Simple Solution
Supply Record
(Oversea/Domestic)
Simple Solution
Pre-terminated
Systems
Intelligent
Infrastructure
Management
System
Intelligent Power
Management
System
Fiber/Copper
Systems
Rack /Tray
Solution
Structured Cabling Solution for IBS/DC
Wireless AP
Systems
SCS Solutions
Copper
cables(C5e,6,6P,6A)
1
1
Fiber Cables
(SM, MM1)
2
2
Copper Patch solutions
(Panel & M/J, P/C)
3
Outlet solution
(SMB,F/P)
4
Fiber Patch
solutions(FDF,P/C)
5
SoHo & Consolidations
(Box, Mini Patch)
6
Telecommunication Racks
& Grounding
7
Multiplexers8
3
4
5
6
7
8
Access Point 9
9
Data Center Solutions
Main Distribution Area (MDA) &
Horizontal Distribution Area (HDA)
Zone Distribution Area (ZDA)
Entrance Room (ER) &
Telecommunication Room (TR)
Equipment Distribution Area (EDA)
Next floorCopper (C7,6A,6Plus)1
Fiber(OM3,4)2
Simple Fast Net™3
Simple Fast-Net™ MPO5
Simple Closet™
(HDR, Cooling
Manager)
6
Simple Paths™ 7
Simple View™ IPM 8
Simple View™ IIM9
Simple Fast-Point™10
Simple GXC™ Patching4
1
2
3
4
56
7
89
10
Simple Solution
Copper Solution
Exceed performance ANSI/ TIA/EIA-568-B and ISO 11801 2nd standards requirement
To optimum performance, all LS Cat. 5e, 6, 6A, 7 Cable, Jacks are 100% tested, delivering a cost effective media for high-bandwidth IBS / Data Center applications
Smaller Diameter Cables enable more air flow –> Better Cooling
Pre-terminated Copper Solution : Quick deployment ( Plug & Play )
Installs 75% faster than field-terminated
methods
Simple Solution
Copper Solution
UTP Cable
Insulation(PE, FEP)
Pair
PVC/LSZH Jacket
- Cat5
- Cat5e
- Cat6 (Non-Filler)
Insulation (PE, FEP)
Pair
PVC/LSZH Jacket
Cross Filler
UTP Cable
- Cat6 (Filler)
UTP Cable
- Cat6A (10G)
Round Filler
Insulation(PE)
1st Layer (10P Layer)
2nd Layer (15P Layer)
PVC/LSZH Jacket
UTP Cable
- Cat5e 25P
- UL Certification
PE Insulation
Pair
Earth wire
PS Tape
Al/Mylar Tape
PVC/LSZH Jacket
FTP Cable
-Cat5 & 5e 4P
- Cat6 4P
- Cat6A 4P
S-FTP Cable
-Cat5e 4P
- Cat6 4P
PE Insulation
Pair
PS Tape
Al/Mylar Tape
Tinned Copper
PVC/LSZH Jacket
Insulation (PE, FEP) PairCross FillerPVC/LSZH Jacket
Simple Solution
Copper Solution ( Cat 6A )
Cable diameter
8mm (Patent
Pending)
Int’l Standard
Certified (UL etc)
W17.6, H20.6, D31mm
Int’l Standard Certified
Minimized Alien-talk
between near ports
Convenient wiring with
slim structure
High credibility
Labeling, Jack, Patch
cord, Panel suitable for
Data center
Complied with TIA/EIA
568B.2-10, ISO11801 2nd
Class E, TIA 942, Fcc Part 68
and KCC
High Margin on Transmission Performance
Complied with TIA/EIA 568B.2-10,
ISO11801 2nd Class E and TIA 942
PVC(CMX/CM/CMR/CMP), LSZH(CMX)
Improved Alien X-talk & Reduced cable
diameter with ‘H’ type filler
Patent Pending
Simple Solution
Plenum Cable
UL 910 (Plenum Test)
smoke density regulationPVC
Non-Plenum Cable
UL 1666(Riser Test)PVC
Non-Plenum Cable
UL 1581(VTFT Test)
IEC 60332-3
smoke density regulation for LSZH
PVC
LSZH
Europe CMX/CM rated LSZH
USA CMR/CMP rated PVC
(Toxic gas generation standard is specified for LSZH to minimize the chance of loss of lives under fire.)
(CMP does not make combustion of sheath & insulation under fire.)
Usage according to
flame-retardant ratedStandards & Regulations Sheath
Th
e h
igh
er
the l
evel
of
cla
ss i
s,
the l
ess t
he l
oss o
f lives
by t
he c
ab
le i
s
CMP
CMR
CM
CMX
CMR for risers between floors
for horizontal cabling
for regular residential cases
for high flame-retardant
wiring for horizontal
PVC
LSZH
Non-Plenum Cable
UL 1581 (VW-1 Test)
IEC 60332-1
smoke density regulation for LSZH
Simple Solution
Copper Solution ( Fast-Net TM )
Channel
②pre-terminated
panel & module
③ six bundle
cable
① six bundle
patch cord
④ equipment
cord
①
Simple Solution
0
10
20
30
40
50
60
70
80
90
100
1 2
`
① Patching & Cord
Arrangement
② IDC Connecting
(Terminate)
③ Test
④ Labeling
⑤ Pull Cabling &
Bundle
Maximum 8 times Time Saving
①
②
③④
⑤
Copper Solution ( Fast-Net TM )
Simple Solution
Product Line
Patch Panel
Cat5E Cat6 Cat6A
Modular Jack
12 / 24 / 48 Port 24 / 48 Port
Wire management Modular Jack Type
Wire management
UL Approval & RoHS Compliant
Unshield & Shield type available
Tool less available
Shutter type available
Tool less available
Shutter type available
Unshield / Shield
IDC / SI / Tooless type
Channel Performance can reach to additional Margin with High quality LS SimpleTM Patch Panel / Modular Jack
Reliability; 100% factory tested
Copper Solution ( Connectivity )
Simple Solution
Patch Cord
& Plug
Face Plate
Various Color (GY, WH, BL)
Unshield & Shield Type
Specialized Cat.6 Plug
Unshield & Shield Type ( 50 u-inch gold plating)
European & US type with Back box SMB with
Modular Jack
Others
110 Block with IDC Cabinet with accessory
Copper Solution ( Connectivity )
Simple Solution
Fiber Optic Solution
LS SimpleTM Fiber Optic Cable is a highly reliable and interoperable system with the flexibility and adaptability to evolve with technological demands
Supports 10 Gigabit Ethernet applications while maintaining compatibility with existing 50um multimode systems.
Plug & Play; quick & ease of deployment ( MPO )
Reliability; 100% factory tested
Long Haul , Metro, Access, Premise
Simple Solution
144F
288F
432F
864F
Small Cable
(1+2, 1+3)
L/T Type
(SZ Stranded)
Micro Cable
L/T* Type
(Dual Layer)
Ribbon
Slot Type
( ~ 1000F) R/T* Type
(288 ~
1152F)
Mini-Flex
( ~ 144F)
C/R Type
( ~ 432F)
Counts
Bundle
C/T Type
- High Counts Cable
- Mass Splicing(Ribbon)
- Dry Core Structure
72F
48F
24F
Metro
ABF*
1~12F
ABC*
14~48F
Air Blown
Long haul - L/T Cable
- Micro Cable
Drop Cable
(1 ~ 12F)
DT
12F
- Small Size
- Light Weight
- Easy Fiber Access
- Varies Type of Cable
- Flexibility
(Easy Handling)
- Small Counts
- Light Weight
Access Premise
* M/T : Multi Tube
* L/T : loose Tube
* C/R : Central Ribbon
* C/T : Central Tube
* R/T : Ribbon Tube
* ABF : Air Blown Fiber
* ABC : Air Blown Cable
* WB : Water Blocking
Fiber Optic Solution ( FO Cable )
Simple Solution
Simplex Cord Zip-cord Duplex Round Duplex Flat
Ribbon Cord D-type Single D-type Multi Unit Breakout
Structure Dimension
Cable Type Dimension
Simplex Cord 1.6mm, 2.0mm, 2.4mm, 2.9mm
Zip-Cord 1.6mm, 2.0mm, 2.4mm, 2.9mm
Duplex Round 5.1mm
Duplex Flat 6.8 (W) x 3.9 (H)
Distribution6C: 5.7mm, 12C: 6.7mm, 24C: 11.0mm
24C: 12.8mm, 48C: 15.4mm
Ribbon Cord2C, 4C : 3.5 (W) x 2.5 (H)
8C, 12C : 4.5 (W) x 2.5 (H)
10,40&100 Gb/s
Transceiver DesignationWavelength
62.5
(OM1)
Std50
(Om2)
LO 50
(OM3)
LO 50
(OM4)
SM
(OS1)
10GBase-SR
(10Gb/s)
850nm
Serial VCSEL33 82 300 550 NA
10GBase-LX4
(10Gb/s)
1300nm
CWDM Laser300 300 300 300 10,000
10GBase-LRM
(10Gb/s)
1300nm Serial
Laser/EDC220 220 220 220 NA
40GBase-SR4
(40Gb/s)850nm Parallel VCSEL NA NA 100 150 NA
100GBase-SR10
(100Gb/s)850nm Parallel VCSEL NA NA 100 150 NA
Simple Solution
Modular Panel MPO CassetteMPO Fan-out Cord
MPO Patch Cord
Backbone & Workgroup Switch
Hub
MPO Interface Server &
Information MonitorIDF MPO PanelMDF MPO Panel
Fiber Optic Solution ( MPO )
• Pre-terminated MPO Cassette mounted Panel
• Copper & Fiber Compatible solution
• up to 72C adaptable
• Pre-terminated Module
• 12C~24C adaptable
• LC / SC
• Pre-terminated Cable, 12C~24C support
• Insertion Loss ≤0.75dB, ≤0.5dB(MM)
• Return Loss ≥45dB
• IEC61754-7, TIA/EIA 604-5
Features & Benefits Plug & Play; quick & ease of deployment Modular & Scalability Reliability; 100% factory tested 10GB performance High density support; 72 fibers in 1RU
Simple SolutionSCS F/O Solution Products
Features LC SC ST FC
F/O Connector
• Various type of
Connector
- LC, SC, ST, FC,
MTRJ, MPO, E2000,
etc…
F/O Adapter
• Used to couple and
mate optical jumper
cords
• Sleeve material
- ceramic or bronze
F/O Jumper
Cord
• Pull Proof
• Very easy to connect
or disconnect
• Low IL / RL
• Small & High Density
Fiber
Distribution
Frame
(FDF)
• Connection Capacity
- 12, 24, 48 Core
• Various type of Frame
body
- Standard, Drawer,
Swing, Empty type
• LC, SC, ST, FC, etc…
Standard Type Swing Type Draw Type
Simple Solution
High Density Rack/Cabinet
Enabling Green Data Center Optimization such as Space saving, Management efficiency, thermal management.
Enabling scalability for data center expansions and network upgrades
Designed to endure earthquake level 7 with 300kg weight,to pass 1000kg pressure test
Simple Solution
Model
LS-MDF-4P LS-S-C LS-B-C LS-OP-2P
ApplicationPrivate computational office,
computational office
Public computational office Essential equipment such as DB ,
Network backbone
Constitution of MDF , IDF
Dimension
• Height : H2130
• Depth : D900 or 1000
• Width : W600
• Reference : 42U
• Height : H2130
• Depth : D1000
• Width : W700 , W800
• Reference: 42U
• Height : H2130
• Depth : D1000
• Width : W700 , W800
• Reference: 42U
• Height : H2130
• Depth : D360
• Width : W600
• Reference: 45U
Matter / Load Steel / 1000kg Steel / 1000kg Steel / 1000kg Steel / 1000kg
Door ( Choice )
Common use of Front , Rear
• Mount Frame : RMU Marking
• Possible In/Out of inner socket without the interference of the rear.
• Free movement of Mount Frame according to the length of equipment.
• Offer of hook-shape Shelf/Guide Angle : Bolt fixation not required.
• Compatible in Patch work of Data Center
• Innovative improvement of current Open
Rack Cabling inside the Apartment MDF.
• Mount Frame : Line Nut way.
• 2 POST Rack , 4 POST Rack
Airflow• Natural Airflow • Over 70% rate of Punch in the front/rear door for the heat
management.
• Natural Airflow
Wiring
Vertical Cable Management
at inside the front/rear of Rack.
Internal wiring by itself
without VCM
Plastic burning resistant (ABS)
Vertical Cable Management
inside the front/rear of Rack.
Simple Solution
Cooling System
Cost reduction by Hot zone and Cool zone
arrangement : Energy efficiency
optimization.
Hot Air backflow prevention.
Design considering natural airflow : keep of
temperature inside the Rack.
High Intensity Wheels Stability
Carrying maximum of 1,000KG /
movement possible.
Possible movement with the mounted
Server in time of Rack rearrangement.
Stability made possible by unification of
Rack/Tray and connection support : not
affected by outside impact
High Stability compared to the others
because of extra connection Bracket used
in connection of Racks.
Main Feature - efficiency maximization
Simple Solution
Depth Size Increase Easy Adjustable Exclusive Space for Power-strip
Adjustable front back based on equipment
RMU Indication.
No affection to Power-strip even if the
server’s size is long.
2 Power-strips can be installed in one side.
Easy placement and displacement due to
the hook shape of the power-strip.
Insured work space in the rear of Rack and
possible addition of Power-strip even with
the 850mm server.
200m
m
2*2
Main Feature – space application
Equipment rail RMU indication
Simple Solution
Hook Shape
Screw work not required.
Easy attachment able to be done by anyone.
Installing time reduction : RMU Marking, which can be easily
checked by eyes.
Minimization of Hindrance
Complete Separation of Network Cable and Power Cable : No twist
between cables.
Prevention of human error : cables organization can be easily checked
by eyes.
Network Cable
Power Cable
Main feature - Convenience in Application
Simple Solution
② Filler panel ③ Cold aisle front/rear doorCold aisle Hot aisle
① Upper-board
Possible to open and shut and to
observe inner situation
Prevent cool air to be mixed with warm air
by blocking top of Cold aisle
① Upper-board
High Density Rack/Cabinet ( Upper Board )
Simple SolutionExisting rack arrangement
Existing average temperature : 20
Month-Wattage of rack cooling for 400‘s : 328,572 kWh
Month-electricity charge of cooling per rack
: $ 55 / Month ($0.07 per kW)
Temperature as application of UB : 16 (7% energy reduction per
1)
Month-electricity charge of cooling per rack : $40 ($15 reduction :
28%)
Investment payback : 12.5 months
Rack arrangement after installed Upper board
Simple Solution
MTTR(Cabling)
Time to recoveryTime to failure point acknowledgement
MTTR(Network)
Time to revoeryTime to failure point acknowledgement
80% 20%
30% 70%
LS SimpleVIEW Physical Layer Management System
Provide physical information
Monitor patch panel connections
Monitor location of end devices
Remote guided patching
Automatic update of physical layer documentation
• Patching is cumbersome.
• The database is inconsistent with the actual
connections.
• Difficult to know which port is usable.
• Updating the database is a burden for the IT manager.
IIM ( Simple View TM )
Simple Solution
LS SimpleVIEW Physical Layer Management System
Patch field database is 100% accurate assuring network reliability and efficiency
Security & Risk Manangement : Asset Tracking, real time identification
Operation Efficiency : Capacity planning, Reduce Mean Time to Repair(MTTR), MACs control
A return on investment (ROI) model
IIM ( Simple View TM )
Simple Solution
LS SimpleVIEW Physical Layer Management System
• Real time management tool to manage physical infrastructure
• Provide automatic updated physical layer documentation
• Assist in fault identification & troubleshooting
• Enhance security through accountability
• Asset management
• Support 3rd network management system
Simple Solution
• Intelligent patch panels convey changes (insertions or removals) to expanders and scanners.
• Expanders and Scanners continuously monitor panels for connectivity changes.
Connectivity change monitoring is done via out-of-band signaling via hardwired attachment cables between devices.
A proprietary protocol is utilized for this purpose
• Master modules communicate with expanders and scanners via direct Ethernet type attachment cables and a proprietary protocol.
• Master modules communicate with the SimpleVIEW ™ management system via SNMP protocol.
Simple Solution
Scanner
60
31
19
24 24 12
Master
Expander
Scanner
Scanner
19
24 7
Scanner
Scanner
Simple Solution
LS Simple IPM Physical Layer Power Management System
One of the major concerns facing data centre planning & implementation is providing and controlling sufficient power.
real/historical monitoring environmental components ( Power, tempature, humidity, smoke, security ) in Cabnet
Environment Sensor ( Temperature, Smoky, Door, Humidity )
Non-invasive power consumption monitoring ( SPV )
Remote rebooting / switching
IPM ( Simple View TM )
Simple Solution
Power
Space
- A large sized Data Centre consumes the same amount of Power as
an average sized Town
- A typical Data Centre containing 1000 racks will require approximately
15 MWatt of Power [15,000 x 1kWatt electric fires]
- 30% of todays IT budget is spent on Power and it’s increasing
- Power demand is increasing [Moores Theory]
- Government tax on Power efficiency/Carbon Neutral
- Corporate Image and Policies to be seen as Environment friendly.
- Demand for larger kWatt/sq M foot print requirements for new Blade Server
Technologies. Has led to the Development of 30-40 kWatt Cabinets
- Power in = Heat out which requires cooling, which requires power.
- Elevated Temperatures [and Humidity], will cause Pay Load equipment to fail
due to increased component stressing and premature ageing
- Temperature is not even in a Data Centre, Hot spots will develop and move
from hour to hour, day to day.
New Build
- Green sites can use the latest IIM technology.
- Space can be purpose planned
- ’Lights out’, unmanned space can be designed using LS Simple IIM Technologies
Retrofit
- Space is limited, Not purpose designed
- Need to integrate with existing and New technologies
- Cannot shut facility down, Retrofit/Refit, LS ‘Simple IIM solutions can be
designed to be Non- Invasive
Cooling
IPM ( Simple View TM )
Simple Solution
- Monitoring was Local only at point of entry into Data room i.e. Power Distribution boards
- Temperature was measured via BMS, remote from the Payload equipment.
- Load values / cabinet was occasionally recorded manually with a hand held CT.
- No accurate records, real time measuring, identification of Temperature / Power hot spots.
- No Monitoring, No Management, Not a problem, energy was cheap and plenty, Power foot print per sq M typically was 1-3 kWatt, easily obtained
- Today 21st Century Data Centers require more Power and Cooling
- Power supply is limited and expensive
- Maximization of expensive resources to minimize waste, reduce costs
- Maximize of Payload operations, preventative Maintenance, zero downtime, Maximization of operations
- Todays Data Centers cannot function without IIM solutions.
- Todays Data Centers are Designed and Categoried in tiers to quantify the degree of
Security and resilience built into the Data Centre.
Previous Present
Historical Methods of Monitoring & Control
Simple Solution
• Intelligent Power Management
• Combination of hardware and software for power distribution & usage
optimization
• Monitor the power consumption of equipment
• Monitor datacenter environment
‘Aim is to improve energy efficiency and reduce emissions’
What is IPM
IPM ( Simple View TM )
Simple Solution
• Capacity planning - typically users run out of power or cooling before anything else
• Need to know where energy is being used.
• Need to know where energy is wasted
• Business planning & technology refresh - Understand why and where energy performance is
poor, how to improve it & build business cases
• Physical & Network security – human error a major cause of failures (audit trails)
• ‘Real time’ monitoring and alerting – early warning maximises time available to respond
• Need to know where energy demand is going to shortly exceed capacity.
• Eliminate downtime caused by undiagnosed environmental disturbances
• Government Legistration : The Carbon Emission Commitment
Why Monitor ?
Simple Solution
Simple Solution
37
Humidity
Sensor
Monitored
and
controlled
power strips
Temperature
Sensor
Electronic Door
Lock
Keypad/HID Card Reader
In Line Power
Monitoring
LCD Status
Display
Remote console
management
Simple Solution
• Compact Zero-U SNMP monitoring unit.
• External 12VDC Power supply (90~240VAC adapter).
• Monitoring & Control of 2 Power Strips
• Monitoring of 2 Sensors.
• Support for 2 line 32 character LCD status display.
• 10/100 Ethernet support with speed & Link LEDs.
• Power, Status and Alarm LED indicators.
• Reset and Mode switches.
• Configuration information stored in 64KB EEPROM
• Firmware upgradeable in the field.
• Protocols; TCP/IP, UDP, SNMP v2.3, TFTP, HTTP, HTTPS, SMPT, SNTP, SYSLOG, LDAP.
• User interface for configuration & status monitoring provided through web pages.
• User configurable alarms; transmission of SNMP alerts when pre-defined thresholds crossed.
• Configurable EMAIL alerts, on specified alarm conditions.
• Support for SYSLOG allowing configuration and alarm events to be audited remotely.
• Built in real time clock, with backup battery, and SNTP network time support.
• Supplied with mounting bracket and power adapter.
• Dimensions: 130mm x 80mm x 30mm. 150gm.
Intelligent Power View 1 ( i-PV1)
Simple SolutionIntelligent Power View 2 ( i-PV 2 )
• 1U 19” dedicated rack SNMP monitoring/control unit.• Monitoring & control of 4 power strips• Monitoring of 6 sensors.• Support for 2 line x 32 character LCD status display.• Support for 2 relay outputs (N/O and N/C Contacts
available)• 12VDC output on relay connector fused to 1A to power
external devices.• Support for 2 serial keypads.• Support for 2 HID smart card readers. (Alternative to
keypads).• 10/100 Ethernet support with speed & Link LEDs.• Input sensor types supported;
Temperature, Humidity, Open/Close contacts, 0-10VDC analogue input.
• Dual power supply feeds, with status LEDS Feed-A/Feed-B
• LEDs indicate, DC power, System Status, Alarm state
Simple SolutionIntelligent Power View 3 (i-PV 3)
• 1U 19” Multi-rack/Computer room SNMP control unit.• Monitoring & control of 6 power strips. (expandable to
24).• Monitoring of 12 sensors. (expandable to 96 inputs)• Support for 2 line x 32 character LCD status display.• Support for 4 relay outputs N/O and N/C Contacts
available. (expandable to 18 relay outputs)• 12VDC output on relay connector fused to 1A to power
external devices.• User programmable logic control of output relays (based
on Inputs & access control state).• Support for 2 serial keypads or 2 HID smart card
readers. (expandable to 8)• 10/100 Ethernet support with speed & link LEDs.• Input sensor types supported;
Temperature, Humidity, Open/Close contacts, 0-10VDC analogue input.
• Dual power supply feeds, with feed status LEDS Feed-A/Feed-B.
• LEDs indicate, DC power, System Status, Alarm state.• Reset and Mode switches.• Firmware upgradeable in the field.• Protocols; TCP/IP, UDP, SNMP
v2.3, TFTP, HTTP, HTTPS, SMTP, SNTP, SYSLOG, LDAP.• Web interface provided for configuration & status
monitoring.
Simple SolutionPDU Power Strip
Power Strips
– Built in electronic measuring circuits to monitor; Voltage, Current, Power Factor, Frequency, kVA, kWhrs. (Using CT & VT).
– Parameters displayed on 2 line 32 character backlit LCD display.
– Measuring circuit powered from SNMP monitoring unit.
– RS232/RS485 data link to SNMP unit.
– Designed to customer specification.
– Choice of Zero-U or 2U Form factors.
– 16A or 32 Amp feed cables terminated with BS EN 60309-2 Plugs (16A / 32A 250VAC).
– Choice of out let sockets:
• EN60 320 C19 Sockets (16A 250VAC)
• EN60 320 C13 Sockets (10A 250VAC)
• BS1363 (UK13A) Sockets (13A 250VAC)
• CEE 7/4 Shuko (16A 230VAC)
• Any combination of above socket types subject to physical size constraints.
– Other options:
• fused or fused + indicator per outlet.
• Circuit breaker per power strip / circuit.
• Relay control of each outlet On/Off (Max 24).
• PSU for relays built into the power strip.
• Switched outlet options of;
– Normally open relays.
– Latched relays.
– SNMP control unit can automatically sequence up Power outlets to prevent power surges.
Simple SolutionSPV Kit
• Non Invasive A.C. Electrical Current Monitoring unit
– A small compact electrical current meter capable of measuring A.C. currents on typical data centre 16A and 32A power supply feeds.
– Attachment does NOT require power down of the measured feed.
– Capable of measuring A.C. electrical currents up to 60A.
– Built in LED display provides two digit readout.
– CL-Amp appears as a standard PDU to the PowerHawk-2, Hawk-i2, Hawk-i3 and Eagle-i units.
– Uses patented technology for current measurement in the Data Centre, Computer room and PC environments.
– Current measuring range 1.0 Ampere to 60 Amperes.
– Measured supply range: 90VAC ~ 250VAC Frequency: 50Hz ~ 60Hz A.C.
– RS232 / RS485 Communication link to UTL monitoring units, providing SNMP data collection and monitoring, and configuration of CL-Amp.
– RJ45 connector for direct connection to PowerHawk-2, Hawk-i3 and Eagle-i. Unit – derives 12VDC power from UTL monitoring device..
Simple SolutionIPM Management Software ( Env-U / DCIQ )
Colour code cabinets by Amps, Temp, Status etc
• Easy to use
- Clear, easy to read intuitive screens using
- Automatically discovers supported
• Logging
- Individual device log files
- Easily manage inventory and create and save custom
reports
• Intelligent Alarm Processing
- Active alarm
- Automatically updates and display
Simple SolutionIPM Management Software (Env-U )
Designed for temporary or small scale installations
Tables, graph and export functionality
Simple SolutionIPM Management Software (DCIQ )
Designed for Global/Enterprise scale installations
Simple SolutionIPM Management Software
Tailored Reporting (SQL) Environment Report
- Temperature / Humidity
Rack Report
- Temperature / Humidity / Power / Power Usage Report
PDU Reports
- Power Report / PDU Load
Simple Solution
Finance Blue Chip
Universities
Local Govt.
Blue Light
Simple Solution
Overhead Routing System ( Simple pathTM )
LS Simple Overhead Routing System, SimpepathTM enhances reliability through bend radius
protection and physical protection
Lighter weight system requires less expensive infrastructure : PC(Polycarbonate)/ABS,
Hallogen-free
Reduces installation cost in ½ time of ADC’s fiber protection system
Achieve maximum design flexibility and growth potential.
Simple training show room
Simple Solution
Feature & Benefit
Overhead Routing System ( Simple pathTM )
Simple Solution
Comparative Test Result
Overhead Routing System ( Simple pathTM )
No
SPEC
Unit
LS P K W
TEST ITEM
(Mechanical Test)TEST METHOD KOR USA USA AUS
1 Tensile Strength ASTM D 638 : 2008 Mpa 62.8 59.7 50.9 57.2
2 Indentation Strength ASTM D 790 : 2007 mpa 105 99.8 85.1 97.8
3 IZOD Impact Test ASTM D 256 : 2006 J/m 1,256.
00
1,193.2
0
1,017.4
0192
1 Flammability Test UL94 / V-0,V-1,V-2 - V-0 V-0 V-0 V-0
2 Rohs IEC 62321 Ed.1 mg/kg N/A N/A N/A N/A
3 Bromine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A
4 Chlorine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A
5 Fluorine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A
6 Iodine Hazardous Substance EN 14582(IC) mg/kg N/A N/A N/A N/A
Simple Solution
inch
Brand
12”
300mm
8”
220mm
6-1/2”
160mm
6”
150mm
4”
100mm
2”
50mm
1-1/4”
30mm
Round
Flexible
Tubing
Square
Flexible
Tubing
COO
LS
Simpe pathO O O X O O O O O KOREA
W&S
LightPathsO O X X O O O O X AUS
ADC
Fiber GuideO X X O O O X O X USA
Lucent X X X X O O X X X USA
TII X X X X O O X X X USA
Telect
WavetraxX X X O O O X X X USA
Competing Against other Ducting Systems
Simple Solution
Enable Cable length Minimization
Easy Additional cabling adding
No interfere air flowing from under floor on cold asile
Before After
Simple Solution
Main Duct
30/50/100/160/220/300mm
Width
① ②
① Main Duct
③ Joiner
② Cross
④ TEE
⑤ Horizontal Elbow
⑥ Vertical Elbow
⑦ Reducer
⑧ Outlet Drop Slot
⑨ Outlet Trumpet
Suspension Sets
Cross
Cabling for 4 ways
100/160/220/300mm Width
⑩ Side Drop
Bracket
11
③
④
⑤
Joiner
Joining each item
50/100/160/220/300mm
Width
TEE
Cabling in 3 ways
30/100/160/220/300mm
Width
Vertical Elbow 45 deg.
90 deg with Joiner
50/100/160/220/300mm
Width
Horizontal Elbow 45 deg.
90 deg with Joiner
30/100/160/220/300 mm
Width
⑥
UP 90 deg. DOWN 90 deg.
Simple Solution
Simple Solution
⑨
⑩
⑧
⑦
Reducer
Connecting on different size
100 -> 50 / 160 -> 100 / 220
-> 160 / 300 -> 220
Outlet Drop Slot
Cabling Exit
100mm Width
11
Outlet Trumpet
Install the end of Cabling
Exit
100mm Width
Side Drop Bracket
Maintain Outlet Drop Slot
⑧
⑩
⑨
Suspension Sets
Holding up Raceway
System
Simple Solution
Wireless Acess Point ( Simple Fast-Point TM )
Increase work efficiency and convenience
using VolP Phone, Laptop, PDA which works in a
wireless network system in side data center
Simple Solution
Operating
room
Data Center
Back
bone
LS Wi-Fi Access Point
LS PoE Switch
LS Wi-Fi Access Point
LS PoE Switch
Data+Power
Simple Solution
802.11b/g/n
1 port 10/100Base-Tx wth PoE PD
2x2 MIMO(Multi-Input, Multi-Output)
WEP64/128bit, 802.1x, ESSID
WMM(WiFi Multimedia), WPS(WiFi Protect Setup)
NAT/Bridge mode
DHCP Server, Client
Web-based Management, SNMPv1/2
LS Wi-Fi AP has applied IEEE 802.11n draft 2.0, providing users with high bandwidth and wide coverage
when using Volp Phone, laptop, and PDA.
Its application of IEEE 802.3af PoE also helps provide data and power by LAN cable, making it easier to
install.
Simple Solution
Wireless Acess Point ( Simple Fast-Point TM )
Layer 2 swithch which IEEE802.3 Ethernet
based data communication and IEEE802.3af
standard based Power Source works
simultaneously.
supports VLAN, RSTP, QoS which
optimizes traffic flow and bandwidth usage
Reduce additional cost to provide power to
the eqipment
24 port 10/100Base-Tx with PoE PSE for
subscriber
2 port 10/100/1000Base-T or SFP for
uplink
Non-blocking switching, Store and
forward structure
VLAN, Multicast, STP/RSTP, Packet
Classification, QoS function
Web-based, SNMP control function.
19” Rack mount Box type
Certification List
Simple Solution
KS
• CM 2P ~ 600P
• CMR 2P ~50P
UL
• 4P ~ 25P
• CMX, CM, CMR
ETL
• 25P (CM, CMR)
DELTA CE
• 4P (CM, CMR)
• 25P (CM,CMR)
• 4P
(CM, CMR, CMP)
• 25P (CM, CMR)
• 4P (CM, CMR,
CMP)
• 25P (CM, CMR)
• 4P
(CM, CMR, LSZH)
• 25P
(CM, CMR, LSZH)
• 4P (CM, CMR)
• 4P (CM, CMR) • 4P (CM, CMR,
CMP)
• 25P (CM, CMR)
• 4P (CMP) • 4P
(CM, CMR, LSZH)
• 4P
(CM, CMR, LSZH)
• 4P (CM, CMR) • 4P
(CM, CMR, CMP)
• 4P (CMR, CMP) • 4P (CM, LSZH) • 4P (CM, LSZH)
• 4P
(CM, CMR, CMP)
Cat 3
Cat 5
Cat 5E
Cat 6
Cat 6A
• RoHS Compliant for all products
Certification
Simple Solution
Cannel Certificate (ETL)
Certification
• Cat 5E
• Cat 6
• Cat 6A
• ISO 9001
• ISO 14001
• OHSAS 18001
Certification
Simple Solution
Why LS Simple?
Simple Solution
• Top Tier Technology
- Cooperation with R&D Group, Technical Innovation, Production EfficiencyQuality guaranteed products
• Diverse Product Range
- Copper/Fiber SolutionConnectivity SolutionRack/CabinetIIM/IPM
• Quality Control
- ISO 9001/14001, UL/EC Certified, RoHS
• Quick Response for promotion
• World Class service level
Supply Record
Supply Record
•Name : New Park Plaza Hotel (Westminster Bridge)
•Address : London, UK
•Size : Total 7,000Port (Cat6 Data & OM3 Fiber)
•Scheduled on July, 2009
•Remarks :
- Biggest hotel with 1200 rooms in UK
- Schedule to supply cable and connectivity
to New Park Plaza which is composed of 7 buildings
•Name : Torino City Government
•Address : Torino, Italy
•Size : Total 5,400Port (Data & Fiber)
•Scheduled on July, 2009
•Remarks:
- Re-construction Telecom Italia buildinng
to Torino city hall
- Positioned in torino commercial complex
Oversea
Supply Record
Oversea
•Name : Portugal Telecom school Project
•Address : Portugal
•Size : Total UTP 4,150 Km, FTP 1,200 Km,
with connectivity
•Scheduled on Nov.2008~Sep.2009
•Remarks :
- Governmental business for School Project
•Name : Social Security (Hospital for 3years contract)
•Address : Spain
•Size : FTP Cat6 Solution (1M$)
•Scheduled on Feb.2008~Nov.2011
Supply Record
Oversea
•Name : Telefonica Empresas
•Address : Spain
•Size : Data & Fiber
•Scheduled on Nov.2008~
•Remarks :
- Network and maintenance
Telefonica Empresas is biggest telecommunication
company in Europe
•Name : Valencia University
•Address : Valencia in Spain
•Size : Central building and Medical center
(Cat6 Data & Fiber, 150kUSD)
•Finished on Aug. 2008
•Remarks :
- Network installation for Central building and
Medicine university
- Scheduled to be extended for other building
Supply Record
Domestic
•Name : Nurikkum Sauare
•Address : Sangam-dong, Seoul
•Size : Total 50,000Port
• (Data/Voice : 40,000, Fiber : 10,000)
•Completed on Dec, 2007
•Remarks :
- Domestic biggest intelligent building
- Domestic first Data & Voice & Fiber
intelligent system building
- Management telecommunication room separately &
PDA Solution
•Name : Songdo u-IT cluster RFID/USN center
•Address : Knowledge & information complex,
Songdo, Incheon city
•Size : Total 3,000Port (Data & Fiber)
•Completed on Feb, 2008
•Remarks
- Strategic place for IT-hub implementation
in north-east asia.
- 3 places implementation additionally by 2010
Supply Record
Domestic
Name :Kyeonggi Bio center
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : Institute of NGC
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : LS Tower
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : World marine center
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : Sangam-dong LGT Building
Solution : Cable + Connectivity
Remarks: Cat.6A(10G) SCS solution
Name : Korea Ad culture center
Solution : Cable +Connectivity
Remarks : Cat.6 SCS solution
Supply Record
Domestic
Name : Yangjae chilren’s hospital
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : Korean art school
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : icheon city hall
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : Taeback Safety Theme park
Solution : Cable + Connectivity
Remarks : Cat.6A(10G) SCS solution
Name : Kimhae Airport extension
Solution : Cable + Connectivity
Remarks : Cat.6 SCS solution
Name : Sangam-dong LGT Building
Solution : Cable + Connectivity
Remarks: Cat.6A(10G) SCS solution
Your No.1 Creative Partner