Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
1
A LABORATORY MANUAL
FOR
Chemical Engineering
Laboratory –I
Edited By
Dr Suresh Gupta & Dr Hare Krishna Mohanta
Department of Chemical Engineering,
Birla Institute of Technology & Science (BITS), Pilani
September 2014
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
2
CONTENTS
CYCLE - I
S. No. Experiment Page No.
1. a. Flow through Fluidized Bed (Gas and Water)
b. Flow through Packed Bed (Gas and Water)
3
2 . a. Losses due to pipe fittings
b. Losses due to friction in pipes
c. Drag Coefficient determination
10
3. a. Bernoulli’s Theorem verification
b. Discharge through venturi, orifice and rotameter
c. Flow through tubular pipe
22
4. a. Pitot tube experiment (Air and Water)
b. Reynolds Apparatus
34
5. a. Centrifugal pump characteristics
b. Reciprocating pump characteristics
42
6. a. Heat Pipe demonstrator
b. Thermal Conductivity of solids
c. Thermal conductivity of liquids
52
7. a. Drop wise and film wise condensation
b. Unsteady state heat transfer unit
61
8. a. Heat Transfer in agitated vessel
b. Fluidized bed heat transfer unit
76
9. a. Parallel flow & Counter flow heat exchanger
b. Shell and Tube heat exchanger
83
10. a. Plate type Heat Exchanger
b. Finned tube heat exchanger
92
CYCLE - II
S. No. Experiment Page No.
11. Stefan-Boltzmann Apparatus
151
12. Cross-circulation drying apparatus 110
13. a. Vapour in air diffusion
b. Open pan evaporator
114
14. Simple/Differential distillation setup 120
15. Batch crystallizer 125
16. a. Steam distillation setup
b. Vapor liquid equilibrium setup
128
17. Two phase flow 136
18. Mass transfer with chemical reaction 141
19. Adsorption in packed bed 144
20. Humidification in wetted wall column 148
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
3
EXPERIMENT NO. 1(a)
FLOW THROUGH FLUIDIZED BED (AIR & WATER)
1. Aim
Study of hydrodynamic and bed characteristics for flow through fluidized beds.
2. Objective
To determine the minimum fluidization velocity experimentally as well as
theoretically.
To study the bed expansion characteristics of the fluidized bed (plot log NRe vs.
porosity and pressure drop vs. NRe).
3. Apparatus
Stop watch, graduated cylinders, beakers
4. Theory When a liquid or a gas is passed at very low velocity up through a bed of solid particles, the
particles do not move, and the pressure drop is given by the Ergun equation. If the fluid
velocity is steadily increased, the pressure drop and the drag on individual particles increase,
and eventually the particles start to move and become suspended in the fluid. The terms
‘fluidization’ and ‘fluidized bed’ are used to describe the condition of fully suspended
particles, since the suspension behaves like a dense fluid.
Fluidized beds are used extensively in the chemical process industries, particularly for the
cracking of high-molecular-weight petroleum fractions. Such beds inherently possess
excellent heat transfer and mixing characteristics. These are devices in which a large surface
area of contact between a liquid and a gas, or a solid and a gas or liquid is obtained for
achieving rapid mass and heat transfer and for chemical reactions.
The fluidized bed is one of the best known contacting methods used in the processing
industry, for instance in oil refinery plants. Among its chief advantages are that the particles
are well mixed leading to low temperature gradients, they are suitable for both small and
large scale operations and they allow continuous processing. There are many well established
operations that utilize this technology, including cracking and reforming of hydrocarbons,
coal carbonization and gasification, ore roasting, Fisher-Tropsch synthesis, coking,
aluminium production, melamine production, and coating preparations. Nowadays, you will
find fluidized beds used in catalyst regeneration, solid-gas reactors, combustion of coal,
roasting of ores, drying, and gas adsorption operations. The application of fluidization is also
well recognized in nuclear engineering as a unit operation for example, in uranium extraction,
nuclear fuel fabrication, reprocessing of fuel and waste disposal.
When a fluid is admitted at the bottom of a packed bed of solids at a low flow rate, it passes
upward through bed without causing any particle motion. If the particles are quite small, flow
in the channels between the particles will be laminar and the pressure drop across the bed will
be proportional to the superficial velocity (Vo) and for turbulent situations, pressure drop
across the bed increase nonlinearly with the increase in the superficial velocity. As the
velocity is gradually increased, the pressure drop increases, but particles do not move and the
bed height remains the same. At a certain velocity, the pressure drop across the bed
counterbalances the force of gravity on the particles or the weight of the bed, and any other
further increase in velocity causes the particles to move and the true fluidization begins. For a
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
4
high enough fluid velocity, the friction force is large enough to lift the particles. This
represents the onset of fluidization once the bed is fluidized pressure drop across the bed
remains constant, but the bed height continues to increase with increasing flow.
Figure 1 Fluidization regimes
In order to determine the pressure drop through a fixed bed for any flow condition, the Ergun
equation (1952) can be used:
dp is the size of particles (µm)
L is the height of the bed (m)
µ is the viscosity of sir (N/m2.s)
U is the average superficial velocity (m/s)
ϵ is the bed voidage or porosity
ρ is the density of air/water (kg/m3)
∆P is the pressure drop across the bed (N/m2)
The average Reynolds number based on superficial velocity which is given by,
If the Reynolds number is less than 10 then it is laminar flow and is greater than 2000 it is
turbulent flow. The rest of the values lie in the transition regime. If the flow rate of air/water
Q is measured in litres, A is the bed cross-sectional area and U is the superficial velocity in
m/s, then
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
5
Theoretically at incipient fluidization (the stage in the fluidized bed where the force on the
solid is enough to balance the weight of the solid material),
∆P is in mm of manometer
The pressure drop at fluidization can also be predicted by the equation,
ρp is the particle density (kg/m3)
ρ is the fluid density (kg/m3)
g is the gravitational force (m/s2)
Minimum fluidization velocity
Umf, the minimum fluidizing velocity, is frequently used in fluid-bed calculations and in
quantifying one of the particle properties. This parameter is best measured in small-scale
equipment at ambient conditions. The correlation given below can then be used to back
calculate dp. This gives a particle size that takes into account effects of size distribution and
sphericity. The correlation can then be used to estimate Umf at process conditions. If Umf
cannot be determined experimentally, use the expression below directly.
Assumption: - Consider the uniform particle size.
Remf = (1135.7 +0.0408Ar) 0.5
- 33.7 (Wen and Yu correlation for particles dp> 100 µm)
/Re mffpmf Ud
23 / gdAr fsfp (Ar is the Archimedes Number)
For particles of dp < 100 µm, Baeyens and Geldart (1977) can be used,
5. Experimental procedure
1. The height of the static bed Z1 i.e. when there is no flow of water/air (porosity 1) was
noted.
2. The flow of air/water in the column is started and the flow rates from the rotameter
were noted.
3. The corresponding bed heights and pressure drop values were noted.
4. The flow rates were increased steadily and similar data were collected at different
intervals.
5. 6 to 8 readings of flow rates were varied and reading were taken.
6. Steady state flow rate of water was ensured at each point.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
6
6. Observations and calculations
Particle size = 8 mm
Porosity = 0.6
Inside diameter of the column (D) = 0.055m
Cross-sectional area of fluidized column
= 0.002375 m²
Density of water ρ (at T0C) = 1000 kg/m
3
Viscosity of water µ (at T0C) = 0.798*10
-3 kg/m-s
Density of air = 1.1687 kg/m3
Viscosity of air = 1.8633x10-5
Pa.s
Velocity V (m/s) = volumetric flow rate of water / cross section area of column
Initial height of static bed in the column (Z1)
Porosity of the fluidized Bed: If Z1 and 1 are the height and porosity of the static bed and Z2
and 2 are the height and porosity of fluidized bed, the
)1(
)1(
2
112
ZZ (Total volume of column equal to total volume of solid)
Z2 = 2 Z2 = Z1 (1- 1)
Z2 - Z1 (1- 1) = 2 Z2
2 = Z2 - Z1 (1- 1) / Z2
Note: Keep the observation tables for air and water separately. The sample calculations
for the same should be shown separately.
Obs No. Height of
Bed (Z2)
Volumetric
Flow rate of
water/air in
m³/s
Velocity(v)
m/s
Porosity
()
Pressure
drop (P) NRe
7. Results & Discussions
References:
1. Warren, L McCabe, Smith, J C , and Harriott, P, Unit Operations of Chemical
Engineering, 6th
edition, McGraw Hill, New Delhi, India, 2000.
2. Kunii, Levenspeil O, Fluidized Engineering, Robert E Krieger Publishing Company,
Huntington, New York, 1977
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
7
EXPERIMENT NO. 1(b)
FLOW THROUGH PACKED BED (AIR & WATER)
1. Aim
a) To plot Modified Reynolds’s No. (NRe,m) vs. Modified friction factor (f) on a log-log
graph
b) To verify Ergun’s equation
2. Apparatus
Stop watch, Graduated cylinder, packing as Hollow rings of Glass, Manometer, beakers etc.
3. Theory
A packed bed is a hollow tube, pipe, or other vessel that is filled with a packing material. The
packing can be randomly filled with small objects like Raschig rings, Pall rings or else it can
be a specifically designed structured packing. Packed column is a pressure vessel that has a
packed section. In general, packed towers are used for bringing two phases in contact with
one another and there will be strong interaction between the fluids in this case between solid
and fluid. As the fluid passes through the bed, it does so through the voids presents in the
bed. The voids form continuous channels throughout the bed. The flow may be laminar
through some channels and turbulent in other channels.
Just as with straight pipes, Ergun relates the flows and pressure drops to a Reynolds Number
and friction factor respectively. The Reynolds number for packed beds, Rep , depends upon
the controlled variable i.e. Superficial velocity Vo and the system parameters ρ, ε, μ, and Dp
and is defined as (Bird et. al., 1996),
Dp is the equivalent spherical diameter of the particle, V0 is the superficial velocity defined as
the volumetric flow rate divided by the cross-sectional area of the column, ρ is the fluid
density, ε is the dimensionless void fraction defined as the volume of void space over the
total volume of packing, and μ is the fluid viscosity.
The friction factor, fp, depends upon V0 and the pressure drop, ΔP, and system parameters,
and is defined as (Bird et al., 1996)
P = Pressure drop in kg/cm2
= porosity
L = effectively length of the bed, cm
V = Superficial-fluid velocity, based on empty cross-section of pipe, m/sec
= density of the fluid
= viscosity of fluid
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
8
4. Working principle
Figure 1 Schematic of Packed Bed Column
The packed column shown above is filled with packings, in our case the packing is Raschig
glass rings. Now, in this the water is passed through the bottom of column and the flow
happens through the packing thus creating friction , this friction leads to pressure drop in the
column which is measured by the manometer attached to the two ends of packed column.
Also, the flow here is regulated by the rotameter attached to the column. An increase in flow
increases the friction and thus leads to an increase in pressure drop.
5. Procedure
a. Water/air was allowed to flow from bottom to top in a packed bed.
b. Flow of water/air is regulated to vary the flow rate.
c. The corresponding pressure drop values were noted by means of the manometer for 6
to 8 different rates of flow of fluid.
d. The flow rate values were noted and it was ensured that the steady state flow rates
have been achieved.
6. Observations
Inside diameter of the tube = 50 mm
Volume of each particle = 1.57x10-6
m3
Surface area of the particle = 0.000628 m2
Porosity of the bed = 0.3
Effective length of packing = 750 mm
Temperature of fluid = ambient
Manometer fluid, Hg = 13,534 kg/m³
Density of water ρ (at T0C) = 1000 kg/m
3
Viscosity of water µ (at T0C) = 0.798*10
-3 kg/m-s
Density of air = 1.1687 kg/m3
Viscosity of air = 1.8633x10-5
Pa.s Manometer Reading h (metres)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
9
S.
No.
Volumetric
flow rate of
water. Q
m3/sec
Manometer
reading.
Hgofmh )(
Superficial Velocity of
water = Vo (Q /Cross
sectional area of the
column m/s)
Pressure drop/length
2/)(
mNL
mgh
L
P
Note: Calculate friction factor and modified Reynolds No. and plot on a log-log graph
separately for air and water. The observation columns and sample calculations for both
of them should be shown separately.
Calculations
Certain assumptions are carried out before calculating the Friction factor and Reynolds
number. First, we assume that there is no channeling in the packed bed. Channeling occurs
when the fluid flowing through the packed bed finds a “preferred path” through the bed. We
also assume that the diameter of the packing is much smaller than the diameter of the column
as well. The maximum recommended particle diameter is one-fifth of the column diameter.
We assume that velocity, particle diameter and void fraction behaves as a bulk behavior and
hence we can use an average values.
Initially, we calculate diameter of the particle,
DP =
Calculate friction factor as,
and modified Reynolds number as,
7. Results and Discussion
Modified Reynold’s number, friction factor are calculated accordingly to the changes in
variables affecting and Ergun’s equation is verified.
References: a) Bird, R. Byron, Transport Phenomena. Madison, Wisconsin: John Wiley & Sons,
1996.
b) Geankoplis, Christie J., Transport Process and Unit Operations. 4th ed., New Jersey:
Prentice Hall, 2003.
c) Ergun, Sabri, “Fluid Flow through Packed Columns.” Chemical Engineering
Progress, Vol. 48, No 2. , 89-94 , 1952.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
10
EXPERIMENT NO. 2(a)
LOSSES DUE TO PIPE FITTINGS, SUDDEN ENLARGEMENT &
CONTRACTION
1 Aim
To determine the loss co-efficient for following sections
(a) Sudden expansion
(b) Sudden contraction
(c) Tee – junction
(d) Pipe bend
(e) Elbow
2. Apparatus
FHP (Fractional Horse Power) pump driven pipe system consisting of elbow bend, Tee-
junction, sudden enlargement and contraction, manometer with tapping into pipe for head
readings, sump and discharge tanks, stopwatch.
3. Theory
In Hydraulic Engineering practice, it is frequently necessary to estimate the head loss
incurred by a fluid as it flows along a pipeline. For example, it may be desired to predict the
rate of flow along a proposed pipe connecting two reservoirs at different levels. Or it may be
necessary to calculate what additional head would be required to double the rate of flow
along an existing pipeline.
Loss of head is incurred by fluid mixing, which occurs at fittings such as bends or valves, and
by frictional resistance at the pipe wall. Where there are numerous fittings and the pipes are
short, the major part of the head loss will be due to the local mixing near the fittings. For a
long pipeline, on the other hand, skin friction at the pipe wall will predominate.
Loss of head due to change in cross-section, bends, elbows, valves and fittings of all types
fall into the category of minor losses in pipe lines. In long pipe lines the friction losses are
much larger than these minor losses and hence the latter are often neglected. But, in shorter
pipelines their consideration is necessary for the correct estimate of losses.
When there is any type of bend in pipe, the velocity of flow changes, due to which the
separation of the flow from the boundary and also formation of eddies, takes place. Thus the
energy is lost. The losses of head due to bend in pipe:
g
VKh LL
2
2
The minor losses in contraction can be expressed as:
g
VKh LL
2
2
1
The minor losses in enlargement can be expressed as:
g
VVKh LL
2
)( 2
21
Where, hL = minor loss or head loss
KL = Loss coefficient
V = velocity of fluid.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
11
V1 = velocity of fluid in pipe of small Diameter.
V2 = velocity of fluid in pipe of large Diameter.
4.Experimental set-up
The apparatus consist of a ½” smooth and sharp bends and elbow, a sudden expansion from
½” to 1”, sudden contraction from 1” to ½” and ½” ball valve, gate valve, tee fitting and pipe
union joint. Pressure tapings are provided at inlet and outlet of these fittings at suitable
distance. A differential manometer fitted in the line gives pressure loss due to fittings. Supply
to the pipeline is made through centrifugal pump, which deliver water from sump tank. The
flow of water in pipeline is regulated by means of Control valve & By-Pass valve. Discharge
is measured with the help of measuring tank and stop watch.
4.1 Utilities Required:
a) Power supply: Single Phase, 220 Volts, 50 Hz, 5 Amp with Earth.
b) De-mineralized Water.
c) Drain.
d) Space required: 1.6m x 0.6m
Schematic Diagram for Losses due Pipe Fittings,
Sudden Enlargement & Contraction Apparatus
5 Experimental procedure:
a) Close the drain valves provided.
b) Fill Sump tank ¾ with clean water and ensure that no foreign particles are there.
c) Close all flow control valves given on the water line, pressure taps of manometer
connected to different pipe -fittings and open by-pass valve.
d) Now switch on the main power supply (220 Volts AC, 50 Hz) and start the pump.
e) Operate the flow control valve to regulate the flow of water in the desired test section.
f) Open the pressure taps of manometer of related test section, very slowly to avoid the
blow of water on manometer fluid.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
12
g) Now open the air release valve provided on the manometer, slowly to release the air
in manometer. When there is no air in the manometer, close the air release valves.
h) Adjust water flow rate in desired section with the help of control valve and record the
manometer reading.
i) Measure the flow of water, discharged through desired test section, using stop watch
and measuring tank.
j) Repeat same procedure for different flow rates of water, operating control valve and
by-pass valve.
k) When experiment is over for one desired test section, open the By-Pass Valve fully.
Then close the flow control valve of running test section and open the Control valve
of secondly desired test section.
l) Repeat same procedure for the 9 selected test sections of the two bends, elbow,
contraction, expansion, tee and union joint and both gate and ball valves.
m) When experiment is over, close all manometers pressure taps first, switch off pump,
and switch off power supply to panel.
6 Observation & Calculations
6.1 Specification:
Sudden Enlargement : From 16.5mm to 27mm
Sudden Contraction : From 27mm to 16.5mm.
Bend : 1/2"
Elbow : 1/2"
Ball valve : 1/2"
Gate valve : 1/2"
Tee joint : 1/2"
Union joint : 1/2"
Water Circulation : FHP Pump.
Flow Measurement : Using Measuring Tank with Piezometer, Capacity 40 Ltrs.
Sump Tank : Capacity 80 Ltrs.
Stop Watch : Electronic.
Control Panel Comprises of: Standard make On/Off Switch, Mains Indicator, etc.
6.2 Formulae:
(a) Discharge:
100*
*
t
RAQ ---------------- (1)
(b) Velocity:
1
1a
QV (Velocity in ½” pipe) ---------------- (2)
2
2a
QV (Velocity in 1” pipe) ---------------- (2a)
(c) Loss of Head (for Contraction):
g
VKh LL
2
2
1 ---------------- (3)
(d) Loss of Head (for Expansion):
CKg
VVKh LLL
2
)( 2
21 ---------------- (4)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
13
(e) Experimental loss of head
100
6.13*hhL --------------- (5)
(f) Loss Co-efficient:
2
1
2
V
ghK LL ---------------- (6)
6.3 Data:
A = Area of measuring tank = 0.1m2
s = Specific gravity of Hg = 13.6
g = Acceleration due to gravity = 9.81 m/sec2
d1 = Dia. of smaller pipe = 0.0165 m
d2 = Dia. of larger pipe = 0.027m.
a1 = Cross-sectional area of Small Dia. pipe = 2.14 x 10-4
m2
a2 = Cross-sectional area of Large Dia. pipe = 5.73 x 10-4
m2
6.4 Observation Table:
S.
No.
Type of Fitting Pressure
Difference, h
(cm)
Rise of water level in
measuring tank R (cm)
Time taken for R
(sec.)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
6.5 Calculation Table:
S.
No
Discharge,
Q
Velocity,
V1
Velocity,
V2
Loss of Kinetic
Energy, C
Loss of
head
hL
Loss
coefficient K L
6.6 Nomenclature: Q = discharge, m
3/s
V1 = velocity of fluid in pipe of Small Diameter (m).
V2 = velocity of fluid in pipe of Large Diameter (m).
a1 = Cross-sectional area of Small Dia. pipe
a2 = Cross-sectional area of Large Dia. pipe
KL = loss coefficient.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
14
h = pressure difference, m
hL = head loss, m
R = Rise of water level in measuring tank (m).
t = Time taken for R (sec.).
7. Result &discussion
8. Conclusion
9. Precaution & maintenance instructions:
a) Do not run the pump at low voltage i.e. less than 180 Volts.
b) Never fully close, the delivery line and by-pass line valves simultaneously.
c) Always keep apparatus free from dust. To prevent clogging of moving parts, run
pump at least once in a fortnight.
d) Frequently Grease/Oil the rotating parts, once in three months. Always use clean
water.
e) It apparatus will not in use for more than one month, drain the apparatus completely,
and fill pump with cutting oil.
f)
9.1 Troubleshooting:
a) If pump gets jam, open the back cover of pump and rotate the shaft manually.
b) If pump gets heat up, switch off the main power for 15 minutes, avoid closing the
flow control valve, and by pass valve simultaneously during operation.
References:
a) McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical Engineering”,
4th
ed., McGraw Hill, NY, 1985.
b) Coulson, J.M., Richardson, J.F., “Coulson & Richardson’s Chemical Engineering
Vol. - 1”, 5th
ed., Asian Books ltd., ND, 1996.
c) Brown, G.G., “Unit Operations”, 1st ed., CBS, ND, 1995.
d) Foust, A.S., et. al., “Principles of Unit Operations”, 2nd
ed., John Wiley, NY, 1980.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
15
EXPERIMENT NO. 2(b)
LOSSES DUE TO PIPE FRICTION
1. Aim To determine the losses due to friction in pipes and friction factor for Darcy - Weisbach
equation
2. Apparatus
FHP (Fractional Horse Power) pump driven pipe system consisting of Galvanized Iron (GI)
pipe of ½”, 1” and Stainless Steel (SS) pipe of ½” diameter, manometer with tapping into
pipe for head readings, sump and discharge tanks, stopwatch.
3. Theory
When a fluid is flowing through a pipe, it experiences some resistance due to which some of
the energy is lost. This loss of energy in the pipelines comes under major energy losses and
minor energy losses. In long pipelines, the friction losses are much larger than the minor
losses and hence, the latter are often neglected. The losses due to friction in the pipelines are
known as major energy losses. The friction in the pipeline is due to a viscous drag between
the stream bands of fluid. The stream bands adjacent to the solid surface are always at rest
relative to the wetted surface. The viscous drag is due to the molecular attractions between
the molecular of the fluid.
It is found that the total friction resistance to fluid flow depends on the following:
1. The area of the wetted surface
2. The density of the fluid
3. The surface roughness
4. It is independent of the fluid pressure
5. It increase with the square of the velocity
It depends on a frictional co-efficient. The loss of head in pipe due to friction is calculated
from Darcy-Weisbach equation which has been given by:
Where:
h f = loss of head due to friction
f = Co-efficient of friction
L = distance between pressure point
V = mean velocity of fluid
d = diameter of pipe
g = Acceleration due to Gravity
4. Experimental setup The apparatus consist of three pipes of varying diameters and materials for which common
inlet connection is provided with control valve to regulate the flow, near the down stream end
of the pipe. Pressure tapings are taken at suitable distance apart between which a manometer
is provided to study the pressure loss due to the friction. Discharge is measured with the help
of measuring tank and stopwatch.
d 2g
LV f 4h
2
f
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
16
Schematic Diagram for Friction in Pipe Lines Apparatus
4.1 Utilities Required
a) Power supply: Single Phase, 220 Volts, 50 Hz, 5 Amp with Earth.
b) De-mineralized Water Supply.
c) Drain.
d) Space required : 1.6m x 0.6m
5. Experimental procedure a) Close the drain valves provided.
b) Fill Sump tank ¾ with clean water and ensure that no foreign particles are there.
c) Close all flow control valves given on the water line, pressure taps of manometer
connected to different pipe -fittings and open by-pass valve.
d) Now switch on the main power supply (220 Volts AC, 50 Hz) and start the pump.
e) Operate the flow control valve to regulate the flow of water in the desired test section.
f) Open the pressure taps of manometer of related test section, very slowly to avoid the
blow of water on manometer fluid.
g) Now open the valve provided on the manometer, slowly to release the air in
manometer. When there is no air in the manometer, close the valves.
h) Adjust water flow rate in desired section with the help of control valve and record the
manometer reading.
i) Measure the flow of water, discharged through desired test section, using stop watch
and measuring tank.
j) Repeat same procedure for different flow rates of water, operating control valve and
by-pass valve.
k) When experiment is over for one desired test section, open the By-Pass Valve fully.
Then close the flow control valve of running test section and open the Control valve
of secondly desired test section.
l) Repeat same procedure for different flow rates of water, operating Control Valve and
By-Pass valve.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
17
m) When experiment is over, close all manometers pressure taps first, switch off pump,
and switch off power supply to panel.
6. Observation & calculation
6.1 Specification
Pipes (3 Nos.) : Material GI of ½” & 1” diameter.
SS of ½” diameter
Pipe Test Section : Length 1.1 m for each Pipe
Water Circulation : FHP Pump.
Flow Measurement : Using Measuring Tank with Piezometer, Capacity,
40 Ltrs.
Sump Tank : Capacity 80 Ltrs.
Stop Watch : Electronic.
Control Panel Comprises of:
Standard make On/Off Switch, Mains Indicator, etc.
Tanks will be made of Stainless Steel.
The whole set-up is well designed and arranged in a good quality painted structure.
6.2 Formulae
1. Head losses,
1
100 W
mf
hh
, m of water.
2. Co-efficient of Friction:
2
f
V
gd
L 4
2hf
3. Discharge (Q):
smt
AxRQ /
100*
3
4. Velocity of Fluid:
sma
QV /
6.3 Data:
Area of measuring tank, A = 0.1m2
Sp. gravity of Hg = 13.6
Acceleration due to gravity, g = 9.81m/sec2
Inside Diameter of Pipe, d
For GI pipe (1”) = 0.027 m
For GI pipe (1/2”) = 0.016.5 m
For SS pipe (1/2”) = 0.016 m
Cross-section area of pipe, a
For GI pipe (1”) = 5.70 x 10-4
m2
For GI pipe (1/2”) = 2.14 x 10-4
m2
For SS pipe (1/2”) = 2.01 x 10-4
m2
Distance between pressure points, L = 1.1 m each for all pipes
6.4 Observation Table: (for For GI pipe 1”, GI pipe 1/2”, and SS pipe 1/2”)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
18
Extent of
Valve open
Pressure difference
h (cm)
Rise of water level in
measuring Tank R (cm)
Time taken, t
(sec.)
½ Open
Full Open
6.5 Calculation Table:
Extent of Valve
open
Pressure
head, hf
(m)
Discharge,
Q
(m3/s)
Velocity of
Fluid, V
(m/s)
Fanning Friction
factor, f
½ Open
Full Open
6.6 Nomenclature:
A = Area of measuring tank
a = Cross-section area of pipe
d = Inside Diameter of Pipe
g = Acceleration due to gravity
h = manometer reading, cm
hf = Pressure head of water (m)
R = Rise of water level in measuring Tank (m)
t = Time taken for R (sec)
L = distance between two points
7. Result & discussion
8. Precautions
1. Do not run the pump at low voltage i.e. less than 180 Volts.
2. Never fully close the Delivery line and By-Pass line Valves simultaneously.
3. Always keep apparatus free from dust.
4. To prevent clogging of moving parts, Run Pump at least once in a fortnight.
5. Frequently Grease/Oil the rotating parts, once in three months.
6. Always use clean water.
7. If apparatus will not in use for more than one month, drain the apparatus completely,
and fill pump with cutting oil.
8.1 Troubleshooting:
1. If pump gets jam, open the back cover of pump and rotate the shaft manually.
2. If pump gets heat up, switch off the main power for 15 minutes and avoid closing the
flow control valve and by pass valve simultaneously during operation.
References e) McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical Engineering”,
4th
ed, McGraw Hill, NY, 1985.
f) Foust, A.S., et. al., “Principles of Unit Operations”, 2nd
ed., John Wiley, NY, 1980.
g) Coulson, J.M., Richardson, J.F., “Coulson & Richardson’s Chemical Engineering Vol.
- 1”, 5th
ed., Asian Books ltd., ND, 1996.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
19
EXPERIMENT NO. 2(c)
DRAG COEFFICIENT
1. Aim & Apparatus
To verify Stoke’s law and to study the variation of the drag coefficient with Reynolds number
(Re) for sphere.
Experimental setup of 3 cylinders filled with three different liquids – demineralised water,
glycerine and hydraulic oil, spherical balls, measuring scales and stopwatch.
2. Theory
When a body moves through any fluid, it experiences a resistance, which acts in a direction
opposite to that of the motion of the body. This resistance is called the drag force (FD) and it
depends on the size of the body, velocity with which it moves and the viscosity of the fluid.
According to stoke, the drag force acting on a sphere moving through a fluid due to its weight
is given by the following expression:
FD = 3πµU₀Dp (i)
Where Dp is the diameter of sphere, µ is the viscosity of fluid, and U₀ is called the terminal
fall velocity. Terminal velocity is defined as the velocity attained by a body in falling through
a fluid at rest, when the drag force on the body is equal to the submerged weight of the body.
For equilibrium condition in the case of a freely falling sphere through a liquid, drag force
plus the buoyant force must be equal to the weight of the sphere and is given by the
expression
(ii)
Where Fg is the drag force, g is acceleration due to gravity (9.8 m/sec2), ρp is density of
spherical particle, and ρf is the density of fluid stream.
The drag coefficient predicted by Stoke’s law is given by the expression
, where
(iii)
where ν is the kinematic viscosity of fluid stream (m2/sec). Thus, coefficient of drag CD varies
with Reynolds number.
Experiments have shown that Eq. (ii) holds well for Re < 0.2, and the sphere is falling in an
infinite fluid. If the fluid is not infinite in extent but is confined within a container (finite
dimensions), then the resistance to motion is increased, and in such a case the modified value
of drag coefficient, as given by the following expression, should be used:
CD =
, (1+2.1
) (vi)
Where D is the smallest lateral dimensions of the container and D is the diameter of sphere.
Also the observed fall velocity U is corrected in Eq. (iii) by using the following expression in
order to get the fall velocity corresponding to infinite fluid medium:
Corrected velocity, U₀ = U (1+2.4
)
Where, D is the diameter of the container.
3. Experimental set-up
The set-up consists of three transparent vertical cylinders of diameter 100 mm and height 1
m. A hopper with a valve is provided at the bottom of the cylinder to collect the spheres. The
cylinder is supported by four vertical posts and fixed to a MS table. A vertical scale is fixed
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
20
on the surface of a cylinder. The cylinders are filled with fluids of varying viscosities such as
glycerine, hydraulic oil and water.
4. Experimental procedure
1. Measure the diameters of spheres and note down their materials.
2. Determine the mass of the spheres on electronic balance.
3. Mark two lines on the cylinder for measurement of the vertical distance (L) for the
determination of terminal velocity. The upper line should be at a depth of 100 mm or
more from the free surface so that the terminal velocity is achieved.
4. Hold the sphere with a finger and a thumb and bring it up to the fluid level. Leave the
sphere gently (wet the sphere before dropping it).
5. Note down the time taken by the sphere in falling through distance L.
6. Repeat steps (4) and (5) for other diameters of spheres (Set 1).
7. Repeat steps (4) and (6) for spheres of other material (Set 2).
Fig 1: Stoke’s Apparatus
5. Observations and calculations
5.1 Specification:
Liquid in the cylinder =
Mass density of liquid, ρf = 1261kg/m³ (glycerol),
1080kg/m³ (hydraulic oil),
1000kg/m³ (water)
Mass density of sphere = 2070 kg/m3
Kinematic viscosity of liquid at T 20°C, v = 1.006x10-6
m²/s (water),
1.180x10-6
m²/s (glycerol)
1.25*10-4
m2/s (hydraulic oil)
Diameter of cylinder, D = 87mm
Liquid 2 Liquid 3 Liquid 1
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
21
Distance of fall, L =
Diameter of sphere = 0.819cm
Time of falling for sphere (t) = ____ sec
Terminal Velocity (U) (Length/time for fall) = ______ (m/sec)
5.2 Observation Table:
S.No Fluid type Length of liquid column (m) Sphere falling time (s)
1. Water
2. Glycerol
3. Hydraulic Oil
5.3 Calculation Table:
Fluid
type
Terminal
velocity
Corrected
terminal
velocity
Reynolds
number
Discharge
coefficient
Corrected
Discharge
coefficient
Fg FD
6. Result & discussions
Plot a log-log graph of CD (corrected discharge coefficient) vs. NRe (Reynolds number)
7. Conclusion
8. Precautions
The sphere needs to be dropped from the centre of the cylinder.
Extreme care should be taken while taking out the sphere from the cylinder to avoid
loss of excess fluid.
Wet the sphere with the specific fluid before dropping it in the cylinder.
References:
h) McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical Engineering”,
7th
ed., McGraw Hill, NY, 2005.
i) W.L Badger & J.T. Banchero., “Introduction to Chemical Engineering”, 26th
reprint,
McGraw Hill, NY, 2011.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
22
EXPERIMENT NO. 3(a)
BERNOULLI’S THEOREM
1. Aim & Objective
To experimentally verify Bernoulli equation for fluid flow in horizontal pipe.
2. Apparatus
FHP pump run setup consisting of 4 rectangular tanks, horizontal pipe section, 8 piezometric
tubes with measuring scales, stopwatch.
3. Theory
Energy of a Liquid in Motion
The energy, in general, may be defined as the capacity to do work. Though the energy exists
in many forms, yet the following are important from the subject point of view:
a) Potential Energy
b) Kinetic Energy, and
c) Pressure Energy.
Potential Energy of a Liquid in Motion
It is the energy possessed by a liquid particle, by virtue of its position. If a liquid particle is Z
meters above the horizontal datum (arbitrarily chosen), the potential energy of the particle
will be Z meter-kilogram per kg of liquid. Potential head of the liquid, at that point, will be Z
meters of the liquid.
Kinetic Energy of a Liquid Particle in Motion:
It is the energy, possessed by a liquid particle, by virtue of its motion or velocity. If a liquid
particle is flowing with a mean velocity of v meter per second, then the kinetic energy of the
particle will be v2/ 2g m-kg per kg of liquid. Velocity head of the liquid, at that velocity, will
be v2/ 2g meter of the liquid.
Pressure Energy of a Liquid Particle in Motion:
It is the energy, possessed by a liquid particle, by virtue of its existing pressure. If a liquid
particle is under a pressure of p kg / m2, then the pressure energy of the particle will be p/w
m-kg per kg of liquid, where w is the specific weight of the liquid
Total Energy of a Liquid Particle in Motion:
The total energy of a liquid particle, in motion, is the sum of its potential energy, kinetic
energy and pressure energy. Mathematically,
Total Energy,
w
p
g
vZE
2
2
m-kg/ kg of liquid
BERNOULLI’S EQUATION:
It states, “For a perfect incompressible liquid, flowing in a continuous stream, the total
energy of a particle remains the same; while the particle moves from one point to another.”
This statement is based on the assumption that there are no losses due to friction in pipe.
Mathematically,
w
p
g
vZE
2
2
= Constant --------- (1)
Bernoulli Equation:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
23
---------- (2)
This is the basic from of Bernoulli equation for steady incompressible inviscid flows. It may
be written for any two points 1 and 2 on the same streamline as
--------- (3)
The constant of Bernoulli equation, can be named as total head (ho) has different values on
different streamlines.
-------- (4)
The total head may be regarded as the sum of the piezometric head h* = p/(ρg) + z and the
kinetic head v2/2g.
Bernoulli equation is arrived from the following assumptions:
a) Steady flow - common assumption applicable to many flows.
b) Incompressible flow - acceptable if the flow Mach number is less than 0.3.
c) Frictionless flow - very restrictive; solid walls introduce friction effects.
d) Valid for flow along a single streamline; i.e., different streamlines may have different
ho.
e) No shaft work - no pump or turbines on the streamline.
f) No transfer of heat - either added or removed.
Range of validity of the Bernoulli Equation:
Bernoulli equation is valid along any streamline in any steady, inviscid, incompressible flow.
There are no restrictions on the shape of the streamline or on the geometry of the overall
flow. The equation is valid for flow in one, two or three dimensions.
Modifications on Bernoulli equation:
Bernoulli equation can be corrected and used in the following form for real cases.
Where 'q' is the work done by pump and 'w' is the work done by the fluid and h is the head
loss by friction.
4. Experimental Set-up
The apparatus is made from transparent acrylic and has both the convergent and divergent
sections. Water is supplied from the constant head tank attached to the test section. Constant
level is maintained in the supply tank. Piezometric tubes are attached at different distance on
the test section. Water discharges to the discharge tank attached at the far end of the test
section and from there it goes to the measuring tank through valve. The entire setup is
mounted on a stand.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
24
Figure 1: Schematic diagram of experimental setup
5. Experimental procedure
a) Fill the sump tank with water.
b) Before starting the pump, make sure that the bypass valve is fully open and the
discharge valve is closed.
c) Switch ON the Pump.
d) Flow control valve to the supply tank is opened and bypass valve is closed slowly
and simultaneously. Keep drain valve of the discharge tank fully open.
e) After we get steady height of liquid in the supply tank adjust the drain valve on
the discharge tank so as to get steady level there also.
f) Collect the predetermined quantity of water in the measuring tank and measure
the time required for the same.
g) Also record the height of liquid in each of the piezometric tube.
6. Observations
Sr. No.
Height. diff. in
measuring tank
(m)
H1
H2
ΔH
Volume (m3) V
Time (sec) T
Vol. Flow rate
(m3/sec)
Q
pie
zom
e
tric
tub
e
posi
tion
1
H1=P1/w(m)
v1 = Q/A1
v12/ 2g (m)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
25
Total Head
2
H2=P2/w(m)
v2 = Q/A2
v22/ 2g (m)
Total Head
3
H3=P3/w(m)
v3 = Q/A3
v3 2/ 2g (m)
Total Head
4
H4=P4/w(m)
v4 = Q/A4
v42/ 2g (m)
Total Head
5
H5=P5/w(m)
v5 = Q/A5
v5 2/ 2g (m)
Total Head
6
H6=P6/w(m)
v6 = Q/A6
v6 2/ 2g (m)
Total Head
7
H7=P7/w(m)
v7 = Q/ A7
v7 2/ 2g (m)
Total Head
8
H8=P8/w(m)
v8 = Q/ A8
v82/ 2g (m)
Total Head
Calculations:
Length of the test section = 0.4 m
Piezo tube 1 at 0.05 m c/s area A1 = 0.000961 m2
Piezo tube 2 at 0.085 m c/s area A2 = 0.00053 m2
Piezo tube 3 at 0.115 m c/s area A3 = 0.000314 m2
Piezo tube 4 at 0.18 m c/s area A4 = 0.000572 m2
Piezo tube 5 at 0.240 m c/s area A5 = 0.000854 m2
Piezo tube 6 at 0.300 m c/s area A6 = 0.001256 m2
Piezo tube 7 at 0.355 m c/s area A7 = 0.00166 m2
Piezo tube 8 at 0.40 m c/s area A8 = 0.00215 m2
Cross Sectional Area of Measuring Tank (Am) = 0.09 m2
Height Difference in measuring tank (H) = H1- H2
= m
Volume Collected (V) = H * Am
= m3
Volumetric Flow rate (Q) = V / T
= m3/s
Linear Point Velocity (vi) = Q/ Ai
= m/ sec
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
26
Velocity head at point – 1 = [vi2 / (2*g)]
= m
Total Head at point –1 = Static Head + Velocity Head
= Hi + vi2 / (2*g)
= m
Check for all the points that sum of velocity head and pressure head is almost constant. Here
potential energy is not being considered as the test section lies in one horizontal plane only.
7. Result:
Draw graph of static head, velocity head, and total head Vs distance of the piezometric tubes.
8. Conclusions
9. Precautions
References
(a) McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical
Engineering”, 7th
ed., McGraw Hill, NY, 2005.
(b) W.L Badger & J.T. Banchero., “Introduction to Chemical Engineering”,
26th
reprint, McGraw Hill, NY, 2011.
(c) C.J. Geankoplis., “Transport Processes and Separation Process
Principles”, 4th
ed., PHI, 2009.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
27
EXPERIMENT NO. 3(b)
VENTURIMETER, ORIFICEMETER & ROTAMETER CALIBRATION
1. Aim & Objective
a) To determine the co-efficient of discharge through Venturimeter & Orificemeter.
b) To calibrate the Rotameter
2. Theory
VENTURIMETER:
A Venturimeter consists of;
1. An inlet section followed by a convergent cone.
2. A Cylindrical Throat.
3. A gradually divergent cone.
The inlet section of the Venturimeter is of the same diameter as that of the pipe,
which is followed by a convergent cone. The convergent cone is a short pipe, which tapers
from the original size of the pipe to that of the Throat of the Venturimeter. The Throat of the
Venturimeter is a short parallel side tube having its cross-sectional area smaller than that of
the pipe. The divergent cone of the Venturimeter is gradually diverging pipe with its cross-
sectional area increasing from that of the Throat to the original size of the pipe. At inlet
section & Throat of the Venturimeter, pressure taps are provided.
ORIFICEMETER:
An Orificemeter consists of a flat circular plate with a circular hole called Orifice,
which is concentric with the pipe axis. An orifice plate is a thin plate with a hole in the
middle. It is usually placed in a pipe in which fluid flows. When the fluid reaches the orifice
plate, the fluid is forced to converge to go through the small hole; the point of maximum
convergence actually occurs shortly downstream of the physical orifice, at the so-called vena
contracta point. As it does so, the velocity and the pressure changes. Beyond the vena
contracta, the fluid expands and the velocity and pressure change once again. By measuring
the difference in fluid pressure between the normal pipe section and at the vena contracta, the
volumetric and mass flow rates can be obtained from Bernoulli's equation.
ROTAMETER:
The Rotameter is a variable – area meter that consists of an enlarging transparent tube
and a metering “float” (actually heavier than the liquid) that is displaced upward by the
upward flow fluid through the tube. The tube is graduated to read the flow directly. Notches
in the float cause it to rotate and thus maintain a central position in the tube. The float is an
indicating element, and greater the flow rate, the higher the float rides in the tube.
3. Experimental set up
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
28
Schematic Diagram for Venturimeter, Orificemeter & Rotameter Apparatus
Flow Diagram of Venturimeter Flow Diagram of Orificemeter
4. Experimental procedure
VENTURIMETER & ORIFICEMETER:
Starting Procedure:
a) Clean the apparatus and make All Tanks free from Dust.
b) Close the drain valves provided.
c) Fill Sump tank ¾ with Clean Water and ensure that no foreign particles are there.
d) Close all Flow Control Valves given on the water line and open By-Pass Valve.
e) Close all Pressure Taps of Manometer connected to Venturimeter & Orificemeter.
f) Ensure that On/Off Switch given on the Panel is at OFF position.
g) Now switch on the Main Power Supply (220 Volts AC, 50 Hz).
h) Switch on the Pump.
i) Operate the Flow Control Valve to regulate the flow of water in the desired Test
Section.
j) Open the Pressure Taps of Manometer of related Test section, very slowly to avoid
the blow of water on manometer fluid.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
29
k) Now open the Air release Valve provided on the Manometer, slowly to release the air
in manometer.
l) When there is no air in the manometer, close the Air release valves.
m) Adjust water flow rate in desired section with the help of Control Valve.
n) Record the Manometer reading.
o) Measure the flow of water, discharged through desired test section, using Stop Watch
and Measuring Tank.
p) Repeat Steps the same procedure for different flow rates of water, operating Control
Valve and By-Pass valve.
q) When experiment is over for one desired test section, open the By-Pass Valve fully.
Then close the flow control valve of running test section and open the Control valve
of secondly desired test section.
CALIBRATION OF ROTAMETER:
a) Close the ball valves provided in the Venturimeter and Orificemeter pipelines.
b) Open the ball valve provided in the Rotameter pipeline.
c) Now switch on the main power supply and switch on the pump.
d) Set the flow rate with the help of by pass and flow control valves provided in
Rotameter pipeline.
e) Measure the discharge with the help of measuring tank and stopwatch.
f) The actual discharge, verify the set value of Rotameter.
g) Repeat the same procedure for different flow rates.
Closing Procedure:
a) When experiment is over, close all Manometers Pressure Taps first.
b) Switch off Pump.
c) Switch off Power Supply to Panel.
5. Observation
For venturimeter & orificemeter
OBSERVATION TABLE:
S.No. Pressure
difference, h
(cm)
Rise of Water level in
Measuring Tank, R
(cm)
Time taken for R, t
(sec.)
Average Co-efficient of Discharge:
For rotameter
OBSERVATION TABLE:
S.No. Rotameter
Reading in
LPH, Qth
Rise of Water level in
Measuring Tank, R
(cm)
Time taken for R, t
(sec.)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
30
FORMULAE:
For both Venturimeter & Orificemeter:
1. Head losses,
1
100 W
mhH
, m of water ------------------- (1)
2. Theoretical discharge (Qt):
2
2
2
1
21 2
aa
gHaaQt
, m
3/s ------------------- (2)
3. Actual discharge (Qa):
100*t
AxRQa , m
3/s ------------------- (3)
4. Co-efficient of discharge (Cd):
Cd = Qa/Qt ------------------- (4)
For Rotameter:
5. Actual discharge:
10003600100*
xxt
AxRQa , m
3/s ------------------- (5)
DATA:-
H= Head loss
h = Pressure difference (m)
A = 0.1 m2
ρm = Density of manometric fluid = 13600 kg/ m3
ρW = Density of working fluid = 1000 kg/ m3
g = Acceleration due to Gravity = 9.81 m/sec2
For Venturimeter:
d1 = Dia. at inlet of the venturimeter = 28mm = 0.028m
d2 = Dia. at throat of the Venturimeter = 14mm = 0.014m
a1 = d1 2/4 cm
2 Area at inlet of Venturimeter = 6.157 * 10
-4 m
2
a2 = d2 2/4 cm
2 Area at throat of Venturimeter = 1.539* 10
-4 m
2
For Orificemeter:
d1 = Dia. at inlet of Orificemeter = 28mm. = 0.028m
d2 = Dia. of Orifice Plate = 14mm. = 0.014m
a1 = d12/4 Area at inlet of Orificemeter = 6.157 * 10
-4m
2
a2 = d22/4 m
2 Area of Orifice Plate = 1.539* 10
-4 m
2
6. Result and discussion
For Venturimeter and Orificemeter
S. No. Actual discharge Qa
, m3/s
Theo. Discharge Qt ,
m3/s
Cd = Qa/Qt
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
31
For Rotameter
S. No. Rotameter Reading in Qth, m3/s Theo. Discharge Qt,
m3/s
7. Conclusion
8. Precaution
1. Do not run the pump at low voltage i.e. less than 180 Volts.
2. Never fully close the Delivery line and By-Pass line Valves simultaneously.
3. Always keep apparatus free from dust.
4. To prevent clogging of moving parts, Run Pump at least once in a fortnight.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
32
EXPERIMENT NO. 3(c)
FLOW THROUGH HELICAL COIL
1. Aim
To determine the critical Reynolds number of a fluid flowing through the helical coil.
To determine the friction factor for flow of water through helical coil.
2. Apparatus
Helical coil experiment set up, Stop watch, Vernier Caliper
3. Theory
Helical coils are used widely in processing industries for cooling and heating applications
since the centrifugal forces experienced by the fluid acts to promote contact with the channel
wall, thereby tending to insure good contact with the wall, and an enhanced heat transfer
Some of their main advantages over straight tubes are high heat and mass transfer
coefficients, and space economy in terms of area per unit volume.
Helical coils are used for heating or cooling in process tanks. When a fluid flows through a
curved tube, centrifugal force acting upon the various elements of fluid moving with different
velocities causes secondary circulation. Secondary flow results in higher heat transfer
characteristics. Further, secondary flow stabilizes the laminar flow leading of a higher critical
Reynolds number for transition from laminar to turbulent flow.
The use of helically coiled exchangers continues to increase. Applications include liquid
heating/cooling, steam heaters, vaporizers, cryogenic cooling and vent condensing. Listed
below are the details for standard services in which helical exchangers warrant consideration.
Seal Coolers, Condensers, Cryogenic Vaporizers, Compressor Inter- and After-Coolers.
4. Experimental Procedure
a) With the discharge valve closed, switch ON the pump.
b) Slowly open the discharge valve and note down the manometer reading.
c) Note down the time taken for 1 cm raise in the discharge tank.
d) Repeat the same procedure for different flow rates of water.
5. Observation
d = Inner diameter of helical pipe = 0.932×10-2
m
v = velocity of water in pipe (m/sec)
µ = dynamic viscosity of water at 25 oC (0.890 ×10
-3 Ns/m
2)
A = cross-sectional area of coil = m2
H1 = one side manometer reading.
H2=other side manometer reading.
H2 – H1 = difference in manometer reading.
V= volume of water collected.
T= time in seconds
OBSERVATION TABLE:
S. No H1 H2
H1-H2
V(m3)
T(sec)
Q (m3/s)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
33
1
2
3
4
6. Calculation
Volume collected is calculated by measuring tank, V = l * b * height
(Units in meter) = m3
Flow rate Q = V/T = m3 /sec
Velocity v = Q/A = m/sec
On the basis of velocity we can find Reynolds number,
Re = ρ * v * d
ρ = density of water = 1000 kg/m3
v= velocity
d = inner diameter of coil
= dynamic viscosity of water
Calculation for fanning friction factor
F = (∆p/ ρ g) * (D/L) * (2g/v2)
∆p=pressure difference in manometer
g =9.81 m/s2
D = overall diameter of coil = 0.235 m
H = overall height of coil = 0.35 m
N = No. of turns = 14
R =D/2
LENGTH OF COIL L = N2 * R
2
9R + 10 H
Put the value of L in the above equation and find out value of friction factor of helical coil.
7. Result and Conclusion The critical Reynolds number of the fluid flowing through the coil was found to be
_______.
The friction factor for flow of water through helical coil was found to be ______
8. Precaution
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
34
EXPERIMENT NO. 4(a)
STUDY OF PITOT TUBE – AIR
1. Aim
To determine the velocity profile for the flow of air through a circular pipe using Pitot Tube.
2. Objective
To measure the velocity at different points in the flow.
3. Theory
A pitot tube is a device to measure the point velocities in the flow field of a fluid. It generally
consists two concentric tubes arranged parallel to the flow .The outer tube is perforated at one
end with small holes in its wall, which are perpendicular to the flow direction and lead to the
annular space. The annular space is otherwise sealed except for a manometer lead on the
other end .The inner tube has a small opening at one end (the same end in which holes are
there in the outer tube) parallel to the flow and pointed in the direction opposite to the flow
direction. The other end of the tube has a manometer lead. The two tubes are connected to
two limbs of a manometer through the manometer leads. At equilibrium there is no fluid
within the pitot tube. The annular space serves to transmit the static pressure. The flowing
fluid is brought to rest at the entrance of the inner tube, and this tube transmits the impact
pressure (or stagnation pressure) equivalent to the kinetic energy of the flowing fluid at that
position. If and are the stagnation pressure measured by the inner and outer tubes
respectively, the point velocity, , at a given position can be obtained from the Bernoulli
equation, by neglecting the frictional losses, as
u0 = √ {2(Ps-P0)/ℓf} = √ {2gh(ℓm-ℓf)/ℓf}
Where ℓf and ℓm are the densities of the process fluid and the manometric fluid respectively,
h is the difference in the level of the manometric fluid in the two limbs of the manometer,
and g is the acceleration due to gravity. Thus by changing the position of the pitot tube the
local velocities in the flow field can be obtained. The velocity profile at a given cross section
of the pipe is obtained by moving the pitot along the diameter of the pipe. By knowing the
point velocities at a given cross section, the volumetric flow rate, Q, can be determined
Q = 0∫D/2
2ᴫru0dr
Where D is the pipe diameter, and r is the radius at which u0 is measured.
4. Requirements
Pipe line with provision for supply of air, pitot tube, inclined manometer.
5. Procedure
1. Start the flow of air by switching on the blower.
2. Divide the pipe diameter in 9 equal parts to fix the radial position at which the point
velocities are to be determined.
3. Keep the pitot tube at the radial position.
4. Once the flow steadies (indicated by unchanging or slightly fluctuating level
difference in the manometer), record the level difference in the manometer.
5. Record the ambient temperature (taken same as the air temperature).
6. Repeat step 4 by moving the pitot tube at the radial determined in step 2.
6. Observations
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
35
Ambient temperature (T) =
Air density at T = kg/m³
Density of manometric liquid at T = kg/ m³
S.No. r,mm h,mm
7. Formula
1)Point velocity, u0
u0 = √ {2gh(ℓm-ℓf)/ℓf}
2)Volumetric flow rate,Q
Q = 0∫D/2
2ᴫru0dr
8. Results and discussion
1. Calculate the point velocities at different radial positions.
2. Plot the point velocity versus the radial position.
3. Calculate the volumetric flow rate from the point velocities .
9. Conclusions
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
36
STUDY OF PITOT TUBE - WATER
1. Aim
To determine the velocity profile across the cross section of pipe for the flow of water
using Pitot tube and thereby determine the co-efficient of Pitot tube for different flow rates.
2. Objective
To measure the velocity at different points in a pipe for different flow rates.
3. Theory
It is a device used for measuring the velocity of flow at any point in a pipe. It is based on the
principle that if the velocity of flow at a point becomes zero, there is increase in pressure due
to the conversion of the kinetic energy into pressure energy.
The Pitot tube consists of a capillary tube, bent at right angle. The lower end, which is bent
through 90, is directed in the upstream direction. The liquid rises up in the tube due to
conversion of kinetic energy into pressure energy. The velocity is determined by measuring
the rise of liquid in the tube.
When a Pitot tube is used for measuring the velocity of flow in a pipe or other closed conduit
the Pitot tube may be inserted in the pipe as shown in figure. Since a Pitot tube measures the
stagnation pressure head (or the total head) at its dipped end. The pressure head may be
determined directly by using piezometeric readings between the Pitot tube and pressure
taping at the pipe surface. Consider two points (1) and (2) at the same level in such a way that
point (2) is just at the inlet of the Pitot -tube and point (1) is far away from the tube. At point
(1) the pressure is p1 and the velocity of the stream is v1. However, at point (2), is called
stagnation point, the fluid is brought to rest and the energy has been converted to pressure
energy. Therefore the pressure at (2) is p2, the velocity v2 is zero and since (1) and (2) are in
the same horizontal plane, so z1 = z2.
Applying Bernoulli’s equation at points (1) and (2)
g
v
w
p
g
v
w
p
22
22
2
2
11
v2 = 0
w
p
w
p
g
v 1212
2
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
37
w
p
w
pgv 12
1 2
gHv 21
This is theoretical velocity.
Actual velocity gHCv vact21
4. Requirements
Pitot tube : Material SS/copper of compatible size fitted
with scale.
Test Section : Material Clear Acrylic, compatible to 1” dia
Pipe.
Water Circulation : FHP Pump.
Flow Measurement : Using Measuring Tank,
Capacity 40 Ltrs.
Sump Tank : Capacity 70 Ltrs.
Stop Watch : Electronic.
Control Panel Comprises of: Standard make On/Off Switch, Mains Indicator, etc.
5. Experimental set-up The apparatus consists of a Pitot tube made of SS and fixed below a pointer gauge. The
pointer gauge is capable to measure the position of Pitot tube in transparent test section. The
pipe has a flow control valve to regulate the flow. Piezometric tubes are provided to
determine the velocity head. A pump is provided to circulate the water. Discharge is
measured with the help of measuring tank and stopwatch
6. Experimental procedure
Starting Procedure:
1. Clean the apparatus and make Tank free from Dust.
2. Close the drain valves provided.
3. Fill Sump tank ¾ with Clean Water and ensure that no foreign particles are there.
4. Close all Flow Control Valves given on the water line and open By-Pass Valve.
5. Ensure that On/Off Switch given on the Panel is at OFF position.
6. Now switch on the Main Power Supply (220 Volts AC, 50 Hz).
7. Switch on the Pump.
8. Operate the Flow Control Valve to regulate the flow of water through orifice.
9. Adjust water flow rate to desired rate with the help of flow Control Valve.
10. Set the Pitot tube at the center of test section
11. Record the piezometric reading and measure the discharge with the help of measuring
tank and stop watch.
12. Now move the Pitot tube up and down at the same flow rate and note the piezometric
readings to find out the velocity at different points in pipe.
13. Calculate the co – efficient of Pitot tube from actual and theoretical velocities and plot
the velocities at different points inside the pipe.
14. Repeat the same procedure for different flow rates of water, operating Control Valve,
and By-Pass valve.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
38
Closing Procedure:
1. When experiment is over Switch off Pump.
2. Switch off Power Supply to Panel.
3. Drain water from all tanks with the help of given drain valves.
FORMULAE
1. Discharge,
t
RAQ
* ----------------------- (1)
2. Actual Velocity,
a
Qvact ----------------------- (2)
3. Theoretical velocity
ghvth 2 ------------------------ (3)
4. Co – efficient of Pitot tube,
th
actv
v
vC ------------------------- (4)
5. Velocity at any point,
ghCv v 2
7. Observation table
S.No. Pressure head at
different points on up
side
Pressure
head at
center
Pressure head at
different points on down
side
R(cm) t(sec)
8 mm 6 mm 4 mm 0 4 mm 6 mm 8 mm
1.
2.
3.
CALCULATION TABLE
S.
No.
Cv v8 v6 v4 v0 v4 v6 v8
1.
2.
3.
DATA
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
39
A = 0.1 m2
a = 0.0006157 m2
g = 9.81 m/ s2
NOMENCLATURE
A = Area of measuring tank.
a = Cross section area of test section
R = Rise of water level in measuring tank.
h = Piezometric difference
CV = Co efficient of Pitot tube
g = Acceleration due to gravity
va = actual velocity of fluid.
Q = discharge at outlet.
t = time for R.
8. Result & discussions
Calculate the point velocities at different radial positions.
Calculate the co-efficient of Pitot Tube for different flow rates.
Plot the point velocity versus the radial position.
9. Conclusion
10. Precautions
1. Do not run the pump at low voltage i.e. less than 180 Volts.
2. Never fully close the Delivery line and By-Pass line Valves simultaneously.
3. Always keep apparatus free from dust.
4. To prevent clogging of moving parts, Run Pump at least once in a fortnight.
5. Frequently Grease/Oil the rotating parts, once in three months.
6. Always use clean water.
7. If apparatus will not in use for more than one month, drain the apparatus completely,
and fill pump with cutting oil.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
40
EXPERIMENT NO. 4(b)
STUDY OF REYNOLDS APPRATUS
1. Aim
To study the flow regime for liquid flow in a pipe, and to find the critical Reynold's number.
2. Objective
To find the volumetric flow rate corresponding to various flow regimes.
3. Theory
Osborne Reynolds (1883) demonstrated different flow regimes when a fluid flows through a
pipe. These regimes are: laminar, turbulent and transition or intermediate regimes. For a
given pippe and fluid, laminar flow exists at low velocity characterized by ordered sliding
past of liquid layer over one another without lateral mixing; while turbulent flow is found at
high velocity in which the flow pattern is random and there is intense lateral mixing in the
fluid. In between these two extremes, a transition flow regime is observed in which the flow
alters between laminar and turbulent flows. Reynolds’s found that the nature of flow depends
on the diameter of the pipe, and viscosity, density and average velocity of the fluid; and these
factors can be combined into one dimensionless group, called the Reynolds’s number, the
magnitude of which would indicate the flow regime. The Reynolds number, Re is defined as
Re = Du/µ = Du/v
Where D = pipe diameter, u= fluid velocity, ρ= fluid density, µ = fluid viscosity, and v =
kinematic viscosity.
Physically, Reynolds number is interpreted as the ratio of the inertial force to viscous force
acting on the fluid. In general, D and v represent some characteristic dimension of the flow
domain and characteristic velocity of the fluid. Thus laminar flow exists at small Reynolds
number, and turbulent flow at large Reynolds number.
The minimum Reynolds number at which laminar flow disappears is called the critical
Reynolds number. The value of critical Reynolds number depends on the geometry of the
flow domain (circular or rectangular pipe, open or closed channel, flat plate etc.) and flow
configuration (flow around a bluff body, in packed bed etc.)
4. Requirements Reynolds apparatus, water source, dye, measuring cylinder, stop watch.
5. PROCEDURE
1. Fill in the tank with water, and the dye- chamber with dye.
2. Note the water temperature.
3. Start the water flow and maintain a small flow rate, enough to fill the whole pipe
cross section.
4. Once the flow stabilizes, start the dye injection. The injection rate should be just
enough to give a clear visible streak of the dye.
5. Observe the pattern of the dye streak. The dye should flow in a straight line.
6. Increase the water in small and equal increments, and observe the dye streak.
7. Repeat step 6 until some undulations commence in the streak. Note the corresponding
volumetric flow rate of water, which is the critical Reynolds number. Appearance of
the undulations signifies the initiation of the intermediate or transition flow.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
41
Note At this point the undulations will be unstable so that there will be some portion
of the dye streak which will be undulating and some portion which will
not.
8. Keep increasing the flow rate of the liquid further until at one point there is found a
complete dispersion of the dye (indicated by the liquid getting colour through the
cross section) just as it comes out of the injection needle. This point shows the
conversion to a fully turbulent regime.
9. Note the corresponding the volumetric flow rate.
6. Observations Temperature of the liquid =
Pipe diameter = m
S.No Flow Regime Volume of water collected Time taken
1 Laminar
2 Transition
3 Fully Turbulent
Volumetric flow rate corresponding to start of the Laminar flow = m³/s
Volumetric flow rate corresponding to start of the transition flow = m³/s
Volumetric flow rate corresponding to fully turbulent flow = m³/s
Liquid density at observed temperature = kg/m³
Liquid viscosity at the observed temperature = kg/m.
7. Results and discussion 1. Calculate the Reynolds number corresponding to the transition flow and turbulent
flow.
The liquid velocity is calculate as u = 4Q/ π D², Where Q is the volumetric flow
rate.
2. Compare the critical Reynolds number and the Reynolds number for transition to fully
turbulent flow observed with those reported in the literature. Discuss the possible
sources of discrepancy, if any.
8. Conclusion
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
42
EXPERIMENT NO. 5 (a)
CENTRIFUGAL PUMP CHARACTERISTICS
1. AIM
Study and analysis of centrifugal pump characteristics.
2. Objectives 1. To study the operating characteristics of a centrifugal pump.
2. To study the operating characteristics of two centrifugal pumps operated in series and in
parallel.
3. Theory Pumps are the fluid moving machineries which increase the mechanical energy of the fluids
to be displaced. The energy increase may be used to increase the velocity, the pressure or the
elevation of the fluids. A large number of pumps, differing widely in principle and
mechanical construction, have been developed to meet a wide variety of operating conditions.
For selection of pumps for a specific application requires the knowledge of operating
conditions of the system and applicability of different available pumps.
The mechanical energy of the liquid is increased by centrifugal action. Centrifugal pumps
are classified as single suction and double suction pumps depending upon the suction from
either one side or from both sides respectively.
In a single suction centrifugal pump the liquid enters through a suction connection concentric
with the axis of a high-speed rotary element called the impeller, which carries radial vanes
integrally cast in it. Liquid flows outward in the spaces between the vanes and leaves the
impeller at a considerably greater velocity with respect to the ground than at the entrance to
the impeller. In a properly functioning pump the space between the vanes is completely filled
with liquid flowing without cavitation. The liquid leaving the outer periphery of the impeller
is collected in a spiral casing called the volute and leaves the pump through a tangential
discharge connection. In the volute, the velocity head of the liquid from the impeller is
converted into pressure head. The power is supplied to the fluid by the impeller and is
transmitted to the impeller by the torque of the drive shaft, which usually is driven by a
direct-connected motor at constant speed, commonly at 1750 rpm. Another common type
uses a double-suction impeller, which accepts liquid from both sides. Also, the impeller itself
may be a simple open spider, or it may be enclosed or shrouded.
4. Experimental Set up
4.1. Requirements Centrifugal pump test rig, bucket, watch.
4.2. Schematic Diagram of Experimental Setup The schematic diagram of the experimental setup is shown below:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
43
V8
V-Notch
Measuring Tank
Sump Tank
P1
P2
P3
P4
V1
V2
V4
V3 C1 C2
V5
OPERATION OPEN CLOSE
SINGLE PUMP : V1, V4, V5 V2, V3, V8, V9
SERIES : V1, V2, V5 V3, V4, V8, V9
PARALLEL : V1, V3, V4, V5 V2,V8,V9
5. Experimental Procedure First, prime the pump by pouring water through valve V8. Subsequently, the following
sequence of operations are to be carried out:
5.1. Calibration of V-Notch
1. Measure the width of the V-notch at the top and depth of the V-notch.
2. Fill the storage tank with water.
3. Open valves V1, V2 and V5, and close valves V3, V4 & V9.
4. Start running the pumps.
5. Fill the channel with water until water starts spilling over the notch to the outlet.
6. Stop the water supply by closing the bench supply valve (V5) with the pump in running
condition.
7. Allow the water above the crest height to spill over the notch.
8. When the water level is at the level of the crest of the notch, bring the point gauge exactly
to the water surface, and note the reading (say R1) on the longer scale which coincides
with the “zero” of the shorter scale. (This is the datum level for subsequent height-
measurements when the water flows in the channel.)
9. Open valve V5 completely and wait for the level (or head) of water in the channel to
stabilize.
10. Bring the point gauge to the surface of the water by rotating the knob attached to the
scale, and note the reading (say R2) on the longer scale that coincides with the “zero” of
the shorter scale.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
44
11. Collect the water in the bucket for an arbitrary but known duration, and determine the
flow rate of water by dividing the volume (or mass) of water collected by the time of
collection.
12. The difference (R2-R1) is called the head which is related to the volumetric flow rate by
the following equation:
2
5
2tan15
8hgCQ d
; Where, h = R2-R1
13. Adjust the water flow rate at seven different values from the maximum to zero flow rate
in the channel by manipulating valve V5 and determine the water flow rate and the
corresponding head.
14. Calculate the discharge coefficient (Cd) in each case, and take the arithmetic average of
these values as the Cd of the notch.
5.2. Pump Characteristics (Single Pump)
1. After carrying out the steps 1 to 3 mentioned in “Calibration of V-Notch”, open the valve
V5 fully.
2. Note the RPM of the pump from the control panel.
3. Note the gage pressure on the outlet line (P4 in the figure) and on the inlet line (P1 in the
figure). The difference of the readings in P4 and P1 is the head delivered by the pump.
4. Note the power supplied to the pump from the display on the control panel by pressing
the appropriate button (labeled W).
5. Note the head of the V-notch.
6. Repeat steps 2 to 5 for seven different flow rates of water spanning the whole range of
flow rate up to zero flow by manipulating V5.
5.3. Pump Characteristics (Pump in Series)
1. Fully open the valves V1, V2 and V5, and close valves V3 and V4.
2. Note the RPM of the pump from the control panel.
3. Note the gage pressure on the outlet line (P4 in the figure) and on the inlet line (P1 in the
figure).
4. Note the power supplied to the pump from the display on the control panel by pressing
the appropriate button (labeled W).
5. Note the head of the V-notch.
6. Repeat steps 2 to 5 for seven different flow rates of water spanning the whole range of
flow rate up to zero flow by manipulating V5.
7. Repeat steps 1 to 6 for three different RPMs.
5.4. Pump Characteristics (Pump in Parallel)
1. Fully open the valves V1, V3, V4 and V5, and close valve V2.
2. Note the RPM of the pump from the control panel.
3. Note the gage pressure on the outlet line (P4 in the figure) and on the inlet line (P1 in the
figure).
4. Note the power supplied to the pump from the display on the control panel by pressing
the appropriate button (labeled W).
5. Note the head of the V-notch.
6. Repeat steps 2 to 5 for seven different flow rates of water spanning the whole range of
flow rate up to zero flow by manipulating V5.
7. Repeat steps 1 to 6 for three different RPMs.
6. Observations
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
45
6.1. Calibration of V-Notch Width across the top of the V-notch =
Depth of the V-notch =
Initial point gauge reading at zero flow rate (R1) =
S No Point gauge
reading, R2
Head of
the V-notch
(R2 – R1)
Amount of
Water collected
Duration of
collecting water
6.2 Pump Characteristics*
1. RPM =
2. Initial point gauge reading at zero flow rate (R1) =
3. Length of Pipe in single pump operation =
4. Length of Pipe in series operation =
5. Length of Pipe in parallel operation =
6. Elevation =
7. Diameter of the suction pipe =
8. Diameter of the discharge pipe =
S No Point gauge
Reading, R2
Head of
The V-notch
Gauge pressure reading Power to the
pump P1 P4
* Make separate tables for different configurations (single/series/parallel) of the pumps and for different RPMs.
7. Model Calculations
For steady incompressible flow of a liquid of density , the developed head is given as
fhZZg
VV
g
PPH
)(
212
2
1
2
212
(1)
where subscripts 1 and 2 signify the values at the suction and delivery ports of the pump; P
is the pressure; V is the velocity; Z is the elevation; and hf is the friction head (that is, the
frictional losses) in the line between the suction and delivery ports. hf is given by
g
VK
D
Lfh ff
24
2
(2)
where f is the friction factor, L is length of the pipe, D is the diameter of the pipe, Kf is the
loss factor for fittings. Friction factor (f) depends on roughness and type of flow
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
46
(laminar/turbulent) and read from friction factor chart. Alternatively, it can be calculated
from the equations:
Re
16
Nf ; for laminar flow
The friction factor for turbulent flow can be calculated by using Colebrook equations (either
implicit form or explicit form) given below:
7.1. Implicit Forms of Colebrook Equation
There are at least three forms of the Colebrook Equation that can be found in current
literature on hydraulics. These are:
fNDf Re
1051.2
7.3log2
1 (3)
fNDf Re
107.182
log274.11
(4)
fD
N
D
f Re
10103.9
1log2log214.11
(5)
where,
f is the Friction Factor and is dimensionless
ε is the Absolute Roughness and is in units of length
D is the Inside Diameter and, as these formulas are written, is in the same units as ε.
NRe is the Reynolds Number and is dimensionless.
Note that ε/D is the Relative Roughness and is dimensionless.
These three equations are referred to as “Implicit” Equations. “Implicit” means that “f”, the
Friction Factor, is “Implied or understood though not directly expressed”2. Simply stated,
the equations ARE NOT in the form of “f = ………”. These are sometimes referred to as
“equivalent” but the results will vary when calculated to the fourth significant digit.
These equations can be solved for “f” given the Relative Roughness (ε/D) and the Reynolds
Number, (NRe), by iteration. Such iterations can be performed using an electronic
spreadsheet. A spreadsheet, “Friction Factor Formulas for Cheresource.xls” is available at
http://www.cheresources.com/colebrook1.shtml presented for demonstration. The
spreadsheet contains four worksheets. The first “Tab” is labeled “Iterations”. The Iterative
solutions are generated by breaking the formulas in two parts, that which is left of the equal
sign and that which is right of the equal sign (See row 20 as an example). The Iteration then
tests values of “f” that will result in the difference between the two sides to be zero or very
close to zero. (A complete explanation was published in the ASHRAE Journal of September,
2002: see Reference 4 for details)
7.2. Explicit Forms of Colebrook Equation
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
47
There are four Explicit forms of Colebrook Equations reported in literature. (Ref: available
on internet at http://www.cheresources.com/colebrook1.shtml). Out of these the Serghide’s
solution is the most accurate one, which is given below:
Serghide’s Solution (see Reference 3 for details).
22 )))2(/()(( ABCABAf (6)
where
)]/12()7.3/[(log2 Re10 NDA
)]/51.2()7.3/[(log2 Re10 NADB
)]/51.2()7.3/[(log2 Re10 NBDC
Serghide can be used across the entire range of the Moody Diagram. Its accuracy is
unparalleled amongst the Explicit Equations evaluated here. It appears to be based on Eqn. 3,
as do all the Explicit Equations presented. There is less deviation between Serghide and Eqn.
3 then there is between Eqn. 3 and either Eqn. 4 or Eqn. 5.
6.0log07.41
Re fNf
; (7)
Eqn. 7 is the von Karman equation for turbulent flow which can be used only if the pipe is
smooth. In our case, the pipe is not smooth and hence this equation cannot be used.
Colebrook equation has to be used.
Power developed by the pump (or the power delivered to the fluid) Pf is given as
gQHPf (8)
where Q is the volumetric flow rate of the liquid.
The mechanical efficiency of the pump is given as
B
f
P
P (9)
where PB is the total power supplied to the pump drive from an external source.
Operating (or performance) characteristics of a pump is commonly illustrated by plots of
actual head developed H, power consumption Pf, and efficiency versus the volumetric flow
rate.
8. Results & Discussion
8.1. Calibration of V-notch
S No Volumetric flow rate Head of the V-notch Cd
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
48
Average Cd =
8.2. Pump Characteristics (RPM = )
S No Volumetric flow
rate
Head developed by
the pump
Power delivered by
the pump Efficiency
1. Plot head, power delivered to the pump, power delivered to the liquid, and efficiency
versus the capacity of the pump (i.e., flow rate of water).
2. Suggest the operating point from the efficiency versus flow rate plot.
9. Conclusions
10. Precautions
Do not run the pump with the delivery valve closed for a long time to avoid damage of the
pump.
References
1. Warren, L McCabe, Smith, J C , and Harriott, P, Unit Operations of Chemical
Engineering, 6th
edition, McGraw Hill, New Delhi, India, 2000.
2. Babu, B.V.,"Pumps: Selection & Trouble Shooting", IPT (Indian Plumbing Today), Vol.
2005 (No. 6), pp. 41-49, November-December, 2005.
3. T.K.Serghide’s implementation of Steffenson’s accelerated convergence technique,
reportedly to have appeared in Chemical Engineering March 5, 1984.
4. Lester, T. “Calculating Pressure Drops in Piping Systems.” ASHRAE Journal Sept.
2002.
EXPERIMENT NO. 5 (b)
RECIPROCATING PUMP CHARACTERISTICS
1. AIM
Study and analysis of operating characteristics of double acting reciprocating pump.
2. Objectives To study the operating characteristics of a double acting piston-type reciprocating pump.
3. Theory A piston pump consists of a cylinder with a reciprocating piston. The fluid is drawn through
an inlet check valve into the cylinder by the withdrawal of a piston and is then forced out
through a discharge check valve on the return stroke. Most piston pumps are double acting
with the liquid admitted alternately on each side of the piston so that one part of the cylinder
is being filled while the other is being emptied. The energy added per unit mass of liquid by
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
49
the pump is termed as the head developed by the pump, which is expressed in length
dimension.
4. Experimental Set up
4.1. Requirements Reciprocating pump test rig, watch.
4.2. Experimental Setup
P2
P1
V1
V2
V3
LL
V4
To Drain
Measuring
Tank
Sump
Tank
5. Experimental Procedure 1. Fill the storage tank with water and ensure that the measuring tank is empty.
2. Open the valve on the delivery line, and allow the flow from the delivery line to drain
directly into the sump tank with the help of the drain valve.
3. Adjust the RPM of the motor to an arbitrary but known value.
4. Note the gauge pressures at the suction and delivery line of the pump.
5. Note the power to the pump from the display on the control panel by pressing appropriate
button.
6. Collect water in the measuring tank for a given duration of time and note the change in
water level in this tank during this period.
7. Repeat steps 2 to 6 for seven different flow rates of water spanning the whole range of
flow rate (excluding zero flow rate) by manipulating the delivery valve.
8. Repeat steps 4 to 7 for three different RPMs.
6. Observations Technical specifications of the pump:
i. Type: Double acting
ii. Power: Connected to 1 HP, 3 phase, 440V AC motor.
iii. Pump bore (diameter): 44.5 mm
iv. Pump stroke: 35 mm
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
50
Inside diameter of the suction pipe =
Inside diameter of the delivery pipe =
RPM =
Length of the suction pipe =
Length of the delivery pipe =
Elevation =
S No
Time of collection
of water in
measuring tank
Change in water
level in the
measuring tank
Gauge pressure
reading Power to
the pump Suction
(P1)
Delivery
(P2)
Note: Make separate tables for different RPMs.
7. Model Calculations
For steady incompressible flow of a liquid of density , the developed head is given as
fhZZg
VV
g
PPH
)(
212
2
1
2
212
(1)
where subscripts 1 and 2 signify the values at the delivery and suction ports of the pump; P is
the pressure; V is the velocity; Z is the elevation; and hf is the friction head (that is, the
frictional losses) in the line between the suction and delivery ports. hf is to be calculated as
described in previous experiment, i.e., centrifugal pump characteristics.
Power developed by the pump (or the power delivered to the fluid) Pf is given as
gQHPf (2)
where Q is the volumetric flow rate of the liquid.
The mechanical efficiency of the pump is given as
B
f
P
P (3)
where PB is the total power supplied to the pump drive from an external source.
Volumetric efficiency (V) of a reciprocating pump is defined as the ratio of the actual
discharge (Q) to the theoretical discharge (Qth). The theoretical discharge is the volume swept
by the piston of the pump per unit time. The difference between the theoretical and actual
discharge of the pump is called the slip.
th
VQ
Q (4)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
51
where Qth for a double acting pump is given by
NLdQ Bth
60
2
42 2
(5)
where dB and L are the bore diameter and length of the stroke of the pump, and N is the speed
of rotation of the crank (attached to the motor) in RPM.
Operating (or performance) characteristics of a pump is commonly illustrated by plots of
actual head developed H, power consumption PB and Pf and efficiency versus the capacity
of the pump (i.e., the volumetric flow rate of liquid).
8. Results & Discussion
RPM =
Theoretical discharge of the pump =
S No Volumetric flow
rate
Head developed
by the pump
Power delivered
by the pump Η ηV
1. Plot head, power delivered to pump, power delivered to the liquid, and mechanical
efficiency versus the capacity of the pump (flow rate of water).
2. Suggest the operating point from the efficiency versus flow rate plot.
9. Conclusions
10. Precautions
Never run the pump with the delivery valve closed.
References
3. Warren, L McCabe, Smith, J C , and Harriott, P, Unit Operations of Chemical
Engineering, 6th
edition, McGraw Hill, New Delhi, India, 2000.
4. Babu, B.V.,"Pumps: Selection & Trouble Shooting", IPT (Indian Plumbing Today), Vol.
2005 (No. 6), pp. 41-49, November-December, 2005.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
52
EXPERIMENT NO. 6 (a)
HEAT PIPE DEMONSTRATOR
1. Aim
To study the performance of heating of heat pipe and compare its working with the best
conductor.
2. Objective
To calculate the thermal conductivity of the given heat pipes.
3. Theory
A heat pipe or heat pin is a heat-transfer device that combines the principles of both thermal
conductivity and phase transition to efficiently manage the transfer of heat between two solid
interfaces. At the hot interface of a heat pipe a liquid in contact with a thermally conductive
solid surface turns into a vapor by absorbing heat from that surface. The vapor then travels
along the heat pipe to the cold interface and condenses back into a liquid - releasing the latent
heat. The liquid then returns to the hot interface through either as capillary action, centrifugal
force, or gravity, and the cycle repeats. Heat pipes are thermal superconductors, due to the
very high heat transfer coefficients for boiling and condensation.
3.1 Working Principle
The heat pipe is a heat-transfer element with extremely high thermal conductivity and large
heat transfer capacity, which accomplishes the heat transfer through the latent heat of phase
change of the working fluid inside the sealed vacuum tube. For the typical gravity heat pipe,
the up end of the heat pipe releases heat, while the working media is condensed into the
liquid. The condensed liquid, with the pull of gravity, will return to the hot side along the
inner wall of the heat pipe and will be heated and vaporized again. In this way, the heat will
be transferred from one end to the other successively by the heat transfer of phase change, the
thermal resistance inside the heat pipe is very small, which results in a larger heat transfer
capacity at a smaller temperature difference.
In terms of the gravity heat pipe, due to its simple structure, single-direction heat
conductivity, and special heat transfer mechanism (the heat exchange between the hot fluid
and the cold one is done outside the heat pipe), the heat transfer can be easily enhanced, the
working fluid is readily evaporated and boiled and the heat pipe is quick to start up the heat-
transfer capability of the heat pipe can rival and even exceed that of stainless steel and
copper. The heat pipe can be used individually or as combinedly. The heat pipe heat
exchanger consisting of heat pipes is characterized by such merits as high heat transfer
efficiency, low flow resistance, compact structure, high reliability, and excellent maintenance
economy, and is widely applied in the space technology, electronic, metallurgical, motive
power, and petroleum and chemical trades.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
53
Fig. Liquid and Vapor pressure distribution along the heat pipe
4. Experimental Set up
4.1. Requirements
The apparatus consist of three different test specimen viz. stainless steel, copper & heat pipe
(Al) which is banded with water cut at the top and heaters at the bottom.
4.2. Schematic Diagram of Experimental Setup
The schematic diagram of the experimental setup is shown below
:
5. Procedure
1. Plug-in socket of control panel & set up instrument in proper position.
2. Fill up the cup provided on each of the pipe with water.
3. Start the main switch of control panel.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
54
4. Increase slowly the input to heater by the dimmerstat starting from 0 volts position
and ampere I changes accordingly.
5. Adjust input so that it correspond out to certain Watts to be calculated (i.e. Q = V *
I) out as maximum by help of dimmerstat by varying Voltage.
6. See that both inputs remain constant throughout the experiment.
7. The steady state condition can be checked by rectal temperature of thermocouple of
1 to 8 zone temperature indicator provided on Control panel out of which 1 to 6
channel temperature Indicator are actually working with 1,2 – Stainless Steel , 3,4 –
Heat Pipe (Al) and 5,6 – Copper material heat pipe.
8. Note down the reading in the all the tube with Time up to which it reaches before
and after steady state as given in observation table.
6. Observations & Calculations
Data given:
1. Length of SS, Copper and Heat pipe (L) :- 300 mm
2. Diameter of pipe (Dp) :- 250 mm
3. Area of pipe (Ap) :- 0.04908 m2
6.1 Observation table for S.S. pipe.
Thermocouple
No.
Thermocouple
Position (mm)
(Before Steady State)
Temperature
(K)
(Before Steady
State)
Temperature
(K)
(At Steady State)
1 50
2 200
6.2 Observation table for Heat pipe.
Thermocouple
No.
Thermocouple
Position (mm)
(Before Steady State)
Temperature
(K)
(Before Steady
State)
Temperature
(K)
(At Steady State)
3 50
4 200
6.3 Observation table for Copper pipe.
Thermocouple
No.
Thermocouple
Position (mm)
(Before Steady State)
Temperature
(K)
(Before Steady
State)
Temperature
(K)
(At Steady State)
5 50
6 200
6.4 Formulae & Calculations
QA = V * I
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
55
QA = - KA * AP *
QA – Power, Watts
V – Voltage Potential, Volts
I – Ampere Current, Ampere
QA - Heat Transfer Rate, Watts
Ap - Area of Pipe, m2
T - Change in temperature from Start to Steady state ,K
x - Change in position of Thermocouple from Start to Steady state (i.e. 50 & 200 mm)
KA - Thermal Conductivity of Material A, W / m . K
For Copper, Heat pipe and Stainless Steel pipe :
KA =
= W / m .K
7. Results
Thermocouple
Position
(mm)
Thermal Conductivity
( W/m K)
SS pipe Heat pipe Copper pipe
50
200
8. Precautions
1. Ensure that the Dimmerstat is at 0 position at before switching on and off the
equipment.
2. Increase the energy input gradually to the heater during initial set-up experimentation.
3. Never use the heater at full wattage for longer period of time.
EXPERIMENT NO. 6 (b)
THERMAL CONDUCTIVITY OF SOLIDS
1. Aim
To measure the thermal conductivity of solids.
2. Objective
(i) To Determination the Overall Thermal Conductivity of Composite wall.
(ii) To check that the Thermal Resistances in Composite wall are connected in series.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
56
3. Theory
Thermal conductivity is defined as the fundamental property of material which gives the
measure of the effectivity of material in transmitting heat through it.
For the measurement of the thermal conductivity K what is required is to have one
dimensional heat flow through the flat specimen, an arrangement for maintaining its faces at
the constant temperature and metering method to measure the heat flow through a known
area.
Knowing the heat input to the central plate heater, the temperature difference across the each
specimen, its thickness and the area, one can calculate the K by the following formula.
K = q * L / [2 * A* ( - )]
Where,
K Thermal Conductivity of the sample, W / m
q Heat flow rate in the specimen, W
A Area of the specimen, m²
Hot side average temperature,
Cold side average temperature
L Thickness of the specimen, m
4. Experimental Set up
4.1. Requirements
Thermal Conductivity Apparatus with composite wall (Mild steel, Hylam (Paper Grade) &
Wood), C clamps
4.2. Schematic Diagram of Experimental Setup
Two sections of composite walls are positioned on either side of the plate heater (Ni-Cr wire
packed in upper and lower mica sheets, 1000 W)
Two thermocouples (2&3) are used to measure the hot face temperature at the upper and
lower heater plate, 4 & 5 are used to measure the temperature at the other end of mild steel
plate (25mm), 6 & 7 to measure temperature at far end of hylam sheet (20 mm) and 8 & 9 for
far end of the wooden plate (12 mm). (see figure). Diameter of the plates is 300 mm
Specimens are held in position by the help of C clamps. The whole assembly is enclosed in
wooden box with one side transparent of visualization.
Voltmeter and Ammeter are used to measure the energy input to the heater. This energy input
to the heater can be varied using Dimmer stat. Digital temperature indicator with selector
switch on the control panel indicates the temperature at different positions in the composite
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
57
wall. Indicator lamp Indicates ON/OFF position of the heater. MCB has been provided to
switch ON/OFF the power to the equipment.
5. Procedure
The specimens are placed on either side of the heating plate assembly uniformly touching
each other. Then predetermined heat input is given to the heater using the Dimmer stat. The
input of the heater (current & voltage) and the thermocouple readings are observed every 5
minutes till a reasonably steady state condition is reached (steady temperature gradient). The
readings are recorded in the observation table. The final steady state values are taken for
calculations.
6.Observations and calculations:
6.1 Observation Table
S.No. Volt.
(V)
Amp.
(A)
T2
( )
T3
( )
T4
( )
T5
( )
T6
( )
T7
( )
T8
( )
T9
( )
6.2 Calculations
Heat transfer Area Perpendicular to Heat Flow,
A = (π /4) * D² = ________ m²
Heat Input Q = V * I = ________ W
Thermal Conductivity for individual specimen,
= (Q * ) / [2 * * ( – ], W/m0C
i = 1, 2 and 3 for MS, Hylam and Wooden Plate respectively.
Where,
= ( + ) / 2 for MS plate, ( + ) / 2 for Hylam Plate, ( + ) / 2 for Wooden
Plate,
= ( + ) / 2 for MS Plate, ( + ) / 2 for Hylam Plate, ( + ) / 2 for Wooden
Plate,
Overall Thermal Conductivity,
= (Q * L) / [2 * A *((( + ) / 2) – (( + ) / 2)))], W / m
Indiviual Thermal Resistance,
Ri= L/KiAi, 0C/W
In Series, Thermal Resistance Rt of the composite wall is given by
RT= ∑ Ri , i = 1, 2 and 3 for MS, Hylam and Wooden Plate respectively.
7. Results Overall thermal conductivity of the material is……. W/m
0C
8. Precautions 1. Ensure that the Dimmer state is at 0 position at before switching on and off the
equipment.
2. Increase the energy input gradually to the heater during initial set-up experimentation.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
58
3. Never use the heater at full wattage for longer period of time.
EXPERIMENT NO. 6 (c)
THERMAL CONDUCTIVITY OF LIQUIDS
1. Aim
To measure of the effectivity of the liquid in transmitting heat through it.
2. Objective
To determine the Thermal conductivity of liquid.
3. Theory
Thermal conductivity is the property of a material to conduct heat. Heat transfers occurs
across materials of high thermal conductivity than across materials of low thermal
conductivity. Thermal conductivity of materials is temperature dependent. For the
measurement of the thermal conductivity K what is required is to have one dimensional heat
flow through the flat specimen, an arrangement for maintaining its faces at the constant
temperature and metering method to measure the heat flow through a known area.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
59
Knowing the heat input to the central plate heater, the temperature difference across the each
specimen, its thickness and the area, one can calculate the K by the following formula.
K = q * L / [A * ( Theater avg – Tsample liquid temp ) ]
where,
K Thermal Conductivity of the sample, W / m C
q Heat flow rate in the specimen, W
A Area of the specimen, m2
TH,av Hot side average temperature, C
TC,av Cold side average temperature, C
L Thickness of the test section, m
Thermal conductivity is important in building insulation and related fields. However,
materials used in such trades are rarely subjected to chemical purity standards.Several
construction materials' ''k'' values are listed below. These should be considered approximate
due to the uncertainties related to material definitions.
The following table is meant as a small sample of data to illustrate the thermal conductivity
of various types of substances.
Some typical thermal conductivity (k values)
Material Thermal
Conductivity
(W·m−1
·K−1
)
Temperature
(K)
Ice 1.6 - 2.2 293
Water 0.32 293
Glycerol 0.29 293
Rubber (92%) 0.16a 303
Alcohols OR Oils 0.1- 0.21 293
Air 0.024 - 0.0262 273-300
Oxygen (O2) 0.0238 293
Nitrogen (N2) 0.0234 - 0.026 293 - 300
4. Experimental Set up
4.1. Requirements
Thermal Conductivity Apparatus with composite wall (Mild steel, Hylam (Paper Grade) &
Wood), C clamps
.
4.2 Description
Test Section (SS 304, 5 mm width, 150 mm diameter) is resting on a heater (500 W, Ni-Cr)
.The heat passing across the test section is removed by the cooling water jacket.
The housing made of Mild Steel has been filled with glass wool to ensure minimum heat loss
to the surroundings.
The total assembly of test section, , main heater and cooling jacket are held in position by the
help of bolts.
Voltmeter and Ammeter are used to measure the energy input to the heater. This energy input
to the heater can be varied using Dimmerstat. Digital Temperature indicator with selector
switch on the control panel indicates the temperature at different positions. Indicator Lamp
indicates ON/ OFF position of the heater. MCB has been provided to switch ON/ OFF the
power to the equipment.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
60
5. Procedure
1. Fill the test section with the liquid whose thermal conductivity is to be measured.
2. Switch ON the Main heater and set the desired heat input through the test section
using Dimmerstat.
3. Start the cooling water supply to the cooling water jacket.
4. Now observe the temperatures T1 to T6 after 15 minutes and note down their values
once they become reasonably constant .
6. Observations and calculations
6.1 Observation Table
Sr.
No
Volt
(V)
Amp.
(A)
T1
(C)
T2
(C)
T3
(C)
T4
(C)
T5
(C)
T6
(C)
1
2
3
4
5
T1= heater temperature
T2= cold water inlet temp to upper plate
T3= hot water outlet temp of upper plate
T4= cold water inlet to lower plate
T5= hot water outlet of lower plate
T6= sample liquid inner temp
T Heater = Heater temperature= T1
Tsample = sample liquid temperature
Diameter of test section = 150 mm
Thickness of test section = 20 mm
6.2 Calculations Heat Transfer Area Perpendicular to Heat Flow,
A = (2 * * r) = ------------------ m
2
Heat Input Q = V * I = ------------ Watt
Thermal Conductivity , K = (Q * L) / [A * (Theater – T 6)] = ----------- W/ m C.
7. Results Thermal conductivity of the material is……. W/m
0C
8. Precautions 1. Ensure that the Dimmerstat is at 0 position at before switching on and off the
equipment
2. Increase the energy input gradually to the heater during initial set-up experimentation
3. Never use the heater at full wattage for longer period of time
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
61
EXPERIMENT NO. 7 (a)
DROPWISE AND FILWISE CONDENSATION
1. Aim:
To determine the inside and outside heat transfer coefficient of Filmwise and
Dropwise condenser.
To study the Dropwise and Filmwise condensation phenomena
2. Apparatus:
Filmwise and Dropwise Condensers enclosed in a Borosilicate Glass Tube with flow control
valves, Steam generator with heating elements, Digital Temperature Indicator with selector
switch, Rotameter.
3. Theory:
Condensation Heat Transfer:
The process of condensation is the reverse of boiling. Whenever a saturated vapor comes in
contact with a surface at a lower temperature, condensation occurs. There are two modes of
condensation; filmwise, in which the condensate wets the surface forming a continuous film
which covers the entire surface and dropwise in which the vapor condenses into small liquid
droplets of various sizes which fall down the surface in a random fashion.
Filmwise condensation generally occurs on clean uncontaminated surfaces. In this type of
condensation the film covering the entire surface grows in thickness as it moves down the
surface by gravity. There exists a thermal gradient in the film and so it acts as a resistance to
heat transfer. In dropwise condensation a large portion of the area of the plate is directly
exposed to the vapor, making heat transfer rates much larger (5 to10 times) than those in
filmwise condensation.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
62
4. Experimental Setup
T4
Apparatus description: The apparatus consist of:
Steam Generator: (8 liter capacity) equipped with 2 kW heater and Pressure Gauge, Manual
Release Valve, Feed Line and Steam Line.
Dropwise Condenser:
MOC: Copper with chrome plating
Dimensions: ID (di) = 16 mm
OD (do) = 19 mm
Length (L) = 170 mm
Filmwise Condenser:
MOC: Copper with Natural finish
Dimensions: ID (di) = 16 mm
OD (do) = 19 mm
Length (L) = 170 mm
Temperature Indicator with Selector Switch measures the Temperature of :
T1 Steam Chamber Temp.
T2 Cooling Water Inet to dropwise condenser
T3 Cooling Water Inet to filmwise condenser
T4 Dropwise Condenser outlet Temp
T5 Filmwise Condenser outlet Temp
T6 Dropwise condensation surface Temp
T7 Filmwise condensation surface Temp
DROPWISE – FILMWISE CONDENSATION APPARATUS
T2-3
T1
T6 T7
T5
STEAM
INLET
WATER
INLET
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
63
5. EXPEIRMENTAL PROCEDURE
a) Fill the steam generator with about 10 – 15 liter of water (preferably soft).
b) Connect supply socket to the mains and switch on the heater.
c) Switch on the heater while keeping the steam line and feed line valves in closed position.
d) Adjust the temperature of the steam near to the 105 – 110 OC.
e) Allow the steam generation to take place.
f) This may take 30 – 40 minutes depending on the initial temperature of the feed water.
g) The pressure of the generated steam will be indicated on the pressure gauge. Note down
the Pressure reading of the steam inlet.
h) Now select the condenser to be tested first and open the ball valve of the same for cooling
water supply.
i) Now start the supply of cooling water in the selected condenser (Dropwise or Filmwise)
j) Depending upon the type of condenser under test Dropwise or Filmwise condensation can
be visualized.
k) If water flow rate is low than steam pressure in chamber will rise and pressure gauge will
read the pressure.
l) If the water flow rate is matched than condensation will occur at more or less at
atmospheric pressure.
m) Process of Dropwise and Filmwise condensation can be easily viewed through the front
glass window of main unit.
n) Note down the inlet temperature of the cooling water, Outlet Cooling water Temperature
as indicated by the DTI.
o) Slowly open the steam line valve and allow the steam to enter the steam chamber.
p) Observe the condensation phenomena and also note down the condenser temperature,
steam inlet temperature.
q) Measure and note the cooling water flow rate through Rotameter provided.
r) Repeat the above procedure for the second type of condenser.
s) Use the wiper provided if the fog/ mist restricts the visualization of the glass vessel
t) At the time of steady state ,the outlet temperature of the water flow inside the tube
becomes constant.
PRECAUTIONS:
a) Do not start heater supply unless water is filled in the test unit.
b) Operate gently the selector switch of temperature indicator to read various temperatures.
c) Increase the temperature gradually of the heater during initial set-up experimentation.
d) Never use the heater at full wattage for longer period of time.
e) Use the proper range of Rotameter.
f) Operate the change over switch of temperature indicator gently from one position to
other, i.e. from 1 to 4 position
6. Observations:
Filmwise Condensation:
Cooling Water Flow Rate (mw): LPM
Temperature:
T1 Steam Temp:
T3 Cooling Water In Filmwise Condenser:
T7 Filmwise Condenser Surface Temp:
T5 Cooling water outlet from film wise condensation
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
64
Dropwise Condensation:
Cooling Water Flow Rate (mw): LPM
Temperature:
T1 Steam Temp:
T2 Cooling Water in Drop wise Condenser:
T6 Drop wise Condenser Surface Temp:
T4 Cooling water outlet from drop wise condensation surface
Calculations: Normally steam will not be pressurized, but the pressure gauge reads some pressure than
properties of steam should be taken at that pressure or otherwise atmospheric pressure will be
taken.
First calculate the heat transfer coefficient inside the condenser under test. For this properties of water are taken at bulk mean temperature of water
i.e. for dropwise condensation mean temp = (T2 + T4) / 2.
Film-wise condensation mean temp = (T3+T5)/2
Following properties are required:
Density of water kg / m3
Kinematic Viscosity m2/ sec
Thermal Conductivity ‘k’ kcal / hr m C
Prandtl Number Pr
Reynolds Number NRe = v di /
Where
v = (mw*4/ * di2) = ( Flow rate/Area)
di = Inner Diameter of Condenser
If this value of NRe > 2100 then flow is turbulent, below this value flow is laminar.
Normally flow will be turbulent in the tube.
Nusselt Number NuD = 0.023 (ReD)0.8
(Pr)0.4
Inside heat transfer coefficient ( hi ) = NuD * k/ di kcal / hr m2 C
Calculate heat transfer coefficient on outer surface of the condenser HO:
For this properties of water are taken at bulk mean temperature of condensate
(Ts + Tw) / 2.
Density of water kg / m3
Kinematic Viscosity m2/ sec
Thermal Conductivity ‘k’ kcal / hr m C
Prandtl Number Pr
Reynolds Number NRe = v di /
Where, Ts Temperature of steam,
T6-7 Temperature of condenser wall (DROPWISE AND FILMWISE)
do outside diameter of condenser
1. ho = 0.725 * 2 * g * k3 / ( Ts - Tw) * do
From these values overall heat transfer coefficient (U) can be calculated,
1/ U = 1 / hi + (di / do) (1 / ho)
U = kcal / hr m2 C
The same procedure can be repeated for another condenser.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
65
Except for some exceptional cases overall heat transfer coefficient for dropwise condensation
will be higher than that of filmwise condensation. Results may vary from theory to some
degree due to unavoidable heat losses from the glass tube walls.
7. Result:
GIVEN DATA:
First calculate the heat transfer coefficient inside the condenser under test. For this properties
of water are taken at bulk mean temperature of water
i.e. (T2 + T4) / 2. Following properties are required:
PHYSICAL PROPERTIES AT WATER MEAN TEMPERATURE
Physical Properties Dropwise Condenser
Filmwise Condenser
Steam Temperature OC Ts 99.3
99.4
Mean Temperature oC Tm(T2+T4 / 2) 35
35
Density of Water kg/m3 993.95
993.95
Viscosity
Kg/ m s µ 0.00073 0.00073
Kinematics Viscosity
m2/ s
0.732*10-6
0.732*10-6
Cooling Water
Flowrate LPM Q 2 2
Vol. Flowrate
m3/s
m 0.000033 0.000033
Velocity
m/s V 0.164 0.164
Thermal Conductivity
kcal / hr m C K 0.537 0.537
Specific Heat
CP 0.997 0.997
Now calculate the heat transfer coefficient outside the condenser under test. For this
properties of condensate are taken at bulk mean temperature of Condenser wall and the Steam
Inlet Temperature i.e. (Tw + Ts) / 2. Following properties are required:
PHYSICAL PROPERTIES AT CONDENSATE MEAN TEMPERATURE
Physical Properties Dropwise Condenser Filmwise Condenser
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
66
Steam Temperature OC T1 99.3 99.4
Mean Tamp 0C
Tm 78.45 82.2
Density of Water kg/m3 971.8 971.8
Viscosity
Kg/ m s µ 0.000355 0.000355
Kinematics Viscosity
m2/ s
0.365*10-6
0.365*10-6
Cooling Water
Flowrate LPM Q 2
Vol. Flowrate
m3/s
m 0.000033
Velocity
m/s V 0.164
Thermal Conductivity
kcal / hr m C K 0.579
Specific Heat
CP 0.997
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
67
EXPERIMENT NO. 7 (b)
UNSTEADY STATE HEAT TRANSFER UNIT
AIM
(1) To study the unsteady state temperature response of finite geometric shapes.
(2) To calculate the value of surface conductance (h).
1. THEORY:
When the temperature at any given point in a system changes with time, the heat transfer is at
unsteady state. The phenomenon of unsteady state heat transfer is widely utilized in industrial
processes, such as the cooling of metal ball bearings. The calculation of heat transfer
coefficients makes it possible, among other things, to predict the amount of time a system
takes to reach steady state conditions.
In this experiment, we want to use a lumped capacity analysis to simplify our
calculations, in which only the effects of convection are significant. This occurs when the
internal resistance is negligible, and the Biot Number, Bi, is less than 0.1 as described in
Equation (1).1
k
hxBi (1)
where k is the thermal conductivity and x is a characteristic dimension of the body obtained
from the volume to area ratio.
Derivation of Lumped-Sum Analysis:
tpxC
h
TT
TT
0
ln (1*)
where x is the relative radius, described by:
A
Vx (2*)
V is the volume of the cylinder and A is the surface area. For a long cylinder this becomes:
2
rx (3*)
Plugging into equation (1*)
trC
h
TT
TT
p
2ln
0
(4*)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
68
trC
h
TT
TT
p
2ln
0
(2)
where Cp is the heat capacity and is the density of the material. T is the temperature of a
large bath, T is the center temperature of the cylinder at time, t, and T0 is the initial center
temperature.
This lumped sum model makes several approximations, including that of an infinite
tank. As discussed in previous reports, this approximation is not valid for the tank in the
Rothfus lab using materials with high internal resistance, such as Plexiglas. However, using
materials with low internal resistance such as those in this experiment, the lumped sum model
is a close approximation. In addition to the approximation of an infinite bath, the h value is
the average value over the entire surface of the cylinder. This introduces a problem of
conduction through the ends of the cylinder, which must be accounted for by using an
appropriate length (L) to diameter (D) ratio2:
2D
L (3)
Using Plexiglas end caps helps to eliminate heat flow through the ends of the cylinders,
making the infinite cylinder approximation more accurate. Using various L/D ratios, it is
possible to test the accuracy of this assumption, which is addressed in this experiment.
In general, the average heat-transfer coefficient on immersed bodies is correlated in terms of
the Nusselt number1:
3/1
PrReNCNN m
Nu (4)
where NPr is the Prandtl number which is constant for this experiment.
The variables C and m are constants based on the Reynolds number. From all previous
reports using similar cylinders, the Reynolds number was found to be within the range of 4 x
103 to 4 x 10
4 corresponding to C=0.683 and m=0.618
3.
DvN Re (5)
where v, , and are properties of water which are constant throughout the experiment.
k
hDN Nu (6)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
69
where k is the thermal conductivity of water, and D is the diameter of the cylinder. From
these equations it can be seen that h will decrease with increased diameter.
382.01
D
Ch
(7)
where C1 is a proportionality constant. This relationship will hold true for infinite cylinders,
but with increasing diameter and constant, finite length, the end effects will become more
apparent, and therefore the Biot number will increase.
While equation (6) contains a relation between the k value of the surrounding water
and the convective heat transfer coefficient, it does not indicate any relationship between the
h value and the thermal conductivity of the material itself. In fact, this equation would imply
that the material has no affect on the heat transfer coefficient, as long as the lumped sum
approximation has been justified, meaning the internal resistance is relatively low. However,
in previous experiments it has been noted that the heat transfer coefficient varies with
changing material properties.4
When the effects of internal resistance are not negligible, the lumped-sum analysis
described above is invalid, and Heisler charts must be used to calculate the convective heat
transfer coefficients. To use these charts, dimensionless numbers are calculated and applied
to a chart with data for objects of varying geometry. In this case, we will use the following
described values and apply them to a Heisler chart (see figure A 4.1 below) to determine the
heat transfer coefficient of a long cylinder.5
21
x
tX (8)
0TT
TTY
(9)
xh
km
(10)
1x
xn (11)
pC
k
(12)
X is a dimensionless number which accounts for the effects of the shape and material, where
k is the solid thermal conductivity, and x1 is the radius of the cylinder. Y is a dimensionless
temperature constant, m is the inverse of the Biot number, relating conductive effects and
convective effects, and n is a relative radius, in which x is the location of the thermocouple.
The results gathered from Heisler charts will be accurate even with significant internal
resistance and are recommended anytime the Biot number is greater than 0.1.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
70
Figure A4.1: Heisler chart.
2. Experimental setup:
In this experiment, the effects of material selection and radius on the heat transfer coefficient,
h, of a solid cylinder were measured.
For this experiment the materials were ordered and were prepared by cutting the appropriate
material into its desired length. Then Sphere & Cylinder were drilled in the centre to a depth
that corresponded to half its length (See Figure A2.1 for an example of how this was done).
A Type J, iron/ constantan, thermocouple was glued into the centre of each cylinder using an
epoxy with a high thermal conductivity. This particular epoxy was chosen because it would
not have any affect on the temperature readings that were obtained from the thermocouple.
In essence, the presence of the epoxy could be ignored. (For more accurate results, the ends
of the cylinders would be sealed with Plexiglas end caps and a two-part epoxy. The epoxy
and Plexiglas acted as an insulator to prevent heat loss from the ends of the cylinders.)
The apparatus consist of a 20 litre SS 304 tank equipped with 1.5 kW heater and a drain
valve. The tank is well insulated from outside to prevent heat losses to the surroundings. The
temperature of the fluid inside the tank can be controlled by the regulator provided on the
tank and is measured using the digital temperature indicator. Two shapes of known geometry
and metals are provided with thermocouples to study the unsteady state heat transfer.
T1 Hot Oil/ Water Bath Temperature
T2 Mild Steel Sphere
T3 Copper Cylinder
Test Body Shape 1:
Geometry = Cylinder
MOC = Copper
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
71
Diameter = 50 mm
Length = 150 mm
Density () = 8900 kg/m3
Specific Heat (Cp) = 0.38 kJ/ kg oC
Test Body Shape 2:
Geometry = Sphere
MOC = Mild Steel
Diameter = 50 mm
Density () =
Specific Heat (Cp) =
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
72
3. Schematic diagram:
4. Procedure:
A hot water bath is used . This water bath provides a constant temperature environment for
the experiment to be conducted .The test body was placed in the ambient temperature and is
allowed to achive this temperature . Once this temperature is achieved ,as shown by the
reference thermocouple , the test body to be tested is then transferred to the hot water bath at
particular temperature (about 65 degree c), which was kept constant using thermostat
provided. The cylinder is allowed to equilibrate to this temperature .digital temperature
indicator and stopwatch is used to record the temperature read by thermocouple every 5
seconds.
I. Fill the heating tank with fluid upto 75% level so that test specimen can be
dipped into the fluid.
II. Switch on the heater and maintain the desired temperature of the water /oil
using the regulator provided on the tank .
III. Note down this temperature (Ta) and intial temperature of the body as
indicated by the DTI.
IV. Now dip the selected body into this hot fluid with the help of stand provided.
V. With selector switch of DTI at proper thermocouple number and start noting
down the unsteady state temperature response (T) for a regular time interval
(about 5 or 10 secs interval).
Stirrer Reference
Thermocouple
Hot Water Bath:
Constantly stirred. Kept at
65 C
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
73
VI. After the temperature reaches the steady state take the body out of the heating
tank and note down the unsteady state temperature response of the body while
cooling .Or dip the body into the cold water bath and note down the unsteady
state temperature response (T) for a regular time interval for cooling.
Repeat the above procedure with second body.
5. OBSERVATION TABLE:
Body Shape : Copper Cylinder
Diameter : 50 MM
Length :150 mm
Volume : 2.9437 * 10-4
MM2
Surface Area : 0.0235 M
Thermal Conductivity : 206 w/m.k
Density :
Specific Heat :
Cycle : Heating / Cooling
Surrounding Temperature (Ta) : C
Initial body Temperature (Ti) : C
Sr.
No.
Time
(sec)
Temperature
Response
(C)
(T - Ta/
Ti – Ta)
Unit Surface
Conductance
(w/ m2*
oC)
Biot
Number
Fourier
Number
(t) T = T3 h Bi Fo
GRAPHS: Plot [(T-Ta)/ (Ti-Ta)] vs. t for heating as well as cooling cycle.
OBSERVATION TABLE:
Body Shape : MS Sphere
Diameter : 50 MM
Volume :2.9437 * 10-4
MM2
Surface Area :0.0235 M
Thermal Conductivity : 206 w/m.k
Density :8900 kg/m3
Specific Heat : 0.38 kJ/ kg oC
Cycle : Heating / Cooling
Surrounding Temperature (Ta) : C
Initial body Temperature (Ti) : C
Sr.
No.
Time
(sec)
Temperature
Response
(C)
(T - Ta/
Ti – Ta)
Unit Surface
Conductance
(w/ m2*
oC)
Biot
Number
Fourier
Number
(t) T = T3 h Bi Fo
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
74
GRAPHS: Plot [(T-Ta)/ (Ti-Ta)] vs. t for heating as well as cooling cycle.
SAMPLE CALCULATION:
Sample calculation of h using lumped-sum model
(For Aluminium D=0.05 M, L=0.150 M)
First, obtain the equation of the line.where x=(v/As),X=
Next, use the slope of that equation in the following equation:
2
pCrslopeh
SAMPLE CALCULATION OF H FROM HEISLER CHART
First, choose a point on the graph of Y vs. t. Then substitute those values into the following
equations:
21
x
tX
0TT
TTY
1xh
km
Using the Heisler chart, find the point, which corresponds to a value for m. Rearranging the
equation for m yields the following:
1xm
kh
Sample calculation of C1 value:
For 3.0-inch diameter aluminum cylinder, from Table 2 the average experimental
h is 1335.
h = 1335 Km
inW
2
D = 3.0 in.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
75
0.382D
1Ch (equation (9))
Therefore, C1 = 2031 Km
inW
2
h values for all trials
Material trials: L/D trials: Radius Trials:
D=1.5 in. L=6 in. aluminum D=2 in. aluminum L=6 in.
h(W/m^2*K) h(heisler) h(W/m^2*K) h(heisler) h(W/m^2*K) h(heisler)
steel 1 974.771 945 L=4 in 1 1801.954 1622 D=1 in 1 2086.937
steel 2 1039.984 945 L=4 in 2 1823.516 1352 D=1 in 2 2083.856
steel 3 985.068 859 L=4 in. 3 1829.677 1352 D=1 in 3 2048.432
AVERAGE 999.941 916 AVERAGE 1818.382 1442 AVERAGE 2073.075
stdev 35.05835762 49.65212315 stdev 14.55702862 155.8845727 stdev 21.39699107
copper1 2136.796 L=6 in. 1 1943.6467 1474 D=1.5 in 1 1266.024
copper2 2042.045 L=6 in. 2 1919.0046 1622 D=1.5 in 2 1520.152
copper3 1979.967 L=6 in. 3 1885.1217 1622 D=1.5 in 3 1240.691
AVERAGE 2052.936 AVERAGE 1915.924333 1573 AVERAGE 1342.289
stdev 78.97970765 stdev 29.38383805 85.44783984 stdev 154.5537942
brass1 1809.447 1365 L=7.5 in. 1 2008.3322 1622 D=2 in 1 1697.273
brass2 1753.195 1365 L=7.5 in. 2 1959.048 1707 D=2 in 2 1152.051
brass3 1906.326 1560 L=7.5 in. 3 1949.8072 1622 D=2 in 3 1497.05
AVERAGE 1822.989333 1430 AVERAGE 1972.3958 1650 AVERAGE 1448.791333
stdev 77.45851718 112.5833025 stdev 31.46294217 49.07477288 stdev 275.7959962
aluminum1 1266.024 L=9 in. 1 1774.232 1622 D=2.5 in 1 1478.568 1298
aluminum2 1520.152 L=9 in. 2 1811.1953 1622 D=2.5 in 2 1259.093 1442
aluminum3 1240.691 L=9 in. 3 1801.9545 1622 D=2.5 in 3 1517.072 1442
AVERAGE 1342.289 AVERAGE 1795.793933 1622 AVERAGE 1418.244333 1394
stdev 154.5537942 stdev 19.23631521 0 stdev 139.1671645 83.13843876
D=3 in 1 1270.644 1298
D=3 in 2 1270.644 1298
D=3 in 3 1464.706 1442
AVERAGE 1335.331333 1346
stdev 112.0417479 83.13843876
6. Results
7. Discussion
8. Conclusion
9. PRECAUTIONS
1. Wait till steady state is achieved.
2. Use stabilized power supply.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
76
EXPERIMENT NO. 8 (a)
HEAT TRANSFER IN AGITATED VESSEL (JACKET & COIL)
1. Aim & Objective To study heat transfer phenomena in agitated vessel with jacket & helical coil system and
comparison experimental overall heat transfer coefficients in both jacket & coil.
2. Apparatus
2 nos. pump driven setup consisting of agitated vessel with helical coil, 2 sump tanks, PID
temperature controller, temperature indicators, rotameters.
3. Theory
Whenever the fluid motion is varied by external means the heat is transferred by forced
convection. Most of the time fluid is agitated by circulating the hot and cold fluids at rapid
rates on the opposite sides of pipes or tubes. The rate of heat transfer by forced convection to
an incompressible fluid traveling in turbulent flow in a pipe of uniform diameter at constant
mass rate has been found to be influenced by the velocity, density, specific heat, thermal
conductivity, viscosity of fluid as well as the inside diameter of the pipe.
The velocity, viscosity, density and diameter affect the thickness of fluid film at the pipe wall
through which the heat must first be conducted and they also influence the extent of fluid
mixing. The thermal conductivity of the fluid and the specific heat reflects the variation of the
average fluid temperature as a result of unit heat absorption. A simple jacketed pan or kettle
is very commonly used in the chemical industries as a reaction vessel. In many cases, such as
in nitration or sulphonation reactions, heat has to be removed or added to the mixture in order
either to control the rate of reaction or to bring it to completion.
The addition or removal of heat is conveniently arranged by passing steam or water through a
jacket fitted to the outside of the vessel or through a helical coil fitted to the inside. In either
case some form of agitator is used to obtain even distribution in the vessel. This may be of
the anchor type for very thick mixes or a propeller or turbine if the contents are too viscous.
4. Experimental Setup:
Agitated vessel consist impeller mounted on the shaft, which is driven by a motor. The
formation of swirling water in an agitated vessel can be prevented by introduction of baffles.
The schematic is shown in below figure
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
77
Fig 1: Schematic diagram of Heat Transfer in Agitated Vessel experiment
5. Experimental Procedure:
Open the drain cock of the vessel and remove all the water from inside.
Fill the agitated vessel with about 4-5 liter of water (about 70-75% height of the vessel)
for a batch operation.
Switch on the heater and heat the water to the desired degree of hotness (about 70-80 C).
Intermittently switch ON the pump with bypass line valve fully open and supply valve
fully closed to ensure thorough mixing of water in the tank to ensure uniform
temperature.
Measure the temperature of bulk water periodically with the help of the thermocouple
placed in the thermowell.
Now start the hot water supply in the coil or jacket depending upon the experiment. And
measure its inlet and outlet temperatures periodically with the thermocouples placed in
the thermowells.
Note down the values of cooling water inlet and outlet temperatures and cooling water
flow rate, hot water inlet and outlet temperatures and hot water flow rate.
6. Observations & Calculations
Thermal conductivity of SS (K) = 16.86 W/ m.K
Diameter of agitated vessel (Da) = 0.73 m
Height of agitated vessel (h) = 0.265 m
Diameter of coil (Dc) = 0.11m
Length of coil (Lc) = 5.115 m
6.1 Properties of water at 331 K (58 0C)
Density of water 984.1 Kg/cm3
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
78
Specific heat of water 4187 J/Kg.K
Viscosity of water 485 * 10-6
Pa.sec
6.2 Observation table
For hot water in coil:
S.No Hot water
flow rate
(litres/min)
Cold water
flow rate
(litres/min)
T1
(° C)
T2
(° C)
T3
(° C)
T4
(° C)
For hot water in jacket:
S.No Hot water
flow rate
(litres/min)
Cold water
flow rate
(litres/min)
T1
(° C)
T2
(° C)
T5
(° C)
T6
(° C)
6.3 Calculations:
6.3.1 Experimental Value calculations:
For hot water in coil:
Heat Gained by the Cooling Water (Q) = mw Cp (T4– T3)/60
= .................J/ sec
= Uexpt Acoil [ T2 - ( T3 + T4 ) / 2 ]
For hot water in jacket:
Heat Gained by the Cooling Water (Q) = mw Cp (T6 – T5)/60
= .................. J/ sec
= Uexpt Ajacket [ T2 - ( T5 + T6) / 2 ]
Calculate the value of Uexpt from the above equations for both jacket and coil.
Where,
QC = Cold water flow rate, LPM.
QH = Hot water flow rate, LPM.
T1 = Bulk water inlet temperature of vessel.
T2 = Bulk water outlet temperature of vessel.
T3 = Coil inlet temperature, oC.
T4 = Coil outlet temperature, oC.
T5 = Jacket inlet temperature, oC.
T6 = Jacket outlet temperature, oC.
Ajacket = 0.11 m2
7. Results & Conclusions
Experimental heat transfer coefficients for hot water flow through coil are _______ W/m2 °C
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
79
Experimental heat transfer coefficients for hot water flow through jacket are _______ W/m2
°C
8. PRECAUTIONS:
Make sure during the test period Hot Water Tank should not be emptied totally and the heater
must not be exposed to air if the Heater is ON, otherwise it will be damaged.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
80
EXPERIMENT NO. 8 (b)
FLUIDIZED BED HEAT TRANSFER UNIT
1. AIM
To study the performance of the heat transfer in Fluidized bed
To study the heat transfer coefficient for heat transfer in fluidized bed.
2. Apparatus:
2 nos. pump driven setup consisting of fluidized bed, 2 sump tanks, PID temperature
controller, temperature indicators, rotameters.
3. THEORY:
When a liquid or a gas is passed at very low velocity up through a bed of solid particles, the
particles do not move ,and the pressure drop is given by the Ergun equation. If the fluid
velocity is steadily increased ,the pressure drop and the drag on individual particles
increase,and eventually the particles start to move and become suspended in the fluid. The
terms “fluidization” and “fluidized bed” are used to describe the condition of fully suspended
particles,since the suspension behaves like a dense fluid.
Fluidized beds are used extensively in the chemical process industries, particularly for the
cracking of high-molecular-weight petroleum fractions.Such beds inherently possess
excellent heat transfer and mixing characteristics.These are devices in which a large surface
area of contact between a liquid and a gas ,or a solid and a gas or liquid is obtained for
achieving rapid mass and heat transfer and for chemical reactions.
The fluidized bed is one of the best known contacting methods used in the processing
industry, for instance in oil refinery plants. Among its chief advantages are that the particles
are well mixed leading to low temperature gradients, they are suitable for both small and
large scale operations and they allow continuous processing. There are many well established
operations that utilize this technology, including cracking and reforming of hydrocarbons,
coal carbonization and gasification, ore roasting, Fisher-Tropsch synthesis, coking, aluminum
production, melamine production, and coating preparations. Nowadays, you will find
fluidized beds used in catalyst regeneration, solid-gas reactors, combustion of coal, roasting
of ores, drying, and gas adsorption operations The application of fluidization is also well
recognized in nuclear engineering as a unit operation for example, in uranium extraction,
nuclear fuel fabrication, reprocessing of fuel and waste disposal.
4. EXPERIMENTAL PROCEDURE:
Fill the water in cold water supply tank with about 100 litre of clean tap water. After
filling tank upto 50% start water pump and fill the overhead heater tank by
controlling bypass and supply valve.
As the heater tank fills with water to a level of heater, Switch on the immersion type
heater provided in the hot water tank and heat the water to the desired temperature
(about 60-70 C). Intermittently switch ON the pump with bypass line valve fully
open and supply valve fully closed to ensure thorough mixing of water in the tank to
ensure uniform temperature.
After achieving the desired temperature of water in the hot water tank, allow the hot
water to flow through inner pipe side and adjust the flow rate to the desired value
using the valve of rotameter. Drain the exit of the hot water to the drainage.
Start the cold water supply on the outer pipe side and adjust the flow rate to the
desired value-using valve of rotameter. Now place the outlet of outer tube side in to
the drain line.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
81
Observe the inlet and outlet temperature of both cold and hot water streams and note
down them after they achieve steady state.
Also note down the Flow rates of hot water and cold water with the help of
Rotameters.
Repeat the above procedure either by changing the Flow rates or by changing the
inlet temperature of the hot water.
5. OBSERVATION TABLE AND CALCULATION :
Density of water = 1 kg/l
Diameter of bed do = 2 inch
Length of bed L = 12 inch
Specific heat of water = CpH = CpC = 4187 J/Kg.K
Hot Water Inner Tube Side Cold Water Outer Tube Side
Flow Rate
mh
LPM
Inlet
Temp.
T1
(C)
Outlet
Temp.
T2
(C)
Flow Rate
mc
LPM
Inlet
Temp.
T3
(C)
Outlet
Temp.
T4
(C)
Flow rate of hot water in kg/ s mH = mh * / 60
=____________ kg/ s
Heat Transferred by the Hot Water to the Cold Water
QH = mH * CpH * (T1 – T2)
=____________ W
Flow rate of cold water in kg/ s mC = mc * / 60
= ___________ kg/ s
Heat Gained by the Cold Water from the Hot Water
QC = mC * CpC * (T4 – T3)
= ____________ W
Average Heat Q = (QH + QC) / 2
= ____________ W
Area for the Heat Transfer, A = * do * L
= ____________ m2
For Parallel flow
( T1 – T3 ) - ( T2 – T4 )
LMTD = --------------------------------
ln ( ( T1 – T3 ) / ( T2 – T4 ) )
= _____________ 0C
Overall Heat transfer coefficient can be calculated using,
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
82
U = Q / (A * LMTD)
= ____________ W/ m2 C
6. RESULT AND DISCUSSIONS:
FOR PARALLEL FLOW
OVERALL HEAT TRANSFER COEFFICIENT = ---------------- W/ m2.C
7. PRECAUTIONS:
Make sure during the test period Hot Water Tank should not be emptied totally and the
heater must not be exposed to air if the Heater is ON, otherwise it will be damaged.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
83
EXPERIMENT NO. 9 (a)
PARALLEL FLOW AND COUNTER FLOW HEAT EXCHANGER
1. Aim
a) To calculate the overall Heat transfer coefficient of the heat exchanger.
b) To calculate the local heat transfer coefficient of the heat exchanger using Seider
Tate Equation and Dittus-Boelter Equation.
2. Objective
To study the heat transfer phenomena in parallel and counter flow arrangements.
3. Theory
The double-pipe heat exchanger is one of the simplest types of heat exchangers. It is called a
double-pipe exchanger because one fluid flows inside a pipe and the other fluid flows
between that pipe and another pipe that surrounds the first. This is a concentric tube
construction. Flow in a double-pipe heat exchanger can be co-current or counter-current.
There are two flow configurations: co-current is when the flow of the two streams is in the
same direction, counter current is when the flow of the streams is in opposite directions.
As conditions in the pipes change: inlet temperatures, flow rates, fluid properties, fluid
composition, etc., the amount of heat transferred also changes. This transient behaviour
leads to change in process temperatures, which will lead to a point where the temperature
distribution becomes steady. When heat is beginning to be transferred, this changes the
temperature of the fluids. Until these temperatures reach a steady state their behaviour is
dependent on time.
In this double-pipe heat exchanger a hot process fluid flowing through the inner pipe transfers
its heat to cooling water flowing in the outer pipe. The system is in steady state until
conditions change, such as flow rate or inlet temperature. These changes in conditions cause
the temperature distribution to change with time until a new steady state is reached. The new
steady state will be observed once the inlet and outlet temperatures for the process and
coolant fluid become stable. In reality, the temperatures will never be completely stable, but
with large enough changes in inlet temperatures or flow rates a relative steady state can be
experimentally observed.
As with any process the analysis of a heat exchanger begins with an energy and material
balance. Before doing a complete energy balance a few assumptions can be made. The first
assumption is that the energy lost to the surroundings from the cooling water or from the U-
bends in the inner pipe to the surroundings is negligible. We also assume negligible potential
or kinetic energy changes and constant physical properties such as specific heats and density.
These assumptions also simplify the basic heat-exchanger equations.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
84
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
85
4. Calculation
Assumption
Steady state conditions exist.
Fluid properties remain constant and are evaluated at a temperature of fluid.
Nomenclature
T refers to the temperature of the warmer fluid.
t refers to the temperature of the cooler fluid.
w subscript refers to the warmer fluid.
h subscript refers to hydraulic diameter
c subscript refers to the cooler fluid.
a subscript refers to the annular flow area or dimension.
p subscript refers to the tubular flow area or dimension.
1 subscript refers to an inlet condition.
2 subscript refers to an outlet condition.
e subscript refers to equivalent diameter.
Fluid Properties
Counter current:
S.no
Flow rate
mh
(Kg/m)
Flow rate
mc
(Kg/m)
Hot water in
(ºC)
Hot water out
(ºC)
Cold water in
(ºC)
Cold water out
(ºC)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
86
Co-current:
Tubing Sizes
IDa =
IDp = ODp =
Flow Area
Area of pipe A= π*D*L =
Area of annulus A = π*De*L =
Fluid Velocity
5. Results
The Over All heat transfer coefficient =
The local heat transfer coefficient =
E
EXPERIMENT NO. 9 (b)
SHELL AND TUBE HEAT EXCHANGER
1. Aim
Study of Shell and Tube Heat Exchanger
2. Objective
To calculate overall heat transfer coefficient for shell & tube heat exchanger.
S.no
Flow rate
mh
(Kg/m)
Flow rate
mc
(Kg/m)
Hot water in
(ºC)
Hot water out
(ºC)
Cold water in
(ºC)
Cold water out
(ºC)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
87
3. Theory Heat Exchanger is device in which heat is transferred from one fluid to another. The
necessity for doing this arises in a multitude of industrial applications. Common examples of
heat exchangers are the radiator of a car, the condenser at the back of a domestic refrigerator
and the steam boiler of a thermal power plant.
Heat Exchangers are classified in three categories:
1) Transfer Type.
2) Storage Type.
3) Direct Contact Type.
A transfer type of heat exchanger is one on which both fluids pass simultaneously through the
device and heat is transferred through separating walls. In practice, most of the heat
exchangers used are transfer type ones.
Shell and tube heat exchangers are the most widely used in chemical process industries. A
shell and tube exchanger consists of a bundle of tubes enclosed in a cylindrical shell. The
ends of the tubes are fitted into tube sheets, which separate the shell-side and tube-side fluids.
Baffles are provided in the shell to direct the fluid flow and support the tubes. The tubes are
arranged in triangular or square pitch. One fluid flows inside the tube and is called the tube
side fluid, the other fluid flows outside the tubes and is called the shell side fluid.
The shell and tube heat exchangers are further classified according to flow arrangement as -
1. Single Pass
2. Multiple Pass
The simplest shell and tube heat exchanger is 1-1 heat exchanger (one shell pass and one tube
pass), the other types are 1-2 heat exchangers and 2-4 heat exchanger.
The transfer of heat from the hot fluid to the wall or tube surface is accompanied by
convection through the tube wall or plate by conduction, and then by convection to the cold
fluid. The flow arrangement in a shell and tube heat exchanger could either be co-current or
countercurrent. The heat transfer coefficients outside the tube bundles are referred as shell
side coefficients. Baffles also increase the convection coefficient of the shell side fluid by
inducing turbulence and a cross flow velocity component.
Any heat exchanger design requires rigorous analysis. One of the most essential parts of the
heat exchanger analysis is determination of the overall heat transfer coefficient. The overall
heat transfer coefficient is defined in terms of the total thermal resistance to heat transfer
between two fluids.
The heat lost by the hot fluid can be calculated
hq = Heat Transfer rate to the hot water.
KCal/hr TTCmq hohiPhhh
Heat taken by the cold fluid can also be calculated
cq = Heat Transfer rate to the cold water.
KCal/hr TTCmq cicoPccc
2
qqQ hc
avg
mo
avg
oTA
QU
4. Experimental setup
4.1. DESCRIPTION
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
88
The apparatus consists of 1-2 Pass Shell and Tube heat exchanger. The hot fluid is hot
water, which is attained from an insulating water bath using a magnetic drive pump and it
flow through the inner tube while the cold water flowing through the annuals. For flow
measurement rotameters are provided at inlet of cold water and outlet of hot water line.
The hot water bath is of recycled type with Digital Temperature Controller 0 to 100 oC.
4.2. REQUIREMENTS
Water supply 20 lit/min (approx.), Drain, Electricity Supply: 1 Phase, 220 V AC, and 4 kW,
Floor area of 1.5 m x 0.75 m
4.3. SPECIFICATIONS
1. Shell
Material = S.S.
Dia. = 220 mm
Length = 500 mm
25% cut baffles at 100 mm distance 4 Nos.
2. Tube
Material = S.S
OD = 16 mm
ID = 13 mm
Length of tubes = 500 mm
Nos. of tubes = 24
3. Temperature Controller = Digital 0 – 199.9oC
4. Temperature Sensors = RTD PT-100 type (5 nos.)
5. Temperature Indicator = Digital 0 to 200oC with multi-channel switch.
6. Electric Heater = 230 V AC 2 kW (2 Nos.)
7. Flow measurement = Rotameter (2 No.)
8. Water Bath = Material: SS insulated with ceramic wool and powder
coated MS outer Shell fitted with heating elements.
9. Pump = FHP magnetic drive pump (max. operating temp
85oC).
5. Experimental procedure:
Starting Procedure:
1. Clean the apparatus and make Water Bath free from Dust.
2. Close all the drain valves provided.
3. Fill Water Bath ¾ with Clean Water and ensure that no foreign particles are there.
4. Connect Cold water supply to the inlet of Cold water Rotameter Line.
5. Connect Outlet of Cold water from Shell to Drain.
6. Ensure that all On/Off Switches given on the Panel are at OFF position.
7. Now switch on the Main Power Supply (220 V AC, 50 Hz).
8. Switch on Heater by operating Rotary Switch given on the Panel.
9. Set Temperature of the Water Bath with the help of Digital Temperature Controller.
10. Open Flow Control Valve and By-Pass Valve for Hot Water Supply.
11. Switch on Magnetic Pump for Hot Water supply.
12. Adjust Hot water flow rate with the help of Flow Control Valve and Rotameter.
13. Record the temperatures of Hot and Cold water Inlet & Outlet when steady state is
achieved.
Closing Procedure:
1. When experiment is over, Switch off heater first.
2. Switch of Magnetic Pump for Hot Water supply.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
89
3. Switch off Power Supply to Panel.
4. Stop cold water supply with the help of Flow Control Valve.
5. Stop Hot water supply with the help of Flow Control Valve.
6. Drain Cold and Hot water from the shell with the help of given drain valves.
7. Drain Water Bath with the help of Drain valve.
6. Observation & calculation:
DATA:
Inside heat transfer area, Ai = 3.187 x 10-3 m2
Outside heat transfer area, Ao = 4.827 x 10-3 m2
OBSERVATION TABLE:
S.
No.
Hot water side Cold water side
Flow rate mh Kg/hr Thi oC Tho
oC Flow rate mc kg/hr Tci
oC Tco
oC
1
2
3
4
CALCULATIONS:
1. Rate of heat transfer from hot water,
hohiphhh TTCMQ , Watt
2. Rate of heat transfer to cold water,
cicopccc TTCMQ , Watt
3. Average heat transfer,
2
QQQ ch , Watt
4. LMTD,
1
2
12m
T
Tln
TTT
Where: T1 = Thi - TCi (for parallel flow)
= Thi - TCo (for counter flow)
and T2 = Tho - TCo (for parallel flow)
= Tho- TCi (for counter flow)
Note that in a special case of Counter Flow Exchanger exists when the heat capacity rates
Cc & Ch are equal, then Th i - Tc o = T h o - T c i thereby making Ti = To . In this case
LMTD is of the form 0/0 and so undefined. But it is obvious that since T is constant
throughout the exchanger, hence
Tm = Ti = To
(acc. to ref. Fundamental of Engineering Heat & Mass Transfer by R.C. Sachdeva, Pg. 499)
5. Overall heat transfer coefficient,
mi
iTFA
QU
, W/m
2-OC
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
90
mO
OTFA
QU
, W/m
2-OC
Heat Transfer rate, is calculated as
Qh = -------- W
Qc = -------- W
Q = 2
ch QQ W
(Assume Cph = Cpc = 4.176 J /kg- ºC)
LMTD - logarithmic mean temperature difference that can be calculated as per the following
formula:
LMTD = Tm = oi
oi
TTln
TT
Where Ti = T h i - T c i (for parallel flow)
= T h i - Tc o (for counter flow)
and To = T ho -T c o (for parallel flow)
= T ho - T c i (for counter flow)
Note that in a special case of Counter Flow Exchanger exists when the heat capacity rates Cc
& Ch are equal, then Th i - Tc o = T h o - T c i thereby making Ti = To. In this case, LMTD is
of the form 0/0 and so undefined. But it is obvious that since T is constant throughout the
exchanger, hence
Tm = Ti = To
Overall heat transfer coefficient can be calculated by using.
Q = U ATm
Ui = Q/(Ai Tm) W/m² ºC
Uo = Q/(Ao Tm) W/m² ºC
NOMENCLATURE:
Mc = Cold water flow rate, Kg/s
Mh = Hot water flow rate, Kg/s
Tci = Cold water inlet temp.
Thi = Hot water inlet temp.
Tco = Cold water outlet temp.
Tho = Hot water outlet temp.
Tc = Mean temp. of cold water
Th = Mean temp. of hot water ,
c = Density of Cold fluid, kg/m3
Cpc = Specific heat of cold fluid, J/kg-C
pc = Thermal Conductivity of cold fluid, W/mC
h = Density of Hot fluid, kg/m3
Cph = Specific heat of Hot fluid, J/kg oC
Ph = Thermal Conductivity of Hot fluid, W/mC
Qh = Heat lost by hot water, W
Qc = Heat gained by cold water, W
Q = Average heat transfer, W
LMTD = Logarithm mean temp. difference
A = Area of Heat Transfer, m2
Do = Outer dia of S.S tube, m
L = length of the tube, m
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
91
U = Overall heat transfer coefficient, W / m2 o
C
7. Results & discussion
8. Conclusion
9. Precautions & maintenance instructions
References:
1. Holman, J.P., “Heat Transfer”, 8th
ed.,McGraw Hill, NY, 1976.
2. Kern, D.Q., “Process Heat Transfer”, 1st ed.,McGraw Hill, NY, 1965.
3. McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical Engineering”,
4th
ed.McGraw Hill, NY, 1985.
4. Coulson, J.M., Richardson, J.F., “Coulson & Richardson’s Chemical Engineering Vol.
- 1”, 5th
ed.Asian Books ltd., ND, 1996.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
92
EXPERIMENT NO. 10 (a)
PLATE TYPE HEAT EXCHANGE
1. Aim:
To analyze the performance of an existing plate type Heat Exchanger.
2. Objectives:
1. To calculate Overall Heat Transfer Coefficient & effectiveness for plate type Heat
Exchanger.
2. To analyze effects of changing the flow rate for hot water & cold water fluids.
3. Theory:
A heat exchanger is a device that facilitates the transfer of heat between two fluids at
different temperatures. The main mechanisms for heat transfer in heat exchangers are
conduction and convection. There are many types of heat exchangers. An example of one is a
plate and frame heat exchanger. A plate and frame heat exchanger is a device that utilizes
corrugated pressed plates for heat by counter-current flow.
Other types of heat exchangers include the miniature, brazed heat exchanger, traditional
gasket plate heat exchangers, welded heat exchangers, plate and shell heat exchanger, and the
spiral heat exchanger.
Plate and frame heat exchangers, are used in many different processes at a broad range of
temperatures and with a wide variety of substances. Plate and frame heat exchangers have
been used in industry since 1930. During recent years, research into Plate and frame heat
exchangers has increased considerably and there is now a state-of-the-art compilation of
knowledge on this topic.
During liquid-liquid heat exchange, it is important to maintain relatively low temperatures
and pressures. The heat exchange process should not exceed temperatures and pressures of
250 degrees Celsius and 25 atmospheres respectively. Plate and frame heat exchangers are
not exclusive for liquid-liquid heat exchange, but also have some usage in liquid-gas and
liquid-condensing-vapor combination heat exchange.
Plate and frame heat exchangers are devices that are made up of many plates stacked together
on a frame, and either bolted or welded together. Each plate, consists of tiny little
passageways, through which, the fluids are passed. The cold and hot fluids travel through two
different passage ways in a counter current flow, which maximizes the heat transfer by
creating a temperature gradient that is constantly from the hot fluid to the cold fluid, as
illustrated below.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
93
FIG 1: Single-pass countercurrent flow.
In Fig 1, it can be seen how two fluids move within the plates. The black arrows, for
example, represent the hot fluid and the gray arrows represent the cold fluid. As can be seen
in the above diagram, the fluids move in opposing directions as they cross the plates.
FIG 2: Parts of a typical plate and frame heat exchanger
FIG 2 above shows the different parts of a Plate and frame heat exchangers. The fixed head is
where the two fluids enter. One fluid enters through the bottom, and the other fluid enters
through the top. The movable follower is the back of Plate and frame heat exchangers. It can
be adjusted back and forth for the addition or removal of plates in the plate pack. The guiding
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
94
and carrying bar provide support for the plate pack and the follower runs along these bars.
The clamping bolts secure the stacked structure.
FIG 3(a) Intermitting FIG 3(b) Chevron
Fig 3 above shows the two main types of plates. The first employs the intermitting
corrugations. These corrugations are at right angles with the fluid flows. The fluid goes down
the plate and hits the corrugation line, runs to the other end of the plate, and goes down
through the slit at the end of the line, after which, the fluid hits another corrugation plate and
continues this pattern throughout the plate. The maximum gap size between the corrugations
is 3 to 5 mm maximum. With this style of plate, turbulence in the flow is increased by
constantly hitting the plate. The size of the corrugation gaps is directly proportional to the
amount of turbulent increase in the fluid.
The chevron corrugations are slanted downward at an angle of beta. The fluid flows steadily
down the plate crisscrossing back forth. The plate in FIG 3(b) has the troughs going in the
opposite direction for the other fluids. This maximizes the crossing points of the two fluids,
thus, increasing the heat transfer. If the angle is about 80 degrees, the heat transfer increases
due to the swirling flow of the two fluids in opposite directions in opposing plates.
FIG 4: Flow patern of fluids in plate type heat exchanger
3.1. Advantages:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
95
Flexibility in the efficiency: The number of plates can be adjusted for more or less
heat transfer
Compactness: The numerous amounts of little corrugations increase the surface area
for heat transfer in a small volume.
Low Cost: The plates are inexpensive and easy to produce
Less Corrosion: the plates are typically made of stainless steel
Low Maintenance: very easy to clean
Temperature Control: can maintain a relatively low temperature difference in fluid
because of the small diameters inside the corrugations.
High thermal efficiency
Reduced Liquid Volume: due to narrow flow channels
Due to their efficiency, they can be selected to use less coolant
3.2. Disadvantages:
Temperature and Pressure Limitations: Temperature cannot go above 250 degrees
Celsius and pressure cannot go exceed 25 atmospheres.
Leakage: Corrosive materials can cause leakage
Pressure Increase: The small diameter of the corrugations can cause a heavy
increase in the pressure, so pumping costs must to taken into account.
3.3. Applications: Some Plate Heat Exchangers are designed specifically for use in the food, dairy and brewing
industries. A major feature of Plate and frame heat exchangers used for this process is a
sanitary plate designed to achieve optimum distribution of the product over the entire plate
surface. These liquid food plants are designed for the concentration of malt, beer, yeast, fruit
juices, pulp and other liquid food products to remove water and stabilize enzymes, prior to
product storage.
The Plate and Frame Heat Exchanger, can also be used in the cooling and heating of fibrous
materials, such as, fruit juices and fluids containing pulp, fruit purees, turbid fruit juices,
dairy mixes, citrus pulp, and highly viscous liquids.
The unique capabilities of the PHE makes it suitable for a wide range of applications that
extend beyond refrigeration such as: refrigerant evaporating & condensing, heat pumps,
steam heating, engine or hydraulic oil cooling, swimming pool heating, and heat recovery for
industrial applications e.g. waste water, dye works, paper manufacture etc.
When choosing a heat exchanger, the design engineer has to take into account many factors.
Some of these factors include, fluid characteristics, operating pressure, operating temperature
and the range of possible flow rates.
4. Experimental Setup:
The miniature exchanger supplied for the Lab project consists of a pack of 11 plates, 9 of
which have water on both sides that contributes to heat transfer. The plates have sealing
gaskets and are held together in a frame between a fixed end plate and moving end plate. Two
nuts/bolts passing through the end plates compress the plates and gaskets together. Hot and
cold fluids flow between channels on alternate sides of the plates to promote heat transfer.
The plate heat exchanger with 11 plates is configured for 5 passes in series. Although the
overall flow arrangement may be either countercurrent or Co-current, the flow arrangements
on either side of each individual plate alternates between countercurrent and Co-current
patterns.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
96
Each end plate of the heat exchanger incorporates tapings for the hot and cold fluids to
enter/leave the exchanger, and thermocouples in each of the tapings allow the temperatures of
the fluids to be measured. The four type K thermocouple temperature sensors are labeled T1
to T4 for identification and each lead is terminated with a miniature thermocouple plug for
connection to the appropriate socket on the service unit. Flexible tubing attached to each fluid
inlet/outlet is terminated with a ferrule to allow rapid connection to the appropriate quick
release fittings on the HT30X service unit.
In normal countercurrent operation the flexible connections are hot water inlet adjacent to
temperature sensor T1, hot water outlet adjacent to temperature sensor T2, cold-water inlet
adjacent to temperature sensor T3, and cold-water outlet adjacent to temperature sensor T4.
The pattern of holes in the plates and the shape of the gaskets determine the direction of low
through the exchanger. The pates are made of SS-316 and incorporate a locating groove for
the gasket. Each plate has a pressed chevron pattern to promote turbulence and provide
multiple support points. As a result of the turbulence promoters, which cause flow separation
around protuberances, turbulent-like behavior can begin at Reynolds numbers as low as
several hundred, thereby enhancing heat transfer performance.
Silicone rubber gasket on each plate ensures that the adjacent flow channels are sealed from
each other.
5. Experimental Procedure:
1. Fill the thermic fluid tank with about 75 liter of thermic fluid (say water - here).
2. Switch on the immersion type heater (6 kW) provided in the thermic fluid tank and heat
the thermic fluid to the desired temperature (about 50-60 C). Intermittently switch ON
the pump with bypass line valve fully open and supply valve fully closed to ensure
through mixing of thermic fluid in the tank to ensure uniform temperature.
3. After achieving the desired temperature of thermic fluid in the thermic fluid tank, switch
ON the pump (0.5 HP) and allow the hot thermic fluid to flow through plates and adjust
the flow rate to the desired value using the valve for about five minutes. Recycle the exit
of the hot thermic fluid to the thermic fluid tank.
4. Start the cold water supply into plates and adjust the flow rate to the desired value.
5. Monitor the hot thermic fluid inlet temperature and maintain it at the constant value by
switching the heater either on/ off with the help of thermostat provided on the control
panel of the tank.
6. Observe the inlet and outlet temperature of both cold water and hot thermic fluid streams
and note down them after they achieve steady state.
7. Also note down the flow rates of hot thermic fluid and cold water with the help of
Rotameters.
8. Repeat the above procedure either by changing the flow rates or by changing the inlet
temperature of the hot thermic fluid.
6. Observations:
S. No.
Hot Water
Cold Water
Flow rate
mh
(LPM)
Inlet
Temp
T1
(C)
Outlet
Temp
T2
(C)
Flow rate
mc
(LPM)
Inlet
Temp.
T3
(C)
Outlet
Temp.
T4
(C)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
97
7. Calculations: The actual area of heat transfer is computed using the following equation:
A = N*a = N * L * W
Where,
N= number of plates
a= projected area of a single plate
L= the length component of the projected area of the plate
W= the width component of the projected area of the plate
Flow rate of hot water in kg/ s
mH = mh * / 60
= __________ kg/ s
Heat Transferred by the Hot Water to the Cold Water
QH = mH * CpH * (T1 – T2)
= ___________ W
Flow rate of cold water in kg/ s
mC = mc * / 60
= __________ kg/ s
Heat Gained by the Cold Water from the Hot Water
QC = mC * CpC * (T4 – T3)
= ___________ W
True Temperature Difference
442
31
4231
42
31ln
)42(31
TT
TT
TTTTT
= ______________0C
Now, average heat transfer
Q = (QH + QC )/ 2
= ______________ W
Designed Overall Heat Transfer Co-efficient
Uc = TmA
Q
*
= __________ W/m2 0C
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
98
E= EFFECTIVENESS OF THE EXCHANGER.
=MCp)cold/(MCp)min * ∆ Tcold / ∆ Thot
= ∆ Tcold / ∆ Thot
where,
∆ Tcold= the change in temperature of the cold fluid
∆ Thot= the change in temperature of the hot fluid
7.1. Model Calculations:
S. No.
Hot Water
Cold Water
Flow rate
mh
(LPM)
Inlet
Temp
T1
(C)
Outlet
Temp
T2
(C)
Flow rate
mc
(LPM)
Inlet
Temp.
T3
(C)
Outlet
Temp.
T4
(C)
1 2 41 32 3 32 36
2 4 42 36 6 34 37
3 6 47 40 6 35 42
4 8 48 44 4 38 46
5 4 48 43 8 42 44
The actual area of heat transfer is computed using the following equation:
A = N*a = N * L * W
Where,
N= number of plates =8
L= the length component of the projected area of the plate = 550 mm
W= the width component of the projected area of the plate = 125 mm
A = N*a = N * L * W
= 8 * 0.550 * 0.125
= 0.55 m2
Sample calculations for reading no -2:
Flow rate of hot water in kg/ s
mH = mh * / 60
= 4 * 1000/(1000*60)
= 0.066 kg/sec
Heat Transferred by the Hot Water to the Cold Water
QH = mH * CpH * (T1 – T2)
= 0.066 * 4.187 * (42 – 36)
= 1.6580 W(J/SEC)
Flow rate of cold water in kg/ s
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
99
mC = mc * / 60
= 6 * 1000/(1000*60)
= 0.1 kg/sec
Heat Gained by the Cold Water from the Hot Water
QC = mC * CpC * (T4 – T3)
= 0.1 * 4.187 * (37 – 34)
= 1.2561 W(J/SEC)
True Temperature Difference
32
41ln
)32(41
TT
TT
TTTTTlm
=3/(ln 2.5)
= 3.27 0C
Now, average heat transfer
Q = (QH + QC )/ 2
= 2.9141 W
Designed Overall Heat Transfer Co-efficient
TmA
Q
*
= 2.9141/(0.55 * 3.27)
= 1.6202 W/m2 0C
Effectiveness of heat exchanger:
=MCp)cold/(MCp)min * ∆ Tcold / ∆ Thot
= ∆ Tcold / ∆ Thot
= (37–34 )/ (42 – 36)
= 3/6 * 100
=50 %
where,
∆ Tcold= the change in temperature of the cold fluid
∆ Thot= the change in temperature of the hot fluid
8. Results & Discussion:
Hence, the performance of the plate type Heat Exchanger has been analysed and the Overall
Heat Transfer Coefficient & effectiveness for the plate type Heat Exchanger is calculated.
1. Overall Heat Transfer Coefficient of the plate type Heat Exchanger =
2. Effectiveness of the plate type Heat Exchanger =
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
100
9. Conclusions:
10. Precautions:
1. Make sure during the test period Hot Thermic Tank should not be emptied totally and the
heater must not be exposed to air if the Heater is ON, otherwise it will be damaged.
2. Take all observations within 5 to 10 minitues before cold water temperaturrises
significantly.
11. References:
1. http://en.wikipedia.org/wiki/Plate_heat_exchanger
2. Lawry, F.J., “Plate type heat exchangers”, chem. Eng., June 29, 1959, 89-94.
3. www.tv-me.com/download.php?a=apv.pdf
EXPERIMENT NO. 10 (b)
FINNED TUBE HEAT EXCHANGER
1. Aim:
To analyze the performance of an existing finned tube Heat Exchanger.
2. Objective:
To calculate overall heat transfer coefficient, logarithmic mean temperature difference and
effectiveness of finned tube heat exchanger.
3.Theory The heat which is conducted through a body must frequently be removed by some convection
process. For example, the heat lost by conduction through a furnace wall must be dissipated
to the surroundings through convection. In heat exchanger application a finned tube
arrangement might be used to remove heat from a hot fluid.
Consider the one-dimensional fin exposed to a surrounding fluid at a temperature T. The
temperature of the base of the fin To. Equivalent diameter of annular, de = 4 x Net free flow
area / wetted or heated perimeter
Total Wetted Perimeter, Pw = (Ds + do) + 2YNF
Heat Transfer Perimeter, PHT = do + 2YNF
Net free area in the annular of a longitudinally finned exchanger is
ANF = [(/4) (Ds2 + do
2)] - (XYNF)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
101
Fig1: Crossection of pipe and finned tube
Equivalent Diameter Based on wetted perimeter (hydraulic diameter)
(de)w = 4ANF / Pw
Based on heat transfer perimeter
(de)HT = 4 ANF / PHT
Use (de)w for the calculation of Re-No, Gz-No, D/L for Annular fluid and (de)HT for the
calculation of HT coefficient on annular side and also in evaluating the Gr-No.
Total outside heat transfer surface: (At)
Ao = 2 ( do L - NF L X)
Af = 2 NF L (2Y + X)
At = Ao + Af = 2L (do + 2NFY)
For bare tube Af = At = Ao
Heat Transfer co-relations
For turbulent flow (Re>10,000, L/D>60, 0-67<Pr < 120 )
Nu = 0.023 Re0.8
Pr0.33
= (b / w )0.14
For liquids
= (Tb / Tw)0.5
For gases (heating Tb/Tw < 1 for cooling =1, Tb /Tw>1)
For laminar flow : (Re < 2100)
Nu = 1.86 (Re Pr D/L )0.33
For Gz > 100
Nu = 1.86 (Re Pr D/L )0.33
+ 0.87 [1 + 0.015 Gr0.33
]
For liquids = (b / w )0.14
For gases = (Tb / Tw)n
For temperature ratio of 0.5 - 2, n=0, =1
For transition flow:
Nu = 0.116 (Re0.67
- 125) Pr0..33
[1+ (D/L)0.67
]
Fin Performance
Fin Effectiveness (f) is defined as the actual heat transferred by the fin divided by the heat
that ideally would be transferred if the entire fin were at base temperature.
f = mY
mY)tanh(
m = (hfPf / hfaf)1/2
= (2hf / kf X)0.5
for rectangular fin
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
102
af = 2(L + X) 2L
Fin effectiveness f is defined as the ratio of heat transferred through the fin to heat
transferred through the same bare surface having no fins.
f = f (surface area of fin / cross sectional area of fin)
Efficiency of the total heat transfer surface is expressed as weighted for efficiency:
(f)wtd = f (Af /At) + Ao /At
Over all heat transfer coefficient - U,
Q = U A (LMTD)
4. Experimental Setup:
Fins increase heat transfer surface per unit length and reduce the size of heat exchanger
required for a given service. Fins are usually welded to the tube but may also be integrally
formed. Heat exchangers with fins are made up of copper. Consider a horizontal finned tube
(Longitudinal) double pipe heat exchanger (water to air). Water flow rate can be measured by
rotameter and air flow rate can be measured by using orifice provided.
5. Procedure:
a) Clean the apparatus and make water bath free from dust.
b) Close all the drain valves provided.
c) Fill water bath ¾ with clean water and ensure that no foreign particles are there.
d) Ensure that all ON/OFF switches given on the panel are at OFF position.
e) Select the parallel or counter flow of air and operate the ball valves given on the air
stream line.
f) Now switch on the main power supply (220 V AC, 50 Hz).
g) Switch on heater by operating switch given on the panel.
h) Set temperature of the water bath with the help of digital temperature controller.
i) Open flow control valve for hot water supply.
j) Switch on magnetic pump for hot water supply.
k) Adjust hot water flow rate with the help of flow control valve provided before
rotameter.
l) Record the hot water flow rate with the help of rotameter and cold air flow rate with
the help of orifice-meter provided.
m) Record the temperatures of hot and cold fluid inlet & outlet when steady state is
achieved.
n) Take readings at different flow rates of hot water and cold air.
o) For second run again fix the valve position for parallel or counter flow of air stream.
p) Repeat the steps 8 to 14 of experiment for different flow rates of fluids.
q) Repeat the steps 5 to 16 for another flow of air stream into the heat exchanger.
6. Observations:
Flow arrangement : Counter flow / Parallel flow.
System given : copper pipe with fins
Tube side fluid : Hot water.
Annular fluid : Cold air stream.
Inner Tube : Dia 9 mm, Length 1 m. Material Copper.
Longitudinal Fins : Width 12mm, Length 1m, 4 Nos. Material: Copper.
Outer tube : Dia. 42 mm. Length 1 m. Material G.I.
Water Flow Measurement : Rotameter.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
103
Air stream Flow Measurement: Orifice-meter
Hot Water Tank : made of Stainless steel, Double Wall, insulated
with ceramic wool
Hot Water Circulation : Magnetic Pump made of Polypropylene to circulate Hot
Water. Maximum working temperature is 85°C.
Heaters : 2 kW Nichrome wire heater (1 Nos.)
Digital Temperature Controller : 0–199.9°C.
(For Hot Water Tank)
Digital Temperature Indicator: 0-199.9oC, with multi-channel switch
Temperature sensors : RTD PT-100 type 5 Nos.
With Standard make On/Off switch, Mains Indicator etc.
A good quality painted rigid MS Structure is provided to support all the parts
Data:
Copper tube outside dia ,do = 12mm
Copper tube inner dia, di = 9 mm
Fin length or tube length, L = 1000 mm
Fin height, Y = 12 mm
Fin thickness, X = 2 mm
No. of fins, Nf = 04
I D of outer shell, Ds = 42 mm
I D of orificemeter = 6.25mm
Observation Table:
Sr no. Water flow rate Ww
(kg/h) Thi
oC Tho
oC Tci
oC Tco
oC
Hot water inlet, (T1) = Thi
Hot water outlet, (T2) = Tho
Cold air stream inlet, (T3) = Tci
Cold air stream outlet (parallel), (T4) = TCo
Cold air stream outlet (counter), (T5) = TCo
Cold fluid i.e. air mean temp, (Tc) = 2
TTiO CC
OC
Hot fluid i.e water mean temp, (Th) = 2
TTiO hh
OC
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
104
From data hand book:
Thermal conductivity of fin material (Copper), Kf = 386.0 W/m-oC
Properties of water at temp T = ------- oC
Density = 1000 kg/m3
Specific heat Cp = -------J/kgoC
Thermal Conductivity k = ------- W/m -oC
7. Calculations:
Total heat transfer area = At
At = 2L (do + 2NFY)
= ---------- m2
Qc = Wc Cpc ( Tco – Tci)
Qh = Wh Cph (Tho - Thi)
Qavg = ( Qh + Qc) /2
Logarithmic Mean Temp Difference (LMTD)
LMTD =
)ln(1
2
12
T
T
TT
Over all Heat Transfer Coefficient
U = AxLMTD
Q
Use NTU method to determine the effectiveness of the heat exchanger.
For shell side fluid (air)
Cs = Wc Cpc
For tube side fluid (hot water)
CT = Wh Cph
Identify the minimum either Cmin = Cs & Cmax = CT
Or Cmin = CT & Cmax = Cs
Cmin = --------
Cmax = -----------
CR = max
min
C
C
NTU = minC
UA
For counter flow:
Effectiveness, = )]CNTU(1exp[C1
)]CNTU(1exp[1
RR
R
For parallel flow:
= R
R
C1
)]CNTU(1exp[1
For each run calculate NTU & (Try to keep CR fixed)
Plot % vs NTU for counter flow and for co-counter flow.
Nomenclature:
Tho
Tci
Thi
Tco
0
L
%
NTU = UA/Cmin
CR
CR
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
105
Ds = inner diameter of shell (outer pipe), m
do = the outer diameter of inner pipe (bare tube), m
de = Equivalent dia. of annular
NF = No. of fins per tube
X = Fin thickness, m
Y = Fin height, m
L = Nominal length of heat exchanger and length of longitudinal fin (in meters)
ANF = Net free area, m2
Qf = Cross Sectional area of fin, m2
Cp = Specific heat, KJ/kg-OC
G = Mean mass velocity, kg/m2-s
h = Heat transfer coefficient, w/m2-OC
k = Thermal conductivity, w/mOC
W = Water flow rate Kg / s.
U = Over all heat transfer co-efficient; w/m2k
Q = Heat load, w
8. Result & Discussions: Hence, the performance of the finned tube Heat Exchanger has been analysed and the Overall
Heat Transfer Coefficient, logarithmic mean temperature difference, & effectiveness for the
finned tube Heat Exchanger is calculated.
1. Logarithmic mean temperature difference of the finned heat exchanger is=
2. Overall Heat Transfer Coefficient of the finned tube Heat Exchanger =
3. Effectiveness of the finned tube Heat Exchanger =
9. Conclusion:
10. Precautions:
1. Never switch on main power supply before ensuring that all the on/off switches given on
the panel are at off position.
2. Never Switch on Heaters before filling water bath ¾ with clean water. It may damage
heaters.
3. Never run the Pump at low Voltage i.e. less than 180 Volts.
4. Never fully close the Delivery and By-pass line Valves simultaneously.
5. Always keep apparatus free from dust.
6. To prevent clogging of moving parts, run Pump at least once in a fortnight.
7. Frequently Grease/Oil the rotating parts, once in three months.
Always use clean water.
References:
1. Sinnott, R.K., Coulson & Richardson’s Chemical Engineering, Vol. 6, Butterworth-
Hienemann, Oxford, 1996.
2. http://www.enggcyclopedia.com/2012/03/finned-tube-type-heat-exchangers/
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
106
EXPERIMENT NO. 11
STEFAN-BOLTZMANN APPARATUS
1. AIM
To find out the Stefan-Boltzmann constant.
2. Objective
To study radiation heat transfer of black body.
3. Theory
All substances at all temperature (above absolute Kelvin) emit thermal radiation. Thermal
radiation is an electromagnetic wave and does not require any material medium for
propagation. All bodies can emit radiation and have also the capacity to absorb all of a part
of the radiation coming from the surrounding towards it.
The most commonly used law of thermal radiation is the Stefan Boltzmann law which states
that thermal radiation heat flux or emissive power of a black surface is proportional to the
fourth power of absolute temperature of the surface and is given by,
The constant of proportionally is called the Stefan Boltzmann constant and has the value of
5.67 x 10-8
W/m² K4
. The Stefan Boltzmann law can be derived by integrating the Planck’s
law over the entire spectrum of wavelength from 0 to infinity. The objective of this
experimental set up is to measure the value of this constant fairly closely, by an easy
experimental arrangement.
4. Experimental Description
The apparatus is centered on a flanged copper hemisphere B fixed on a flat non-conducting
plate A. The outer surface of B is enclosed in a metal water jacket used to heat B to some
suitable constant temperature.
One RTD PT-100 type temperature sensor is attached to the inner wall of hemisphere B to
measure its temperature and to be read by a temperature indicator.
The disc D, which is mounted in an insulating Bakelite sleeve is fitted in a hole drilled in the
center of the base plate A. An RTD PT-100 temperature sensor is used to measure the
temperature of D i.e. TD. The Temperature Sensor is mounted on the disc to study the rise of
its temperature.
5. Utilities Required Electricity Supply: 1 Phase, 220 V AC, 2 kW.
Table for set-up support
6. Experimental Procedure
a) Heat the water in the tank by the immersion heater up to a temperature of about below
90 C.
b) The disc D is removed before pouring the hot water in the jacket.
c) The hot water is poured in the water jacket.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
107
d) The hemispherical enclosure B and A will come to some Uniform temperature in a
short time after filling the hot water in the jacket. The thermal inertia of hot water is
quite adequate to prevent significant cooling in the time required to conduct the
experiment.
e) The disc D is now inserted in A at a time when its temperature is TD.
f) Start noting the temperature change for every five second for a minute.
7. Specifications Hemispherical enclosure diameter = 200 mm
Base plate, Bakelite diameter = 250 mm.
No. of Temperature Sensor mounted on B = 1
No. of Temperature Sensor mounted on D = 1
Temperature indicator digital (RTD PT-100) = 0-199.90C
Immersion water heater of suitable capacity and tank for hot water = 1.5 KW
The surface of B and A forming the enclosure are black to make their absorptivity to be
approximately unity. The copper surface of the disc D is also blacked.
8. Observations & Calculations
8.1 Data
Mass of water in the hemispherical tank : 5.1x10-3
kg
Specific heat of water : 4180 J/kg K
Area of the disc, AD : 3.14x10-3
m2
8.2 Observation Table
Time t (second) Temperature TD in ºC
5
10
15
20
25
30
8.3 Calculation
The radiation energy falling on D from the enclosure is given by
The emissivity of the disc D is taken as unity, (assuming black disc). The radiant energy disc
D is emitting into enclosure will be
Net heat input to disc D per unit time is given by subtracting both the equations,
If the disc D has a mass m and specific heat s then a short time after D is inserted in A,
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
108
In this equation
denotes the rate of rise of temperature of the disc D at the instant
when its temperature is TD and will vary with time. It is clearly measured at time t = 0
before heat conducted from A to D begins to have any significant effect. This is obtained
from plot of temperature rise of D with respect to time and obtaining its slope at t = 0 when
temperature is TD. The temperature sensor mounted on disc is to be used for this purpose.
Note that the disc D with its sleeve is placed quickly in position and start recording the
temperature at fixed time intervals. The whole process must be completed in 30 seconds of
time. Longer disc D is left in position the greater is the probability of errors due to heat
convection from A to D.
Temperature of water : ____0C
Temperature of hemispherical enclosure at A, T : ____ 0C
Temperature of disc at the instant when it is inserted at D, TD : ____ 0C
Temperature time response of the disc. Note down the temperature TD at the time interval of
5 second. Plot the graph of TD and time (in seconds).
Obtain from the graph,
Value of can be obtained by using,
Nomenclature:
AD = Area of disc D.
T = Temperature of enclosure
TD = Temperature of disc
m = mass of disc
s = specific heat of the disc material.
9. Precautions & Maintenance Instructions
a) Always use clean water and heater should be completely dipped in the water before
switch ON the heater.
b) Always take the reading for the first minute after fixing the disc.
c) Use the stabilize AC single phase supply.
d) Never switch on mains power supply before ensuring that all the ON/OFF switches
given on the panel are at OFF position.
e) Voltage to heater should be constant.
f) Keep all the assembly undisturbed.
g) Never run the apparatus if power supply is less than 180 V and above than 240 V.
h) Operate selector switch of temperature indicator gently.
i) Always keep the apparatus free from dust.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
109
j) Don’t switch ON the heater before filling the water into the bath.
10. Troubleshooting
1. If electric panel is not showing the input on the mains light. Check the fuse and also
check the main supply.
2. If digital temperature indicator displays “1” on the screen check the computer socket
if loose tight it.
3. If temperature of any sensor is not displayed in digital temperature indicator check the
connection and rectify that.
References
5. Holman, J.P., “Heat Transfer”, 8th
ed., pp. 396, McGraw Hill, NY, 1976.
6. Kern, D.Q., “Process Heat Transfer”, 1st ed., pp. 69, 74, McGraw Hill, NY, 1965.
7. Perry, R.H., Green, D.(editors), “Perry’s Chemical Engineers’ Handbook”, 6th
ed., pp.
10/53, McGraw Hill, NY, 1985.
8. Coulson, J.M., Richardson, J.F., “Coulson & Richardson’s Chemical Engineering
Vol. - 1”, 5th
ed., pp. 390, Asian Books ltd., ND, 1996.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
110
EXPERIMENT NO. 12
CROSS-CIRCULATION DRYING
1. Aim
Study of drying characteristics of porous and non-porous solids under forced draft condition
with cross flow of air.
2. Objectives 1. To determine the critical moisture content.
2. To calculate the total drying time.
3. To calculate the humidity of inlet and outlet air with respect to drying time.
3. Theory Drying of solid generally means the removal of relatively small amounts of a liquid from the
solid material to reduce the liquid content to an acceptably low value. There are various
modes of drying a material in various types of dryers. In the present experiment, we study the
cross-circulation drying in an adiabatic or direct dryer. In this case, hot gas (air) is blown over
a bed of wet solids (brick particles wetted with water) under constant drying conditions by
maintaining the temperature, humidity and the velocity of the air across the drying surface
constant. A drying curve is then obtained by plotting drying rate against moisture content of
the solid. In drying, it is necessary to remove free moisture from the surface and also
moisture from the interior of the material. Thus there is interplay of the surface evaporation,
inter-particle and intra-particle diffusion processes during the drying of a material. This gives
rise to several distinct periods in the drying curve as the moisture content of the solid is
reduced from the high initial value to its final value, as explained below in terms of different
periods:
I0 (Initial Period): An initial period during which the drying rate may increase or decrease
rapidly from an initial value and the drying conditions are adjusting themselves to the steady
state condition, which is the next period. This period is of relatively short duration and in
some experiments may be unobservable. Therefore, this period is neglected in the
mathematical analysis of the process.
I (Constant Rate Period): An early stage of drying during which the drying rate remains at a
constant value, that is, is independent of the moisture content. During the constant rate
period, it is assumed that drying takes place from a saturated surface of the material by
diffusion of the water vapor through a stationary air film into the air stream. This period may
be absent if the initial moisture content of the solid is less than a certain minimum.
II (Falling Rate Period 1): During this period, there is insufficient water on the surface to
maintain a continuous film of water. The entire surface is no longer wetted, and wetted area
continually decreases in this first falling-rate period until the surface is completely dry.
During this period, the drying rate decreases more or less linearly with continued decrease of
water content.
III (Falling Rate Period 2): This second falling-rate period begins when it may be assumed
that the surface is dry. In this period evaporation will be taking place from within the solid
and the vapor reaches the surface by molecular diffusion through the material. The drying
rate in this zone decreases further, but generally in a non-linear fashion with the moisture
content.
The moisture content at which the drying rate falls for the first time is the first critical
moisture content, and the moisture content at which the drying rate falls for the second time
is the second critical moisture content. In case of non-porous solids, due to the absence of
intra-particle moisture and hence intra-particle diffusion, the constant-rate period is followed
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
111
by only one falling rate-period so that there is only one critical moisture content (see McCabe
et al., 2001, for detail).
Drying continues until equilibrium moisture content in the solid is attained. Nature of the
drying curve depends on the nature of the solid (porous or non-porous), and the temperature,
humidity and flow rate of the drying medium.
The total time of drying, tT, is determined from the following equation (the derivation is
given in McCabe et al., 2001)
2
1 ln)(X
XXXX
AR
mt c
cc
c
sT (1)
Where,
ms = mass of bone-dry solid
A = area of drying
Rc = rate at first critical point
X = free-moisture content, mass of water per unit mass of dry solid
Xc = free-moisture content at first critical point
X1 = initial free-moisture content
X2 = final free-moisture content
Free moisture content, X, is given by
XXX T (2)
Where,
XT = total free-moisture content
X* = equilibrium free-moisture content
The equilibrium moisture content of a non-porous insoluble material is practically zero so
that the whole moisture content is free moisture.
4. Experimental Setup
4.1. Requirements Dryer assembly, blower, beaker, water, brick particles (porous), glass beads (non-porous),
heater, physical balance, digital anemometer, thermometers (4 in number).
4.2. Schematic Diagram of Experimental Setup
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
112
Outlet of air
Valve Blower
Anemometer
Measurement
space
Inlet of air
Wet bulb
temperature
thermometer Dry bulb
temperature
thermometer
Dryer
Heater
5. Experimental Procedure 1. Weigh the empty pan of the dryer.
2. Take out the pan from the dryer, and after filling it with about 250 gm of brick particles
place it back in the drying chamber. Note the weight of the pan with its contents.
3. Take out the water-cups for wet-bulb temperature (WBT) thermometer from the dryer and
keep them aside. Inject water in the water-cups using a 5 ml-pipette after every 30
minute.
4. Switch on the heater and the blower. Adjust the valve on the inlet line to give a constant
air velocity at about 4 m/s. Measure the air velocity with the digital anemometer.
5. Keep blowing the air for about 30 minutes for the system to reach a steady state, which is
indicated by an insignificant change in the weight of the filled pan. Note the dry-bulb
temperature and the weight of the pan at this state.
6. Take out the pan from the dryer and soak the brick particles in water for about 10 minutes
in a beaker. Then spread the wet brick particles over the pan uniformly. Fill the cups of
the WBT thermometers with water and wrap wet cotton around the bulb of these
thermometers.
7. Put one cup in the cup-holder and one WBT thermometer each at the inlet and outlet ports
of the dryer. Ensure that the bulb of the thermometer remains dipped in the cup.
8. Place the pan back in the drying chamber.
9. Note: Step 8 should follow step 7 with very little time gap.
10. Record the dry-bulb and wet-bulb temperatures at the inlet and the outlet of the dryer, and
weight of the pan. These are the reading at time t = 0.
11. Record the dry-bulb and wet-bulb temperatures at the inlet and the outlet of the dryer and
the weight of the pan, initially at intervals of about 2 minutes, and later at intervals of
about 5 minutes as the rate of drying (indicated by the rate of change of the weight of the
pan) decreases.
12. Continue the run until there is no significant change in the weight of the pan (and so the
temperatures; also the pan plus solid would weigh almost the same as the one noted in
step 5 before wetting the particles).
13. Repeat the experiment with the glass beads at the two air velocities of about 2 and 4 m/s.
6. Observations 1. Surface area of pan = 0.0245 m
2
2. Air velocity =
3. Weight of pan, w1 =
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
113
4. Weight of (pan + dry brick particles), w2 (at step 5) =
Material (glass beads/brick particles):
S No Time Weight of pan and
wet solid, w3
Inlet temperature Outlet Temperature
Dry-bulb Wet-bulb Dry-bulb Wet-bulb
7. Model Calculations
1. Calculate the total moisture content (XT) as (w3 – w2)/(w2 - w1), and plot it with time.
2. Determine the rate of drying by finding the slope of the XT vs. t curve at different times.
(Truly speaking, in case of porous brick particles, one should find the equilibrium
moisture content and then determine the rate of drying using the free moisture content;
since it is difficult to find the equilibrium moisture content [why?], we are working with
the total moisture content).
3. Make the drying-curve by plotting rate of drying vs. moisture content.
4. Find the critical moisture content(s) and the corresponding drying rate(s) from the drying
curve.
5. Check the equilibrium moisture content of glass beads.
6. Using Eq. 1 calculate the total time of drying.
7. Compute the humidity of the air at the inlet and the outlet of the dryer at 5 minutes
interval and plot it against time at inlet and outlet.
8. Results & Discussion
(Tables, Graphs, Comparison with those reported in literature)
9. Conclusions
10. Precautions
Reference 1. Warren, L McCabe, Smith, J C , and Harriott, P, Unit Operations of Chemical Engineering,
6th
edition, McGraw Hill, New Delhi, India, 2000.
2. Richardson, J F, Harker, J H and Backhurst, J R, Coulson and Richardson's Chemical
Engineering, 5th
edition, Vol-2, Asian Books Private Limited, New Delhi, India, 2002.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
114
EXPERIMENT NO. 13(a)
OPEN PAN EVAPORATOR
1. Aim
To determine the overall heat transfer coefficient and the economy of Open Pan Evaporator
when evaporating saturated sodium chloride brine.
2. Theory
Evaporation is a process for concentrating a solution by vaporizing part or all of the solvent-
usually water. The objective of the evaporation is to concentrate a solution consisting of a
nonvolatile solute and a volatile solvent. Essentially, evaporation may be considered to be a
special case of heat transfer in which heat is transferred from condensing vapors, from hot
gases, or directly by radiation to a liquid at constant temperature, usually its boiling point at
the operating pressure. By far the most common evaporators are those in which heat is
transferred through a metal wall from condensing steam to a boiling liquid.
Evaporation differs from the drying in that the residue is a liquid sometimes a highly viscous
one rather than a solid. It differs from the distillation, in that the vapor usually is a mixture,
no attempt is made in the evaporation step to separate the vapor into fractions. It differs from
the crystallization in that emphasis placed on concentrating a solution, e.g. in the evaporation
of brine to produce common salt, the line between evaporation and crystallization is far from
the sharp. Evaporation sometimes produces slurry of crystals in saturated mother liquor.
Normally, in evaporation the thick liquor is the valuable product and the vapor is condensed
and discarded. In one specific situation, however, the reverse is true. Mineral – bearing water
often is evaporated to give a solid – free product for boiler feed, for special process
requirements, or for human consumption. This technique is often called water distillation, but
technically it is evaporation.
The vapor coming out of evaporator can be used as heating media for another evaporator
which will be operating at pressure lower than the pressure in the evaporator from which
vapors are issuing so as to provide sufficient temperature gradient for heat transfer in that
evaporator. When single evaporator is put into service and vapors leaving the evaporator are
condensed and discarded, the method is known as single effect evaporation. The economy of
single effect evaporator is always less than one. Generally for evaporation of one kg of water
from a solution, 1 to 1.3 kg of steam is required.
3. Procedure
a) Prepare approximately 11.6 kg of saturated sodium chloride brine (20 % w/w).
b) Charge this material to the open pan evaporator with bottom drain valve in closed
position.
c) Open the steam supply valve and also the steam to flow to the steam jacket, collect
the condensate in a separate vessel. Also note down the pressure indicated by the
pressure gauge.
d) After an hour stop the steam supply and measure the volume of condensate collected
as well as temperature of the boiling liquor.
e) Open the bottom drain valve of an evaporator and weigh the concentrate of sodium
chloride.
f) Wash the open pan evaporator to remove any traces of sodium chloride.
4. Observation and Calculation
4.1 Observations:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
115
Initial weight of saturated sodium chloride brine (20% w/w) taken = 11.6 kg
Final weight of saturated sodium chloride brine = ------kg
Time of operation () = 1hr
Pressure of the steam supplied to the steam jacket (P) = 0.5 kg/ cm2
Temperature of boiling liquid (T2) = -------- C
Temp. of steam inlet (T1) = --------C
Temp. of condensate (T3) = --------C
Amount of condensate collected (w) = ------kg
Latent heat of vaporization of steam at the given pressure from steam table ()
=-------- kcal/ kg
4.2 Calculations
1) Amount of water evaporated (m)
= (Initial wt. of satd. NaCl brine (20% w/w) taken –
Final weight of satd. NaCl brine)
= -------- kg
2) Total energy given up by the steam to the brine solution (Q)
= * w
= -------kcal
3) Overall Heat Transfer Coefficient (U):
Q/ = U * A * (T1 – T2)
Where, Q/ = heat transferred, kcal/ hr
A= area of heat transfer surface, m2
t2 = temperature of condensing steam, C
t1 = temperature of boiling liquor, C
U = ----------- Kcal / Hr m2 OC
4) Economy, kg of water evaporated per kg steam
= (m/ w)* 100
5. Result
1) Overall Heat Transfer Coefficient (U) =--------- Kcal / Hr m2 OC
2) Economy, kg of water evaporated per kg steam =---------
6. Conclusion
7. Precaution
Keep partially open the steam trap valve during the performance of an experiment for
keeping the flow of steam continuous.
Do not increase the pressure above 1.5 kg/cm2 in steam generator.
Circulate the water in pipes after completion of an experiment to avoid the chocking
of solids inside the pipeline.
Drain the water from steam generator and condensate collector after completion of an
experiment.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
116
Operate gently the selector switch of temperature indicator to read various
temperatures.
Increase the temperature gradually of the heater during initial set-up experimentation.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
117
EXPERIMENT NO. 13(b)
VAPOR IN AIR DIFFUSION
1. Aim
To determine the diffusion coefficient of acetone (liquid) in air by using Arnold's cell.
2. Theory
Diffusion describes the spread of particles through random motion from regions of higher
concentration to regions of lower concentration. The time dependence of the statistical
distribution in space is given by the diffusion equation. The concept of diffusion is tied to that
of mass transfer driven by a concentration gradient, but diffusion can still occur when there is
no concentration gradient (but there will be no net flux). If two gases are inter diffusing with
continual supply of fresh gas and removal of the products of diffusion, this diffusion reaches
an equilibrium state with constant concentration gradients. This is known as steady state
diffusion. If also there is no total flow in either direction the rates of diffusion of A and B, NA
and NB are equal but have opposite sign.
The diffusivity or diffusion coefficient, D is a property of the system dependent upon
temperature, pressure and nature of the components. The dimension is length2/time.
This is the case of pseudo-steady-state diffusion in which one of the boundaries shift with
time with the effect that the length of the diffusion path changes, though only by a small
amount over a long period of exposure.
When this condition exists:
---------- (1)
The molar flux at any instant in the gas phase
Where Z=z1-z2 = the length of the diffusion path in time t.
3. Experimental Setup
3.1 Apparatus: Arnold's cell, Thermometer, Scale
3.2 Chemicals: Acetone.
4. Experimental Procedure
a) Acetone is filled in capillary tube and air bubble, if present, is removed from the tube
carefully.
b) Note down the initial height (H0) of the acetone level in the tube.
c) The tube is placed in a water bath to maintain the constant temperature. Note down
the temperature of the water by thermometer.
d) Switch on blower, which blown air across the opening of capillary tube continuously
to remove the vapors evaporated that rises from the surface of the liquid.
21
,
,
1AA
lmB
AB
ZAPP
PRT
P
Z
D
N
2
1
2,
21
, 2
11zz
MtPP
PRT
PD t
LA
AA
lmB
AB
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
118
e) At regular interval of time note down the drop in the level of acetone.
f) Do necessary calculations and find out the diffusivity (D) from the equation.
g) Also calculate the diffusivity from the GILLILAND’S equation (as shown below) at
the same temperature using standard data and compare the result with the
experimental one.
h) Repeat the same procedure for two-three different temperatures by increasing and
maintaining constant temperature of the water bath and calculate the diffusivity by
both the methods. State your conclusion precisely at the end.
9. Observation Table
S.No Temp
c
Initial ht. of
liquid (mm)
Final ht. of
liquid(mm)
Time
(sec.)
1
2
3
6. Calculation a) Vapor pressure of acetone at given temp. (Calculate by Antoine Equation)
b) PA1 = ______ mm hg (Convert to N/m2, 1mmhg=133.2 N/m
2 )
c) PB1 = P-PA1
d) PA2 = 0 ( Pure B(air) is flowing)
e) PB2 = P-PA2
f) Z1 = ____________ m , Zt =_______ m
g) Diffusivity is given by,
DAB = __________ m2 /sec
7. Diffusivity by Gilliland’s method
VA = Molar volume of acetone = 0.0074 m3/kmol
VB = Molar volume of air = 0.01386 m3/kmol
MA = Molecular weight of acetone = 58 kg/kmol
1
2
12
,
lnB
B
BB
lmB
P
P
PPP
23/13/1
2/12/34
*
/1/110*3.4
BA
BA
VVP
MMTD
2
1
2,
21
, 2
11zz
MtPP
PRT
PD t
LA
AA
lmB
AB
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
119
MB = Molecular weight of air = 18 kg/kmol
T = Absolute temperature = __________ 0
K
So,
D = __________ m 2
/sec from Gilliland’s eqn.
8. Data Given
a) P= 1 Std.atm. = 760 mm hg = 101325 N/m2
b) R = 8314 N.m/Kmol. K
c) Room Temp = ______ C
d) Density of acetone = 1540 Kg/m3
e) Mol. of acetone = 58 Kg/Kmol.
Antoine Constant For acetone
f) A = 16.6513
g) B = 2940.46
h) C = - 35.93
9. Result
Temperature (K) DAB DTheo.
10. Conclusion
Observe and state the effect of Temperature on Diffusion.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
120
EXPERIMENT NO. 14
DIFFERENTIAL DISTILLATION
1. Aim
To verify the Raleigh’s equation for a differential distillation in a binary system and to
estimate relative volatility of the binary system
2. Introduction
Differential distillation is also known as simple distillation. Usually it is operated in a batch
mode. It is used to separate a liquid mixture whose components have fairly large difference in
their boiling points. In this mode of distillation a charge of liquid is placed in the still and it is
distilled off until the liquid charged is all gone or until the operation is no longer doing any
beneficial separating. In batch distillation operations, the liquid in the original charge is
constantly being depleted of its more volatile components. This mode of distillation may also
be used for analytical evaluation of boiling ranges and vaporization characteristics if mixtures
in laboratories.
3. Theory
Differential distillation refers to a batch distillation in which only one vaporization sate is
involved. Lard Rayleigh developed a mathematical equation which represents differential
distillation. The following are the major assumptions in deriving Rayleigh’s equation
1. Still liquid composition is uniform.
2. The distillation process is carried out slowly so that the vapour leaving the still is in
equilibrium with the liquid in still.
3. There is no entrainment of the liquid during the distillation
4. There is no condensation of the vapour evolved before it reaches the condenser.
3.1 Rayleigh’s equation derivation
Let L be the number of moles of the mixture at a given instant. Let x be the mole fraction of
more volatile component in liquid mixture. Let y be the mole fraction of more volatile
component in vapour that is in equilibrium with liquid that is in still. If dL is the differential
amount of liquid vaporized then by applying the material balance with respect to the more
volatile component we get
Input = Lx (1.1)
Output = dLy (1.2)
Accumulation = dxxdLL (1.3)
Therefore dLydxxdLLLx (1.4)
Neglecting dLdx , we get
LdxxdLdLy (1.5)
Therefore, xy
dx
L
dL
(1.6)
The boundary conditions are:
Initially, L = F and Fxx ; F : moles of feed mixture
Finally, L = W and Wxx ; W : moles of with drawn or bottom mixture
W
F
x
x
W
Fxy
dx
L
dL (1.7)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
121
T
W
x
xxy
dx
W
Fln (1.8)
Using the vapour liquid equilibrium data for the binary mixture system, the plot is made of
xy
1 vs x .Area under the curve between the ordinate at Fx and Wx gives the values of
the integral on the R.H.S of Eq.(1.8). From this we obtain the value of W, the amount of with
drawn (or) bottoms, to be left to attain the given composition Wx of the liquid. Alternatively,
if we want to calculate the composition of with drawn, when W is known, then L.H.S of
Eq.(1.8) can be found and value of Wx adjusted to obtain the area under the curve equal to the
value of W
Fln .
3.2 Rayleigh’s equation for an ideal system
For an ideal system, average relative volatility, ave , is constant. Therefore for an ideal
system we can write the following equilibrium relation
x1α1
xαy
ave
ave
(1.9)
Substituting Eq.(1.9) in Eq.(1.8) and upon manipulation we get the following relation
W
Fave
W
F
x1W
x1Flnα
Wx
Fxln (1.10)
Eqs.(1.8) and (1.10) are known as Rayleigh’s equations for differential distillation.
4. Experimental setup
The experimental setup to study differential distillation is shown in Figure P1.1. The
distillation still may be fabricated from steel with substantial thickness recommended. The
vapors of the chemical distilled are collected as distillate is shown in the Figure P1.1.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
122
Figure P1.1. Differential distillation experimental setup
5. Experimental procedure
The following procedure may be followed while conducting the experiment
1. The still is charged with known composition binary system
2. Ensure water flow in the condenser
3. Heating mantle is switched on and heating is carried out sufficiently and slowly.
When the mixture starts boiling, collect the distillate in a flask.
4. This procedure is continued for sufficient length of time (say 2hours) until
approximately 2/3 of the feed distilled.
5. Meantime prepare a calibration chart using known concentrations for the binary
system. For calibration purpose use specific gravity technique (or) refractive index
(RI) method.
6. Measure the specific gravity of the distillate (or) RI of the distillate. Similarly cool the
bottoms to room temperature and measure specific gravity (or) RI of bottoms
6. System used and calculations
The Following binary Chemical may be taken for simple distillation
Ethanol (A)-water (B)
Data required for the calculations from the literature
1. Molecular weights of compounds A and B
2. Densities of components A and B (or) refractive indices of components A and B
3. Vapour- liquid equilibrium (VLE) of components A and B at atmospheric pressure
4. Plot calibration chart
7. Calculations
1. Calculate the amounts and compositions of distillate for the sample i.e D and Dx .
While doing make use of calibration plot for composition calculations.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
123
2. Using total material balance and more volatile component balances to calculate
amount of residue (bottom),W and composition of the residue, Wx
3. Plot xy
1
vs. x and measure the area between the curve and x-axis to the left of
the ordinate Fxx ,when the area = F/Wln , final Wx
4. Calculate
100
WFln
xydxF/Wln
F
W
x
x
5. Using
W
Fave
W
F
x1W
x1Flnα
Wx
Fxln estimate aveα
8. Presentation of results
1. Mole fraction of mole volatile component in the feed; mole fraction of more volatile
component in the distillate; mole fraction of more volatile component in the bottoms
2. Amounts of distillate and bottoms and their compositions
3. aveα = average relative volatility of the system between Wx and Fx
4. Report % errors
5. One can also compare estimated aveα value with the value obtain with the help of
equilibrium data. Make use the definition of α as
x1x
y1y
α and then calculate aveα
.
6. Using
W
Fave
W
F
x1W
x1Flnα
Wx
Fxln estimate aveα
VLE DATA ETHANOL WATER SYSTEM
x y* x y* 0.0 0.0 32.73 58.26
1.9 17 39.65 61.22
7.21 38.91 50.79 65.64
9.66 43.75 51.98 65.99
12.38 47.04 57.32 68.41
16.61 50.89 67.63 73.85
23.37 54.45 74.72 78.15
26.08 55.8 89.43 89.43
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
124
CALIBRATION CHART
References:
1. Max Peters, “Elementary Chemical Engineering”, 2nd
ed, McGraw-Hill Book
Company, New York, 1984, pp. 203-204.
2. V.G.Pangarkar and R.R.bhave, “Mass transfer Operations: A laboratory manual in
Chemical Engineering”, Chemical Engineering Education Development Centre,
Indian Institute of Technology Madras, Madras, 1981, pp.20-26.
3. R..E.Treybal, Mass Transfer Operations, McGraw-Hill Book Company, 3rd
ed, New
York, 1984, pp. 367-370.
4. F.Molyneux, Laboratory exercises in Chemical Engineering, Leonard Hill Books,
London, 1967, p.137.
5. ‘Chemical Engineering Laboratory Manual’ published by IIT Bombay, obtained on
the Webpage http://www.che.iitb.ac.in/courses/uglab/uglabs.html accessed on
25.08.2011
1.33
1.335
1.34
1.345
1.35
1.355
1.36
0 0.1 0.2 0.3 0.4 0.5 0.6
Re
frac
tive
Ind
ex
Mole fraction of Ethanol in Ethanol-Water System
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
125
EXPERIMENT NO. 15
BATCH CRYSTALLIZATION
1. Aim
Determine the yield of crystals using agitated batch crystallizer.
2. Objective
To study the yield of crystals of Sodium Sulfate (Na2SO4) or Sodium Chloride (NaCl) from
its saturated solution using open tank type agitated batch crystallizer.
3. Theory
Crystallization is an important operation in processing as a method of both purification and of
providing crystalline materials in a desired size range. In a crystal, the constituent molecules,
ions or atoms are arranged in a regular manner with the result that the crystal shape is
independent of size and, if a crystal grows, each of the faces develops in regular manner. The
presence of impurities will, however, usually result in the formation of an irregular crystal.
Generally large regular crystals are a guarantee of the purity of the material, though a number
of pairs of materials form “mixed crystals”. In recent years, techniques have been developed
for growing perfect crystals, which are used in the production of semiconductor devices, laser
beams, and artificial gems.
The crystallization process consists essentially of two stages which generally proceed
simultaneously, but which can to some extent be independently controlled. The first stage is
the formation of small particles or nuclei, which must exist in the solution before
crystallization can start, and the second stage is the growth of nuclei. If the number of nuclei
can be controlled, the size of the crystals ultimately formed may be regulated, and this forms
one of the most important features of the crystallization process.
Yield of crystals: The yield of crystals produced by a given cooling may be estimated from
the concentration of the initial solution and the solubility at the final temperature, allowing
for any evaporation, by making solvent and solute balances as follows:
For the solvent, usually water, the initial solvent present is equal to the sum of the final
solvent in the mother liquor, the water of crystallization within the crystals and any water
evaporated or:
w1 = w2 + y(R-1)/ R + w1E ------------------- (i)
Where,
w1 and w2 are the initial and final masses of solvent in the liquor
y is the yield of crystals
R is the ratio (molecular weight of hydrate/ molecular weight of anhydrous salt)
And E is the ratio (mass of solvent evaporated/ mass of solvent in the initial solution)
For the solute:
w1c1 = w2c2 + y/ R ---------------------- (ii)
Where,
c1 and c2 are the initial and final concentrations of the solution in the terms of mass of
anhydrous salt per unit mass of solvent.
From equation (1):
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
126
w2 = w1(1 – E) – y(R - 1)/ R ---------------------- (iii)
And in equation (2)
w1c1 = c2 [w1(1 – E) – y(R - 1)/ R] + y/ R ----------------------- (iv)
From which the yield,
y = Rw1[c1 – c2 (1 – E)]/ [1 – c2(R-1)] ------------------------ (v)
Broadly, crystallizers may be classified according to whether they are batch or continuous in
operation, and continuous crystallizers may be divided into linear and stirred types which are
referred to later. Crystallizers may also be classified according to which the super saturation
is achieved. In evaporative crystallizers conditions are approximately isothermal, and super
saturation is achieved as a result of the removal of solvent. In cooling crystallizers, super
saturation results from lowering of the temperature of the solution, and this can be effected
either by means of exchange of sensible heat or by evaporative cooling; in the latter case,
there is a small loss of solvent. Evaporative crystallization must of course be used where the
solubility shows little variation with temperature.
The simplest and cheapest type of crystallizer consists of an open tank, which can be used
either as an evaporative or as a cooling crystallizer. In small scale of batch processing, such
crystallizers are quire convenient because of their low first cost, simplicity of operation and
flexibility. They are too wasteful of labor and give too uneven product to be attractive for
large scale continuous processing
4. Experimental Set-up
The experimental setup has a 5 liter capacity jacketed vessel made of SS 304, 1.6 mm thick,
provided with a FHP variable speed std. make stirrer (Gear Motor, 150 RPM max., for better
control of stirring and revolving the stirrer at low RPM during crystallization).
5. Experimental Procedure
a) Take about 3-4 liter of water in the unit. Switch ON the power supply and pump and
start circulating the water from the tank in to the jacket at fixed value using the
rotameter. The exit water from the jacket shall be recycled back to the water supply
tank.
b) Set the temperature of the crystallizer content using the front panel of the
Temperature Indicator-Controller (TIC) to the desired value and slowly start adding
the solid to be crystallized and allow it to dissolve completely.
c) Now set the temperature value of the crystallizer on the TIC to the value
corresponding to the value at which the crystallization is to be carried out.
d) Reduce the rate of circulation of hot water in the jacket and maintain it in the range of
about 1.5-2.0 LPM and start draining the water coming out of the jacket.
e) Add the cooling water available in the laboratory at the same rate to the water supply
tank to make up the loss of water in the water supply tank and start recycling the exit
water from the jacket back to the water supply tank.
f) If ice addition is required to bring down the temperature of the Crystallizer obtained
by the cooling water alone, slowly add finely crushed ice to the water supply tank so
that the temperature of the crystallizer do not go below the set value.
g) After 10-15 minutes stop circulation of the cold water and drain the water from the
crystallizer using drain valve.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
127
h) Filter and then weigh the water and crystals collected. Collect the crystals from the
crystallizer. Dry them and weigh.
6. Observations and Calculations
T1 = hot water inlet temperature / cold water inlet temperature
T2= hot water outlet temperature / cold water outlet temperature
T3=sample liquid inner temperature
T4=sample liquid outlet temperature (if required)
Initial weight of water taken (w1) = gm
Initial weight of Na2so4 added (m1) = gm
Temperature at which dissolution takes place(t3) = C
Final weight of Na2so4 collected (m2) = gm
Final Cooling Temperature = C
% Yield of crystals = (m2 /Solubility at exp. Temp.) * 100
Yield of crystal = Wt. of Na2so4 obtained as crystals
Wt. of Na2so4 initially taken in feed
7. Result & Discussions
i) Yield of crystals =
ii) Plot the Solubility Curve of Na2SO4 in Water with Temperature
8. Conclusion
9. Precautions
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
128
EXPERIMENT NO. 16(a)
STEAM DISTILLATION SETUP
1. Aim
To study the characteristics of simple steam distillation using turpentine oil as a feed stock.
2. Objective
To determine the vaporization efficiency, thermal efficiency and percentage recovery of
simple steam distillation.
3. Theory
Steam Distillation is a term used to describe a distillation process with open steam. Steam
distillation is a method for distilling compounds which are heat-sensitive. It is specifically
used where it is desired to separate substances at a temperature lower than their normal
boiling point. The temperature of the steam is easier to control than the surface of a heating
element, and allows a high rate of heat transfer without heating at a very high temperature.
The vapor mixture is cooled and condensed, usually yielding a layer of oil and a layer of
water.
Steam distillation is commonly used in the following situations:
1. To separate relatively small amounts of volatile impurity from a large amount of
material
2. To separate appreciable quantities of higher-boiling materials
3. To recover high-boiling materials from small amounts of impurity that has a higher
boiling point.
4. Where the material to be distilled is thermally unstable or reacts with other
components associated with it at the boiling temperature
5. Where the material cannot be distilled by indirect heating even under low pressure
because of the high boiling temperature
6. Where direct-fired heaters cannot be used because of fire hazards
In a steam distillation process, the liquid is distilled by feeding open steam to the distillation
still. The steam carries with it vapors of volatile liquid and is then condensed to separate the
liquid from water. The essential requirement for carrying out steam distillation is:
1. Substance does not react with steam.
2. Substance is in-soluble in water (immiscible).
From the Hausbrand vapor pressure diagram for turpentine water system at 101.3 kN/m2
pressure, obtain the distillation temperature, TD oC ( 95°C).
From the Hausbrand diagram, curves for turpentine and water at atmospheric pressure cross
at 95°C.
Distillation: Turpentine oil at 101.3 kN/m2 pressure, (1.03kg/cm²) .The intersection of the
two curves gives the distillation temperature.
Figure 1: Plot of PA Vs T and
(101.3 - PB) Vs T.
Distillation Temp.
VapourPressure
T
(101.3 - P )BPA
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
129
Figure 2: Hausbrand vapor-pressure diagram for turpentine oil-water system
4. Experimental Setup
4.1 Description
The apparatus consists of simple batch distillation using steam as a source of heat. The feed
stock used is turpentine oil. Distillate is collected in a separating funnel for the formation of
organic layer and an aqueous layer. Experimental Setup is shown in Fig 3.
Fig 3: Experimental Setup
4.2. Requirements
(Turpentine Oil + Water)
PG
Jacket
Steam
Live
Steam
Turpentine oil In
Water In
Residue Out
Distillate
Cooling Water Out Cooling Water In
Condenser
Heater
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
130
Steam supply, electricity, turpentine oil, demineralized water and separating funnel
5. Experimental Procedure
1. Charge the distillation still with 2kg of turpentine oil.
2. Adjust the jacket steam pressure to 170 kN/m2 (Pg,)/1.73 kg/cm² and start the cooling
water supply to the condenser. Record the still temp. Collect the steam condensed in
the jacket.
3. When the temperature in the still reaches 2°C below the distillation temp. (Td), the
jacket steam is stopped and the flow of live steam is started through the steam sparger.
4. The live steam pressure is adjusted around 150 kN/m2 (Ps) /1.52 kg/cm².
5. Weigh the steam condensed in the jacket (WS), kg.
6. Continue the distillation process for sufficient time so that about 50-70% turpentine
charged is distilled (around 1 hr).
7. Stop the steam supply and collect the distillate in the 2L separating funnel. Allow the
formation of organic layer and an aqueous layer. Separate the two phases and weigh
them, (WAD, WBD), kg.
8. Collect the residue, separate the two layers and weigh WAB, WBB (kg).
9. Stop the water supply to the condenser.
6. Observations and Calculation
Mol. Wt. of turpentine oil MA =136.22
Normal boiling point of turpentine oil = 160oC
Sp. heat of turpentine oil at 20°C = CpA = 1.8 kJ/kg °C
Sp. heat of turpentine oil at 50°C = CpA =1.926 kJ/kg °C
Sp. heat of turpentine oil at 100°C = CpA = 2.093 kJ/kg °C
Latent heat of vaporization of turpentine oil, A = 74 kcal/kg = 309.84 kJ/kg
Mol. wt. of Water = MB = 18
System Pressure, P = 101.3 KN/m2
/1.03kg/cm²
Wt. of turpentine (feed) = 2 kg.
Distillation temp., TD = 95 °C
Wt. of Steam Condensed in jacket = WS, kg
Steam pressure in the jacket, Pg = 170 KN/m2
Pressure of live steam, PS = 150 KN/m2
Steam pressure in the jacket = 172.21 kg/m2 = Pg
Live pressure in the still = 151.95 kg/m2 = Ps
Mass of steam condensed during pre-heating (feed change from 23oC to 95
oC) WS = 410 g
Distillation time =
Initial temperature of feed charge, TR = °C
Observed distillation temp., = °C
Distillate readings (Turpentine oil + water):
Wt. of turpentine oil in distillate WAD =
Wt. of water in distillate WBD=
Residue collected (Turpentine oil + water):
Wt. of turpentine oil in residue WAB =
Wt. of water in residue WBB =
Ambient temperature Tr = 23°C
Distillation time = 15 min approximately
Observed distillation temperature =
Converting Weights to moles:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
131
No. of moles of turpentine oil in feed
WAF
NAF = ---------- =
MA
No. of moles of turpentine oil in distillate
WAD
NAD = ---------- =
MA
No. of moles of turpentine oil in Residue
WAB
NAF = ----------- =
MA
No. of moles of water in distillate
WBD
NBD = ------------ =
MB
No. of moles of water in residue
WBB
NBB = ---------- =
MB
Applying Material balance for turpentine oil,
NAF = NAD + NAB
Losses from the still turpentine oil =
Steam Distillation Temp, TD =
PAO= Partial Pressure of turpentine oil during distillation = P [NAD/ (NAD + NBD)]
Where P =total pressure = 101.3 KN/m2
Vaporization efficiency =
PAº
= --------- =
PA
WBD (P - PA) MB
And ---------- = ----------------x ----------
WAD MA
where PA is the pressure of turpentine oil and water system at 95 °C from Hausbrand
diagram.
WBD / WAD in distillate =
% Recovery =
Calculation of Thermal efficiency: T
Total heat output
T = --------------------------------- x 100
Total heat input
Heat Output:
QO = WAF (TD – TR) CpA + A WAD = WS + A WAD
TR = ambient temp
TD = distillation temp. =92oC
Heat Input: Qi
Qi = Heat given by condensing steam in the jacket + Heat given by the condensing live steam
during distillation.
Qi = WSJ + (WBD + WBB) [S + Cp (TS – TD)]
Jacket steam pressure = PJ (KN/m2)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
132
J =latent heat of vaporization of steam corresponding to pressure PJ, kJ/kg
PS = Pressure of live steam, KN/m2
TS = saturation temp. of steam at PS, °C corresponding to PS, kJ/kg
Cp = Specific heat of steam, kJ/kg°C.
PJ = 172 KN/m2
J = 2216 kJ/kg
PS = 151.95 KN/m2
S = 2230 kJ/kg
Cp = Sp. heat of steam = 2.0 kJ/kgoK
QO
= -------- x 100 =
Qi
NOMENCLATURE
WAF = Wt. of turpentine in feed (kg)
TD = Distillation temp. °C
TR = Reference temp. (Ambient temp) °C
Cp = Specific heat of turpentine oil (kJ/kgoC)
A = Latent heat of evaporation of turpentine (kJ/kg)
WAD = Wt. of turpentine in distillate, (kg)
WS = Wt. of Steam Condensed in the jacket during pre-heating
or charge (kg)
= Latent heat of steam corresponding to jacket steam
pressure P (kN/m2)
WBD = Wt. of water in distillate (kg)
WBB = Wt. of water in residue, kg
S = Latent heat of steam at live steam pressure PS (kN/m2)
TS = saturation temperature of steam at PS
Cp = Specific heat of steam (kJ/kgoC)
7. Results and Discussion
Vaporization efficiency=
Recovery=
Thermal efficiency=
8. Conclusion
References
1. McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical
Engineering”, 7th
ed.McGraw Hill, NY, 2005.
2. Coulson, J.M., Richardson, J.F., “Coulson & Richardson’s Chemical Engineering
Vol. - 1”, 5th
ed., Asian Books ltd., ND, 1996.
3. Treybal, R.E., “Mass Transfer Operations”, 3rd
ed., McGraw Hill, NY, 1981.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
133
EXPERIMENT NO. 16(b)
VAPOR LIQUID EQUILIBRIUM SETUP
1. Aim & Objective
Study of vapor-liquid equilibrium of Toluene – CCl4 mixture
2. Apparatus VLE setup consisting of heater, condenser, temperature indicator and refractometer, test
tubes.
3. Chemicals Carbon Tetrachloride, Toluene
4. Theory The design of distillation and other contacting equipment requires reliable VLE data.
Although relatively few ideal solutions are known whose equilibrium relations can be
calculated from vapor pressure - temperature data of the pure components, by far the larger
numbers of systems of industrial importance are non-ideal; and attempt to predict the
equilibrium compositions of such mixtures from theoretical considerations alone have not
proved successful. It has been the practice to determine such data experimentally under
various conditions.
Vapor liquid diagram shows relationship between the composition of the vapor and that of
liquid in equilibrium with the vapor for a binary mixture at constant pressure or constant
temperature. If liquid and vapor behave ideally, such curves are calculated as follows:
From Raoult' law:
p1 = P1 X1 (1)
p2 = P2 X2 (2)
Where p1 and p2 are partial pressures of components 1 and 2 in the mixture, P = total pressure
P1 and P2 are vapor pressure of pure components at the same temperature as mixture.
From Dalton's law of partial pressures:
P1= P y 1 (3)
P2= P y 2 (4)
Where, y1 and y2 are the mole fractions of components in vapor.
From these equations we have:
21
2
1PP
pPx
(5)
P
xPy
21
1 (6)
Theoretical VLE curve can thus be calculated by choosing various boiling points of
themixture and calculate x and y as shown above. Carbon tetrachloride - Toluene system
closely follows ideal behavior.
5. Experimental Procedure
1. The vapor - liquid equilibrium still containing about 15O ml to 200 ml of known
mixture (toluene – CCl4) is heated gently for at least 45 to 60 minutes (to ensure the
mixture has attained equilibrium in above time)
2. The liquid and vapor are then sampled at noted temperature (T) and analyzed for
molar composition of more volatile component in vapor (y) and liquid (x).
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
134
3. The heating is stopped and the feed liquid is replaced by another feed mixture
(increasing gradually the amount of high boiling liquid), the liquid and vapor are once
more allowed to come to equilibrium (indicated by constant temperature) and
collecting the samples of liquid from the still and the condensate. The still liquid
being hot, should be collected in an ice cooled test tube to avoid any change in
composition due to vaporization. The above procedure should be repeated for at least
six feed compositions.
4. The samples are viewed under a high precision refractometer, and their composition
determined from the pre-determined calibration chart for CCl4 - toluene mixture,
which converts refractive index to mole fractions. This way T-x-y and x-y diagrams
can be plotted.
5. The calibration curve (nD vs. mole fraction of more volatile component, x) should be
generated at a specific temperature (say 250C) by taking different mixtures of CCl4 -
toluene of known molar composition and recording the refractive index of the
mixture. The samples collected should also be evaluated at the same temperature.
6. Observation & Calculation
Correlation for CCl4 – Toluene system w.r.t refractive index is given by the equation
y = -27.757*x + 41.529 ------------- (7)
For VLE curve data
S.No Liquid
refractive
index
Mole
fraction
(x)
Vapor
refractive
index
Mole
fraction
(y)
Temperature
(°C)
7. Results & Discussion
Plot the following graphs
1. y vs. x
2. Temperature vs. x
3. Temperature vs. y
8. Conclusion
9. Precautions 1. The still liquid being hot, should be collected in an ice cooled test tube to avoid any
change in composition due to vaporization.
2. The above procedure should be repeated for at least six feed compositions.
References: (a) McCabe, W.L., Smith, J.C., Harriott, P., “Unit Operations of Chemical Engineering”,
7th
ed., McGraw Hill, NY, 2005.
(b) W.L Badger & J.T. Banchero., “Introduction to Chemical Engineering”, 26th
reprint,
McGraw Hill, NY, 2011.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
135
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
136
EXPERIMENT NO. 17
TWO PHASE FLOW IN A HORIZONTAL PIPE
1. Aim To Study Two phase flow in Horizontal Pipe.
2. Objective
To study the two-phase flow in a horizontal pipe and to determine the pressure drop for the
two phase flow.
3. Theory
Concurrent gas-liquid flow is very common in chemical process equipment like reactors, re-
boilers, partial condensers, flash vaporizers gas pipe lines etc. As such it is always important
to have a clear understanding of flow pattern and pressure drop in systems involving a two-
phase mixture.
3.1 Flow Pattern
There are various flow regimes or “patterns” that are common to two phase flow systems,
each having different characteristics and associated pressure drops. Two phase flow cannot
simply be described as laminar, transitional and turbulent. The two-phase patterns vary not
only with flow rates and fluid properties, but also depend upon pipe diameter and inclination.
In horizontal pipe, the two phase flows regimes are (in order of lowest gas velocities to
highest) bubble flow, plug flow, stratified flow, wavy flow, slug flow, annular flow and spray
flow. In vertical pipe there are bubble, slug, churn, ripple, annular flow and mist flow.
Most remediation professionals would recognize the appearance of these four patterns from
conducting pilot tests and from observations gathered during full-scale system operation.
However, most practitioners are unaware of the significance of that the type of flow pattern
has on efficient system effectiveness. (Note: The term” Pattern” refers to visual observations
and the flow “regime” applies to flow behavior that can be described by more quantitative
expressions.
Additionally, general estimations of flow pattern can be made using superficial gas and liquid
velocities (Perry, 1999), Horizontal flow patterns can be roughly determined from gas and
liquid superficial velocities, while vertical patterns can be estimated based on gas velocity
only (Note: Superficial velocity is defined as the velocity of a phase as if it was flowing alone
within the pipe.
In horizontal pipe, flow patterns for fully developed flow have been reported in numerous
studies. Transitions between flow patterns are gradual, and subjective owing to the visual
interpretation of individual investigators. In some cases, statistical analysis of pressure
fluctuations has been used to distinguish flow patterns.
Bubble flow is prevalent at high ratios of liquid to gas flow rates. The gas is dispersed as
bubbles which move at velocity similar to the liquid and tend to concentrate near the top of
the pipe at lower liquid velocities.
Plug flow describes a pattern in which alternate plugs of gas and liquid move along the upper
part of the pipe.
In stratified flow, the liquid flows along the bottom of the pipe and the gas flows over a
smooth liquid/gas interface. Similar to stratified flow, wavy flow occurs at greater gas
velocities and has waves moving in the flow direction. When wave crests are sufficiently
high to bridge the pipe, they form frothy slugs which move at much greater than the average
liquid velocity.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
137
Slug flow can cause severe and sometimes dangerous vibrations in equipment because of
impact of the high-velocity slugs against bends or other fittings. Slugs may also flood
gas/liquid separation equipment.
In annular flow, liquid flows as a thin film along the pipe wall and gas flows in the core.
Some liquid is entrained as droplets in the gas core. At very high gas velocities, nearly all the
liquid is entrained as small droplets. This pattern is called spray, dispersed, or mist flow
When a liquid and gas flows through a horizontal pipe, the following types of flow may
occur.
1. Both the phases may be in viscous region.
2. Both the phases may be in turbulent region.
3. One of the phases may be in turbulent region and the other in viscous region.
The type of flow of each phase is determined by the Reynolds number calculated on the basis
of superficial velocity (superficial velocity = total flow rate of single phase/ total cross
sectional area of flow)
The pressure drop in a two-phase flow is the sum of the pressure drops due to friction and
pressure drop due to acceleration. In a two phase flow, where gas is one of the phases, the
pressure drop due to acceleration is important because the gas normally flows faster than the
liquid phases and thus accelerates the liquid phase resulting in transfer of energy. The
estimation the pressure drop is not possible analytically. The most common method to
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
138
estimate the pressure drop for two-phase flow is the one proposed by Lockhart and Martinelli
(Page 6-26, fluid and particle dynamics, Perry’s chemical engineering). In this, each phase is
considered separately and the combined effect is determined.
Lockhart and Martinelli (ibid.) correlated pressure drop data from pipes 25 mm (1 in) in
diameter or less within about 50 percent.
In general, the predictions are high for stratified, wavy, and slug flows and low for annular
flow. The correlation can be applied to pipe diameters up to about 0.1 m (4 in) with about the
same accuracy.
The pressure drop due to two-phase flow is the pressure drop of either of the two phases if it
alone were present, multiplied by a factor.
(P/Z)tp = YL (P/Z)L
(P/Z)tp = Yg (P/Z)g
where YL and Yg are the functions of dimension less parameter X defined as:
X = [(P/Z)L/(P/Z)g]0.5
The two-phase flow analysis can also be expressed in terms of friction factors.
By definition of pressure drop,
P/Z = (2fV2/(gcD))
Friction factor, f = (P/Z) .g. D/2*V2)
where,
v is the superficial fluid velocity, D is pipe I.D, is the fluid density and P/Z is the
pressure drop per unit length
Thus for gas only:
fg = (P/Z)g .g. D/(2*Vg2g)
for liquid only
fl = (P/Z)l .g. D/(2*Vl2l)
for two phase flow
flpl = (P/Z)tp .g. D/(2*Vl2l) (based on superficial velocity of liquid)
flpg = (P/Z)lp .g. D/(2*Vg2g) (based on superficial velocity of gas)
Defining
g = flpg/fg
l = flpl/fl
X2 = [(P/Z)L / (P/Z)g] = [g / l]2
Two phase pressure drop is then expressed as:
(P/Z)tp = g2 (P/Z)g
(P/Z)tp = g2 (P/Z)l
Friction factors for single component flow (gas or liquid) can be easily estimated from:
f = 16/Re (for Re < 2000)
f = 0.079 (Re)-0.25
(for Re > 3000)
Recently empirical co-relations have been derived from a large data bank for void fraction ()
and g and are given below:-
=__________1_______________
(1+0.0904 X 0.548)2.82
g = (1+ X 2ln
) n/2
and, n is obtained from the table given below:-
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
139
N Liquid Flow Gas Flow
4.12 Turbulent Turbulent
3.61 Viscous Turbulent
3.56 Turbulent Viscous
2.68 Viscous Viscous If X < 1
3.27 Viscous Viscous If X > 1
Pure phase Reynolds numbers are defined as:
Reg = DVg g / g
Rel = DVl l / l
Vl = Superficial velocity of liquid = volumetric flow rate of liquid/cross-section area of
empty pipe.
Vg = Superficial velocity of Gas = volumetric flow rate of gas/cross- section area of
empty pipe.
D is the I.D. of pipe = 25.4mm= 0.0254m
P is the pressure drop across length = Z = 1 meter approximate.
4. Experimental Procedure
8.
9. Start the water pump and allow water to flow at a constant flow rate
10. Start the compressor and fix the air pressure in the air tank at 1.5 kg/cm² and allow air
to flow at some constant flow rate.
11. Wait for the steady state and observe the flow pattern. Record it. Note the volumetric
flow rates of water and air (rotameter readings).
12. Record the average reading of the manometer (cm of CCl4). Also record the
temperature of water and air by thermometer.
13. Increase the gas flow rate gradually keeping water flow rate constant at the previous
level and repeat steps 4 and 5.
14. Repeat step 6 for at least 6 gas flow rates.
15. Repeat steps 2 to 7 for at least 5 liquid flow rates
16. Stop the compressor.
17. Stop the water pump.
5. Observations
System : Air-water
Distance between manometer taps = 1000mm = 1Z, m
Manometer fluid = mercury
Water temperature = T ambient
Air Temperature = T ambient
Air Pressure = kg/cm²
Density of manometer fluid = m = 1660 kg/m3
Density of water = l = 1000 kg/m3
Density of air = a = 1.205 kg/m3
Viscosity of water (from data book) l = 0.00089 N-s/m2
Viscosity of air (from data book) g = 0.0000192 N-s/m2
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
140
Run No
Air rotameter reading,
Qg, LPM
Water rotameter reading, Ql,
LPM
Manometer reading R,
cm of CCl4
6. Calculations
I.D. of pipe = 0.0254 D, m
Cross sectional area of pipe A = ------- D², = 5.0670 x 10⁻⁴ m²
4
Volumetric flow rate of air = Qg LPM
Volumetric flow rate of Water = Ql , LPM
Air superficial velocity Vg = ((Qg/60) *10-03
)/A, m/s
Water superficial velocity Vl = ((Ql/60) *10-03
)/A, m/s
Air Reynolds number Reg = DVg g / g
Water Reynolds number Rel = DVl l / l
Experimental two phase pressure drop:
Two phase pressure drop Ptp = (R/100 [m-w)* g], N-s
Two phase pressure drop per unit length = (P/Z) tp, N-s/m²/m
Two phase flow friction factor = ftpg or ftpl
ftpl = (P/Z)tp .g. D/(2*Vl2 l)
(based on superficial velocity of liquid)
ftpg = (P/Z)tp .g. D/(2*Vg2 g)
(based on superficial velocity of Gas)
7. Results & Discussion
8. Conclusion
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
141
EXPERIMENT NO. 18
MASS TRANSFER WITH CHEMICAL REACTION
1. Aim
1. To study the dissolution of benzoic acid in aqueous NaOH solution.
2. To compare the observe enhancement factor for mass transfer with those predicted by the
film and boundary layer models.
2. Theory
Solid-liquid mass transfer plays an important role in some industrial operations. The
dissolution may occur with or without chemical reaction. In case dissolution is accompanied
by solid-liquid reaction, it is desirable to know the enhancement in the rate of mass transfer
due to chemical reaction. In the present experiment we aim at finding the enhancement in the
rate of dissolution due to simultaneous reaction and compare it with the enhancement
predicted on the basis of the film and boundary layer models. The system is: dissolution of
benzoic acid in aqueous NaOH solution.
The dissolution of a solid in a solution accompanied with instantaneous chemical reaction can
be expressed as:
BB Product
Where, A is the solid and B is the liquid phase reactant, assuming the reaction to be
instantaneous so that A and B don’t coexist. The mechanism of solid dissolution involves
dissolution of A in liquid followed by its reaction with species B diffusing from the bull
liquid phase at a reaction plane.
If the film model is applied to this situation, the enhancement factor, defined as the ratio of
the solid-liquid mass transfer coefficient with reaction, kr to the mass transfer coefficient
without reaction, k, given by:
A
B
D
D
D
D
k
k
B
0
A
B
B
Arfilm
--------- (1)
And for boundary layer model it is:
A
B
D
D
D
D
k
k
B
o
3/2
A
B
3/1
B
Arh
---------- (2)
3. Experimental Set-up
The Set-up consists of a cylinder of benzoic acid mounted on a SS rod and driven by a D.C.
motor. The operational range of rotation is between 10 to 30 rpm. The cylinder is immersed
in an aqueous solution of sodium hydroxide of known concentration in a 500 ml vessel filled
to 2/3rd
its capacity. The position of the benzoic acid cylinder is so adjusted that the liquid
level rises above the top surface by about 3 cm. The dimensions of the benzoic acid cylinder
may be fixed at diameter: 2 to 3 cm, length: 5 to 7 cm. The cylinder can be prepared by
pouring molten benzoic acid in the mould of desired dimensions with 4 to 5 mm SS rod
located in the center of the mould in a vertical position. User can also use the cylinder
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
142
provided with the set-up.
4. Experimental Procedure
1. Record the dimensions of the benzoic acid cylinder (length and OD of SS rod) and then fix
I in the vertical position with the D.C Motor. (Do not immerse it in solution as yet)
2. Fill the vessel with aqueous NaOH solution of known concentration of 2/3rd
of its volume.
Record the volume of aqueous NaOH solution added (V).
3. Start the water bath and fix the dissolution temperature (ambient to 50 0C), wait till the
aqueous solution attains the desired temperature. Record the temperature (T).
4. Now fix the benzoic acid cylinder inside the vessel containing aqueous NaOH solution and
start the motor at a fixed rotational speed. (N, rpm)
5. Run the experiment for 10 minutes.
6. Stop the motor and remove the benzoic acid cylinder.
7. Mix thoroughly the contents of vessel and analyze it for un-reacted NaOH concentration
by titration against standard HCL solution.
8. Measure the benzoic acid cylinder dimensions again.
9. Repeat steps 1 to 8 for different concentrations of aqueous NaOH solutions.
10. Repeat steps 1 to 8 using de-ionized water. This run may be carried for about 45 to 60
minutes duration. During this period small samples (5 ml) should be withdraw at regular
intervals of 10 minutes and analyzed for dissolved benzoic acid by titration against 0.02
kmol/m3 HCL solution.
5. Observations and Calculations
Reaction:
C6H5COOH + NaOH C6H5COONa + H2O
(For each mole of benzoic acid dissolved, 1 mole of NaOH is consumed)
Thus rate of dissolution can be determined by measuring the fall in NaOH concentration.
1. Recommended concentration range for aqueous NaOH solution: 0.5 kmol/m3 to 1.5
kmol/m3.
2. Use the following standard solutions for titration:
a. 0.02 kmol/m3 NaOH solution for the estimation of dissolved benzoic acid.
b. 0.4 to 1 kmol/m3 standard HCL solution for the estimation of un-reacted NaOH.
3. For each titration in case of estimation of NaOH use 10 ml of solution and titrate against
standard HCL solution using suitable indicator.
4. For each titration in case of estimation of dissolved benzoic acid use 5 ml of solution and
titrate against 0.02 kmol/m3 standard NaOH solution.
Let titer value for sample before the experiment = T1 (m3).
Let titer value for sample after the experiment = T2 (m3).
Let titer value for sample = T3 (m3).
Time of dissolution = t (sec)
Dissolution temp = T oC
Hence,
[NaOH]i = (T1/10) [HCL]
[NaOH]f = (T2/10) [HCL]
[C6H5OOH] = (T3/5) [NaOH]
The rate of dissolution of Benzoic acid:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
143
R = ({[NaOH]i - [NaOH]f}) X Vol. of NaOH sol. in tank (V m3).
Let the average dimensions (avg. of start and of expt.) of benzoic acid cylinder be Dav, Lav.
Let S.S. rod diameter = dr.
Average surface area, As =
22
42 ravavav dDLD
Specific rate of dissolution = R / As (kmol/m2-s)
Ak
Rexp
Where,
A is the solubility of benzoic acid in water (0.0276 kmol/m3)
k is obtained from physical dissolution run (i.e. with plain water)
After integrating the material balance equation for a species, we have:
A
AInt
V
Ak bs 1
Where,
[Ab] is the bulk liquid cone of benzoic acid at time, t, in kmol/m3 and
[A] is the solubility of benzoic acid in water, kmol/m3.
After plotting t vs. ln [1 - Ab / A], we record the slope of the line given by:
Slope = kAs / V; knowing As and V, we get k.
The theoretical values for enhancement factor, for the film model and boundary layer
model is obtained from Eq.1 and Eq.2 respectively.
The diffusivity of benzoic acid, DA, may be obtained from the literature = 1.04 x 10-9
m2/ at
30 oC.
Value of DB may be taken as = 4.1 x 10-9
m2/ at 30
oC.
Compare the theoretical values for with the experimental values and observe that
boundary layer model is more close to the experimental value.
6. Results and Discussion
7. Conclusion
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
144
EXPERIMENT NO. 19
ADSORPTION IN PACKED BED
1. Aim To understand the phenomena of adsorption in packed beds.
2. Objective To determine adsorption isotherm of acetic acid on activated charcoal. To determine the
adsorption constant (k) and the maximum adsorbed substance amount of acetic acid per gram
of charcoal (Amax) of Langmuir isotherm.
3. Theory Adsorption is a process that occurs when a gas or liquid solute accumulates on the surface of
a solid or a liquid (adsorbent), forming a molecular or atomic film (the adsorbate). It is
different from absorption, in which a substance diffuses into a liquid or solid to form a
solution. The term absorption encompasses both processes, while desorption is the reverse
process.
Adsorption is operative in most natural physical, biological, and chemical systems, and is
widely used in industrial applications such as activated charcoal, synthetic resins and water
purification. Similar to surface tension, adsorption is a consequence of surface energy. In a
bulk material, all the bonding requirements (be they ionic, covalent or metallic) of the
constituent atoms of the material are filled. But atoms on the (clean) surface experience a
bond deficiency, because they are not wholly surrounded by other atoms. Thus it is
energetically favorable for them to bond with whatever happens to be available. The exact
nature of the bonding depends on the details of the species involved, but the adsorbed
material is generally classified as exhibiting physisorption or chemisorptions.
Physisorption or physical adsorption is a type of adsorption in which the adsorbate adheres to
the surface only through Van der Waals (weak intermolecular) interactions, which are also
responsible for the non-ideal behavior of real gases.
Chemisorption is a type of adsorption whereby a molecule adheres to a surface through the
formation of a chemical bond, as opposed to the Van der Waals forces which cause
physisorption.
Adsorption is usually described through isotherms, that is, functions which connect the
amount of adsorbate on the adsorbent, with its pressure (if gas) or concentration (if liquid).
One can find in literature several models describing process of adsorption, namely Freundlich
isotherm, Langmuir isotherm, BET isotherm, etc. We will deal with Langmuir isotherm in
more details:
Langmuir isotherm
In 1916, Irving Langmuir published an isotherm for gases adsorbed on solids, which retained
his name. It is an empirical isotherm derived from a proposed kinetic mechanism.
It is based on four hypotheses:
i. The surface of the adsorbent is uniform, that is, all the adsorption sites are equal.
ii. Adsorbed molecules do not interact.
iii. All adsorption occurs through the same mechanism.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
145
iv. At the maximum adsorption, only a monolayer is formed: molecules of adsorption do
not deposit on other, already adsorbed, molecules of adsorbate, only on the free
surface of the adsorbent.
For liquids (adsorbate) adsorbed on solids (adsorbent), the Langmuir isotherm (Fig. 1) can
be expressed by
------------------------ (1)
Where m is the substance amount of adsorbate adsorbed per gram of adsorbent (or kg) of the
unit of m is mol.g-1
.resp. mol. kg-1
Amax is the maximal substance amount per gram (or kg) of the adsorbent.
The unit of Amax is mol.g-1
, resp. mol.kg -1
k is the adsorption constant (mol-1
.dm3), c is the
concentration of adsorbate in liquid (mol.dm-3
).
In practice, activated carbon is used as an adsorbent for the adsorption of mainly organic
compounds along with some larger molecular weight inorganic compounds such as iodine
and mercury.
Activated Carbon - Activated carbon can be manufactured from carbonaceous material,
including coal (bituminous, sub-bituminous, and lignite), peat, wood, or nutshells (i.e.,
coconut).The manufacturing process consists of two phases, carbonization and activation.
The carbonization process includes drying and then heating to separate by-products,
including tars and other hydrocarbons, from the raw material, as well as to drive off any gases
generated. The carbonization process is completed by heating the material at 400–600°C in
an oxygen-deficient atmosphere that cannot support combustion.
4. Experimental Setup The experimental set up consists of a three Glass Columns having different diameter and
height, filled with activated carbon. A common feed inlet (manifold) is provided at the
bottom of each column. Feed is supplied from feed tank by means of pump and rotameter.
Flow rate can be varied by rotameter. A bye-pass arrangement is also provided to maintain
level in feed tank (optional). Adsorption process can be studied by varying bed height and
feed flow rate in each of the three columns turn-wise. The whole set-up is mounted on a
powder coated sturdy MS frame.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
146
Glass Column Borosilicate - ID 28mm height 500 mm, ID 38mm height 500mm and ID
52mm and height 750mm, Rotameter Make Eureka 2-20LPH. Pump make Promivac Model
PMP-15, Max head 2.5 mtrs, RPM 2800, single phase 220 Volts @ 50 Hz, sump tank
capacity 20 ltrs apprx.
Chemicals Required (Not in supply scope):
Acetic acid, NaOH, phenolphthalein indicator, activated charcoal granular form (supplied
with set-up).
5. Experimental Procedure a) First prepare the aqueous solution of acetic acid and water.
b) Switch ON the set up and ensure pump discharge.
c) Set the desired flow rate in Rotameter.
d) Open the feed valve provided at the back of column 1 (a common manifold has been
provided for feed routing to all the three columns).
e) Maintain constant flow rate in Rota meter (in case of fluctuation adjust with valve) after
feed starts to come out from top of column, collect the sample in flask.
f) Add 4-5 drops of phenolphthalein indicator in added in each flask and titrate by
standard NaOH solution.
g) Once the endpoint has been reached, read the burette. The volume of the base 0
iX(ml)
that was required to reach the endpoint.
h) Repeat procedure for different flow rates and bed heights.
i) After completing taking readings of Column 1, start feed supply to column NO 2 and
close feed valve of column NO 1.
j) Repeat procedure from 4-5 as mentioned above for different flow rates and bed heights.
k) After completing taking readings of Column 2, start feed supply to column NO 3 and
close feed valve of column NO 2.
l) After completing experiment switch off pump and disconnect set-up from mains. Drain
the SET-UP.
6. Observations and Calculations
Table 1
Flask
No.
0
iX (ml) 0
ic
(mol/dm3)
Xi
(ml)
ci
(mol/dm3)
mi
(mmol/g)
1/ci
(dm3
/mol)
l/mi
(g/mmol)
1
2
3
4
5
0
ic - Concentration of acetic acid before the adsorption reaction
ci- Concentration of acetic acid after the adsorption reaction
mi- Amount of acetic acid adsorbed per gram of charcoal 0
iX -The volume of the titrant (NaOH)
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
147
6
Determination of the concentration of acetic acid before (ci0) and after (ci) Adsorption:
,0
0
V
cXc Ti
i ------------------------- (2)
Where 0
iX is the volume of the titrant (NaOH), cT is the concentration of the titrant, V is the
volume of the analytic (acetic acid according to Tab. 2), i=1-6 is the number of flask.
Calculate the concentration of acetic acid after adsorption (ci), using the Eq. 2 and data form
Tab. 3 after adsorption.
Determination of the substance amount of acetic acid adsorbed per gram of charcoal (mol.g-
1) in individual flask:
,)( 0
g
Vccm Aii
i
--------------------------- (3)
Where 0
ic , ci are the concentrations of acetic acid before and after adsorption, respectively. VA
is the volume of the liquid phase in the mixture charcoal – acetic Acid, g is the mass of the
adsorbent – charcoal (in grams), i=1-6 is the number of flask.
Eq. 3 supposes that VA is the same for i=1-6, and also the mass of the charcoal (g). Write
down the obtained values of mi to the Tab. 3.
Determination of k and Amax: The Eq. 1 one can rearrange into a form:
,1111
maxmax AcAm k
------------------------ (4)
Thus,
cf
m
11 should be a straight line.
Use MS Excel to create the dependence
cf
m
11, where c is the concentration of acetic acid
after adsorption. Fit the experimental points with a linear function. The slope represents the
value ofkAmax
1, and the intercept corresponds to
max
1
A
Calculate Amax and k from the slope and the intercept.
7. Precautions
i. Do not run the pump at low voltage i.e. less than 180 Volts.
ii. Never fully close the Delivery line fully.
iii. Always keep apparatus free from dust.
iv. To prevent clogging of moving parts, Run Pump at least once in a fortnight.
v. Always use clean water (use distill water if available in lab).
vi. If apparatus will not in use for more than one month, drain the apparatus completely.
vii. If pump gets jam, open the back cover of pump and rotate the shaft manually.
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
148
EXPERIMENT NO. 20
HUMIDIFICATION IN WETTED WALL COLUMN
1. Aim
Humidification & Dehumidification study in wetted wall column.
2. Objective
1. To take, and learn to interpret psychometric (wet and dry bulb) data, and to understand
more
generally what is involved in transferring mass across gas-liquid interfaces.
2. To investigate the effects of air flow rates on the mass transfer coefficient, KG (kg mole of
water transferred /m2.h.atm).
3. Theory
A Wetted Wall Column is essentially a vertical tube with means of admitting liquid at the top
and causing it to flow downwards along the inside wall of the tube, under influence of the
gravity. Gas is admitted to the inside bottom of the tube, where it flows through the tower in
contact with liquid (i.e. water).
The mass transfer coefficient KG can be measured in the equipment in which the area of
contact between the two phases is known and boundary layer separation.
The measured flow of air at a measured humidity is brought in to contact with a film of water
at certain temperature and vapor pressure. Moisture is absorbed in the air from the water film
and the resultant humidity of the air and temperature & vapor pressure of the water at the
entry and exit is measured. The rate of diffusion through the gas film, NA, is given by:
NA = KG A (ΔP)m kg mole/h
Where:
KG = Gas film coefficient, kg mole of water transferred/m2 –h-atm. Partial pressure
difference.
A = wetted surface of column
(ΔP)m = log mean partial pressure driving force across the ends of the column.
4. Experimental Setup
4.1. Schematic Diagram of Experimental Setup
The schematic diagram of the experimental setup is shown below:
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
149
5. Experimental Procedure
b) Feed water to the column from top at a rate at which complete wetting with
minimum ripple formation takes place.
c) Commence and operation with minimum air flow (H =3 cm) and after 10-15 minute
the wet bulb and dry bulb temperature of the inlet air and outlet air at this flow rate
is noted.
d) Read the corresponding humidity (from psychometric chart) and vapor pressure of
water corresponding to the entry and exit temperatures.
e) Repeat step 2 and 3 for 3-4 air flow rates.
f) Calculate experimental value of KG
6. Observations 1. Column diameter, D = 2.54 cm
2. Column effective length, L = 1.04 m
3. Column pressure, P = 760 mmHg/ 1 atm
4. Area for mass transfer A = Dl
= 3.14 2.54 104 = 829.9 cm2
6.1. Observation Table
Air temperature, °C Column Bottom Column Top
Dry bulb
Wet bulb
Air humidity(Kg water/kg dry air) A. HB A.HT
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
150
Water temperature, °C
7. Calculations:
Air temperature, °C Column Bottom Column Top
Dry bulb
Wet bulb
Air humidity(Kg water/kg dry air)
Water temperature, °C
Molar fraction of water in air at bottom, y1 = (A. H.B / 18) / (A. H.B /18 + 1/29)
y1 =
Molar fraction of water in air at top, y2 = (A. H.T / 18) / (A. H.T/18 + 1/29)
y2 =
Vapour pressure of water at inlet temperature, (P2) T = 0.0508 atm (Bhatt & Vora-343 pp.)
Vapour pressure of water at outlet temperature, (P1) B =
(ΔP)m = [( P1sat
-P1)-( P2sat
-P2)]/[ln(P1sat
-P1/P2sat
-P2)
yi= (y1+y2) / 2
yi= (0.02+0.026) / 2= 0.023
KG (ΔP)m *A / V = [1 / (1-yi)]. In [{(yi-y1)/y2-yi)} {(1-y2) / (1-y1)}]
KG(ΔP)m *A/V= X
H = Head of water
P = H (water - air) g=
V = molar flow rate of gas = 0.65. [(2 P)0.5
/ ] =
Where; [Co / (1-)4 =0.65]
m = Vo /4 (do)2 =
V = molar flow rate of gas
V=mass flow rate of air / mol. Wt. of air =
Chemical Engineering Department, Birla Institute of Technology & Science Pilani, Pilani Campus
151
KG = (X * V) / (ΔP)m * A =
Where,
A. H.B= air humidity at bottom
A. H.T= air humidity at top
V = molar flow rate of gas
V0 = mass flow rate of gas
Molar fraction of water in air at bottom=y1, and at top =y2
8. Result & discussions
Hence, the performance of the wetted wall column has been analysed and mass transfer
coefficient is calculated.
Mass Transfer Coefficient of the wetted wall column at flow rate----- is =
9. Conclusion
10. Precautions
1. Do not run the pump with the delivery valve closed for a long time to avoid damage of the
pump.
2. Make sure during the experiment water tank should not be emptied totally.
3. Uniform wetting of the inner surface of the column ensures more valid data.
4. The column will require several minutes to come to steady state, especially with low water
flow rate. Be sure to verify the actual attainment of this condition.
References: 1. Bird R. Stewart W. and Lightfoot E., “Transport Phenomena”, Wiley (2004)
2. Treybal, R. E., Mass Transfer Operations, McGraw Hill Company, New York, 1980
3. McCabe, W. L., Smith J. C., and Harriott, P., Unit Operations of Chemical Engineering, 6th