13
Large Diagnostic Neutral Beam Injectors of Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko
Transcript
Page 1: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

Large Diagnostic Neutral Beam Injectors of Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear PhysicsBudker Institute of Nuclear Physics

Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia

V.Davydenko

Page 2: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

OutlineOutline

RUDI DNBI

W-7X DNBI

H- sources at BINP

Page 3: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

Diagnostic neutral beam injector RUDIDiagnostic neutral beam injector RUDI

ionsou rce

beam line andV-target

TEXTOR

plasm a

deflection m agnet

Vacuu m p um psys tem

neutralizationcham ber

cryopum pscalorim eter

RF s

our

ce

R0

O b se rva tio n p o rts

Page 4: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

RUDI RUDI atat TCVTCV

Page 5: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

1- soft metal case, 2 - gas feeding tube, 3 - inner magnetic shield, 4 - trigger, 5 - ceramic wall, 6 - RF coil, 7 - pull stud (insulator), 8 - ceramic spacers, 9 – beam duct, 10 - water inlet manifold, 11 - grounded grid, 12 - accelerating grid, 13 - extracting grid, 14 - plasma grid, 15 - magnets, 16 - co-axial feedthrough

Eb= 50–53 keV

Ib= 2–2.8 A

T= 2–10 s

δα ≈ 0.5°

F= 4 m

RUDI ion sourceRUDI ion source

Page 6: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

Geometrical beam focusingGeometrical beam focusing

Page 7: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

RUDI grid setRUDI grid set

Page 8: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

CVI 5290 CVI 5290 Ǻ line emission intensity at TEXTORǺ line emission intensity at TEXTOR

Page 9: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

DNBI arrangement atDNBI arrangement at W-7XW-7X

DNBI

Page 10: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

DNBI W-7X ion sourceDNBI W-7X ion source

Eb= 60 keVIb= 10–12 AT=10–60 sF= 6 m

Page 11: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

Electrode of DNBI W-7X ion optical systemElectrode of DNBI W-7X ion optical system

water channels

Page 12: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

HH-- sources at BINP sources at BINP

10 A, 25 keV, 0.01 s pulse H- ion source

15-50 mA, 30 keV DC H- ion sources

The beams can be accelerated up to 150-200 keV

Page 13: Large Diagnostic Neutral Beam Injectors of Budker Institute of Nuclear Physics Budker Institute of Nuclear Physics, 630090, Novosibirsk, Russia V.Davydenko.

SummarySummary

BINP is ready to participate in ITER DNBI development


Recommended