6 Physics’ Best April 2016 © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
L A S E R
Laser-induced breakdown spec-troscopy (LIBS) is an atomic-emis-sion spectroscopy technique that enables rapid chemical analysis of a wide range of materials, in-cluding metals, semiconductors, glasses, biological tissues, plastics, soils, thin paint coatings, and elec-tronic materials.
T he LIBS technique has gained increased interest in recent
years as a result of the development of more compact systems that enable infield use and the construction of tools for online material analysis. This development has been made possible by the increased availability of more compact and industrialgrade system components, including lasers and spectrometers.
A recent study conducted by the Swedish national research labs Acreo Swedish ICT and Swerea KIMAB, in collaboration with laser manufacturer Cobolt AB, exemplifies this trend and shows how a new class of compact, industrialgrade lasers with multikilohertz pulserepetition rates enables significant reduction of the footprint of a LIBS system and opens new opportunities for the use of LIBS
to improve efficiency in industrial processes, such as sorting of metals for recycling. The compact pulsed diodedpumped solidstate (DPSS) laser used in the study gives nice LIBS sig nals on dirty scrap parts of Al with penetration depths of > 50 µm at a peak power density of 3.5 GW/cm2.
The major strength of the LIBS technique is its ability to perform fast and remote chemical analysis to determine the elemental composition of the tested samples without the need of any sample preparation. The LIBS technique relies on focusing short, highenergy laser pulses onto the surface of a target sample to generate a plasma consisting of
small amounts of ab lated material (Fig. 1).
The extremely high temperatures within the early plasma (more than 100 000 K) cause the ablated material to dissociate into excited atomic and ionic species; as the plasma cools, the characteristic atomic emission lines can be detected by a spectrograph. The method enables fast and sensitive chemical analysis of, in principle, any kind of matter (solid, liquid, or gas).
Detection limits are typically in the low parts per million for heavymetal elements. Sample preparation is normally not necessary and the method is also considered essentially nondestructive as only a small amount of the material is removed. Other advantages of LIBS are its ability to provide depth profiles and to remove surface contamination.
LIBS is an attractive technique for a wide range of scientific and industrial analytical applications, including metalcontent analysis, solar silicon quality control, plant and soil analysis, mining and prospecting, forensic and biomedical studies, and explosives and biological warfare detection. Its potential use in tools for online monitoring of industrial processes is particularly interesting, especially for the metal industry. For example, LIBS can
Bertrand Noharet, Tania Irebo, Swerea KIMAB, Kista, Swe-den; Carola Sterner, Acreo Swedish ICT, Kista, Sweden; Mikael Ek, Håkan Karlsson, Cobolt AB, Solna, Sweden
Improved Metal RecyclingIndustrial processes based on laser induced breakdown spectroscopy (LIBS) can benefit from the use of compact high-repetition-rate solid-state lasers.
Bertrand Noharet, Tania Irebo, Carola Sterner, Mikael Ek and Håkan Karlsson
Fig. 1 Schematic illustration of a typical LIBS setup
Laser Sample
Focusing lens
Optical fiber
Collecting optics
ComputerCCD Spectrometer
Fig. 2 The Cobolt Tor is a compact, high-repetition-rate 1064 nm or 532 nm laser system.
be applied to monitor and optimize critical metallurgical processes (slag or molten metal analysis), to control the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort metal scrap before recycling.
Lasers for LIBS
Most laboratory LIBS setups have traditionally been based on flashlamppumped Qswitched Nd:YAG lasers that deliver pulses with energies of hundreds of millijoules in short pulse widths ( to 5 ns) at relatively low pulserepetition rates, typically 10 to 30 Hz. More recently, industrial fiber lasers have been shown to provide good results in generating plasmas with millijoule pulses of slightly longer pulse widths (10 ns) and with multikilohertz pulse rates [1]. However, a major drawback of these laser sources is their large size and high power consumption.
Although highpulseenergy lasers perform well in many scientific LIBS applications, it has become understood from research over the last decade that the generation and properties of the plasma are affected not only by the pulse energy, but also by the laser pulse width, repetition rate, and wavelength [2 – 4]. It is also clear that another important attribute of the laser is its beam quality, as this parameter affects the power density at the sample. These new understandings encourage the use of other types of LIBS laser sources that have a slightly different set of performance parameters and a much more compact format.
A compact LIBS set-up
With the purpose of developing a LIBS system that could meet the requirements on robustness and compact size for use in industrial applications such as aluminum recycling, researchers at Acreo and KIMAB integrated a Cobolt Tor laser from Cobolt AB in their LIBS setup as an alternative to the highpulseenergy, lowrepetitionrate
Nd:YAG laser previously used. The Cobolt Tor laser represents a new class of compact, highperformance diodepumped Qswitched lasers that can help advance the trend of extending the use of LIBS systems from laboratory work to industrial applications (Fig. 2).
The laser design provides a combination of stable multikilohertz repetition rate greater than kHz with less than 1 µs pulsetopulse jitter (Fig. ), pulse energies in the 100 µJ range at 10 nm, pulse widths of a few nanoseconds, and a high beam quality (M2 < 1.3). A key advantage of the laser is its substantially more compact size compared to traditional highpulseenergy Nd:YAG lasers. The laser head measures 15 × 0 × 5 mm and is accompanied by an electronics unit measuring 10 × × mm. Typical heat load of the laser head is less than 30 W which, when combined with the small size, allows for compact integration into portable industrial LIBS systems. The laser is manu factured into hermetically sealed packages that have proven insen sitive to 0 G mechanical shocks and repeated thermal cycling over –30 to 0 oC. The thermomechanical stability of the packages ensures robust performance and long lifetime of the laser in varying ambient conditions as they exist in demanding industrial applications.
The LIBS setup in this work involved a Cobolt Tor pulsed laser (10 nm, kHz, ns, 150 µJ), with a focal length of 50 cm to focus the laser beam onto the sample to create a plasma, and collecting optics to transport the emitted plasma light to a compact spectrometer (the HR000+ made by Ocean Optics, Dunedin, FL).
Experimental results
A first round of experiments was conducted on aluminum reference samples to investigate the capability of the setup to classify different aluminum alloys with good confidence. It was found that the high repetition rate Cobolt Tor laser
Stent Scanner SystemQuality controlof medical implantsof medical implants
Stent Scanner System
of medical implants
Application
Schäfter+Kirchhoff develop and manufacture laser sources, line scan camera systems and fiber optic products for world-wide distribution and use.
[email protected] www.SuKHamburg.com
Laser Line, Micro Focus,Laser Pattern Generators
Wavelengths 405 – 2050 nm
Application
Laser Pattern GeneratorsWavelengths 405 – 2050 nm
Application
Application
400 500 700 800600Wavelength (nm)
0
Resp
on
sitivi
ty(V
/mJ/c
m2
)
100
0.0
1.0
400 500 600Wavelength (nm)
Rela
tive
sen
sitv
ity
monochrome
0.0400 600
Wavelength (nm)800 1000
Spectralrange
Spectralrange
TM
USB 3.0
Line Scan Cameras 512 to 8160 pixels. Color, monochrome, or TDi sensors.
www.SuKHamburg.com/linescan
monochrome
USB
Interfaces: SK 9170: Gray Scale Line Signal – 0
SK 9170: Gray Scale Line Signal – 1
255
255
00
00
ZOOM
ZOOM
monochrome
SK 9170: Gray Scale Line Signal – 1
ZOOM255
00
Interface:Power supply via USB
Application:
Adjustment of left- and right-
handed cir cular zation.
USB 2.0Power supply via USB
Adjustment of left-Adjustment of left-Adjustment of left-Adjustment of left-
Power supply Power supply via USBPower supply via USBPower supply Power supply via USBvia USB
Application:
Fiber Input Connector
Measurement of re-sulting Polarization
Extinction RatioConnector
key
Bad
Connector key
Good
Polarization Alignment
Measurement System
Polarization Analyzer Series SK010PA-...Interface: USB 2.0 · Multiple Wavelength Ranges 350 – 1600nm
Standard fiber
RGBVPM-Fiber
with End Caps
Reduced power den-sity at fiber end-face
( factor 100 )
Fiber collimator 60FC-...
Amagnetic (Titanium) Fiber Connectors and
Fiber Optic Components
Laser Beam Coupler 60SMS-1-4-…
PM-Fiber
NEW
Fiber Optic Components and Fiber Coupled Laser Sourcespolarization maintaining for wavelengths 370 – 1700nm
Apochromatic fiber
405 460 532 633
405 460
RGBV
Fiber collimator 60FC-...
Amagnetic (Titanium) Fiber Connectors and
Fiber Optic Components
VVV
inclined fiber coupling axis
Laser Beam Coupler
Apochromatic fiber Apochromatic fiber RRGGB
inclined fiber inclined fiber coupling axiscoupling axis
AZ_PhysicsBest_86mm_April-2016_V2.indd 1 17.03.2016 18:00:21
Physics’ Best April 2016 © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim
L A S E R
power density per pulse can be estimated to 3.5 GW/cm2.
The strong performance of this compact highrepetitionrate laser in LIBS applications is most likely related to its good beam quality and short pulse length which enable high peak power density. Additionally, its relatively lowener gy pulses create shortlived continuum plasma backgrounds which allows the use of nongated detectors for quantitative analysis, simplifying the detector requirements and system cost. The high repetition rate of the laser also helps to enhance the signaltonoise ratio at the detector level. Moreover, the high repetition rate and low pulsetopulse jitter enable rapid scanning along a sample and allow for synchronized gating of the detection system which could lead to even lower detection limits.
Conclusion
The LIBS technique has great potential as an analytical tool for improving industrial processes such as online scrap metal sorting for more efficient recycling. The results presented show that compact highrepetitionrate pulsed lasers with good beam quality can provide highquality LIBS results while drastically reducing the system size allowing the integration into portable LIBS systems suitable for the use in industrial environments.
generated highquality LIBS spectra with good signaltonoise ratios. All the alloying elements that are critical for aluminum scrap classification can be clearly quantified (Fig. ).
Encouraged by the promising results on reference samples, experiments with dirty scrap samples col lected at scrapyards were conducted to confirm the practical applicability of a LIBS system based on this compact highrepetitionrate laser. The system was proven to be capable of clearly resolving the elemental composition of various alloys also from dirty scrap samples, as evidenced by the two spectra presented in Fig. . By optimizing the laser and collecting optics, it was possible to achieve goodquality LIBS signals at free distances of more than 50 cm. In a continued investigation, LIBS plasma were taken on polished samples of Al, in order to study the ablation profiles generated with
the Cobolt Tor kHz repetition rate laser. The laser was applied to the sample surface as a single burst of a predefined number of pulses. The generated ablation craters were imaged by Scanning Electron Microscopy (SEM) and their depth profiles measured by a confocal microscope setup (Fig. ). The results show that the ablation depth increases from about 1 µm at 100 pulses (0 ms burst) to about 50 µm at 00 pulses (0 ms burst) which is usually more than enough to penetrate through layers of oxide or paint on the sample surface. The ablation depth is believed to increase even further up to a burston time of around 1 s where the plasma starts to fade. However, as the crater diameter appears to remain the same also for longer pulse bursts, the depth profile becomes too narrow and too deep to be measured in the confocal setup. From the measured crater diameter of about 0 µm, the optical peak
Fig. A measured pulse train for a Cobolt Tor 1064 nm laser operating at a repetiti-on rate of kHz.
Fig. LIBS data from an aluminum reference sample collected using a Cobolt Tor high repetition rate pulsed DPSS laser.
a
wavelength in nm
AI
Inte
nsity
220 240 260 280 300 320 340 360 380 400 420
AI
AI
Mg
Mg
Si CuZn
© 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim Physics’ Best April 2016
L A S E R
[] L. Radziemski and D. Cremers, Spectrochimica Acta Part B 87, 3 (013)
[3] R. Ahmed and M. Aslam Baig, J. Appl. Phys. 106, 03330 (00)
[] J. D. Winefordner et al., J. Anal. At. Spectrom. 19, 101 (00)
[5] B. Noharet et al., SPIE Photonics West 8992, 0R1 (01)
AcknowledgmentsThis work has been conducted with help of Acreo Swedish ICT and Swerea KIMAB. Special thanks to Håkan Toors and Fredrik Lindberg at KIMAB who helped generating SEM images and confocal measurements of the ablation depth profiles.
[1] M. Scharun et al., Spectrochimica Acta Part B 87, 1 (013)
Fig. LIBS data obtained for two dif-ferent scrap samples representing diffe-
rent aluminum alloys with different material compositions.
a 0,1
8000
7000
6000
5000
4000
3000
2000
1000
0
wavelength in nm
Sample 2Sample 1
220 240 260 280 300 320 340 360 380 400 420 440
Inte
nsity
Mg
Mg
AI
AI AIAI
Cu Cu
AI
AI
Fig. SEM images and depth profiles of ablation craters generated on Al sam-ples with the Cobolt Tor laser in burst-
mode: burst of 100 pulses (a) and burst of 200 pulses (b).
–40 –20 0 20 40 –40 –20 0 20 40µmµm
20
0
–20
–40
–60
20
0
–20
–40
–60
µm µm
50 YEARS OF LEAK DETECTION
Are you looking for a perfect vacuum solution? Please contact us:
Pfeiffer Vacuum GmbHHeadquarters/GermanyT +49 6441 802-0F +49 6441 [email protected] www.pfeiffer-vacuum.com
Experience makes sense!
Pfeiffer Vacuum is the supplier with the widest range of leak detectors on the market. We provide solutions for applications using helium and hydrogen as tracer gas.
From portable devices to complex leak detection systems – we always offer the optimum solution to detect leakages in many different industrial sectors.
Competence, quality and service from a single source.
16.03.22_PhysikJournal_Sonderausg_LecksucherJub_52x260mm_EN.indd 122.03.16 15:02