6 Physics’ Best April 2016 © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim LASER Laser-induced breakdown spec- troscopy (LIBS) is an atomic-emis- sion spectroscopy technique that enables rapid chemical analysis of a wide range of materials, in- cluding metals, semiconductors, glasses, biological tissues, plastics, soils, thin paint coatings, and elec- tronic materials. T he LIBS technique has gained increased interest in recent years as a result of the development of more compact systems that en- able in-field use and the construc- tion of tools for on-line material analysis. This development has been made possible by the increased availability of more compact and in- dustrial-grade system components, including lasers and spectrometers. A recent study conducted by the Swedish national research labs Acreo Swedish ICT and Swerea KIMAB, in collaboration with laser manufacturer Cobolt AB, exem- plifies this trend and shows how a new class of compact, industrial- grade lasers with multikilohertz pulse-repetition rates enables sig- nificant reduction of the footprint of a LIBS system and opens new opportunities for the use of LIBS to improve efficiency in industrial processes, such as sorting of metals for recycling. The compact pulsed dioded-pumped solid-state (DPSS) laser used in the study gives nice LIBS signals on dirty scrap parts of Al with penetration depths of > 50 µm at a peak power density of 3.5 GW/cm 2 . The major strength of the LIBS technique is its ability to perform fast and remote chemical analysis to determine the elemental compo- sition of the tested samples without the need of any sample preparation. The LIBS technique relies on focu- sing short, high-energy laser pulses onto the surface of a target sample to generate a plasma consisting of small amounts of ablated material (Fig. 1). The extremely high tempera- tures within the early plasma (more than 100 000 K) cause the ablated material to dissociate into excited atomic and ionic species; as the plasma cools, the characteristic ato- mic emission lines can be detected by a spectrograph. The method enables fast and sensitive chemical analysis of, in principle, any kind of matter (solid, liquid, or gas). Detection limits are typically in the low parts per million for heavy- metal elements. Sample preparation is normally not necessary and the method is also considered essen- tially nondestructive as only a small amount of the material is removed. Other advantages of LIBS are its ability to provide depth profiles and to remove surface contamination. LIBS is an attractive technique for a wide range of scientific and industrial analytical applications, including metal-content analysis, solar silicon quality control, plant and soil analysis, mining and pro- specting, forensic and biomedical studies, and explosives and biologi- cal warfare detection. Its potential use in tools for on-line monitoring of industrial processes is particular- ly interesting, especially for the me- tal industry. For example, LIBS can Bertrand Noharet, Tania Irebo, Swerea KIMAB, Kista, Swe- den; Carola Sterner, Acreo Swedish ICT, Kista, Sweden; Mikael Ek, Håkan Karlsson, Cobolt AB, Solna, Sweden Improved Metal Recycling Industrial processes based on laser induced breakdown spectroscopy (LIBS) can benefit from the use of compact high-repetition-rate solid-state lasers. Bertrand Noharet, Tania Irebo, Carola Sterner, Mikael Ek and Håkan Karlsson Fig. 1 Schematic illustration of a typical LIBS setup Laser Sample Focusing lens Optical fiber Collecting optics Computer CCD Spectrometer Fig. 2 The Cobolt Tor is a compact, high-repetition-rate 1064 nm or 532 nm laser system.
Transcript
Page 1: LASER Improved Metal Recycling - HÜBNER Photonics · or molten metal analysis), to con trol the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort

6 Physics’ Best April 2016 © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

L A S E R

Laser-induced breakdown spec-troscopy (LIBS) is an atomic-emis-sion spectroscopy technique that enables rapid chemical analysis of a wide range of materials, in-cluding metals, semiconductors, glasses, biological tissues, plastics, soils, thin paint coatings, and elec-tronic materials.

T he LIBS technique has gained increased interest in recent

years as a result of the development of more compact systems that en­able in­field use and the construc­tion of tools for on­line material analysis. This development has been made possible by the increased availability of more compact and in­dustrial­grade system components, including lasers and spectrometers.

A recent study conducted by the Swedish national research labs Acreo Swedish ICT and Swerea KIMAB, in collaboration with laser manufacturer Cobolt AB, exem­plifies this trend and shows how a new class of compact, industrial­grade lasers with multikilohertz pulse­repetition rates enables sig­nificant reduction of the footprint of a LIBS system and opens new opportunities for the use of LIBS

to improve efficiency in industrial processes, such as sorting of metals for recycling. The compact pulsed dioded­pumped solid­state (DPSS) laser used in the study gives nice LIBS sig nals on dirty scrap parts of Al with penetration depths of > 50 µm at a peak power density of 3.5 GW/cm2.

The major strength of the LIBS technique is its ability to perform fast and remote chemical analysis to determine the elemental compo­sition of the tested samples without the need of any sample preparation. The LIBS technique relies on focu­sing short, high­energy laser pulses onto the surface of a target sample to generate a plasma consisting of

small amounts of ab lated material (Fig. 1).

The extremely high tempera­tures within the early plasma (more than 100 000 K) cause the ablated material to dissociate into excited atomic and ionic species; as the plasma cools, the characteristic ato­mic emission lines can be detected by a spectrograph. The method enables fast and sensitive chemical analysis of, in principle, any kind of matter (solid, liquid, or gas).

Detection limits are typically in the low parts per million for heavy­metal elements. Sample preparation is normally not necessary and the method is also considered essen­tially nondestructive as only a small amount of the material is removed. Other advantages of LIBS are its ability to provide depth profiles and to remove surface contamination.

LIBS is an attractive technique for a wide range of scientific and industrial analytical applications, including metal­content analysis, solar silicon quality control, plant and soil analysis, mining and pro­specting, forensic and biomedical studies, and explosives and biologi­cal warfare detection. Its potential use in tools for on­line monitoring of industrial processes is particular­ly interesting, especially for the me­tal industry. For example, LIBS can

Bertrand Noharet, Tania Irebo, Swerea KIMAB, Kista, Swe-den; Carola Sterner, Acreo Swedish ICT, Kista, Sweden; Mikael Ek, Håkan Karlsson, Cobolt AB, Solna, Sweden

Improved Metal RecyclingIndustrial processes based on laser induced breakdown spectroscopy (LIBS) can benefit from the use of compact high-repetition-rate solid-state lasers.

Bertrand Noharet, Tania Irebo, Carola Sterner, Mikael Ek and Håkan Karlsson

Fig. 1 Schematic illustration of a typical LIBS setup

Laser Sample

Focusing lens

Optical fiber

Collecting optics

ComputerCCD Spectrometer

Fig. 2 The Cobolt Tor is a compact, high-repetition-rate 1064 nm or 532 nm laser system.

Page 2: LASER Improved Metal Recycling - HÜBNER Photonics · or molten metal analysis), to con trol the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort

be applied to monitor and optimize critical metallurgical processes (slag or molten metal analysis), to con­trol the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort metal scrap before recycling.

Lasers for LIBS

Most laboratory LIBS set­ups have traditionally been based on flashlamp­pumped Q­switched Nd:YAG lasers that deliver pulses with energies of hundreds of milli­joules in short pulse widths ( to 5 ns) at relatively low pulse­repe­tition rates, typically 10 to 30 Hz. More recently, industrial fiber lasers have been shown to provide good results in generating plasmas with millijoule pulses of slightly longer pulse widths (10 ns) and with multi­kilohertz pulse rates [1]. However, a major drawback of these laser sources is their large size and high power consumption.

Although high­pulse­energy la­sers perform well in many scientific LIBS applications, it has become understood from research over the last decade that the generation and properties of the plasma are affec­ted not only by the pulse energy, but also by the laser pulse width, re­petition rate, and wavelength [2 – 4]. It is also clear that another impor­tant attribute of the laser is its beam quality, as this parameter affects the power density at the sample. These new understandings encourage the use of other types of LIBS laser sources that have a slightly different set of performance parameters and a much more compact format.

A compact LIBS set-up

With the purpose of developing a LIBS system that could meet the requirements on robustness and compact size for use in industrial applications such as aluminum recycling, researchers at Acreo and KIMAB integrated a Cobolt Tor laser from Cobolt AB in their LIBS set­up as an alternative to the high­pulse­energy, low­repetition­rate

Nd:YAG laser previously used. The Cobolt Tor laser represents a new class of compact, high­performance diode­pumped Q­switched lasers that can help advance the trend of extending the use of LIBS systems from laboratory work to industrial applications (Fig. 2).

The laser design provides a com­bination of stable multikilohertz repetition rate greater than kHz with less than 1 µs pulse­to­pulse jitter (Fig. ), pulse energies in the 100 µJ range at 10 nm, pulse widths of a few nanoseconds, and a high beam quality (M2 < 1.3). A key advantage of the laser is its substan­tially more compact size compared to traditional high­pulse­energy Nd:YAG lasers. The laser head measures 15 × 0 × 5 mm and is accompanied by an electronics unit measuring 10 ×  ×  mm. Typical heat load of the laser head is less than 30 W which, when combined with the small size, al­lows for compact integration into portable industrial LIBS systems. The laser is manu factured into hermetically sealed packages that have proven insen sitive to 0 G mechanical shocks and repeated thermal cycling over –30 to 0 oC. The thermo­mechanical stability of the packages ensures robust perfor­mance and long lifetime of the laser in varying ambient conditions as they exist in demanding industrial applications.

The LIBS set­up in this work involved a Cobolt Tor pulsed laser (10 nm, kHz, ns, 150 µJ), with a focal length of 50 cm to focus the laser beam onto the sample to create a plasma, and collecting op­tics to transport the emitted plasma light to a compact spectrometer (the HR000+ made by Ocean Optics, Dunedin, FL).

Experimental results

A first round of experiments was conducted on aluminum reference samples to investigate the capability of the set­up to classify different aluminum alloys with good confi­dence. It was found that the high repetition rate Cobolt Tor laser

Stent Scanner SystemQuality controlof medical implantsof medical implants

Stent Scanner System

of medical implants

Application

Schäfter+Kirchhoff develop and manufacture laser sources, line scan camera systems and fiber optic products for world-wide distribution and use.

[email protected] www.SuKHamburg.com

Laser Line, Micro Focus,Laser Pattern Generators

Wavelengths 405 – 2050 nm

Application

Laser Pattern GeneratorsWavelengths 405 – 2050 nm

Application

Application

400 500 700 800600Wavelength (nm)

0

Resp

on

sitivi

ty(V

/mJ/c

m2

)

100

0.0

1.0

400 500 600Wavelength (nm)

Rela

tive

sen

sitv

ity

monochrome

0.0400 600

Wavelength (nm)800 1000

Spectralrange

Spectralrange

TM

USB 3.0

Line Scan Cameras 512 to 8160 pixels. Color, monochrome, or TDi sensors.

www.SuKHamburg.com/linescan

monochrome

USB

Interfaces: SK 9170: Gray Scale Line Signal – 0

SK 9170: Gray Scale Line Signal – 1

255

255

00

00

ZOOM

ZOOM

monochrome

SK 9170: Gray Scale Line Signal – 1

ZOOM255

00

Interface:Power supply via USB

Application:

Adjustment of left- and right-

handed cir cular zation.

USB 2.0Power supply via USB

Adjustment of left-Adjustment of left-Adjustment of left-Adjustment of left-

Power supply Power supply via USBPower supply via USBPower supply Power supply via USBvia USB

Application:

Fiber Input Connector

Measurement of re-sulting Polarization

Extinction RatioConnector

key

Bad

Connector key

Good

Polarization Alignment

Measurement System

Polarization Analyzer Series SK010PA-...Interface: USB 2.0 · Multiple Wavelength Ranges 350 – 1600nm

Standard fiber

RGBVPM-Fiber

with End Caps

Reduced power den-sity at fiber end-face

( factor 100 )

Fiber collimator 60FC-...

Amagnetic (Titanium) Fiber Connectors and

Fiber Optic Components

Laser Beam Coupler 60SMS-1-4-…

PM-Fiber

NEW

Fiber Optic Components and Fiber Coupled Laser Sourcespolarization maintaining for wavelengths 370 – 1700nm

Apochromatic fiber

405 460 532 633

405 460

RGBV

Fiber collimator 60FC-...

Amagnetic (Titanium) Fiber Connectors and

Fiber Optic Components

VVV

inclined fiber coupling axis

Laser Beam Coupler

Apochromatic fiber Apochromatic fiber RRGGB

inclined fiber inclined fiber coupling axiscoupling axis

AZ_PhysicsBest_86mm_April-2016_V2.indd 1 17.03.2016 18:00:21

Page 3: LASER Improved Metal Recycling - HÜBNER Photonics · or molten metal analysis), to con trol the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort

Physics’ Best April 2016 © 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim

L A S E R

power density per pulse can be esti­mated to 3.5 GW/cm2.

The strong performance of this compact high­repetition­rate laser in LIBS applications is most likely related to its good beam quality and short pulse length which enable high peak power density. Addi­tionally, its relatively low­ener gy pulses create short­lived continuum plasma backgrounds which allows the use of non­gated detectors for quantitative analysis, simplifying the detector requirements and sys­tem cost. The high repetition rate of the laser also helps to enhance the signal­to­noise ratio at the detector level. Moreover, the high repeti­tion rate and low pulse­to­pulse jitter enable rapid scanning along a sample and allow for synchronized gating of the detection system which could lead to even lower de­tection limits.

Conclusion

The LIBS technique has great potential as an analytical tool for improving industrial processes such as on­line scrap metal sorting for more efficient recycling. The re­sults presented show that compact high­repetition­rate pulsed lasers with good beam quality can pro­vide high­quality LIBS results while drastically reducing the system size allowing the integration into porta­ble LIBS systems suitable for the use in industrial environments.

generated high­quality LIBS spectra with good signal­to­noise ratios. All the alloying elements that are critical for aluminum scrap classi­fication can be clearly quantified (Fig. ).

Encouraged by the promising results on reference samples, expe­riments with dirty scrap samples col lected at scrapyards were con­ducted to confirm the practical applicability of a LIBS system based on this compact high­repetition­rate laser. The system was proven to be capable of clearly resolving the elemental composition of va­rious alloys also from dirty scrap samples, as evidenced by the two spectra presented in Fig. . By op­timizing the laser and collecting optics, it was possible to achieve good­quality LIBS signals at free distances of more than 50 cm. In a continued investigation, LIBS plasma were taken on polished samples of Al, in order to study the ablation profiles generated with

the Cobolt Tor  kHz repetition rate laser. The laser was applied to the sample surface as a single burst of a pre­defined number of pulses. The generated ablation craters were imaged by Scanning Electron Microscopy (SEM) and their depth profiles measured by a confocal microscope set­up (Fig. ). The results show that the ablation depth increases from about 1 µm at 100 pulses (0 ms burst) to about 50 µm at 00 pulses (0 ms burst) which is usually more than enough to penetrate through layers of oxide or paint on the sample surface. The ablation depth is believed to increase even further up to a burst­on time of around 1 s where the plasma starts to fade. However, as the crater diameter appears to remain the same also for longer pulse bursts, the depth profile be­comes too narrow and too deep to be measured in the confocal set­up. From the measured crater diameter of about 0 µm, the optical peak

Fig. A measured pulse train for a Cobolt Tor 1064 nm laser operating at a repetiti-on rate of kHz.

Fig. LIBS data from an aluminum reference sample collected using a Cobolt Tor high repetition rate pulsed DPSS laser.

a

wavelength in nm

AI

Inte

nsity

220 240 260 280 300 320 340 360 380 400 420

AI

AI

Mg

Mg

Si CuZn

Page 4: LASER Improved Metal Recycling - HÜBNER Photonics · or molten metal analysis), to con trol the quality of metal products (rolls, tubes, foils, and so on), or to analyze and sort

© 2016 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim Physics’ Best April 2016

L A S E R

[] L. Radziemski and D. Cremers, Spectro­chimica Acta Part B 87, 3 (013)

[3] R. Ahmed and M. Aslam Baig, J. Appl. Phys. 106, 03330 (00)

[] J. D. Winefordner et al., J. Anal. At. Spectrom. 19, 101 (00)

[5] B. Noharet et al., SPIE Photonics West 8992, 0R­1 (01)

AcknowledgmentsThis work has been conducted with help of Acreo Swedish ICT and Swerea KIMAB. Special thanks to Håkan Toors and Fredrik Lindberg at KIMAB who helped generating SEM images and confocal measure­ments of the ablation depth profiles.

[1] M. Scharun et al., Spectrochimica Acta Part B 87, 1 (013)

Fig. LIBS data obtained for two dif-ferent scrap samples representing diffe-

rent aluminum alloys with different material compositions.

a 0,1

8000

7000

6000

5000

4000

3000

2000

1000

0

wavelength in nm

Sample 2Sample 1

220 240 260 280 300 320 340 360 380 400 420 440

Inte

nsity

Mg

Mg

AI

AI AIAI

Cu Cu

AI

AI

Fig. SEM images and depth profiles of ablation craters generated on Al sam-ples with the Cobolt Tor laser in burst-

mode: burst of 100 pulses (a) and burst of 200 pulses (b).

–40 –20 0 20 40 –40 –20 0 20 40µmµm

20

0

–20

–40

–60

20

0

–20

–40

–60

µm µm

50 YEARS OF LEAK DETECTION

Are you looking for a perfect vacuum solution? Please contact us:

Pfeiffer Vacuum GmbHHeadquarters/GermanyT +49 6441 802-0F +49 6441 [email protected] www.pfeiffer-vacuum.com

Experience makes sense!

Pfeiffer Vacuum is the supplier with the widest range of leak detectors on the market. We provide solutions for applications using helium and hydrogen as tracer gas.

From portable devices to complex leak detection systems – we always offer the optimum solution to detect leakages in many different industrial sectors.

Competence, quality and service from a single source.