”saystheGottfriedfamilynow.“Inbothwinterandsummerwenowenjoyaveryagreeable,constantindoorclimate.”Thisfeel-goodclimatewasimplementedwithKRONOPLYOSB,whichlendstheconstructionahighdegreeofstabilitywithoutaddingmuchadditionalweight.

Roof Insulation Without Loss of SpaceTheGottfriedfamilydecidedtoinsulatetheroofwithKRONOTHERMfl ex and water-vapour-permeable KRONOTEC DP50, which avoided any loss of space on the top fl oor. Another advantage of this insulation systemisthattheindoorroomsarenotneededfortheinstallationwork–thuseliminatingtheannoyanceofhavingtomoveorremovefurnitureetc.Allofthematerialsarebroughtupandalloftheworkisdoneoutside,andthehighinherentstiffnessofKRONOTHERMfl ex makes it even easier to install as roof insulation. These benefi ts convinced the Gottfried family, who are now completely satisfi ed with the quickly achieved fi nal results of their “KRONO project”.

You’ll fi nd additional information at: www.kronoply.com

Page 14: KRONOPLY OSB Complete Portfolio en 0611

14

Topics/Segments/Applications

Construction Without Thermal Bridges Athermalbridgeisabuildingpartthroughwhichheatcanescapeto the outside signifi cantly faster than via other parts. Lower temper-aturesresultlocallyontheinsideoftheaffectedcomponent.Thiscoolingeffectincreasesenergyconsumptionandcausesmoistureproblemssuchascondensationorevenmould.Eventuallyitresultsindamagetothebuilding.However,theseriskscanbeavoidedwithprofessionallyplannedinsulationandtheuseofcoordinatedmaterialsinthecontextofasystem.

Intelligent, Flexible SolutionsToensureenergy-conserving,hygienicallysoundconstructions,theymustbeintelligentlyplannedandbuilt.KRONOoffersalargenumberof fl exible solutions for new houses, renovation projects, and adding anextrastorey.Forexample,itistypicallynotallowedtoinstallexteriorinsulationonoldbuildingswithprotectedstatus.Theonlyalternativeinsuchcasesistoinsulatethewallsontheinside,whichposesconsiderablethermal,acousticalandventilationchallenges.

Alsoinrenovationprojects,whichcallforspecialsolutions,asystemconsistingofKRONOTHERMinsulatingmaterialsandload-bearinglayers of KRONOPLY OSB let you create modern, energy-effi cient feel-goodhouses.

Thermography:Athermalbridge-thereisan“energyleak”here.

AKRONOsystemsolution:exteriorwallonexteriorwall–joinedwithoutthermalbridges.

Did You Know?Infraredthermography,alsoknownasthermalimaging,revealstheenergeticweakpointsandthermalbridgesinabuilding’soutershell.Itisthenobviouswherethereisaneedforrenova-tion.Picturestakenwithspecialinfraredcameraspreciselyshowwhich parts of a building are losing signifi cant amounts of heat.

Builtby:HolzbauKühlbornGmbH,34286SpangenbergPhotograph: Wiedemann Fotografi e, 34117 Kassel

KRONOTHERM top 35 mm

KVH 60/180 mm

KRONOTHERM fl ex

KRONOPLY OSB 1� mm

Plasterboard 1�.5 mm

= –0.040 W m·K

Page 15: KRONOPLY OSB Complete Portfolio en 0611

15

Topics/Segments/Applications

Flat Roofs – Economical ConstructionsFlatroofsareroofconstructionsthatarehorizontalororhavealowpitch.Theentiresurfaceareaistypicallycoveredwithawaterproofmembrane.Moderntimber-framehousesallowtheinstallationofeconomical fl at roof constructions that are largely prefabricated and lie on rafters spaced far apart. Predestined for use in many fl at roofs areKRONOPLYOSB/3andKRONOPLYF****.KRONOPLYproductsletyoucreatedurableconstructionsthatalsomeetthermal,acousticalandventilationrequirements.

Fast to Lay and No ChemicalsKRONOPLY OSB/3 and KRONOPLY F**** fulfi l the requirements of variousstandardsowingtotheirmoisture-resistantPMDIbinders.Outstandingresultshavebeenobtainedwiththesematerialsinalarge number of fl at roof constructions. In contrast to the wood-based materials ordinarily used in fl at roofs, KRONOPLY OSB/3 and KRO-NOPLYF****donotrequireanychemicaltreatment.Anotheradvan-tageisthatKRONOPLYOSBismuchfastertolaythanroofboarding.If you use it together with eco-friendly KRONOTHERM fl ex fi breboard insulation,youcancountonaverygoodmoisturebarrier.

Did You Know?Becausetheyaremadewithformaldehyde-freePMDIbinders,KRONOPLYOSB/3andKRONOPLYF****complywidelywiththerequirements for use in fl at roofs. In Germany, for example, they are allowed by Holzbau Deutschland – Bund Deutscher Zimmer-meister and the German Plumbers’ Association (ZVSHK).

You’ll fi nd additional information at: www.kronoply.com

Builtby:Bema,69483Wald-Michelbach

Page 16: KRONOPLY OSB Complete Portfolio en 0611

16

TheKRONOFeel-GoodHouse

1

�3

4

5

6

7

9

10

111�

13

14

15

10

Contemporary, Energy-Effi cient and DurableThe solution to future challenges for modern, energy-effi cient con-structionandrenovationissimple:highlyspecialised,coordinatedproductsystemsfromKRONOPLYthatmakeforoptimallyinsulated,architecturallyattractivefeel-goodhouses.

EverysingleproductintheKRONOfeel-goodprogrammeexcelswithoutstandingstability,insulatingperformanceandeco-friendliness.AKRONOPLYroofsystemalonecanpareupto30percentoffyourheatingcosts.Atthesametime,thecarbonstoredinthewood–anatural,renewablerawmaterial–makesanactivecontributiontoprotectingtheenvironment.

AllKRONOPLYsystemmodulesareintelligentlydesigneddowntothetiniestdetailandhaveproventhemselvesinpractice.Thankstohighlevelofprefabricationoftheroof,wallandceilingelements,ittakesonlybetweenoneandthreedaystoassemblearain-tightKRONOfeel-goodhouse.Theexclusiveuseofeco-friendlywood-basedmater-ialseliminatesdryingphaseswiththecostlywaitstheyentail.

ThevariousKRONOPLYsystemmodulesarefreelycombinableandalso suitable for meeting special requirements such as fi re protection. AselectionofourintelligentKRONOPLYsystemmodulesisshownontheright.

You’ll fi nd more system variants, information on installation and de-taileddataonourKRONOPLYsystemproductsatwww.kronoply.com.

8

Page 17: KRONOPLY OSB Complete Portfolio en 0611

17

13 KRONOPLY system for on rafters insulation

Components from the inside out ■ Rafters,visible■ 18mmofKRONOPLYOSB■ 180 mm of KRONOTHERM flex■ 15mmofKRONOTECDP50■ Counterbattens/battens■ U-value:0.20W/m2K■ Phaseshift:10.2hours■ Heatretention:92%

14 KRONOPLY interior wall system Fire protection:

■ 9.5mmofplasterboard■ 15mmofKRONOPLYOSB■ 80mmofStuds/KRONOTHERMflex■ 15mmofKRONOPLYOSB■ 9.5mmofplasterboard■ F30-Bacc.toDIN4102-4,table50

1� KRONOPLY system for exterior walls with F30 fire protection:

Components from the inside out ■ 9.5mmofplasterboard■ 12mmofKRONOPLYOSB/3orKRONOPLYF****■ 200 mm of KRONOTHERM flex / Studs (min. of 160mm)■ 15mmofKRONOTECWPorDP50■ U-value:0,21W/m²K■ Phaseshift:11hours■ Heatretention:94%■ Alternatively,therecanbe12.5mmofplasterboard ontheinsideanda60mminstallationlayer, insulated with KRONOTHERM flex.■ F30-Bacc.toAbPP-3014/7701-MPABS

Various KRONO system products were used in

the KRONO feel-good house shown on the left:

1 KRONOTHERM flex� KRONOTHERMsound3 KRONOTHERMhardboard1704 KRONOPLYOSB/3T+G,sandedonbothsides5 KRONOPLYOSB/F****,square-edgeContiFinish®6 KRONOPLYOSB/F****,T+GContiFinish®7 KRONOTECDP508 KRONOTHERMtop9 KRONOPLYquicklyboard10 KRONOTEX laminate

15 KRONOPLY Ceiling System

Components from the inside out ■ KRONOTEX laminate flooring■ 5mmofKRONOTHERMsound■ 18mmofKRONOPLYOSB■ 60mmofKRONOTHERMhardboard170■ 22mmofKRONOPLYOSB■ 200mmofrafters■ Between them, 160 mm KRONOTHERM flex■ 18mmofKRONOPLYOSB■ 9.5mmofplasterboard

11 KRONOPLY system for between rafters insulation

Components from the inside out ■ 12.5mmofGKFgypsumfireboard■ 18mmofKRONOPLYOSB■ 180mmofrafters/KRONOTHERMflex■ 35mmofKRONOTHERMtop■ Counterbattens/battens■ U-value:0.20W/m2K■ Phaseshift:12.0hours■ Heatretention:96%■ F30-Bacc.toDIN4102-4, table66

Page 18: KRONOPLY OSB Complete Portfolio en 0611

18

KRONOPLYOSB/3,square-edgeContiFinish®,monitoredbyHFBENGINEERINGGMBH,madewithformaldehyde-freebinders,CE,PEFC

The High-Performance Classic All-RounderForload-bearingandstiffeningapplications,theidealwood-basedmaterial is KRONOPLY OSB/3, CE-certifi ed according to EN 13986 and producedincompliancewithEN300.FeaturingaContiFinish®surface,thissturdyboardisalsoexcellentlysuitedforload-bearingusesinkitchens,bathroomsandlaundryrooms.

High Strength and ContiFinish® SurfaceDesignedtowithstandnormalstresses,KRONOPLYOSB/3isoutstand-ingvalueformoney.Producedexclusivelywithformaldehyde-freebinders,theserobustboardscontainonlytheformaldehydethatisboundupinnaturalwood.Consequently,theirformaldehydeemis-sionsnotonlycomplywiththestipulationsoftheE1guideline,butarealso signifi cantly less than the much stricter ceiling of 0.03 ppm called forbyvariousassociations(e.g.BDF,AKÖHandRALinGermany).KRONOPLYOSB/3boardsarealsousedaseco-friendlywood-basedmaterialsinpackagingandfurniture.

Applications ■ Interiorandexteriorwallboardingwithastiffeningeffect■ Load-bearingceilingboarding■ Roofboarding(insteadofrawtimber)■ Wallcladding■ Floors■ Packaging■ Shelves■ Furniture■ Doors

Did You Know?KRONOPLYOSB/3correspondstoEuropeanutilisationclasses1+2inaccordancewithEN1995-1-1andisthereforesuitableformoistroomsandexteriorusesifnotexposedtotheweather.

Modernarchitecturalhighlights:implementedwithKRONOwood-basedmaterials

You’ll fi nd additional information at: www.kronoply.com

Page 19: KRONOPLY OSB Complete Portfolio en 0611

19

Technical Data Characteristicvaluesacc.toEN13986

Strand direction Major axis Minor axisNominal board thicknesses [mm] d 6-10 >10-18 >18-�5 6-10 >10-18 >18-�5

Note:Thecharacteristicvaluesareforstructuralcalculationsacc.toEC5andDIN1052:2008-12.

Strength values [N/mm�]Stresses on board

Bending fm,k 18.0 16.4 14.8 9.0 8.2 7.4

Compression fc,90,k 10.0 10.0

Shear fv,k 1.0 1.0

Plate loading

Bending fm,k 9.9 9.4 9.0 7.2 7.0 6.8

Tensileforce ft,k 9.9 9.4 9.0 7.2 7.0 6.8

Compression fc,k 15.9 15.4 14.8 12.9 12.7 12.4

Shear fv,k 6.8 6.8

Stiffness values [N/mm�] Stresses on board

Bendingmodulusofelasticity Emeana 4930 1980

Shearmodulus Gmeana 50 50

Plate loading

Modulusofelasticity Emeana 3800 3000

Shearmodulus Gmeana 1080 1080

aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.85xEmeanandG05=0.85xEmean

General and building physics values

Bulkdensityacc.toEN323 m 600kg/m3

Max.deviationsinboardthickness ±0.8mm(unsanded)|±0.4mm(sanded)

Tensilestrengthperpendiculartoplaneacc.toEN319 perm.σZy 0.18 0.15 0.13 0.18 0.15 0.13

Thermalconductivityacc.toEN13986 λ 0.13W/mK

Watervapourpermeabilityvalue μ 200/300

Thickness swelling acc. to EN 317 ≤ 15 %

Emissionsclass E1–100%formaldehyde-freebinders

Utilisationclassesacc.toENV1995-1-1 1+2

Reaction to fire performance class acc. to EN 13501-1 B-s2, D0

CE certificate no. 1034 – CPD – 1291 / 1 / 09

EN 13986

Delivery Programme and Product Overview

Format [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x1250 • • • • • • • •

2070x2770 • • • •

2650x1250 • • •

2800x1250 • • •

3000x1250 • • •

5000x1250 • • • •

5000x2500 • • • •

Page 20: KRONOPLY OSB Complete Portfolio en 0611

�0

KRONOPLYOSB/3,T+GSandedonbothsides,madewithformaldehyde-freebinders,CE,PEFC

Naturally Stable with Tongue-and-Groove Joints KRONOPLY OSB/3 T + G is sanded on both sides, CE-certifi ed under EN13986andproducedincompliancewithEN300.Allfouredgesareprofi led for tongue-and-groove joints, making it excellently suited for seamlesslaying.

Ideal for Direct CoatingBeingsandedonbothsides,KRONOPLYOSB/3T+Gcanbecoatedjustlikenormalwood.Varnishes,oils,waxesandglazesofallkindsshouldbeappliedinmultiplecoats(asarule,atleastthree).Inter-mediate sanding after applying the fi rst coat improves the fi nal result.

ThegoodtechnicalpropertiesandseamlesssurfaceofKRONOPLYOSB/3T+Gmakeitexcellentlysuitedforrenovationandforbuildingnew, eco-friendly houses. The precisely fi tting tongue-and-groove systemmakesitquickandeasytolaydirectlyonraftersoroverfootfallnoiseinsulation.

Applications ■ Floorrenovation■ Dryandscreedfloors■ Rooforfloorboardingwithastiffeningeffect■ Walls,closetsandstairs■ Decorativeuses

Did You Know?Theboardscanbeworkedwithordinary,commerciallyavailabletoolssuchasportablepowersaws,althoughcarbide-tippedblades are recommended. They can be affi xed using staples, nailsorscrews.

Quickandeasylaying,alsoforlargesurfaces:KRONOPLYOSB/3,T+G

Builtby:HolzbauKühlbornGmbH,34286SpangenbergPhotograph: Wiedemann Fotografi e, 34117 Kassel

Page 21: KRONOPLY OSB Complete Portfolio en 0611

�1

KRONOPLYOSB/3,T+GSandedonbothsides,madewithformaldehyde-freebinders,CE,PEFC

Delivery Programme and Product Overview

Format [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x675T+Gonall4edges • • • •

Technical Data Characteristicvaluesacc.toEN13986

Strand direction Major axis Minor axisNominal board thicknesses [mm] d >10-18 >18-�5 >10-18 >18-�5

Note:Thecharacteristicvaluesareforstructuralcalculationsacc.toEC5andDIN1052:2008-12.

Strength values [N/mm�]Stresses on board

Bending fm,k 16.4 14.8 8.2 7.4

Compression fc,90,k 10.0 10.0

Shear fv,k 1.0 1.0

Plate loading

Bending fm,k 9.4 9.0 7.0 6.8

Tensileforce ft,k 9.4 9.0 7.0 6.8

Compression fc,k 15.4 14.8 12.7 12.4

Shear fv,k 6.8 6.8

Stiffness values [N/mm�] Stresses on board

Bendingmodulusofelasticity Emeana 4930 1980

Shearmodulus Gmeana 50 50

Plate loading

Modulusofelasticity Emeana 3800 3000

Shearmodulus Gmeana 1080 1080

aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.85xEmeanandG05=0.85xEmean

General and building physics values

Bulkdensityacc.toEN323 m 600kg/m3

Max.deviationsinboardthickness ±0.8mm(unsanded)|±0.4mm(sanded)

Tensilestrengthperpendiculartoplaneacc.toEN319 perm.σZy 0.15 0.13 0.15 0.13

Thermalconductivityacc.toEN13986 λ 0.13W/mK

Watervapourpermeabilityvalue μ 200/300

Thickness swelling acc. to EN 317 ≤ 15 %

Emissionsclass E1–100%formaldehyde-freebinders

Utilisationclassesacc.toENV1995-1-1 1+2

Reaction to fire performance class acc. to EN 13501-1 B-s2, D0

CE certificate no. 1034 – CPD – 1291 / 1 / 09

EN 13986

Page 22: KRONOPLY OSB Complete Portfolio en 0611

KRONOPLYOSB/3,T+GContiFinish®,madewithformaldehyde-freebinders,CE,PEFC

��

Did You Know? EN13986“Wood-basedpanelsforuseinconstruction”nowhastheforceoflaw.Itisnolongernecessarytoapplyforapermit.

Quick to Lay, with a Stiffening EffectWithitswater-andmoisture-repellentContiFinish®surface,KRONOPLY OSB/3, T + G is specifically designed for use in moist roomssuchaskitchens,bathroomsandlaundryrooms.ItisCE-certified under EN 13986 and produced in accordance with EN 300. All four edges are profiled for tongue-and-groove joints, making this boardextremelyversatile.Bending Resistance for StabilityKRONOPLYOSB/3,T+Gexcelsinawiderangeofapplicationsduetoitshighstrength.Despiteitsrelativelylowweight,itachievesbendingresistancevaluescomparabletothoseofplywood.Itshigh-qualityContiFinish®surfacerepelswater.

Becauseitinhibitswatervapourdiffusion,whenusingthismaterialforboardingtheinsideofexteriorwallsintimber-framehousesthereisnoneedtosealwithawater-vapour-impermeablemembrane.

Applications ■ Floorrenovation/dryfloors/underdryscreed■ Stiffeninginteriorwallboarding■ Roofpanelling(insteadofrawtimber)■ Forreinforcingheavilystressedroofs (applicationclass2asperEN1995-1-1)■ Asbearingceilingboards|interiorconstructions/decorativeuses

Delivery Programme and Product OverviewFormat [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x675T+Gonall4edges • • • • •

2500x1250T+Gonall4edges • • • • •

Technical Data Characteristicvaluesacc.toEN13986

Strand direction Major axis Minor axisNominal board thicknesses [mm] d >10-18 >18-�5 >10-18 >18-�5

Note:Thecharacteristicvaluesareforstructuralcalculationsacc.toEC5andDIN1052:2008-12.

Strength values [N/mm�]Stresses on board

Bending fm,k 16.4 14.8 8.2 7.4Compression fc,90,k 10.0 10.0Shear fv,k 1.0 1.0Plate loadingBending fm,k 9.4 9.0 7.0 6.8Tensileforce ft,k 9.4 9.0 7.0 6.8Compression fc,k 15.4 14.8 12.7 12.4Shear fv,k 6.8 6.8Stiffness values [N/mm�] Stresses on boardBendingmodulusofelasticity Emean

a 4930 1980Shearmodulus Gmean

a 50 50Plate loadingModulusofelasticity Emean

a 3800 3000Shearmodulus Gmean

a 1080 1080aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.85xEmeanandG05=0.85xEmean

General and building physics valuesBulkdensityacc.toEN323 m 600kg/m3

Max.deviationsinboardthickness ±0.8mm(unsanded)|±0.4mm(sanded)Tensilestrengthperpendiculartoplaneacc.toEN319 perm.σZy 0.15 0.13 0.15 0.13Thermalconductivityacc.toEN13986 λ 0.13W/mKWatervapourpermeabilityvalueμ 200/300Thickness swelling acc. to EN 317 ≤ 15 %Emissionsclass E1–100%formaldehyde-freebindersUtilisationclassesacc.toENV1995-1-1 1+2Reaction to fire performance class acc. to EN 13501-1 B-s2, D0CE certificate no. 1034 – CPD – 1291 / 1 / 09

EN 13986

Page 23: KRONOPLY OSB Complete Portfolio en 0611

�3

Builtby:TerhalleObjektbauBauträgerGmbH,48683Ahaus-OttensteinPhotograph:MenseFotodesign,44139Dortmund

Page 24: KRONOPLY OSB Complete Portfolio en 0611

KRONOPLYOSBSF-B,square-edge,CEFlame-resistant

The Board with Built-in Fire ProtectionWiththenewKRONOPLYOSBSF-B,theSWISSKRONOGROUPhasonceagaindemonstratedistforward-looking,innovativeexpertisein wood-based materials. This flame-resistant OSB version has been tested by a certified institute in Germany and assigned to the B-s2, d0 reaction-to-fire performance Euroclass for flame-resistant building elements.Innovative Production Technology In order to comply with the latest and strictest European fire re-sistancerequirements,theSWISSKRONOGROUPhasdevelopedaninnovative technology for producing flame-resistant OSB boards.

ApplicationsThe new KRONOPLY OSB SF-B meets the fire protection requirements forpublicbuildingssuchasschools,hospitals,kindergartensandsportsfacilitiesandalsoforcommercial,residentialandtradefairstructures.

■ Wallandceilingcladding■ Timber-frameconstructionandwoodpanelling

Delivery Programme and Product OverviewFormat [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x1250 • • 3000x1250 • • •

�4

Did You Know? Euroclass B-s2, d0 means that a board is flame-resistant (B) and releasesamoderateamountofsmoke(s2)whenburning,butwithoutanydrippingfromtheburningboard(d0).

Note:Thecharacteristicvaluesareforstructuralcalculationsacc.toEC5andDIN1052:2008-12.

Strength values [N/mm�]Stresses on board

Bending fm,k 16.4 8.2 Compression fc,90,k 10.0 10.0Shear fv,k 1.0 1.0Plate loadingBending fm,k 9.4 7.0Tensileforce ft,k 9.4 7.0Compression fc,k 15.4 12.7 Shear fv,k 6.8 6.8Stiffness values [N/mm�]Stresses on boardBendingmodulusofelasticity Emean

a 4930 1980Shearmodulus Gmean

a 50 50Plate loadingModulusofelasticity Emean

a 3800 3000Shearmodulus Gmean

a 1080 1080aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.85xEmeanandG05=0.85xEmean

General and building physics valuesBulkdensityacc.toEN323 m 600kg/m3

Max.deviationsinboardthickness ±0.8mm(unsanded)Tensilestrengthperpendiculartoplaneacc.toEN319 perm.σZy 0.15 0.15Thermalconductivityacc.toEN13986 λ 0.13W/mKWater vapour permeability coefficient μ 200/300Thickness swelling acc. to EN 317 ≤ 15 %Emissionsclass E1–100%formaldehyde-freebindersUtilisationclassesacc.toENV1995-1-1 1+2Reaction to fire performance class acc. to EN 13501-1 B-s2, D0

Technical Data Characteristicvaluesacc.toEN13986

Strand direction Major axis Minor axisNominal board thicknesses [mm] d 1�-18 1�-18

NEW

DIN EN 13501-1

EN 13986: 2004 | 1034 – CPD – 1899/1/2010

Page 25: KRONOPLY OSB Complete Portfolio en 0611

KRONOPLYOSBSF-B,T+G,CEFlame-resistant

�5

Dimensionally Stable Safety and ReliabilityApart from providing outstanding protection from fire risks, KRONOPLYOSBSF-B,T+Gscorespointsbecauseallfouredgesare profiled for tongue-and-groove joints, which enables fast, easy installation.Integrated Fire ProtectionWhen the causes of fires are analysed, in most cases they turn out to besomethingminorandactuallyharmless.Itisonlywhentheyquik-kly spread to ready flammable building materials that, for example, aburningwastebasketcanturnintoaburninghouse.Numeroustestseries have shown that KRONOPLY OSB SF-B does not catch fire even

when it is continuouslly exposed to flame. Instead, its surface chars, forming a safely fireproof layer. KRONOPLY OSB SF-B thus comes with built-in fire protection. Applications(FireprotectionrequirementslikeKRONOPLYOSBSF-B,square-edge)

■ Wallandceilingcladding■ Timber-frameconstructionandwoodpanelling■ Ceilings / floors

Delivery Programme and Product OverviewFormat [mm] Thickness [mm] 18

2500x1250*T+Gonall4edges •

Did You Know? Fire protection also safegards the environment: every fire releasestoxicgasessuchasdioxins,hydrogencyanide,nitrogenoxides etc. The use of flame-resistant building materials there-forecontributestoprotectingtheenvironment.

Note:Thecharacteristicvaluesareforstructuralcalculationsacc.toEC5andDIN1052:2008-12.

Strength values [N/mm�]Stresses on board

Bending fm,k 16.4 8.2 Compression fc,90,k 10.0 10.0Shear fv,k 1.0 1.0Plate loadingBending fm,k 9.4 7.0Tensileforce ft,k 9.4 7.0Compression fc,k 15.4 12.7 Shear fv,k 6.8 6.8Stiffness values [N/mm�] Stresses on boardBendingmodulusofelasticity Emean

a 4930 1980Shearmodulus Gmean

a 50 50Plate loadingModulusofelasticity Emean

a 3800 3000Shearmodulus Gmean

a 1080 1080aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.85xEmeanandG05=0.85xEmean

General and building physics valuesBulkdensityacc.toEN323 m 600kg/m3

Max.deviationsinboardthickness ±0.8mm(unsanded)Tensilestrengthperpendiculartoplaneacc.toEN319 perm.σZy 0.15 0.15Thermalconductivityacc.toEN13986 λ 0.13W/mKWatervapourpermeabilityvalue μ 200/300Thickness swelling acc. to EN 317 ≤ 15 %Emissionsclass E1–100%formaldehyde-freebindersUtilisationclassesacc.toENV1995-1-1 1+2Reaction to fire performance class acc. to EN 13501-1 B - s2, D0

Technical Data Characteristicvaluesacc.toEN13986

Strand direction Major axis Minor axisNominal board thicknesses [mm] d 1�-18 1�-18

NEW

DIN EN 13501-1

EN 13986: 2004 | 1034 – CPD – 1899/1/2010

*Soonalsoavailableinathicknessof22mm

Page 26: KRONOPLY OSB Complete Portfolio en 0611

�6

Complete SecuritySimplyourbest:KRONOPLYOSB/F****(”Ffourstars“),Conti-Finish®, German technical approval Z-9.1- 618, monitored by HFB ENGINEERINGGMBH,conformstoCEEN13986(OSB/4).ItisasstrongasMAGNUMBOARD,whichismadefromit,andabsolutelyconducivetohealthyliving,asitismadewithcompletelyformalde-hyde-freebinders.Itsprincipalapplicationisineco-friendlytimber-frameconstruction.

The Eco-Friendly Wood-Based Material of the FutureAsoneoftheworld’sleadingproducersofenvironmentallyfriendlywood-basedmaterials,werelyentirelyonnaturalrawmaterials.Thatmeansusingwoodfromthemaintenanceandthinningofsustainablymanagedforeststomakeourpremiumproduct:KRONOPLYOSB/F****.ItsformaldehydeemissionsarenotonlybelowtheE1ceilingof0.1ppm,butareevenconsiderablylowerthanthestrictermaximumof0.03ppmthatotherorganisationsarecallingfor.Asaresult,itisevensuitableforpackagingfood.Whenitisusedintransportortopackagesensitivefoods,theContFinish®surfaceeffectivelykeepsoutmoistureanddamp.

Applications ■ Wood-frameandengineeredwoodconstruction■ Constructionforindustry/commercialhousingconstruction■ Shopsandtradefairstands(fordecorativeuses)■ Tradefairstands/concreteformwork/prefabricatedhouses■ Asload-bearingceilingboards■ Floorssubjecttoheavyfoottraffic■ Forreinforcingheavilyloadedwalls■ Packaging

KRONOPLYOSB/F****,square-edgeContiFinish®, German technical approval Z-9.1-618, monitored by HFBENGINEERINGGMBH,madewithformaldehyde-freebinders,CE,PEFC

Did You Know?Withcutting-edgeproductionequipment,itispossibletomakeboardsupto15metreslong.Usedtobuildhomesandindustrystructures,theselongboardsspeedconstructionwork.

You’ll fi nd additional information at: www.kronoply.com

Page 27: KRONOPLY OSB Complete Portfolio en 0611

�7

Strength values [N/mm�]Stresses on board

Bending fm,k 28.0 23.0 23.0 14,0 12.5 12.5

Shear fv,k 1.5 1.5

Plate loading

Bending fm,k 19.5 17.0 17.0 13.5 12.5 12.5

Tensileforce ft,k 12.0 10.5 10.5 8.0 7.5 7.5

Compression fc,k 14.0 12.5 12.5 11,0 10.5 10.5

Shear fv,k 8.0 7.0 7.0 8.0 7.0 7.0

Stiffness values [N/mm�] Stresses on board

Bendingmodulusofelasticity Em,meana 6500 3000

Shearmodulus Gmeana 100 100

Plate loading

Bendingmodulusofelasticity Em,meana 3500 2500

Tensilemodulusofelasticity Et,meana 3500 2500

Bulkmodulusofelasticity Ec,meana 3500 2500

Shearmodulus Gmeana 1000 1000

aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.9xEmeanandG05=0.9xEmean

General and building physics values

Bulkdensityacc.toEN323 m 620kg/m3

Max.deviationsinboardthickness ±0.4mm

Embedmentstrength permσ I 5.0 4.0

Tensilestrengthperpendiculartoplaneacc.toEN1087-1 σZy 0.14 0.12 0.10 0.14 0.12 0.10

Thermalconductivityacc.toDINEN13986 λ 0.13W/mK

Watervapourpermeabilityvalue μ 200/300

Thickness swelling acc. to EN 317 ≤ 9 %

Emissionsclass E1–100%formaldehyde-freebinders<0.03ppm

Utilisationclassesacc.toENV1995-1-1 1+2

Reaction to fire performance class acc. to EN 13501-1 D - s2, D0

Applicable German technical approval Z-9.1-618

Technical Data

Strand direction Major axis Minor axisNominal board thicknesses [mm] d 8-≤18 >18-≤25 >25-30 8-≤18 >18-≤25 >25-30

Delivery Programme and Product Overview

Format [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x1250 • • • • • •

2650x1250 • •

2800x1250 • • •

3000x1250 • •

5000x2500 • • • •

EN 13986

Page 28: KRONOPLY OSB Complete Portfolio en 0611

�8

KRONOPLYOSB/F****,T+GContiFinish®, German technical approval Z-9.1-618, CE, PEFC

Make Roofs for Extreme Stresses FastWithtongue-and-groovejointsontwoorfoursides,KRONOPLYOSB/F****(”Ffourstars“)–T+G,ContiFinish®,Germantechnicalap-proval Z-9.1- 618, monitored by HFB ENGINEERING GMBH, conforms toCEEN13986(OSB/4)–ensuresrapidprogressinbuildingyourroof.Especiallyforapplicationsthatcallforhighstrengthanddimensionalstability,thisconstructive,eco-friendlywood-basedmaterialistherightchoice.

Outstanding Environmental Properties and Structural StrengthWithitsexcellenttechnicalpropertiesandmadeusingonlyformalde-hyde-freebinders,KRONOPLYOSB/F****isthemodernall-round-er.Wheneverthereareconsiderableexpectationswithregardtostructuralstrength,buildingphysicsandhealthyliving,theprosgoforKRONOPLYOSB/F****.Thisdiffusion-inhibitingmaterialisapprovedforstiffeninginteriorandexteriorwalls,ceilingsandroofs,amongstotheruses.

Applications ■ Wood-frameandengineeredwoodconstruction■ Constructionforindustry/commercialhousingconstruction■ Shopsandtradefairstands(fordecorativeuses)■ Tradefairstands/concreteformwork/prefabricatedhouses■ Asload-bearingceilingboards■ Floorssubjecttoheavyfoottraffic■ Roofpanelling(insteadofrawtimber)■ Forreinforcingheavilystressedroofs(application2asper EN1995-1-1)

Did You Know?You’ll fi nd data sheets and dimensional tables for the entire KRONOPLYOSBrangeasPDFsforfreedownloadingatwww.kronoply.com.

Builtby:TerhalleObjektbauBauträgerGmbH,48683Ahaus-OttensteinPhotograph:MenseFotodesign,44139Dortmund

Page 29: KRONOPLY OSB Complete Portfolio en 0611

�9

Delivery Programme and Product Overview

Format [mm] Thickness [mm] 9 10 1� 15 18 �� �5 30 40

2500x675 T+Gonall4edges • • • • •

2500x1250T+Gonall4edges • • • • •

6250x675 T+Gonall4edges • •

Strength values [N/mm�]Stresses on board

Bending fm,k 28.0 23.0 23.0 14.0 12.5 12.5

Shear fv,k 1.5 1.5

Plate loading

Bending fm,k 19.5 17.0 17.0 13.5 12.5 12.5

Tensileforce ft,k 12.0 10.5 10.5 8.0 7.5 7.5

Compression fc,k 14.0 12.5 12.5 11.0 10.5 10.5

Shear fv,k 8.0 7.0 7.0 8.0 7.0 7.0

Stiffness values [N/mm�] Stresses on board

Bendingmodulusofelasticity Em,meana 6500 3000

Shearmodulus Gmeana 100 100

Plate loading

Bendingmodulusofelasticity Em,meana 3500 2500

Tensilemodulusofelasticity Et,meana 3500 2500

Bulkmodulusofelasticity Ec,meana 3500 2500

Shearmodulus Gmeana 1000 1000

aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.9xEmeanandG05=0.9xEmean

General and building physics values

Bulkdensityacc.toEN323 m 620kg/m3

Max.deviationsinboardthickness ±0.4mm

Embedmentstrength permσ I 5.0 4.0

Tensilestrengthperpendiculartoplaneacc.toEN1087-1 σZy 0.14 0.12 0.10 0.14 0.12 0.10

Thermalconductivityacc.toDINEN13986 λ 0.13W/mK

Watervapourpermeabilityvalue μ 200/300

Thickness swelling acc. to EN 317 ≤ 9 %

Emissionsclass E1–100%formaldehyde-freebinders<0.03ppm

Utilisationclassesacc.toENV1995-1-1 1+2

Reaction to fire performance class acc. to EN 13501-1 D - s2, D0

Applicable German technical approval Z-9.1-618

Technical Data Characteristicvalues

Strand direction Major axis Minor axisNominal board thicknesses [mm] d 8-≤18 >18-≤25 >25-30 8-≤18 >18-≤25 >25-30

EN 13986

Page 30: KRONOPLY OSB Complete Portfolio en 0611

30

KRONOTECDP50LiquiSafe,T+Gonall4edges,Germantechnicalapproval9.1-442,CE,PEFC

The Multifunctional Underroof BoardKRONOTECDP50withLiquiSafe,T+Gonallfouredgesiswater-vapour-permeable MDF (medium-density fi breboard) for use asunderroofpanelling.Withabulkdensityofabout500kg/cu.m,KRONOTECDP50isveryeasytoworkand,withathicknessof15mm,highlyloadable.

LiquiSafe Protects the Building FrameAtroofpitchesofjust15°ormore,theapplication-friendlyLiquiSafetongue-and-groovesystemiswatertight,thusprotectingthebuildingframe.Thiseliminatestheneedforadditionalboardingandawater-vapour-permeablemembraneormultiplepliesofbitumentokeepoutrainwater.KRONOTECDP50performsallofthesefunctionsandisalsofastertolaythanindividualboards.Whendry,theboardsarepuncture-resistantuptoarafterspacingofonemetre.

Applications ■ Underroofpanelling(classUDP-AasdefinedbytheGermanRoofing Association)■ Outerboardingforwallsoftimber-framehouses

Did You Know?KRONOTECDP50hasbeenapprovedbythestateDeutschesInstitutfürBautechnikinBerlinforstiffeningapplications.

You’ll fi nd additional information at: www.kronoply.com

Page 31: KRONOPLY OSB Complete Portfolio en 0611

31

Technical Data Characteristic values acc. to Z-9.1-442

Nominal board thicknesses [mm] d 1�-15

Strength values [N/mm�]Stresses on board

Bending fm,k 17.0

Shear fv,k 8.0

Plate loading

Bending fm,k 14.0

Tensileforce ft,k 9.5

Compression fc,k 7.5

Shear fv,k 5.5

Stiffness values [N/mm�] Stresses on board

Modulusofelasticity Em,meana 2700

Shearmodulus Gmeana 50

Plate loading

Bendingmodulusofelasticity Em,meana 1300

Tensilemodulusofelasticity Et,meana 1300

Bulkmodulusofelasticity Ec,meana 1300

Shearmodulus Gmeana 600

aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.9xEmeanandG05=0.9xEmean

General and building physics values

Bulkdensityacc.toEN323 m 510-550kg/m3

Max.deviationsinboardthickness ±0.5mm

Embedmentstrength fh,k 18.0N/mm

Thermalconductivity λ 0.09W/mK

Watervapourpermeabilityvalue μ 11

Thickness swelling acc. to EN 317 ≤ 6.5 %

Emissionsclass E1–100%formaldehydefreebinders

Utilisationclassesacc.toENV1995-1-1 1+2

Flammabilityclass B2-normalcombustibility

Applicable German technical approval Z-9.1-442

The values given in DIN 1052:2008-12, tables F.1 und F.2, for the board type “fibreboards as per MBH.LA2 DIN EN 622-3:2004-07” must be used as the modification coefficients kmod and deformation coefficients kdef.

TheshearmodulusKsermustbedeterminedusingtableG.1ofDIN1052:2008-12,lines4and5.Thebulkdensityofthematerialshouldbeassumedtobeρk=510kg/cu.m.

Delivery Programme and Product Overview

Format [mm] Thickness [mm] 15

2500x675 •

EN 622-5

Page 32: KRONOPLY OSB Complete Portfolio en 0611

3�

The Fast, Innovative Building SystemKRONOPLYMAGNUMBOARDisasolidbuildingsystemapprovedbytheGermanbuildingauthorities.Itconsistsofseveral25-mm-thickKRONOPLYOSB/4boardsgluedtogether.TheKRONOPLYOSB/4usedto make it is a wood-based material that is certifi ed as safe for food applications,freeofformaldehyde-containingbindersandextremelyresistanttopests.ItismadeentirelyfromthinningsfrommanagedGermanforests.Onlycompletelyformaldehyde-freebindersareusedtoachievehighlystablebondingoftherawmaterials.KRONOPLYOSB/4isproducedinasizeof15x2.8metreswithathicknessof25mmandsandedsurfaces.ThisinnovativeKRONOPLYOSBproductisoptimallysuitedformakinglargewallandroofelementsforprefabricatedandbuilthouses.Itoffersproducersofprefabri-catedcomponentsfortimber-framehousesmanyopportunitiestowork more effi ciently and optimise costs. Storey-high long boards oftheKRONOPLYOSBproductfamilycancovertheentirelengthofbuildings,thusresultinginconstructionsthatarefreeofbuttjoints.Itisthennolongernecessarytoaddplasterboard,anditiseasytodirectlycoverthemwithwallpaper,plasterortiles.

Dimensionally Stable and Certifi edKRONOPLYMAGNUMBOARD,likeKRONOPLYOSB/4,isextremelydimensionallystable,structurallyverystrong,andexcellentlysuitedfor thermal and acoustic insulation and fi re protection. Planned aperturesforstairways,windowsanddoors,electricalconduitsandsanitaryandheatinginstallationsarecutoutandpreciselymilledtotherequiredsizeandshapepriortogluing.Thisconsiderablyreducesthesubsequentlyrequiredwork.Theboardsarepressedtothick-nesses from 75 to 250 mm with between three and ten plies. The fi nal sizesarefreelyselectable.

Interior Coating – Everything Is PossibleKRONOPLYMAGNUMBOARDelementshaveasandedsurfacethatcan be directly painted, papered, smoothed with fi ller, plastered or fi nished with a veneer, laminate, etc. Depending on the stresses theywillbesubjectedto,theycanalsobeoptionallycoveredwithplasterboard.

Did You Know?EveryelementoftheKRONOPLYMAGNUMBOARDwoodbuildingsystem is covered by technical approval no. Z-9.1-591 of the stateDeutschesInstitutfürBautechnikinBerlin.

You’ll fi nd additional information at: www.kronoply.com

KRONOPLYOSB/4,sandedGerman technical approval Z-9.1-503, CE, PEFC, MAGNUM BOARD raw board

Page 33: KRONOPLY OSB Complete Portfolio en 0611

33

Format [mm] Thickness [mm] �5

15000x2800 •

Strength values [N/mm�]Stresses on board

Bending fm,k 27.5 19.0

Shear fv,k 1.5 1.5

Plate loading

Bending fm,k 10.9 8.0

Tensileforce ft,k 11.5 11.0

Compression fc,k 14.5 14.5

Shear fv,k 7.0 7.0

Stiffness values [N/mm�] Stresses on board

Bendingmodulusofelasticity Em,mean 7500 3500

Shearmodulus Gmean 70 90

Plate loading

Tensilemodulusofelasticity Et,mean 3500 3000

Bulkmodulusofelasticity Ec,mean 3500 2500

Shearmodulus Gmean 1100 1100aThecharacteristicstiffnessvaluesE05andG05arecalculatedasfollows:E05=0.9xEmeanandG05=0.9xEmean

General and building physics values

Bulkdensityacc.toEN323 m 620kg/m3

Max.deviationsinboardthickness ±0.8mm ±0.8mm

Embedmentstrengthacc.toEN1087-1 σZy 0.13 0.13

Thermalconductivityacc.toEN13986 λ 0.13W/mK

Watervapourpermeabilityvalue μ 200/300

Changeinlengthwhenrel.humidityincreases/decreases %/% 0.005

Thickness swelling acc. to EN 317 ≤ 8 % ≤ 8 %

Emissionsclass E1–100%formaldehyde-freebinders<0.03ppm

Reaction to fire performance class acc. to EN V 1995-1-1 1 + 2

FlammabilityclasstoEN13501-1 B-s2,D0

Applicable German technical approval Z-9.1-503

Technical Data Characteristicvalues

Strand direction Major axis Minor axisNominal board thickness [mm] d �5 �5

EN 13986

Page 34: KRONOPLY OSB Complete Portfolio en 0611

34

InformationonUse

Storage■ Protect boards from exposure to signifi cant moisture or very high relativehumidity.

■ Prevent direct contact of the boards with the fl oor.

■ Onlystoreoutdoorstemporarily,andifunavoidablecoverstacks withwatertightbutwater-vapour-permeabletarpaulins.

■ Alwaysstackboardshorizontallyonpalletsandwoodensupports (spacednomorethan600mmapart).

■ Alignwoodensupportspreciselywithoneanotherandparallelto theshortersideoftheboards.

■ Laytheboardssotheiredgeslineup(withamaximumoverhang of15mm).

Sawing, Milling, Sanding and Drilling■ KRONOPLYOSBcanbesanded,sawn,milledanddrilledjustlike solidwoodandusingallofthesametools.

Transport and Handling■ Takestepstopreventtheboards,andespeciallytheunprotected edges,fromabsorbinglargeamountsofmoistureduringtransport andinstallation.Becarefulnottodamagetheedgeswhenlifting, movingandstackingboards(thisappliesespeciallytotongue-and- grooveboards).

■ Checkagainstthelabelsorproducer’sdocumentationon-siteto makesurethatthefollowingarecorrect:thickness,approved utilisationclass,surface(sandedorContiFinish®)andedgetype (square-edgedortongue-and-groove).

■ During installation, boards may be briefl y leaned against a solid structureata70°angle.

■ Alwayscarryindividualboardsinanupright(vertical)position.

Acclimatisation■ Preconditionboardspriortoinstallation.

■ Storeboardsforaboutthreedaysunderthesameclimatic conditionsthatprevailattheinstallationsite.

■ Thisadjustmenttotheambientmoistureattheinstallationsite willpreventexcessiveshrinkageorswelling.

Builtby:HolzbauKühlbornGmbH,34286SpangenbergPhotograph: Wiedemann Fotografi e, 34117 Kassel

Page 35: KRONOPLY OSB Complete Portfolio en 0611

35

Laying and Boarding■ Forinteriororexteriorboardingapplications,leaveexpansionjoints atleast3mmwidebetweenboards.

■ Whenlaidcloselywithbuttjointsininteriorwalls,leaveroomfor expansionwheretheboardsadjoinotherstructures.

■ Thestorey-highformatsareproducedwithaslightlyreducedwidth (of1247mm)toallowforexpansion.

Nailing, Stapling, Screwing and Gluing■ KRONOPLYOSBcanbeattachedtowoodenstudsandraftersusing screws,nailsorstaples.

■ Use in accordance with the offi cial approvals and standards (Z-9.1-618, Z-9.1-503 and DIN 1052 in Germany as well as EN1995-1-1(EC5)).

■ Additionallybondorgluetongue-and-groovejoints.

You’ll fi nd additional information at: www.kronoply.com

Coating and Varnishing■ KRONOPLYOSBwithaContiFinish®surfacemaybecoatedwith asolvent-containingPU(DD)orsynthetic-resinvarnish.

■ Sandedsurfacesmaybecoatedlikenormalwood(e.g.with varnishes,paints,oils,waxesandglazes).

■ Itisadvisabletoapplyatleastthreecoats,sandingafterthe fi rst one.

■ Applicationofatleastthreecoatsisrecommended.

■ Theonlywaytoachieveanabsolutelysmoothsurfaceisto apply fi ller.

Builtby:HolzbauKühlbornGmbH,34286SpangenbergPhotograph: Wiedemann Fotografi e, 34117 Kassel

Page 36: KRONOPLY OSB Complete Portfolio en 0611

36

ProductOverview

KRONOPLY SpecialTheKRONOPLYSpecialserieswithoutstandingtechnicalpropertiesisforapplicationsunderspecialconditions,forexampleinpartsoftheworldwheretermitesareendemicandatconstructionsites.

KRONOPLY anti-termite, square-edge

■ Termite-resistantOSBquality

■ Foruseintermite-infestedareas

■ Completelyimpregnatedandlastinglyeffective

KRONOPLY anti-termite, T+G

■ Termite-resistantOSBquality,edgedforversatiletongue-and- groovejoints

■ For wooden constructions for export to afflicted regions

■ Completelyimpregnatedandlastinglyeffective

KRONOPLY quicklyboard

■ Aversatileformworkboardforfacilitatingconcretingwork

■ Superbbendingproperties

■ ContiFinish®surfacepreventspenetrationofmoisture

KRONOPLY MDFMadeentirelyoutofdebarkedpineandsprucewood,KRONOPLYMDF(medium-density fibreboard) excels with consistently high-quality fibre and a light colour. This is a versatile, high-quality product for all applicationsforwhichsolidwoodandotherwood-basedmaterialsareinadequateorunsuitable.

KRONOPLY MDF - raw E1

■ Bulkdensityofabout690-810kg/cu.m,idealforvarnishing, painting,coating,veneering,laminatingandsheathing

■ Aclassicmaterialforfurnitureandthefullrangeofinterior applications(stairs,shelves,doors,etc.),forshopsandtrade fairstands

■ Excellentlysuitedfordrilling,milling,etc.

KRONOPLY MDF - melamined both sides WhitePaintingGradeP099

■ CombinestheadvantagesofrawKRONOPLYMDFwiththe ruggednessofaplasticcoating

■ Idealforinteriorapplications,restaurantandkitchencabinets, laboratoryinstallationsandbuildingmobilehomes

KRONOPLY MDF raw

KRONOPLY anti-termite, square-edge

KRONOPLY MDF coated on both sides

KRONOPLY anti-termite, T + G

KRONOPLY quicklyboard

EN 13986

Page 37: KRONOPLY OSB Complete Portfolio en 0611

37

The KRONOTHERM Feel-Good ProgrammeKRONOTHERMfeel-goodinsulatingmaterialsmadefromnaturalwoodfi bre turn roofs, ceilings, fl oors, interior and exterior walls, and wall infi lls into energetically optimised components.

KRONOTHERM fl ex

■ Flexible infi ll insulation for roofs, ceiling and walls

■ Highlyinsulatingandwater-vapour-permeable

■ Protectsagainstheat,coldandnoise

■ Createsanexcellentindoorclimate

KRONOTHERM hardboard 170

■ Compression-resistantinsulationforroofs,ceilingandwalls

■ ComplieswithEN13171andGermantechnicalapproval Z-23.15-1581

■ Optimalthermalstorageforprotectionfromsummerheat

■ Highlywater-vapour-permeable

KRONOTHERM top

■ Insulatingboardforroofsandwalls

■ Compression-resistantandthermallyinsulating

■ Protectsagainstheat,cold,moistureandnoise

■ Reducesthermalbridges

KRONOTHERM fl ex KRONOTHERM hardboard 170

KRONOTHERM top KRONOTHERM sound

KRONOTHERM indoor

KRONOTHERM indoor

■ Insulationforinteriorwalls

■ For improving the energy effi ciency of exterior walls, especially inoldbuildingswithprotectedstatus

■ Acost-effectivealternativetofaçadeinsulation

■ Canbecoveredwithlimeorearthenplaster

KRONOTHERM sound

■ Floorboardforreducingfootfallsound

■ Can be used under all hardwood and laminate fl oors

■ Compression-resistant,elastic,optimisesacoustics

■ Pleasantlyshiftsfrequencyoffootfallsoundforacousticwellbeing

Did You Know?TheproductionofKRONOTHERMfeel-goodinsulatingmaterialsisrigorouslymonitoredbothbyusandbyanexternalinstitute.EveryKRONOTHERMproductismadeonstate-of-the-artequipment and is CE-certifi ed in compliance with EN 13171 and German technical approval no. Z-23.15-1581.

You’ll fi nd more information at: www.kronoply.com

Page 38: KRONOPLY OSB Complete Portfolio en 0611

38

KRONOFeel-GoodReferences

A New House Built with KRONO – Environmentally Friendly Living Space for Children

Thisprojectfocusedonhealthconsiderations.Inordertopreventenvironmentaltoxinsorsolventsfromposinghealthhazardstosmallchildren,topprioritywasgiventousingoptimallyinstalled,natur-almaterials.

Tomakethiseco-friendlywoodenhouse,theplan-nersoptedforKRONOPLYOSBandKRONOTHERMfi breboard insulation.

Thissingle-storeydetachedhousewasextendedupwardswithaKRONOsysteminvolvingwood-basedmaterialstocreateatwo-storeyKRONOfeel-goodhouse.

Topreventtheexpandedlivingspacefromincurringsignifi cantly greater heating costs, the work was donewitheco-friendly,highlyinsulatingKRONOproducts.Forthisreferenceproject,acombinationof KRONOPLY MAGNUM BOARD, KRONOTHERM fl ex andKRONOTHERMhardboardwaschosen.

Adding a Storey with KRONO – More Room for Feeling Good

BeforeAfter Before After

You’ll fi nd additional information at: www.kronoply.com

Builtby:Bema,69483Wald-Michelbach

Page 39: KRONOPLY OSB Complete Portfolio en 0611

39

Renovation with KRONO – for a Constant Feel-GoodClimate

Construction of a New House with KRONO – Architectural Solutions for the Future

Inthisproject,theownersofasingle-familydetachedhousewantedtomakefastprogresswhilepreventingtheworkfromintroducinganydampintothebuilding.

Theprojectwascarriedoutwiththeeco-friendlyKRONOPLYMAGNUMBOARDwoodbuildingsys-tem.Andthehouse’sresidentswerethrilledwiththeresults!Thankstothehighinsulatingeffectofthe KRONOTHERM fibreboard insulation used, it is pleasantlycoolinthesummer–evenrightundertheroof–andtheheatingcostsinthewintertimearelow.

Asthisexampleshows,itispossibletobuildarchitec-turallyambitioushousesoutofwood.Thiscube-shapedbuildingischaracterisedbybothmodernityandfunctionality.

Contemporarywoodenhouseslikethisonesportaflat roof and cost-effective constructions. Many of its componentsareprefabricated,andraftersandstudsarespacedwellapart.ThankstoKRONOPLYOSB/3andKRONOPLY F****, which are approved for use in flat roofswithoutanychemicaltreatment,itsinhabitantsenjoy a feel-good climate, even beneath a flat roof.

BeforeAfter Before After

Page 40: KRONOPLY OSB Complete Portfolio en 0611

40

Builtby:Bema,69483Wald-Michelbach

Page 41: KRONOPLY OSB Complete Portfolio en 0611

41

MoreServicefromUs,GreaterSuccessforYou

Telephone HotlineRingourServiceHotlinetogetadviceandtipsonallproducts,issuesandinstallationmethods.YoucanreachourexpertsfromMondaytoThursdaybetween8amand5pmandonFridaysuntil2.30pm(CentralEuropeanTime).

KRONOPLY on the InternetOurcompletelyredesignedandreorganisedKRONOwebsitenowfeaturesevenmoreserviceandastrongercustomerorientation.It’seasy,straightforwardandquicktoaccessproductinformation,news,services,specialsanddownloads.Youcantakeadvantageofthefollowingcontent24/7:

■ Informationmaterials ■ References■ Datasheets ■ Deliveryprogramme■ Certifi cates ■ Biddingdocuments■ Constructiondetails ■ Exampleapplications■ Condensationcalculator ■ U-valuecalculator■ Tradefairsandotherevents ■ Contacts■ Environmentandsustainability ■ Andmuch,muchmore!

Service Hotline: +49 (0) 3396� 69-751

You’ll fi nd additional information at: www.kronoply.com

Page 42: KRONOPLY OSB Complete Portfolio en 0611

KRONOPLY GmbH Wittstocker Chaussee 1, D-16909 Heiligengrabe

Tel.: +49 (0) 33962 69-740, Fax: +49 (0) 33962 69-376 E-mail: [email protected], Internet: www.kronoply.com

SWISS KRONO GROUP

Complete OSB brochure finalised in June 2011 Photographs: KRONO, shutterstock, fotolia, BEMA in Wald-Michelbach, AG Passivhaus

Subject to technical changes. No liability accepted for printing errors, incorrect standards or other mistakes.

Yourpartner


Recommended